首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
The concentrations of l ‐tryptophan (Trp) and the metabolite l ‐kynurenine (KYN) can be used to evaluate the in‐vivo activity of indoleamine 2,3‐dioxygenase (IDO) and tryptophan 2,3‐dioxygenase (TDO). As such, a novel method involving derivatization of l ‐Trp and l ‐KYN with (R)‐4‐(3‐isothiocyanatopyrrolidin‐1‐yl)‐7‐(N,N‐dimethylaminosulfonyl)‐2,1,3‐benzoxadiazole (DBD‐PyNCS) and separation by high‐performance liquid chromatography (HPLC) with tandem mass spectrometric (MS/MS) detection on a triazole‐bonded column (Cosmosil HILIC®) was developed to determine their concentrations. The optimized mobile phase, CH3CN/10 mm ammonium formate in H2O (pH 5.0) (90:10, v/v) eluted isocratically, resulted in satisfactory separation and MS/MS detection of the analytes. The detection limits of l ‐Trp and l ‐KYN were approximately 50 and 4.0 pm , respectively. The column temperature affected the retention behaviour of the Trp and KYN derivatives, with increased column temperatures leading to increased capacity factors; positive enthalpy changes were revealed by van't Hoff plot analyses. Using the proposed LC‐MS/MS method, l ‐Trp and l ‐KYN were successfully determined in 10 μL human serum using 1‐methyl‐l ‐Trp as an internal standard. The precision and recovery of l ‐Trp were in the ranges 2.85–9.29 and 95.8–113%, respectively, while those of l ‐KYN were 2.51–16.0 and 80.8–98.2%, respectively. The proposed LC‐MS/MS method will be useful for evaluating the in vivo activity of IDO or TDO. Copyright © 2016 John Wiley & Sons, Ltd.  相似文献   

2.
Enantiomeric separation of d ‐ and l ‐serine on an octadecylsilica column was investigated using (2R)‐2,5‐dioxopyrrolidin‐1‐yl‐2,5,7,8‐tetramethyl‐6‐(tetrahydro‐2H‐pyran‐2‐yloxy)chroman‐2‐carboxylate (R‐NPCA), which was developed for a pre‐column derivatization reagent for electrochemical detection. In addition, (2S)‐2,5‐dioxopyrrolidin‐1‐yl‐2,5,7,8‐tetramethyl‐6‐(tetrahydro‐2H‐pyran‐2‐yloxy)chroman‐2‐carboxylate (S‐NPCA) was newly synthesized from (S)‐(?)‐6‐hydroxy‐2,5,7,8‐tetramethylchroman‐2‐carboxylic acid (Sα‐CA), and the enantiomeric separation of d ‐ and l ‐serine using S‐NPCA was also examined. The enantiomeric separation of d ,l ‐serine was achieved using the R‐ or S‐NPCA as a chiral derivatization reagent, and the elution orders of the enantiomers were reversed between R‐ and S‐NPCA. The elution orders of d ‐ and l ‐serine unexpectedly reversed between the phosphate buffer at pH 4.0 and pH 2.2, both of which were used in the mobile phase. Separation factors obtained using R‐ and S‐NPCA were similar—1.09 and 1.07, respectively. The detection limit was approximately 940 fmol on the column (signal‐to‐noise ratio 3) when the applied voltage was +650 mV. Copyright © 2009 John Wiley & Sons, Ltd.  相似文献   

3.
Elution profiles of kynurenic acid (KYNA) and 7‐chlorokynurenic acid (Cl‐KYNA) were examined by high‐performance liquid chromatography (HPLC) using a triazole‐bonded stationary phase column (Cosmosil® HILIC) under isocratic elution of a mobile phase consisting of CH3CN–aqueous 10 mm ammonium formate between pH 3.0 and 6.0. The capacity factors of KYNA and Cl‐KYNA varied with both the CH3CN content and the pH of the mobile phase. The elution order of KYNA and Cl‐KYNA was reversed between the CH3CN‐ and H2O‐rich mobile phases, suggesting that hydrophilic interactions and anion‐exchange interactions caused retention of KYNA and Cl‐KYNA in the CH3CN‐ and H2O‐rich mobile phases, respectively. The present HPLC method using a triazole‐bonded column and fluorescence detection (excitation 250 nm, emission 398 nm) was applied to monitor in vitro production of KYNA from d ‐kynurenine (d ‐KYN) by d ‐amino acid oxidase (DAO) using Cl‐KYNA as an internal standard. A single KYNA peak was clearly observed after enzymatic reaction of d ‐KYN with DAO. Production of KYNA from d ‐KYN was suppressed by the addition of commercial DAO inhibitors. The present HPLC method can be used to evaluate DAO activity and DAO inhibitory effects in candidate drugs for the treatment of schizophrenia. Copyright © 2015 John Wiley & Sons, Ltd.  相似文献   

