首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 319 毫秒
1.
A procedure for separation and preconcentration of trace amounts of copper in natural water samples, has been proposed. It is based on the adsorption of copper(II) ions onto a column of Amberlite XAD-2 resin loaded with calmagite reagent. This way amounts of copper within the range from 0.0125 to 25.0 μg, in a sample volume of 25 to 250 ml, and pH from 3.7 to 10.0 was concentrated as calmagite complex in a column of 0.50 g of Amberlite XAD-2 resin. Copper (II) ion was desorpted by using 5.0 ml of 2 mol l−1 hydrochloric acid. Detection and determination limits of the proposed procedure for 250 ml sample volume were 0.15 and 0.50 μg l−1, respectively. Selectivity test showed that (in the indicated concentration), calcium(II) (500 mg l−1), magnesium(II) (500 mg l−1), strontium(II) (50 mg l−1), iron(III) (10 mg l−1), nickel(II) (10 mg l−1), cobalt(II) (10 mg l−1), cadmium(II) (10 mg l−1) and lead(II) (10 mg l−1) did not interfere in copper determination by this procedure. Precision of the method, evaluated as the relative standard deviation by analyzing a series of seven replicates, was 2.42% for a copper mass of 1.0 μg in a sample volume of 100 ml. The accuracy of the proposed procedure was evaluated by means of copper determination in reference biological samples. The achieved results were in good agreement with certified values. The extractor system had a sorption capacity of 1.59 μmol of copper per gram of resin loaded with calmagite. The proposed procedure was applied for copper determination by FAAS in natural water samples. Samples were collected from different places of Salvador city, Bahia, Brazil. The achieved recovery, measured by the standard addition technique, showed that the proposed procedure had good accuracy. A good enrichment factor (50×) and simplicity are the main advantages in this analytical procedure.  相似文献   

2.
Castro MT  Baccan N 《Talanta》2005,65(5):1264-1269
In the present paper, a procedure for preconcentration and determination of copper in soft drink using flame atomic absorption spectrometry (FAAS) is proposed, which is based on solid-phase extraction of copper(II) ions as its ion pair of 1,10-phenanthroline complexes with the anionic surfactant sodium dodecil sulphate (SDS), by Amberlite XAD-2 resin. The optimization process was carried out using 24–1 factorial and 22 factorial with a center point designs. Four variables (XAD-2 mass, copper mass, sample flow rate and elution flow rate) were regarded as factors in the optimization. Student's t-test on the results of the 24–1 factorial design with eight runs for copper extraction, demonstrated that the factors XAD-2 mass and sample flow rate in the levels studied are statistically significant. The 22 factorial with a center point design was applied in order to determine the optimum conditions for extraction. The procedure proposed allowed the determination of copper with detection limits (3/S) of 3.9 μg l−1. The precision, calculated as relative standard deviation (R.S.D.) was 1.8% for 20.0 μg l−1 of copper. The preconcentration factor was 100. The robustness of this procedure is demonstrated by the recovery achieved for determination of copper in the presence of several cations. This procedure was applied to the determination of copper in soft drink samples collected in Campinas, SP, Brazil.  相似文献   

3.
Kumar M  Rathore DP  Singh AK 《Talanta》2000,51(6):1187-1196
A stable chelating resin matrix was synthesized by covalently linking o-aminophenol (o-AP) with the benzene ring of the polystyrene–divinylbenzene resin, Amberlite XAD-2, through a –N=N– group. Elemental analyses, thermogravimetric analysis (TGA) and infrared spectra have characterized the resulting chelating resin. It has been used to preconcentrate Cu2+, Cd2+, Co2+, Ni2+, Zn2+ and Pb2+, prior to their determination by flame atomic absorption spectrometry. The optimum pH values for quantitative sorption of Cu, Cd, Co, Ni, Zn and Pb are 6.2–7.4, 5.6–7.2, 5.6–9.0, 6.0–9.0, 5.7–7.0 and 5.0–6.0, respectively. These metals are desorbed (recovery 91–98%) with 4 mol dm−3 HNO3. The sorption capacity of the resin is 3.37, 3.42, 3.29, 3.24, 2.94 and 3.32 mg of metal g−1 of resin, respectively, for Cu, Cd, Co, Ni, Zn and Pb. The effect of NaF, NaCl, NaNO3, Na2SO4, and Na3PO4 on the sorption of these metal ions has been investigated. These electrolytes are tolerable up to 0.01 mol dm−3 in case of all the metal ions, except Cl which is tolerable even up to 0.1 mol dm−3 for Zn and 1.0 mol dm−3 for Pb. The preconcentration factor for Cu, Cd, Co, Ni, Zn and Pb are 50, 50, 100, 65, 40 and 40 (concentration level 10–25 μg dm−3) respectively. Simultaneous enrichment of the six metals is possible. The method has been applied to determine Cu, Cd, Co, Ni, Zn and Pb content in well water samples (RSD≤8%).  相似文献   

