首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 0 毫秒
1.
This paper describes for the first time the direct measurement of boric acid (B(OH)(3)) and borate (B(OH)(4) (-)) adduction to NAD(+) and NADH by electrospray ionization mass spectrometry (ESI-MS) and (11)B NMR spectroscopy. The analysis demonstrates that borate binds to both cis-2,3-ribose diols on NAD(+) forming borate monoesters (1 : 1 addition), borate diesters (1 : 2 addition) and diborate esters (2 : 1 addition), whereas, only borate monoesters were formed with NADH. MS in the negative ion mode showed borate was bound to a cis-2,3-ribose diol and not to the hydroxyl groups on the phosphate backbone of NAD(+), and MS/MS showed that the 1 : 1 addition monoester contained borate bound to the adenosine ribose. Boron shifts of borate monoesters and diesters with NAD(+) were observed at 7.80 and 12.56 ppm at pH 7.0 to 9.0. The esterifications of borate with NAD(+) and NADH were pH dependent with maximum formation occurring under alkaline conditions with significant formation occurring at pH 7.0. Using ESI-MS, the limit of detection was 50 micro M for NAD(+) and boric acid (1 : 1) to detect NAD(+)-borate monoester at pH 7.0. These results suggest esterification of borate with nicotinamide nucleotides could be of biological significance.  相似文献   

2.
The mitochondrial locus 16519T/C was used as a model for the evaluation of the benefits of ion-pair reversed-phase high-performance liquid chromatography on-line hyphenated to electrospray ionization time-of-flight mass spectrometry (ICEMS assay) for the determination of allelic frequencies of single nucleotide polymorphisms. This marker has gained interest in forensic science owing to its ability to increase the discrimination power of mitochondrial DNA testing as a consequence of its high variability across various populations. In a first set of experiments, artificial mitochondrial DNA mixtures prepared from all four theoretically possible 16519 alleles served as samples. Any allele occurring at a frequency of as low as 1–5% was unequivocally detectable irrespective of the kind of allelic mixture. Measured and expected allelic frequencies correlated well following correction of observed experimental bias, which was most probably attributable to differential PCR amplification and/or preferential ionization. For thirteen different T/C mixtures with C contents in the range 1.0–99.0%, an average error of 1.2% and a maximum error of 2.2% were observed. Furthermore, ICEMS was applied to the quantitative genotyping of eight selected individuals of which four were heteroplasmic with C contents in the range 1.9–34.1%. To check the reliability of these results, allelic proportions were additionally determined by a cloning assay. The results of the two assays correlated well (R 2=0.9971). In all cases, deviations were obtained that were smaller than 5.4%. The overall observed assay performance suggests that the described mass spectrometric technique represents one of the most powerful assays for the determination of allelic frequencies available today.   相似文献   

3.
In this work, the use of liquid chromatography coupled to electrospray time-of-flight mass spectrometry (LC-TOFMS) has been evaluated for the profiling of relatively low-molecular weight protein species in both genetically modified (GM) and non-GM maize. The proposed approach consisted of a straightforward sample fractionation with different water and ethanol-based buffer solutions followed by separation and detection of the protein species using liquid chromatography with a small particle size (1.8 μm) C(18) column and electrospray-time-of-flight mass spectrometry detection in the positive ionization mode. The fractionation of maize reference material containing different content of transgenic material (from 0 to 5% GM) led to five different fractions (albumins, globulins, zeins, zein-like glutelins, and glutelins), all of them containing different protein species (from 2 to 52 different species in each fraction). Some relevant differences in the quantity and types of protein species were observed in the different fractions of the reference material (with different GM contents) tested, thus revealing the potential use of the proposed approach for fast protein profiling and to detect tentative GMO markers in maize.  相似文献   

