首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
A simple and sensitive reversed-phase liquid chromatography coupled with electrospray-mass spectrometry was developed and validated for the simultaneous determination of rivastigmine, a cholinesterase inhibitor, and its major metabolite NAP 226-90 in rat plasma and brain homogenates. Rivastigmine and NAP 226-90 were extracted from plasma and brain by ethyl acetate and, after drying under nitrogen, re-dissolved in acetonitrile and separated isocratic by HPLC on a C(18) column and quantified by single ion monitoring mass spectrometer. The mean (+/-SD) extraction efficiency for rivastigmine in plasma and brain was 93 +/- 2 and 95 +/- 2% (n = 5) of NAP 226-90 in a drug range of 10-100 pmol/mL or pmol/g. The method proved to be linear within the tested range (regression coefficient, r = 0.9999, n = 5). Intra- and inter-day precision coefficients of variation and accuracy bias were acceptable (within 15%, n = 5) over the entire range for both compounds using plasma or brain samples. The limits of quantification were 0.5 pmol/mL plasma and 2.5 pmol/g brain for rivastigmine and 1 pmol/mL plasma and 5 pmol/g brain for NAP 226-90, respectively. The analytical technique was used to determine the concentrations of rivastigmine and its metabolite NAP 226-90 in rat plasma and brain after oral drug administration. The concentrations of the parent drug and its major metabolite were compared to a pharmacodynamic parameter, the ex vivo inhibition of acetylcholinesterase.  相似文献   

2.
A sensitive and specific LC-MS/MS assay for the determination of paclitaxel and its 3'p- and 6-alpha-hydroxy metabolites is presented. A 200 microL plasma aliquot was spiked with a 13C6-labeled paclitaxel internal standard and extracted with 1.0 mL tert-butylmethylether. Dried extracts were reconstituted in 0.1 M ammonium acetate-acetonitrile (1:1, v/v) and 25 microL volumes were injected onto the HPLC system. Separation was performed on a 150 x 2.1 mm C18 column using an alkaline eluent (10 mm ammonium hydroxide-methanol, 30:70, v/v). Detection was performed by positive ion electrospray followed by tandem mass spectrometry. The assay quantifies a range for paclitaxel from 0.25 to 1000 ng/mL and metabolites from 0.25 to 100 ng/mL using 200 microL human plasma samples. Validation results demonstrate that paclitaxel and metabolite concentrations can be accurately and precisely quantified in human plasma. This assay is now used to support clinical pharmacologic studies with paclitaxel.  相似文献   

3.
A sensitive and specific high-performance liquid chromatography/tandem mass spectrometry (HPLC/MS/MS) assay for the quantitative determination of gemcitabine (dFdC) and its metabolite 2',2'-difluorodeoxyuridine (dFdU) is presented. A 200-microL aliquot of human plasma was spiked with a mixture of internal standards, didanosine, lamivudine and fludarabine, and extracted using solid-phase extraction. Dried extracts were reconstituted in 1 mM ammonium acetate/acetonitrile (97:3, v/v) and 10-microL volumes were injected onto the HPLC system. Separation was achieved on a 150 x 2.1 mm C18 bonded phase endcapped with polar groups (Synergi Hydro-RP column) using an eluent composed of 1 mM ammonium acetate (pH 6.8)/acetonitrile (94:6, v/v). Detection was performed by positive ion electrospray ionization followed by MS/MS. The assay quantifies a range from 0.5 to 1000 ng/mL for gemcitabine and from 5 to 10,000 ng/mL for dFdU using 200 microL of human plasma sample. Validation results demonstrate that gemcitabine and dFdU concentrations can be accurately and precisely quantified in human plasma. This assay is used to support clinical pharmacologic studies with gemcitabine.  相似文献   