4.
Amberlite XAD-2 has been functionalized by coupling it, through the ---N=N--- group, with Pyrocatechol Violet (PV), and the resulting resin has been characterized by elemental analysis, thermogravimetric analysis (TGA) and IR spectra. The resin has been used for preconcentrating Zn(II), Cd(II), Pb(II) and Ni(II) ions prior to their determination by flame atomic absorption spectrometry. The optimum pH values for quantitative sorption are 5, 5–7, 4, and 3 for Zn, Cd, Pb and Ni, respectively. The four metals can be desorbed (recovery ˜98%) with 4 M HNO3; also, 4 M HCl is equally suitable except for Zn. The sorption capacity of the resin is 1410, 1270, 620 and 1360 μg g−1 resin for Zn, Cd, Ni and Pb, respectively. The effect of F, Cl, NO3, SO42− and PO43− on the sorption of these four metal ions has been investigated. They are tolerable in the range 0.01–0.20 M, for Pb. In the sorption of Zn(II) and Ni(II), the tolerance limits of all these ions are upto 0.01 M, whereas for Cd(II), F, NO3, and PO43− have been found to be tolerable upto 0.50, 0.10 and 0.10 M, respectively. The preconcentration factors are 60, 50, 23 and 18 for Zn, Cd, Pb and Ni, respectively. Simultaneous collection and determination of the four metals are possible. Cations commonly present in drinking water do not affect the sorption of either metal ion if present at a concentration level similar to that of water. The method has been applied to determine Zn, Ni and Pb content of well-water samples (RSD ≤9%).  相似文献   

5.
Praveen RS  Metilda P  Daniel S  Rao TP 《Talanta》2005,67(5):960-967
A new chelating polymeric sorbent has been developed using Merrifield chloromethylated resin anchored with quinoline-8-ol (HQ). The modified polymeric resin was characterized by FT-IR spectroscopy and elemental analysis. The HQ anchored resin showed superior binding affinity for U(VI) over Th(IV) and La(III). The influence of various physicochemical parameters on the recovery of U(VI) were optimized by both static and dynamic methods. The phase exchange kinetic studies performed for U(VI) revealed that <5 min was sufficient for reaching equilibrium metal ion sorption. The maximum sorption capacity of HQ anchored resin for U(VI) was found to be 120.30 mg g−1 of resin which is higher than other solid phase extraction sorbents reported so far excepting N,N-dibutyl, N′-benzoyl thiourea sorbed Amberlite XAD-16. The developed HQ anchored polymeric resin is highly selective as none of the extraneous species were found to have any deleterious effect. Solid phase extraction (SPE) studies performed using HQ anchored polymeric resin offered enrichment factor of 100 and the lowest concentration below which recoveries become non-quantitative is 5 μg l−1. The accuracy of the developed SPE method in conjunction with Arsenazo III procedure was tested by analyzing marine sediment (MESS-3) and soil (IAEA–Soil 7) reference materials. Furthermore, the above procedure has been successfully employed for the analysis of real soil and sediment samples.  相似文献   

