首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Pregnancy alters pharmacokinetic profile of many drugs, because of altering body volume and metabolism rate. Therefore, dosage rates and concentrations of drugs must be controlled during pregnancy. Here, we identified the pharmacokinetic profile of pre-operatively given cefepime in caesarean section and gynecological operations using a simple, rapid, cost-effective and valid liquid chromatographic method. The chromatographic separation was performed using 40 mM, pH 3.2 phosphate buffer containing 6 % methanol as mobile phase at 0.30 mL min?1 flow rate. Gradient elution with methanol was applied to get shorter analysis time without any interference from plasma endogens. During analyses, temperature of column, autosampler and detector were set as 30, 10 and 40 °C, respectively. The detection wavelength was 260 nm and ceftizoxime was used as internal standard. At the optimum conditions, the cefepime analysis from plasma samples was completed in 7 min. Cefepime was extracted from plasma samples using perchloric acid with a very high recovery rate (99.3 %). The method was fully validated according to the Food and Drug Administration guidelines for bioanalytical method validation, and found to be selective, linear, repeatable, reproducible and robust. After validation studies, the method was applied to five caesarean-sectioned and four non-pregnant sectioned women treated with pre-operative, prophylactic single intravenous dose of cefepime (1 g Maxipime®) in order to determine pharmacokinetic profile of cefepime. Peak serum concentrations of cefepime in caesarean-sectioned women at the arterial port after infusion was 70.11 ± 10.74 μg mL?1. The mean elimination half-life, volume of distribution and calculated area under the concentration–time curve (AUC)0–∞ were 1.10 ± 0.23 h, 14.22 ± 2.29 L and 101.55 ± 10.99 μg h mL?1 for caesarean-sectioned women; and 1.14 ± 0.21 h, 14.76 ± 2.92 L and 104.71 ± 36.34 μg h mL?1 for non-pregnant sectioned women, respectively. The area under curve, elimination half-life, maximum plasma concentration and the mean distribution volume of cefepime were not changed in case of pregnancy.  相似文献   

2.
To evaluate the bioequivalence of nateglinide, a rapid and specific liquid chromatographic-electrospray ionization mass spectrometric method was developed and validated to determine nateglinide for human plasma samples. The analyte was detected using electrospray positive ionization mass spectrometry in the selected ion monitoring mode. Tinidazole was used as the internal standard. A good linear relationship obtained in the concentration ranged from 0.05 to 16 μg mL?1 (r 2 = 0.9993). Lower limit of quantification was 0.05 μg mL?1 using 100 μL of plasma sample. Intra- and inter-day relative standard deviations were 2.1–7.5 and 4.7–8.9%, respectively. Among the pharmacokinetic data obtained, T max was 2.09 ± 1.06 h for reference formulation and 2.40 ± 0.97 h for test formulation. C max was 4.17 ± 1.31 μg mL?1 for reference formulation and 4.37 ± 1.53 μg mL?1 for test formulation. The half-life (t ½) was 1.93 ± 0.44 h for reference formulation and 1.92 ± 0.29 h for test formulation. AUC0–10h was 13.67 ± 4.36 μg h mL?1 for reference formulation and 13.21 ± 4.09 μg h mL?1 for test formulation. This method was successfully applied to the pharmacokinetic study in human plasma samples.  相似文献   

3.
Xu  Fan  Xu  Guili  Shang  Beicheng  Yu  Fang 《Chromatographia》2009,69(11):1421-1426

A simple, specific and sensitive liquid chromatographic method has been developed for the assay of ketorolac in human plasma and urine. The clean-up of plasma and urine samples were carried out by protein precipitation procedure and liquid–liquid extraction, respectively. Separation was performed by a Waters sunfire C18 reversed-phase column maintained at 35 °C. The mobile phase was a mixture of 0.02 M phosphate buffer (pH adjusted to 4.5 for plasma samples and to 3.5 for urine samples) and acetonitrile (70:30, v/v) at a flow rate of 1.0 mL min−1. The UV detector was set at 315 nm. Nevirapine was used as an internal standard in the assay of urine sample. The method was validated over the concentration range of 0.05–8 and 0.1–10 μg mL−1 for ketorolac in human plasma and urine, respectively. The limits of detection were 0.02 and 0.04 μg mL−1 for plasma and urine estimation at a signal-to-noise ratio of 3. The limits of quantification were 0.05 and 0.1 μg mL−1 for plasma and urine, respectively. The extraction recoveries were found to be 99.3 ± 4.2 and 80.3 ± 3.7% for plasma and urine, respectively. The intra-day and inter-day standard deviations were less than 0.5. The method indicated good performance in terms of specificity, linearity, detection and quantification limits, precision and accuracy. This assay demonstrated to be applicable for clinical pharmacokinetic studies.

