首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 203 毫秒
1.
采用基质辅助激光解吸电离飞行时间质谱(MALDI-TOF-MS),对四硫富瓦烯化合物进行质谱表征。在所用的实验条件下,样品很容易解吸电离生成单电荷分子离子,得到单同位素分辨的质谱图。26种实际样品的质谱分析结果表明;MALDI-TOF-MS可以比其它质谱方法更有效、更方便地用于此类化合物的质谱分析,解决了此类化合物不易进行质谱鉴定的难题。  相似文献   

2.
A novel sample preparation method of matrix-assisted laser desorption/ionization mass spectrometry for polystyrene was reported. Compared to the conventional dried-droplet method, the efficiency of ionization and signal intensity of mass spectra were improved. The mechanism was also analyzed.  相似文献   

3.
Since the introduction of matrix-assisted laser desorption/ionization (MALDI) mass spectrometry the majority of research has focused on developing analytical methods for the qualitative determination of water soluble biomolecules such as proteins, peptides, carbohydrates, and oligonucleotides. This paper, however, reports the use of MALDI for the analysis of triacylglycerols and develops a new sample preparation method for nonpolar analytes. MALDI enables the rapid analyses of triacylglycerol (TAG) standards and mixtures of whole oils. The new method provides excellent shot to shot reproducibility, making quantification possible. Detection limits were in the mid femtomole range and the resolution was around 2000 which easily separated TAGs differing by one double bond. Sensitivity decreased with increasing molecular weight, causing biased results when analyzing complex mixtures with a significant range of molecular weight. In all cases only sodiated molecules and prompt losses of a fatty acid sodium salt were observed in the spectra. From this information it was possible to identify the three fatty acids on the glycerol backbone. Collision-induced dissociation was carried out on a triacylglycerol which proved to be useful for additional structural information, including the corroboration of the fatty acid components. With MALDI the percent compositions of TAGs in a standard olive oil was accurately determined. Finally, MALDI was used to examine the differences in lipid components between aged and fresh onion seeds, showing the potential of the technique for observing changes in lipid components in seeds.  相似文献   

4.
Huck CW  Bakry R  Huber LA  Bonn GK 《Electrophoresis》2006,27(11):2063-2074
In this review the most important techniques developed to hyphenate CE to MALDI-TOF-MS are summarized. The principles of the different interfaces and ways to solve the hyphenation problem are explained and discussed in detail. The most important applications especially in the proteomic field are reviewed, and the advantages of CE-MALDI-TOF-MS for the analysis of these compounds compared to other techniques such as ESI-MS are exhaustingly discussed from a critical point of view. CE coupled to MALDI-TOF-MS has started to overpass traditionally used CE-coupling techniques, especially CE-ESI-MS, offering the possibility to analyze samples of interest even weeks after CE analysis and using multiplexing systems for high-sample throughput.  相似文献   

5.
安美忱  刘宁 《色谱》2010,28(2):180-184
建立了高效液相色谱-基质辅助激光解吸电离串联飞行时间质谱(MALDI-TOF/TOF MS)分离鉴定牛乳铁蛋白素(bovine lactoferricin, LfcinB)的方法。采用胃蛋白酶酶解牛乳铁蛋白,酶解液离心后取上清液,经过离子交换色谱、反相液相色谱、透析等技术分离,对分离得到的目标产物进行抗菌活性分析、蛋白含量测定和MALDI-TOF/TOF MS鉴定。分离得到高活性的LfcinB,其相对分子质量为3124.89,蛋白含量为18.20 μg/mL。本方法具有精度高、分析速度快和分辨能力强等优点,是其他传统的分析鉴定LfcinB方法所无法比拟的,为进一步研究LfcinB奠定了基础。  相似文献   

6.
We report quantitative MALDI-TOF measurements for polydimethylsiloxane (PDMS) of two different molecular weights using the relative ratio of the signal intensities of integrated oligomer distributions for these two molecular weight distributions. By reporting the ratio of intensities of the integrals of two oligomer distributions, we assume that the ionization and desorption efficiencies, crystallization conditions and other factors affecting intensity are similar. Poly(methyl methacrylate) (PMMA-33,000) was mixed with PDMS samples to show whether the presence of another material might affect the desorption efficiency. Quantitative values for the number-average molecular weight (Mn), weight-average molecular weight (Mw) and polydispersities (D) were calculated using the oligomer distributions. The results show a linear relationship between the analyte concentrations and the signal intensities in the range from 1,000 Da to 10,000 Da, and the desorption efficiency of these two PDMS materials was the same even in the presence of PMMA.  相似文献   

