共查询到20条相似文献,搜索用时 15 毫秒
1.
在T形微通道中,以错流剪切的分散方式实现了微米级分散气泡的制备,并以NaOH水溶液吸收CO2为对象,考察了气.液微分散体系的分散规律和传质性能.通过考察两相流速对气泡分散尺寸的影响,建立了预测气泡形成尺寸的数学模型.根据气泡的初始分散尺寸、流动阶段的体积变化以及传质完成后的尺寸,首次测定和区分了气泡形成阶段和运动阶段的传质量,建立了原位测定气泡分散流传质系数札的方法,并考察了两相流量对札的影响.结果表明,由于微通道中气泡的形成时间很短,形成阶段的传质量在总传质量中所占的比例很低.气泡分散流的传质系数主要受液相流量的影响,气相流量的影响基本可以忽略.基于实验结果,建立了计算传质系数鼠的无因次准数关联,计算结果与实验结果符合良好. 相似文献
2.
We report how a nominally symmetric microfluidic junction can be used to sort all bubbles of an incoming train exclusively into one of its arms. The existence of this "filter" regime is unexpected, given that the junction is symmetric. We analyze this behavior by quantifying how bubbles modulate the hydrodynamic resistance in microchannels and show how speeding up a bubble train whilst preserving its spatial periodicity can lead to filtering at a nominally symmetric junction. We further show how such an asymmetric traffic of bubble trains can be triggered in symmetric geometries by identifying conditions wherein the resistance to flow decreases with an increase in the number of bubbles in the microchannel and derive an exact criterion to predict the same. 相似文献
3.
We report an analysis of pressure-driven bubble elimination for a gas-permeable microfluidic device. In this study, we described bubble elimination in a microfluidic device employing a gas permeation model and calculated the removal efficiency of bubbles. The correction factor for the simplified model was estimated with respect to the applied pressure. Based on the established model, the required time to remove a trapped bubble with a certain area was shown to be within an error of 11.58% by comparison with experimental results. Exploiting the model equation, we were able to completely remove the air bubbles appearing during the process of filling a microfluidic device with an aqueous solution. 相似文献
4.
In a microfluidic chamber, unwanted formation of air bubbles is a critical problem. Here, we present a hydrophilic strip array that prevents air bubble formation in a microfluidic chamber. The array is located on the top surface of the chamber, which has a large variation in width, and consists of a repeated arrangement of super‐ and moderately hydrophilic strips. This repeated arrangement allows a flat meniscus (i.e. liquid front) to form when various solutions consisting of a single stream or two parallel streams with different hydrophilicities move through the chamber. The flat meniscus produced by the array completely prevents the formation of bubbles. Without the array in the chamber, the meniscus shape is highly convex, and bubbles frequently form in the chamber. This hydrophilic strip array will facilitate the use of a microfluidic chamber with a large variation in width for various microfluidic applications. 相似文献
5.
We report here the sonoporation of HL60 (human promyelocytic leukemia) suspension cells in a microfluidic confinement using a single laser-induced cavitation bubble. Cavitation bubbles can induce membrane poration of cells located in their close vicinity. Membrane integrity of suspension cells placed in a microfluidic chamber is probed through either the calcein release out of calcein-loaded cells or the uptake of trypan blue. Cells that are located farther away than four times Rmax (maximum bubble radius) from the cavitation bubble center remain fully unaffected, while cells closer than 0.75 Rmax become porated with a probability of >75%. These results enable us to define a distance of 0.75 Rmax as a critical interaction distance of the cavitation bubble with HL60 suspension cells. These experiments suggest that flow-induced poration of suspension cells is applicable in lab-on-a-chip systems, and this might be an interesting alternative to electroporation. 相似文献
6.
Xianwu Cao Junjie Peng Xinglei Fang Zhitao Yang Zicen Liao Zhibin Yan Chuanxia Jiang Bin Liu He Zhang 《Journal of polymer science. Part A, Polymer chemistry》2020,58(13):1810-1824
The quality of microcapsules directly determines the performance of microcapsule-based functional materials, such as self-healing materials. How to achieve high-quality microcapsules depends on not only the selected microencapsulation technique but also the process regulation. Herein, using tetraethylenepentamine (TEPA) as the core target to be encapsulated by a novel microencapsulation technique through integrating microfluidic T-junction and interfacial polymerization, this investigation studied how the process parameters influence the microencapsulation process and the quality of the synthesized microcapsules regarding the size, morphology, shell structure, and composition. The studied parameters include the solvent type and surfactant concentration in the co-flow solution, the fed volume of the co-flow solution, the types of the solvent, catalyst, and shell-forming monomer in the reaction solution for the shell-growth stage, and the reaction temperature at the shell-growth stage. The influence mechanisms were established based on the observations, and the optimized parameter combination for the process was achieved. Through the parametric study for the microencapsulation technique, this study also lays a solid foundation for the technique to fabricate microcapsules containing other functional substances with high quality. 相似文献
7.
