首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 0 毫秒
1.
There is increased interest in accurately assessing the total dietary intake of vitamins from all sources, including foods and dietary supplements. Consequently, a Dietary Supplement Ingredient Database (DSID), based upon analytical values, is being established by USDA with support of the Office of Dietary Supplements (ODS), NIH. The DSID necessitated the development of a new SRM, 3280 — Multivitamin/Multimineral Tablets, by the National Institute of Standards and Technology (NIST), with support from the ODS. As a continuation of a long-term project to develop and validate new methods of determining water-soluble B vitamins in foods and dietary supplements, and as part of a collaborative effort with NIST to characterize SRM 3280, values for the vitamin contents of SRM 3280 have been generated by a liquid chromatographic isotope dilution mass spectrometric (LC/IDMS) method. Isotope-labeled (13C and/or 2H) B vitamins (B1-thiamine, B6-pyridoxine, B3-nicotinamide, and B5-pantothenic acid) were obtained from commercial sources, with the support of the ODS/NIH. Our LC/IDMS method uses a C18 reversed phase column, an Agilent 1100 HPLC system, and a Quattro Micro triple-quad mass spectrometer (MS). B vitamin determination was achieved using a gradient LC profile combined with MS/MS detection in multiple reaction monitoring mode. Stock solutions of the isotope-labeled vitamins were calibrated against USP standard solutions. The SRM tablets, with added amounts of the four isotope-labeled B vitamins, were extracted and the vitamins simultaneously determined in a single LC run, in contrast with the single-component determinations performed via IDMS. Unknown vitamin concentrations were calculated by comparing the ratios of the integrated LC peaks at the different masses of the unlabeled and labeled vitamins.  相似文献   

2.
采用更简便的流动相体系,建立了高效液相色谱法同时测定多维元素片中9种水溶性维生素的快速分析方法。以酸水解与离心的方法处理样品,用C8柱分离,流动相A为0.1%三氟乙酸的水溶液,B为甲醇,梯度洗脱,二极管阵列检测器(DAD)检测。28min内实现了9种水溶性维生素的同时分离测定。各维生素线性关系、精密度、回收率均良好。并使用美国国家标准技术研究院(NIST)的SRM3280多维元素片标准物质对方法进行了确认,运用此法测定了市售多维元素片中的水溶性维生素含量。该法可作为维生素片剂中水溶性维生素分离测定的质控方法。  相似文献   

3.
Four adrenergic amines [synephrine, octopamine, tyramine, and n-methyltyramine] were determined in a variety of Bitter Orange containing dietary supplements. Two extraction techniques were evaluated in detail: Soxhlet extraction and sonication extraction. A liquid chromatographic separation using a reversed-phase C(18) stationary phase and the ion-pairing reagent sodium dodecyl sulfate was developed to separate the Bitter Orange alkaloids. Ultraviolet absorbance detection at 220 nm and fluorescence detection with excitation at 273 nm and emission at 304 nm were used for the alkaloid detection. The method described was used for the assignment of the levels of the predominant alkaloids in three candidate standard reference materials containing Bitter Orange.  相似文献   

4.
Standard Reference Material 968e Fat-Soluble Vitamins, Carotenoids, and Cholesterol in Human Serum provides certified values for total retinol, γ- and α-tocopherol, total lutein, total zeaxanthin, total β-cryptoxanthin, total β-carotene, 25-hydroxyvitamin D3, and cholesterol. Reference and information values are also reported for nine additional compounds including total α-cryptoxanthin, trans- and total lycopene, total α-carotene, trans-β-carotene, and coenzyme Q10. The certified values for the fat-soluble vitamins and carotenoids in SRM 968e were based on the agreement of results from the means of two liquid chromatographic methods used at the National Institute of Standards and Technology (NIST) and from the median of results of an interlaboratory comparison exercise among institutions that participate in the NIST Micronutrients Measurement Quality Assurance Program. The assigned values for cholesterol and 25-hydroxyvitamin D3 in the SRM are the means of results obtained using the NIST reference method based upon gas chromatography-isotope dilution mass spectrometry and liquid chromatography-isotope dilution tandem mass spectrometry, respectively. SRM 968e is currently one of two available health-related NIST reference materials with concentration values assigned for selected fat-soluble vitamins, carotenoids, and cholesterol in human serum matrix. This SRM is used extensively by laboratories worldwide primarily to validate methods for determining these analytes in human serum and plasma and for assigning values to in-house control materials. The value assignment of the analytes in this SRM will help support measurement accuracy and traceability for laboratories performing health-related measurements in the clinical and nutritional communities.  相似文献   

