1.
Wilforidine is a potentially efficient medicine to cure autoimmune diseases. In this paper, a sensitive and selective liquid chromatographic method coupled with atmospheric -pressure chemical ionization mass spectrometry (LC–APCI–MS/MS) has been developed for quantification of wilforidine in human plasma. Samples were deproteinized with acetonitrile and cleaned by solid-phase extraction. The chromatographic separation was performed on an analytical RRHD C18 column (50 × 2.1 mm) using ammonium acetate solution (10.0 mmol L?1)/acetonitrile (30/70, v/v) as the mobile phase at a flow rate of 0.7 mL min?1. Detection was carried out by the positive multiple reaction monitoring mode with transitions of m/z 780 → 684 for wilforidine, and 646 → 586 for aconitine (internal standard), respectively. The calibration curve was linear (r = 0.9991) in the concentration range of 0.5–100.0 μg L?1 with a lower limit of quantification of 0.5 μg L?1 in plasma. Intra- and inter-day relative standard deviations were less than 6.8 and 13.1 %, respectively, and the recoveries were between 88.0 and 96.0 %. This accurate and highly specific assay provides a useful method for evaluating the pharmacokinetics of wilforidine in human plasma.  相似文献   

2.
Xu  Fan  Xu  Guili  Shang  Beicheng  Yu  Fang 《Chromatographia》2009,69(11):1421-1426

A simple, specific and sensitive liquid chromatographic method has been developed for the assay of ketorolac in human plasma and urine. The clean-up of plasma and urine samples were carried out by protein precipitation procedure and liquid–liquid extraction, respectively. Separation was performed by a Waters sunfire C18 reversed-phase column maintained at 35 °C. The mobile phase was a mixture of 0.02 M phosphate buffer (pH adjusted to 4.5 for plasma samples and to 3.5 for urine samples) and acetonitrile (70:30, v/v) at a flow rate of 1.0 mL min−1. The UV detector was set at 315 nm. Nevirapine was used as an internal standard in the assay of urine sample. The method was validated over the concentration range of 0.05–8 and 0.1–10 μg mL−1 for ketorolac in human plasma and urine, respectively. The limits of detection were 0.02 and 0.04 μg mL−1 for plasma and urine estimation at a signal-to-noise ratio of 3. The limits of quantification were 0.05 and 0.1 μg mL−1 for plasma and urine, respectively. The extraction recoveries were found to be 99.3 ± 4.2 and 80.3 ± 3.7% for plasma and urine, respectively. The intra-day and inter-day standard deviations were less than 0.5. The method indicated good performance in terms of specificity, linearity, detection and quantification limits, precision and accuracy. This assay demonstrated to be applicable for clinical pharmacokinetic studies.

  相似文献   

3.

Liquid chromatography coupled with tandem mass spectrometry for therapeutic drug monitoring of immunosuppressants has been widely adopted in clinical chemistry laboratories. However, UPLC is replacing classical LC techniques, providing higher resolution and speed. We developed and validated an UPLC–MS/MS method for the simultaneous measurement of cyclosporine A, everolimus, sirolimus and tacrolimus concentrations in human blood. Following extraction with a zinc sulfate solution and acetonitrile, the chromatographic separation was achieved using an Acquity® UPLC® BEH™ (2.1 × 30 mm id, 1.7 µm) reverse-phase C18 column, with a water/methanol linear gradient containing 2 mM ammonium acetate with 0.1 % formic acid at a 0.5 mL min−1 flow rate. All immunosuppressants were detected by ESI mass spectrometry in positive ion multiple reaction monitoring mode using mass-to-charge transitions of 1219.8 → 1202.6/1184.4, 975.5 → 908.3/891.6, 931.5 → 864.3/883.3, 821.4 → 768.2/719.9 for cyclosporine A, everolimus, sirolimus and tacrolimus, respectively. Coefficients of variation and relative bias were less than 5.8 and 9.7 % for cyclosporine A, 8.7 and 6.4 % for everolimus, 8.5 and 7.2 % for sirolimus and 6.7 and 4.7 % for tacrolimus. Limits of quantification were 15.4 µg L−1 for cyclosporine A, 1.42 µg L−1 for everolimus, 1.58 µg L−1 for sirolimus and 0.65 µg L−1 for tacrolimus. Mean recoveries were greater than 77.6 % for all immunosuppressants. Evaluation of the matrix effect showed ion suppression for all the immunosuppressants, except for cyclosporine A, which suffered ion enhancement. No carry-over was observed. The validated method appears to be well adapted for therapeutic drug monitoring of multiple immunosuppressants in daily clinical practice.