6.
Prabhakaran D  Subramanian MS 《Talanta》2003,59(6):1227-1236
A new chelating polymeric sorbent was developed by functionalizing Amberlite XAD-16 with 1,3-dimethyl-3-aminopropan-1-ol via a simple condensation mechanism. The newly developed chelating matrix offered a high resin capacity and faster sorption kinetics for the metal ions such as Mn(II), Pb(II), Ni(II), Co(II), Cu(II), Cd(II) and Zn(II). Various physio-chemical parameters like pH-effect, kinetics, eluant volume and flow rate, sample breakthrough volume, matrix interference effect on the metal ion sorption have been studied. The optimum pH range for the sorption of the above mentioned metal ions were 6.0–7.5, 6.0–7.0, 8.0–8.5, 7.0–7.5, 6.5–7.5, 7.5–8.5 and 6.5–7.0, respectively. The resin capacities for Mn(II), Pb(II), Ni(II), Co(II), Cu(II), Cd(II) and Zn(II) were found to be 0.62, 0.23, 0.55, 0.27, 0.46, 0.21 and 0.25 mmol g−1 of the resin, respectively. The lower limit of detection was 10 ng ml−1 for Cd(II), 40 ng ml−1 for Mn(II) and Zn(II), 32 ng ml−1 for Ni(II), 25 ng ml−1 for Cu(II) and Co(II) and 20 ng ml−1 for Pb(II). A high preconcentration value of 300 in the case of Mn(II), Co(II), Ni(II), Cu(II),Cd(II) and a value of 500 and 250 for Pb(II) and Zn(II), respectively, were achieved. A recovery of >98% was obtained for all the metal ions with 4 M HCl as eluting agent except in the case of Cu(II) where in 6 M HCl was necessary. The chelating polymer showed low sorption behavior to alkali and alkaline earth metals and also to various inorganic anionic species present in saline matrix. The method was applied for metal ion determination from water samples like seawater, well water and tap water and also from green leafy vegetable, from certified multivitamin tablets and steel samples.  相似文献   

7.
Amberlite XAD-16 resin has been functionalized using nitrosonaphthol as a ligand and characterized employing elemental, thermogravimetric analysis and FT-IR spectroscopy. The sorption of Ni(II) and Cu(II) ions onto this functionalized resin is investigated and optimized with respect to the sorptive medium (pH), shaking speed and equilibration time between liquid and solid phases. The monitoring of the influence of diverse ions on the sorption of metal ions has revealed that phosphate, bicarbonate and citrate reduce the sorption up to 10–14%. The sorption data followed Langmuir, Freundlich, and Dubinin–Radushkevich (D–R) isotherms. The Freundlich parameters computed are 1/n = 0.56 ± 0.03 and 0.49 ± 0.05, A = 9.54 ± 1.5 and 6.0 ± 0.5 mmol g−1 for Ni(II) and Cu(II) ions, respectively. D–R isotherm yields the values of Xm = 0.87 ± 0.07 and 0.35 ± 0.05 mmol g−1 and of E = 9.5 ± 0.23 and 12.3 ± 0.6 kJ mol−1 for Ni(II) and Cu(II) ions, respectively. Langmuir characteristic constants estimated are Q = 0.082 ± 0.005 and 0.063 ± 0.003 mmol g−1, b = (4.7 ± 0.2) × 104 and (7.31 ± 0.11) × 104 l mol−1 for Ni(II) and Cu(II) ions, respectively. The variation of sorption with temperature gives thermodynamic quantities of ΔH = −58.9 ± 0.12 and −40.38 ± 0.11 kJ mol−1, ΔS = −183 ± 10 and −130 ± 8 J mol−1 K−1 and ΔG = −4.4 ± 0.09 and −2.06 ± 0.08 kJ mol−1 at 298 K for Ni(II) and Cu(II) ions, respectively. Using kinetic equations, values of intraparticle transport and of first order rate constant have been computed for both the metal ions. The sorption procedure is utilized to preconcentrate these ions prior to their determination in tea, vegetable oil, hydrogenated oil (ghee) and palm oil by atomic absorption spectrometry using direct and standard addition methods.  相似文献   

