首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
The activities of enkephalin-degrading peptidases such as enkephalinases A and B in rat brain tissues were simultaneously assayed by a high-performance liquid chromatographic method with fluorimetric detection with an automatic reaction system. Tyrosine and tyrosine-containing peptides produced enzymatically from the substrate, methionine-enkephaline, were separated by gradient elution on a reversed-phase column (TSK gel ODS-120T), and then converted into fluorescent derivatives for detection by reaction with hydroxylamine, cobalt(II) and borate reagents. The method permits the simple and sensitive detection of N-terminal tyrosine-containing fragments of the enkephalin peptide. The limits of detection are 5-20 pmol per assay tube for the N-terminal tyrosine-containing fragments. The enzyme activities in the regionally separated tissues were 54-191 pmol/min.mg protein for enkephalinase A and 79-153 pmol/min.mg protein for enkephalinase B, which were calculated from the formation of Tyr-Gly-Gly and Tyr-Gly, respectively, during the enzyme reaction.  相似文献   

2.
A pre-column fluorescence derivatization method is described for the high-performance liquid chromatographic determination of tyrosine-containing peptides. A tyrosyl residue in the peptide is first formylated in an alkaline medium in the presence of chloroform, and the resulting aldehyde is then converted into a fluorescent derivative by reaction with 1,2-diamino-4,5-dimethoxybenzene. The derivative is separated on a reversed-phase column (LiChrosorb RP-18) by isocratic elution with an aqueous acetonitrile-containing potassium chloride-hydrochloric acid buffer (pH 2.2) and sodium 1-hexanesulphonate. The method is selective and fairly sensitive; the lower limits of detection for the tyrosine-containing peptides tested are in the range 3.4-26.2 pmol in a 100-microliter injection volume.  相似文献   

3.
A fluorimetric method is proposed for determining N-terminal tyrosine-containing peptides, of which some peptides such as enkephalins and kyotorphin are of physiological importance. An intense fluorescence is produced when the peptide is heated at 100°C for 3 min in a weakly alkaline medium containing borate, hydroxylamine and cobalt(II). The fluorescent species is stabilized with β-mercaptoethanol, with excitation and emission maxima at 335 and 430 nm, respectively. The method is highly selective for N-terminal tyrosine-containing peptides, with a detection limit of 43–69 pmol ml?1.  相似文献   

4.
A selective and sensitive fluorometric determination method for native fluorescent peptides has been developed. This method is based on intramolecular fluorescence resonance energy transfer (FRET) detection in a liquid chromatography (LC) system following precolumn derivatization of the amino groups of tryptophan (Trp)-containing peptides. In this detection process, we monitored the FRET from the native fluorescent Trp moieties (donor) to the derivatized fluorophore (acceptor). From a screening study involving 10 fluorescent reagents, we found that o-phthalaldehyde (OPA) generated FRET most effectively. The OPA derivatives of the native fluorescent peptides emitted OPA fluorescence (445 nm) through an intramolecular FRET process when they were excited at the excitation maximum wavelength of the Trp-containing peptides (280 nm). The generation of FRET was confirmed through comparison with the analysis of a non-fluorescent peptide (C-reactive protein fragment (77 - 82)) performed using LC and a three-dimensional fluorescence detection system. We were able to separate the OPA derivatives of the Trp-containing peptides when performing LC on a reversed-phase column. The detection limits (signal-to-noise ratio = 3) for the Trp-containing peptides, at a 20-microL injection volume, were 41 - 180 fmol. The sensitivity of the intramolecular FRET-forming derivatization method is higher than that of the system that takes advantage of the conventional detection of OPA derivatives. Moreover, native non-fluorescent amines and peptides in the sample monitored at FRET detection are weaker than those of conventional fluorescence detection.  相似文献   

