A simple, specific and sensitive liquid chromatographic method has been developed for the assay of ketorolac in human plasma and urine. The clean-up of plasma and urine samples were carried out by protein precipitation procedure and liquid–liquid extraction, respectively. Separation was performed by a Waters sunfire C18 reversed-phase column maintained at 35 °C. The mobile phase was a mixture of 0.02 M phosphate buffer (pH adjusted to 4.5 for plasma samples and to 3.5 for urine samples) and acetonitrile (70:30, v/v) at a flow rate of 1.0 mL min−1. The UV detector was set at 315 nm. Nevirapine was used as an internal standard in the assay of urine sample. The method was validated over the concentration range of 0.05–8 and 0.1–10 μg mL−1 for ketorolac in human plasma and urine, respectively. The limits of detection were 0.02 and 0.04 μg mL−1 for plasma and urine estimation at a signal-to-noise ratio of 3. The limits of quantification were 0.05 and 0.1 μg mL−1 for plasma and urine, respectively. The extraction recoveries were found to be 99.3 ± 4.2 and 80.3 ± 3.7% for plasma and urine, respectively. The intra-day and inter-day standard deviations were less than 0.5. The method indicated good performance in terms of specificity, linearity, detection and quantification limits, precision and accuracy. This assay demonstrated to be applicable for clinical pharmacokinetic studies.
相似文献A simple, sensitive, and validated liquid chromatographic method has been developed for the determination of tectorigenin in rat plasma and application to a pharmacokinetic study after oral administration of tectorigenin or its prodrug tectoridin. The analysis was performed on a Kromasil C18 analytical column using gradient elution with acetonitrile 0.1% phosphonic acid water at 0.8 mL min−1. The detection wavelength for UV detection was set at 264 nm. The established method was fully validated with parameters as follows: the intra- and inter-day assay precisions (CV) of three analytes were in the range of 4.2–13.3% and accuracies were between 98.0 and 107.5%; the calibration curve was linear with r 2 > 0.99 over a concentration range of 0.02–2 μg mL−1; the lower limit of quantification was 0.02 μg mL−1; tectorigenin showed stable in rat plasma after 12 h incubation at room temperature, 15 days storage at −80 °C and three freeze/thaw cycles, as well as in reconstitute buffer for 24 h at 25 °C; and the mean recoveries of tectorigenin were 92.3 ± 3.2, 95.5 ± 2.9 and 94.5 ± 3.0% with quality control levels of 0.02, 0.2 and 2 μg mL−1, respectively. In conclusion, this method is simple, economic, and sensitive enough for in vivo pharmacokinetic studies of tectorigenin.
相似文献A stereoselective liquid chromatographic method to determine the enantiomers of ornidazole in human plasma and urine has been developed and validated. After addition of the internal standard (naproxen), samples were acidified and extracted with diethyl ether. The separation was performed on a Chiralcel OB-H column, using hexane-ethanol- glacial acetic acid (94:6:0.08, v/v) as the mobile phase. The method was validated for specificity, linearity, sensitivity, precision, accuracy and stability. For each enantiomer of ornidazole, linear calibration curves were obtained over the concentration range of 0.16–20 μg mL−1 in plasma and 0.32–20 μg mL−1 in urine. For both enantiomers of ornidazole in plasma and urine, the coefficient of variation for precision were consistently less than 12% and accuracy were within ±14% in terms of relative error. Application of the method to a preliminary pharmacokinetic study showed that this validated method was qualified for the direct determination of ornidazole enantiomers in human plasma and urine.
相似文献Taurine is an amino acid which is not incorporated into proteins but found in the cytosol of many mammalian cells, in high concentrations (2–30 mM). Increase in plasma taurine concentration has already been reported after surgical trauma, X-radiation, muscle necrosis, carbon tetrachloride-induced liver damage, and paracetamol overdose. Plasma taurine concentration was measured using LC with fluorescence detection following derivatization by o-phtalaldehyde plus 3-mercapto-propionic acid and α-aminobutyric acid as internal standard. Under these conditions the retention time of taurine was 10 min. This method was sensitive enough, to quantify 150 pg mL−1 and detect 50 pg mL−1 of taurine ranging normally between 65 and 179 mmol L−1 (8–22 μg mL−1). The validated method allowed simple determination of human plasma taurine in pharmacokinetic and biomarker studies.