4.
Enantioresolution of the calcimimetic drug (R,S)‐Cinacalcet was achieved using both indirect and direct approaches. Six chiral variants of Marfey's reagent having l ‐Ala‐NH2, l ‐Phe‐NH2, l ‐Val‐NH2, l ‐Leu‐NH2, l ‐Met‐NH2 and d ‐Phg‐NH2 as chiral auxiliaries were used as derivatizing reagents under microwave irradiation. Derivatization conditions were optimized. Reversed‐phase high‐performance liquid chromatography was successful using binary mixtures of aqueous trifluoroacetic acid and acetonitrile for separation of diastereomeric pairs with detection at 340 nm. Thin silica gel layers impregnated with optically pure l ‐histidine and l ‐arginine were used for direct resolution of enantiomers. The limit of detection was found to be 60 pmol in HPLC while in TLC it was found to be in the range of 0.26–0.28 µg for each enantiomers. Copyright © 2010 John Wiley & Sons, Ltd.  相似文献   

5.
A method for the detection of unlabeled and 15N2‐labeled l ‐tryptophan (l ‐Trp), l ‐kynurenine (l ‐Kyn), serotonin (5‐HT) and quinolinic acid (QA) in human and rat plasma by GC/MS is described. Labeled and unlabeled versions of these four products were analyzed as their acyl substitution derivatives using pentafluoropropionic anhydride and 2,2,3,3,3‐pentafluoro‐1‐propanol. Products were then separated by GC and analyzed by selected ion monitoring using negative ion chemical ionization mass spectrometry. l ‐[13C11, 15N2]‐Trp, methyl‐serotonin and 3,5‐pyridinedicarboxylic acid were used as internal standards for this method. The coefficients of variation for inter‐assay repeatability were found to be approximately 5.2% for l ‐Trp and 15N2‐Trp, 17.1% for l ‐Kyn, 16.9% for 5‐HT and 5.8% for QA (n = 2). We used this method to determine isotope enrichments in plasma l ‐Trp over the course of a continuous, intravenous infusion of l ‐[15N2]Trp in pregnant rat in the fasting state. Plasma 15N2‐Trp enrichment reached a plateau at 120 min. The free Trp appearance rate (Ra) into plasma was 49.5 ± 3.35 µmol/kg/h. The GC/MS method was applied to determine the enrichment of 15N‐labeled l ‐Trp, l ‐Kyn, 5‐HT and QA concurrently with the concentration of non‐labeled l ‐Trp, l ‐Kyn, 5‐HT and QA in plasma. This method may help improve our understanding on l ‐Trp metabolism in vivo in animals and humans and potentially reveal the relative contribution of the four pathways of l ‐Trp metabolism. Copyright © 2014 John Wiley & Sons, Ltd.  相似文献   

6.
d ‐Aspartate (d ‐Asp) and N‐methyl‐d ‐aspartate (NMDA) occur in the neuroendocrine systems of vertebrates and invertebrates, where they play a role in hormone release and synthesis, neurotransmission, and memory and learning. N‐methyl‐d ‐glutamate (NMDG) has also been detected in marine bivalves. Several methods have been used to detect these amino acids, but they require pretreatment of tissue samples with o‐phthaldialdehyde (OPA) to remove primary amino acids that interfere with the detection of NMDA and NMDG. We report here a one‐step derivatization procedure with the chiral reagent N‐α‐(5‐fluoro‐2,4‐dinitrophenyl)‐(d or l )‐valine amide, FDNP‐Val‐NH2, a close analog of Marfey's reagent but with better resolution and higher molar absorptivity. The diastereomers formed were separated by HPLC on an ODS‐Hypersil column eluted with TFA/water–TFA/MeCN. UV absorption at 340 nm permitted detection levels as low as 5–10 pmol. d ‐Asp, NMDA and NMDG peaks were not obscured by other primary or secondary amino acids; hence pretreatment of tissues with OPA was not required. This method is highly reliable and fast (less than 40 min HPLC run). Using this method, we detected d ‐Asp, NMDA and NMDG in several biological tissues (octopus brain, optical lobe and bucchal mass; foot and mantle of the mollusk Scapharca broughtonii), confirming the results of other researchers. Copyright © 2009 John Wiley & Sons, Ltd.  相似文献   