5.
Peptides containing a free alpha- or epsilon-amino group react with fluorescamine under mild alkaline conditions to generate a highly fluorescent but unstable reaction product and, consequently, practical high-performance liquid chromatographic (HPLC) approaches to analysis have typically involved the use of postcolumn derivatization. An automated precolumn approach is reported in which peptides are reacted with fluorescamine just prior to HPLC analysis by a commercially available autoinjector with derivatization capabilities. The autoinjector added base and fluorescamine reagent solutions to a sample vial containing peptide analytes, and the derivatization reaction was allowed to proceed for 5 min at room temperature prior to injection into the HPLC system. The derivatized peptides were analyzed by reversed-phase HPLC with fluorescence detection (excitation at 390 nm; emission 470-nm cut-off filter) on an octylsilica column. Optimization of the precolumn reaction conditions and the use of narrower HPLC columns (2 mm I.D.) resulted in a typical on-column detection limit of 30-50 fmol of peptide, which was substantially lower than that in previously reported post-column methods. This approach was applied to the HPLC of several naturally occurring and synthetic peptides containing alpha- and epsilon-amino groups. In combination with solid-phase extraction, prior to automated precolumn fluorescence derivatization and chromatographic analysis, the methodology was used for the determination of a synthetic growth hormone-releasing peptide in plasma samples.  相似文献   

6.
A reversed-phase high-performance liquid chromatographic (HPLC) assay method has been developed for determining pirlimycin in human serum and urine. The method involves chloroform extraction of pirlimycin free base followed by derivatization with 9-fluorenylmethylchloroformate to form a carbamate ester. The reaction is rapid, reproducible, and quantitative. 9-Fluorenylmethylchloroformate reacts with amines to form derivatives sensitive to both ultraviolet and fluorescence detection. Human serum and urine samples following 50-mg and 500-mg single oral doses of pirlimycin were analyzed. The samples were chromatographed on an RP-18 Spherisorb 5-micron, 250 X 4.6 mm I.D. reversed-phase HPLC column. The eluent for the serum assay was acetonitrile-water (58:42) containing 0.02% acetic acid, and for the urine assay was acetonitrile-methanol-tetrahydrofuran-water (48:2:1:49). Fluoranthene was used as an internal standard. The assay sensitivity by ultraviolet detection (lambda max = 264) was about 5 ng/ml and by fluorescence detection (lambda excitation = 270 nm, lambda emission = 300 nm) was 0.1 ng/ml. Statistical analysis indicates an average drug recovery of 101 +/- 4.2% from serum and 102.0 +/- 2.62% from urine.  相似文献   

7.
The reversible labeling of tyrosine (Tyr)-containing peptide, which involves detection and recovery, is described in this paper. The phenolic-OH in Tyr structure reacted with 4-fluoro-7-nitro-2,1,3-benzoxadiazole (NBD-F) under a mild condition at room temperature in alkaline medium. The resulting derivative absorbed at around 280 nm and 380 nm. However, the fluorescence was very weak. The NBD moiety in the derivative was efficiently removed by the treatment of N-acetyl-L-cysteine (N-AcCys), and the original peptide before the labeling was completely recovered. The proposed procedure was successfully applied to the reversible labeling of N-terminal amine-blocked peptides, i.e., N-AcTyr-Val-Gly, Z-Glu-Tyr, Z-Phe-Tyr, N-Formyl-Met-Leu-Tyr, and N-AcArg-Pro-Pro-Gly-Phe-Ser-Pro-Tyr-Arg. Although the proposed method could not recover the N-terminal amine-free peptides without blocking, the selective detection and the recovery of Tyr-containing peptide fragments were possible by the combination with enzyme digestion. The reversible labeling of Tyr-containing peptide was demonstrated with [Tyr8]-bradykinin as a model for high-molecular-mass peptides and proteins. The peptide fragments containing NBD-O-Tyr moiety, obtained after the digestion, were easily discriminated from various peptides with the monitoring of UV and FL, because the target peptide did not fluoresce, but absorbed at both 280 nm and 380 nm. The peptide fragment containing Tyr was finally recovered from the de-labeling reaction with N-AcCys. The proposed method hence provides a novel technique for the reversible labeling of Tyr-containing peptides, which will enable the selective detection and the recovery of the original peptide.  相似文献   

