首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 21 毫秒
1.
This work describes the development, optimization, and validation of a new method for the simultaneous determination of a wide range of pharmaceuticals (beta-blockers, lipid regulators…) and personal care products (fragrances, UV filters, phthalates…) in both aqueous and solid environmental matrices. Target compounds were extracted from sediments using pressurized hot water extraction followed by stir bar sorptive extraction. The first stage was performed at 1,500 psi during three static extraction cycles of 5 min each after optimizing the extraction temperature (50–150 °C) and addition of organic modifiers (% methanol) to water, the extraction solvent. Next, aqueous extracts and water samples were processed using polydimethylsiloxane bars. Several parameters were optimized for this technique, including extraction and desorption time, ionic strength, presence of organic modifiers, and pH. Finally, analytes were extracted from the bars by ultrasonic irradiation using a reduced amount of solvent (0.2 mL) prior to derivatization and gas chromatography–mass spectrometry analysis. The optimized protocol uses minimal amounts of organic solvents (<10 mL/sample) and time (≈8 h/sample) compared to previous existing methodologies. Low standard deviation (usually below 10 %) and limits of detection (sub-ppb) vouch for the applicability of the methodology for the analysis of target compounds at trace levels. Once developed, the method was applied to determine concentrations of these compounds in several types of sample (wastewater, seawater, pore water, and sediment) from Cadiz Bay (SW Spain). To our knowledge, these findings represent the first information available on the presence of some of the target compounds in the marine environment.  相似文献   

2.
The congener profile of samples contaminated with dioxin and dioxin-like compounds allows identifying sources of contamination. This article studies the statistical methods of congener profile analysis reported in the literature with respect to the reliability of obtained results. The performance of customary analysis methods regarding raw data transformation and applied TEF (toxic equivalency factor) values is discussed. In particular, the method of principal component analysis and k-means cluster is taken as an example and examined in detail. Reasons for occurring inconsistencies such as the dependence of results on raw data transformation and the disregard of measurement uncertainty are described, and it is shown that they also explain inconsistencies in other methods of cluster analysis such as hierarchical cluster analysis and neural networks. It is concluded that these methods cannot be employed to reach court-proof decisions, i.e. decisions which meet court evidentiary standards. An alternative approach to analyzing congener profiles based on mathematical statistics is briefly presented, allowing reliable, court-proof decisions.  相似文献   

3.
A Quick, Easy, Cheap, Effective, Rugged and Safe (QuEChERS) method has been adapted and validated for the simultaneous determination of priority (16 PAHs, 12 PCBs and 7 organochlorine pesticides (OCPs)) and emerging (carbamazepine, 9 musks and 6 sunscreens) pollutants in sediments by Gas Chromatography-Mass Spectrometry (GC-MS). The sample preparation was adapted by modifying the nature of the extraction solvent and optimising clean-up and evaporation steps. The method was validated by the analysis of spiked estuarine and marine sediments. Analytical performances were evaluated in terms of linearity, accuracy, precision and detection limits. The method shows good linearity (coefficients of determination > 0.998) and repeatability (RSD < 10%). Obtained recoveries are acceptable, ranging from 62% to 131% for all the compounds. Detection limits are estimated to range from 0.01 ng/g to 3.18 ng/g. This developed method offers the ability to detect and quantify several priority and emerging pollutants at low concentration levels in sediments.  相似文献   

