首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 46 毫秒
1.
Scher&#;bl  Rosmarie  Manns  Detlef  Heilmann  J&#;rg  Franz  Gerhard 《Chromatographia》2013,76(21):1537-1543

A HPLC and a HPTLC-densitometric method were developed for the quantification of prim-O-glucosylcimifugin and 4′-O-β-d-glucosyl-5-O-methylvisamminol the major chromone glucosides in the roots of Saposhnikovia divaricata. The validation of both methods resulted in comparable parameters regarding stability, specificity, linearity, robustness, precision and recovery, whereas complementary advantages were obtained concerning LOD and LOQ. The HPTLC-based densitometry revealed a lower LOD (1.11 versus 4.37 μg mL−1 in HPLC) and LOQ (3.36 versus 13.24 μg mL−1 in HPLC) for prim-O-glucosylcimifugin, whereas the HPLC resulted in a lower LOD (1.00 versus 4.10 μg mL−1 in HPTLC-densitometry) and LOQ (3.04 versus 12.46 μg mL−1 in HPTLC-densitometry) for 4′-O-β-d-glucosyl-5-O-methylvisamminol. Both methods revealed nearly matching contents of the chromones after analysis of different commercially available batches of Saposhnikoviae divaricatae radix with a total content for both chromone glycosides in the range from 0.31 ± 0.011 to 0.56 ± 0.021 % determined by HPLC and between 0.34 ± 0.011 and 0.61 ± 0.009 % determined by HPTLC. The plant material cultivated in Germany showed a very similar content and ratio of both chromone glucosides in comparison to the standard batches originating from China.

  相似文献   

2.

A reversed phase LC method was developed and validated to analyze the in vitro release of AZT from microemulsions. A mobile phase of acetonitrile:water (15:85) was used. The method validation showed good selectivity and linearity (r = 0.9993) for sample concentrations ranging from 0.6 to 100.0 μg mL−1. The RSD values (0.7–4.3%) and percentage recovery (88.1–109.8%) were within acceptable limits. The limit of detection (LOD) and limit of quantitation (LOQ) were found to be 0.012 and 0.041 μg mL−1. Quantitative analysis of the values obtained in the drug release assay indicates that the microemulsions used promote sustained release of AZT, which follows a Fickian diffusion mechanism.

  相似文献   

3.
Aksoy  B.  K&#;&#;&#;kg&#;zel  &#;.  Rollas  S. 《Chromatographia》2007,66(1):57-63

The objective of the current study was the development and subsequent validation of a simple, sensitive, precise and stability-indicating reversed-phase HPLC method for the determination of ciprofloxacin HCl in pharmaceutical dosage forms in the presence of its potential impurities. The chromatographic separation of ciprofloxacin HCl and its related compounds was achieved on an Inertsil ODS3 column using UV detection. The optimized mobile phase consisted of phosphoric acid solution: acetonitril. The proposed method provided linear responses within the concentration range 250–750 μg mL−1 for ciprofloxacin HCl and 0.5–1.5 μg mL−1 for its related compounds. LOD and LOQ values for the active substance were 5.159 and 15.632 μg mL−1, respectively. Correlation coefficients (r) of the regression equations for the impurities were greater than 0.99 in all cases. The precision of the method was demonstrated using intra- and inter-day assay RSD% values which were less than 1% in all instances. No interference from any components of pharmaceutical dosage forms or degradation products was observed.

  相似文献   

4.

A simple and rapid development of a stability-indicating LC method for determination of chloroquine diphosphate in the presence of its hydrolysis, oxidative and photolysis degradation products is described. Stress testing showed that chloroquine diphosphate was degraded under basic conditions and by photolytic treatment but was stable under the other stress conditions investigated. Separation of the drug from its degradation products was achieved with a Nova Pack C18 column, 0.01 M PIC B7 and acetonitrile (40:60 v/v) pH 3.6, as mobile phase. Response was linear over the range 0.08–5.70 μg mL−1 (= 0.996), with limits of detection and quantification (LOD and LOQ) of 0.17 and 0.35 μg mL−1, respectively.

