首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Xu S  Tu G  Peng B  Han X 《Analytica chimica acta》2006,570(2):151-157
A novel strategy to construct a sensitive mediatorless sensor of H2O2 was described. At first, a cleaned gold electrode was immersed in thiol-functionalized poly(styrene-co-acrylic acid) (St-co-AA) nanosphere latex prepared by emulsifier-free emulsion polymerization St with AA and function with dithioglycol to assemble the nanospheres, then gold nanoparticles were chemisorbed onto the thiol groups and formed monolayers on the surface of poly(St-co-AA) nanospheres. Finally, horseradish peroxidase (HRP) was immobilized on the surface of the gold nanoparticles. The sensor displayed an excellent electrocatalytical response to reduction of H2O2 without the aid of an electron mediator. The biosensor showed a linear range of 8.0 μmol L−1–7.0 mmol L−1 with a detection limit of 4.0 μmol L−1. The biosensor retained more than 97.8% of its original activity after 60 days’ storage. Moreover, the studied biosensor exhibited good current reproducibility and good fabrication reproducibility.  相似文献   

2.
Jiao K  Zhang S  Wei L  Liu C  Zhang C  Zhang Z  Liu J  Wei P 《Talanta》1998,47(5):47-1137
o-Dianisidine (ODA)-H2O2-horseradish peroxidase (HRP) voltammetric enzyme-linked immunoassay system has firstly been used for the detection of tobacco mosaic virus (TMV). HRP catalyzes strongly the oxidation reaction of ODA by H2O2, the product of which produces a sensitive second order derivative linear sweep voltammetric peak at potential of −0.56 V (versus SCE) in Britton–Robinson (BR) buffer. HRP activity has been measured with this voltammetric peak and TMV detected through immunoreaction. The detection limit for HRP is 9.25×10-7 mU l−1 and the linear range is 2.5×10−6–5.0×10−4 mU l−1. The detection limit for the clarified TMV is 0.25 ng ml−1 and the highest dilution ratio detected for the infected leaf sap is 1:8×105. The sensitivity for TMV detection with this method is higher than that with the enzyme-linked immunosorbent spectrophotometric assay (ELISA) using ODA-H2O2-HRP system. The processes of the enzyme-catalyzed reaction and the electro-reduction of the product of the enzyme-catalyzed reaction have been described.  相似文献   

3.
Commercial non-food packaging materials of four different matrices (paper, low density polyethylene (LDPE), polyethylene-polypropylene (PE-PP) and high density polyethylene (HDPE)) were examined for the content of Cr, Ni, Cu, Zn, As, Mo, Cd, Sb, Ba, Hg, Tl, Pb and U. The examined samples (0.17–0.35 g) were digested in HNO3 and H2O2 (papers, LDPE and PE-PP) and in HNO3, H2SO4 and H2O2 (HDPE) using microwave assisted high pressure system. The inductively coupled plasma-time of flight-mass spectrometry (ICP-TOFMS) has been employed as the detection technique. All measurements were carried out using internal standardization. Yttrium and rhodium (50 ng g−1) were used as internal standards. The detection and quantification limits obtained were in the range of 0.005 ng g−1 (52Cr) to 0.51 ng g−1 (66Zn) and 0.015 μg g−1 (52Cr) to 2.02 μg g−1 (66Zn) of dry mass, respectively. The evaluated contents (mg kg−1) of particular elements in the examined materials were as follows: 0.22–219; <1.05–9.03; 1.25–112; <2.02–449; <0.98–<1.30; <0.36–2.06; <0.29–113; <0.22–44.1; <0.06–57.4; <0.66–<0.88; <0.08–0.24; <0.13–1222 and <0.08–0.44 for Cr, Ni, Cu, Zn, As, Mo, Cd, Sb, Ba, Hg, Tl, Pb and U, respectively.  相似文献   