7.
A sequential online extraction, clean‐up and separation system for the determination of betaine, l ‐carnitine and choline in human urine using column‐switching ion chromatography with nonsuppressed conductivity detection was developed in this work. A self‐packed pretreatment column (50 × 4.6 mm, i.d.) was used for the extraction and clean‐up of betaine, l ‐carnitine and choline. The separation was achieved using self‐packed cationic exchange column (150 × 4.6 mm, i.d.), followed by nonsuppressed conductivity detection. Under optimized experimental conditions, the developed method presented good analytical performance, with excellent linearity in the range of 0.60–100 μg mL−1 for betaine, 0.75–100 μg mL−1 for l ‐carnitine and 0.50–100 μg mL−1 for choline, with all correlation coefficients (R2) >0.99 in urine. The limits of detection were 0.15 μg mL−1 for betaine, 0.20 μg mL−1 for l ‐carnitine and 0.09 μg mL−1 for choline. The intra‐ and inter‐day accuracy and precision for all quality controls were within ±10.32 and ±9.05%, respectively. Satisfactory recovery was observed between 92.8 and 102.0%. The validated method was successfully applied to the detection of urinary samples from 10 healthy people. The values detected in human urine using the proposed method showed good agreement with the measurement reported previously.  相似文献   

8.
Polystyrene (PS) nanoparticles coated by BSA, hereafter denoted as PS/BSA, were prepared and chemically immobilized for the first time onto a capillary inner wall for open‐tubular CEC (OTCEC). EOF and scanning electron micrography were used to characterize the prepared nanoparticle‐coated capillaries. To investigate the performance of the prepared columns in OTCEC, chiral separation of d ,l ‐tryptophan (dl ‐Trp) was performed in monolayer BSA‐modified capillary and PS/BSA nanoparticle‐coated columns. The results indicated that the nanoparticle‐modified column afforded a higher resolution compared with the monolayer type. Rapid enantioseparation of dl ‐Trp (within 3 min) was achieved with the PS/BSA‐immobilized column using an electroosmotic pump‐assisted CEC. Enantiomer separations of other compounds like dl ‐tyrosine and warfarin were also achieved with the column. Besides, run‐to‐run and column‐to‐column repeatabilities of the PS/BSA‐coated column in the chiral separation were systematically introduced.  相似文献   

9.
A new pre‐column derivative high‐performance liquid chromatography (HPLC) method for determination of d ‐glucose with 3‐O‐methyl‐d ‐glucose (3‐OMG) as the internal standard was developed and validated in order to study the gluconeogenesis in HepG2 cells. Samples were derivatized with 1‐phenyl‐3‐methy‐5‐pyrazolone at 70°C for 50 min. Glucose and 3‐OMG were extracted by liquid–liquid extraction and separated on a YMC‐Triart C18 column, with a gradient mobile phase composed of acetonitrile and 20 mm ammonium acetate solution containing 0.09% tri‐ethylamine at a flow rate of 1.0 mL/min. The eluate were detected using a UV detector at 250 nm. The assay was linear over the range 0.39–25 μm (R2 = 0.9997, n = 5) and the lower limit of quantitation was 0.39 μm (0.070 mg/mL). Intra‐ and inter‐day precision and accuracy were <15% and within ±3%, respectively. After validation, the HPLC method was applied to investigate the gluconeogenesis in Dulbecco's modified Eagle medium (DMEM) cultured HepG2 cells. Glucose concentration was determined to be about 1–2.5 μm in this gluconeogenesis assay. In conclusion, this method has been shown to determine small amounts of glucose in DMEM successfully, with lower limit of quantitation and better sensitivity when compared with common commercial glucose assay kits. Copyright © 2015 John Wiley & Sons, Ltd.  相似文献   