8.
A sequential injection analysis (SIA) spectrophotometric method for the determination of trace amounts of zinc(II) with 1-(2-pyridylazo)-2-naphthol (PAN) is described. The method is based on the measurement of absorbance of the zinc(II)–PAN chelate solubilized with a non-ionic surfactant, Triton X-100, no extraction procedure is required in the proposed method, yielding a pink colored complex at pH 9.5 with absorption maximum at 553 nm. The SIA parameters that affect the signal response have been optimized in order to get the better sensitivity and minimum reagent consumption. A linear relationship between the relative peak height and concentration was obtained in the concentration range of 0.1–1.0 μg ml−1. The limit of detection (LOD, defined as 3σ) and limit of quantification (LOQ, defined as 10σ) were 0.02 and 0.06 μg ml−1, respectively. The sample throughput about 40 samples/h was obtained. The repeatability were 1.32 and 1.24% (n = 10) for 0.1 and 0.5 μg ml−1, respectively. The proposed method was successfully applied to the assay of zinc(II) in three samples of multivitamin tablets. The results were found to be in good agreement with those obtained by flame atomic absorption spectrophotometric method and with the claimed values by the manufactures. The t-test showed no significant difference at 95% confidence level.  相似文献   

9.
Zanjanchi MA  Noei H  Moghimi M 《Talanta》2006,70(5):933-939
Diffuse reflectance spectroscopy (DRS) can be used as a rapid and sensitive method for the quantitative determination of low amounts of aluminum. In this analytical technique, the analyte in samples are extracted onto a solid sorbent matrix loaded with a colorimetric reagent and then quantified directly on the adsorbent surface. Alternatively, colored aluminum complexes formed in solution can also be immobilized onto adsorbent surface and be measured by DRS technique. Octadecyl silica disk, methyltrioctylammonium chloride–naphthalene and MCM-41 were examined as adsorbents. Eriochrome cyanine R and quinalizarin were used as coloring reagents. Optimal sorption conditions were found for each system of analyte–reagent–adsorbent. The concentration of analyte is determined using the appropriate form of the Kubelka–Munk function. We obtained for each of the aluminium–reagent–adsorbent system a calibration curve by plotting the absorbance versus the log 102[Al3+] μg ml−1. The linear dynamic range extends over two orders of magnitude within 0.01–15 μg ml−1 with little differences in the range and in the correlation coefficients among the adsorbents. We consider that for a rapid determination of aluminum a spot-test-DRS combination with a detection limit of 1.0 × 10−2 μg ml−1 is the more facile and preferred technique.  相似文献   

10.
A reversed flow injection colorimetric procedure for determining iron(III) at the μg level was proposed. It is based on the reaction between iron(III) with norfloxacin (NRF) in 0.07 mol l−1 ammonium sulfate solution, resulting in an intense yellow complex with a suitable absorption at 435 nm. Optimum conditions for determining iron(III) were investigated by univariate method. The method involved injection of a 150 μl of 0.04% w/v colorimetric reagent solution into a merged streams of sample and/or standard solution containing iron(III) and 0.07 mol l−1 ammonium sulfate in sulfuric acid (pH 3.5) solution which was then passed through a single bead string reactor. Subsequently the absorbance as peak height was monitored at 435 nm. Beer's law obeyed over the range of 0.2–1.4 μg ml−1 iron(III). The method has been applied to the determination of total iron in water samples digested with HNO3–H2O2 (1:9 v/v). Detection limit (3σ) was 0.01 μg ml−1 the sample through of 86 h−1 and the coefficient of variation of 1.77% (n=12) for 1 μg ml−1 Fe(III) were achieved with the recovery of the spiked Fe(III) of 92.6–99.8%.  相似文献   

11.
Rostampour L  Taher MA 《Talanta》2008,75(5):1279-1283
Natural clinoptilolite was used as a sorbent material for solid phase extraction and preconcentration of vanadium. The clinoptilolite was first saturated with a cation such as nickel(II) and then modified with benzyldimethyltetradecyleammonium chloride (BDTA) for increasing sorption of 4-(2-pyridylazo)resorcinol (PAR). Vanadium–PAR complex was quantitatively retained on the sorbent by the column method at the pH range 6.2–7.0 at a flow rate of 1 mL min−1. It was removed from the column with 5.0 mL of dimethylformamide solution at a flow rate of 0.8 mL min−1 and determined by UV–vis spectrophotometry at λmax = 550 nm. 0.031 μg of vanadium can be concentrated from 450 mL of aqueous sample (where detection limit as 0.07 ng mL−1 with preconcentration factor of 90). Relative standard deviation for eight replicate determination of 5.0 μg of vanadium in final solution is 2.1%. The interference of number of anions and cations has been studied in detail to optimize the conditions and method was successfully applied for determination of all vanadium as V(IV) form in standard samples.  相似文献   