4.
A direct immersion solid-phase microextraction coupled with gas chromatography-electron capture detection (SPME-GC-ECD) method was optimized and validated for the quantitative determination of 18 organochlorine pesticides in ground water. Ionic strength, stirring speed, adsorption and desorption time and pH were some of the parameters investigated in order to select the optimum conditions for SPME with a 50/30 DVB/CAR/PDMS fiber coating. The SPME-GC/ECD method showed good linear response below 10 ng L−1 with R2 values in the range of 0.9950–0.9997. The repeatability of the measurements were lower than 10%. Values of relative recoveries located within the acceptable range (80–120%). Limits of quantification (LOQ) from 4.5 × 10−3 to 1.5 ng L−1 were obtained. On average 8 organochlorines were found per sample, even so all the 18 organochlorines were quantified among them. Substances such as endrin ketone, γ-BHC and β-BHC were the pesticides determined in larger concentration (0.06–305 ng L−1), while methoxychlor and aldrin in smaller amounts (0.151–1.55 ng L−1). Measured levels of organochlorine pesticides were above the limits established by Brazilian regulations.  相似文献   

5.
A thin, gas-tight palladium (Pd) membrane was prepared by the counter-diffusion chemical vapor deposition (CVD) process employing palladium chloride (PdCl2) vapor and H2 as Pd precursors. A disk-shaped, two-layer porous ceramic membrane consisting of a fine-pore γ-Al2O3 top layer and a coarse-pore -Al2O3 substrate was used as Pd membrane support. A 0.5–1 μm thick metallic membrane was deposited in the γ-Al2O3 top layer very close to its surface, as verified by XRD and SEM with a backscattered electron detector. The most important parameters that affected the CVD process were reaction temperature, reactants concentrations and top layer quality. Deposition of Pd in the γ-Al2O3 top layer resulted in a 100- to 1000-fold reduction in He permeance of the porous substrate. The H2 permeation flux of these membranes was in the range 0.5–1.0 × 10−6 mol m−2 s−1 Pa−1 at 350–450°C. The H2 permeation data suggest that surface reaction steps are rate-limiting for H2 transport through such thin membranes in the temperature range studied.  相似文献   

6.
Thermal decomposition of mixed ligand thymine (2,4-dihydroxy-5-methylpyrimidine) complexes of divalent Ni(II) with aspartate, glutamate and ADA (N-2-acetamido)iminodiacetate dianions was monitored by TG, DTG and DTA analysis in static atmosphere of air. The decomposition course and steps of complexes [Ni(C5H6N2O2)(C4H5NO4)2−(H2O)2]·H2O, [Ni(C5H6N2O2)(C5H7NO4)2−(H2O)2]·H2O and [Ni(C5H6N2O2)(C6H8N2O5)2−(H2O)2]·1.5H2O were analyzed. The final decomposition products are found to be the corresponding metal oxides. The kinetic parameters namely, activation energy (E*), enthalpy (ΔH*), entropy (ΔS*) and free energy change of decomposition (ΔG*) are calculated from the TG curves using Coats–Redfern and Horowitz–Metzger equations. The stability order found for these complexes follows the trend aspartate > ADA > glutamate.  相似文献   

7.
Matos RC  Coelho EO  Souza CF  Guedes FA  Matos MA 《Talanta》2006,69(5):1208-1214
The importance of atmospheric hydrogen peroxide (H2O2) in the oxidation of SO2 and other compounds has been well established. A spectrophotometric method for the determination of hydrogen peroxide in rainwater is proposed. This method is based on selective oxidation of hydrogen peroxide using an on-line tubular reactor containing peroxidase immobilized on Amberlite IRA-743 resin. The hydrogen peroxide in the presence of phenol, 4-aminoantipyrine and peroxidase, produces a red compound (λ = 505 nm). Beer's law is obeyed in a concentration range of 1–100 μmol l−1 hydrogen peroxide with an excellent correlation coefficient (r = 0.9991), at pH 7.0, with a relative standard deviation (R.S.D.) <2%. The detection limit of the method is 0.7 μmol l−1 (4.8 ng of H2O2 in a 200 μl sample). Measurements of hydrogen peroxide in rain samples were carried out over the period from November 2003 to January 2005, in the central area of the Juiz de Fora city, Brazil. The concentration of H2O2 varied from values lower than the detection limit to 92.5 μmol l−1. The effects of the presence of nonseasalt (NSS) SO42−, NO3 and H+ in the concentration of hydrogen peroxide in the rainwater had been evaluated. The average concentrations of H2O2, NO3, NSS SO42− and SO42− are 23.4, 18.9, 7.9 and 10.3 μmol l−1, respectively. The pH values for 82% of the collected samples are greater than 5.0. The spectrophotometeric method developed in this work that uses enzyme immobilized on the resin ion-exchange compared with the amperometric method did not present any significant difference in the results.  相似文献   