4.
High-valent metal-oxo complexes catalyze C-H bond activation by oxygen insertion, with an efficiency that depends on the identity of the transition metal and its oxidation state. Our study uses density functional calculations and theoretical analysis to derive fundamental factors of catalytic activity, by comparison of a ruthenium-oxo catalyst with its iron-oxo analogue toward methane hydroxylation. The study focuses on the ruthenium analogue of the active species of the enzyme cytochrome P450, which is known to be among the most potent catalysts for C-H activation. The computed reaction pathways reveal one high-spin (HS) and two low-spin (LS) mechanisms, all nascent from the low-lying states of the ruthenium-oxo catalyst (Ogliaro, F.; de Visser, S. P.; Groves, J. T.; Shaik, S. Angew. Chem. Int. Ed. 2001, 40, 2874-2878). These mechanisms involve a bond activation phase, in which the transition states (TS's) appear as hydrogen abstraction species, followed by a C-O bond making phase, through a rebound of the methyl radical on the metal-hydroxo complex. However, while the HS mechanism has a significant rebound barrier, and hence a long lifetime of the radical intermediate, by contrast, the LS ones are effectively concerted with small barriers to rebound, if at all. Unlike the iron catalyst, the hydroxylation reaction for the ruthenium analogue is expected to follow largely a single-state reactivity on the LS surface, due to a very large rebound barrier of the HS process and to the more efficient spin crossover expected for ruthenium. As such, ruthenium-oxo catalysts (Groves, J. T.; Shalyaev, K.; Lee, J. In The Porphyrin Handbook; Biochemistry and Binding: Activation of Small Molecules, Vol. 4; Kadish, K. M., Smith, K. M., Guilard, R., Eds.; Academic Press: New York, 2000; pp 17-40) are expected to lead to more stereoselective hydroxylations compared with the corresponding iron-oxo reactions. It is reasoned that the ruthenium-oxo catalyst should have larger turnover numbers compared with the iron-oxo analogue, due to lesser production of suicidal side products that destroy the catalyst (Ortiz de Montellano, P. R.; Beilan, H. S.; Kunze, K. L.; Mico, B. A. J. Biol. Chem. 1981, 256, 4395-4399). The computations reveal also that the ruthenium complex is more electrophilic than its iron analogue, having lower hydrogen abstraction barriers. These reactivity features of the ruthenium-oxo system are analyzed and shown to originate from a key fundamental factor, namely, the strong 4d(Ru)-2p(O,N) overlaps, which produce high-lying pi(Ru-O), sigma(Ru-O), and sigma(Ru-N) orbitals and thereby to lead to a preference of ruthenium for higher-valent oxidation states with higher electrophilicity, for the effectively concerted LS hydroxylation mechanism, and for less suicidal complexes. As such, the ruthenium-oxo species is predicted to be a more robust catalyst than its iron-oxo analogue.  相似文献   

5.
A multifunctional integrated microfluidic biochip device was engineered to estimate the activity-toxicity and composition principle of medicine in a cell model in vitro.  相似文献   

6.
Fast industrialization, increasing population, rapid urbanization, and the greediness of creamy layer in the society without the issues of caring the sustainability of ecosystem are the main out of many reasons behind the environmental catastrophe. The ecological balance is disturbed with the noxious materials generated from the uncontrolled use of modern science and technology and also unscientific and unsystematic societal growths. To save the modern civilization, a fast-track task is the monitoring of the toxic materials for the maintenance of sustainable ecological health and their utilization in a circular economy. Accordingly, optical methods are employed for the detection and estimation of environmental contaminants for immediate monitoring. The stability and structural tunability of the coordination polymeric (CPs) materials make them promising optical sensors for easy, low cost, reliable, selective, and sensitive detection of toxic ions/molecules. The crystallinity, thermal, mechanical, magnetic, and optical stability and flexibility of the CPs play a beneficial role for the accurate and stress-free recognition of the toxicants. In this review, the recent developments as well as the outlook on the sensing of pollutants at a very low concentration level using CPs as selective and specific sensors by spectro-fluorometric method are summarized. The progresses and challenges in the fabrication of hybrid materials and understanding their structure property correlations are described with an aim to motivate and facilitate the future researchers to perform research in the area.  相似文献   

7.
Theprotectionofhydroxybyformationoftetrahydropyranyl(THP)ethersisofgreatimportanceinorganicsynhesisparticularlyduringthesynthesisofnaturalproducts.'OwingtotheremarkablestabilityofTHPethersunderavarietyofreactionconditions,suchasneutralandstronglybasicmedia,reactionsinvolvingGrignardreagents,reductionwithhydrides,oxidation,oxidativealkylationandacylation,etc.,tetrahydropyranylationisoneofthemethodsofchoicetoprotectahydroxylgroupsinamultisteporganicsynthesis.'Generallytetrahydropyranylationofa…  相似文献   

