首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 78 毫秒
1.
Centri-voltammetry is a method that combines centrifugation and voltammetry. This method, developed by our group in 2003, yielded promising results when applied to trace analysis of metal ios. We demonstrate here the first application of centri-voltammetry to biosensing systems. A xanthine biosensor was constructed by immobilizing xanthine oxidase on a planar platinum electrode which then was placed at the bottom of a centri-voltammetric cell. The experimental parameters were optimized to give two linear ranges. The first is from 0.1 to 1???M, and the second from 5 to 50???M. The RSD is 3.4 (n?=?5). The biosensor was applied to the determination of xanthine in wine and in urine. Calculated recoveries are 101?±?0.61% (n?=?3) for wine samples, and 102?±?0.556% (n?=?3) for urine samples.
Figure
Centri-voltammetry is a method, which combines the advantages of centrifugation and voltammetry. In this work, the performance of biocentri-voltammetry for xanthine detection has been investigated. After the optimization studies and examination of analytical characteristics, developed centri-voltammetric biosensor was applied for xanthine detection in wine and in urine samples.  相似文献   

2.
We report on the determination of choline and acetylcholine via biocentrivoltammetry. This method combines centrifugation and voltammetry and is based on a carbon paste electrode modified with acetylcholinesterase and choline oxidase. The electrode was placed at the bottom of a biocentrivoltammetric cell. Acetylcholine and choline are accumulated on the enzyme electrode via centrifugative forces, upon which a direct voltammetric scan is applied. Reaction time, pH values, quantities of enzyme and centrifugation parameters were optimized. A linear response is obtained in the 0.07 to 10?μM concentration range of acetylcholine, and a limit of detection as low as 0.5?μM. The linear range is between 0.1 and 500?μM for choline. The method was applied to the determination of acetylcholine and choline in spiked serum samples.
Figure
This work constitutes the first application of biocentri-voltammetry for ACh detection. Biocentri-voltammetry is the method where centrifuge and voltammetry is combined in a specially designed working cell. As a result, sensitive and effective biosensor was obtained.  相似文献   

3.
We report on a novel sensor for the electrochemical determination of thiourea (TU). It is based on an active carbon paste electrode modified with copper oxide nanoparticles. The modified electrode and the electrochemical properties of thiourea on its surface were investigated using cyclic voltammetry and differential pulse voltammetry. Under optimized conditions, the detection limit is 20 μg?L?1 of TU. The method was applied to the determination of thiourea in fruit juice, orange peel and industrial waste water.
Figure
Cyclic voltammograms of ACPE (A), CuO/ACPE (B) and CuO/CPE (C) in pH 8 phosphate buffered saline.  相似文献   

4.
Centri-voltammetry is a method for concentrating an analyte on an electrode with the aid of a centrifuge. It can be performed in the presence or the absence of a solid carrier/support. This is followed by a voltammetric (analytical) scan. Specifically, we describe here an application of the technique to the determination of glutathione (GSH). Silica gel is used as the carrier precipitate to which gold nanoparticles were added in order to improve accumulation as a result of their strong affinity for thiols. Voltammetry was performed with a carbon paste electrode modified with multi-wall carbon nanotubes. The response to GSH is linear in the 25 and 800 μM concentration range (the correlation coefficient being 0.9915) and the relative standard deviation is 3.40 % (at 250 μM of GSH and n?=?6). The procedure was successfully applied to the determination of GSH in wine and in synthetic plasma using the standard addition method. The recoveries are 100.8 % and 100.0 %, respectively.
Figure
Centri-voltammetric GSH detection was conducted where silica gel and AuNP were used as carrier materials. As a result, sensitive, robust and practical method was developed for GSH detection.  相似文献   

5.
We describe a silver(I)-selective carbon paste electrode modified with multi-walled carbon nanotubes and a silver-chelating Schiff base, and its electrochemical response to Ag(I). Effects of reduction potential and time, accumulation time, pH of the solution and the stripping medium were studied by differential pulse anodic stripping voltammetry and optimized. The findings resulted in a method for the determination of silver over a linear response range (from 0.5 to 235 ng?mL?1) and with a detection limit as low as 0.08 ng?mL?1. The sensor displays good repeatability (with the RSD of ±?2.75 % for 7 replicates) and was applied to the determination of Ag(I) in water samples and X-ray photographic films.
Figure
Open circuit accumulation of Ag(I) onto a surface of EHPO-MCPE and determination by Differential pulse anodic stripping voltammetry  相似文献   

