首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
The potential of gas chromatography coupled to tandem mass spectrometry (GC/MS/MS) with a triple quadrupole analyzer (QqQ) has been investigated for the quantification and reliable identification of sixteen polycyclic aromatic hydrocarbons (PAHs) from the EPA priority list in animal and vegetable samples from aquaculture activities, whose fat content ranged from 5 to 100%. Matrices analyzed included fish fillet, fish feed, fish oil and linseed oil. Combining optimized saponification and solid‐phase extraction led to high efficiency in the elimination of interfering compounds, mainly fat, from the extracts. The developed procedure minimized the presence of these interfering compounds in the extracts and provided satisfactory recoveries of PAHs. The excellent sensitivity and selectivity of GC/(QqQ)MS/MS in selected reaction monitoring (SRM) allowed to reach limits of detection at pg/g levels. Two SRM transitions were acquired for each analyte to ensure reliable identification of compounds detected in samples. Confirmation of positive findings was performed by GC coupled to high‐resolution time‐of‐flight mass spectrometry (GC/TOFMS). The accurate mass information provided by GC/TOFMS in full acquisition mode together with its high mass resolution makes it a powerful analytical tool for the unequivocal confirmation of PAHs in the matrices tested. The method developed was applied to the analysis of real‐world samples of each matrix studied with the result of detecting and confirming the majority of analytes at the µg/kg level by both QqQ and TOF mass spectrometers. Copyright © 2009 John Wiley & Sons, Ltd.  相似文献   

2.
Summary Analytical protocols have been adapted for the study of hydrocarbons at the trace level in the environment. Various samples, including sediments and biota, were collected from the Kuwaiti environment, treated according to the protocol and analyzed by chromatographic and spectroscopic methods. The methods used were synchronous scanning fluorescence spectroscopy (SSFS); high-performance liquid chromatography (HPLC) on C18 reversed-phase and NH2 normal-phase columns with UV and fluorescence detectors; gas chromatography on fused-silica capillary columns (GC) with flame ionization detector (FID), mass spectrometer (MS) and flame photometric detector (FPD); and high-resolution molecular spectrofluorimetry in Shpol'skii matrix at 10 K (HRSS). The different methods were found to give complementary information. SSFS was useful for fast evaluation and preliminary assessment of oil pollution during extended programs; it permitted sample selection for deeper analyses but, when applied to biota, needed special care in the clean-up procedure. GC/FID, was used to analyze saturated and ethylenic compounds and was useful for obtaining information on the origin of hydrocarbons but inconvenient for analyzing the aromatic fraction. GC/FPD was difficult to use with sediment samples and yielded little information on biota samples, although it did permit confirmation of high oil contamination in some examples. HPLC on a normal-phase column with UV and fluorescence detectors was useful for the fractionation of samples and for the separation of different families of aromatic compounds according to aromatic carbon number. GC/MS was used to quantify polycyclic aromatic hydrocarbons (PAHs) of less than four cycles but was not sensitive enough for PAHs of higher molecular weight. HRSS, however, was useful for the quantification of heavy PAHs and was also faster, could be automated, and gave accurate results. However, in an oil-pollution study, it must be backed up by the other techniques. In fact, no single analytical technique was found to be sufficient, and only judicious combinations of the tested techniques yielded adequate information on the origin of hydrocarbons in the environment.  相似文献   

3.
This study describes the determination of polycyclic aromatic hydrocarbons (PAHs) in water using high-performance liquid chromatography (HPLC) coupled with fluorescence detection (FLD). Because individual PAHs are generally present in water only at trace levels, a sensitive and accurate determination technique is essential. The separation and detection of five PAHs were run completely within 25 min by the HPLC/FLD system with an analytical C18 column, a fluorescence detection, and acetonitrile-water gradient elution. Calibration graphs were linear with very good correlation coefficients (r > 0.9998), and the detection limits were in the range of 2-6 ng/l for five PAHs. Solid phase microextraction (SPME) was performed for sample pretreatment prior to HPLC-FLD determination, and the governing parameters were investigated. Compared to conventional methods, SPME has high recovery, saves considerable time, and reduces solvents waste. The extraction efficiencies of five PAHs were above 88% and the extraction times were 35 min in one pretreatment procedure. One particular discovery is that 1.5 M sodium monochloroactate (ClCH2COONa) can improve the extraction yield of PAH compounds more than other inorganic salts. The SPME-HPLC-FLD technique provides a relatively simple, convenient, practical procedure, which was here successfully applied to determine five PAHs in water from authentic water samples.  相似文献   