5.
Two different isotope-dilution liquid chromatography/tandem mass spectrometry (LC/MS/MS) methods for the quantitative determination of folic acid (FA) in multivitamin/multielement tablets are reported. These methods represent distinct improvements in terms of speed and specificity over most existing microbiological and chromatographic methods for the determination of FA in dietary supplements. The first method utilizes an aqueous/organic-based extraction solvent combined with positive-ion mode LC/MS/MS detection of protonated [M + H]+ FA molecules and the second method utilizes a pure aqueous-based extraction solvent combined with negative-ion mode LC/MS/MS detection of deprotonated [M - H]- FA molecules. The LC/MS/MS methods exhibit comparable linear dynamic ranges (> or =3 orders of magnitude), limits of detection (0.02 ng on-column) and limits of quantification (0.06 ng on-column) for FA. Two methods employing different extraction and different MS detection modes were developed to allow method cross-validation. Successful validation of each measurement procedure supports the use of either method for the certification of FA levels in dietary supplements. The accuracy and precision of each measurement procedure were evaluated by applying each method to the quantitative determination of FA in a NIST standard reference material (NIST SRM 3280 multivitamin/multielement tablets). The FA measurement accuracy for both methods was > or =95% (based on the manufacturer's assessment of the FA level in SRM 3280) with corresponding measurement precision values (% RSD) of approximately 1%.  相似文献   

6.
A novel method for the determination of vitamin B12 by high-performance liquid chromatography with fluorescence detection is reported. The method was simple and highly sensitive with good precision. Vitamin B12 was analyzed by HPLC on a muBondapak C18 column (300x3.9 mm, 10 microm) with methanol-water (30:70) as mobile phase and fluorescence detection at 305 nm (with excitation at 275 nm). The calibration graph was linear from 1.000 to 100.0 ng ml(-1) for vitamin B12 with a correlation coefficient of 0.998 (n=6). The detection limit was 0.1 ng ml(-1). The method was successfully applied to the determination of vitamin B12 in vitamin B12 tablets, multivitamin tablets and fermentation medium. The recovery was from 94 to 102% and the relative standard deviation was in the range of 1.8 to 4.1%.  相似文献   

7.
The concentrations of caffeine and caffeine-related compounds in 2 ephedra-containing reference materials have been determined by 3 independent methods with measurements performed by the National Institute of Standards and Technology (NIST) and a collaborating laboratory. Results from the 3 methods were used for value assignment of caffeine, theobromine, and theophylline in these Standard Reference Materials (SRMs). The methods used at NIST to determine the concentration levels of caffeine, theobromine, and theophylline in SRM 3243 Ephedra-Containing Solid Oral Dosage Form and SRM 3244 Ephedra-Containing Protein Powder used reversed-phase liquid chromatography with absorbance detection and tandem mass spectrometry. These reference materials are part of the first suite in a series of NIST SRMs that provide concentration values for multiple components in dietary supplements. These SRMs are primarily intended for method validation and for use as control materials to support the analysis of dietary supplements and similar materials.  相似文献   

8.
Carotenoids and vitamins A and E in multivitamin tablets can be determined simultaneously by reversed-phased liquid chromatography (LC) with a programmable UV detector. Samples were dissolved in dimethyl sulfoxide and then extracted with hexane. A portion was injected onto a Symmetry C18, 150 x 4.6 mm id, 5 microns column and chromatographed with a mobile phase of acetonitrile--0.25% ammonium acetate in methanol and 0.05% triethylamine in dichloromethane. A step gradient was used. The system was operated at 25 degrees C with a flow rate of 1.5 mL/min. UV detection was at 325 nm for retinols, 285 nm for tocopherols, and 450 nm for carotenoids. Detection limits were less than 0.3 ng for retinol and retinyl acetate; 2 ng for alpha-tocopherol acid succinate; 10 ng for alpha-tocopherol, gamma-tocopherol, and alpha-tocopherol acetate; and 0.4 ng for alpha-carotene and beta-carotene. Intraday and interday coefficients of variation ranged from 1.40 to 5.20%. The sample preparation method and LC assay are practical for quality control and routine analysis of multivitamin tablets.  相似文献   