相似文献A high-performance liquid chromatography-electrospray ionization-mass spectromentry (LC–ESI–MS) method has been developed for the determination of picroside II in dog plasma. Plasma samples were deproteinated with acetonitrile and a Hypersil ODS2 column was used with a mobile phase consisted of methanol-water. The determination was validated in the concentration range of 0.10–50 μg mL−1 using 50 μL of plasma. The method was successfully applied to a pharmacokinetic study of picroside II.
相似文献A simple and sensitive method was developed for the determination of three nonsteroidal anti-inflammatory drugs (NSAIDs)—ibuprofen, naproxen and fenbufen in human plasma. The method involved in column liquid chromatographic separation and chemilumenescence (CL) detection based on the CL reaction of NSAIDs, potassium permanganate (KMnO4) and sodium sulfite (Na2SO3) in sulfuric acid (H2SO4) medium. The chromatographic separation was carried out using a reversed-phase C18 column, which allowed the selective determination of the three medicines in the complicated samples. The special features of the CL detector provided lower LOD for determination than that of existing chromatographic alternatives. The results indicated that the linear ranges were 0.01–10.0 μg mL−1 for ibuprofen, 0.001–1.0 μg mL−1 for naproxen, and 0.01–10.0 μg mL−1 for fenbufen. The limits of detection were 0.5 ng mL−1 for ibuprofen, 0.05 ng mL−1 for naproxen and 0.5 ng mL−1 for fenbufen (S/N = 3). All average recoveries were in the range of 90.0–102.3%. Finally, the method had been satisfactorily applied for the determination of ibuprofen, naproxen and fenbufen in human plasma samples.
相似文献A HPLC and a HPTLC-densitometric method were developed for the quantification of prim-O-glucosylcimifugin and 4′-O-β-d-glucosyl-5-O-methylvisamminol the major chromone glucosides in the roots of Saposhnikovia divaricata. The validation of both methods resulted in comparable parameters regarding stability, specificity, linearity, robustness, precision and recovery, whereas complementary advantages were obtained concerning LOD and LOQ. The HPTLC-based densitometry revealed a lower LOD (1.11 versus 4.37 μg mL−1 in HPLC) and LOQ (3.36 versus 13.24 μg mL−1 in HPLC) for prim-O-glucosylcimifugin, whereas the HPLC resulted in a lower LOD (1.00 versus 4.10 μg mL−1 in HPTLC-densitometry) and LOQ (3.04 versus 12.46 μg mL−1 in HPTLC-densitometry) for 4′-O-β-d-glucosyl-5-O-methylvisamminol. Both methods revealed nearly matching contents of the chromones after analysis of different commercially available batches of Saposhnikoviae divaricatae radix with a total content for both chromone glycosides in the range from 0.31 ± 0.011 to 0.56 ± 0.021 % determined by HPLC and between 0.34 ± 0.011 and 0.61 ± 0.009 % determined by HPTLC. The plant material cultivated in Germany showed a very similar content and ratio of both chromone glucosides in comparison to the standard batches originating from China.
相似文献High efficiency and less elution are the basic requirements of high-speed chromatographic separation. In this study, a new gradient reverse phase chromatographic methods were developed using HPLC and UPLC systems for simultaneous determination of enalapril maleate (ENL) and hydrochlorothiazide (HCZ) in pharmaceutical dosage forms. The chromatographic separations of ENL and HCZ were achieved on a Waters μ-Bondapak C 18, (300 × 3.9 mm, 10 μm) and Waters Acquity BEH C18 (100 × 2.1 mm, 1.7 μm) columns for HPLC within 5.30 min and UPLC within a short retention time of 1.95 min, respectively. A linear response was observed over the concentration range 0.270–399 μg mL−1 of ENL, 0.260–399 μg mL−1 of HCZ for HPLC system and 0.270–399 μg mL−1 of ENL and 0.065–249 μg mL−1 of HCZ for UPLC system. Also, limit of detection for ENL was 1.848 ng mL−1 and 31.477 ng mL−1 for HCZ, 2.804 ng mL−1 for ENL and 2.943 ng mL−1 for HCZ using HPLC and UPLC, respectively. The proposed methods were validated according to ICH guideline with respect to precision, accuracy, and linearity. Forced degradation studies were also performed for both compounds in bulk drug samples to demonstrate the specificity and stability indicating power of the HPLC method. Comparison of system performance with conventional HPLC was made with respect to analysis time, efficiency, and resolution.