  相似文献   

4.

A sample preparation method for aflatoxin M1 (AFM1) determination in raw milk was optimized following the quick, easy, cheap, effective, rugged and safe (QuEChERS) strategy, as an alternative to the classic immunoaffinity column clean-up (IAC). The method was adapted to address the complexity of the milk matrix, and to be suitable for final determination by ultra-high performance liquid chromatography coupled to tandem mass spectrometry (UHPLC–MS/MS). This approach proved also to be compatible with the simultaneous extraction of pesticide residues and other contaminants (mycotoxins). Regarding AFM1, satisfactory linearity was achieved and appropriate sensitivity was maintained, using matrix-matched calibration to compensate for the heavy ion suppression. The accuracy and precision, which were determined through recovery studies, were 70–95 %, with the relative standard deviation below 15 % in all of the cases. The limit of detection (LOD, 0.002 μg L−1) and limit of quantification (0.007 μg L−1) are compatible with current worldwide regulations (maximum levels of 0.5 and 0.05 μg L−1). The procedure was applied to samples that were naturally contaminated with a range of AFM1 at LOQ–0.187 μg L−1, with comparable results to IAC clean-up, which was employed as a reference method. Therefore, AFM1 determination in raw milk by UHPLC–MS/MS detection through the present QuEChERS extraction constitutes a reliable alternative to IAC clean-up and exhibits advantages related to cost, accessibility of materials and simplicity of operation.

  相似文献   

5.
Li  Fajie  Zhang  Haiying  Li  Yan  Yu  Yingjia  Chen  Yile  Xie  Meifen  Duan  Gengli 《Chromatographia》2012,75(3-4):187-191

A rapid and accurate size exclusion chromatography method for the simultaneous identification and quantification of dextran 20 and sucrose with optical activity in the lyophilized thrombin powder was developed and validated. The assay was conducted on a Hitachi model D-2000 Elite HPLC system with a TOSOH TSKgel G3000 PWxl column (30 cm × 7.8 mm, 7 μm particle size) and an Alltech 3300 evaporative light scattering detector (ELSD). The mobile phase was acetonitrile–water (46:54, v/v) mixture delivered at a flow rate of 0.7 mL min−1 at 25 °C. The ELSD was operated at a nebulizer-gas flow rate of 2.0 L min−1 and drift tube temperature of 90 °C, and the gain was set at one. Afterward, method validation system for the size exclusion chromatography analysis was developed. The linear range was 0.1–1.6 and 0.1–1.0 g L−1 for dextran 20 and sucrose, respectively, and the detection limits were <0.02 g L−1 for dextran 20 and <0.015 g L−1 for sucrose. Inter-day and intra-day variabilities showed that RSD ranged from 0.27 to 4.20%. Recovery validation showed that average recovery was between 96.00 and 103.98%. The developed analytical procedure was successfully applied to determine the contents of dextran 20 and sucrose in the lyophilized thrombin powder.