  相似文献   

5.
Liu  Yongmei  Liao  Mengya  Zhang  Cuiwei  Bai  Yuli  Song  Honglian  Zhang  Yiwen  Wang  Xin 《Chromatographia》2015,78(23):1485-1489

A precise and sensitive LC method for the determination of repertaxin enantiomeric purity has been developed and validated. Baseline separation with a resolution higher than 2.0 was accomplished within 20 min using a Chiralpak AD-H column (250 × 4.6 mm; particle size 5 μm) and n-hexane:2-propanol (90:10 v/v) as mobile phase at a flow rate of 1 mL min−1. Eluted analytes were monitored by UV detection at 260 nm. The effects of mobile phase composition, temperature and flow rate on enantiomeric selectivity and on resolution of enantiomers were investigated. Calibration curves were plotted within the concentration range between 0.002 and 1.0 mg mL−1 (n = 3), and relative standard deviation (RSD) of the inter-batch assay and intra-batch assay was less than 1.27 and 1.16 %. LOD and LOQ for repertaxin were 0.65 and 2.19 μg mL−1; those for its enantiomer were 0.70 and 2.34 μg mL−1, respectively. The method was evaluated and validated by analysis of bulk samples of repertaxin of different enantiomeric purity. It was demonstrated that the method was accurate, robust, and sensitive, and enabled practical analysis of real samples.

  相似文献   

6.

This paper describes the validation of an isocratic LC method for the assay of linezolid in tablets. Validation parameters such as linearity, precision, accuracy, specificity, limit of detection, limit of quantitation and robustness were determined. LC was carried out by reversed phase technique on an RP-18 column with a mobile phase composed of 1% acetic acid:methanol:acetonitrile (50:25:25, v/v/v). Linezolid and your combination drug product were exposed to acid, base, oxidation, dry heat and photolytic stress conditions. A linear response (r > 0.9999) was observed in the range of 8.0–20.0 μg mL−1. The retention time of linezolid was 4.6 min. The method showed good recoveries and intra- and inter-day relative standard deviations were less than 1.0%. The LOD and LOQ were 0.21 and 0.63 μg mL−1, respectively. The developed LC method for determination of related substances and assay determination of linezolid can be used to evaluate the quality of regular production samples. It can also be used to test the stability samples of linezolid.

  相似文献   

7.
Zhang  Beibei  Chen  Zuanguang  Yu  Yanyan  Yang  Jianping  Pan  Jianbin 《Chromatographia》2013,76(13):821-829

In this paper, we describe a compact and low-cost light-emitting diode-induced fluorescence (LED-IF) detection coupled to microchip electrophoresis for the determination of sulfonamides in pharmaceutical formulations and rabbit plasma. Three fluorescein isothiocyanate-labeled sulfonamides in rabbit plasma were separated in the running buffer of 40 mM phosphate buffer (pH 7.0) at the separation voltage of 2.0 kV, and detected by LED-IF detector in which the high-power blue LED was driven at the constant current of 150 mA and the emitted fluorescence over 510 nm was collected by a planar photodiode. The linear concentration ranged from 2.0 to 125.0 μg mL−1, both for sulfadiazine and sulfamethazine with the correlation coefficients (r 2) of 0.995 and 0.997, respectively, and from 2.0 to 100.0 μg mL−1 with the correlation coefficients (r 2) of 0.997 for sulfaguanidine. The limits of detection for the three sulfonamides were 0.36–0.50 μg mL−1 (S/N = 3). Intra-day and inter-day precision of migration time and peak area for the determination of sulfonamides were <4.5 %. This method has been successfully applied to the analysis of sulfonamides in pharmaceuticals, and could be used to study the pharmacokinetics of sulfonamides in rabbit.

  相似文献   

8.

Fleroxacin is a third generation fluoroquinolone with broad spectrum antibacterial activity. In this work an LC-DAD method for the analysis of fleroxacin was developed and validated using UV detection at 286 nm. The method was validated for linearity, precision, robustness, LOD, LOQ, specificity and accuracy at concentrations of 0.2–20.0 μg mL−1 and r 2 = 1. The LOD and LOQ were 0.059 and 0.197 μg, respectively, the recoveries were 99.92–102.0% and the CV was less than 2.0%. The LC-DAD validated method provided analytical sensitivity, specificity and reproducibility suitable for quality control analysis.