7.
Taxanes are biologically active compounds that have been extensively used in pharmacology for their powerful anticancer properties. High specificity and low level sensitivity for analysis of these compounds have been obtained with reversed-phase high-pressure liquid chromatography/mass spectrometry (RP-HPLC/MS), but the number of applications of matrix-assisted laser desorption/ionization mass spectrometry (MALDI-MS) for low molecular weight analytes is rapidly growing. A new MALDI-MS approach for the rapid screening of a variety of taxanes and a tandem mass spectrometric (MS/MS) analysis of the most important and diagnostic taxane fragmentation pathways are proposed. A solid-phase extraction method followed by preliminary quantification is also reported.  相似文献   

8.
In this work, we wanted to devise a reliable method to characterize polymerized forms of tannins, their structural information and mass distribution. Size-exclusion chromatography (SEC) is a chromatographic technique used to determine molecular mass (weight) distributions of polymers. One important step in the data treatment is the modeling of the calibration curves. Polystyrenes (PS) are standards usually used because no commercial procyanidin (PC) standards are available. An off-line coupling of SEC and MALDI was carried out to measure differences between polystyrenes and procyanidins. Thus, a new calibration curve was established; from 1000 to 8000 Da, there is a good correlation between the MALDI and PS calibration curves, in this field the PS calibration is correct and enables true mass determination. For masses above 8000 Da, PS calibration overestimates the real molecular weight of PC, overestimation of 53%. And for masses below 1000 Da, PS calibration underestimates their real molecular weight (10-15%). This means that to truly characterize PC, calibration based on PC standards is required.  相似文献   

9.
The use of collision-induced dissociation, postsource decay (CID-PSD) matrix-assisted laser desorption/ionization (MALDI) mass spectrometry for the analysis of small organic molecules is demonstrated. Three pesticides: paraquat, diquat, and difenzoquat were chosen for this study. The matrices 2,5-dihydroxybenzoic acid (DHB), alpha-cyano-4-hydroxycinnamic acid (alpha-CHCA), and sinapinic acid (SA) were selected to investigate the effect of the matrix on the CID-PSD MALDI spectra of these molecules. Alpha-CHCA and DHB were found to be appropriate matrices for the pesticides studied. Spectra for a given pesticide obtained from different matrices were compared with each other, and the differences between them are discussed. A comparison of CID-PSD MALDI with fast-atom bombardment MS/MS spectra is presented; the agreement of pesticide fragmentation patterns between the two methods indicates that CID-PSD MALDI MS is a reliable and efficient technique for structural elucidation of small molecules.  相似文献   

10.
A new photocleavable molecule for laser desorption ionization mass spectrometry (LDI-MS) was designed and synthesized. The molecule exhibited high sensitivity for negative mode MS detection with good chemical stability. The molecule was successfully applied to molecular tag for (LDI-MS). Kinetic measurement of the amidation reaction and monitoring of aminolysis of acetylated sugars were demonstrated with the molecular tag.  相似文献   

11.
This report focuses on the heterogeneous distribution of small molecules (e.g. metabolites) within dry deposits of suspensions and solutions of inorganic and organic compounds with implications for chemical analysis of small molecules by laser desorption/ionization (LDI) mass spectrometry (MS). Taking advantage of the imaging capabilities of a modern mass spectrometer, we have investigated the occurrence of “coffee rings” in matrix-assisted laser desorption/ionization (MALDI) and surface-assisted laser desorption/ionization (SALDI) sample spots. It is seen that the “coffee-ring effect” in MALDI/SALDI samples can be both beneficial and disadvantageous. For example, formation of the coffee rings gives rise to heterogeneous distribution of analytes and matrices, thus compromising analytical performance and reproducibility of the mass spectrometric analysis. On the other hand, the coffee-ring effect can also be advantageous because it enables partial separation of analytes from some of the interfering molecules present in the sample. We report a “hidden coffee-ring effect” where under certain conditions the sample/matrix deposit appears relatively homogeneous when inspected by optical microscopy. Even in such cases, hidden coffee rings can still be found by implementing the MALDI-MS imaging technique. We have also found that to some extent, the coffee-ring effect can be suppressed during SALDI sample preparation.  相似文献   

