首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
In this paper, a novel automatic approach for the speciation of inorganic mercury (Hg(2+)), methylmercury (MeHg(+)) and ethylmercury (EtHg(+)) using multisyringe chromatography (MSC) coupled to cold-vapor atomic fluorescence spectrometry (CV/AFS) was developed. For the first time, the separation of mercury species was accomplished on a RP C18 monolithic column using a multi-isocratic elution program. The elution protocol involved the use of 0.005% 2-mercapthoethanol in 240 mM ammonium acetate (pH 6)-acetonitrile (99:1, v/v), followed by 0.005% 2-mercapthoethanol in 240 mM ammonium acetate (pH 6)-acetonitrile (90:10, v/v). The eluted mercury species were then oxidized under post-column UV radiation and reduced using tin(II) chloride in an acidic medium. Subsequently, the generated mercury metal were separated from the reaction mixture and further atomized in the flame atomizer and detected by AFS. Under the optimized experimental conditions, the limits of detection (3σ) were found to be 0.03, 0.11 and 0.09 μg L(-1) for MeHg(+), Hg(2+) and EtHg(+), respectively. The relative standard deviation (RSD, n=6) of the peak height for 3, 6 and 3 μg L(-1) of MeHg(+), Hg(2+) and EtHg(+) (as Hg) ranged from 2.4 to 4.0%. Compared with the conventional HPLC-CV/AFS hyphenated systems, the proposed MSC-CV/AFS system permitted a higher sampling frequency and low instrumental and operational costs. The developed method was validated by the determination of a certified reference material DORM-2 (dogfish muscle), and was further applied for the determination of mercury species environmental and biological samples.  相似文献   

2.
A liquid chromatography-inductively coupled plasma mass spectrometric (LC-ICP-MS) method for lead and mercury speciation analysis was described. Sample containing ionic lead and mercury compounds was subjected to liquid chromatographic separation before injection into the direct injection high efficiency nebulizer (DIHEN, 170-AA). The species studied include inorganic lead (Pb(II)), trimethyl lead (trimethyl-Pb), triethyl lead (triethyl-Pb), inorganic mercury (Hg(II)), methyl mercury (methyl-Hg) and ethyl mercury (ethyl-Hg), which were well separated by reversed-phase liquid chromatography with a C18 column as the stationary phase and a pH 2.8 solution of 0.2% (v/v) 2-mercaptoethanol, 1 mg L(-1) ETDA, 174.2 mg L(-1) sodium 1-pentanesulfonate and 12% (v/v) methanol as the mobile phase. The lead and mercury species in biological tissues were quantitatively extracted, into 10 g L(-1) EDTA and 0.2% (v/v) 2-mercaptoethanol solution taken in a closed centrifuge tube and kept on water bath, using microwaves at 65 degrees C for 2 min. The spike recovery of individual lead and mercury species determined by spiking the samples with suitable concentration of lead and mercury mixture standard were between 93% and 99%. The detection limits of the species studied were in the range 0.1-0.3 microg Pb L(-1) and 0.2-0.3 microg Hg L(-1). The procedure has been applied for the speciation analysis of two reference samples namely NRCC DOLT-3 Dogfish Liver and DORM-2 Dogfish Muscle and a swordfish sample obtained locally. The sum of the concentrations of individual species has been compared with the certified values for total lead and mercury to verify the accuracy of the method. The precision between sample replicates was better than 10% with LC-DIHEN-ICP-MS method.  相似文献   

3.
《Analytical letters》2012,45(17):2769-2779
A sensitive method for simultaneous determination of organic and inorganic mercury species has been developed and is presented in this study. The method is based on complex formation of mercury species with the emetine dithiocarbamate (emetine-CS2) ligand, HPLC separation, and tris(2,2′-bipyridine)ruthenium(III) chemiluminescence detection. The complexation reactions of the mercury species and emetine-CS2 ligand occurred instantaneously upon the addition of emetine-CS2 solution to the solution containing the mercury species. The complete separation of these complexes was achieved using an ODS column with 20 mM NaH2PO4-acetonitrile (52:48, v/v) containing 30 mM NaClO4 as an ion-pair reagent. The calibration graphs of these complexes were linear in the range from 1–100 µg/L. The detection limits were 0.27 µg/L, 0.33 µg/L, 0.39 µg/L, and 0.17 µg/L for methylmercury, ethylmercury, phenylmercury, and the mercury ion, respectively, at a signal-to-noise ratio of 3. The developed technique was validated by analyzing certified reference materials, CRM7402-a (cod fish, NMIJ) and CE464 (tuna fish, ERM), in combination with sonication-assisted acid leaching and liquid-liquid extraction. The emetine-CS2 ligand has been used for extraction, separation, and detection of mercury species. The results determined using the proposed method were in good agreement with the values of the certified reference materials. The MeHg+ and EtHg+ recoveries for the spiked samples were found to be almost 100%.  相似文献   