12.
Soylak M  Tuzen M  Mendil D  Turkekul I 《Talanta》2006,70(5):1129-1135
A solid phase extraction procedure based on biosorption of copper(II), lead(II), zinc(II), iron(III), nickel(II) and cobalt(II) ions on Aspergillus fumigatus immobilized Diaion HP-2MG has been investigated. The analytical conditions including amounts of A. fumigatus, eluent type, flow rates of sample and eluent solutions were examined. Good recoveries were obtained to the spiked natural waters. The influences of the concomitant ions on the retentions of the analytes were also examined. The detection limits (3sigma, N = 11) were 0.30 μg l−1 for copper, 0.32 μg l−1 for iron, 0.41 μg l−1 for zinc, 0.52 μg l−1 for lead, 0.59 μg l−1 for nickel and 0.72 μg l−1 for cobalt. The relative standard deviations of the procedure were below 7%. The validation of the presented procedure is performed by the analysis of three standard reference materials (NRCC-SLRS 4 Riverine Water, SRM 1515 Apple leaves and GBW 07605 Tea). The procedure was successfully applied for the determination of analyte ions in natural waters microwave digested samples including street dust, tomato paste, black tea, etc.  相似文献   

13.
A sample solution was passed at 20 ml min−1 through a column (150×4 mm2) of Amberlite IRA-410Stron anion-exchange resin for 60 s. After washing, a solution of 0.1% sodium borohydride was passed through the column for 60 s at 5.1 ml min−1. Following a second wash, a solution of 8 mol l−1 hydrochloric acid was passed at 5.1 ml min−1 for 45 s. The hydrogen selenide was stripped from the eluent solution by the addition of an argon flow at 150 ml min−1 and the bulk phases were separated by a glass gas–liquid separator containing glass beads. The gas stream was dried by passing through a Nafion® dryer and fed, via a quartz capillary tube, into the dosing hole of a transversely heated graphite cuvette containing an integrated L’vov platform which had been pretreated with 120 μg of iridium as trapping agent. The furnace was held at a temperature of 250°C during this trapping stage and then stepped to 2000°C for atomization. The calibration was performed with aqueous standards solution of selenium (selenite, SeO32−) with quantification by peak area. A number of experimental parameters, including reagent flow rates and composition., nature of the gas–liquid separator, nature of the anion-exchange resin, column dimensions, argon flow rate and sample pH, were optimized. The effects of a number of possible interferents, both anionic and cationic were studies for a solution of 500 ng 1−1 of selenium. The most severe depressions were caused by iron (III) and mercury (II) for which concentrations of 20 and 10 mg  1−1 caused a 5% depression on the selenium signal. For the other cations (cadmium, cobalt, copper, lead,. magnesium, and nickel) concentrations of 50–70 mg 1−1 could be tolerated. Arsenate interfered at a concentration of 3 mg−1, whereas concentrations of chloride, bromide, iodide, perchlorate, and sulfate of 500–900 mg l−1 could be tolerated. A linear response was obtained between the detection limit of 4 ng 1−1, with a characteristic mass of 130 pg. The RSDs for solutions containing 100 and 200 ng 1−1 selenium were 2.3% and 1.5%, respectively.  相似文献   

14.
Tunçeli A  Türker AR 《Talanta》2002,57(6):1199-1204
A simple and sensitive method for the speciation, separation and preconcentration of Cr(VI) and Cr(III) in tap water was developed. Cr(VI) has been separated from Cr(III) and preconcentrated as its 1,5-diphenylcarbazone complex by using a column containing Amberlite XAD-16 resin and determined by FAAS. Total chromium has also been determined by FAAS after conversion of Cr(III) to Cr(VI) by oxidation with KMnO4. Then, Cr(III) has been calculated by subtracting Cr(VI) from the total. The effect of acidity, amount of adsorbent, eluent type and flow rate of the sample solution on to the preconcentration procedure has been investigated. The retained Cr(VI) complex was eluated with 10 ml of 0.05 mol l−1 H2SO4 solution in methanol. The recovery of Cr(VI) was 99.7±0.7 at 95% confidence level. The highest preconcentration factor was 25 for a 250 ml sample volume. The detection limit of Cr(VI) was found as 45 μg l−1. The adsorption capacity of the resin was found as 0.4 mg g−1 for Cr (VI). The effect of interfering ions has also been studied. The proposed method was applied to tap water samples and chromium species have been determined with the relative error <3%.  相似文献   