An active bubble trap and debubbler for microfluidic systems 总被引:2,自引:0,他引:2
We present a novel, fully integrated microfluidic bubble trap and debubbler. The 2-layer structure, based on a PDMS valve design, utilizes a featured membrane to stop bubble progression through the device. A pneumatic chamber directly above the trap is evacuated, and the bubble is pulled out through the gas-permeable PDMS membrane. Normal device operation, including continuous flow at atmospheric pressure, is maintained during the entire trapping and debubbling process. We present a range of trap sizes, from 2 to 10 mm diameter, and can trap and remove bubbles up to 25 muL in under 3 h. 相似文献
8.
On‐chip generation of pressure gradients via electrokinetic means can offer several advantages to microfluidic assay design and operation in a variety of applications. In this article, we describe a simple approach to realizing this capability by employing a polyacrylamide‐based gel structure fabricated within a fluid reservoir located at the terminating end of a microchannel. Application of an electric field across this membrane has been shown to block a majority of the electroosmotic flow generated within the open duct yielding a high pressure at the channel–membrane junction. Experiments show the realization of higher pressure‐driven velocities in an electric field‐free separation channel integrated to the micropump with this design compared to other similar micropumps described in the literature. In addition, the noted velocity was found to be less sensitive to the extent of Debye layer overlap in the channel network, and therefore more impressive when working with background electrolytes having higher ionic strengths. With the current system, pressure‐driven velocities up to 3.6 mm/s were realized in a 300‐nm‐deep separation channel applying a maximum voltage of 3 kV at a channel terminal. To demonstrate the separative performance of our device, a nanofluidic pressure‐driven ion‐chromatographic analysis was subsequently implemented that relied on the slower migration of cationic analytes relative to the neutral and anionic ones in the separation channel likely due to their strong electrostatic interaction with the channel surface charges. A mixture of amino acids was thus separated with resolutions greater than those reported by our group for a similar analysis previously. 相似文献
9.
Robert M. Lorenz 《Analytica chimica acta》2008,630(2):124-130
This paper describes a microfluidic platform for the on-demand generation of multiple aqueous droplets, with varying chemical contents or chemical concentrations, for use in droplet based experiments. This generation technique was developed as a complement to existing techniques of continuous-flow (streaming) and discrete-droplet generation by enabling the formation of multiple discrete droplets simultaneously. Here sets of droplets with varying chemical contents can be generated without running the risk of cross-contamination due to the isolated nature of each supply inlet. The use of pressure pulses to generate droplets in parallel is described, and the effect of droplet size is examined in the context of flow rates and surfactant concentrations. To illustrate this technique, an array of different dye-containing droplets was generated, as well as a set of droplets that displayed a concentration gradient of a fluorescent dye. 相似文献
10.
This paper describes a microfluidic multi-injector (MMI) that can generate temporal and spatial concentration gradients of soluble molecules. Compared to conventional glass micropipette-based methods that generate a single gradient, the MMI exploits microfluidic integration and actuation of multiple pulsatile injectors to generate arbitrary overlapping gradients that have not previously been possible. The MMI device is fabricated in poly(dimethylsiloxane) (PDMS) using multi-layer soft lithography and consists of fluidic channels and control channels with pneumatically actuated on-chip barrier valves. Repetitive actuation of on-chip valves control pulsatile release of solution that establishes microscopic chemical gradients around the orifice. The volume of solution released per actuation cycle ranged from 30 picolitres to several hundred picolitres and increased linearly with the duration of valve opening. The shape of the measured gradient profile agreed closely with the simulated diffusion profile from a point source. Steady state gradient profiles could be attained within 10 minutes, or less with an optimized pulse sequence. Overlapping gradients from 2 injectors were generated and characterized to highlight the advantages of MMI over conventional micropipette assays. The MMI platform should be useful for a wide range of basic and applied studies on chemotaxis and axon guidance. 相似文献
11.