4.
Li Y  Jiang Y  Yan XP 《Electrophoresis》2005,26(3):661-667
Capillary electrophoresis (CE) was directly interfaced to flame-heated furnace atomic absorption spectrometry (FHF-AAS) via a laboratory-made thermospray interface for nanoliter trace element speciation. The CE-FHF-AAS interface integrated the superiorities of stable CE separation, complete sample introduction, and continuous vaporization for AAS detection without the need of extra external heat sources and any post-column derivation steps. To demonstrate the usefulness of the developed hybrid technique for speciation analysis, three environmentally significant and toxic forms of methylmercury (MeHg), phenylmercury (PhHg), and inorganic mercury (Hg(II)) were taken as model analytes. Baseline separation of the three mercury species was achieved by CE in a 60 cm long x 75 microm inner diameter fused-silica capillary at 20 kV and using a mixture of 100 mM boric acid and 10% v/v methanol (pH 8.30) as running electrolyte. The precision (relative standard deviation, RSD, n = 7) of migration time, peak area and peak height for the mercury species at 500 microg x L(-1) (as Hg) level were in the range of 0.9-1.2%, 1.5-1.9%, and 1.4-2.0%, respectively. The detection limit (S/N = 3) of three mercury species was 3.0 +/- 0.15 pg (as Hg), corresponding to 50.8 +/- 2.4 microg x L(-1) (as Hg) for 60 nL sample injection, which was almost independent on specific mercury species. The developed hybrid technique was successfully applied to the speciation analysis of mercury in a certified reference material (DORM-2, dogfish muscle).  相似文献   

5.
Inorganic mercury and methylmercury are determined in natural waters by injecting the filtered samples onto a low cost commercial flow injection system in which an anion exchange microcolumn is inserted after the injection loop (FIA-IE). If hydrochloric acid is used as the carrier solution, the HgCl4(2-) species (inorganic mercury) will be retained by the anion exchanger while the CH3HgCI species (methylmercury) will flow through the resin with negligible retention. Four anion exchangers and seven elution agents were checked, in a batch mode, to search for the best conditions for optimal separation and elution of both species. Dowex M-41 and L-cysteine were finally selected. Mercury detection was performed by cold vapour-electrothermal atomic adsorption spectrometry (HG-ETAAS). Both systems were coupled to perform the continuous on-line separation/detection of both inorganic mercury and methylmercury species. Separation and detection conditions were optimized by two chemometric approaches: full factorial design and central composite design. A limit of detection of 0.4 microg L(-1) was obtained for both mercury species (RSD < 3.0% for 20 microg L(-1) inorganic and methylmercury solutions). The method was applied to mercury speciation in natural waters of the Nerbioi-lbaizabal estuary (Bilbao, North of Spain) and recoveries of more than 95% were obtained.  相似文献   

6.
Gas-liquid chromatography is used to determine inorganic mercury in the presence and absence of organomercurials in water and biological media after alkylation or arylation. Best results for inorganic mercury were realized with pentacyanomethylcobaltate(III) and tetraphenylborate(III), via the generated methyl and phenyl mercurial. Tetraethyltin, forming ethylmercury, was less satisfactory. Lower detection limits with these reagents were in the range 10–30 ng Hg ml-1 of medium. Co-determination of inorganic mercury and various organomercurials was carried out by sequential or simultaneous procedures with several column temperatures and packings. Optimal Chromatographic results were achieved with Durapak Carbowax 400 (low K') on Porasil F and 10% DEGS on Anakrom SD.  相似文献   