10.
A simple, accurate, and reproducible HPLC‐UV method has been developed and validated for the quantification of levodopa (l ‐Dopa) in human plasma. The method involves a simple protein precipitation procedure to extract both l ‐Dopa and methyldopa, the internal standard. The chromatographic analysis was achieved on a Shimadzu LC 20A HPLC system equipped with a Zorbax Eclipse XDB C18 column and an isocratic mobile phase consisting of 20 mm KH2PO4 (pH 2.5) and methanol (95:5, v/v) run at a flow rate of 1 mL/min. The UV detection wavelength was set at 230 nm. The method exhibited good linearity (R2 > 0.999) over the assayed concentration range (0.1–10 μg/mL) and demonstrated good intra‐ and inter‐day precision and accuracy (relative standard deviations and the deviation from predicted values were <15%). This method was also successfully applied for studying the potential effect of ketogenic diet on the pharmacokinetics of l ‐Dopa in Parkinson's participants. Our data analysis indicates that ketogenic diet does not significantly affect the pharmacokinetics of l ‐Dopa.  相似文献   

11.
A rapid and sensitive LC–MS/MS method with good accuracy and precision was developed and validated for the pharmacokinetic study of quercetin‐3‐O‐β‐d ‐glucopyranosyl‐7‐O‐β‐d ‐gentiobioside (QGG) in Sprague–Dawley rats. Plasma samples were simply precipitated by methanol and then analyzed by LC–MS/MS. A Venusil® ASB C18 column (2.1 × 50 mm, i.d. 5 μm) was used for separation, with methanol–water (50:50, v/v) as the mobile phase at a flow rate of 300 μL/min. The optimized mass transition ion‐pairs (m/z) for quantitation were 787.3/301.3 for QGG, and 725.3/293.3 for internal standard. The linear range was 7.32–1830 ng/mL with an average correlation coefficient of 0.9992, and the limit of quantification was 7.32 ng/mL. The intra‐ and inter‐day precision and accuracy were less than ±15%. At low, medium and high quality control concentrations, the recovery and matrix effect of the analyte and IS were in the range of 89.06–92.43 and 88.58–97.62%, respectively. The method was applied for the pharmacokinetic study of QGG in Sprague–Dawley rats. Copyright © 2016 John Wiley & Sons, Ltd.  相似文献   

12.
Levo ‐tetrahydropalmatine (l‐ THP) is an alkaloid isolated from Chinese medicinal herbs of the Corydalis and Stephania genera. It has been used in China for more than 40 years mainly as an analgesic with sedative/hypnotic effects. Despite its extensive use, its metabolism has not been quantitatively studied, nor there a sensitive reliable bioanalytical method for its quantification simultaneously with its metabolites. As such, the objective of this study was to develop and validate a sensitive and selective HPLC method for simultaneous quantification of l‐ THP and its desmethyl metabolites l‐ corydalmine (l‐ CD) and l‐ corypalmine (l‐ CP) in rat plasma and brain tissues. Rat plasma and brain samples were processed by liquid–liquid extraction using ethyl acetate. Chromatographic separation was achieved on a reversed‐phase Symmetry® C18 column (4.6 × 150 mm, 5 μm) at 25°C. The mobile phase consisted of acetonitrile–methanol–10 mm ammonium phosphate (pH 3) (10:30:60, v /v) and was used at a flow rate of 0.8 mL/min. The column eluent was monitored at excitation and emission wavelengths of 230 and 315 nm, respectively. The calibration curves were linear over the concentration range of 1–10,000 ng/mL. The intra‐ and interday reproducibility studies demonstrated accuracy and precision within the acceptance criteria of bioanalytical guidelines. The validated HPLC method was successfully applied to analyze samples from a pharmacokinetic study of l‐ THP in rats. Taken together, the developed method can be applied for bioanalysis of l‐ THP and its metabolites in rodents and potentially can be transferred for bioanalysis of human samples.  相似文献   

13.
In this work, a [Cu(mal)(bpy)]?H2O (mal, l ‐(?)‐malic acid; bpy, 4,4′‐bipyridyl) homochiral metal‐organic frameworks (MOFs) was synthesized and used for modifying the inner walls of capillary columns by utilizing amido bonds to form covalent links between the MOFs particles and capillary inner wall. The synthesized [Cu(mal)(bpy)]?H2O and MOFs‐modified capillary column were characterized by X‐ray diffraction, thermogravimetric analysis, particle size distribution analysis, nitrogen absorption characterization, FTIR spectroscopy, SEM, and energy‐dispersive X‐ray spectroscopy (EDX). The MOFs‐modified capillary column was used for the stereoisomer separation of some drugs. The LODs and LOQs of six analytes were 0.1 and 0.25 μg/mL, respectively. The linear range was 0.25–250 μg/mL for ephedrine, 0.25–250 μg/mL for pseudoephedrine, 0.25–180 μg/mL for d ‐penicillamine, 0.25–120 μg/mL for l ‐penicillamine, 0.25–180 μg/mL for d ‐phenylalanine, and 0.25–160 μg/mL for l ‐phenylalanine, all with R2 > 0.999. Finally, the MOFs‐modified capillary column was applied for the analysis of active ingredients in a real sample of the traditional Chinese medicine ephedra.  相似文献   