15.
Matos RC  Coelho EO  Souza CF  Guedes FA  Matos MA 《Talanta》2006,69(5):1208-1214
The importance of atmospheric hydrogen peroxide (H2O2) in the oxidation of SO2 and other compounds has been well established. A spectrophotometric method for the determination of hydrogen peroxide in rainwater is proposed. This method is based on selective oxidation of hydrogen peroxide using an on-line tubular reactor containing peroxidase immobilized on Amberlite IRA-743 resin. The hydrogen peroxide in the presence of phenol, 4-aminoantipyrine and peroxidase, produces a red compound (λ = 505 nm). Beer's law is obeyed in a concentration range of 1–100 μmol l−1 hydrogen peroxide with an excellent correlation coefficient (r = 0.9991), at pH 7.0, with a relative standard deviation (R.S.D.) <2%. The detection limit of the method is 0.7 μmol l−1 (4.8 ng of H2O2 in a 200 μl sample). Measurements of hydrogen peroxide in rain samples were carried out over the period from November 2003 to January 2005, in the central area of the Juiz de Fora city, Brazil. The concentration of H2O2 varied from values lower than the detection limit to 92.5 μmol l−1. The effects of the presence of nonseasalt (NSS) SO42−, NO3 and H+ in the concentration of hydrogen peroxide in the rainwater had been evaluated. The average concentrations of H2O2, NO3, NSS SO42− and SO42− are 23.4, 18.9, 7.9 and 10.3 μmol l−1, respectively. The pH values for 82% of the collected samples are greater than 5.0. The spectrophotometeric method developed in this work that uses enzyme immobilized on the resin ion-exchange compared with the amperometric method did not present any significant difference in the results.  相似文献   

16.
A new rapid flow injection procedure for the simultaneous determination of nitrate, nitrite and ammonium in single flow injection analysis system is proposed. The procedure combines on-line reduction of nitrate to nitrite and oxidation of ammonium to nitrite with spectrophotometric detection of nitrite by using the Griess-llosvay reaction. The formed azo dye was measured at 543 nm. The influence of reagent concentration and manifold parameters were studied. Nitrite, nitrate and ammonium can be determined within the range of 0.02–1.60 μg mL−1, 0.02–1.60 μg mL−1 and 0.05–1.40 μg mL−1, respectively. R.S.D. values (n = 10) were 2.66; 1.41 and 3.58 for nitrate, nitrite and ammonium, respectively. This procedure allows the determination and speciation of inorganic nitrogen species in soils with a single injection in a simple way, and high sampling rate (18 h−1). Detection limits of 0.013, 0.046 and 0.047 μg mL−1were achieved for nitrate, nitrite and ammonium, respectively. In comparison with others methods, the proposed one is more simple, it uses as single chromogenic reagent less injection volume (250 mL in stead of 350 mL) and it has a higher sampling rate.  相似文献   

17.
An extremely sensitive, reliable and simple procedure is described for the determination of physiological palladium, platinum and gold in human urine. The urine samples were adjusted to pH 4 (Pd, Au) or pH 5 (Pt), followed by conversion of the analytes to their pyrrolidinedithiocarbamate complexes. These complexes were separated from the matrix by liquid-liquid extraction into 4-methyl-2-pentanone resulting in a 25-fold enrichment. Determination was by electrothermal atomic absorption spectrometry (ET-AAS) using longitudinal inverse alternating current Zeeman-effect background correction. The limits of detection calculated from three standard deviations of the blank values were 20 ng l−1 for Pd and Au and 70 ng l−1 Pt. Within-day precision (n = 10, 5 μg l−1) ranged 5.2%–7.7%. The procedure is successfully applied to determine urinary palladium, platinum and gold in nine unexposed persons. Palladium levels in urine ranged < 20–80 ng l−1 (arithmetical MEAN=38.7 ng l−1), while gold levels ranged < 20–130 ng l−1 (36.0 ng l−1). Physiological platinum levels in urine were all < 70 ng l−1. The accuracy of the procedure was checked by analyzing a series of urine samples by a second independent method (magnetic sector field inductively-coupled plasma-mass spectrometry) in combination with UV photolysis.  相似文献   