6.
We report on an electrode for the amperometric determination of lorazepam. A glassy carbon electrode was coated with a molecular imprint made by electropolymerization of ortho-phenylenediamine and filled with multiwalled carbon nanotubes and gold nanoparticles, which enhances the transmission of electrons. The sensor was studied with respect to its response to hexacyanoferrate (III) as a probe and by electrochemical impedance spectroscopy, cyclic voltammetry and square wave voltammetry. The linear response range to Lorazepam is from 0.5 nM to 1.0 nM and from 1.0 nM to 10.0 nM, with a detection limit of 0.2 nM (at an S/N of 3). The electrode was successfully applied to determine Lorazepam in spiked human serum.
Figure 1
The preparation of schematic of the AuNP/MIP/f?MWCNT/GCE electrode  相似文献   

7.
We report on a novel tin-bismuth alloy electrode (SnBiE) for the determination of trace concentrations of zinc ions by square-wave anodic stripping voltammetry without deoxygenation. The SnBiE has the advantages of easy fabrication and low cost, and does not require a pre-treatment (in terms of modification) prior to measurements. A study on the potential window of the electrode revealed a high hydrogen overvoltage though a limited anodic range due to the oxidation of tin. The effects of pH value, accumulation potential, and accumulation time were optimized with respect to the determination of trace zinc(II) at pH 5.0. The response of the SnBiE to zinc(II) ion is linear in the 0.5–25?μM concentration range. The detection limit is 50?nM (after 60?s of accumulation). The SnBiE was applied to the determination of zinc(II) in wines and honeys, and the results were consistent with those of AAS.
Figure
A novel tin-bismuth alloy electrode was used for determination of trace Zn2+ in wines and honeys by square-wave anodic stripping voltammetry without any deoxygenating.  相似文献   

8.
A highly sensitive electrochemical sensor for determination of L-cysteine (CySH) is presented. It is based on vertically aligned multiwalled carbon nanotubes modified with Pt nanoparticles by magnetron sputtering deposition. The morphology of the nanocomposite was characterized by scanning electron microscopy, transmission electron microscopy and energy-dispersive. The electrochemistry of CySH was investigated by cyclic voltammetry, differential pulse voltammetry and chronoamperometry. The mechanism for the electrochemical reaction of CySH at the modified electrode at different pH values is discussed. The electrode exhibits a higher electrocatalytic activity towards the oxidation of CySH than comparable other electrodes. It displays a linear dependence (R 2?=?0.9980) on the concentration of CySH in the range between 1 and 500 μM and at an applied potential of +0.45 V, a remarkably low detection limit of 0.5 μM (S/N?=?3), and an outstandingly high sensitivity of 1.42?×?103 μA?mM?1?cm?2, which is the highest value ever reported. The electrode also is highly inert towards other amino acids, creatinine and urea. The sensor was applied to the determination of CySH in urine with satisfactory recovery, thus demonstrating its potential for practical applications.
Figure
Pt nanoparticles on carbon nanotubes by sputtering deposition show high performance for L-cysteine sensing  相似文献   

9.
We report on an electrochemical aptasensor for the ultrasensitive determination of thrombin. A glassy carbon electrode modified with a graphene-porphyrin nanocomposite exhibits excellent electrochemical activity and can be used as a redox probe in differential pulse voltammetry of the porphyrin on its surface. The thrombin aptamer is then immobilized via p-stacking interactions between aptamer and graphene and π-π stacking with porphyrin simultaneously. The resulting electrochemical aptasensor displays a linear response to thrombin in the 5–1,500 nM concentration range and with a limit of detection of 0.2 nM (at an S/N of 3). The sensor benefits from the synergetic effects of graphene (with its high conductivity and high surface area), of the porphyrin (possessing excellent electrochemical activity), and of the aptamer (with its high affinity and specificity). This kind of aptasensor conceivably represents a promising tool for bioanalytical applications.
Figure
The representation of the sensing procedure for analysis of thrombin based on the TA/GN-Por/GCE by an electrochemical strategy  相似文献   

10.
A sensitive amperometric sensor for hydrogen peroxide (HP) was constructed that is based on a glassy carbon electrode (GCE) modified with silver nanoparticles on poly(alizarin yellow R). The polymer was electropolymerized onto the surface of the GCE by cyclic voltammetry (CV), and the AgNPs were then electrodeposited onto its surface. The electrode was characterized by scanning electron microscopy and CV, and used for amperometric determination of HP. The electrode exhibits a favorable catalytic activity towards the reduction of HP, with a linear response range from 1.0???M to 450???M and a detection limit of 0.32???M. The sensor also displays high selectivity, excellent reproducibility, and good long-term stability.
Figure
Schematic representation of the preparation process of the HP sensor and catalytic activity towards HP  相似文献   