4.
A sensitive, specific and efficient high‐performance liquid chromatography/tandem mass spectrometry (HPLC/MS/MS) assay for the simultaneous determination of total vincristine and actinomycin‐D concentrations in human plasma and an assay for the determination of unbound vincristine are presented. Electrospray ionization (ESI), atmospheric pressure chemical ionization (APCI) and heated electrospray ionization (H‐ESI) were tested as ionization interfaces. For reasons of robustness ESI was chosen followed by tandem mass spectrometry (ESI‐MS/MS). For the plasma assay a 30 µL aliquot was protein precipitated with acetonitrile/methanol (50:50, v/v) containing the internal standard vinorelbine and 10 µL volumes were injected onto the HPLC system. To determine unbound vincristine, ultrafiltrate was produced from plasma using 30 kDa centrifugal filter units. The plasma ultrafiltrate was mixed with methanol (50:50, v/v), internal standard vinorelbine was added and 20 µL aliquots were injected onto the HPLC system. Separation was achieved on a 50 × 2.1 mm i.d. Xbridge C18 column using 1 mM ammonium acetate/acetonitrile (30:70, v/v) adjusted to pH 10.5 with ammonia, run in a gradient with methanol at a flow rate of 0.4 mL/min. HPLC run time was 6 min. The assay quantifies in plasma vincristine from 0.25 to 100 ng/mL and actinomycin‐D from 0.5 to 250 ng/mL using plasma sample volumes of only 30 µL. Vincristine in plasma ultrafiltrate can be quantified from 1 to 100 ng/mL. Validation results demonstrate that vincristine and actinomycin‐D can be accurately and precisely quantified in human plasma and plasma ultrafiltrate with the presented methods. The assays are now in use to support clinical pharmacological studies in children treated with vincristine and actinomycin‐D. Copyright © 2009 John Wiley & Sons, Ltd.  相似文献   

5.
An assay method with mass spectrometric detection was developed for the quantitative analysis of a pharmaceutical compound and its major metabolite in human plasma using chip-based infusion. Liquid-liquid extraction sample preparation was found to be essential to minimize matrix suppression and to achieve a limit of quantitation (LOQ) of 2.5 ng/mL using a 100 microL plasma aliquot. The potential for simultaneous quantitation in selected reaction monitoring (SRM), tandem mass spectrometry (MS/MS) (enhanced product ion), and MS(3) was investigated and found to be very beneficial in improving assay selectivity. A novel concept for monitoring quantitative assay performance using a SRM/MS(3) ratio is proposed.  相似文献   

6.
The demand for high sensitivity bioanalytical methods has dramatically increased in the drug discovery stage; in addition, there has been a growing trend of reducing the sample volume that is required for these assays. A sensitive high-performance liquid chromatography/tandem mass spectrometry (HPLC/MS/MS) procedure has been developed and tested to meet these needs. The assay requires only a low plasma sample volume (10 microL) and employs a protein precipitation procedure using a 1:6 plasma/acetonitrile ratio. The supernatant is injected directly into the LC/MS/MS system using the selected reaction monitoring (SRM) procedure for detection. A generic HPLC gradient based on a methanol/water mobile phase with a flow rate set to 0.8 mL/min was used. The test method showed very good linearity between 0.1-1000 ng/mL (R2 = 0.9737), precision (%RSD = 6-9), accuracy (%RE = -2) and reproducibility (%RSD = 11). A drug discovery IV/PO study was assayed using both the new low volume method and our standard volume (50 microL) method. The correlation of the two sets of data from the two methods was excellent (R2 = 0.9287). This new assay procedure has been successfully used in our laboratory for over 100 different rat or mouse discovery PK studies.  相似文献   

7.
A simple and sensitive liquid chromatography‐tandem mass spectrometry (LC‐MS/MS) method was developed for the quantification of methylene blue (MB) and its major metabolite, azure B (AZB), in rat plasma. A simple protein precipitation using acetonitrile was followed by injection of the supernatant on to a Zorbax HILIC Plus column (3.5 µm, 2.1 × 100 mm) with isocratic mobile phase consisting of 5 mM ammonium acetate in 10:90 (v/v) water:methanol at a flow rate of 0.3 mL/min and detection in positive ionization mode. The standard curve was linear over the concentration range from 1 to 1000 ng/mL for MB and AZB with coefficient of determination above 0.9930. The lower limit of quantification was 1 ng/mL using 20 μL of rat plasma sample. The intra‐ and inter‐assay precision and accuracy were <12%. The developed analytical method was successfully applied to the pharmacokinetic study of MB and AZB in rats. Copyright © 2013 John Wiley & Sons, Ltd.  相似文献   