4.
The potential of electrospray ionization quadrupole-quadrupole-time-of-flight mass spectrometry (ESI-QqTOF-MS) for the characterization of synthetic nucleic acids was evaluated. Oligonucleotides ranging in size from 12 up to 51 nucleotides were analyzed via direct infusion MS as well as via liquid chromatography (LC) online hyphenated to MS. These experiments proved the outstanding mass spectrometric performance of the TOF mass analyzer in regard of accuracy, reproducibility, resolution, and sensitivity. During a 1-min run, the monoisotopic mass of (dT)(24) was measured with a maximum relative mass deviation of 7.64 ppm proving the high mass accuracy of the TOF analyzer. Over a period of 1 h, mean deviations were determined in the range between -3.58 ppm and 3.06 ppm demonstrating the high stability of the applied external calibration. The molecular mass of a 51-mer was measured with a deviation smaller than 3.23 ppm from the theoretical value. The resolution exceeded a value of m/Deltam = 20 000 (m is the measured mass and Deltam the full peak width at half-maximum), which enabled the separation of the isotopic peaks of all investigated oligonucleotides. Because of the outstanding transmission and detection efficiency of the TOF mass analyzer, detection limits in the amol/microl to low fmol/microl range were reached. The usability of LC-ESI-QqTOF-MS for the qualitative and quantitative analysis of synthetic oligonucleotide mixtures was demonstrated.  相似文献   

5.
The utility of liquid chromatography combined with time-of-flight mass spectrometry (LC/TOFMS) was demonstrated for studies on chiral unsaturated epoxy compounds, sex pheromones produced mainly by female moths in the family Geometridae. By electrospray ionization (ESI), each synthetic epoxyalkadiene derived from (Z,Z,Z)-3,6,9-triene with a C(18)-C(23) straight chain showed three ion series, [M + NH(4)](+), [M + H](+) and [M - OH](+), with high resolution and good sensitivity, indicating its molecular formula. In addition to these, characteristic fragment ions at m/z M - 57 and M - 71 for the 3,4-epoxides and at m/z M - 123 and 123 for the 9,10-epoxides were detected, whereas the 6,7-epoxides did not produce fragment ions that reflected their structures. Monitoring these diagnostic ions during the LC/MS analysis of a gland extract, the natural sex pheromone of the mulberry looper was confirmed to be (Z,Z)-cis-9,10-epoxy-3,6-octadecadiene, which was separable from the other positional isomers on an ODS column. Furthermore, (Z,Z)-cis-3,4-epoxy-6,9-nonadecadiene secreted by the Japanese giant looper was analyzed with a chiral column, and the stereochemistry was determined directly.  相似文献   

6.
Shi P  He Q  Song Y  Qu H  Cheng Y 《Analytica chimica acta》2007,598(1):110-118
Flavonoid O-diglycosides are important bioactive compounds from genus Citrus. They often occur as isomers, which makes the structural elucidation difficult. In the present study, the fragmentation behavior of six flavonoid O-diglycosides from genus Citrus was investigated using ion trap mass spectrometry in negative electrospray ionization (ESI) with loop injection. For the flavonoid O-rutinosides, [M − H − 308] ion was typically observed in the MS2 spectrum, suggesting the loss of a rutinose. The fragmentation patterns of flavonoid O-neohesperidosides were more complicated in comparison with their rutinoside analogues. A major difference was found in the [M − H − 120] ion in the MS2 spectrum, which was a common feature of all the flavonoid O-neohesperidosides. The previous literature for naringin located the loss of 120 Da to the glycan part, whereas the present study for naringin had shown that the [M − H − 120] ion was produced by a retro-Diels-Alder reaction in ring C, and this fragmentation pattern was confirmed by the accurate mass measurement using an orthogonal time-of-flight mass spectrometer. Combined with high performance liquid chromatography (HPLC) and diode array detection (DAD), the established approach to the structural identification of flavonoid O-diglycosides by ion trap mass spectrometry was applied to the analysis of extracts of two Chinese medicines derived from genus Citrus, namely Fructus aurantii and F. aurantii immaturus. According to the HPLC retention behavior, the diagnostic UV spectra and the molecular structural information provided by multistage mass spectrometry (MSn) spectra, 13 flavonoid O-glycosides in F. aurantii and 12 flavonoid O-glycosides in F. a. immaturus were identified rapidly.  相似文献   