11.
We describe a new method for differential-pulse anodic stripping voltammetric determination of thallium(I) using a carbon paste electrode modified with dicyclohexyl-18-crown-6. The effect of supporting electrolyte (type and pH), accumulation and reduction potential, and of time and amount of modifier were investigated by differential pulse anodic stripping voltammetry. A method was then worked out for the determination of thallium at low levels. Under optimized conditions, the response to Tl(I) is linear in the range from 3.0 to 250 ng mL?1. The detection limit is 0.86 ng mL?1. The sensor displays good repeatability (with a relative standard deviation of ±2.70 % for n?=?7) and was applied to the determination of Tl(I) in water, hair samples, and certified reference materials.
Figure
Crown ethers allow only some ions to entry and complex formation that their sizes equal to ether cavity.  相似文献   

12.
A hydrothermal technique was used to synthesize nickel ferrite nanoparticles (NF-NPs) deposited on multi-walled carbon nanotubes (MWCNTs). The material was characterized by scanning electron microscopy, energy dispersive spectrometry, and X-ray powder diffraction which showed that the NF-NPs are located on the surface of the carboxylated MWCNTs. The material was used to modify a glassy carbon electrode which then was characterized via cyclic voltammetry, electrochemical impedance spectroscopy, and amperometry. The electrode displays strong electrochemical response to hydrazine. A potential hydrazine sensing scheme is suggested.
Figure
A fast and sensitive hydrazine electrochemical sensor has been fabricated by dipping nickel ferrite/multi-walled carbon nanotubes onto the pretreated glassy carbon electrode. The sensor had excellent stability, rapid response, ease of construction and utilization for hydrazine determination.  相似文献   

13.
We report on the voltammetric determination of the flavonoid Baicalein by using a carbon paste electrode that was doped with multi-walled carbon nanotubes. The resulting sensor exhibits excellent redox activity towards Baicalein due to the large surface area and good conductivity of the electrode. Cyclic voltammetry at various scan rates was used to investigate the redox properties of Baicalein. At the optimum conditions, the sensor displays a linear current response to Baicalein in the 0.02–10 μM concentration range, with a limit of detection of 4.2 n M. The method was successfully applied to the determination of Baicalein in spiked human blood serum samples and in a Chinese oral liquid.
Figure
We construct a new voltammetric sensor, based on multi-walled carbon nanotubes (MWCNT) doped Carbon paste electrode(CPE), The proposed electrode can improve the oxidation of Baicalein intensively, which can applied to the quantitative determination of Baicalein with wide linear response and low detection limit.  相似文献   

14.
We describe the fabrication of a sensitive label-free electrochemical biosensor for the determination of sequence-specific target DNA. It is based on a glassy carbon electrode (GCE) modified with graphene, gold nanoparticles (Au-NPs), and polythionine (pThion). Thionine was firstly electropolymerized on the surface of the GCE that was modified with graphene by cyclic voltammetry. The Au-NPs were subsequently deposited on the surface of the pThion/graphene composite film by adsorption. Scanning electron microscopy and electrochemical methods were used to investigate the assembly process. Differential pulse voltammetry was employed to monitor the hybridization of DNA by measuring the changes in the peak current of pThion. Under optimal conditions, the decline of the peak current is linearly related to the logarithm of the concentration of the target DNA in the range from 0.1 pM to 10 nM, with a detection limit of 35 fM (at an S/N of 3). The biosensor exhibits good selectivity, acceptable stability and reproducibility.
Figure
A label-free DNA biosensor based on Au-NPs/pThion/graphene modified electrode has been fabricated. Differential pulse voltammetry (DPV) was employed to monitor DNA hybridization event by measurement of the peak current changes of pThion.  相似文献   

15.
We report on a carbon ionic liquid electrode modified with a composite made from Nafion, graphene oxide and ionic liquid, and its application to the sensitive determination of rutin. The modified electrode was characterized by cyclic voltammetry and electrochemical impedance spectroscopy. It shows excellent cyclic voltammetric and differential pulse voltammetric performance due to the presence of nanoscale graphene oxide and the ionic liquid, and their interaction. A pair of well-defined redox peaks of rutin appears at pH 3.0, and the reduction peak current is linearly related to its concentration in the range from 0.08 μM to 0.1 mM with a detection limit of 0.016 μM (at 3σ). The modified electrode displays excellent selectivity and good stability, and was successfully applied to the determination of rutin in tablets with good recovery.
Figure
A Nafion, graphene oxide and ionic liquid 1-ethyl-3-methylimidazolium tetrafluoroborate composite was modified on carbon ionic liquid electrode (CILE) for the sensitive detection of rutin.  相似文献   