14.
d ‐Lactic acid in urine originates mainly from bacterial production in the intestinal tract. Increased d ‐lactate excretion as observed in patients affected by short bowel syndrome or necrotizing enterocolitis reflects d ‐lactic overproduction. Therefore, there is a need for a reliable and sensitive method able to detect d ‐lactic acid even at subclinical elevation levels. A new and highly sensitive method for the simultaneous determination of l ‐ and d ‐lactic acid by a two‐step procedure has been developed. This method is based on the concentration of lactic acid enantiomers from urine by supported liquid extraction followed by high‐performance liquid chromatography–tandem mass spectrometry. The separation was achieved by the use of an Astec Chirobiotic? R chiral column under isocratic conditions. The calibration curves were linear over the ranges of 2–400 and 0.5–100 µmol/L respectively for l ‐ and d ‐lactic acid. The limit of detection of d ‐lactic acid was 0.125 µmol/L and its limit of quantification was 0.5 µmol/L. The overall accuracy and precision were well within 10% of the nominal values. The developed method is suitable for production of reference values in children and could be applied for accurate routine analysis. Copyright © 2011 John Wiley & Sons, Ltd.  相似文献   

15.
Racemates of hydrophobic amino acids with linear side chains are known to undergo a unique series of solid‐state phase transitions that involve sliding of molecular bilayers upon heating or cooling. Recently, this behaviour was shown to extend also to quasiracemates of two different amino acids with opposite handedness [Görbitz & Karen (2015). J. Phys. Chem. B, 119 , 4975–4984]. Previous investigations are here extended to an l ‐2‐aminobutyric acid–d ‐methionine (1/1) co‐crystal, C4H9NO2·C5H11NO2S. The significant difference in size between the –CH2CH3 and –CH2CH2SCH3 side chains leads to extensive disorder at room temperature, which is essentially resolved after a phase transition at 229 K to an unprecedented triclinic form where all four d ‐methionine molecules in the asymmetric unit have different side‐chain conformations and all three side‐chain rotamers are used for the four partner l ‐2‐aminobutyric acid molecules.  相似文献   

16.
This paper extends the research of the utilization of borate coordination complexes in chiral separation by counter‐current chromatography (CCC). Racemic propafenone was successfully enantioseparated by CCC with di‐n‐butyl l ‐tartrate combined with boric acid as the chiral selector. The two‐phase solvent system was composed of chloroform/ 0.05 mol/L acetate buffer pH 3.4 containing 0.10 mol/L boric acid (1:1, v/v), in which 0.10 mol/L di‐n‐butyl l ‐tartrate was added in the organic phase. The influence of factors in the enantioseparation of propafenone were investigated and optimized. A total of 92 mg of racemic propafenone was completely enantioseparated using high‐speed CCC in a single run, yielding 40–42 mg of (R)‐ and (S)‐propafenone enantiomers with an HPLC purity over 90–95%. The recovery for propafenone enantiomers from fractions of CCC was in the range of 85–90%.  相似文献   

17.
A sensitive and reliable ultra‐high‐performance liquid chromatography with tandem mass spectrometry (UHPLC–MS/MS) method was developed and validated for simultaneous determination of l ‐tetrahydropalmatine (l ‐THP) and its active metabolites l ‐isocorypalmine (l ‐ICP) and L ‐corydalmine (l ‐CD) in rat plasma. The analytes were extracted by liquid–liquid extraction and separated on a Bonshell ASB C18 column (2.1 × 100 mm; 2.7 μm; Agela) using acetonitrile–formic acid aqueous as mobile phase at a flow rate of 0.2 mL/min in gradient mode. The method was validated over the concentration range of 4.00–2500 ng/mL for l ‐THP, 0.400–250 ng/mL for l ‐ICP and 1.00–625 ng/mL for l ‐CD. Intra‐ and inter‐day accuracy and precision were within the acceptable limits of <15% at all concentrations. Correlation coefficients (r ) for the calibration curves were >0.99 for all analytes. The quantitative method was successfully applied for simultaneous determination of l ‐THP and its active metabolites in a pharmacokinetic study after oral administration with l ‐THP at a dose of 15 mg/kg to rats.  相似文献   