8.
A sensitive, specific and efficient high‐performance liquid chromatography/tandem mass spectrometry assay for the simultaneous determination of vinorelbine and its metabolite 4‐O‐deacetylvinorelbine in human and mouse plasma is presented. Heated electrospray ionization was applied followed by tandem mass spectrometry. A 50 µL plasma aliquot was protein precipitated with acetonitrile–methanol (1:1, v/v) containing the internal standard vinorelbine‐d3 and 20 µL volumes were injected onto the HPLC system. Separation was achieved on a 50 × 2.1 mm i.d. Xbridge C18 column using isocratic elution with 1 mm ammonium acetate–ammonia buffer pH 10.5–acetonitrile–methanol (28:12:60, v/v/v) at a flow rate of 0.4 mL/min. The HPLC run time was 5 min. The assay quantifies both vinorelbine and 4‐O‐deacetylvinorelbine from 0.1 to 100 ng/mL using sample volumes of only 50 µL. Mouse plasma samples can be quantified using calibration curves prepared in human plasma. Validation results demonstrate that vinorelbine and 4‐O‐deacetylvinorelbine can be accurately and precisely quantified in human and mouse plasma with the presented method. The assay is now in use to support (pre‐)clinical pharmacologic studies with vinorelbine in humans and mice. Copyright © 2009 John Wiley & Sons, Ltd.  相似文献   

9.
A sensitive, rapid and specific quantitative liquid chromatography/tandem mass spectrometry (LC/MS/MS) method was developed and validated for the determination of apomorphine (APO) in canine plasma. The analytes were prepared using one-step liquid-liquid extraction, and analyzed on a Waters Symmetry C(18) column interfaced with triple quadrupole tandem mass spectrometer. A mixture of methanol/0.1% formic acid in water (70: 30, v/v) was employed as the isocratic mobile phase. Positive electrospray ionization was utilized as the ionization source. The analyte and clenbuterol (internal standard) were both detected using multiple reaction monitoring (MRM) mode. The limit of detection (LOD) obtained was 0.03 ng/mL. The assay was linear over the concentration range of 0.1-100 ng/mL, and provided good precision (RSD) and good accuracy (RE). The analyte was stable by using antioxidants throughout the whole study. The experimental results show that LC/MS/MS is a rapid and sensitive method to analyze APO in plasma. Finally, the proposed method was successfully applied to a pharmacokinetic study of APO after intranasal administration of 0.5 mg apomorphine to 10 healthy beagle dogs.  相似文献   

10.
A rapid, sensitive, and simple ultra-performance liquid chromatography-tandem mass spectrometry (UPLC/MS/MS) method for the determination of udenafil and its active metabolite, DA-8164, in human plasma and urine using sildenafil as an internal standard (IS) was developed and validated. Udenafil, DA-8164 and IS from a 100 microL aliquot of biological samples were extracted by protein precipitation using acetonitrile. Chromatographic separation was carried on an Acquity UPLC BEH C(18) column (50 x 2.1 mm, i.d., 1.7 microm) with an isocratic mobile phase consisting of acetonitrile and containing 0.1% formic acid (75:25, v/v) at flow rate of 0.4 mL/min, and total run time was within 1 min. Detection and quantification was performed by the mass spectrometer using multiple reaction-monitoring mode at m/z 517 --> 283 for udenafil, m/z 406 --> 364 for DA-8164 and m/z 475 --> 100 for IS. The assay was linear over a concentration range of 1-600 ng/mL with a lower limit of quantification of 1 ng/mL in both human plasma and urine. The coefficient of variation of this assay precision was less than 13.7%, and the accuracy exceeded 92.0%. This method was successfully applied for pharmacokinetic study after oral administration of udenafil 100 mg to healthy Korean male volunteers.  相似文献   