  相似文献   

4.
Zhang  Wei-Dong  Qi  Lian-Wen  Yang  Xiao-Lin  Lu  Yao-Wen  Li  Ping  Yang  Zhong-Lin 《Chromatographia》2008,67(11):1021-1022

A simple, sensitive, and validated liquid chromatographic method has been developed for the determination of tectorigenin in rat plasma and application to a pharmacokinetic study after oral administration of tectorigenin or its prodrug tectoridin. The analysis was performed on a Kromasil C18 analytical column using gradient elution with acetonitrile 0.1% phosphonic acid water at 0.8 mL min−1. The detection wavelength for UV detection was set at 264 nm. The established method was fully validated with parameters as follows: the intra- and inter-day assay precisions (CV) of three analytes were in the range of 4.2–13.3% and accuracies were between 98.0 and 107.5%; the calibration curve was linear with r 2 > 0.99 over a concentration range of 0.02–2 μg mL−1; the lower limit of quantification was 0.02 μg mL−1; tectorigenin showed stable in rat plasma after 12 h incubation at room temperature, 15 days storage at −80 °C and three freeze/thaw cycles, as well as in reconstitute buffer for 24 h at 25 °C; and the mean recoveries of tectorigenin were 92.3 ± 3.2, 95.5 ± 2.9 and 94.5 ± 3.0% with quality control levels of 0.02, 0.2 and 2 μg mL−1, respectively. In conclusion, this method is simple, economic, and sensitive enough for in vivo pharmacokinetic studies of tectorigenin.

  相似文献   

5.
Wang  Huan  Chen  Yan  Zhou  Jia  Ma  Chen  Chen  Yuancheng  Liu  Xiaoquan 《Chromatographia》2008,67(11):875-881

A stereoselective liquid chromatographic method to determine the enantiomers of ornidazole in human plasma and urine has been developed and validated. After addition of the internal standard (naproxen), samples were acidified and extracted with diethyl ether. The separation was performed on a Chiralcel OB-H column, using hexane-ethanol- glacial acetic acid (94:6:0.08, v/v) as the mobile phase. The method was validated for specificity, linearity, sensitivity, precision, accuracy and stability. For each enantiomer of ornidazole, linear calibration curves were obtained over the concentration range of 0.16–20 μg mL−1 in plasma and 0.32–20 μg mL−1 in urine. For both enantiomers of ornidazole in plasma and urine, the coefficient of variation for precision were consistently less than 12% and accuracy were within ±14% in terms of relative error. Application of the method to a preliminary pharmacokinetic study showed that this validated method was qualified for the direct determination of ornidazole enantiomers in human plasma and urine.

  相似文献   

6.
A simple, rapid and sensitive liquid chromatography–mass spectrometry (LC–MS) method was developed for the quantification of salidroside in rat plasma and the study of its pharmacokinetics after oral administration of 15 g kg?1 Rhodiola crenulata extract to Wistar rats. A 200 μL plasma sample was extracted by acetonitrile and performed on Kromasil C18 column (150 mm × 4.6 mm, 5 μm) with the mobile phase of acetonitrile–water (11:89) within a run time of 8 min. The analyte was monitored with electrospray ionization (ESI) by selected ion monitoring (SIM) mode. The target ions were m/z 299.20 for salidroside and m/z 150.00 for internal standard (IS) paracetamol. A good linear relationship was obtained over the range of 100–20,000 ng mL?1 and the lower limit of quantification was 100 ng mL?1. The validated method was successfully applied for the pharmacokinetic study of salidroside in rat. After oral administration of Rhodiola crenulata extract, the main pharmacokinetic parameters T max, T 1/2, C max, AUC 0?t and AUC 0?∞ were 0.56 ± 0.21 h, 7.91 ± 4.42 h, 3,386 ± 2,138 ng mL?1, 16,146 ± 6,558 ng h mL?1 and 18,599 ± 6,529 ng h mL?1, respectively.  相似文献   

