首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 24 毫秒
1.
表面等离体子波(SPW)可与入射光横磁波极化能量耦合并被共振激发,这种现象被称为表面等离体子共振现象(SPR)。主要利用扫描近场光学显微镜(SNOM)技术和表面等离体子共振现象技术相结合,来研究金膜表面等离体子共振。设计并建立了结构独特的新型Kretschmann型表面等离体子共振现象耦合装置,同时又设计了具有厚度梯度的表面等离体子的制备方法。在此基础上,测量了改变入射角条件下的表面等离体子共振曲线,测得该装置的等离体子共振角灵敏度为1°。并且对金膜表面进行表面等离体子共振条件下的扫描近场光学显微成像。实验结果表明,在共振时金膜表面的扫描成像比不共振时清晰,而且增加了很多细节。应用表面等离体子共振现象技术将可以明显提高扫描近场光学显微镜的信噪比、分辨力等性能。  相似文献   

2.
Kim IT  Kihm KD 《Optics letters》2007,32(23):3456-3458
The feasibility of surface plasmon resonance (SPR) imaging thermometry is tested as a potential tool for full-field and real-time temperature field mapping for thermally transient liquid mediums. Using the well-known Kretschmann's analysis [Physik 241, 313 (1971)]. parametric examinations are performed to delineate the effects of important optical properties, including seven different prism materials with different refractive index values and seven different measured dielectric constants for thin gold (Au) films (approximately 47.5 nm in thickness), on the temperature dependence of SPR reflectance intensity variations. Furthermore, a laboratory-implemented real-time SPR thermometry system demonstrates the full-field mapping capabilities for transient temperature field developments in the near-wall region when a hot water droplet (80 degrees C) contacts the Au metal surface (20 degrees C) and spreads either in an air- or in a water-surrounded environment.  相似文献   

3.
Xiqu Chen  Qiang Lv 《Optik》2010,121(9):818-820
The phase-shift interferometry combined with surface plasmon resonance (SPR) effect has been studied as a novel technique used to analyze the bio-surface, which measures the spatial phase variation of SPR reflected light. The spatial sensitivity of the SPR imaging sensor is improved over the conventional SPR imaging systems based on optical intensity.  相似文献   

4.
基于物理中发生在金属表面的表面等离激元现象 ,阐述表面等离激元共振生物传感分析原理 ;进而建立表面等离激元共振生物传感成像。给出应用表面等离激元共振研究生物单元相互作用的实例。  相似文献   

5.
A polymer substrate based surface plasmon resonance (SPR) technique was developed for detection of specific monoclonal antibody 10B2 (MAb 10B2) against bacterium Acidovorax avenae subsp. citrulli (Aac). The monolayer of Aac antigen was physically immobilized on 95:5 polystryrene – copoly acrylic acid (95PSMA) for detection of antibody. The amount of antigen–antibody binding was found to depend on the surface density of immobilized Aac on the sensor surface and the antibody concentration. The detection limit was 5 μg/ml which was lower than the required concentration during the normal production of the antibody at 10–100 μg/ml. This suggests a possible use of surface for the antibody screening. Moreover, an application in antibody screening was explored by combination of surface plasmon resonance imaging (SPR imaging) and antibody detection assay on the 95PSMA surface. Two antigens of bovine serum albumin (BSA) and Aac were used as a model system for antibody screening. The result shows that both antibodies can be distinguished using the immobilized antigens on the 95PSMA surface based SPR imaging technique.  相似文献   

6.
表面等离子共振谱半波全宽的算法探讨   总被引:1,自引:0,他引:1  
根据金属薄膜复介电常量的性质和衬底对表面等离子波波矢的微扰,对在波长调制下的表面等离子共振传感器输出光谱的半波全宽计算方法进行了探讨。建立了输出光谱的半波全宽与传感器各参量之间关系的数学表达式。将理论研究与实验结果进行对比后发现,两者吻合较好。文中的研究结果可为优化传感器的特性提供理论依据。  相似文献   

