共查询到20条相似文献,搜索用时 15 毫秒
1.
Jing-Juan Xu Xiao-Qiang Zhang Zhi-Hao Yu Hui-Qun Fang Hong-Yuan Chen 《Analytical and bioanalytical chemistry》2001,369(6):486-490
An amperometric glucose biosensor was successfully developed by electrochemical polymerization of p-chlorophenol (4-CP) at a Pt electrode in the presence of glucose oxidase. The amperometric response of this biosensor to hydrogen peroxide, formed as the product of enzymatic reaction, was measured at a potential of 0.6 V (vs. SCE) in phosphate buffer solution. The performances of sensors, prepared at different monomer concentrations and polymerization potentials, were investigated in detail. The biosensor prepared under optimal conditions had a linear response to glucose ranging from 2.5 × 10–4 to 1.5 × 10–2 mol L–1 with a correlation coefficient of 0.997 and a response time of less than 2 s. Substrate selectivity of the polymer-based enzyme electrode was tested for coexisting interferents such as uric acid and ascorbic acid, and no discernible response was observed. After 90 days, the response of the biosensor remained almost unchanged, indicating very good stability. 相似文献
2.
A novel biosensor for phenols was constructed by immobilizing polyphenol oxidase (PPO) into polyaniline-polyacrylonitrile composite matrix. The sensing film was prepared by electropolymerization of aniline into polyacrylonitrile (PAN)-coated platinum electrode in the presence of PPO. The scanning electron micrographs (SEM) showed that PAN had microporous structure and polyaniline and the enzyme could co-intercalated into PAN matrix. The obtained biosensor exhibited high sensitivity and excellent stability, which had no apparent loss of activity after 100 consecutive measurements and intermittent usage for 8 months with storage in a phosphate buffer at 4 degrees C. The construction and operational conditions of the enzyme electrode were optimized. The sensitivities of the enzyme electrode for phenol, p-cresol, m-cresol and catechol were 0.96, 1.38, 1.5 and 2.03 AM(-1)cm(-2), respectively. 相似文献
3.
Xiaotian Tian Sai Lian Limin Zhao Xiaomei Chen Zhiyong Huang Xi Chen 《Journal of Solid State Electrochemistry》2014,18(9):2375-2382
A novel electrochemiluminescence (ECL) biosensor based on platinum nanoflowers (PtNFs)/graphene oxide (GO)/glucose oxidase (GODx) was discovered for glucose detection. PtNFs/GO was synthesized using a nontoxic, rapid, one-pot and template-free method and characterized by transmission electron microscopy (TEM) and high-resolution TEM techniques. The as-prepared PtNFs/GO with clean surface and multiporous structure was used to assemble GODx to form a glucose biosensor. Based on ECL results, the PtNFs/GO/GODx film-modified electrode displayed a high electrocatalytic activity towards the oxidation of glucose, which generated hydrogen peroxide (H2O2) to react with the luminol radicals thus enhanced the luminol ECL. Under the optimized conditions, two linear regions of ECL intensity to glucose concentration were valid in the range from 5 to 80 μmol/L (r?=?0.9957) and 80 to 1,000 μmol/L (r?=?0.9909) with a detection limit (S/N?=?3) of 2.8 μmol/L. In order to verify the reliability, the thus-fabricated biosensor was applied to determine the glucose concentration in glucose injection, glucose functional drink, and blood serum. The results indicated that the proposed biosensor presented good characteristics in terms of high sensitivity and good reproducibility for glucose determination, promising the applicability of this sensor in practical analysis. 相似文献
4.
5.
An amperometric glucose biosensor is developed that is based on immobilization of glucose oxidase (GOD) in a composite film of poly(o-aminophenol) (POAP) and carbon nanotubes (CNT), which are electrochemically co-polymerized at a gold (Au) electrode. Because of the high surface per volume ratio and excellent electrical conductivity of CNT, the biosensor based on an Au/POAP/CNT/GOD electrode has lower detection limit (0.01 mM), larger maximum response current (0.24 mA cm(-2)) and higher sensitivity (11.4 mA M(-1) cm(-2)) than the values of the biosensor based on an Au/POAP/GOD electrode. Additionally, the biosensor shows fast response time, large response current, and good anti-interferent ability for ascorbic acid, uric acid and acetaminophen. Good reproducibility and stability of the biosensor are also observed. 相似文献
6.