8.
A new easy method has been presented to calculate the variable intervals corresponding to the stable univariant curves and to discriminate the stabilities of invariant points. This method and the one reported previously constitute a simple and universal theory for the computer-plotting of the equilibrium phase diagrams of a multisystem—sign function matrix (SFM) discrimination method. Its main steps are: determining the stable univariant scheme according to the derivative (or difference) of AIG m ; grouping the univariant curves by comparisons of the mutual relations among them; determining the existing intervals of the variables for the stable curves by comparisons of coordinate values of the curves about the invariant point; determining the stabilities of invariant points by comparisons of relations between the common curves and the invariant points. This method is suitable for any kind of phase diagram of closed or open systems in a phase diagram “space” with either 2 or more than 2 dimensions.  相似文献   

9.
Oxygenradicalsaswellas0theroxygen-derivedspeciesincludinglipidperoxides,havebeensuggestCdaspotentiallyimportantcausativeagents0fagingandvarioushumandi,...,i-3suchascancer,multiplescler0sis,Parkinson'sdisease,autoinununediseases,ischemia,anemia,seniledementiaandasbestosis.Am0ngthevari0usradicals,thehydroxylradical(OH)ispresumedtoplayacentralroleduetoitSstr0ngactivity'.TheimPortanceofremovingexcessiveactiveoxygenspeciesfromlivingorganismsisbecondngincreasinglyrec0gnized,t0getherwithagrowingint…  相似文献   

10.
The wavelength for the peak of fluorescence emission of thioflavin T(ThT) was changed from 445 nm to 481 nm when ThT was added in Aβ solution which indicating theβ-sheet structure of Aβ fibril.The significant decrease in the intensity of fluorescence at 481 nm was observed when the baicalein was added in mixed solution of Aβ and ThT,suggesting that the depolymerization of Aβ fibrils happened and there were Aβfibrils left to react with ThT to keep the initial fluorescence intensity.And the existing Aβfibrils are disaggregated by baicalein in a time- and dose-dependent manner.AFM images of the morphologies of the Aβ1-42 fibrils obviously changed smaller and more dispersive when baicalein added indicating also the depolymerization of Aβ.The results demonstrate a basis for development of a potential herb drug candidate for the treatment of Alzheimer’s disease(AD).  相似文献   

11.
A new doping control screening method for the analysis of diuretics and stimulants using ultra high pressure liquid chromatography–high resolution Orbitrap mass spectrometry has been developed. The screening was performed in full scan MS with scan-to-scan polarity switching which allowed to detect more than 120 target analytes. Sample preparation was limited to 10-fold dilution of the urine into the internal standard solution followed by injection. Total run time per sample was 10 min. Validation of the method yielded detection limits for diuretics between 25 and 250 ng mL−1 and for stimulants between 5 and 500 ng mL−1. The screening method has been implemented in routine doping control.  相似文献   