4.
Application of high-performance liquid chromatography (HPLC) and tandem mass spectrometry (MS/MS) for detection of aldehydes in biological samples such as blood, yoghurt, and milk, is reported. Sample preparation is easy, and the presented method is both sensitive and selective. It is based on the widely used dinitrophenylhydrazine derivatization, followed by extraction with n-hexane and a simple reversed-phase HPLC separation. Detection is performed by atmospheric pressure chemical ionization (APCI) in negative ion mode, with detection limits in the low picogram range. Using MS/MS, acetone and propionaldehyde can clearly be distinguished, facilitating propionaldehyde quantitation even in the presence of high acetone levels. Quantitation by direct MS/MS is also feasible, well suited for high-throughput applications, although not as accurate as using HPLC/MS/MS.  相似文献   

5.
The determination of polycyclic aromatic hydrocarbons (PAHs) using high-performance liquid chromatography (HPLC) with UV and fluorescence detection has been well established. Although most of the PAHs can be detected by these methods, some environmentally important polyaromatic compounds, such as acenaphthylene, do not show fluorescence and can only be determined by UV detection at higher concentrations. A sensitive and selective determination of acenaphthylene, acenaphthene and the six PAHs listed in the TVO, the German drinking water standard, is also possible by amperometric detection following HPLC separation. The method was applied to the determination of PAHs in different water samples after solid-phase extraction (SPE). The efficiency of the amperometric determination was found to be superior to UV detection (λ = 300 nm).  相似文献   

6.
Midazolam concentrations in patients' plasma was determined after extraction with high performance liquid chromatography (HPLC), gas chromatography (GC) and gas chromatography/mass spectrometry (GC/MS). GC was selected for routine plasma assays in terms of selectivity, simplicity, precision, accuracy and sensitivity (0.02 microgram/mL); HPLC analysis was less sensitive (0.1 microgram/mL) than GC; GC/MS was used for analysis validation. Plasma protein binding of midazolam was determined by GC in patients' plasma after in vitro incubation with midazolam, ultrafiltration and extraction; 5% of the drug was unbound to plasma proteins. Midazolam distribution in lipoprotein fractions separated by ultracentrifugation of plasma obtained from patients on prolonged midazolam treatment was also assayed by GC.  相似文献   

7.
European food legislation defines a set of 16 polycyclic aromatic hydrocarbons (PAHs) as of high concern for human health. The EU set contains structurally very similar PAHs with ring numbers between 4 and 6, and so raises some separation aspects and problems, which were not experienced with traditionally analysed PAHs. Many of the currently applied gas chromatographic mass spectrometric (GC-MS) methods suffer from separation problems, while high performance liquid chromatography with fluorescence detection (HPLC-FLD) is neither capable of detecting the whole set of EU priority PAHs nor does it (compared to GC-MS) allow structural identification. In addition HPLC-FLD shows limitations with difficult matrices due to interferences. The aim of this paper is to fill this gap by describing a liquid chromatographic dopant assisted atmospheric pressure photo ionisation tandem mass spectrometric (LC-DA-APPI-MS/MS) method for the determination of 15+1 EU priority PAHs in edible oil, which complies with the requirements set by European food legislation. Measurements were performed in positive ion mode. Anisole at a flow rate of 30 μl/min was used as dopant. Sample preparation was performed offline by donor-acceptor complex chromatography (DACC). Compared to HPLC-FLD methods the presented method enables the determination of all 15+1 EU priority PAHs at the low μg/kg concentration range including less fluorescence active compounds like benzo[j]fluoranthene and indeno[1,2,3-cd]pyrene. By analysing four reference materials it could be demonstrated that this method provides accurate results and is sufficiently sensitive for food control purposes. Statistically significant differences between the reference values and the measured analyte contents were not found. The method performs well also for very complex samples. Repeatability relative standard deviations (RSDr) of the determination of the target PAHs in olive oil were for most analytes below 5%. The limit of detection (LOD) of the method met the requirement set by EU legislation (0.3 μg/kg).  相似文献   

8.
A sensitive and selective method for the simultaneous determination of a spectrum of trichothecenes in residuals of biogas production has been developed. It comprises sample clean-up by liquid/liquid partition for digested manure and solid phase extraction for digested solid phase. Quantification of A- and B-type trichothecenes as their trifluoroacetyl derivatives is performed by gas chromatography mass spectrometry (GC/MS), that of B-type trichothecenes alternatively by high-performance liquid chromatography (HPLC). Fluorescence detection (FLD) after post-column derivatisation using methylacetoacetate and ammonium acetate after alkaline decomposition of toxins was applied. Detection limits in digestates were between 1 and 30 microg/l and 20 and 50 microg/l for GC/MS and HPLC/FLD, respectively. Recovery rates were between 52 and 129% for GC/MS detection with the exception of T-2 tetraol with 22%, and between 56 and 123% for HPLC/FLD.  相似文献   