  相似文献   

9.
Fang  Lina  Wang  Qiudi  Bi  Kaishun  Zhao  Xu 《Chromatographia》2016,79(23):1659-1663

A sensitive and simple HPLC method for simultaneous determination of PAC-1 (first procaspase-activating compound), phenol red, and permeability markers (carbamazepine and furosemide) in perfusion samples was developed and validated to assess intestinal absorption of PAC-1 using single-pass intestinal perfusion technique (SPIP) in rats. The chromatographic separation was carried out on a Kromasil C18 column (150 mm × 4.6 mm, 5 μm) with acetonitrile–methanol–30 mmol L−1 phosphate buffer (pH 3.0, 25:10:65, v/v/v) as mobile phase at a flow rate of 1.0 mL min−1, and the wavelength of the UV detector was set at 281 nm. The calibration curves were linear in the ranges of 2.40–48.0 μg mL−1 for PAC-1; 3.60–72.0 μg mL−1 for carbamazepine; 3.20–64.0 μg mL−1 for furosemide, and 4.80–96.0 μg mL−1 for phenol red (r > 0.999). Both the intra- and inter-day precisions (RSD%) of all analytes were less than 6.8 % at three concentration levels, while accuracy ranged from 95.4 to 104.5 %. Data obtained in all method validation studies indicated that the method was suitable for the intended purpose. The effective permeability values (P eff) considering water flux with the help of non-permeable marker phenol red was calculated to be 0.42 × 10−4, 0.62 × 10−4, 0.32 × 10−4 cm s−1 for PAC-1; 0.72 × 10−4, 0.77 × 10−4, 0.52 × 10−4 cm s−1 for carbamazepine; 0.20 × 10−4, 0.16 × 10−4, 0.12 × 10−4 cm s−1 for furosemide in duodenum, jejunum and ileum, respectively. The P eff value can be increased by co-perfusion with verapamil, indicating that absorption of PAC-1 is efficiently transported by P-glycoprotein (P-gp) in the gut wall.

  相似文献   

10.

Two separation techniques were developed for the determination of S-(−)darifenacin (DAR) in the presence of its R-(+) isomer: The first method is high performance liquid chromatography (HPLC) and the second is capillary electrophoresis (CE). Chiral separation for chromatographic HPLC method development was carried out for S-DAR on Daicel CROWNPAK CR (+) (5 μm, 4.0 × 150 mm) column which contains (3,3-diphenyl-1,1-binaphthyl)-crown-6 coated onto a 5.5 μm silica support. The mobile phase system was aqueous acidic 70 % HClO4 (pH 2.5): methanol in the proportion of 90:10 v/v. This current mobile phase was delivered at flow rate 0.8 mL min−1 using UV detector adjusted at 286 nm. In CE method, the enantiomers were separated using 50 μm inner diameter fused-silica capillary cut to total lengths of 31.2 cm using 50 mM phosphate buffer as background electrolyte adjusted to pH 2.5 by triethanolamine. A wide range of cyclodextrins (CDs) were used such as highly sulfated α, γ CDs, hydroxyl propyl-β-CD and sulfobutyl ether-β-CD as chiral selectors. The effects of chiral additives regarding its concentration and content of organic modifier on the enantioseparation were investigated. Linear concentration ranges were from 2.5 to 50 and 40 to 300 μg mL−1 with detection limits 0.67 and 12.28 μg mL−1 for chromatographic HPLC and electrophoretic CE methods, respectively. The two methods were validated according to ICH guidelines with respect to linearity, accuracy, precision, LOQ, LOD and robustness. The suggested methods are suitable for separation and quantitation of S-DAR in tablets.

  相似文献   

11.
Xiong  Xunyu  Zhang  Qunzheng  Xiong  Fengmei  Tang  Yuhai 《Chromatographia》2008,67(11):929-934

A simple and sensitive method was developed for the determination of three nonsteroidal anti-inflammatory drugs (NSAIDs)—ibuprofen, naproxen and fenbufen in human plasma. The method involved in column liquid chromatographic separation and chemilumenescence (CL) detection based on the CL reaction of NSAIDs, potassium permanganate (KMnO4) and sodium sulfite (Na2SO3) in sulfuric acid (H2SO4) medium. The chromatographic separation was carried out using a reversed-phase C18 column, which allowed the selective determination of the three medicines in the complicated samples. The special features of the CL detector provided lower LOD for determination than that of existing chromatographic alternatives. The results indicated that the linear ranges were 0.01–10.0 μg mL−1 for ibuprofen, 0.001–1.0 μg mL−1 for naproxen, and 0.01–10.0 μg mL−1 for fenbufen. The limits of detection were 0.5 ng mL−1 for ibuprofen, 0.05 ng mL−1 for naproxen and 0.5 ng mL−1 for fenbufen (S/N = 3). All average recoveries were in the range of 90.0–102.3%. Finally, the method had been satisfactorily applied for the determination of ibuprofen, naproxen and fenbufen in human plasma samples.

  相似文献   

12.