12.
A high-throughput screening method for the exploration of optimal curing parameters and resistance to solvents of NANOMER® coating materials based on the temperature-dependent swellability was developed. The screening method was first tested using a model sol made of pre-hydrolyzed (3-glycidoxypropyl)triethoxysilane (GPTES), tetraethoxysilane (TEOS), (heptadecafluoro-1,1,2,2-tetrahydrodecyl)triethoxysilane (FTS) and zirconium complex (prepared of zirconium-tert-butoxide complexed with acetylacetonate) charged with reactive diluent trimethylolpropan-triglycidether and defined amounts of fluorescein and cured at different temperatures. Afterwards, fluorescein was extracted with sodium hydroxide solution and the optical density of the supernatant of all samples was measured at 490 nm which is sensitive to the dye concentration. The optical density (OD) correlates with the degree of curing. According to this screening a temperature $CDATA \geq 140 ^\circA high-throughput screening method for the exploration of optimal curing parameters and resistance to solvents of NANOMER? coating materials based on the temperature-dependent swellability was developed. The screening method was first tested using a model sol made of pre-hydrolyzed (3-glycidoxypropyl)triethoxysilane (GPTES), tetraethoxysilane (TEOS), (heptadecafluoro-1,1,2,2-tetrahydrodecyl)triethoxysilane (FTS) and zirconium complex (prepared of zirconium-tert-butoxide complexed with acetylacetonate) charged with reactive diluent trimethylolpropan-triglycidether and defined amounts of fluorescein and cured at different temperatures. Afterwards, fluorescein was extracted with sodium hydroxide solution and the optical density of the supernatant of all samples was measured at 490 nm which is sensitive to the dye concentration. The optical density (OD) correlates with the degree of curing. According to this screening a temperature C is necessary for proper curing. The time dependence of extraction reveals information on resistance against sodium hydroxide solution, i. e. alkali resistance. The time dependent extraction of fluorescein at C of coatings cured at 100 and 140°C, respectively, shows a better resistance against 0.1 M sodium hydroxide solution for the one cured at 140°C, especially in the time range 10–60 min. The whole process — sol preparation, mixing of sols with dye, extraction, and optical spectroscopy—can be performed automatically. Further testes were made to proof the usability of this process. 96 hybrid materials were screened in regard to their alkali resistance and finally, a total number of 14 clear organic-inorganic hybrid coating systems with improved stability against sodium hydroxide solution were derived from this study.  相似文献   

13.
A new multiresidue method for the determination of 13 emerging and priority pollutants in lettuce, including pesticides, pharmaceuticals, personal care products, polycyclic aromatic hydrocarbons (PAHs), and phenolic estrogens, has been developed using matrix solid-phase dispersion combined to pressurized fluid extraction (PFE) followed by gas chromatography coupled to mass spectrometry determination. A sequential optimization strategy based on solvent optimization first, followed by experimental design, was performed in order to maximize target analyte extraction with the aid of response surface methodology. Firstly, a full factorial design was applied to choose the significant variables in PFE; extraction time and temperature were found to have the biggest overall effect on response for most of analytes. They were later optimized performing a central composite design and the variable response of these factors was modeled for all analytes. It was found that marked differences in physicochemical nature exerted a strong influence on extraction conditions and yield. Therefore, the effect of parameters on the response was rather different for some compounds. To overcome this conflicting behavior, a multiple response simultaneous optimization was applied using the desirability function to achieve global optimal operating conditions. The optimal conditions were attained at 13.5 min (two extraction cycles) and 104 °C in the PFE by using hexane acetone mixture (1:1). Limit of detection and limit of quantitation values were found to be between 6.6 and 58 and 7.6 and 61.7 μg kg−1, respectively.  相似文献   

14.
A new easy method has been presented to calculate the variable intervals corresponding to the stable univariant curves and to discriminate the stabilities of invariant points. This method and the one reported previously constitute a simple and universal theory for the computer-plotting of the equilibrium phase diagrams of a multisystem——sign function matrix (SFM) discrimination method. Its main steps are: determining the stable univariant scheme according to the derivative (or difference) of △rGm; grouping the univariant curves by comparisons of the mutual relations among them; determining the existing intervals of the variables for the stable curves by comparisons of coordinate values of the curves about the invariant point; determining the stabilities of invariant points by comparisons of relations between the common curves and the invariant points. This method is suitable for any kind of phase diagram of closed or open systems in a phase diagram "space" with either 2 or more than 2 dimensions.  相似文献   

15.
The analysis of persistent organic pollutants is a real challenge due to the large number of compounds with varying chemical and physical properties. Gas chromatography with electron capture detection or mass spectrometry has been the method of choice for the past 50 years. Comprehensive two-dimensional gas chromatography (GCxGC) coupled with micro-electron capture detector (μECD) is a new method that can analyze polychlorinated biphenyls (PCBs), organochlorine pesticides (OCs) and chlorobenzenes (CBz) in a single analytical run with enhanced selectivity and sensitivity over single column methods and can also be used to screen for other halogenated organics in environmental samples. An accredited routine method using commercially available LECO GCxGC-μECD and a column combination DB-1 × Rtx-PCB has been developed to analyse PCBs/OCs/CBz in soils, sediments and sludges. The method provides quantification of Aroclors and Aroclor mixtures to within 15% of target values and sub-nanogrammes per gramme detection limits.  相似文献   