11.
A sensitive and selective high-performance liquid chromatography-positive ion electrospray tandem mass spectrometry method was developed and validated for the quantification of amisulpride in 100 microL of human plasma. Following liquid-liquid extraction, the analytes were separated using an isocratic mobile phase on a reverse-phase column and analyzed by MS/MS in the multiple reaction monitoring mode using the respective (M + H)(+) ions, m/z 370-242 for amisulpride and m/z 341-112 for the internal standard. The assay exhibited a linear dynamic range with a lower range of 0.1-100 ng/mL and a higher range of 1-500 ng/mL of amisulpride in human plasma. The lower limit of quantification was 0.1 ng/mL with a relative standard deviation of less than 10%. Acceptable precision and accuracy were obtained for both linearity ranges. A run time of 2.0 min for each sample made it possible to analyze more than 275 human plasma samples per day. The validated method has been successfully used to analyze plasma samples for application in pharmacokinetic studies.  相似文献   

12.
Docetaxel is an antineoplastic agent widely used in therapeutics. The objective of this study was to develop and validate a routine assay, using liquid chromatography coupled to tandem mass spectrometry (LC/MS/MS), for the simultaneous quantification of docetaxel and its main hydroxylated metabolites in human plasma. A structural analogue, paclitaxel, was used as the internal standard. Determination of docetaxel and four metabolites (M1, M2, M3 and M4) was achieved using only 100 microL of plasma. Liquid-liquid extraction was used for sample preparation, with extraction efficiency of at least 90% for all analytes. Detection used positive-mode electrospray ionization in selected reaction monitoring mode. The lower limit of quantification (LLOQ) was 0.5 ng/mL for all analytes. The assay was linear in the calibration curve range 0.5-1000 ng/mL and acceptable precision and accuracy (<15%) were obtained with concentrations above the LLOQ. This method was sufficiently selective and sensitive for quantification of metabolites in plasma from cancer patients receiving docetaxel chemotherapy, and is suitable for routine analyses during pharmacokinetic studies.  相似文献   

13.
Kaletra is an important antiretroviral drug, which has been developed by Abbott Laboratories. It is composed of lopinavir (low-pin-a-veer) and ritonavir (ri-toe-na-veer). Both have been proved to be human immunodeficiency virus (HIV) protease inhibitors and have substantially reduced the morbidity and mortality associated with HIV-1 infection. We have developed and validated an assay, using liquid chromatography coupled with atmospheric pressure chemical ionization tandem mass spectrometry (LC/MS/MS), for the routine quantification of lopinavir and ritonavir in human plasma, in which lopinavir and ritonavir can be simultaneously analyzed with high throughput. The sample preparation consisted of liquid-liquid extraction with a mixture of hexane: ethyl acetate (1:1, v/v), using 100 microL of plasma. Chromatographic separation was performed on a Waters Symmetry C(18) column (150 mm x 3.9 mm, particle size 5 microm) with reverse-phase isocratic using mobile phase of 70:30 (v/v) acetonitrile: 2 mM ammonium acetate aqueous solution containing 0.01% formic acid (v/v) at a flow rate of 1.0 mL/min. A Waters symmetry C(18) guard column (20 mm x 3.9 mm, particle size 5 microm) was connected prior to the analytical column, and a guard column back wash was performed to reduce the analytical column contamination using a mixture of tetrahydrofuran (THF), methanol and water (45:45:10, v/v/v). The analytical run was 4 min. The use of a 96-well plate autosampler allowed a batch size up to 73 study samples. A triple-quadrupole mass spectrometer was operated in a positive ion mode and multiple reaction monitoring (MRM) was used for drug quantification. The method was validated over the concentration ranges of 19-5,300 ng/mL for lopinavir and 11-3,100 ng/mL for ritonavir. A-86093 was used as an internal standard (I.S.). The relative standard deviation (RSD) were <6% for both lopinavir and ritonavir. Mean accuracies were between the designed limits (+/-15%). The robust and rapid LC/MS/MS assay has been successfully applied for routine assay to support bioavailability, bioequivalence, and pharmacokinetics studies.  相似文献   