7.
A simple, sensitive, and validated liquid chromatographic method has been developed for the determination of tectorigenin in rat plasma and application to a pharmacokinetic study after oral administration of tectorigenin or its prodrug tectoridin. The analysis was performed on a Kromasil C18 analytical column using gradient elution with acetonitrile 0.1% phosphonic acid water at 0.8 mL min?1. The detection wavelength for UV detection was set at 264 nm. The established method was fully validated with parameters as follows: the intra- and inter-day assay precisions (CV) of three analytes were in the range of 4.2–13.3% and accuracies were between 98.0 and 107.5%; the calibration curve was linear with r 2 > 0.99 over a concentration range of 0.02–2 μg mL?1; the lower limit of quantification was 0.02 μg mL?1; tectorigenin showed stable in rat plasma after 12 h incubation at room temperature, 15 days storage at ?80 °C and three freeze/thaw cycles, as well as in reconstitute buffer for 24 h at 25 °C; and the mean recoveries of tectorigenin were 92.3 ± 3.2, 95.5 ± 2.9 and 94.5 ± 3.0% with quality control levels of 0.02, 0.2 and 2 μg mL?1, respectively. In conclusion, this method is simple, economic, and sensitive enough for in vivo pharmacokinetic studies of tectorigenin.  相似文献   

8.

Taurine is an amino acid which is not incorporated into proteins but found in the cytosol of many mammalian cells, in high concentrations (2–30 mM). Increase in plasma taurine concentration has already been reported after surgical trauma, X-radiation, muscle necrosis, carbon tetrachloride-induced liver damage, and paracetamol overdose. Plasma taurine concentration was measured using LC with fluorescence detection following derivatization by o-phtalaldehyde plus 3-mercapto-propionic acid and α-aminobutyric acid as internal standard. Under these conditions the retention time of taurine was 10 min. This method was sensitive enough, to quantify 150 pg mL−1 and detect 50 pg mL−1 of taurine ranging normally between 65 and 179 mmol L−1 (8–22 μg mL−1). The validated method allowed simple determination of human plasma taurine in pharmacokinetic and biomarker studies.

  相似文献   

9.
He  Hui  Chen  Xi J.  Wang  Guang Ji 《Chromatographia》2008,67(11):1013-1016

A high-performance liquid chromatography-electrospray ionization-mass spectromentry (LC–ESI–MS) method has been developed for the determination of picroside II in dog plasma. Plasma samples were deproteinated with acetonitrile and a Hypersil ODS2 column was used with a mobile phase consisted of methanol-water. The determination was validated in the concentration range of 0.10–50 μg mL−1 using 50 μL of plasma. The method was successfully applied to a pharmacokinetic study of picroside II.

  相似文献   

10.
A simple and specific high performance liquid chromatographic (HPLC) method with UV detection using picroside II as the internal standard was developed and validated to determine the concentration of paeoniflorin in rat plasma and study its pharmacokinetics after an single intravenous administration of 40 mg kg?1 paeoniflorin to Wistar rats. The analytes of interest were extracted from rat plasma samples by ethyl acetate after acidification with 0.05 mol L?1 NaH2PO4 solution (pH 5.0). Chromatographic separation was achieved on an Agilent XDB C18 column (250 × 4.6 mm I.D., 5 μm) with a Shim-pack GVP-ODS C18 guard column (10 × 4.6 mm I.D., 5 μm) using a mobile phase consisting of acetonitrile–water–acetic acid (18:82:0.4, v/v/v) at a flow rate of 1.0 mL min?1. The UV detection was performed at a wavelength of 230 nm. The linear calibration curves were obtained in the concentration range of 0.05–200.0 μg mL?1 in rat plasma with the lower limit of quantification (LLOQ) of 0.05 μg mL?1. The intra- and inter-day precisions in terms of % relative standard deviation (RSD) were lower than 5.7 and 8.2% in rat plasma, respectively. The accuracy in terms of % relative error (RE) ranged from ?1.9 to 2.6% in rat plasma. The extraction recoveries of paeoniflorin and picroside II were calculated to be 69.7 and 56.9%, respectively. This validated method was successfully applied to the pharmacokinetic study of a new paeoniflorin frozen dry power formulation. After single intravenous administration, the main pharmacokinetic parameters t 1/2, AUC0-∞, CLTOT, V Z, MRT0-∞ and V ss were 0.739 ± 0.232 h, 43.75 ± 6.90 μg h mL?1, 15.50 ± 2.46 L kg?1 h?1, 1.003 ± 0.401 L kg?1, 0.480 ± 0.055 h and 0.444 ± 0.060 L kg?1, respectively.  相似文献   