7.
Solvent extraction, sonication, and microwave-assisted extractions in the presence of extraction agents (thioacetic acid, citric acid, cysteine, 2-mercaptoethanol, HCl + NaCl, etc.) were tested for the isolation of mercury species. A mixture of 6 M HCl and 0.1 M NaCl was selected as the most suitable extraction agent. The extraction efficiency was about 10% higher and the RSD below 3.3% when microwave-assisted extraction was applied instead of sonication. The liquid chromatography-cold vapour atomic fluorescence spectrometry (LC/CV-AFS) method was optimised and used for separation and determination of inorganic mercury cations and alkylated and arylated mercury species. Isocratic elution at a flow rate of 0.15 mL/min (with a mobile phase containing 0.05% 2-mercaptoethanol (pH = 5) and 7% methanol and with a stepwise increase of methanol content up to 100% MeOH in the 15th min) was used for separation of mercury species on a Hypersil BDS C18 RP column. The limits of detection of the LC/CV-AFS system were estimated as 0.2 microg/L (3%) for MeHg+, 0.07 microg/L (5.3%) for inorganic Hg, 0.06 microg/L (3.4%) for PhHg+, and 0.12 microg/L (4.4%) for EtHg with the corresponding RSDs at 5 microg/L (n = 10) given in parentheses. The concentrations (2-10 mg/kg fresh weight) of total mercury and methylmercury (90-99% of the total mercury) in selected fish obtained by HPLC/CV-AFS were in good agreement (absolute deviations 0.05 mg/kg) but more precise (RSDs <5.4% at 5 mg/L, n = 10) than those determined by GC coupled to an electron capture detector. The RSDs (3.1-8.2% and 4.1-9.0%) of the overall analytical procedure for the determination of total mercury (AMA 254) and methylmercury (HPLC/CV-AFS) were determined for intra-day and inter-day assays, respectively.  相似文献   

8.
An on-line inorganic and organomercury species separation, preconcentration and determination system consisting of cold vapor atomic absorption spectrometry (CV-AAS or CV-ETAAS) coupled to a flow injection (FI) method was studied. The inorganic mercury species was retained on a column (i.d., 3 mm; length 3 cm) packed to a height of 0.7 cm with a chelating resin aminopropyl-controlled pore glass (550 A) functionalized with [1,5-bis (2 pyridyl)-3-sulphophenyl methylene thiocarbonohydrazyde] placed in the injection valve of a simple flow manifold. Methylmercury is not directly determined. Previous oxidation of the organomercurial species permitted the determination of total mercury. The separation of mercury species was obtained by the selective retention of inorganic mercury on the chelating resin. The difference between total and inorganic mercury determined the organomercury content in the sample. The inorganic mercury was removed on-line from the microcolumn with 6% (m/v) thiourea. The mercury cold vapor generation was performed on-line with 0.2% (m/v) sodium tethrahydroborate and 0.05% (m/v) sodium hydroxide as reducing solution. The determination was performed using CV-AAS and CV-ETAAS, both approaches have been used and compared for the speciation of mercury in sea food. A detection limit of 10 and 6 ng l(-1) was achieved for CV-AAS and CV-ETAAS, respectively. The precision for 10 replicate determinations at the 1 microg l(-1) Hg level was 3.5% relative standard deviation (R.S.D.), calculated from the peak heights obtained. Both approaches were validated with the use of two certified reference materials and by spiking experiments. By analyzing the two biological certified materials, it was evident that the difference between the total mercury and inorganic mercury corresponds to methylmercury. The concentrations obtained by both techniques were in agreement with the certified values or with differences of the certified values for total Hg(2+) and CH(3)Hg(+), according to the t-test for a 95% confidence level. It is amazing how this very simple method is able to provide very important information on mercury speciation.  相似文献   

9.
A method based on the coupling of HPLC with ICP-MS with an on-line pre-concentration micro-column has been developed for the analysis of inorganic and methyl mercury in the dissolved phase of natural waters. This method allows the rapid pre-concentration and matrix removal of interferences in complex matrices such as seawater with minimal sampling handling. Detection limits of 0.07 ng L(-1) for inorganic mercury and 0.02 ng L(-1) for methyl mercury have been achieved allowing the determination of inorganic mercury and methyl mercury in filtered seawater from the Venice lagoon. Good accuracy and reproducibility was demonstrated by the repeat analysis of the certified reference material BCR-579 coastal seawater. The developed HPLC separation was shown to be also suitable for the determination of methyl mercury in extracts of the particulate phase.  相似文献   

