首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 482 毫秒
1.
A sub-micrometer thin-layer DNA modified carbon fiber microcylinder electrode was prepared by electrodeposition of ct-DNA at 1.5V (vs. Ag/AgCl). The voltammetric behavior of dopamine (3-hydroxytyramine) was investigated at the modified electrode. It was found that the modified electrode exhibits a highly electrocatalytic activity toward dopamine oxidation. Differential pulse voltammetry was used for determination of dopamine in pH 7.4 phosphate buffer solution. A linear response of the peak current versus the concentration was found in the range of 4×10–6 to 10–4molL–1 at 10–4molL–1 AA (ascorbic acid) coexistence (R=0.9959) and the range of 6×10–5 to 10–3molL–1 at 10–3molL–1 AA (R=0.9960). The presence of a high concentration of ascorbic acid did not interfere with the determination. The proposed method exhibited good recovery and reproducibility. This method can be applied to the detection of DA in real samples.  相似文献   

2.
The polarographic reduction and catalytic behavior of lovastatin are studied by polarography and cyclic voltammetry. The reduction wave of lovastatin appears at ca. –1.49V (vs. SCE) in 0.16molL–1 Na2B4O7–KH2PO4 (pH=7.4) supporting electrolyte containing 20% ethanol. It is ascribed to a 2e, 2H+ addition to the carbonyl group on lactone ring. If H2O2 is present, the reduction wave is catalyzed to produce a polarographic catalytic wave. Based on the catalytic wave, a novel method for the determination of lovastatin is proposed. A rectilinear calibration curve of the catalytic wave was obtained for lovastatin concentration in the range 1.5×10–8 to 1.0×10–6molL–1. The peak current of the catalytic wave is ca. 12 times higher than that of the corresponding reduction wave. The detection limit is 8.0×10–9molL–1. The proposed method is simpler, faster and more sensitive than the known methods for lovastatin analysis, and can be applied to the direct determination of lovastatin in pharmaceuticals, urine and serum without preliminary separation.  相似文献   

3.
A spectrophotometric method for the selective determination of Al(III) in the presence of Be and Ln (lanthanide) cations is proposed. It is based on the selective reaction of SXO (Semi-Xylenol Orange) with Al(III) at pH 2.6. The presence of 8%v/v of 1,2-ethanediol serves to stabilize the chelate formed by heating at 100°C for 5min. 0.5mg each of Be(II), Ce(III), La(III), 4mg of Mn(II), 1.2mg of Pb(II), 1mg of Tl(I), 40mg each of Ca(II) and Mg(II) and 1.9mg of sodium dihydrogen phosphate are tolerable. A ligand buffer of HEDTA-Pb is incorporated to further enhance the selectivity of the color reaction. Under the specified conditions SXO reacts with Al(III) to form a 1:1 chelate. Its molar absorptivity at 526nm was found to be 3.3×104Lmol–1cm–1. The linear regression equation for 2–20µg of Al(III) is A=0.04458C+0.0112 (where C stands for the concentration of Al(III), µg per 25mL) and correlation coefficient =0.9988. The RSD at the level of 10µg (n=10) and LOQ were found to be 3.5% and 2µg, respectively.  相似文献   

4.
A simple and novel electrogenerated chemiluminescence (ECL) method for the determination of sulfite has been developed based on the energy transfer ECL process. It was found that a weak ECL signal of sulfite was electrochemically generated on a platinum electrode in neutral aqueous solution. The signal was strongly enhanced by rhodamine B as an energy receptor and further enhanced by the neutral surfactant Tween 80. In 0.10M phosphate buffer solution (pH=7.5) containing 2.0×10–6gmL–1 rhodamine B and 0.4% (v/v) Tween 80, the ECL response to the concentration of sulfite at a potential of 0.82V was linear over a range of 1.0×10–7gmL–1 to 8.0×10–6gmL–1, and the detection limit was 5×10–8gmL–1. The relative standard deviation (n=11, 1.0×10–6gmL–1) was 3.8%. The proposed method has been successfully applied to the determination of sulfite in pharmaceutical injections and white sugar samples.  相似文献   