相似文献A sensitive and simple method based on two-phase liquid-phase microextraction in porous hollow fiber followed by gas chromatography-flame ionization detection was developed for quantification and pharmacokinetic study of valproic acid (VPA, an antiepileptic drug) in rat plasma after oral administration of pure sodium valproate (25 mg kg−1). Some parameters such as type of organic solvent, pH of sample solution, stirring speed, salt addition, extraction time, and volume of sample that affected extraction efficiency of VPA were optimized. Under optimized microextraction conditions, VPA was extracted with 10 μL 1-octanol from 0.5 mL rat plasma previously diluted with 4.5 mL acidified and salinated water (pH 2) using 1-octanoic acid as internal standard. The limit of detection was 17 ng mL−1 with linear response over the concentration range of 50–10,000 ng mL−1 with correlation coefficient higher than 0.998. The developed method was successfully applied to determination of pharmacokinetic parameters such as t max (peak time in concentration–time profile), C max (peak concentration in concentration–time profile), t 1/2 (elimination half-life), AUC0–t (area under the curve for concentration versus time), clearance, and apparent distribution volume in rats following oral administration of VPA.
相似文献A simple, stability-indicating, reversed-phase liquid chromatographic method was developed for the determination of lacidipine in the presence of its degradation products. The analysis was carried out using a 150 mm × 4.6 mm i.d., 5 μm particle size Nucleodur MN-C18 column. Mobile phase containing a mixture of acetonitrile and 0.02 M phosphate buffer (70:30) at pH = 5.0 was pumped at a flow rate of 1 mL min−1 with UV-detection at 254 nm. The method showed good linearity in the range of 0.06–15 μg mL−1 with a limit of detection (S/N = 3) of 0.016 μg mL−1 (3.5 × 10−8 M). The suggested method was successfully applied for the analysis of lacidipine in bulk and in commercial tablets with average recoveries of 100.19 ± 0.81% and 100.05 ± 0.69%, respectively. The results were favorably compared to those obtained by a reference method. The suggested method was utilized to investigate the kinetics of alkaline, acidic, peroxide and photo-induced degradation of the drug. The apparent first-order rate constant, half-life times and activation energies of the degradation process were calculated. The pH profile curve was derived. The proposed method was successfully applied to the content uniformity testing of tablets.
相似文献In this paper, we describe a compact and low-cost light-emitting diode-induced fluorescence (LED-IF) detection coupled to microchip electrophoresis for the determination of sulfonamides in pharmaceutical formulations and rabbit plasma. Three fluorescein isothiocyanate-labeled sulfonamides in rabbit plasma were separated in the running buffer of 40 mM phosphate buffer (pH 7.0) at the separation voltage of 2.0 kV, and detected by LED-IF detector in which the high-power blue LED was driven at the constant current of 150 mA and the emitted fluorescence over 510 nm was collected by a planar photodiode. The linear concentration ranged from 2.0 to 125.0 μg mL−1, both for sulfadiazine and sulfamethazine with the correlation coefficients (r 2) of 0.995 and 0.997, respectively, and from 2.0 to 100.0 μg mL−1 with the correlation coefficients (r 2) of 0.997 for sulfaguanidine. The limits of detection for the three sulfonamides were 0.36–0.50 μg mL−1 (S/N = 3). Intra-day and inter-day precision of migration time and peak area for the determination of sulfonamides were <4.5 %. This method has been successfully applied to the analysis of sulfonamides in pharmaceuticals, and could be used to study the pharmacokinetics of sulfonamides in rabbit.
相似文献