12.
This article reports the results of a study carried out to evaluate the offline hyphenation of capillary zone electrophoresis with matrix-assisted lased desorption ionization time of flight mass spectrometry (MALDI-TOF-MS) for the analysis of low-abundant complex samples, represented by the tryptic phosphorylated peptides of phosphoproteins, such as α-casein, β-casein, and fetuin. The proposed method employs a latex-coated capillary and consists in the online preconcentration of the tryptic peptides by a pH-mediated stacking method, their separation by capillary zone electrophoresis, and subsequent deposition of the separated analytes onto a MALDI target for their MS analysis. The online preconcentration method allows loading a large sample volume (~150?nL), which is introduced into the capillary after the hydrodynamic injection of a short plug of 1.0?M ammonium hydroxide solution and is sandwiched between two plugs of the acidic background electrolyte solution (BGE) filling the capillary. The sample spotting of the separated analytes onto the MALDI target is performed either during or postseparation using an automatic spotting device connected to the exit of the separation capillary. The proposed method allows the separation and identification of multiphosphorylated peptides from other peptides and enables their identification at femtomole level with improved efficiency compared with LC approaches hyphenated to MS.  相似文献   

13.
We report on the simple deposition of Stöber silica nanoparticles (SiO2 NPs) on conventional MALDI target plate for high throughput laser desorption/ionization mass spectrometry (LDI-MS) analyses of peptide mixtures with sensitivity in the femtomolar range. This low-cost easily prepared material allowed straightforward LDI experiments by deposition of the studied samples directly onto a pre-spotted MALDI plate. This analytical strategy can be performed in any laboratory equipped with a MALDI-TOF instrument. All key benefits of organic matrix-free technologies were satisfied while maintaining a high level of detection performances (sensitivity and reproducibility/repeatability). In particular, sample preparation was simple and detection in the low mass range was not hampered by matrix ions. Imaging studies were undertaken to query sample dispersion into the inert SiO2 NPs and to help into the search of the best experimental conditions producing homogeneous analyte distribution within the deposit. In contrast to commercial disposable LDI targets designed for single use and requiring an adaptor such as NALDI™, the proposed SiO2 NPs pre-spotting on a MALDI target plate allowed very easily switching between MALDI and LDI experiments. They can be conducted either simultaneously (positions with an organic matrix or SiO2 NPs) or in the row (support prepared in advance, stored and washed after use). The overall cost and versatility of the methodology made it very attractive to MALDI users in many domains (peptidomics, proteomics, metabolomics).  相似文献   

14.
Visible matrix-assisted laser desorption/ionization (VIS-MALDI) was performed using 2-amino-3-nitrophenol as matrix. The matrix is of near-neutral pH, and has an optical absorption band in the near-UV and visible region. A frequency-doubled Nd:YAG laser operated at 532 nm wavelength was used for matrix excitation and comparisons were made with a frequency-tripled Nd:YAG laser (355 nm). Visible and ultraviolet (UV)-MALDI produce similar mass spectra for peptides, polymers, and small proteins with comparable sensitivities. Due to the smaller optical absorption coefficient of the matrix at 532 nm wavelength, the optical penetration depth is larger, and the sample consumption per laser shot in VIS-MALDI is higher than that of UV-MALDI. Nevertheless, VIS-MALDI using 2-amino-3-nitrophenol as matrix may offer a complementary technique to the conventional UV-MALDI method in applications where deeper laser penetration is required.  相似文献   

15.
Gold nanoparticles (AuNPs) are highly promising candidates as drug delivery agents into cells of interest. We describe for the first time the multiplexed analysis of nanoparticle uptake by cells using mass spectrometry. We demonstrate that the cellular uptake of functionalized gold nanoparticles with cationic or neutral surface ligands can be readily determined using laser desorption/ionization mass spectrometry of cell lysates. The surface ligands have "mass barcodes" that allow different nanoparticles to be simultaneously identified and quantified at levels as low as 30 pmol. Using this method, we find that subtle changes to AuNP surface functionalities can lead to measurable changes in cellular uptake propensities.  相似文献   