8.
The development of selective derivatization for the determination of carboxylic acids, amino acids and peptides in aqueous solutions is described as a preliminary study for the determination of these compounds in biological materials. The derivatization reactions are completed before the liquid chromatographic separation and laser-induced fluorescence detection for which a continuous-wave argon-ion gas laser is used in the ultraviolet or visble mode. Carboxylic acid groups arre derivatized with 9-hydroxymethylathracene and primary amino groups are derivatized with fluorescein isothiocyanate. Detection limits, in aqueous solutions, for the carboxylic acid derivatives are ca. 190 fg (ultraviolet mode). In the visible mode, the detection limits are ca. 1 fg for the primary amino derivatives of amino acids and peptides. In al the chromatographic analyses, the derivatization mixtures are injected onto a standard reversed-phase or reversed- phase ion-pair system and conventional flow cells are used without expensive photon counting or optical systems.  相似文献   

9.
Two new methods for the determination of the cortisol production rate using reversed-phase high-performance liquid chromatography are described. One uses ultraviolet detection at 205 nm, the other on-line post-column derivatization with benzamidine, followed by fluorimetric detection. The specific activity of tetrahydrocortisol and tetrahydrocortisone in urine from patients who had received tritium-labelled cortisol was determined by the indicated methods, followed by fraction collection and liquid scintillation counting. The post-column reaction detection procedure was superior to ultraviolet detection, both in selectivity and analysis time. Intra- and inter-assay variance of the post-column reaction detection procedure were 3.7 and 4.7%, respectively. A good correlation (r = 0.99) was obtained between values determined by this procedure and by a thin-layer chromatographic procedure.  相似文献   

10.
The performance of a number of normal phase and reversed-phase systems, with ultraviolet detection at 360 nm, has been investigated with respect to their applicability to pharmacokinetic studies of mitomycin C (MMC). The reversed-phase system developed was also combined with a polarographic detector in order to compare the sensitivity and selectivity of ultraviolet and electrochemical detection. A simple isolation procedure, based on the adsorption of MMC on a non-ionogenic resin, has been developed. The developed assay is applied to a pharmacokinetic study from which some examples are given.  相似文献   

11.
A highly sensitive and selective fluorometric determination method for ornithine and lysine has been developed. This method is based on an intramolecular excimer-forming fluorescence derivatization with a pyrene reagent, 4-(1-pyrene)butyric acid N-hydroxysuccinimide ester (PSE), followed by reversed-phase liquid chromatography (LC). The analytes, containing two amino moieties in a molecule, were converted to the corresponding dipyrene-labeled derivatives by reaction with PSE. The derivatives afforded intramolecular excimer fluorescence (450-550 nm) which can clearly be discriminated from the normal fluorescence (370-420 nm) emitted from PSE and monopyrene-labeled derivatives of monoamines. The structures of the derivatives and the emission of excimer fluorescence were confirmed by LC with mass spectrometry and with three-dimensional fluorescence detection system, respectively. The PSE derivatives of ornithine and lysine could be separated by reversed-phase LC on ODS column with isocratic elution. The detection limits (signal-to-noise ratio = 3) for ornithine and lysine were 3.5 and 3.7 fmol, respectively, for a 20-microl injection. Furthermore, this method had enough selectivity and sensitivity for the determination of ornithine and lysine in normal human urine.  相似文献   

12.
Ning  Shujing  You  Jinmao  Sun  Zhiwei  Zhang  Shijuan  Ji  Zhongyin 《Chromatographia》2012,75(19):1107-1116

A simple and sensitive method for the determination of free aliphatic amines using 10-phenyl-acridone-2-sulfonyl chloride (PASC) as a labeling reagent by high-performance liquid chromatography with fluorescence detection and online mass spectrometry identification (HPLC-FLD-MS) has been developed. Derivatization conditions including reagent concentration, buffer pH, reaction time and temperature were optimized. PASC reacted with aliphatic amines at 50 °C for 4 min in aqueous acetonitrile (ACN) in the presence of sodiumtetraborate–NaOH buffer (0.10 mol L−1, pH 9.0) to give high yields of PASC-amine derivatives. Derivatives exhibited intense fluorescence with an excitation maximum at λex 265 nm and an emission maximum at λem 418 nm. The separation of derivatives was performed by a reversed-phase Hypersil BDS C8 column in combination with a gradient elution. The identification of derivatives was carried out by online post-column mass spectrometry with atmospheric pressure chemical ionization (APCI) source in positive-ion detection mode. Excellent linear responses were observed with the correlation coefficients of larger than 0.9997, and detection limits (at a signal-to-noise of 3:1) were from 3.0 to 24.3 fmol. Comparing with 10-ethyl-acridine-2-sulfonyl chloride (EASC), PASC exhibited more intense fluorescence and ultraviolet absorbance. The proposed method is sensitive and reproducible for the determination of aliphatic amines from water and soil samples.