8.
Ly SY 《Talanta》2008,74(5):1635-1641
The voltammetric assay of Cu(II) was investigated using a carbon nanotube electrode (CNE) and fluorine immobilized onto a carbon nanotube electrode (FCNE) in cyclic voltammetry (CV), square-wave (SW) stripping voltammetry, and chronoamperometry. Optimum SW conditions were attained at working ranges of 0.01–0.11 ng L−1 Cu(II) (11 points), and a relative standard deviation of 1.68% (RSD, n = 15) was observed at 10.0 μg L−1 Cu(II). Within a 200 s accumulation time, detection limit of 0.006 μg L−1 was attained. The life span of each electrode was more than 1 month. The sensor was applied to tap water, blood, and rat tail vascular (in vivo). It was found that the sensor could be used with an interface system in the assay of live cells and non-treated blood.  相似文献   

9.
Soh N  Nishiyama H  Asano Y  Imato T  Masadome T  Kurokawa Y 《Talanta》2004,64(5):1160-1168
A rapid and sensitive immunoassay for the determination of carp vitellogenin (Vg) is described. The method involves a sequential injection analysis (SIA) system equipped with a chemiluminescence detector and a samarium-cobalt magnet. An anti-Vg monoclonal antibody, immobilized on magnetic beads, was used as a solid support for the immunoassay. The introduction, trapping and release of the magnetic beads in the flow cell were controlled by a samarium-cobalt magnet and the flow of the carrier solution. The immunoassay was based on a sandwich immunoreaction of anti-Vg monoclonal antibody (primary antibody) on the magnetic beads, Vg, and the anti-Vg antibody labeled with horseradish peroxidase (HRP) (secondary antibody), and was based on a subsequent chemiluminescence reaction of HRP with hydrogen peroxide and p-iodophenol, in a luminol solution. The magnetic beads to which the primary antibody was immobilized were prepared by coupling the primary antibody with the magnetic beads after an agarose-layer on the surface of the magnetic beads was epoxidized. The primary antibody-immobilized magnetic beads were introduced, and trapped in the flow cell equipped with the samarium-cobalt magnet, a Vg sample solution, an HRP-labeled secondary antibody solution and the luminol solution were sequentially introduced into the flow cell based on an SIA programmed sequence. Chemiluminescence emission was monitored by means of a photomultiplier located at the upper side of the flow cell. The optimal incubation times both for the first and second immunoreactions were determined to be 20 min. A concave calibration curve was obtained between Vg concentration and chemiluminescence intensity when various concentrations of standard Vg samples (2–100 ng mL−1) were applied to the SIA system under optimal conditions. In spite of a narrow working range, the lower detection limit of the immunoassay was about 2 ng mL−1.  相似文献   

10.
Hong Dinh Duong  Jong Il Rhee   《Talanta》2007,73(5):899-905
In the present work, CdSe/ZnS core-shell quantum dots were synthesized and conjugated with enzymes, glucose oxidase (GOD) and horseradish peroxidase (HRP). The complex of enzyme-conjugated QDs was used as QD-FRET-based probes to sense glucose. The QDs were used as an electron donor, whereas GOD and HRP were used as acceptors for the oxidation/reduction reactions involved in oxidizing glucose to gluconic acid. Electron transfer between the redox enzymes and the electrochemical reduction of H2O2 (or O2) occurred rapidly, resulting in an increase of the turnover rate of the electron exchange between the substrates (e.g. glucose, H2O2 and O2) and the enzymes (GOD, HRP), as well as between the QDs and the enzymes. The transfer of non-radiative energy from the QDs to the enzymes resulted in the fluorescence quenching of the QDs, corresponding to the increase in the concentration of glucose. The linear detection ranges of glucose concentrations were 0–5.0 g/l (R = 0.992) for the volume ratios of 10/5/5, 0.2–5.0 g/l (R = 0.985) for the volume ratios of 10/5/3 and 1.0–5.0 g/l (R = 0.982) for the volume ratios of 10/5/0. Temperature (29–37 °C), pH (6–10) and some ions (NH4+, NO3, Na+, Cl) had no interference effect on the glucose measurement.  相似文献   