11.
A simple, rapid, sensitive and reliable liquid chromatographic method for the quantification of BP-1107 in rat plasma has been established. Plasma samples were prepared by extraction with tert-butyl methyl ether, and troglitazone was used as an internal standard. The analytical separation was performed on a C18 column using acetonitrile–0.3% phosphoric acid in water (pH 4.00 adjusted with triethylamine) (75:25, v/v) as a mobile phase. A detailed validation of the method was performed as per USFDA guidelines. For BP-1107 at the concentrations of 2.42, 16.11 and 32.22 μg mL?1 in rat plasma, the extraction recoveries were 114.14 ± 9.75, 95.37 ± 12.06 and 90.00 ± 6.46%, respectively. The mean recovery for internal standard was 91.96 ± 2.51%. The lower limit of quantitation of BP-1107 was 16 ng. The linear quantification range of the method was 0.81–53.70 μg mL?1 in rat plasma with a correlation coefficient greater than 0.999. The intra-day and inter-day accuracy for BP-1107 at 2.42, 16.11 and 32.22 μg mL?1 levels in rat plasma fell between 97.10–110.02 and 97.52–108.04%. The intra-day and inter-day precision were in the ranges of 1.91–5.63 and 4.43–6.28%, respectively. The method was successfully applied to a pharmacokinetic study of BP-1107 in rats after an intravenous administration.  相似文献   

12.
Xiong  Xunyu  Zhang  Qunzheng  Xiong  Fengmei  Tang  Yuhai 《Chromatographia》2008,67(11):929-934

A simple and sensitive method was developed for the determination of three nonsteroidal anti-inflammatory drugs (NSAIDs)—ibuprofen, naproxen and fenbufen in human plasma. The method involved in column liquid chromatographic separation and chemilumenescence (CL) detection based on the CL reaction of NSAIDs, potassium permanganate (KMnO4) and sodium sulfite (Na2SO3) in sulfuric acid (H2SO4) medium. The chromatographic separation was carried out using a reversed-phase C18 column, which allowed the selective determination of the three medicines in the complicated samples. The special features of the CL detector provided lower LOD for determination than that of existing chromatographic alternatives. The results indicated that the linear ranges were 0.01–10.0 μg mL−1 for ibuprofen, 0.001–1.0 μg mL−1 for naproxen, and 0.01–10.0 μg mL−1 for fenbufen. The limits of detection were 0.5 ng mL−1 for ibuprofen, 0.05 ng mL−1 for naproxen and 0.5 ng mL−1 for fenbufen (S/N = 3). All average recoveries were in the range of 90.0–102.3%. Finally, the method had been satisfactorily applied for the determination of ibuprofen, naproxen and fenbufen in human plasma samples.

  相似文献   

13.
Fan Xu  Guili Xu  Beicheng Shang  Fang Yu 《Chromatographia》2009,69(11-12):1421-1426
A simple, specific and sensitive liquid chromatographic method has been developed for the assay of ketorolac in human plasma and urine. The clean-up of plasma and urine samples were carried out by protein precipitation procedure and liquid–liquid extraction, respectively. Separation was performed by a Waters sunfire C18 reversed-phase column maintained at 35 °C. The mobile phase was a mixture of 0.02 M phosphate buffer (pH adjusted to 4.5 for plasma samples and to 3.5 for urine samples) and acetonitrile (70:30, v/v) at a flow rate of 1.0 mL min?1. The UV detector was set at 315 nm. Nevirapine was used as an internal standard in the assay of urine sample. The method was validated over the concentration range of 0.05–8 and 0.1–10 μg mL?1 for ketorolac in human plasma and urine, respectively. The limits of detection were 0.02 and 0.04 μg mL?1 for plasma and urine estimation at a signal-to-noise ratio of 3. The limits of quantification were 0.05 and 0.1 μg mL?1 for plasma and urine, respectively. The extraction recoveries were found to be 99.3 ± 4.2 and 80.3 ± 3.7% for plasma and urine, respectively. The intra-day and inter-day standard deviations were less than 0.5. The method indicated good performance in terms of specificity, linearity, detection and quantification limits, precision and accuracy. This assay demonstrated to be applicable for clinical pharmacokinetic studies.  相似文献   