  相似文献   

6.
Yang  Xiao-ming  Zhang  Xiu-li  Chen  Yong-chang  Liu  Fang 《Chromatographia》2009,69(5-6):593-596

A sensitive and simple LC method for the quantification of ginkgolic acids in mice plasma has been developed. Following acetonitrile deproteinization, samples were separated on a SinoChrom ODS-AP C18 column. The mobile phase was 3% (v/v) acetic acid water solution–methanol (8:92, v/v) at a flow rate of 1.0 mL min−1. Detection was at 310 nm. Calibration curve was linear over the range of 0.25–50 μg mL−1 with intra- and inter-day precisions (RSD%) of less than 9.5%. The extraction recovery ranged from 87.0 to 90.2% (RSD 2.4–6.4%) for ginkgolic acids. The method was successfully applied to the pharmacokinetic study of ginkgolic acids in mice after oral dosing of 1.0 g kg−1.

  相似文献   

7.
Zhang  Tianhong  Meng  Ping  Kou  Wen  Ma  Rongli  Zhang  Cong  Sun  Yongbin 《Chromatographia》2010,71(11):1101-1105

A specific and sensitive UPLC-MS–MS was developed for the determination of trimetazidine in human plasma. The sample preparation was based on a single-step liquid–liquid extraction with acetic ether. The chromatographic separation was on a C18 analytical column (50 mm × 2.1 mm, 1.7 μm) with acetonitrile and 10 mM ammonium acetate (30:70, v/v) as the mobile phase, and a triple-quadrupole mass spectrometer equipped with an electrospray ionization source (ESI) applied for detection. The method was linear over the concentration ranges of 0.25–100.00 ng mL−1 for trimetazidine, and the lower limit of quantification (LLOQ) was 0.25 ng mL−1. The intra- and inter-day relative standard deviation (RSD) were less than 15% and the relative error (RE) were all within 15%. Finally, this method has been successfully applied to analyze plasma samples from a bioequivalence study with 18 volunteers.

  相似文献   

8.
Tzanis  Lydie  Simon  Patrice  Walcarius  Alain 《Chromatographia》2008,67(11):857-861

A simple liquid chromatographic method was developed for the separation and simultaneous determination of cobalt and nickel as chelates with 1-(2-pyridylazo)-2-naphthol (PAN). The method, using a switching column technique for the on-line purification and separation, enables to reach the sub-microgram per litre concentration level excluding off-line sample treatment with the exception of the derivatization reaction. Two small-sized columns packed with CN- and C4-bonded stationary phases were selected and used considering their complementary behaviour with respect to chelated Co and Ni ions. The analysis was performed within 10 min using an optimised eluent (water–acetonitrile–methanol–tetrahydrofuran, 40:45:10:5, v/v/v/v) containing Tween 40 (10−3 M) and acetate buffer (5 × 10−3 M, pH 4.8). Detection was performed by UV-vis spectrophotometry (λ = 565 nm) permitting to reach quantification limits of 0.9 and 0.5 μg L−1 for Co and Ni, respectively.

  相似文献   

9.
Jia  Yuanwei  Shen  Jie  Xie  Haitang  Liang  Dahu  Zhang  Jinwen  Wang  Youlin  Qiang  Luo 《Chromatographia》2012,75(9-10):527-531

Fudosteine [(-)-(R)-2-amino-3-(3-hydroxypropylthio) propionic acid] is a synthetic derivative of l-cysteine as a novel expectorant. To facilitate pharmacokinetics studies of fudosteine in man, a sensitive and specific LC–MS–MS method for the quantitative detection of fudosteine in human plasma was developed and validated. The method involved the addition of fosfomycin as internal standards, protein-precipitation, HPLC separation, and quantification by MS/MS system using negative electrospray ionization in the multiple reaction monitoring mode. The precursor → product ion transitions were monitored at 177.6 → 90.9 and 136.8 → 78.9 for fudosteine and the IS, respectively. The lower limit of quantitation (LLOQ) was 5 ng mL−1. The calibration curves for fudosteine was linear over a concentration range of 0.005–10 µg mL−1. The intra- and inter-day analyses of QC samples at 0.01, 1, 10 µg mL−1 indicated good precision %RSD between 92.00 and 101.02%. The fudosteine was stable in human plasma stored at room temperature for at least 12 h, 4 °C for at least 12 h, −20 °C for at least 20 days, and at least three freeze–thaw cycles procedures. This accurate and highly specific assay provides a useful method for evaluating the pharmacokinetics of fudosteine in human.