We have developed an enzymatic glucose biosensor that is based on a flat platinum electrode which was covered with electrophoretically deposited rhodium (Rh) nanoparticles and then sintered to form a large surface area. The biosensor was obtained by depositing glucose oxidase (GOx), Nafion, and gold nanoparticles (AuNPs) on the Rh electrode. The electrical potential and the fractions of Nafion and GOx were optimized. The resulting biosensor has a very high sensitivity (68.1 μA mM?1 cm?2) and good linearity in the range from 0.05 to 15 mM (r?=?0.989). The limit of detection is as low as 0.03 mM (at an SNR of 3). The glucose biosensor also is quite selective and is not interfered by electroactive substances including ascorbic acid, uric acid and acetaminophen. The lifespan is up to 90 days. It was applied to the determination of glucose in blood serum, and the results compare very well with those obtained with a clinical analyzer. Figure
An enzymatic glucose biosensor was prepared based on rhodium nanoparticle modified Pt electrode and glucose oxidase immobilized in gold nanoparticles and Nafion composite film. The electrode showed a good response to glucose. The sensor was applied to the determination of glucose in blood serum. 相似文献
7.
Platinum was incorporated into a polypyrrole/glucose oxidase electrode by immersion in a hexachloroplatinate(IV) solution after electrochemical oxidation of the polypyrrole film; dispersed platinum was then formed by electrochemical reduction. The platinized electrode reproducibly yielded a response to glucose (20 mM) which was typically about 40% higher than that obtained in the absence of platinum microparticles in the polypyrrole/glucose oxidase film. 相似文献
8.
The construction of a l-lysine biosensor on a Si-gold strip electrode (SGSE) is described in this study. The construction comprises (a) the formation of poly(o-phenylenediamine, o-PD) membrane on the electrode surface via electropolymerization and (b) the immobilization of lysine oxidase on the gold/poly(o-PD) electrode with glutaraldehyde. The behavior of the gold/poly(o-PD) electrode against H(2)O(2) and lysine, as well as the repeatability of the electropolymerization and the time stability of the polymer were studied. The study showed that the electropolymerization procedure is repeatable, and that the polymer is quite stable for at least 40 days. The biosensor showed a linear calibration curve in the range 0.01-1x10(-5) M (0.1-10 muM) lysine. The interfering effect of other amino acids on the biosensor performance was also studied and amperometric selectivity coefficients were calculated. The biosensor responded mainly against tyrosine and cysteine, while the response to phenylalanine, arginine, histidine and ornithine was very low. By changing the electropolymerization conditions, the effect of interferents was further reduced. 相似文献
9.
Gao Q Guo Y Liu J Yuan X Qi H Zhang C 《Bioelectrochemistry (Amsterdam, Netherlands)》2011,81(2):109-113
A glucose biosensor based on a nanocomposite made by layer-by-layer electrodeposition of the redox polymer into a multilayer containing glucose oxidase (GOx) and single-walled carbon nanotubes (SWCNT) on a screen-printed carbon electrode (SPCE) surface was developed. The objectives of the electrodeposition of redox polymer are to stabilize further the multilayer using a coordinative cross-linked redox polymer and to wire the GOx. The electrochemistry of the layer-by-layer assembly of the GOx/SWCNT/redox polymer nanocomposite was followed by cyclic voltammetry. The resultant biosensor provided stable and reproducible electrocatalytic responses to glucose, and the electrocatalytic current for glucose oxidation was enhanced with an increase in the number of layers. The biosensor displayed a linear range from 0.5 to 6.0mM, a sensitivity of 16.4μA/(mMcm(2)), and a response time of about 5s. It shows no response to 0.05mM of ascorbic acid, 0.32mM of uric acid and 0.20mM of acetaminophen using a Nafion membrane covering the nanocomposite-modified electrode surface. 相似文献
10.
A novel glucose biosensor is presented as that based on a glassy carbon electrode modified with hollow gold nanoparticles (HGNs) and glucose oxidase. The sensor exhibits a better differential pulse voltammetric response towards glucose than the one based on conventional gold nanoparticles of the same size. This is attributed to the good biological conductivity and biocompatibility of HGNs. Under the optimal conditions, the sensor displays a linear range from 2.0?×?10?6 to 4.6?×?10?5?M of glucose, with a detection limit of 1.6?×?10?6?M (S/N?=?3). Good reproducibility, stability and no interference make this biosensor applicable to the determination of glucose in samples such as sports drinks. Figure
A novel glucose biosensor was prepared based on glucose oxidase, hollow gold nanoparticles and chitosan modified glassy carbon electrode. The electrode showed a good response for the glucose. The sensor has been verified by the determination of glucose in sport drink 相似文献
11.