5.
This paper presents a new simple and rapid procedure for the preconcentration and determination of platinum. It is based on the adsorption of the metal ion and preconcentration on a micro-column (3cm×3mm) placed in the injection valve of a flow injection (FI) manifold and packed with 1,5-bis[(2-pyridyl)-3-sulphophenyl-methylene]thiocarbonohydrazide (PSTH) immobilised on an anion-exchange resin (Dowex 1X8-200). The metal was eluted from the column using a solution of 2M HNO3. Various parameters and chemical variables affecting the preconcentration and determination of this metal by ICP-AES were evaluated. Five variables (sample flow rate, eluent flow rate, nebulizer flow rate, buffer concentration and mixing coil length) were considered as factors in the optimisation process. Interactions between analytical factors, and their optimal levels were investigated using two level factorial and central matrix designs. The optimum conditions established were applied to the determination of platinum by flow injection inductively coupled plasma atomic emission spectrometry (FI-ICP-AES). The method has a linear calibration range of 25 to at least 200ngmL–1 with a detection limit of 7.4ngmL–1 (S/N=3) and a throughput of 10 samples h–1 using 5min. preconcentration time. The precision of the method (RSD) was 3.06% ngmL–1 at the 50ngmL–1 level of Pt(IV) and 2.93% at the 150ngmL–1 level. The accuracy of the method was examined by determining the analyte content in spiked waters and by analysing an automobile catalyst standard reference material. The results show good agreement with the certified value and sufficiently high recoveries.  相似文献   

6.
Summary. The dissociation constants of the two oxime groups of 1,1-bis(pyridinium-4-aldoxime)trimethylene dibromide (TMB-4) were determined using spectrophotometric data. Two numerical methods were applied to treat the overlapping equilibria. The results obtained by both agreed with each other and their mean values at 25°C corrected for the ionic strength of 0.05moldm–3 are pKa1=7.49±0.11 and pKa2=8.96±0.09. These values were discussed in terms of the pKas of 1,1-bis(pyridinium-4-aldoxime)oxydimethylene dichloride (Toxogonin), a similar dioxime, which were derived by extrapolation of literature data.  相似文献   

7.
2,3-Dihydroxypyridine loaded (via –N=N–linker) Amberlite XAD-2 (AXAD-2-DHP) was prepared and characterized by elemental analyses, TGA and FT-IR spectra. It (1g packed in a column of 1cm diameter; surface area 135.5m2g–1) was found to be an effective solid phase sorbent for enriching Zn2+, Mn2+, Ni2+, Pb2+, Cd2+, Cu2+, Fe3+ and Co2+ at pH 3.5 to 7.0 using flow rates between 1.0–5.0mLmin–1. For desorption (recovery 97.0–99.8%) of the metal ions, 8 to 10mL of 2.0molL–1 HCl or 1.5molL–1 HNO3 at a flow rate of between 2.0 and 4.0mLmin–1 were found most suitable. The t1/2 (time for 50% sorption) is between 2 and 10min when a 50mL solution (containing a total amount of metal of 2mg) was equilibrated with 0.5g of resin. Sorption of all metal ions except Pb2+ follows the Langmuir model, whereas for Pb the data fits with the Freundlich model. The sorption capacity is between 60.7 (for Cd) and 406.7 (for Cu) µmolg–1. The resin can withstand an acid concentration of 6molL–1 and can be reused for thirty cycles of sorption–desorption. The preconcentration factor varies between 100 and 300. For Cd, Ni and Cu the sorption capacity of 2,3-dihydroxypyridine loaded cellulose is lower than that of the present resin. The tolerance limits of electrolytes, humic acid, complexing agents, Ca2+ and Mg2+ in the enrichment of all metal ions are reported. The limits of detection are 3.88, 5.37, 8.72, 13.88, 4.71, 1.24, 0.59 and 0.30µgL–1 for Zn2+, Mn2+, Ni2+, Pb2+, Cd2+, Cu2+, Fe3+ and Co2+, respectively. The calibration curves for flame AAS determination were linear in the ranges 0.018–1.0, 0.067–5.0, 0.2–5.0, 0.9–20, 0.028–2.0, 0.077–5.0, 0.19–10 and 0.1–3.5µgmL–1, respectively. All the eight metal ions in river and synthetic water samples, Co in vitamin tablets and Zn in milk samples have been quantitatively enriched with Amberlite XAD-2-DHP and determined by flame atomic absorption spectrometry.  相似文献   