16.
The trend of miniaturization in bioanalytical chemistry is shifting from technical development to practical application. In matrix-assisted laser desorption/ionization mass spectrometry (MALDI-MS), progress in miniaturizing sample spots has been driven by the needs to increase sensitivity and speed, to interface with other analytical microtechnologies, and to develop miniaturized instrumentation.We review recent developments in miniaturizing sample spots for MALDI-MS. We cover both target modification and microdispensing technologies, and we emphasize the benefits with respect to sensitivity, throughput and automation.We hope that this review will encourage further method development and application of miniaturized sample spots for MALDI-MS, so as to expand applications in analytical chemistry, protein science and molecular biology.  相似文献   

17.
Matrix-assisted laser desorption/ionization (MALDI) was used for the on-line analysis of single particles. An aerosol was generated at atmospheric pressure and particles were introduced into a time-of-flight (TOF) mass spectrometer through a single-stage differentially pumped capillary inlet. Prior to entering the mass spectrometer, a matrix was added to the particles using a heated saturator and condenser. A liquid matrix, 3-nitrobenzyl alcohol (NBA), and a solid matrix, picolinic acid (PA), were used. Particles were ablated with a 351 nm excimer laser and the resulting ions were mass-separated in a two-stage reflectron TOF mass spectrometer. Aerosol particles containing the biomolecules erythromycin and gramicidin S were analyzed with and without the matrix addition step. The addition of NBA to the particles resulted in mass spectra that contained an intact molecular ion mass peak. In contrast, PA-coated particles did not yield molecular ion peaks from matrix-coated particles.  相似文献   

18.
We propose and evaluate a new mechanism to account for analyte ion signal enhancement in ultraviolet-laser desorption mass spectrometry of droplets in the presence of corona ions. Our new insights are based on timing control of corona ion production, laser desorption, and peptide ion extraction achieved by a novel pulsed corona apparatus. We demonstrate that droplet charging rather than gas-phase ion-neutral reactions is the major contributor to analyte ion generation from an electrically isolated droplet. Implications of the new mechanism, termed charge assisted laser desorption/ionization (CALDI), are discussed and contrasted with those of the laser desorption atmospheric pressure chemical ionization method (LD-APCI). It is also demonstrated that analyte ion generation in CALDI occurs with external electric fields about one order of magnitude lower than those needed for atmospheric pressure matrix assisted laser desorption/ionization or electrospray ionization of droplets.  相似文献   

19.
We analyzed oligonucleotides by nanoparticle-assisted laser desorption/ionization (nano-PALDI) mass spectrometry (MS). To this end, we prepared several kinds of nanoparticles (Cr-, Fe-, Mn-, Co-based) and optimized the nano-PALDI MS method to analyze the oligonucleotides. Iron oxide nanoparticles with diammonium hydrogen citrate were found to serve as an effective ionization-assisting reagent in MS. The mass spectra showed both [M - H](-) and [M + xMe(2+)- H](-) (Me: transition metal) peaks. The number of metal-adducted ion signals depended on the length of the oligonucleotide. This phenomenon was only observed using bivalent metal core nanoparticles, not with any other valency metal core nanoparticles. Our pilot study demonstrated that iron oxide nanoparticles could easily ionize samples such as chemical drugs and peptides as well as oligonucleotides without the aid of an oligonucleotide-specific chemical matrix (e.g., 3-hydroxypicolinic acid) used in conventional MS methods. These results suggested that iron-based nanoparticles may serve as the assisting material of ionization for genes and other biomolecules.  相似文献   

20.
黄宇  任皓威  刘彪  刘宁  李萌  王东茂 《色谱》2013,31(5):429-434
以新鲜中国人乳为研究对象,在酸性条件下加氯化钙分离酪蛋白,用十二烷基磺酸钠-聚丙烯酰胺凝胶电泳(SDS-PAGE)法测定分离效果。从pH值、离心力和CaCl2浓度等3个方面对分离效果进行评价。结果表明:当pH=4.3,离心力为10 400 g,CaCl2溶液浓度为60 mmol/L时,分离得到的酪蛋白组分纯度最高。对所得酪蛋白沉淀进行DEAE阴离子交换色谱分离,得到3个洗脱液。对其中第3个峰进行Western-Blot法及基质辅助激光解吸电离串联飞行时间质谱法(MALDI-TOF/TOF MS)鉴定,证明该峰能与人β-酪蛋白抗体特异性结合,确认其为人乳β-酪蛋白;将质谱结果在Mascot数据库中进行数据检索,序列覆盖率为50%,进一步确定其为人乳β-酪蛋白。综上所述,我们建立了能够得到符合蛋白质组学研究要求的人乳β-酪蛋白的方法。  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号