7.
Arsenic pollution of public water supplies has been reported in various regions of the world. Recently, some cancer patients are treated with arsenite (AsIII); most Japanese people consume seafoods containing large amounts of negligibly toxic arsenic compounds. Some of these arsenic species are metabolized, but some remain intact. For the determination of toxic AsIII, a simple, rapid and sensitive method has been developed using electrospray ionization mass spectrometry (ESI-MS). AsIII was reacted with a chelating agent, pyrrolidinedithiocarbamate (PDC, C4H8NCSS-) and tripyrrolidinedithiocarbamate-arsine, As(PDC)3, extracted with methyl isobutyl ketone (MIBK). A 1 μL aliquot of MIBK layer was directly injected into ESI-MS instrument without chromatographic separation, and was detected within 1 min. Arsenate (AsV) was reduced to AsIII with thiosulfate, and then the total inorganic As was quantified as AsIII. This method was validated for the analysis of urine samples. The limit of detection of As was 0.22 μg L−1 using 10 μL of sample solution, and it is far below the permissible limit of As in drinking water, 10 μg L−1, recommended by the WHO. Results were obtained in < 10 min with a linear calibration range of 1-100 μg L−1. Several organic arsenic compounds in urine did not interfere with AsIII detection, and the inorganic As in the reference materials SRM 2670a and 1643e were quantified after the reduction of AsV to AsIII.  相似文献   

8.
A novel laser ablation and ionization time-of-flight mass spectrometer has been used for direct elemental analysis of alloys. The system was incorporated with an ion guide cooling cell to reduce the kinetic energy distribution for the purpose of better resolution. Parametric studies have been conducted on the system with respect to the buffer gas pressure and the distance from sample to the nozzle to obtain the maximal signal intensities. In order to obtain satisfactory relative sensitivity coefficients (RSC) for different elements, the influence of the laser irradiance, nozzle voltage, rf frequency and voltage of the hexapole were also investigated. Under the optimized conditions, the RSC of different elements were available for direct semi-quantitative analysis. The mass resolving power (FWHM) of the spectrometer was approximately 7000 (m/Δm) and the limit of detection (LOD) was 10− 6 g/g.  相似文献   

9.
A commercial system that is comprised of a CE coupled to an ESI triple quadrupole mass spectrometer was equipped with two capacitively coupled contactless conductivity detectors (C4Ds). The first C4D was positioned inside the original cartridge, and the second C4D was positioned as close as possible to the ESI probe entrance by using a 3D‐printed support. The C4Ds electropherograms were matched to the ESI‐MS electropherogram by correcting their timescales by the factor LT/LD, where LT and LD are the total capillary length and the length until the C4D, respectively. A general approach for method development supporting the simultaneous conductivity and MS detection is discussed, while application examples are introduced. These examples include the use of C4D as a simple device that dismiss the use of an EOF marker, a low‐selectivity detector that continuously provide information about unexpected features of the sample, and even a detector that can be more sensitive than ESI‐MS. The C4D used in this setup proved to have a smaller contribution to the peak broadening than ESI‐MS, which allowed that a C4D, positioned at 12 cm from the inlet of an 80‐cm‐long capillary, could be used to foresee position and shape of the peaks being formed 6.8 times slower at the ESI‐MS electropherogram.  相似文献   

10.
张颖  王红 《分析试验室》2007,26(5):62-64
PEPAMP是应用于工业循环水中的新一代高效阻垢剂.采用电喷雾电离质谱和质谱/质谱技术分析了合成产物,注射泵直接进样,正离子方式检测,方法简便、快速.通过EI-MS技术获得了目标产物PEPAMP及主要副产物的准分子离子峰,通过ESI-MS-MS技术获得了其碎片信息,并对目标化合物及主要副产物进行了精确质量测定,确定了目标化合物及主要副产物的结构.  相似文献   

11.
12.
Conventional electrospray ionization mass spectrometry (ESI-MS) is widely used for analysis of solution samples. The development of solid-substrate ESI-MS allows direct ionization analysis of bulky solid samples. In this study, we developed pipette-tip ESI-MS, a technique that combines pipette tips with syringe and syringe pump, for direct analysis of herbal powders, another common form of samples. We demonstrated that various herbal powder samples, including herbal medicines and food samples, could be readily online extracted and analyzed using this technique. Various powder samples, such as Rhizoma coptidis, lotus plumule, great burdock achene, black pepper, Panax ginseng, roasted coffee beans, Fructus Schisandrae Chinensis and Fructus Schisandrae Sphenantherae, were analyzed using pipette-tip ESI-MS and quality mass spectra with stable and durable signals could be obtained. Both positive and negative ion modes were attempted and various compounds including amino acids, oligosaccharides, glycosides, alkaloids, organic acids, ginosensides, flavonoids and lignans could be detected. Principal component analysis (PCA) based on the acquired mass spectra allowed rapid differentiation of closely related herbal species.  相似文献   