10.
A sensitive and selective method is described for the simultaneous determination of inorganic and organic mercury compounds. The mercury compounds are extracted into toluene or chloroform with dithizone, and the dithizonates are separated by liquid chromatography on an ODS column. Complete resolution was obtained between methylethyl-, phenyl- and inorganic mercury with a mobile phase of THF/methanol (2:1) with 0.05 M acetate buffer pH 4 (62 + 38), containing 50 μM EDTA. The mercury chelates were detected spectrophotometrically at 475 nm. The detection limits were at the subnanogram level. The method is applicable to human urine, tap water and tomatoes.  相似文献   

11.
Liquid chromatography with pulsed amperometric detection (PAD) at an Au electrode was successfully applied for speciation of mercury: inorganic mercury, methylmercury and ethylmercury. The optimized conditions for triple-step potential waveforms utilized in PAD were: E1 1800 mV, t1 50 ms; E2 300 mV, t2 3850 ms; E3 750 mV, t3 100 ms; mercury oxidation was monitored at E3. With the eluent of HClO4 (0.10 M) + KCl (1.0 mM) + CH3CN (1.0%) at a flow rate 0.80 mL/min, three mercury species were fully separated in 6 min on a glass column (3 mm × 10 cm) packed with Chemcosorb C18 (5 μm). However, the first peak (inorganic mercury) was commonly overlapped by the solvent front. The relative standard deviations (n = 6) for methylmercury (15 ppb) and ethylmercury (30 ppb) were 4.2% and 2.8%, respectively. The linear range tested was 2 – 500 ppb (r = 0.9998) for methylmercury, and was 4 – 1000 ppb (r = 1.000) for ethylmercury. The detection limits (S/N = 3) were 1.2 ppb and 1.8 ppb for methylmercury and ethylmercury, respectively. The results of determination of the mercury-containing species thimerosat in three commercial contact-lens solutions agreed satisfactorily with the expected values.  相似文献   

12.
Bagheri H  Gholami A 《Talanta》2001,55(6):681-1150
A new, simple and sensitive method for the simultaneous determination of mercury(II) and methylmercury chloride at sub-ng l−1 levels in river waters is described. Inorganic and organic mercury were preconcentrated from fresh water samples simultaneously on a laboratory-made column containing 2-mercaptobenzimidazol loaded on silica gel and then quantitatively eluted with 0.05 M KCN solution and 2.0 M HCl to desorp inorganic and methylmercury species, respectively. After irradiation with an intensive UV source, MeHg+ was decomposed and mercury vapours were generated from inorganic and organic mercury using an acidic SnCl2 solution in a continuous flow system and were subsequently determined with a cold vapour atomic fluorescence (CV-AFS) spectrometer. Detection limits (3σ) were 0.07 and 0.05 ng l−1 (as Hg) for mercury(II) chloride and methylmercury chloride, respectively. Relative standard deviations of method (%R.S.D.) were 8.8 and 10 for inorganic and organomercuric species in the river water, respectively. The analysis of real samples, taken from different rivers, showed that inorganic mercury levels ranged from 4.0±0.6 to 12±1 ng l−1 (as Hg and 95% confidence limit) and methylmercury levels at 0.2±0.02 ng l−1(as Hg).  相似文献   

13.
A fully automated system for the direct determination of methylmercury (MeHg), ethylmercury (EtHg), phenylmercury (PhHg), and inorganic mercury (Hg(II)) at the ng/L level is described. It is based on solid phase extraction preconcentration incorporated in a flow injection (FI) system, high performance liquid chromatography (HPLC) separation, reduction combined with thermolysis and determination by cold vapour atomic absorption spectrometry (CVAAS). For preconcentration a microcolumn of bonded silica with octadecyl functional groups (C18 reversed phase material) was used as a sorbent for the mercury complexes formed on-line with ammonium pyrrolidine dithiocarbamate. Retained mercury species are eluted with a methanol-acetonitrile-water mixture and subjected to separation on an octadecylsilane (ODS) column before determination by CVAAS. The sensitivity of organo-mercury determination could be improved by using NaBH4 as a reductant combined with a thermolysis step. In order to perform on-line measurements the preconcentration microcolumn was mounted in a pressure-tight casing. Limits of detection for MeHg, EtHg, PhHg and Hg(II) employing a sample volume of 58.5 mL were 9, 6, 10 and 5 ng/L, respectively. The relative standard deviation (RSD) calculated from 9 repeated measurements was found to be 3.6%, 5.5%, 10.4% and 7.6% for MeHg, EtHg, PhHg and Hg(II), respectively. Finally, the application of this method for speciation of mercury in fish and human urine is described. Received: 10 March 1997 / Revised: 29 January 1998 / Accepted: 5 February 1998  相似文献   