7.
We present a new type of biosensor. The principle of operation of the device is similar to conventional surface plasmon sensors, except that the ordinary metallic film in surface plasmon sensors is replaced by a one-dimensional photonic bandgap array. The advantages of using a photonic bandgap structure, instead of a metallic film, include enhanced sensitivity, physical and chemical robustness, and the ability to engineer the optical response of the device. We propose and elaborate a biosensor based on a onedimensional (1D) photonic crystal (PC) with a surface plasmon resonance (SPR). In comparison with standard SPR sensors that use silver (Ag ) or gold (Au) films, PC–Ag–PC–Au structures have narrower resonance widths, lower minimum reflectance, and higher sensitivity, making them a much better choice for biosensing applications. Moreover, the structure is compact (H = 1.139 μm), providing a better option in biosensing in comparison with other PC-SPR and conventional SPR sensors.  相似文献   

8.
We investigate the sensitivity enhancement of surface plasmon resonance (SPR) sensors using planar metallic films closely coupled to nanogratings. The strong coupling between localized surface plasmon resonances (LSPRs) presenting in metallic nanostructures and surface plasmon polaritons (SPPs) propagating at the metallic film surface leads to changes of resonance reflection properties, resulting in enhanced sensitivity of SPR sensors. The effects of thickness of the metallic films, grating period and metal materials on the refractive index sensitivity of the device are investigated. The refractive index sensitivity of nanograting-based SPR sensors is predicted to be about 543 nm/RIU (refractive index unit) using optimized structure parameters. Our study on SPR sensors using planar metallic films closely coupled to nanogratings demonstrates the potential for significant improvement in refractive index sensitivity.  相似文献   

9.
The adsorption of metal ions, a type of surface reaction on binary mixed self-assembled monolayers (SAMs) on a gold surface composed of 1,6-hexanedithiol (HDT) with 11-mercaptoundecanoic acid (MUA), was monitored by in situ surface plasmon resonance (SPR) measurements. The differential SPR reflectance (ΔR) enables the kinetics of adsorption of Pt2+ on the mixed SAMs to be investigated. Unlike single HDT SAM, kinetic analyses of the mixed SAMs showed that the rate of adsorption of Pt2+ was enhanced and that it was highly dependent on the fraction of MUA present. These SPR measurements suggest that the adsorption rate of metal ions can be readily manipulated simply by using mixed SAMs.  相似文献   

10.
The far-field and near-field properties of a spherical nematic liquid crystal (NLC) coated metal nanoparticle (NPs) have been investigated in an external field, basing on the quasistatic theory. The resonant wavelength is tunable by varying metallic material of core, anisotropy extent and thickness of liquid crystals (LCs). The field enhancement is along the incident polarization near the outer surface of the shell. The direction of field is reverse in the inner surface comparing with the one if outer shell. In contrast to isotropy shell, the surface plasmon resonance (SPR) shows an obvious red shift and field enhancement near outer surface of the shell always is stronger.  相似文献   

11.
表面等离子体共振(SPR)光学传感器能实现生物医学的快速、 无标记、 高精度检测,是生物化学分析的重要方法。 研制了基于波长调制型的Kretschmann结构表面等离子体共振(SPR)生物传感系统,研究了在体溶液传感方式下的传感性能。 利用不同浓度的乙醇和乙二醇溶液进行体溶液传感测试。 实验结果表明,在折射率低时共振波长对折射率变化响应的灵敏度低,但响应的线性度高;随着折射率增大,共振波长对折射率的响应变化的灵敏度提高。 在1.407 0~1.430 RIU折射率范围内,灵敏度高达11 487 nm·RIU-1。 传感器的共振波长的稳定性为0.213 8 nm,可分辨最小折射率趋近10-6 RIU。 所研制的波长调制型表面等离子共振传感器操作简单、 灵敏度高、 检测范围大,可实现浓度极低生物标记物的有效检测,在化学、 生物传感领域有重要的应用。  相似文献   