14.
A selective, rapid and simple liquid chromatography-tandem mass spectrometry (LC-MS/MS) method is described for assay of donepezil in human plasma using escitalopram as an internal standard. Chromatographic separation was achieved on a Betabasic-C(8), 5 microm, 100 x 4.6 mm column using methanol:water:formic acid (90:9.97:0.03, v/v/v) as mobile phase. Detection of donepezil and internal standard was achieved by ESI MS/MS in positive ion mode using 380.20/91.10 and 325.13/262.00 transitions, respectively. The linearity over the concentration range of 0.15-50 ng/mL for donepezil was obtained and the lower limit of quantification was 0.15 ng/mL. For each level of quality control samples, inter-day and intra-day precisions (RSD) were < or =8.92 and 10.35% and accuracy (%RE) were < or =7.33% and 9.33%, respectively. The recovery was more than 88.50% for both donepezil and internal standard by solid-phase extraction, eliminating evaporation and reconstitution steps.  相似文献   

15.
A sensitive and selective method for the determination of long-acting released octreotide in human plasma has been developed based on liquid chromatography/tandem mass spectrometry (LC/MS/MS). Octreotide and the internal standard, triptorelin, were precipitated from the matrix, washed with dichloromethane and subsequently separated by reversed-phase high-performance liquid chromatography (HPLC) employing a 1% formic acid/methanol gradient system. Detection was by electrospray ionization mass spectrometry in the positive ion mode using multiple-reaction monitoring. The assay was linear in the concentration range 0.0500-50.0 ng/mL with intra- and inter-day precision (as relative standard deviation) of <2.95% and <8.37%, respectively. The limit of detection was 0.0200 ng/mL. The method was applied to a pharmacokinetic study of long-acting released octreotide in healthy volunteers given an intramuscular injection containing 20 mg octreotide.  相似文献   

16.
A sensitive and specific liquid chromatography/tandem mass spectrometry (LC/MS/MS) method was developed for the investigation of the pharmacokinetics of 20(R)-ginsenoside Rg3 in dog. The plasma samples were pretreated by liquid-liquid extraction and analyzed using LC/MS/MS with an electrospray ionization interface. Dioscin was used as the internal standard. The method had a lower limit of quantitation of 0.5 ng/mL for Rg3 in 200 microL of plasma or 2 ng/mL in 100 microL of plasma, which offered a satisfactory sensitivity for the determination of Rg3 in plasma. The intra- and inter-day precisions were measured to be below 8% and accuracy between -1.5 and 1.4% for all quality control samples. This quantitation method was successfully applied to pharmacokinetic studies of Rg3 after both an oral and an intravenous administration to beagle dogs. No Rh2 and protopanaxadiol were detected in plasma.  相似文献   

17.
An analytical method for the determination of bisoprolol in human plasma has been developed based on liquid chromatography-tandem mass spectrometry (LC-MS/MS). The analyte and internal standard (IS) diphenhydramine were cleaned up by protein precipitation with acetonitrile, reconstituted in mobile phase and separated by reversed-phase high-performance liquid chromatography (HPLC) using methanol:10 mm ammonium acetate:formic acid (70:30:0.1 v/v/v) as mobile phase. Detection was carried out by multiple reaction monitoring (MRM) on an LC-MS/MS system and was completed within 2.5 min. The assay was linear over the range 0.5-100 ng/mL with a limit of quantitation (LOQ) of 0.5 ng/mL. The intra- and inter-day precision levels were within 5.54 and 9.95%, respectively, while the accuracy was in the range 89.4-113%. This method has been utilized in a pharmacokinetic study, where healthy volunteers were treated with an oral dose of 5 mg bisoprolol.  相似文献   