This paper describes development and validation of a high-performance liquid chromatographic method for simultaneous analysis of tramadol hydrochloride (TR) and aceclofenac (AC) in a tablet formulation. When the combination formulation was subjected to ICH-recommended stress conditions, adequate separation of TR, AC, and the degradation products formed was achieved on a C18 column with 65:35 (v/v) 0.01 M ammonium acetate buffer, pH 6.5—acetonitrile as mobile phase at a flow rate of 1 mL min−1. UV detection was performed at 270 nm. The method was validated for specificity, linearity, LOD and LOQ, precision, accuracy, and robustness. The method was specific against placebo interference and also during forced degradation. The linearity of the method was investigated in the concentration ranges 15–60 μg mL−1 (r = 0.9999) for TR and 40–160 μg mL−1 (r = 0.9999) for AC. Accuracy was between 98.87 and 99.32% for TR and between 98.81 and 99.49% for AC. Because degradation products were well separated from the parent compounds, the method was stability-indicating.

  相似文献   

13.
Xu  Fan  Xu  Guili  Shang  Beicheng  Yu  Fang 《Chromatographia》2009,69(11):1421-1426

A simple, specific and sensitive liquid chromatographic method has been developed for the assay of ketorolac in human plasma and urine. The clean-up of plasma and urine samples were carried out by protein precipitation procedure and liquid–liquid extraction, respectively. Separation was performed by a Waters sunfire C18 reversed-phase column maintained at 35 °C. The mobile phase was a mixture of 0.02 M phosphate buffer (pH adjusted to 4.5 for plasma samples and to 3.5 for urine samples) and acetonitrile (70:30, v/v) at a flow rate of 1.0 mL min−1. The UV detector was set at 315 nm. Nevirapine was used as an internal standard in the assay of urine sample. The method was validated over the concentration range of 0.05–8 and 0.1–10 μg mL−1 for ketorolac in human plasma and urine, respectively. The limits of detection were 0.02 and 0.04 μg mL−1 for plasma and urine estimation at a signal-to-noise ratio of 3. The limits of quantification were 0.05 and 0.1 μg mL−1 for plasma and urine, respectively. The extraction recoveries were found to be 99.3 ± 4.2 and 80.3 ± 3.7% for plasma and urine, respectively. The intra-day and inter-day standard deviations were less than 0.5. The method indicated good performance in terms of specificity, linearity, detection and quantification limits, precision and accuracy. This assay demonstrated to be applicable for clinical pharmacokinetic studies.

  相似文献   

14.
15.
A simple, fast, inexpensive capillary zone electrophoresis method for the separation and determination of tiapride hydrochloride and its two related impurities in pharmaceutical formulations has been developed and validated. The successful separation of these compounds was achieved in less than 3 min using a fused silica capillary and photodiode array detector at 218 nm. The best conditions were obtained using a 10 mM sodium tetraborate (pH 8.0) as the running buffer. The linear responses covered the ranges from 1.0 to 100 μg mL?1 (R = 0.9989) for tiapride hydrochloride. The detection (LOD) and quantitation limits (LOQ) for tiapride hydrochloride were 2.7 and 9.0 μg mL?1, respectively. The intra- and inter-day relative standard deviations for migration times and peak areas were less than 0.47 and 5.7%, respectively. The method was validated for the determination of tiapride hydrochloride in commercial tablets.  相似文献   

16.
Uslu  Bengi  &#;zden  Tugba 《Chromatographia》2013,76(21):1487-1494

High efficiency and less elution are the basic requirements of high-speed chromatographic separation. In this study, a new gradient reverse phase chromatographic methods were developed using HPLC and UPLC systems for simultaneous determination of enalapril maleate (ENL) and hydrochlorothiazide (HCZ) in pharmaceutical dosage forms. The chromatographic separations of ENL and HCZ were achieved on a Waters μ-Bondapak C 18, (300 × 3.9 mm, 10 μm) and Waters Acquity BEH C18 (100 × 2.1 mm, 1.7 μm) columns for HPLC within 5.30 min and UPLC within a short retention time of 1.95 min, respectively. A linear response was observed over the concentration range 0.270–399 μg mL−1 of ENL, 0.260–399 μg mL−1 of HCZ for HPLC system and 0.270–399 μg mL−1 of ENL and 0.065–249 μg mL−1 of HCZ for UPLC system. Also, limit of detection for ENL was 1.848 ng mL−1 and 31.477 ng mL−1 for HCZ, 2.804 ng mL−1 for ENL and 2.943 ng mL−1 for HCZ using HPLC and UPLC, respectively. The proposed methods were validated according to ICH guideline with respect to precision, accuracy, and linearity. Forced degradation studies were also performed for both compounds in bulk drug samples to demonstrate the specificity and stability indicating power of the HPLC method. Comparison of system performance with conventional HPLC was made with respect to analysis time, efficiency, and resolution.