14.
Kubán P  Hauser PC 《Electrophoresis》2005,26(16):3169-3178
Quantitative total ionic analysis of alcoholic and nonalcoholic beverages was performed by microchip capillary electrophoresis with external contactless conductivity detection. An electrolyte solution consisting of 10.5 mM histidine, 50 mM acetic acid, and 2 mM 18-crown-6 at pH 4.1 was used for the determination of NH(4) (+), K(+), Ca(2+), Na(+), and Mg(2+). Fast analysis of Cl(-), NO(3) (-), and SO(4) (2-) was achieved in 20 mM 2-(N-morpholino)ethanesulfonic acid /histidine electrolyte solution at pH 6.0 and the simultaneous separation of up to 12 inorganic and organic anions was performed in a solution containing 10 mM His and 7 mM glutamic acid at pH 5.75. Limits of detection ranged from 90 to 250 mug/L for inorganic cations and anions, and from 200 to 2000 mug/L for organic anions and phosphate. Calibration curves showed linear dependencies over one to two orders of magnitude when the stacking effect was minimized by injecting standard solutions prepared in background electrolyte solutions. Total analysis times of 35 and 90 s were achieved for the determination of 5 inorganic cations and for the simultaneous determination of 12 inorganic and organic anions, respectively, which represents a considerable reduction of analysis time compared to conventional separation methods used in food analysis.  相似文献   

15.
《Analytica chimica acta》2004,511(2):289-294
A piezoelectric detection system coupled with a liquid chromatographic system is developed for the speciation of inorganic mercury(II) and methylmercury. Piezoelectric detection has been demonstrated to be a very sensitive detection system for total mercury determination when a gold-coated piezoelectric quartz crystal was used. The analytical features of this detection unit make it very suitable to be used as a detector coupled with a liquid chromatographic system for monitoring mercury species. After separation by a chromatography column (Spherisorb ODS-2, 5 μm,  mm i.d.), mercury species are liberated and reduced, by using stannous chloride, and are detected as an amalgam on the gold-coated piezoelectric quartz crystal, the sensor subsequently was regenerated by passing a peroxydisulfate solution. This detector exhibits good sensitivity, it allows the determination of mercury at sub-ppb concentration levels (0.30-1.20 μg l−1). The precision, expressed as relative standard deviation, was ±2.7% (n=11) for a 0.5 μg l−1 total mercury concentration. The proposed method is free of interferences and it allowed the determination of inorganic mercury and methylmercury species in natural waters.  相似文献   

16.
King M  Paull B  Haddad PR  Macka M 《The Analyst》2002,127(12):1564-1567
Light emitting diodes (LEDs) are known to be excellent light sources for detectors in liquid chromatography and capillary electromigration separation techniques, but to date only LEDs emitting in the visible range have been used. In this work, a UV LED was investigated as a simple alternative light source to standard mercury or deuterium lamps for use in indirect photometric detection of inorganic anions using capillary electrophoresis with a chromate background electrolyte (BGE). The UV LED used had an emission maximum at 379.5 nm, a wavelength at which chromate absorbs strongly and exhibits a 47% higher molar absorptivity than at 254 nm when using a standard mercury light source. The noise, sensitivity and linearity of the LED detector were evaluated and all exhibited superior performance to the mercury light source (up to 70% decrease in noise, up to 26.2% increase in sensitivity, and over 100% increase in linear range). Using the LED detector with a simple chromate-diethanolamine background electrolyte, limits of detection for the common inorganic anions, Cl-, NO3-, SO4(2-), F- and PO4(3-) ranged from 3 to 14 microg L(-1), using electrostatic injection at -5 kV for 5 s.  相似文献   