  相似文献   

10.
Batifiban is a new platelet GPIIb/IIIa receptor antagonist. In this work, an analytical method based on liquid chromatography and electrospray ionization tandem mass spectrometry has been firstly developed and validated for the quantitative measurement of batifiban in human plasma to support the investigation of this compound. Separation of analyte and the internal standard eptifibatide was performed on a Thermo HyPURITY C18 column (150 × 2.1 mm, 5 μm) with a mobile phase consisting of formic acid 0.1% (v/v)–acetonitrile (40:60, v/v) at a flow rate of 0.25 mL min?1. The Waters QuattroMicro API triple quadrupole mass spectrometer was operated in multiple reaction monitoring mode via positive electrospray ionization interface using the transition m/z 819.2 → m/z (623.9 + 159.4) for batifiban and m/z 833.4 → m/z (645.7 + 159.3) for IS. The method was linear over the concentration range of 2.45–5,000 μg L?1. The intra- and inter- day precisions were less than 15% in terms of relative standard deviation, and the accuracy was within 8.5% in terms of relative error (RE). The lower limit of quantification (LLOQ) was identifiable and reproducible at 2.45 μg L?1 with acceptable precision and accuracy. The validated method offered sensitivity and wide linear concentration range. This method was successfully applied for the evaluation of pharmacokinetics of batifiban afer single oral doses of 55, 110 and 220 μg kg?1 batifiban to 36 Chinese healthy volunteers.  相似文献   

11.

A fast gas chromatographic–mass spectrometric (GC–MS) method is proposed for pesticide multiresidue analysis of apples. The QuEChERS method was used for sample preparation. GC–MS analysis was performed with a PTV, an autoinjector, and a quadrupole benchtop MS detector. Electron-impact ionization (70 eV) was used with two modes of selected ion monitoring. Compounds were separated under temperature-programmed conditions on a narrow-bore diphenyldimethylsiloxane column. In one chromatographic run 61 pesticides of different chemical classes, and triphenyl phosphate as internal standard, were determined in 11 min. Calibration was performed with matrix-matched standard solutions and response to the pesticides was a linear function of concentration in the range 1–500 ng mL−1 (equivalent to 1–500 μg kg−1 in real samples). High values of the determination coefficients (R 2; 0.9900–1.0000) were obtained for most of the pesticides. Limits of detection and quantification were determined. When the method was used for analysis of pesticide residues in real samples, five pesticides were detected at concentrations in the range 1.00–21.47 μg kg−1. Repeatability of measurements, expressed as relative standard deviations of absolute peak areas, normalized relative to TPP, and of the concentrations determined, met the EU criterion of RSD ≤ 20%. Use of the internal standard moderately improved quantitative results.

  相似文献   

12.
Zhang  Wei-Dong  Qi  Lian-Wen  Yang  Xiao-Lin  Lu  Yao-Wen  Li  Ping  Yang  Zhong-Lin 《Chromatographia》2008,67(11):1021-1022

A simple, sensitive, and validated liquid chromatographic method has been developed for the determination of tectorigenin in rat plasma and application to a pharmacokinetic study after oral administration of tectorigenin or its prodrug tectoridin. The analysis was performed on a Kromasil C18 analytical column using gradient elution with acetonitrile 0.1% phosphonic acid water at 0.8 mL min−1. The detection wavelength for UV detection was set at 264 nm. The established method was fully validated with parameters as follows: the intra- and inter-day assay precisions (CV) of three analytes were in the range of 4.2–13.3% and accuracies were between 98.0 and 107.5%; the calibration curve was linear with r 2 > 0.99 over a concentration range of 0.02–2 μg mL−1; the lower limit of quantification was 0.02 μg mL−1; tectorigenin showed stable in rat plasma after 12 h incubation at room temperature, 15 days storage at −80 °C and three freeze/thaw cycles, as well as in reconstitute buffer for 24 h at 25 °C; and the mean recoveries of tectorigenin were 92.3 ± 3.2, 95.5 ± 2.9 and 94.5 ± 3.0% with quality control levels of 0.02, 0.2 and 2 μg mL−1, respectively. In conclusion, this method is simple, economic, and sensitive enough for in vivo pharmacokinetic studies of tectorigenin.