18.
A flow injection procedure for the separation and pre-concentration of inorganic arsenic based on the complexation with ammonium diethyl dithiophosphate (DDTP) and sorption on a C-18 bonded silica gel minicolumn is proposed. During the sample injection by a time-based fashion, the As3+-DDTP complex is stripped from the solution and retained in the column. Arsenic(V) and other ions that do not form complexes are discarded. After reduction to the trivalent state by using potassium iodide plus ascorbic acid, total arsenic is determined by electrothermal atomic absorption spectrometry (ETAAS). Arsenic(V) concentration can be calculated by difference. After processing 6 ml sample volume, the As3+-DDTP complexes were eluted directly into the autosampler cup (120 μl). Ethanol was used for column rinsing. Influence of pH, reagent concentration, pre-concentration and elution time and column size were investigated. When 30 μl of eluate plus 10 μl of 0.1% (w/v) Pd(NO3)2 were dispensed into the graphite tube, analytical curve in the 0.3–3 μg As l−1 range was obtained (r=0.9991). The accuracy was checked for arsenic determination in a certified water, spiked tap water and synthetic mixtures of arsenite and arsenate. Good recoveries (97–108%) of spiked samples were found. Results are precise (RSD 7.5 and 6% for 0.5 and 2.5 μg l−1, n=10) and in agreement with the certified value of reference material at 95% confidence level.  相似文献   

19.
Methods for the determination of aluminium and manganese in human scalp hair samples by electrothermal atomic absorption spectrometry using the slurry sampling technique were developed. Palladium and magnesium nitrate were used as chemical modifiers. Hair samples were pulverized using a zirconia vibrational mill ball, and were prepared as aqueous slurries. Determinations can be performed in the linear ranges of 1.9–150 μg l−1 Al3+ and 0.03–10.0 μg l−1 Mn2+. Limits of detection of 0.9 mg kg−1 and 27.6 μg kg−1 were obtained for aluminium and manganese, respectively. The analytical recoveries were between 99.6 and 101.8% for aluminium and in the 98.3–101.3% range for manganese. The repeatability of the methods (n=11), slurry preparation procedure and ETAAS measurement, was 16.0 and 7.9% for aluminium and manganese, respectively. The methods were finally applied to the aluminium and manganese determination in 25 scalp hair samples from healthy adults. The levels for aluminium were between 8.21 and 74.08 mg kg−1, while concentrations between 0.03 and 1.20 mg kg−1 were found for manganese.  相似文献   

20.
A simple GF-AAS method for speciation analysis of chromium in mineral waters and salinas was developed. Cr(VI) species were separated from Cr(III) by solid-phase extraction with APDC (ammonium pyrrolidinedithiocarbamate). The APDC complexes were formed in the sample solution under proper conditions, adsorbed on Diaion HP-2MG resin and the resin was separated from the sample. After elution with concentrated nitric acid Cr(VI) was determined by GF-AAS. Total chromium was determined by GF-AAS directly in the sample and Cr(III) concentration was calculated as the difference between those results.

The detection limit of the method defined as 3 s of background variation was 0.03 μg l−1 for Cr(VI) and 0.3 μg l−1 for total chromium. RSD for Cr(VI) determination at the concentration of 0.14 μg l−1 was 9%, and for total chromium at the concentration of 5.6 μg l−1 was 5%. The recovery of Cr(VI) was in the range of 94–100%, dependently on type of the sample.

The investigation of recovery of the spiked Cr(VI) showed that at concentration levels near 1 μg l−1 and lower recovery may be reduced significantly even by pure reagents that seem to be free from any reductants.  相似文献   


设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号