18.
Separation of racemic mixture of (RS)‐bupropion, (RS)‐baclofen and (RS)‐etodolac, commonly marketed racemic drugs, has been achieved by modifying the conventional ligand exchange approach. The Cu(II) complexes were first prepared with a few l ‐amino acids, namely, l ‐proline, l ‐histidine, l ‐phenylalanine and l ‐tryptophan, and to these was introduced a mixture of the enantiomer pair of (RS)‐bupropion, or (RS)‐baclofen or (RS)‐etodolac. As a result, formation of a pair of diastereomeric complexes occurred by ‘chiral ligand exchange’ via the competition between the chelating l ‐amino acid and each of the two enantiomers from a given pair. The diastereomeric mixture formed in the pre‐column process was loaded onto HPLC column. Thus, both the phases during chromatographic separation process were achiral (i.e. neither the stationary phase had any chiral structural feature of its own nor did the mobile phase have any chiral additive). Separation of diastereomers was successful using a C18 column and a binary mixture of MeCN and TEAP buffer of pH 4.0 (60:40, v/v) as mobile phase at a flow rate of 1 mL/min and UV detection at 230 nm for (RS)‐Bup, 220 nm for (RS)‐Bac and 223 nm for (RS)‐Etd. Baseline separation of the two enantiomers was obtained with a resolution of 6.63 in <15 min. Copyright © 2016 John Wiley & Sons, Ltd.  相似文献   

19.
The Rose Bengal‐sensitized photooxidations of the dipeptides l ‐tryptophyl‐l ‐phenylalanine (Trp‐Phe), l ‐tryptophyl‐l ‐tyrosine (Trp‐Tyr) and l ‐tryptophyl‐l ‐tryptophan (Trp‐Trp) have been studied in pH 7 water solution using static photolysis and time‐resolved methods. Kinetic results indicate that the tryptophan (Trp) moiety interacts with singlet molecular oxygen (O2(1Δg)) both through chemical reaction and through physical quenching, and that the photooxidations can be compared with those of equimolecular mixtures of the corresponding free amino acids, with minimum, if any, influence of the peptide bond on the chemical reaction. This is not a common behavior in other di‐ and polypeptides of photooxidizable amino acids. The ratio between chemical (kr) and overall (kt) rate constants for the interaction O2(1Δg)‐dipeptide indicates that Trp‐Phe and Trp‐Trp are good candidates to suffer photodynamic action, with krlkt values of 0.72 and 0.60, respectively (0.65 for free Trp). In the case of Trp‐Tyr, a lower krlkt value (0.18) has been found, likely as a result of the high component of physical deactivation of O2(1Δg) by the tyrosine moiety. The analysis of the photooxidation products shows that the main target for O2(1Δg) attack is the Trp group and suggests a much lower accumulation of kynurenine‐type products, as compared with free Trp. This is possibly because of the occurrence of another accepted alternative pathway of oxidation that gives rise to 3a‐oxidized hydrogenated pyrrolo[2,3‐b]indoles.  相似文献   

20.
The identification of impurities in l‐ carnitine by mass spectrometry is difficult because derivative reagents or ion pair reagents are usually used to separate and increase the retention of l‐ carnitine on the reversed‐phase column. In this study, four impurities including 3‐chloro‐2‐hydroxy‐N,N,N‐trimethylpropan‐1‐aminium, 3‐cyano‐2‐hydroxy‐N,N,N‐trimethylpropan‐1‐aminium, 3‐carboxy‐N,N,N‐trimethylprop‐2‐en‐1‐aminium, and 4‐chloro‐2,3,4‐trihydroxy‐N,N,N‐trimethylbutan‐1‐aminium were identified in l‐ carnitine and its tablets by using two‐dimensional column‐switching high‐performance liquid chromatography coupled with linear ion trap mass spectrometry. The first column was a C8 column at a flow rate of 0.15 mL/min; the detection wavelength was 220 nm. The second column was an Acclaim Q1 column using a gradient elution program with aqueous 30 mM ammonium acetate (pH 5.0) and acetonitrile as the mobile phase at a flow rate of 0.5 mL/min. The mass fragmentation patterns and structural assignments of impurities were studied, and the quantitative validation of three impurities was further investigated. The linearity (r 2) was found to be >0.99, with ranges from 0.2 to 50 ng/mL and 0.1 to 10 ng/mL. The method was used successfully for determination of impurities in five samples of l‐ carnitine and tablets.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号