  相似文献   

13.
Gu  Jifeng  Chen  Nianzu  Yan  Jingchao  Huang  Taomin  Wang  Donglei  Lai  Yonghua 《Chromatographia》2009,70(11):1709-1713

A sensitive and specific high-performance liquid chromatography–tandem mass spectrometry method has been developed and validated for the determination of clonazepam in rat plasma. Clonazepam and internal standard diazepam were extracted from plasma samples by a single-step protein precipitation. The chromatographic separation was performed on a Dikma ODS-C18 reversed-phase column at 40 °C. The mobile phase composed of a premix of solvent A (0.1% formic acid–4 mM ammonium acetate–water)–solvent B (acetonitrile) (13:87, v/v) at a flow-rate of 0.7 mL min−1. Positive electrospray ionization was utilized as the ionization source. Clonazepam and the internal standard were determined using multiple reaction monitoring of precursor → product ion transitions at m/z 316.0 → 270.0 and m/z 285.1 → 193.2, respectively. The lower limit of quantification was 0.25 ng mL−1 using 50 μL plasma samples and the linear calibration range was from 0.25 to 128 ng mL−1. The within- and between-batch RSDs were lower than 15% and the relative recoveries of clonazepam ranged from 97.4 to 104.7%. The mean extraction recoveries of clonazepam and IS were 79.7 and 77.6%, respectively. The method has been successfully applied to the pharmacokinetic studies in rat after oral administration of clonazepam.

  相似文献   

14.
Ding  Chenxu  Wang  Lingyun  Tian  Chunliang  Li  Yulin  Sun  Zhiwei  Wang  Honglun  Suo  Yourui  You  Jinmao 《Chromatographia》2008,67(11):893-903

A sensitive and selective liquid chromatographic tandem mass spectrometric (LC–MS–MS) method was developed for simultaneous identification and quantification of tamsulosin and dutasteride in human plasma, which was well applied to clinical study. The method was based on liquid–liquid extraction, followed by an LC procedure with a Gemini C-18, 50 mm × 2.0 mm (3 μm) column and using methanol:ammonium formate (97:3, v/v) as the mobile phase. Protonated ions formed by a turbo ionspray in positive mode were used to detect analytes and internal standard. MS–MS detection was by monitoring the fragmentation of 409.1 → 228.1 (m/z) for tamsulosin, 529.3 → 461.3 (m/z) for dutasteride and 373.2 → 305.3 (m/z) for finasteride (IS) on a triple quadrupole mass spectrometer. The lower limit of quantification for both tamsulosin and dutasteride was 1 ng mL−1. The proposed method enables the unambiguous identification and quantification of tamsulosin and dutasteride for clinical drug monitoring.