8.
A -mercaptopropionic acid (MPA) self-assembled monolayer modified electrode (MPA/SAM/Au) on a gold electrode has been fabricated. The characterization of the MPA/SAM/Au was investigated using attenuated total reflection-fourier transform infrared (ATR-FTIR) and A.C. impedance. The electrochemical behaviors of p-aminophenol (p-AP) were studied at the MPA/SAM/Au by cyclic voltammetry and semi-derivative voltammetry (SDV) in BR buffer solution. The modified electrode shows excellent electrocatalytic activity for the redox of p-AP and accelerates the electron transfer rate. The diffusion coefficient (D) is 4.55×10–6cm2s–1. The oxidative peak current increases linearly with the concentration of p-AP in the range of 4.0×10–88×10–6molL–1 and 1.0×10–52×10–4molL–1 by square wave voltammetry response, respectively. The detection limit (three times the signal blank/slope) is up to 1.2×10–8molL–1. The modified electrode is able to eliminate the interference of p-benzenediol, o-benzenediol and o-AP at a 40-, 90- or 70-fold concentration of p-AP, and it has been satisfactorily used for the determination of the real sample.  相似文献   

9.
A simple commercial graphite pencil electrode (GPE) was utilized for monitoring caffeine using the square-wave anodic stripping voltammetry (SWASV) method. This method was applied to determine the caffeine levels in several tea samples, which yielded a relative error of 1% in the concentrations. Caffeine was deposited at 0.0V (vs. Ag/AgCl), then reduced at +1.40V to strip it on the GPE. Optimal experimental conditions for the analysis were found to be as follows: pH value of 9 for the medium; deposition potential of 0.0V; deposition time of 120s; SW frequency of 25Hz; SW amplitude of 45mV, and step potential of 6mV. Given these optimum conditions, a linear range was observed within the concentration of 0500mgL–1. At caffeine concentrations of 50.0, 250.0, and 500.0mgL–1, the relative standard deviations in measured concentrations (n=12) were 0.19, 0.09, and 0.11%, respectively. The detection limit was found to be 9.2mgL–1, which is comparable with the result obtained using a carbon paste electrode, equivalent to 8.2mgL–1.  相似文献   

10.
A new flow injection catalytic spectrophotometric method for on-line preconcentration and determination of total iron in natural water is described. The method is based on a combination of iron-catalyzed oxidation of diaminoditolyl by potassium bromate and the use of on-line preconcentration of iron onto 8-hydroxy-quinoline immobilized on silica gel. The corresponding calibration graph is linear over the range of 2.0–110ngmL–1 for Fe(III) using a time-based technique for 5min preconcentration. The relative standard deviation of 11 measurements of 60ngmL–1 Fe(III) was 0.67%. The method was applied to the determination of iron in natural water. The results obtained by the proposed method were compared with those obtained by ICP-AES. The t-test showed no significant differences between the two methods at a confidence level of 95%.  相似文献   

11.
A sensitive derivative adsorption chronopotentiometric method was developed to determine trace amounts of Fe3+. The influence of preconcentration time, pH of solution and constant reducing current of the peak height is discussed. The detection limit and the linear range are 5.0×10–10 and 2.0×10–93.0×10–6molL–1, respectively. The method was used to determine trace Fe3+ in KH2PO4 crystals (KDP).  相似文献   