13.
Electrospray ionization mass (ESI-MS) spectrometry was used to investigate the nature of metal complexes of alachlor and their dissociations on activation. Ions of the first row transition metal series were employed to react with alachlor and the products were subjected to collision-induced dissociation (CID) for further structural characterization. The formation of diverse complex ions including doubly charged metal/alachlor complexes; [3L + M]2+ and [4L + M]2+ (L: alachlor and M: transition metal ions) were observed depending on the experimental conditions including the tube lens offset voltage (TLOV) and relative concentrations of alachlor and transition metal ions. It is clear that complexation with transition metal ions alters the reactive site of alachlor, promoting the loss of chlorine over the loss of CH3OH that is the major reaction pathway in uncomplexed system. Direct elimination of chlorine from alachlor molecule was confirmed by the use of MnBr2 instead of MnCl2. These evidences clearly illustrate the catalytic activities of the metal ions through insertion mechanism. The function of transition metal ions in complexation was emphasized comparing the fragmentation patterns with those of protonated molecule. A change in the oxidation state of copper from + 2 to + 1 during the dissociation of metal complex was observed in company with elimination of radicals which is specific for the copper complex ions.  相似文献   

14.
In-source collision-induced dissociation (CID) fragmentation features of multiclass flavonoid glycoconjugates were examined using liquid chromatography electrospray time-of-flight mass spectrometry. Systematic experiments were performed to search for optimal conditions for in-source fragmentation in both positive and negative ion modes. The objective of the study was to attain uniformly appropriate conditions for a wide range of analytes independently of the aglycone, the attached sugar part and the type of bond between the aglycone and the glycan moieties (O- or C-glycosides). Studied substances included representatives of flavonols, flavones, flavanones and anthocyanins and, regarding their glycan parts, mono-, di- and triglycosides with varying distribution of carbohydrate moieties (di-O-glycosides, O-diglycosides, O,C-diglycosides). The breakdown properties of the analytes along with the abundances of the characteristic diagnostic ions required for structural elucidation of complex flavonoid derivatives were evaluated. An optimized value was found for the instrument parameter (fragmentor voltage) affecting the in-source CID fragmentation of the analytes [230 V (ESI+) and 330 V (ESI-)]. Thus, appropriate performance in terms of both highly sensitive full-scan acquisition and fragmentation information was obtained for all the investigated flavonoids. In addition, singularities in the abundance of selected diagnostic ions (e.g. Y(0), Y(1) and Y*) due to variations in the interglycosidic linkage (rutinoside-neohesperidoside) in the glycan part were found and are also evaluated and discussed in detail. The combination of in-source CID fragmentation with high mass accuracy MS detection establishes a working basis for the development of versatile and useful LC-MS methods for wide-scope screening, non-targeted detection and tentative identification of flavonoid derivatives.  相似文献   

15.
This study demonstrates the first application of field-induced wooden-tip electrospray ionization (ESI) mass spectrometry (MS) for high-throughput analysis of herbal medicines. By application of an opposite and sample-contactless high voltage on the MS inlet rather than wooden tips, a high-throughput analysis device is easily set up, and a relatively fast analysis speed of 6 s per sample was successfully achieved. In addition, fast polarity switching between positive and negative ion detection mode is readily accomplished, which provides more complete chemical information for quality assessment and control of herbal medicines. By using the proposed method, various active ingredients present in different herbal medicines were rapidly detected, and the obtained mass spectra were served as the samples' fingerprints for tracing the origins, establishing the authenticity, and assessing the quality consistency and stability of herbal medicines. Our experimental results demonstrated that field-induced wooden-tip ESI-MS is a desirable method for high-throughput analysis of herbal medicines, with promising prospects for rapidly differentiating the origin, determining the authenticity, and assessing the overall quality of pharmaceuticals.  相似文献   