  相似文献   

15.
Fang  Lina  Wang  Qiudi  Bi  Kaishun  Zhao  Xu 《Chromatographia》2016,79(23):1659-1663

A sensitive and simple HPLC method for simultaneous determination of PAC-1 (first procaspase-activating compound), phenol red, and permeability markers (carbamazepine and furosemide) in perfusion samples was developed and validated to assess intestinal absorption of PAC-1 using single-pass intestinal perfusion technique (SPIP) in rats. The chromatographic separation was carried out on a Kromasil C18 column (150 mm × 4.6 mm, 5 μm) with acetonitrile–methanol–30 mmol L−1 phosphate buffer (pH 3.0, 25:10:65, v/v/v) as mobile phase at a flow rate of 1.0 mL min−1, and the wavelength of the UV detector was set at 281 nm. The calibration curves were linear in the ranges of 2.40–48.0 μg mL−1 for PAC-1; 3.60–72.0 μg mL−1 for carbamazepine; 3.20–64.0 μg mL−1 for furosemide, and 4.80–96.0 μg mL−1 for phenol red (r > 0.999). Both the intra- and inter-day precisions (RSD%) of all analytes were less than 6.8 % at three concentration levels, while accuracy ranged from 95.4 to 104.5 %. Data obtained in all method validation studies indicated that the method was suitable for the intended purpose. The effective permeability values (P eff) considering water flux with the help of non-permeable marker phenol red was calculated to be 0.42 × 10−4, 0.62 × 10−4, 0.32 × 10−4 cm s−1 for PAC-1; 0.72 × 10−4, 0.77 × 10−4, 0.52 × 10−4 cm s−1 for carbamazepine; 0.20 × 10−4, 0.16 × 10−4, 0.12 × 10−4 cm s−1 for furosemide in duodenum, jejunum and ileum, respectively. The P eff value can be increased by co-perfusion with verapamil, indicating that absorption of PAC-1 is efficiently transported by P-glycoprotein (P-gp) in the gut wall.

  相似文献   

16.
Wu  Cong-Ming  Li  Yan  Shen  Jian-Zhong  Cheng  Lin-Li  Li  Yan-Shen  Yang  Chun-Yan  Feng  Pei-Sheng  Zhang  Su-Xia 《Chromatographia》2009,70(11):1605-1611

A sensitive and reliable method by liquid chromatography–tandem mass spectrometry was developed for the simultaneous determination of carbadox, mequindox, olaquindox and quinocetone in swine feed. The analytes were extracted from swine feed with acetonitrile/water (60:40, v/v), and then further purified by solid-phase extraction using Oasis HLB cartridges. The mean recovery values ranged from 83–108%, and intra-day and inter-day variation were <10.8 and 9.6%, respectively. The limits of quantification for the four compounds were <20 μg kg−1. This procedure is applicable for detecting the four quinoxaline-1,4-dioxides in swine feed.

  相似文献   

17.
Kim  Bora  Shin  Hyun-Suk  Kim  Jung-Ryul  Lim  Kyung-Soo  Yoon  Seo Hyun  Yu  Kyung-Sang  Shin  Sang-Goo  Jang  In-Jin  Cho  Joo-Youn 《Chromatographia》2012,75(11):671-677

A simple, rapid and sensitive LC–MS/MS method in positive ion mode was developed and validated to determine CKD-501, lobeglitazone, in human plasma and urine using glipizide as an internal standard (IS). Lobeglitazone is a novel thiazolidinedione (TZDs)-based peroxisome proliferator-activated receptor (PPAR) agonist, used for the management of type-2 diabetes. After mixing the IS, dissolved in acetonitrile, with a plasma or urine sample containing lobeglitazone, 10 μL of supernatant was injected into the LC–MS/MS system. Quantification was performed in the multiple reaction monitoring (MRM) mode using transition of 481.5 → 152.2 (m/z) for lobeglitazone and 446.1 → 321.2 (m/z) for the IS. The method showed good linearity over concentration ranges of 0.5–1,000 ng mL−1 for plasma and 0.2–250 ng mL−1 for urine (r 2 ≥ 0.9996). The mean percent extraction recovery of lobeglitazone was 90.8 % for plasma and 87.3 % for urine, while the recoveries of the IS were greater than 86.4 % for both. The intra-day and inter-day precision of plasma ranged from 1.1 to 3.7 and 2.5 to 3.3 % (RSD), respectively, and the intra- and inter-day precision of urine ranged from 1.5 to 2.7 and 3.2 to 3.5 %, respectively. This method is simple, sensitive, and applicable for the pharmacokinetic study of lobeglitazone in human plasma. Most of the urine concentrations of lobeglitazone were below the LLOQ because the lobeglitazone is extensively metabolized.