9.
A procedure for selecting a ternary eluant for the determination of the synthetic fat-soluble vitamins E acetate, A acetate, K3, and D2 in Hexavit, Undevit, and Hendevit multivitamin pharmaceutical preparations was proposed, and the composition of then-hexane-l,2-dichloroethane-n-butanol (86.42 :13.42: 0.16, vol %) eluant was optimized.  相似文献   

10.
Quantitative determination of vitamin B12 in B-complex tablets was performed by using multimode high-performance liquid chromatography. The multivitamin tablets (B1, B6 and B12) were sonicated for 30 min in methanol–water (50:50, v/v) and diluted to appropriated volume with the same solvent. The resulting solution was filtered and the filtrate was analysed on a phenylpropanolamine bonded silica column (15 cm×4.6 mm I.D., 5 μm). The optimized mobile phase was 30 mM phosphate buffer (pH 3.00) containing 6% (v/v) acetonitrile at a flow-rate of 1 ml min−1 and the detection was measured at 361 nm. The calibration graph prepared using standards was linear from 0.05 to 0.25 μg. The determination limit was 25 ng, the relative standard deviation was 0.47% and recovery from tablet solution was 100%. An analysis was completed in 5 min. The new method is simple, rapid and precise.  相似文献   

11.
12.
H. B. Li  F. Chen 《Chromatographia》2001,54(3-4):270-273
Summary A novel method for the simultaneous determination of twelve water- and fat-soluble vitamins has been established by high-performance liquid chromatography with diode array detection. The vitamins were analyzed on a μBondapak C18 column (300 × 3.9 mm, 10 μm) with methanol-KH2PO4 buffer (0.1 M, pH 7.0)-water as mobile phase in a gradient. The linearity of calibration graphs was compound-dependent and the detection limits ranged from 0.02 μg mL−1 to 0.5 μg mL−1. The method was successfully applied to determine vitamins in pharmaceutical preparations. The recoveries were from 95.1% to 103% and the relative standard deviations were in the range of 0.9% to 4.5%.  相似文献   

13.
复合维生素片剂中泛酸钙的反相高效液相色谱法测定   总被引:1,自引:0,他引:1  
用十八烷基硅烷键合硅胶为填充剂,以V(水):V(甲醇):V(H3PO4)=950:50:1为流动相,检测波长为210 nm,采用反相高效液相色谱法分离测定了两种复合维生素片剂中的泛酸钙,实验回收率在99.2%~103.4%之间,相对标准偏差RSD为0.6%~1.0%(n=5),检出限为41 ng.已用于复合维生素片剂中泛酸钙的测定.  相似文献   

14.
In the present work, a reversed-phase high-performance liquid chromatographic procedure has been developed for the determination of water-soluble vitamins (thiamine hydrochloride, pyridoxine hydrochloride, nicotinamide, riboflavin phosphoric ester and cyanocobalamine) and fat-soluble vitamins (retinol palmitate, cholecalciferol, -tocopherol acetate) in multi-vitamin pharmaceutical formulations. The sample treatment proposed consists of a solid-phase extraction with C18 AR cartridges that allow the separation of fat-soluble vitamins, which were retained on the sorbent, from water-soluble vitamins. Afterwards, the water-soluble vitamins were analysed by HPLC on a Nova-Pack C18 (150×3.9 mm, 4 μm) analytical column, using CH3OH–0.05 M CH3COONH4 as mobile phase The chromatographic analysis of the fat-soluble vitamins was carried out after their sequential elution with methanol and chloroform from C18 sorbent, on the above column. The mobile phase employed was MeOH–CH3CN (95:5, v/v) working at a flow-rate of 2 ml min−1 in isocratic mode. The solid-phase extraction for these vitamins had been previously optimised. The experimental variables studied were: application volume, elution solvents and cleaning solutions. The UV–Vis detection of vitamins was made at 270 nm for all the water-soluble vitamins (362 nm for B12) and 285 nm for the water-soluble and fat-soluble vitamins present in real samples at different concentration levels. The accuracy of the method was tested obtaining an average recovery ranging between 78 and 116%.  相似文献   