18.
A high-throughput ultrasensitive analytical method based on liquid chromatography with positive ion atmospheric pressure chemical ionization (APCI) coupled to tandem mass spectrometric detection (LC/MS/MS) was developed for the determination of all-trans-4-oxo-retinoic acid (at4oxoRA), 13-cis-4-oxo-retinoic acid (13c4oxoRA), 13-cis-retinoic acid (13cRA), all-trans-retinoic acid (atRA) and all-trans-retinol (atROH) in human plasma. A stable isotope of atRA was used as internal standard (IS). The analytes and IS were isolated from 100 microL plasma by acetonitrile mono-phase extraction (MPE) performed in black 96-well microtiterplates. A 100 microL injection was focused on-column and chromatographed on an Agilent ZORBAX SB-C18 rapid-resolution high-throughput (RRHT) column with 1.8-microm particles (4.6 mmx50 mm) maintained at 60 degrees C. The initial mobile phase composition was acetonitrile/water/formic acid (10:90:0.1, v/v/v) delivered at 1.8 mL/min. Elution was accomplished by a fast gradient to acetonitrile/methanol/formic acid (90:10:0.1, v/v/v). The method had a chromatographic total run time of 7 min. An Applied Biosystems 4000 Q TRAP linear tandem mass spectrometer equipped with a heated nebulizer (APCI) ionization source was operated in multiple reaction monitoring (MRM) mode with the precursor-to-product ion transitions m/z 315.4-->297 (4-oxo-retinoic acids), 301.2-->205 (retinoic acids), 305.0-->209 (IS) and 269.2-->93 (retinol) used for quantification. The assay was fully validated and found to have acceptable accuracy, precision, linearity, sensitivity and selectivity. The mean extraction recoveries from spiked plasma samples were 80-105% for the various retinoids at three different levels. The intra-day accuracy of the assay was within 8% of nominal and intra-day precision was better than 8% coefficient of variance (CV) for retinoic acids. Inter-day precision results for quality control samples run over a 12-day period alongside clinical samples showed mean precision better than 12.5% CV. The limit of quantification was in the range of 0.1-0.2 ng/mL and the mass limit of detection (mLOD) was in the range 1-4 pg on column for the retinoic acids. The assay has been successfully applied to the analysis of 1700 plasma samples.  相似文献   

19.
A new liquid chromatographic/mass spectrometric assay has been developed for the determination of DX-8951, a new anti-tumor drug, and its 4-hydroxymethyl metabolite (UM-1) in human plasma and urine. Solid-phase extractions were used for sample preparation. A gradient reverse-phase HPLC separation was developed with mobile phases consisting of trifluoroacetic acid and methanol. The detection was conducted using atmospheric pressure chemical ionization tandem mass spectrometry in the selected reaction monitoring mode. A structural analog, camptothecin (CPT), was used as the internal standard. The assay was validated for the determination of DX-8951 and UM-1 in human plasma and urine. The lower limits of quantitation of DX-8951 and UM-1 were 0.1 ng/mL in plasma and 1 ng/mL in urine. The method showed a satisfactory sensitivity, precision, accuracy, recovery and selectivity.  相似文献   

20.
A sensitive microElution solid-phase extraction (SPE) liquid chromatography/tandem mass spectrometry (LC/MS/MS) method has been developed and validated for the determination of M+4 stable isotope labeled cortisone and cortisol in human plasma. In this method, M+4 cortisone and M+4 cortisol were extracted from 0.3 mL of human plasma samples using a Waters Oasis HLB 96-well microElution SPE plate using 70 microL methanol as the elution solvent, and chromatographed on a Waters Symmetry C18 column (4.6 x 50 mm, 3.5 microm). M+9 cortisone and M+9 cortisol were used as the internal standards. A PE Sciex API 4000 tandem mass spectrometer interfaced with the liquid chromatograph via a turboionspray source was used for mass analysis and detection. The selected reaction monitoring (SRM) of precursor --> product ion transitions were monitored at m/z 365.2 [M+H](+) --> 167.0 and at m/z 367.3 [M+H](+) --> 125.1 for M+4 cortisone and M+4 cortisol, respectively. The lower limit of quantitation was 0.1 ng mL(-1) and the linear calibration range was from 0.1 to 100 ng mL(-1) for both analytes. This method demonstrated to be very reproducible and reliable.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号