12.
The sensitivity of an angle-resolved surface plasmon resonance biosensor is not only determined by the shift of the resonance angle, but also the width of the SPR curves and reflective amplitude. The three factors should be considered simultaneously in designing a SPR biosensor. In this study, a H-shaped nano-grating-based SPR biosensor is proposed and the influence of different structural parameters on the performance is investigated by using rigorous coupled wave analysis (RCWA). Electric field distribution around the nano-grating are also given out to directly explain the performance difference for various structural parameters. Larger resonance angle shift, reflectance amplitude and sharper SPR curves’ width are obtained simultaneously under optimized structural parameters. Our study is usefully for understanding of the enhancement mechanism of the nano-grating SPR biosensor and also provides instructions for fabricating highly sensitive SPR biosensors. PACS 42.79.Dj; 42.81.Gs; 73.20.Mf; 07.07.Df  相似文献   

13.
For breaking through the sensitivity limitation of conventional surface plasmon resonance (SPR) biosensors, novel highly sensitive SPR biosensors with Au nanoparticles and nanogratings enhancement have been proposed recently.But in practice, these structures have obvious disadvantages.In this study, a nanohole based sensitivity enhancement SPR biosensor is proposed and the influence of different structural parameters on the performance is investigated by using rigorous coupled wave analysis (RCWA).Electromagnetic field distributions around the nanohole are also given out to directly explain the performance difference for various structural parameters.The results indicate that significant sensitivity increase is associated with localized surface plasmons (LSPs) excitation mediated by nanoholes.Except to outcome the weakness of other LSP based biosensors, larger resonance angle shift, reflectance amplitude, and sharper SPR curves' width are obtained simultaneously under optimized structural parameters.  相似文献   

14.
Fluorescent silver nanoparticles via exploding wire technique   总被引:2,自引:0,他引:2  
Aqueous solution containing spherical silver nanoparticles of 20–80 nm size have been generated using a newly developed novel electro-exploding wire (EEW) technique where thin silver wires have been exploded in double distilled water. Structural properties of the resulted nanoparticles have been studied by means of X-ray diffractometer (XRD) and transmission electron microscopy (TEM). The absorption spectrum of the aqueous solution of silver nanoparticles showed the appearance of a broad surface plasmon resonance (SPR) peak centered at a wavelength of 390 nm. The theoretically generated SPR peak seems to be in good agreement with the experimental one. Strong green fluorescence emission was observed from the water-suspended silver nanoparticles excited with light of wavelengths 340, 360 and 390 nm. The fluorescence of silver nanoparticles could be due to the excitation of the surface plasmon coherent electronic motion with the small size effect and the surface effect considerations  相似文献   

15.
The heterogeneous character of thin gold films prepared by thermal evaporation and the dependence of this heterogeneity on the rate of their deposition must be considered when exploiting their optical properties for biosensor purposes. For instance, the performance of thin gold films for surface plasmon resonance (SPR) biosensors may drastically be degraded if care is not taken to prepare a film with a high fraction of gold (>95%). We use three different models to interpret the SPR response of gold films prepared by thermal evaporation. We show that the interpretation of the SPR curves requires considering both a global heterogeneity of the gold films and a surface roughness. Our conclusions are further corroborated by scanning surface plasmon microscope (SSPM) images of these thin gold films.  相似文献   

16.
We report a facile method for controllable fabrication of high-density silver nanoparticle films with a widely adjustable surface plasmon resonance (SPR) frequency, based on the gas phase cluster beam deposition. On the one hand, we can control the particle size by depositing clusters on silica substrate. Light extinction spectra of the self-assembled Ag nanoparticles with various particle sizes are characterized and show two SPRs, in which a SPR exhibits a redshift from less 400 nm to more than 570 nm with an increase in the particle size, whereas the other shows a slight position shifting. On the other hand, the inter-particle distance of the self-assembled Ag nanoparticles can also be controlled by depositing clusters on silica glass coated with Formvar film, and the SPR wavelength shows a redshift from <400 nm to more than 560 nm, which can be attributed to the increase of the fraction of closely spaced nanoparticle pairs that are near-field coupled with the deposition mass. The size and coverage-dependent SPR properties are also compared with the results from the discrete dipole approximation calculations. The present method of tailoring metallic microstructures could find important applications in plasmonics.  相似文献   