  相似文献   

17.
Xu  Quanyun Alan  Kazerooni  Reza  Thapar  Jay K.  Andersson  Borje D.  Madden  Timothy L. 《Chromatographia》2009,70(9-10):1505-1510

A rapid and reliable UPLC method was developed and validated for the determination of busulfan in human plasma. After protein precipitation, derivatization, and liquid–liquid extraction, separation of derivatized busulfan was achieved on an Acquity BEH C18 column using a gradient mobile phase consisting of a trifluoroacetic acid aqueous solution (0.2%, v/v) and acetonitrile. The column temperature was maintained at 50 °C and UV detection was carried out at 254 nm. The complete analytical run time was 1.3 min, 7-fold faster than our previous LC methodology. Quantification was performed using external standardization and calibration curves were linear (r ≥ 0.999) over the dynamic range of 0.05–5.00 μg mL−1. Intra-day and inter-day coefficients of variation were ≤6.9 and 3.9%, respectively, across the range of concentrations. Accuracy of the analytical method expressed as the relative error percentage was better than 5.4%. LOD and LOQ were 0.013 and 0.025 μg mL−1, respectively. Data obtained using the UPLC method was compared to those obtained from our previously used LC method by Deming regression analysis. The UPLC method was accurate, sensitive, and greatly increased sample analysis throughput as compared to our previous LC methodology allowing for a 4-fold increase in the number of patients who could be monitored during transplant therapy.

  相似文献   

18.
A sensitive and accurate LC method was developed and further validated for the determination of enantiomeric purity of GSK962040. Before separation, a pre-column derivatization procedure was performed. Baseline separation with a resolution higher than 1.9 was accomplished within 15 min using a Chiralpak AD-H (250 × 4.6 mm; particle size 5 μm) column, with n-hexane: 2-propanol (85:15 v/v) as mobile phase at a flow rate of 1 mL min?1. The eluted analytes were subsequently detected with a UV detector at 260 nm. The effects of mobile phase components and temperature on enantiomeric selectivity as well as resolution of enantiomers were thoroughly investigated. The calibration curves were plotted within the concentration range between 4 and 200 μg mL?1 (n = 8), and recoveries between 98.15 and 101.48% were obtained, with relative standard deviation (RSD) lower than 1.42%. The LOD and LOQ for the Boc-GSK962040 were 1.23 and 4.15 μg mL?1 and for its enantiomer were 1.38 and 4.76 μg mL?1, respectively. The developed method was also evaluated and validated by analyzing bulk samples with different enantiomeric ratios of GSK962040. It was demonstrated that the method was accurate, robust and sensitive, and also had practical utilities for real analysis.  相似文献   

19.
Jin  Wei  Yang  Yong-Jian  Wang  Wei-Yu  Ye  Jian-Nong 《Chromatographia》2009,69(11):1221-1226

A suitable method that allows, for the first time, the simultaneous determination of nine antibiotics which may help the therapy of acne vulgaris by rapid liquid chromatography with diode array detection in 7 min is presented in this work. An SB RP18 (50 × 4.6 mm; 1.8 μm particle size) column was used with the mobile phase consisting of a mixture of 0.1 mol L−1 potassium dihydrogen phosphate (pH 2.5) and acetonitrile at the gradient elution program. The correlation coefficients were all above 0.9999 in the linear range between 4–100 μg mL−1, the average spiked recoveries (n = 6) were 92.2–103.2% with RSD ranging from 0.04 to 4.5% depending on the target analytes. The method detection limits were in the range of 0.02–0.2 μg mL−1 in anti-acne cosmetics. The analysis of real cosmetic preparations demonstrated the fitness for the whole analytical procedure. The proposed method appeared therefore as a sound alternative for official testing method, which could overcome the general problems of time consuming, lack of the specificity and precision difficulty.

  相似文献   

20.
Chen  Jing  Gu  Jingkai  Zhao  Rui  Dai  Ronghua  Wang  Jinhui 《Chromatographia》2009,69(3-4):361-363

A new method was performed using on-line coupling of nonchiral reversed-phase liquid chromatography (RP-LC) to circular dichroism (CD) spectroscopy for simultaneous determination of artemisinin and arteannuin B in crude plant extracts of Artemisia annua. Analysis was carried out on an LC–CD system equipped with an Agilent TC-C18 column (4.6 mm I.D. × 200 mm L, 5 μm) using gradient of acetonitrile. The method was validated to be practicable and reliable at alterable wavelength in the ranges of 220–420 nm as desired. LOD and LOQ of artemisinin and arteannuin B were 0.08, 0.26 and 0.31, 1.02 μg mL−1, respectively. It was more sensitive than conventional LC–UV and comparatively cheaper than LC–MS in analysis of TCM.

  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号