A novel glucose biosensor, based on the modification of well-aligned polypyrrole nanowires array (PPyNWA) with Pt nanoparticles (PtNPs) and subsequent surface adsorption of glucose oxidase (GOx), is described. The distinct differences in the electrochemical properties of PPyNWA–GOx, PPyNWA–PtNPs, and PPyNWA–PtNPs–GOx electrodes were revealed by cyclic voltammetry. In particular, the results obtained for PPyNWA–PtNPs–GOx biosensor showed evidence of direct electron transfer due mainly to modification with PtNPs. Optimum fabrication of the PPyNWA–PtNPs–GOx biosensor for both potentiometric and amperometric detection of glucose were achieved with 0.2 M pyrrole, applied current density of 0.1 mA cm−2, polymerization time of 600 s, cyclic deposition of PtNPs from −200 mV to 200 mV, scan rate of 50 mV s−1, and 20 cycles. A sensitivity of 40.5 mV/decade and a linear range of 10 μM to 1000 μM (R2 = 0.9936) were achieved for potentiometric detection, while for amperometric detection a sensitivity of 34.7 μA cm−2 mM−1 at an applied potential of 700 mV and a linear range of 0.1–9 mM (R2 = 0.9977) were achieved. In terms of achievable detection limit, potentiometric detection achieved 5.6 μM of glucose, while amperometric detection achieved 27.7 μM. 相似文献
12.
Poly(ethylene glycol) methyl ether methacrylate (PEGMEM) microparticles were synthesized and glucose oxidase (GOx) was immobilized within the microparticles. An amperometric biosensor was fabricated using the microparticles with GOx as biological component. The enzyme immobilization method was optimized by investigating the influence of monomer concentration and cross-linker content used in the preparation of the microparticles in the response of the biosensor. The best analytical results were obtained with the microparticles prepared with 0.21 M PEGMEM and 0.74% cross-linking. Furthermore, we have investigated the influence on the biosensor behaviour of parameters such as working potential, pH, temperature and enzymatic load. In addition, analytical properties such as sensitivity, linear range, response time and detection limit were determined. The biosensor was used to determine glucose in human serum samples and to avoid common interferents present in human serum such as uric and ascorbic acids. A Nafion layer was deposited on the electrode surface with satisfactory results. The useful lifetime of the biosensor was at least 520 days. 相似文献
13.
14.
15.
A poly(nickel(II) tetrasulfophthalocyanine)/multi-walled carbon nanotubes composite modified electrode (polyNiTSPc/MWNTs) was fabricated by electropolymerization of NiTSPc on MWNTs-modified glassy carbon electrode (GCE). The modified electrode was found to be able to greatly improve the emission of luminol electrochemiluminescence (ECL) in a solution containing hydrogen peroxide. Glucose oxidase (GOD) was immobilized on the surface of polyNiTSPc/MWNTs modified GC electrode by Nafion to establish an ECL glucose sensor. Under the optimum conditions, the linear response range of glucose was 1.0 × 10−6 to 1.0 × 10−4 mol L−1 with a detection limit of 8.0 × 10−8 mol L−1 (defined as the concentration that could be detected at the signal-to-noise ratio of 3). The ECL sensor showed an outstanding well reproducibility and long-term stability. The established method has been applied to determine the glucose concentrations in real serum samples with satisfactory results. 相似文献
16.
The use of hydrogenated platinum electrodes allows observation of the electroreduction of some oxygenated ions, which is otherwise masked by the reduction of the hydrogen ion. The present paper deals with the reduction of molybdenum(VI) at a prehydrogenated platinum electrode in acid solutions. The experimental conditions for the electrode hydrogenation process are the following: 90 min at a cathodic current density of about 7 A/cm(2) for microelectrodes with an area of 0.02-0.03 cm(2); about 120 min at a current density of 1.5-2 A/cm(2) for microelectrodes with an area of 0.25-0.35 cm(2). The reduction of molybdenum(VI) in 0.8-1.6M H(2)SO(4) occurs in two consecutive steps: the more cathodic wave [Mo(V) to Mo(III)] is for the most part masked by the reduction of the solvent; the less cathodic wave [Mo(VI) to Mo(V)] takes place at E(1 2 ) values of about +0.07 V, is well shaped, diffusion-controlled and usable for the determination of molybdenum down to 4 x 10(-5)M or 6 x 10(-5)M if a rotating disk electrode is used. Interferences from diverse ions have been studied. A generalization of the effect of electrode hydrogenation on the reduction of those oxygenated ions so far studied [i.e., vanadium(IV), uranium(VI) and molybdenum(VI)] is presented. 相似文献
17.