11.
The epoxidation of cyclopentene with hydrogen peroxide catalyzed by 12-heteropolyacids of molybdenum and tungsten (H3PMo12−nWnO40, n = 1–11), 12-tungstophosphoric acid and 12-molybdophosphoric acid combined with cetylpyridinium bromide as a phase transfer reagent was carried out in acetonitrile. Among 13 heteropolyacids investigated, catalyst of H3PMo6W6O40 showed the highest activity, giving a conversion of 60% and a selectivity of 95% in the epoxidation of cyclopentene. The fresh catalysts and the catalysts under reaction condition were characterized by UV–vis, FT-IR and 31P NMR spectroscopy, which has revealed that all of the molybdotungstophosphoric acids were degraded in the presence of hydrogen peroxide to form a considerable amount of phosphorus-containing species. The active species resulted from H3PMo6W6O40 are new kinds of phosphorus-containing species, which is different from {PO4[WO(O2)2]4}3−.  相似文献   

12.
Nanocrstalline pure anatase titania were prepared by sol–gel process at room temperature followed by ultrasonication (Ti–US). The photocatalytic activity of Ti–US has been evaluated by the degradation of textile dye, Methylene Blue in presence and absence of common inorganic salts (NO3, C2O42−, SO42−, citrate). It was observed that, in presence of anions, the degradation of the dye increases significantly. The influence of the presence of H2O2 on the degradation rate was studied. The dependence of photodegradation of the dye rates on various parameters such as dye concentration, photocatalyst concentration and pH were also investigated. The photodegradation rate follows first order kinetics. H2O2 and UV light have a negligible effect in absence of Ti–US catalyst. The relative photonic efficiency of the system is reported using phenol as a standard organic compound.  相似文献   

13.
Li YS  Ju X  Gao XF  Zhao YY  Wu YF 《Analytica chimica acta》2008,610(2):249-256
A new method for the determination of lactic acid based on the immobilization enzyme fluorescence capillary analysis (IE-FCA) was proposed. Lactic dehydrogenase (LDH) was immobilized on inner surface of a capillary with glutaraldehyde, and an immobilized enzyme lactate capillary bioreactor (IE-LCBR) was formed for the determination of lactic acid. After nicotinamide adenine dinucleotide (NAD+) is mixed with lactic acid solution, it was sucked into the IE-LCBR and was detected at λex 353 nm/λem 466 nm. Optimized conditions are as follows: the temperature is 38 °C; the reaction time is 15 min; the concentrations of Tris buffer (pH 8.8) and NAD+ are 0.1 mol L−1 and 4 mmol L−1, respectively; the concentration of LDH used for immobilization is 15 kU L−1. The concentration of lactic acid is directly proportional to the fluorescence intensity measured from 0.50 to 2.0 mmol L−1; and the analytical recovery of added lactic acid was 99–105%. The minimum detection limit of the method is 0.40 mmol L−1 and sensitivity of the IE-CBR is 4.6 F mmol−1 L−1 lactate. Its relative standard deviation (R.S.D.) is ≤2.0%. This IE-FCA method was employed for determination of lactate in milk drink.  相似文献   

14.
Li Liu  Jun-feng Song  Peng-fei Yu  Bin Cui 《Talanta》2007,71(5):1842-1848
A novel voltammetric method for the determination of β-d-glucose (GO) is proposed based on the reduction of Cu(II) ion in Cu(II)(NH3)42+–GO complex at lanthanum(III) hydroxide nanowires (LNWs) modified carbon paste electrode (LNWs/CPE). In 0.1 mol L−1 NH3·H2O–NH4Cl (pH 9.8) buffer containing 5.0 × 10−5 mol L−1 Cu(II) ion, the sensitive reduction peak of Cu(II)(NH3)42+–GO complex was observed at −0.17 V (versus, SCE), which was mainly ascribed to both the increase of efficient electrode surface and the selective coordination of La(III) in LNW to GO. The increment of peak current obtained by deducting the reduction peak current of the Cu(II) ion from that of the Cu(II)(NH3)42+–GO complex was rectilinear with GO concentration in the range of 8.0 × 10−7 to 2.0 × 10−5 mol L−1, with a detection limit of 3.5 × 10−7 mol L−1. A 500-fold of sucrose and amylam, 100-fold of ascorbic acid, 120-fold of uric acid as well as gluconic acid did not interfere with 1.0 × 10−5 mol L−1 GO determination.  相似文献   