15.
微乳液相色谱法同时测定4种脂溶性维生素   总被引:1,自引:0,他引:1  
Yang J  Huang L  Huang G  Li N 《色谱》2011,29(10):995-999
建立了一种新的微乳体系,并成功地应用于微乳液相色谱法(MELC)快速分析脂溶性维生素VA、VD2、VD3和VE。通过对影响分离选择性的主要因素进行考察,得到最佳微乳体系组成为98%(v/v)(50 g/L十二烷基硫酸钠(SDS)-10%(质量分数)正丁醇-1.0%(质量分数)正辛烷-84%水(质量分数))-2%(v/v)乙腈。该微乳体系中,表面活性剂类型和浓度、油相正辛烷的含量、有机添加剂乙腈对脂溶性维生素的分离起到了重要的作用。以Venusil ASB C18色谱柱(150 mm×4.6 mm, 5 μm)为分离柱,流速为0.7 mL/min,检测波长为265 nm,柱温为40 ℃, VA、VD2、VD3和VE在20 min内达到基线分离。4种脂溶性维生素的保留时间和峰面积的相对标准偏差(RSD) (n=5)分别小于2.3%和3.0%; VA、VD2、VD3和VE的线性范围分别为22.0~88.0 mg/L、20.2~81.0 mg/L、24.3~97.2 mg/L和125.0~500.0 mg/L,相应的线性相关系数r2分别为0.9996、0.9994、0.9998、0.9998;检出限(S/N=3)分别为0.37、0.34、0.41和2.12 mg/L。本方法已成功应用于多维元素片(21)中VA与VE的测定,结果令人满意。  相似文献   

16.
A method employing HPLC with electrochemical detection for the rapid and simultaneous determination of vitamins A, D(3) and E is described. The method uses a C-18 reverse phase column and 2.5 mM HAcO-NaAcO in methanol-water (99:1, v/v) solution as the mobile phase. The compounds are quantified using amperometric detection with a glassy carbon electrode at a potential of + 1300 mV (vs. Ag/AgCl) and the results are compared with those obtained using UV detection at a wavelength of 280 nm. The method was successfully applied to the analysis of vitamins A, D(3) and E in yogurt samples. After saponification, fat-soluble vitamins were extracted and the methanolic solution of the extracts was injected directly into the chromatographic system, avoiding the clean-up step which is necessary when no electrochemical detection is used. Good recovery percentages were obtained.  相似文献   

17.
18.
19.
A micellar reversed-phase liquid chromatographic procedure was developed for the control of five water-soluble vitamins, B (nicotinamide), B1 (thiamine), B2 (riboflavin), B6 (pyridoxine and pyridoxamine), in multivitamin pharmaceutical formulations (capsules, pills and syrups). Optimization procedure includes studies about the composition of the mobile phase (sodium dodecyl sulphate and the modifiers propanol, butanol or pentanol), flow-rate and temperature. Chromatographic analysis of all vitamins was carried out using a single mobile phase of 0.1 M SDS-4% (v/v) pentanol at pH 3, in a C18 column in isocratic mode, and UV-detection at 270, 290 and 325 nm. The flow-rates selected were 1.0 ml/min in the interval 0 to 6 min, and 2.0 ml/min until the end of the chromatogram and temperature was 45 degrees C. In the micellar liquid chromatographic system, the samples were injected without pretreatment, and the analysis time was below 12 min. Repeatabilities and intermediate precision were achieved according to ICH, and were below 5%. When the method is applied to real samples, the amount found with respect to the declared compositions were within the 91-105% range. These results were similar to those obtained with a conventional 60:40 (v/v) methanol-water mixture for some of the vitamins, but with the advantage of use a single mobile phase for the analyses of the five vitamins, with direct injection of the samples and reduced toxicity, flammability, environmental impact and cost of the micellar-pentanol solutions.  相似文献   

20.
In Standard Reference Material 968b, fat-soluble vitamins and cholesterol in human serum, certified values are provided for cholesterol, retinol, retinyl palmitate, -tocopherol, trans--carotene, total -carotene (trans plus cis isomers), total -carotene, and lutein. Non-certified values are also reported for -tocopherol (includes -tocopherol), -tocopherol, zeaxanthin, -cryptoxanthin, trans-lycopene, trans-lycopene, trans--carotene, total lycopene, 9-cis-carotene, 13- plus 15-cis--carotene, and 15-cis--carotene. Both certified and non-certified values are based on the agreement among results from three different liquid chromatographic analytical procedures developed at NIST and from an interlaboratory comparison exercise among institutions that participate in a NIST-managed Micronutrients Measurement Quality Assurance Program. Cholesterol is certified in this material using the NIST isotope dilution/mass spectrometric definitive method.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号