  相似文献   

18.
Fan Xu  Guili Xu  Beicheng Shang  Fang Yu 《Chromatographia》2009,69(11-12):1421-1426
A simple, specific and sensitive liquid chromatographic method has been developed for the assay of ketorolac in human plasma and urine. The clean-up of plasma and urine samples were carried out by protein precipitation procedure and liquid–liquid extraction, respectively. Separation was performed by a Waters sunfire C18 reversed-phase column maintained at 35 °C. The mobile phase was a mixture of 0.02 M phosphate buffer (pH adjusted to 4.5 for plasma samples and to 3.5 for urine samples) and acetonitrile (70:30, v/v) at a flow rate of 1.0 mL min?1. The UV detector was set at 315 nm. Nevirapine was used as an internal standard in the assay of urine sample. The method was validated over the concentration range of 0.05–8 and 0.1–10 μg mL?1 for ketorolac in human plasma and urine, respectively. The limits of detection were 0.02 and 0.04 μg mL?1 for plasma and urine estimation at a signal-to-noise ratio of 3. The limits of quantification were 0.05 and 0.1 μg mL?1 for plasma and urine, respectively. The extraction recoveries were found to be 99.3 ± 4.2 and 80.3 ± 3.7% for plasma and urine, respectively. The intra-day and inter-day standard deviations were less than 0.5. The method indicated good performance in terms of specificity, linearity, detection and quantification limits, precision and accuracy. This assay demonstrated to be applicable for clinical pharmacokinetic studies.  相似文献   

19.
A simple and selective reversed-phase stability-indicating liquid chromatographic method has been developed and validated for the determination of daclatasvir in drug substance and drug product. Daclatasvir was subjected to acidic, alkaline, oxidative, thermal and photo-degradation study. The LC method was based on isocratic elution of daclatasvir and its degradation products on a reversed-phase C18 Hypersil column using a mobile phase consisting of phosphate buffer (10 mM, 1 mL triethylamine L?1): acetonitrile (60:40 v/v) at a flow rate of 2 mL min?1. Quantitation was achieved with UV detection at 312 nm. Linearity, accuracy, and precision were found to be acceptable over the concentration range of 0.75–120 μg mL?1, with regression coefficient value of 0.9999, and with limit of detection and quantitation of 0.148 and 0.447 μg mL?1, respectively. Peak purity was checked for principle drug and its alkali induced degradation product, and the pathway of alkaline hydrolysis of daclatasvir was suggested by LC/MS.  相似文献   

20.

An LC-DAD method was developed for determination of lobeline from in vitro and in vivo cultures of Lobelia inflata. Samples were extracted with 0.1 N HCl–acetonitrile (1:1, v/v), and purified by solid-phase extraction. Optimized conditions resulted in high recovery. LC separations were performed on an Eurosphere C8 reversed-phase column using 30:70 (v/v) acetonitrile–0.1% trifluoroacetic acid as a mobile phase. Quantitative determination of lobeline was performed by external standard method at 250 nm, in the range of 2.4–80 μg mL−1. Validation studies proved that the repeatability of the method was good and the recovery was satisfactory. In vitro organized cultures contained considerable amount of lobeline (herb: 175 μg g−1, root: 100 μg g−1). When these cultures were transplanted into the open field, the lobeline content increased significantly (herb: 323 μg g−1, root: 833 μg g−1). Plants obtained from seed propagation contained 382 μg g−1 lobeline in the herb. For direct characterization of di-substituted piperidine alkaloids in extracts of L. inflata, tandem mass spectrometric method was developed using electrospray ionization. Analysis was performed in the positive ion mode on a triple quadropole LC–MS system. LC separations were achieved on Eurosphere C8 column with a modified mobile phase (acetonitrile–30 mM ammonium formate, pH 2.80) to ensure proper molecular ionization. The identification and structural elucidation of the alkaloids were performed by comparing their changes in molecular mass (ΔM), full-scan MS–MS spectra with those of lobeline, norlobelanine and lobelanidine. These alkaloids and ten other derivatives were identified in the plant extracts. Three piperidine alkaloids were reported in L. inflata for the first time.