  相似文献   

13.
合成了新型高灵敏度的荧光标记试剂10-乙基吖啶酮-2-磺酰氯(EASC)。采用EASC柱前衍生化实现了雌二醇(E2)和雌三醇(E3)的反相高效液相色谱(RP-HPLC)-荧光分析及柱后质谱鉴定。试剂EASC比丹磺酰氯(DNS-Cl)具有更高的紫外、荧光和质谱检测灵敏度,其荧光发光强度是丹磺酰氯的1000倍以上。EASC与E2和E3在NaHCO3缓冲液(pH 10.5)中,于60 ℃下反应3 min即可获得稳定的荧光产物,最大激发波长(λex)和最大发射波长(λem)分别为270 nm和430 nm。所建立的方法具有良好的重现性,线性回归系数大于0.9990;检出限(S/N=3)为31 fmol 和40 fmol。对实际根田鼠尿样中的雌二醇和雌三醇含量进行了测定,结果令人满意。  相似文献   

14.
衍生反相离子对色谱法同时分离检测多糖中单糖及糖醛酸组成的方法,筛选出适合于p-AMBA糖衍生物分离的色谱柱,考察了流动相组成对9种单糖和两种糖醛酸的p-AMBA衍生化产物的保留值及分离的影响,优化了反应温度和反应时间等衍生化条件,并应用优化的分析方法测定了螺旋藻中的单糖和糖醛酸的组成。采用紫外检测时,方法的检出限为 (2.55~13.4)×107mol/L;采用荧光检测时,方法的检出限为(3.38~176)×108 mol/L。  相似文献   

15.
We have previously reported the development of a far-ultraviolet (FUV) absorbance detector capable of detecting wavelengths down to 175 nm in high-performance liquid chromatography (HPLC). Although the FUV detector can detect substances with weak to non-existent ultraviolet (UV) absorption (e.g., sugars at 185 nm and peptides at 190 nm), a large baseline drift occurs in the gradient elution due to differences in the FUV absorbance properties of water and acetonitrile. To overcome the problem of baseline drift, we have proposed a new baseline correction method using the absorption of water at 1450 nm. It is well known that water has a relatively large absorption peak at 1450 nm in the near-infrared (NIR) region. By contrast, acetonitrile used in reversed-phase HPLC shows negligible absorbance compared to water at 1450 nm. Sugars and peptides also show negligible absorbance at 1450 nm. Thus, it is expected that changes in absorbance at 1450 nm only reflect the volume fraction of water in the gradient elution. The baseline correction method by a linear combination of FUV and NIR chromatograms was applied to the HPLC separation of sugars and peptides in water/acetonitrile-gradient HPLC coupled with FUV detection. The results showed that flat baselines were successfully obtained in the gradient HPLC coupled with FUV detection.  相似文献   

16.
A highly sensitive method for the determination of bisphenol-A in water with semi-micro column high-performance liquid chromatography using 2-methoxy-4-(2-phthalimidinyl)phenylsulfonyl chloride as a fluorescent labeling reagent has been developed. The labeling reaction was carried out at 70 degrees C for 20 min in borate buffer (pH 9.5). The derivative eluted at 11.6 min on a reversed-phase column with methanol-water (78:22, v/v) at a flow-rate of 0.2 ml/min. The fluorescence was monitored at 308 nm for excitation and 410 nm for emission. The detection limit (S/N = 3) was 10 fmol per injection. The labeling yield was about 95%.  相似文献   