16.
We have constructed a carbon nitride electrode modified with a bismuth film and show that it can be used for the electroanalysis of lead(II) by differential pulse anodic stripping voltammetry. The combination of such materials is shown to greatly improve the sensing capability of the electrode. Under the optimal conditions, the electrochemical response of the modified electrode is linearly related to the concentration of Pb(II) in the 6 – 1,000 nM concentration range (R = 0.9983). The detection limit is 2.0 pM (at an SNR of 3), and the sensitivity is 8 times better of that of respective graphite electrodes. The sensor enables rapid, highly sensitive, continuous, and environmentally friendly determination of trace levels of Pb(II) at affordable costs.
Figure
Graphite-like carbon nitride (g-C3N4) as a new electrode material shows high performance for the determination of Pb(II).  相似文献   

17.
We describe a biosensor for phenolic compounds that is based on a glassy carbon electrode modified with tyrosinase immobilized on multiwalled carbon nanotubes (MWNTs). The MWNTs possess excellent inherent electrical conductivity which enhances the electron transfer rate and results in good electrochemical catalytic activity towards the reduction of benzoquinone produced by enzymatic reaction. The biosensor was characterized by cyclic voltammetry, and the experimental conditions were optimized. The cathodíc current is linearly related to the concentration of the phenols between 0.4???M and 10???M, and the detection limit is 0.2???M. The method was applied to the determination of phenol in water samples.
Figure
A tyrosinase and carbon nanotubes (MWNTs) modified glassy carbon electrode was fabricated and used for the sensitive detection of phenol. The reduction peak of benzoquinone produced by enzymatic reaction of phenol was greatly enhanced due to the presence of MWNTs(c)  相似文献   

18.
We introduce a novel voltammetric method, so-called sinusoidal envelope voltammetry, for use in electronic tongues. Fourier transformation was used to transform the data of the signal from the time domain to the frequency domain. The four taste substances, acesulfame potassium, monosodium glutamate, potassium chloride and tartaric acid, are shown to exhibit abundant frequency characteristics in the power spectrum of a Fourier transformation. This indicates that the power spectrum from sinusoidal envelope voltammetry can be used as fingerprints of samples for classification. Principal component analysis along with discrimination index and multi-frequency large amplitude pulse voltammetry as a reference technique is used to evaluate the separation ability of sinusoidal envelope voltammetry. The score plots of the method for the four taste substances and for the five brands of Jiafan rice wine show better discrimination ability than multi-frequency large amplitude pulse voltammetry. Sinusoidal envelope voltammetry is considered to be a promising technique for use in voltammetric electronic tongues.
Figure
The sketch of the electronic tongue with sinusoidal envelope voltammetry (SEV) and multi‐frequency large amplitude pulse voltammetry (MLAPV)  相似文献   

19.
We report on a method for electrochemical enantioselective recognition of tryptophan (Trp) enantiomers. It is based on competitive host-guest interaction between a deoxy-(2-aminoethylamino)-β-cyclodextrin (CD) bound to graphene nanosheets and the Cu(II) complexes of the Trp enantiomers via a ligand exchange mechanism. Chiral recognition was investigated via cyclic voltammetry and electrochemical impedance spectroscopy. The results reveal that the CD bound to graphene displays a stronger interaction with the Cu(II) complex of L-Trp than to that of D-Trp. The method was applied to the determination of the ratio of Trp enantiomers in mixtures.
Figure
The CD-GNs are dipped in D-Trp or L-Trp solution containing Cu(II), the complexes of metal ion with L-Trp caused more remarkable difference in the [Fe(CN)6]3?/4? than the complexes of metal ion with D-Trp.  相似文献   

20.
Liquid phase microextraction (LPME) is a popular technique for sample pretreatment before the trace determination of target compounds from complex matrices, examples being pesticides in environmental and food samples, or drug residuals in biological samples such as blood or urine. LPME is simple, affordable, easy to operate, and highly sensitive. It is a miniaturized implementation of conventional liquid-liquid extraction in which only a few microliters of solvents are used instead of several hundreds of milliliters. This review focuses on newly developed LPME-based techniques, their application to environmental and biological samples, on their limitations, and on future applications.
Figure
Liquid phase microextraction (LPME) is a popular technique for sample pretreatment before the trace determination of target compounds from complex matrices. This review focuses on newly developed LPME-based techniques, their application to environmental and biological samples, on their limitations, and on future applications.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号