17.
利用表面等离子体共振技术对屋尘螨重组变应原(rDer p2)与单克隆抗体之间的结合作用进行了研究,并且运用该技术对尘螨过敏患者血清与变应原之间的结合作用进行了初步探讨。变应原和抗体之间的结合通常是通过免疫吸附技术或者酶免法来进行研究的,这些方法一般需要对分析物进行标记,由于背景的影响和低灵敏度,目前对抗原和抗体的反应检测所用的免疫吸附技术的准确性还远不如表面等离子共振技术。用氨基偶联法将重组变应原rDer p2固定在CM5传感片表面上后,表面等离子体共振(SPR)技术检测的结果显示,rDer p2与尘螨过敏患者血清的结合作用比单克隆抗体要弱得多。而且,尘螨过敏不同患者血清与rDer p2的结合有很大的差异性。本研究为临床上对过敏疾病的诊断提供了一个简单、 快速和实时监控的检测手段。  相似文献   

18.
This paper proposes an optical method for measuring small displacements using the surface plasmon resonance (SPR) heterodyne interferometry. A heterodyne light beam reflected by a mirror passes through a hemisphere glass and then enters into a surface plasmon resonance apparatus at the resonant angle. A small displacement of the mirror will introduce a phase-difference variation between p- and s-polarizations of the light emerging from the SPR apparatus. The phase-difference variation can be precisely measured with the heterodyne interferometric technique, and the associated displacement can be estimated. The feasibility of this method was verified by experiment, and the displacement measurement resolution of about 1.4 nm over a traveling range of 6 μm was achieved. Our method of measurement has the merits of both common-path interferometry and heterodyne interferometry.  相似文献   

19.
从实验和理论两个方面,探讨了金属Ag不同掺杂浓度对Ag:Bi2O3复合膜线性和非线性光学性质的影响. 用吸收光谱研究了Ag浓度与Ag:Bi2O3复合膜表面等离子体共振带之间的关系;用皮秒Z-扫描技术研究了共振和非共振情况下(激发光波长分别为532nm和1064nm),金属Ag浓度与复合膜三阶非线性极化率的关系. 基于表面等离子体共振理论和局域场增强理论对复合膜进行了分析,得到了不同Ag浓度时Ag:Bi2O3复合膜的三阶非线性效应,研究了激发波长和金属浓度对复合膜线性和非线性光学性质的影响. 结果表明,等离子体共振增强和合适的金属掺杂浓度使得三阶极化率增强二个量级,在Ag浓度为35%左右和接近等离子体共振频率(相应吸收带位于560nm—622nm)的532nm激发时,χ(3)具有最大值2.4×10-9esu. 关键词: 金属纳米颗粒 复合膜 三阶非线性 表面等离子体共振  相似文献   

20.
The temperature dependence of the sensitivity of an optical sensor based on long-range surface plasmon resonance (LRSPR) is studied via theoretical modeling. Both the ‘angular interrogation’ and the ‘wavelength interrogation’ modes of operation are studied. In addition, the variation of the full width at half maximum of the LRSPR ‘reflectance dip’ is also studied as a function of temperature, which ultimately determines the temperature dependence of the sensitivity of the sensor when the reflectance is monitored at a fixed incident angle (‘reflectance interrogation’). It is found that while most of the time only the ‘reflectance interrogation’ mode leads to improved sensitivity for the LRSPR sensor compared to a conventional SPR sensor, the temperature stability of the operation of the LRSPR sensor is generally higher than (or at least comparable to) that of the SPR sensor. PACS 73.20.Mf; 07.07.Df  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号