12.
A new method for the simultaneous determination of heavy metal ions in Chinese herbal medicine by microwave digestion and reversed-phase high-performance liquid chromatography (RP-HPLC) has been developed. The Chinese herbal medicine samples were digested by microwave digestion. Lead, cadmium, mercury, nickel, copper, zinc, and tin ions in the digested samples were pre-column derivatized with tetra-(4-chlorophenyl)-porphyrin (T4-CPP) to form the colored chelates which were then enriched by solid phase extraction with C18 cartridge and eluted from the cartridge with tetrahydrofuran (THF). The chelates were separated on a Waters Xterra RP18 column by gradient elution with methanol (containing 0.05molL–1 pyrrolidine-acetic acid buffer salt, pH=10.0) and THF (containing 0.05molL–1 pyrrolidine-acetic acid buffer salt, pH=10.0) as mobile phase at a flow rate of 0.5mLmin–1 and detected with a photodiode array detector in the range of 350–600nm. In the original samples the detection limits of lead, cadmium, mercury, nickel, copper, zinc and tin are 4ngL–1, 3ngL–1, 6ngL–1, 5ngL–1, 2ngL–1, 6ngL–1, and 4ngL–1, respectively. This method was applied to the determination of lead, cadmium, mercury, nickel, copper, zinc and tin in Chinese herbal medicine samples with good results.  相似文献   

13.
This study presents a PVC membrane based on 5,11,17,23,29,35-Hexakis-t-octyl-37,38,39,40,41,42-hexakis(N-phenylthiocarbamoylmethoxy)calix[6]arene which is used as an electroactive substance. The electrode reveals a Nernstian response for Ni2+ over a wide pH range with a slope of linear portion (5×10–6–1×10–2M, R=0.988) of 29.75±0.2mV·decade–1 at 25°C. The electrodes sensitivity is enhanced upon the introduction of sodium tetraphenylborate into the membrane as a negatively charged lipophilic additive. The selectivity coefficients of various interfering ions were determined using the fixed interference method (FIM). The membrane reveals good selectivity for nickel ions over the other metal ions investigated. The lifetime of this electrode is about one month. This electrode has been applied to the determination of nickel ions in wastewater from the electroplating industry.  相似文献   

14.
A single-wall carbon nanotubes (SWNT) film coated glassy carbon electrode (GCE) was fabricated for the direct determination of 4-nitrophenol (4-NP). The electrochemical behaviors of 4-NP at the SWNT-film coated GCE were examined. In 0.1M phosphate buffer with a pH of 5.0, 4-NP yields a very sensitive and well-defined reduction peak at the SWNT-modified GCE. It is found that the SWNT film exhibits obvious electrocatalytic activity towards the reduction of 4-NP since it not only increases the reduction peak current but also lowers the reduction overpotential. Based on this, an electrochemical method was proposed for the direct determination of 4-NP. The reduction peak current varies linearly with the concentration of 4-NP ranging from 1×10–8 to 5×10–6M, and the detection limit is 2.5×10–9M after 3min of open-circuit accumulation. The relative standard deviation at 2×10–7M 4-NP was about 6% (n=10), suggesting excellent reproducibility. This new method was successfully employed to determine 4-NP in several lake water samples.  相似文献   

15.
Thallium in natural water samples was determined by electrothermal atomic absorption spectrometry after 1000-fold enrichment by mini solid-phase extraction from a 100-mL sample solution. A Tl-pyrrolidine-1-carbodithioate complex formed in a sample solution of pH 1.6 was extracted on fine particles of a cellulose nitrate resin dispersed in the sample solution. The cellulose nitrate resin was then collected on a membrane filter (25mmø) by filtration under suction using a glass funnel with an effective filtration area of 0.64cm2. As a result, a circular thin layer of the resin phase with a diameter of 9mm was obtained. Then the resin phase was carved out by an acrylate resin puncher with a 10-mmø hole to put it into a sample cup containing 100µL of 10mM HNO3 containing 0.5mM NaCl. The resin phase was suspended in the solution by ultrasonication. 1000-fold enrichment was thus attained within 15min, and the suspension was delivered to electrothermal atomic absorption spectrometry. The linear calibration graph was obtained in the range of 0–4ng of Tl in 100mL of a sample solution. The detection limit obtained by 3 method was 0.19ng. The proposed method was applied to the determination of Tl in natural water samples. The results showed the concentration of Tl in seawater was 12.1±1.8pgmL–1 for the calibration graph method and 12.6±1.4pgmL–1 for the standard addition method. A snowmelt sample contained 20.7±1.0pgmL–1 of Tl.  相似文献   