17.
Narciclasine was determined in the blood of mice by reversed-phase high-performance liquid chromatography, using a C18 stationary phase and a mobile phase of methanol-0.025 M potassium dihydrogen phosphate (50:50, v/v) of pH 5.5. Amperometric detection at a carbon fibre array working electrode held at +1.8 V (Ag/AgCl) permitted determination down to concentrations of 10 and 15.4 ng ml-1 (at a signal-to-noise ratio of 2) in aqueous solution and in serum, respectively. Fluorescence detection (excitation and emission wavelengths of 360 and 480 nm, respectively) exhibited somewhat poorer sensitivities for aqueous and serum samples: the respective limits of detection were 25 and 32 ng ml-1 at a signal-to-noise ratio of 2. Both the amperometric and the fluorescence detection were free from interference from blood components, but the fluorescence measurement required a post-column pH adjustment. UV photometric detection at 254 nm exhibited detection limits of 15 and 65 ng ml-1 in aqueous samples and in serum, respectively, and suffered from interferences from blood components that strongly absorbed in the ultraviolet region. All three detection techniques exhibited good linearity and precision.  相似文献   

18.
A sensitive method for the detection, quantitation and purification of peptides is described. The method is based on pre-column derivatization of peptides with phenyl isothiocyanate to form phenylthiocarbamoyl derivatives (PTC peptides). The derivatized peptides are analysed by reversed-phase high-performance liquid chromatography on a Zorbax ODS column (5 micron) and detected at 269 nm with a sensitivity limit of 1-5 pmol. The technique was utilized for the separation of a mixture of closely related synthetic peptides. The eluted PTC peptides were collected with an average recovery yield of 75% as determined by amino acid analysis. This method of separation of PTC peptides was also combined with the determination of the complete structure of recovered PTC-dynorphin A-(1-13) using the solid-phase sequenator (Sequemat). The advantages of the derivatization method are the rapidity and completeness of the reaction, the stability of the product, the sensitivity and specificity of the detection of derivatized peptides and the compatibility of the technique with subsequent analytical procedures. A particular application of this method was exemplified by the dosage of enkephalins secreted from perfused bovine adrenal glands.  相似文献   

19.
A highly sensitive and selective fluorimetric determination method for dicarboxylic acids (C5-C12) has been developed. This method is based on an intramolecular excimer-forming fluorescence derivatization with a pyrene reagent, 4-(1-pyrene)butyric acid hydrazide (PBH), followed by reversed-phase liquid chromatography (LC). The carboxylic acids were converted to the corresponding dipyrene-labeled derivatives by reaction with PBH in the presence of 1-ethyl-3-(3-dimethylaminopropyl)carbodiimide. The derivatives afforded intramolecular excimer fluorescence (450-550 nm) which can clearly be discriminated from the normal fluorescence (370-420 nm) emitted from PBH and monopyrene-labeled derivatives of monocarboxylic acids. The structures of the derivatives and the emission of excimer fluorescence were studied by LC with mass spectrometry and with spectrofluorimetry, respectively. The PBH derivatives of the carboxylic acids could be separated by reversed-phase LC on an ODS column with isocratic elution. The detection limits (signal-to-noise ratio = 3) were 1.3 fmol to undetectable for a 20-microl injection.  相似文献   

20.
Two high-performance liquid chromatographic analytical methods have been developed for the measurement of dl-sotalol or d-sotalol and l-sotalol in plasma, using dl-atenolol as internal standard. Quantitation of dl-sotalol was carried out, following solid-phase extraction, on a 5-microns C18 reversed-phase column, with a mobile phase containing acetonitrile, ion-pairing reagent and distilled water, using ultraviolet detection at 235 nm. Quantitation of d-sotalol and l-sotalol was based on derivatisation with the chiral agent S-(-)-alpha-methylbenzyl isocyanate, followed by chromatographic separation on a 3-microns C18 reversed-phase column, with a mobile phase containing methanol, glacial acetic acid and distilled water, with fluorimetric detection at 220 nm excitation and 300 nm emission. A preliminary application of the latter method suggests that the disposition of sotalol in humans is not enantioselective.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