14.
Scher&#;bl  Rosmarie  Manns  Detlef  Heilmann  J&#;rg  Franz  Gerhard 《Chromatographia》2013,76(21):1537-1543

A HPLC and a HPTLC-densitometric method were developed for the quantification of prim-O-glucosylcimifugin and 4′-O-β-d-glucosyl-5-O-methylvisamminol the major chromone glucosides in the roots of Saposhnikovia divaricata. The validation of both methods resulted in comparable parameters regarding stability, specificity, linearity, robustness, precision and recovery, whereas complementary advantages were obtained concerning LOD and LOQ. The HPTLC-based densitometry revealed a lower LOD (1.11 versus 4.37 μg mL−1 in HPLC) and LOQ (3.36 versus 13.24 μg mL−1 in HPLC) for prim-O-glucosylcimifugin, whereas the HPLC resulted in a lower LOD (1.00 versus 4.10 μg mL−1 in HPTLC-densitometry) and LOQ (3.04 versus 12.46 μg mL−1 in HPTLC-densitometry) for 4′-O-β-d-glucosyl-5-O-methylvisamminol. Both methods revealed nearly matching contents of the chromones after analysis of different commercially available batches of Saposhnikoviae divaricatae radix with a total content for both chromone glycosides in the range from 0.31 ± 0.011 to 0.56 ± 0.021 % determined by HPLC and between 0.34 ± 0.011 and 0.61 ± 0.009 % determined by HPTLC. The plant material cultivated in Germany showed a very similar content and ratio of both chromone glucosides in comparison to the standard batches originating from China.

  相似文献   

15.
Uslu  Bengi  &#;zden  Tugba 《Chromatographia》2013,76(21):1487-1494

High efficiency and less elution are the basic requirements of high-speed chromatographic separation. In this study, a new gradient reverse phase chromatographic methods were developed using HPLC and UPLC systems for simultaneous determination of enalapril maleate (ENL) and hydrochlorothiazide (HCZ) in pharmaceutical dosage forms. The chromatographic separations of ENL and HCZ were achieved on a Waters μ-Bondapak C 18, (300 × 3.9 mm, 10 μm) and Waters Acquity BEH C18 (100 × 2.1 mm, 1.7 μm) columns for HPLC within 5.30 min and UPLC within a short retention time of 1.95 min, respectively. A linear response was observed over the concentration range 0.270–399 μg mL−1 of ENL, 0.260–399 μg mL−1 of HCZ for HPLC system and 0.270–399 μg mL−1 of ENL and 0.065–249 μg mL−1 of HCZ for UPLC system. Also, limit of detection for ENL was 1.848 ng mL−1 and 31.477 ng mL−1 for HCZ, 2.804 ng mL−1 for ENL and 2.943 ng mL−1 for HCZ using HPLC and UPLC, respectively. The proposed methods were validated according to ICH guideline with respect to precision, accuracy, and linearity. Forced degradation studies were also performed for both compounds in bulk drug samples to demonstrate the specificity and stability indicating power of the HPLC method. Comparison of system performance with conventional HPLC was made with respect to analysis time, efficiency, and resolution.

  相似文献   

16.
A novel and simple liquid chromatographic (LC) method was developed for quantification of a new anticancer compound, chloride 3-methyl-9-(2-oxa-2λ5-2H-1,3,2-oxazaphosphorine-2-cyclohexyl)-3,6,9-triazaspiro [5.5] undecane (SLXM-2) in rat plasma. The present method used protein precipitation for extraction of SLXM-2 from rat plasma. Separation was carried out on a reversed-phase C18 column (150 mm × 4.6 mm i.d., 5 μm). The mobile phases consisted of acetonitrile and 2 mM sodium dodecyl sulfate (SDS) (24:76, v/v). The flow rate was 1.0 mL min?1. A diode-array detector (DAD) was used and the column effluent was monitored at 192 nm. Regression equations revealed good linear relationship between the peak area and the concentration. The correlation coefficient was 0.9996. The relative standard deviations (RSD) of the precision and accuracy were <9.0% (intra-day) and <6.1% (inter-day), respectively. The recovery and stability were found satisfactory during the study. The method was successfully applied for the pharmacokinetic study of SLXM-2 in rats. After a single dose (400 mg kg?1) of SLXM-2 was given to rats by intravenous injection, the half-life of SLXM-2 was 0.304 h, the area under the plasma concentration–time curve was 673.1 μg h mL?1 and the maximal plasma concentration was 1534.9 ± 185.8 μg mL?1.  相似文献   