It is shown that the interaction of a particle with a liquid drop or a gas bubble may be quantitatively described over the whole distance regime by treating the fluid interface as a Hookean spring. An algorithm suitable for analyzing atomic force microscopy data suitable for a calculator or a spread-sheet is given and applied to data for oil drops. 相似文献
12.
Zhang X Gao X Jiang L Qin J 《Langmuir : the ACS journal of surfaces and colloids》2012,28(26):10026-10032
The nanofiber surface modified with physical or chemical gradients is very useful in a wide range of areas including tissue engineering, regenerative medicine, drug screening, and biomaterial chemistry. In this work, we presented a novel and straightforward microfluidic assisted approach to produce electrospinning nanofibers containing gradients in different compositions, nanoparticles and biomolecule concentrations. The series of gradient nanofibers were mainly produced by using a two inlet microfluidic device in combination with an electrospinning nozzle on a 3-D controllable platform, which exhibited different functions and properties. The controlled nanofibers with incorporated biomolecule gradient were used for guiding the spatial differentiation in mesenchymal stem cells (MSCs). This established approach is very simple, and flexible to operate, which might find enormous potential for biology and tissue engineering applications. 相似文献
13.
This paper presents a new biomechanical analysis method for discrimination between cancerous and normal cells through compression by poly(dimethylsiloxane) (PDMS) membrane deflection in a microfluidic device. When a cell is compressed, cellular membrane will expand and then small bulges will appear on the peripheral cell membrane beyond the allowable strain. It is well known that the amount of F-actin in cancer cells is less than that of normal cells and bulges occur at the sites where cytoskeleton becomes detached from the membrane bilayer. Accordingly, we have demonstrated the difference of the bulge generation between breast cancer cells (MCF7) and normal cells (MCF10A). After excessive deformation, the bulges generated in MCF7 cells were not evenly distributed on the cell periphery. Contrary to this, the bulges of MCF10A cells showed an even distribution. In addition, the morphologies of bulges of MCF7 and MCF10A cells looked swollen protrusion and tubular protrusion, respectively. Peripheral strains at the moment of the bulge generation were also 72% in MCF7 and 46% in MCF10A. The results show that the bulge generation can be correlated with the cytoskeleton quantity inside the cell, providing the first step of a new biomechanical approach. 相似文献
14.
C. Vézy K. Stephan T. Livache A. Roget C. Rivière J.-P. Rieu R. Ferrigno 《Electrochemistry communications》2010,12(10):1266-1269
The combination of microfluidic and electrochemistry for the generation of surface anisotropy of functionalized pyrrole is described. By using co-electropolymerization of pyrrole and pyrrole-biotin in a microfluidic environment, we have created a surface density gradient of pyrrole-biotin on gold electrodes as revealed by fluorescence. The combination of fast electropolymerization and microfluidic allows the transfer of a local volume anisotropy to a surface anisotropy with a tuneable slope of the gradient. 相似文献
15.
A simple method was developed for injecting a sample on a cross-form microfluidic chip by means of hydrostatic pressure combined with electrokinetic forces. The hydrostatic pressure was generated simply by adjusting the liquid level in different reservoirs without any additional driven equipment such as a pump. Two dispensing strategies using a floating injection and a gated injection, coupled with hydrostatic pressure loading, were tested. The fluorescence observation verified the feasibility of hydrostatic pressure loading in the separation of a mixture of fluorescein sodium salt and fluorescein isothiocyanate. This method was proved to be effective in leading cells to a separation channel for single cell analysis. 相似文献
16.
The vast majority of droplet-based microfluidic devices are made from polydimethylsiloxane (PDMS). Unfortunately PDMS is not suitable for high frequency droplet generation at high operating pressure due to its low shear modulus. In this paper, we report the fabrication and testing of microfluidic devices using thermoset polyester (TPE). The optical characteristics of the fabricated devices were assessed and substrate resistance to pressure also investigated. TPE devices bonded using an O(2) plasma treated PET substrate at 76 °C were shown to function efficiently at pressures up to 18 MPa. TPE material retains many of the attractive features of PDMS such as ease of fabrication but significantly, has superior mechanical properties. The improved resistance of TPE to high pressures enabled investigation of high frequency droplet generation as a function of a wide range of flow-rates with three different oils as continuous phase. 相似文献
17.