An amperometric choline biosensor was developed by immobilizing choline oxidase (ChOx) in a layer-by-layer (LBL) multilayer film on a platinum (Pt) electrode modified with Prussian blue (PB). 6-O-Ethoxytrimethylammoniochitosan chloride (EACC) was used to prepare the ChOx LBL films. The choline biosensor was used at 0.0 V versus Ag/AgCl to detect choline and exhibited good characteristics such as relative low detection limit (5 × 10−7 M), short response time (within 10 s), high sensitivity (88.6 μA mM−1 cm−2) and a good selectivity. The results were explained based on the ultrathin nature of the LBL films and the low operating potential that could be due to the efficient catalytic reduction of H2O2 by PB. In addition, the effects of pH, temperature and applied potential on the amperometric response of choline biosensor were evaluated. The apparent Michaelis-Menten constant was found to be (0.083 ± 0.001) ×10−3 M. The biosensor showed excellent long-term storage stability, which originates from a strong adsorption of ChOx in the EACC multilayer film. When the present choline biosensor was applied to the analysis of phosphatidylcholine in serum samples, the measurement values agreed satisfactorily with those by a hospital method. 相似文献
18.
A carbon-paste chemically modified with glucose oxidase and a ferrocene-containing siloxane polymer was further modified by coating the electrode surface with a poly(ester-sulfonic acid) cation-exchanger, Eastman AQ-29D. The polymer is obtained as a homogeneous aqueous dispersion at pH 5–6; when dried, the polymer coating is not water-soluble. The coating was shown not to be detrimental to the enzyme activity but to prevent electrochemically active anionic interferents such as ascorbate and urate from reaching the electrode surface. The polymer coating also prevented glucose oxidase from leaking out of the carbon paste into the contacting solution and protected the electrode surface from fouling agents present in urine and bovine serum albumin. Uncoated electrodes lost some 10-2-15% of their original response to glucose after storage in buffer for three weeks whereas the response of the coated electrodes remained constant. Calibration curves for glucose were strictly linear up to about 5 mM for uncoated and up to 20 mM for coated electrodes. The response current to glucose was not decreased after coating. 相似文献
19.
Junjie Fei Yunhua Wu Xiaobo Ji Jing Wang Shengshui Hu Zhiqiang Gao 《Analytical sciences》2003,19(9):1259-1263
In this paper, we described a glucose biosensor based on the co-electrodeposition of a poly(vinylimidazole) complex of [Os(bpy)2Cl](+/2+) (PVI-Os) and glucose oxidase (GOX) on a gold electrode surface. The one-step co-electrodeposition method provided a better control on the sensor construction, especially when it was applied to microsensor construction. The modified electrode exhibited the classical features of a kinetically fast redox couple bound to an electrode surface and the redox potential of the redox polymer/enzyme film was 0.14 V (vs. SCE). For a scan rate of up to 200 mV s(-1), the peak-to-peak potential separation was less than 25 mV. In the presence of glucose, a typical catalytic oxidation current was observed, which reached a plateau at 0.25 V (vs. SCE). Under the optimal experimental conditions, the steady-state electrooxidation current measured at 0.30 V (vs. SCE) was linear to the glucose concentration in the range of 0-30 mM. Successful attempts were made in blood sample analysis. 相似文献
20.
Sulfite oxidase is immobilized on collagen membrane at the surface of a platinum electrode and catalyzes the oxidation of sulfite to sulfate with stoichiometric production of hydrogen peroxide. The hydrogen peroxide is detected amperometically at the platinum electrode at an applied potential of 700 mV. The system responds linearly to sulfite in the range 1–150 μM, with a detection limit of 0.2 μM. The enzyme retains over 95% of its activity for three weeks if stored at ?20° C when the probe is not in use. 相似文献