16.
A simple preconcentration method has been developed for the determination of trace amounts of rare earth elements (La, Eu, and Yb) in natural water samples by inductively coupled plasma atomic emission spectrometry (ICP-AES). Preconcentration of La, Eu, and Yb was achieved by sorption of their 1-phenyl-3-methyl-4-benzoylpyrazol-5-one (PMBP) complexes on a silica gel column at pH 5 and then eluting with 1.0molL–1 HNO3. For the preconcentration of 100mL of aqueous solution, an enrichment of 100 was obtained for all analytes, and the detection limits for La, Eu and Yb were 82, 34 and 45ngL–1, respectively. The accuracy of this method was demonstrated by analyzing a standard reference material. The method has been successfully applied to the determination of La, Eu and Yb in lake water and synthetic seawater.  相似文献   

17.
The fabrication and electrochemical characteristics of a penicillamine (PCA) self-assembled monolayer modified gold electrode were investigated. The self-assembled electrode shows obvious electrocatalytic activity for the oxidation of epinephrine (EP). In phosphate buffer (pH 7.73), a sensitive oxidation peak was observed at 0.190V with the PCA modified Au electrode. The peak current is proportional to the concentration of EP in the range of 2.0×10–56.0×10–4molL–1 and 5.0×10–6 2.0×10–4molL–1 for cyclic voltammetry (CV) and differential pulse voltammetry (DPV) with the detection limits of 1.8×10–7 and 1.3×10–7molL–1, respectively. The possible reaction mechanism is also discussed. The PCA self-assembled monolayer modified gold electrode is highly stable and can be applied to the determination of EP in practical injection samples. Application is simple, rapid and produces accurate results.  相似文献   

18.
A new ligand, 1-(2-furanthiocarbo)-3-thiosemicarbazide (H2ftsc), prepared from thiosemicarbazide and carboxymethyl-2-furandithioate, forms complexes [Mn(ftsc)(H2O)2], [Pd(ftsc)] · 2H2O, [M(Hftsc)(acac)2] (M=CoIII or CrIII), [M(Hftsc)2(acac)] (M=MnIII or FeIII) and [Zn(Hftsc)2] · 2H2O, which were characterized by elemental analyses, magnetic susceptibility, i.r., electronic and n.m.r. spectral data. The Mössbauer spectra of [Fe(Hftsc)2(acac)] at 298K and 80K suggest the presence of high-spin iron(III) with an S=5/2 state. In vivo and in vitro antitumour activity of the ligand and the complexes have been screened towards several tumour cell-lines.  相似文献   

19.
In this study, a syringe-connected minicolumn resin was used for the separation and enrichment of cadmium, copper, nickel and zinc prior to their determination by flame atomic absorption spectrometry. The proposed technique was compared with classical batch and column techniques in terms of rapidness, simplicity, enrichment and risk of contamination. The minicolumn was filled with Chromosorb-103 resin and connected to a syringe. If the samples were treated with ammonium pyrrolidine dithiocarbamate or 8-hydroxyquinoline, the analytes were quantitatively retained at pH2 and pH5 on the resin, respectively. On the other hand, if no chelating agent was added, the analytes were quantitatively retained at pH10. The analytes retained by the resin were quantitatively eluted by drawing and discharging nitric acid in acetone. The analytes in spiked river-water samples and in certified standard reference Bovine-Liver (NIST SRM 1577 b) were quantitatively (94%) recovered. The relative standard deviations for the determinations were found to be 1.0–10%.  相似文献   

20.
    
–20°C÷+20°C . , , . lg k1=(10,10±0,02) – (930±400)/RT M–1 –1.
The electron exchange between benzosemiquinone and benzoquinone has been studied by NMR spectroscopy at /–20/–/+20/°C in DMF. The broadening of the proton resonance lines of benzoquinone in the presence of benzosemiquinone corresponds to the case of rapid exchange with a rate constant of lg k1=/10.10±0.02/–/930±400//RT M–1s–1.
  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号