This report details the method for rendering hydrophilic surfaces of microchannels fabricated in polycarbonate (PC). We characterize the wetting properties and stability of the hydrophilic character of two coatings--one formed by a layer of poly(allylamine) (PAH*) and the second including an additional layer of poly(styrene-sulfonate) (PSS). This second (PC-PAH/PSS) coating yields highly hydrophilic surface that is stable against weeks of exposure to various fluids including organic oils. This coating allows for stable generation of oil-in-water emulsions of hydrocarbon, silicone and fluorinated oils without the use of surfactants and over days of continuous use. 相似文献
18.
Shin SJ Park JY Lee JY Park H Park YD Lee KB Whang CM Lee SH 《Langmuir : the ACS journal of surfaces and colloids》2007,23(17):9104-9108
In this paper, we introduce a new continuous production technique of calcium alginate fibers with a microfluidic platform similar to a spider in nature. We have used a poly(dimethylsiloxane) (PDMS) microfluidic device embedded capillary glass pipet as the apparatus for fiber generation. As a sample flow, we introduced a sodium alginate solution, and, as a sheath flow, a CaCl2 solution was introduced. The coaxial flows were generated at the intersection of both flows, and the sodium alginate was solidified to calcium alginate by diffusion of the Ca2+ ions during traveling through the outlet pipet. The diameter changes in the sample and sheath flow variations were examined, and the size of alginate fibers was well regulated by changing both flow rates. In addition, we have measured the elasticity of dried fibers. We evaluated the potential use of alginate fibers as a cell carrier by loading human fibroblasts during the "on the fly" fabrication process. From the LIVE/DEAD assay, cells survived well during the fiber fabrication process. In addition, we evaluate the capability of loading the therapeutic materials onto the alginate fibers by immobilized bovine serum albumin-fluorescein isothiocyanate in the fibers. 相似文献
19.
Multiple methods of fabrication exist for microfluidic devices, with different advantages depending on the end goal of industrial mass production or rapid prototyping for the research laboratory. Polydimethylsiloxane (PDMS) has been the mainstay for rapid prototyping in the academic microfluidics community, because of its low cost, robustness and straightforward fabrication, which are particularly advantageous in the exploratory stages of research. However, despite its many advantages and its broad use in academic laboratories, its low elastic modulus becomes a significant issue for high pressure operation as it leads to a large alteration of channel geometry. Among other consequences, such deformation makes it difficult to accurately predict the flow rates in complex microfluidic networks, change flow speed quickly for applications in stop-flow lithography, or to have predictable inertial focusing positions for cytometry applications where an accurate alignment of the optical system is critical. Recently, other polymers have been identified as complementary to PDMS, with similar fabrication procedures being characteristic of rapid prototyping but with higher rigidity and better resistance to solvents; Thermoset Polyester (TPE), Polyurethane Methacrylate (PUMA) and Norland Adhesive 81 (NOA81). In this review, we assess these different polymer alternatives to PDMS for rapid prototyping, especially in view of high pressure injections with the specific example of inertial flow conditions. These materials are compared to PDMS, for which magnitudes of deformation and dynamic characteristics are also characterized. We provide a complete and systematic analysis of these materials with side-by-side experiments conducted in our lab that also evaluate other properties, such as biocompatibility, solvent compatibility, and ease of fabrication. We emphasize that these polymer alternatives, TPE, PUMA and NOA, have some considerable strengths for rapid prototyping when bond strength, predictable operation at high pressure, or transitioning to commercialization are considered important for the application. 相似文献
20.
Mixing a small amount of magnetic beads and regents with large volume samples evenly in microcavities of a microfluidic chip is always the key step for the application of microfluidic technology in the field of magnetophoresis analysis. This article proposes a microfluidic chip for DNA extraction by magnetophoresis, which relies on bubble rising to generate turbulence and microvortices of various sizes to mix magnetic beads with samples uniformly. The construction and working principle of the microfluidic chip are introduced. CFD simulations are conducted when magnetic beads and samples are irritated by the generation of gas bubbles with the variation of supply pressures. The whole mixing process in the microfluidic chip is observed through a high-speed camera and a microfluidic system when the gas bubbles are generated continuously. The influence of supply pressure on the mixing characteristics of the microfluidic chip is investigated and discussed with both simulation and experiments. Compared with magnetic mixing, bubble mixing can avoid the magnetic beads gather phenomenon caused by magnetic forces and provide a rapid and high efficient solution to realize mixing small amount of regents in large volume samples in a certain order without complex moving structures and operations in a chip. Two applications of mixing with the proposed microfluidic chip are also carried out and discussed. 相似文献