15.
Wang J  Zhang C  Wang H  Yang F  Zhang X 《Talanta》2001,54(6):146-1193
A simple, fast chemiluminescence (CL) flow-injection method based on the reaction of luminol with H2O2 in the presence of a cationic surfactant (cyltrimethylammonium bromide, CTMAB) has been described for the direct determination of dichlorvos pesticide (DDVP). Under the optimal conditions, the CL intensity was linear to the DDVP concentration in the range of 0.02–3.1 μg ml−1 (r=0.9998, n=10). The relative standard deviation was 3.4% at 0.35 μg ml−1 (n=10), with a detection limit (3σ) of 0.008 μg ml−1 DDVP. The possible reaction mechanism was also discussed. This method has been successfully applied to the determination of trace DDVP residue in vegetable sample and results have been compared with that of the UV method.  相似文献   

16.
The compound [Zn(H2O)4]2[H2As6V15O42(H2O)]·2H2O (1) has been synthesized and characterized by elemental analysis, IR, ESR, magnetic measurement, third-order nonlinear property study and single crystal X-ray diffraction analysis. The compound 1 crystallizes in trigonal space group R3, a=b=12.0601(17) Å, c=33.970(7) Å, γ=120°, V=4278.8(12) Å3, Z=3 and R1(wR2)=0.0512 (0.1171). The crystal structure is constructed from [H2As6V15O42(H2O)]4− anions and [Zn(H2O)4]2+ cations linked through hydrogen bonds into a network. The [H2As6V15O42(H2O)]6− cluster consists of 15 VO5 square pyramids linked by three As2O5 handle-like units.  相似文献   

17.
This work presents chemical modeling of solubilities of metal sulfates in aqueous solutions of sulfuric acid at high temperatures. Calculations were compared with experimental solubility measurements of hematite (Fe2O3) in aqueous ternary and quaternary systems of H2SO4, MgSO4 and Al2(SO4)3 at high temperatures. A hybrid model of ion-association and electrolyte non-random two liquid (ENRTL) theory was employed to fit solubility data in three ternary systems H2SO4–MgSO4–H2O, H2SO4–Al2(SO4)3–H2O at 235–270 °C and H2SO4–Fe2(SO4)3–H2O at 150–270 °C. Employing the Aspen Plus™ property program, the electrolyte NRTL local composition model was used for calculating activity coefficients of the ions Al3+, Mg2+ Fe3+ and SO42−, HSO4, OH, H3O+, respectively, as well as molecular species. The solid phases were hydronium alunite (H3O)Al3(SO4)2(OH)6, hematite Fe2O3 and magnesium sulfate monohydrate (MgSO4)·H2O which were employed as constraint precipitation solids in calculating the metal sulfate solubilities. A correlation for the equilibrium constants of the association reactions of complex species versus temperature was implemented. Based on the maximum-likelihood principle, the binary interaction energy parameters for the ionic species as well as the coefficients for equilibrium constants of the reactions were obtained simultaneously using the solubility data of the ternary systems. Following that, the solubilities of metal sulfates in the quaternary systems H2SO4–Fe2(SO4)3–MgSO4–H2O, H2SO4–Fe2(SO4)3–Al2(SO4)3–H2O at 250 °C and H2SO4–Al2(SO4)3–MgSO4–H2O at 230–270 °C were predicted. The calculated results were in excellent agreement with the experimental data.  相似文献   