16.
The extensive use of bisphenol A (BPA) in the manufacture of consumer products results in widespread human exposure to the chemical. In the body, BPA undergoes first-pass metabolism to form BPA glucuronide, considered to be a major BPA byproduct. Concentrations of total (free plus conjugated) urinary species of BPA are used to assess human exposure to BPA. However, because BPA can be present in numerous consumer and household products, potential contamination with parent BPA during collection and handling may pose a challenge when measuring BPA in such biological samples as blood or urine. In this study we investigated the in-vitro phase I metabolism of BPA in rat and human liver microsomes by using on-line solid-phase extraction–high-performance liquid chromatography–tandem mass spectrometry to identify phase I metabolites (e.g., BPA oxidation products) that could be used as potential alternative biomarkers of BPA exposure. We unambiguously identified 5-hydroxy BPA (BPA catechol) as an in-vitro oxidative metabolite of BPA, but human microsomes oxidized only about 10% of BPA to BPA catechol. We evaluated the usefulness of BPA catechol as a potential biomarker of human exposure to BPA by measuring total concentrations of BPA catechol and BPA in 20 urine samples. We detected BPA catechol at much lower concentrations and frequency than those of BPA. Furthermore, we found that free BPA catechol was rather unstable in urine, which highlights the importance of sampling techniques to adequate interpretation of biomonitoring data. Together, these findings suggest that BPA catechol may not be a suitable biomarker of environmental exposure to BPA, but could be used to confirm BPA exposure in special populations or in situations when urine specimens were potentially contaminated with BPA.  相似文献   

17.
18.
Tests and/or test items can sometimes be expensive, unique, or only performed in a few laboratories. There can be cases where assigned values are unknown, there is no information, or only poor information on the probability density function attributed to the test result. Sometimes there are neither reference materials nor the ability to establish consensus values due to a lack of experts. It can be impossible to repeat a test on the same item because it is destroyed during the test itself, or the homogeneity of tested items is unknown and no criteria can be established. Specified technical requirements concerning proficiency testing and interlaboratory comparison schemes are generally not applicable in this situation. However, interlaboratory comparison could allow laboratories to have more confidence in their results. The present paper discusses three statistical methods of assessing interlaboratory comparison results obtained in such conditions. Two methods are based on an assigned value determined from participant results through robust analysis. The third is based on the compatibility of results assessed using the ζ parameter. This paper focuses on an interlaboratory comparison for two laboratories, each testing three samples. The use of statistical methods turns out to be high risk, particularly in terms of falsely accepting results. Additionally, is shown that methods dedicated to small samples are also not efficient in detecting discrepancies of test results.  相似文献   

19.
《Tetrahedron letters》2014,55(50):6911-6914
An efficient synthesis of Ni-didecarboxysirohydrochlorin hexamethylester rac-13 was achieved by Barton olefination starting from a readily available dioxo-isobacteriochlorin rac-9. The synthetic route should open a general facile access to this type of naturally occurring hydroporphyrins. Isobacteriochlorins 36 are key intermediates in heme d1 and heme biosynthesis of sulfate reducing and denitrifying bacteria as well as in archaebacteria.  相似文献   

20.
A novel automated liquid/liquid extraction system was developed for the determination of trace contaminants in unalloyed, alloyed and highly alloyed steels and super alloys. In the presented batch extraction system the aqueous phase and the non-water miscible organic phase were brought into close phase contact by high-speed stirring with a magnetic stir bar. Iodide complexes of Ag, Bi, Cd, Pb, Sb, Sn, Tl, and Zn were extracted from aqueous steel digests into 4-methylpentan-2-one (MIBK) containing 20 g L−1 trioctylphosphine oxide. Ag, Bi, Cd, Pb, and Tl were extracted quantitatively whereas the extraction yields of Sb, Sn, and Zn were 83%, 61% and 75% respectively. Using high resolution continuum source flame AAS (HR-CS-FAAS) for analyte quantification the method was validated using 21 certified steel reference materials (CRMs).  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号