17.
Methyl- and inorganic mercury were extracted from human whole blood samples, as their diethyldithiocarbamate complexes, into toluene and butylated by using a Grignard reagent. The mercury species were then separated by gas chromatography (on a 12 m non-polar DB-1 capillary column) and detected by a microwave-induced plasma atomic emission spectrometric (GC-MPD) system. The accuracy and precision of the proposed method were established by the analysis of Seronorm lyophilized human whole blood standards for methyl- and inorganic mercury. No statistical difference (t-test) between the sum of these two species determined by the GC-MPD based method and the recommended total mercury concentrations in the Seronorm samples was observed. Results for the determination of methyl- and inorganic mercury in 60 controls and 90 previously occupationally exposed (to inorganic mercury) workers are presented to illustrate the practical utility of the proposed method. No significantly elevated inorganic mercury concentrations between the two groups were evident.  相似文献   

18.
The purpose of the present work was to develop a simple, rapid, sensitive and accurate method for the simultaneous determination of inorganic mercury (Hg(2+)) and monomethylmercury compounds (MeHg) in natural water samples at the pg L(-1) level. The method is based on the simultaneous extraction of MeHg and Hg(2+)dithizonates into an organic solvent (toluene) after acidification of about 300 mL of a water sample, followed by back extraction into an aqueous solution of Na(2)S, removal of H(2)S by purging with N(2), subsequent ethylation with sodium tetraethylborate, room temperature precollection on Tenax, isothermal gas chromatographic separation (GC), pyrolysis and cold vapour atomic fluorescence spectrometric detection (CV AFS) of mercury. The limit of detection calculated on the basis of three times the standard deviation of the blank was about 0.006 ng L(-1) for MeHg and 0.06 ng L(-1) for Hg(2+)when 300 mL of water was analysed. The repeatability of the results was about 5% for MeHg and 10% for Hg(2+). Recoveries were 90-110% for both species.  相似文献   

19.
Capillary electrophoretic separation of four mercury species (inorganic Hg(2+), methyl-, ethyl-, and phenylmercury) was achieved in less than 8 min with an electrolyte consisting of 150 mM 2-amino-2-methyl-propanol (AMP) at pH 11.6. The analytes were complexed with 0.1% mercaptopropionic acid (MPA), separated in counter-EOF as anionic complexes, and detected by a contactless conductometric detector. Ion exchange preconcentration with on-column formation of MPA-mercury complexes was developed. Preconcentration factors of 25-150 were achieved and LODs in the range of 2.9-6.9 ng/mL were feasible. This method may prove to be applicable as a rapid screening method for mercury speciation in environmental samples.  相似文献   

20.
Zhang Z  Li D  Liu X  Subhani Q  Zhu Y  Kang Q  Shen D 《The Analyst》2012,137(12):2876-2883
An end-to-end differential measurement approach with capacitively coupled contactless conductivity detection (C(4)D) was applied to anion-exchange monolithic capillary column ion chromatography. The column was prepared by thermally initiated radical polymerization of poly(glycidyl methacrylate) in a fused-silica capillary of 320 μm i.d. and modified by quaternary ammonium latex surface coating. Two C(4)Ds were placed near both ends of the capillary column and the output difference between them was measured. With 15 mM potassium hydrogen phthalate used as the eluent, good separation of a mixture of inorganic anions (F(-), Cl(-), NO(2)(-), NO(3)(-)) was achieved. The detection limits of conventional C(4)D are 1.6, 0.28, 0.53, and 0.47 mg L(-1) for F(-), Cl(-), NO(2)(-), and NO(3)(-), respectively. To further enhance the sensitivity, the capacitive impedance from C(4)D was neutralized by an inductive impedance from a piezoelectric resonator. An increase in sensitivity by a factor of 7-8 was achieved in the resonating C(4)D in comparison with the conventional C(4)D. The detection limits of the resonating C(4)D are 0.23, 0.041, 0.065, and 0.059 mg L(-1) for F(-), Cl(-), NO(2)(-), and NO(3)(-), respectively. The response of the resonating C(4)D was analyzed based on an equivalent circuit model.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号