18.
In this paper, we summarise our recent research interest in the hydrothermal synthesis and structural characterisation of multi-dimensional coordination polymers. The use of N-(phosphonomethyl)iminodiacetic acid (also referred to as H4pmida) in the literature as a versatile chelating organic ligand is briefly reviewed. This molecule plays an important role in the formation of centrosymmetric dimeric [V2O2(pmida)2]4− anionic units, which were first used by us as building blocks to construct novel coordination polymers. Starting with [V2O2(pmida)2]4− in solution, we have isolated [M2V2O2(pmida)2(H2O)10] species (where M2+ = Mn2+, Co2+ or Cd2+) via the hydrothermal synthetic approach, which were then employed for the construction of [CdVO(pmida)(4,4′-bpy)(H2O)2]·(4,4′-bpy)0.5·(H2O), [CoVO(pmida)(4,4′-bpy)(H2O)2]·(4,4′-bpy)0.5, [Co(H2O)6][CoV2O2(pmida)2(pyr)(H2O)2]·2(H2O) and [Cd2V2O2(pmida)2(pyr)2(H2O)4]·4(H2O) by the inclusion of bridging organic ligands in the reactive mixtures, such as pyrazine (pyr) and 4,4′-bipyridine (4,4′-bpy). These materials can contain channel systems, and exhibit magnetic behaviour, not only due to the V4+ centres but also to the transition metal centres which establish the links between neighbouring dimeric [V2O2(pmida)2]4− anionic units. A closely related anionic moiety, [Ge2(pmida)2(OH)2]2−, was engineered to allow the study of such crystalline hybrid materials using one- and two-dimensional high-resolution solid-state NMR.  相似文献   

19.
Cheng DH  Chen XW  Shu Y  Wang JH 《Talanta》2008,75(5):1270-1278
Ionic liquid was for the first time employed for selective isolation of heme-protein species. Direct extraction of hemoglobin into ionic liquid without using any concomitant reagent or extractant was carried out. Hemoglobin at the level of 100 ng μL−1 could readily be quantitatively extracted into ionic liquid (IL) 1-butyl-3-trimethylsilylimidazolium hexafluorophosphate (BtmsimPF6) in the absence of any co-existing extractants/additives at pH 7, at the same time; however, the other protein species do not interfere and remain in the aqueous phase. A back extraction efficiency of ca. 80% for 20 ng μL−1 hemoglobin in ionic liquid phase was achieved with sodium dodecyl sulfate (SDS) solution as stripping reagent. 57Fe Mossbauer spectra and circular dichroism (CD) spectra indicated that the penta-coordinated ferrous atom in hemoglobin provide a vacant or free coordinating position, which could be occupied by the cationic Btmsim+ moiety. The interaction/coordination reaction between the iron atom in the heme group of hemoglobin and the cationic ionic liquid moiety furnishes the driving force for facilitating fast transfer of hemoglobin into BtmsimPF6. The present system was applied for selective isolation of heme-protein, i.e., hemoglobin from human whole blood without any pretreatment, giving rise to satisfactory results.  相似文献   

20.
Campuzano S  Pedrero M  Pingarrón JM 《Talanta》2005,66(5):1310-1319
The construction and performance under flow-injection conditions of an integrated amperometric biosensor for hydrogen peroxide is reported. The design of the bioelectrode is based on a mercaptopropionic acid (MPA) self-assembled monolayer (SAM) modified gold disk electrode on which horseradish peroxidase (HRP, 24.3 U) was immobilized by cross-linking with glutaraldehyde together with the mediator tetrathiafulvalene (TTF, 1 μmol), which was entrapped in the three-dimensional aggregate formed.

The amperometric biosensor allows the obtention of reproducible flow injection amperometric responses at an applied potential of 0.00 V in 0.05 mol L−1 phosphate buffer, pH 7.0 (flow rate: 1.40 mL min−1, injection volume: 150 μL), with a range of linearity for hydrogen peroxide within the 2.0 × 10−7–1.0 × 10−4 mol L−1 concentration range (slope: (2.33 ± 0.02) × 10−2 A mol−1 L, r = 0.999). A detection limit of 6.9 × 10−8 mol L−1 was obtained together with a R.S.D. (n = 50) of 2.7% for a hydrogen peroxide concentration level of 5.0 × 10−5 mol L−1. The immobilization method showed a good reproducibility with a R.S.D. of 5.3% for five different electrodes. Moreover, the useful lifetime of one single biosensor was estimated in 13 days.

The SAM-based biosensor was applied for the determination of hydrogen peroxide in rainwater and in a hair dye. The results obtained were validated by comparison with those obtained with a spectrophotometric reference method. In addition, the recovery of hydrogen peroxide in sterilised milk was tested.  相似文献   


设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号