17.
Jahangiri  Shima  Hatami  Mehdi  Farhadi  Khalil  Bahram  Morteza 《Chromatographia》2013,76(11):663-669

A sensitive and simple method based on two-phase liquid-phase microextraction in porous hollow fiber followed by gas chromatography-flame ionization detection was developed for quantification and pharmacokinetic study of valproic acid (VPA, an antiepileptic drug) in rat plasma after oral administration of pure sodium valproate (25 mg kg−1). Some parameters such as type of organic solvent, pH of sample solution, stirring speed, salt addition, extraction time, and volume of sample that affected extraction efficiency of VPA were optimized. Under optimized microextraction conditions, VPA was extracted with 10 μL 1-octanol from 0.5 mL rat plasma previously diluted with 4.5 mL acidified and salinated water (pH 2) using 1-octanoic acid as internal standard. The limit of detection was 17 ng mL−1 with linear response over the concentration range of 50–10,000 ng mL−1 with correlation coefficient higher than 0.998. The developed method was successfully applied to determination of pharmacokinetic parameters such as t max (peak time in concentration–time profile), C max (peak concentration in concentration–time profile), t 1/2 (elimination half-life), AUC0–t (area under the curve for concentration versus time), clearance, and apparent distribution volume in rats following oral administration of VPA.

  相似文献   

18.
A liquid chromatographic method for analysis of pazufloxacin mesilate in human plasma and urine has been developed and validated for selectivity, sensitivity, accuracy, precision, and stability in pharmacokinetic analysis. The sensitivity of the method was 0.02 μg mL?1 in plasma and 0.5 μg mL?1 in urine, with overall intra-day and inter-day precision (RSD < 10%) and accuracy (90–120%) acceptable for clinical pharmacokinetic analysis. Recovery from plasma and urine was 80–110% for both pazufloxacin mesilate and enoxacin, the internal standard. Pazufloxacin was stable in both plasma and urine, with no significant degradation under four different conditions. The method was successfully used in a preliminary study of the bioavailability of pazufloxacin mesilate in healthy human volunteers after intravenous administration of 300 and 500 mg.  相似文献   

19.
Belal  Fathalla  Elbrashy  Amina  Eid  Manal  Nasr  Jenny Jeehan 《Chromatographia》2009,69(11):1201-1209

A simple, stability-indicating, reversed-phase liquid chromatographic method was developed for the determination of lacidipine in the presence of its degradation products. The analysis was carried out using a 150 mm × 4.6 mm i.d., 5 μm particle size Nucleodur MN-C18 column. Mobile phase containing a mixture of acetonitrile and 0.02 M phosphate buffer (70:30) at pH = 5.0 was pumped at a flow rate of 1 mL min−1 with UV-detection at 254 nm. The method showed good linearity in the range of 0.06–15 μg mL−1 with a limit of detection (S/N = 3) of 0.016 μg mL−1 (3.5 × 10−8 M). The suggested method was successfully applied for the analysis of lacidipine in bulk and in commercial tablets with average recoveries of 100.19 ± 0.81% and 100.05 ± 0.69%, respectively. The results were favorably compared to those obtained by a reference method. The suggested method was utilized to investigate the kinetics of alkaline, acidic, peroxide and photo-induced degradation of the drug. The apparent first-order rate constant, half-life times and activation energies of the degradation process were calculated. The pH profile curve was derived. The proposed method was successfully applied to the content uniformity testing of tablets.

  相似文献   

20.
Zhang  Beibei  Chen  Zuanguang  Yu  Yanyan  Yang  Jianping  Pan  Jianbin 《Chromatographia》2013,76(13):821-829

In this paper, we describe a compact and low-cost light-emitting diode-induced fluorescence (LED-IF) detection coupled to microchip electrophoresis for the determination of sulfonamides in pharmaceutical formulations and rabbit plasma. Three fluorescein isothiocyanate-labeled sulfonamides in rabbit plasma were separated in the running buffer of 40 mM phosphate buffer (pH 7.0) at the separation voltage of 2.0 kV, and detected by LED-IF detector in which the high-power blue LED was driven at the constant current of 150 mA and the emitted fluorescence over 510 nm was collected by a planar photodiode. The linear concentration ranged from 2.0 to 125.0 μg mL−1, both for sulfadiazine and sulfamethazine with the correlation coefficients (r 2) of 0.995 and 0.997, respectively, and from 2.0 to 100.0 μg mL−1 with the correlation coefficients (r 2) of 0.997 for sulfaguanidine. The limits of detection for the three sulfonamides were 0.36–0.50 μg mL−1 (S/N = 3). Intra-day and inter-day precision of migration time and peak area for the determination of sulfonamides were <4.5 %. This method has been successfully applied to the analysis of sulfonamides in pharmaceuticals, and could be used to study the pharmacokinetics of sulfonamides in rabbit.

  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号