16.
Commercially available but completely unknown surfactants used in the tin-lead plating industry were successfully identified by using electrospray mass spectrometry and NMR spectroscopy techniques, preceded by liquid ionization mass spectrometry used to obtain the preliminary information. The mass spectral data suggested that ethoxylated nonionic surfactants having a homologous distribution of molecular weights like 520, 564, 608, 652, 696, etc. were present. The NMR data suggested the presence of two aromatic rings and a quaternary carbon for the hydrophobe moiety instead of the well-known alkyl chains or alkylphenols. The unknown surfactants were finally concluded to be novel nonionic 4-(alpha,alpha-dimethylbenzyl)-phenol ethoxylates.  相似文献   

17.
A new isocratic separation method was developed for separation of phospholipid (PL) classes based on a silica hydrophilic interaction liquid chromatography (HILIC) column with electrospray ionization (ESI) mass spectrometric detection. Although HILIC is typically used for polar compounds, also amphiphilic molecules like phospholipids can be separated very well. Compared to normal-phase (NP) chromatography, which is usually used for PL class separation, HILIC has the advantage to use on-line ESI-MS detection because its eluents are ESI compatible. Furthermore, this HILIC method is isocratic and hence less time consuming than most (gradient) NP HPLC methods. A chromatographic baseline separation of a standard mixture containing phosphatidylglycerol (PG), phosphatidylethanolamine (PE), phosphatidylcholine (PC), sphingomyelin (SM) and lysophosphatidylcholine (LPC) was achieved within a total run time of 17 min using a mobile phase consisting of acetonitrile, methanol and ammonium acetate 10 mM. The new method was subsequently tested on phospholipid fractions of a body fluid (human blood plasma) and a tissue extract (swine brain) whereby it achieved nearly the same baseline separation of the PL classes. The detected classes in both cases were PE, PC, SM and LPC.  相似文献   

18.
Pogue RT  Majidi V 《Talanta》1996,43(12):2143-2149
In this paper, we introduce laser desorption X-ray ionization for producing ions from the previously undetected neutral species present during laser desorption mass spectrometry. Studies involving the laser desorption of simple sugars were conducted to illustrate the differences between spectra with and without the X-ray source. Ionization was made possible by placing a 200 mCi Am X-ray source directly into the ionization chamber of a time-of-flight mass spectrometer.  相似文献   

19.
Arsenic species have been known to participate in a number of chemical and biological reactions, including oxidation-reduction reactions, acid-base reactions, covalent interactions, and methylation-demethylation reactions because of the element's multiple and interconvertible oxidation states. Little is known about the structure or bonding behavior between arsenic species and thiolcontaining biomolecules. Therefore, a better understanding of the bonding behavior and detailed information on the molecular structure for arsenic-thiol complexes is needed. As a result, we have investigated the interaction between arsenic species (arsenate (AsV), arsenite (AsIII), monomethylarsonic acid (MMAV), and dimethylarsinic acid (DMAV)) with biomolecules containing thiol groups (glutathione and cysteine) by electrospray ionization mass spectrometry (ESI-MS). These compounds were dissolved in methanol/water solution and introduced into the MS instrument in order to elucidate the direct bonding behavior of thiol group of biomolecules with arsenic species. In addition, further detailed structural information on this complex was obtained by collision-induced dissociation (CID) measurements.In each mass spectrum for mixture solutions between arsenic species and thiol compounds, various peaks such as protonated arsenic-thiol complexes, protonated noncomplexed thiol compounds, sodium bound cluster ions, and proton bound cluster ions were observed. In these mass spectra, the arsenic complexes were formed by interaction with thiol groups on the cysteine residues. These arsenic-thiol complexes produced a variety of fragment ions by cleavage of chemical bonds, and by interaction of other binding site on thiol compounds in tandem mass spectrometry experiments.  相似文献   

20.
It has been found that anionic σ-adducts formed in the reactions of highly electrophilic nitroarenes with selected carbanions, alkoxide anions and amines can be transferred to the gas phase using an electrospray ion source and the resulting ions can be studied using various mass spectrometry techniques in the solvent-free environment. This method can also be used for estimating the relative equilibrium constants of the σ-adduct formation reactions in a liquid phase.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号