9.
 A method for the determination of theophylline (TH), without derivatization, in serum by isotope dilution mass spectrometry using labelled [1, 3-15N2-2-13C]theophylline (LTH) as internal standard is described. After deproteinization, the analyte is directly injected into a high performance liquid chromatography – mass spectrometer operating with atmospheric-pressure chemical-ionization (APCI HPLC/MS). The concentrations of TH in sera measured by APCI HPLC/MS are compared with results from gas chromatography – isotope dilution mass spectrometry (GC-ID/MS), high performance liquid chromatography (HPLC) and fluorescence polarization immunoassay (FPIA). The accuracy, precision and recovery of the APCI HPLC/MS and GC-ID/MS methods are discussed. The coefficient of variation (CV) determined from duplicate samples was less than 2%. The detection limit was 10 ng/ml at a signal-to-noise ratio of 3:1. Received: 17 January 1996/Revised: 26 March 1996/Accepted: 5 April 1996  相似文献   

10.
The aim of this work is to establish a sensitive and reliable method for the analysis of the 16 priority Environmental Protection Agency-defined polycyclic aromatic hydrocarbons (PAHs) found in water samples. Gas chromatography (GC)-mass spectrometry (MS) and high-performance liquid chromatography (HPLC)-fluorescence detection (FLD)-UV techniques are optimized to obtain an adequate resolution of all compounds. Validation of the methods is carried out, and a good performance is observed for both techniques. The HPLC-FLD-UV technique is somewhat more sensitive than the GC-MS technique for the determination of PAHs; thus, the HPLC-FLD-UV method is used to follow up both the solid-phase extraction (SPE) analysis using cartridges and discs and the liquid-liquid extraction (LLE), which are also evaluated for the extraction of the PAHs. Low recoveries between 43% and 79% are obtained using SPE cartridges, and higher values are obtained using SPE discs (56-96%) and LLE (60-105%). Better results are obtained using the LLE technique, and, thus, analysis of real water samples is carried out using this technique. LODs between 0.6 and 21 ng/L and relative standard deviations less than 15% are obtained using a spiked water sample analyzed using the full LLE HPLC-FLD-UV method.  相似文献   

11.
The first part of this study first aims at validating a method to identify suspected allergens limited by EU regulations in fragrances by comprehensive two-dimensional gas chromatography (GC x GC) coupled with rapid scanning quadrupole MS (GC x GC-qMS). The effectiveness of the quadrupole MS operating at different scanning speed (1000 and 11,111 amu/s) was evaluated in identifying (full scan mode acquisition--TIC) and in quantifying (single ion monitoring--SIM) the target analytes in complex mixtures. In full scan acquisition mode the mass range was reduced to 40-240 amu to increase the scan acquisition rate while in SIM mode the influence of different dwell-times (40, 10 and 5 ms) was tested. The number of scans for each single modulated chromatographic GC x GC peak and the total number of scans for the 2D peak, together with half height peak width (referred to apex) of each allergen in the standard mixture in both TIC and SIM modes were determined. Moreover, the match quality of the spectra obtained by GC/MS at 1000 and 11,111 amu/s and by GC x GC-MS at 11,111 amu/s were compared and the occurrence of spectral skewing verified. In the second part of this work quantitative methods by GC x GC-SIM/qMS and GC x GC-FID were validated on the basis of Eurachem/CITAC protocols through which the following performance parameters were determined: confirmation of identity, selectivity and specificity, limit of detection (LOD), limit of quantitation (LOQ), linearity (working and linear range), precision and accuracy and uncertainty. Suspected allergens were spiked in a concentration range between 2 and 25 ppm (microg/mL) on a Test fragrance taken as a reference, while 1,4 dibromo-benzene and 4,4'-dibromodiphenyl were used as internal standards.  相似文献   

12.
色谱/质谱联用技术分析测定贻贝中的多环芳烃   总被引:5,自引:0,他引:5  
马永安  刘彤 《分析化学》1997,25(12):1382-1385
介绍了GC-MS联用技术-物质征离子选择法测定贻贝中多环芳烃的分析方法,并就定性定量离子的选择,以及方法的准确度和精密度进行了探讨。结果表明,本方法适用于海洋生物贻贝,牡蛎中PAHs的分析测定。  相似文献   

13.
The use of chloramphenicol (CAP)--a highly effective broad-spectrum antibiotic used in animal husbandry--is banned in many countries. Therefore, a very low minimum required performance limit (MRPL) of 0.3 microg/kg CAP in meat for human consumption has been defined. Analytical methods capable of quantifying and confirming such low residue levels require sophisticated instrumentation. Preferably sensitive liquid chromatography/tandem mass spectrometry (LC/MS/MS) or gas chromatography/mass spectrometry (GC/MS) methods have been used. This paper suggests the use of sub-2 microm particulate high-performance liquid chromatography (HPLC) columns to gain additional sensitivity and improve resolution as well as speed. Depending on the operating conditions, higher chromatographic resolution and speed can be obtained at the price of a significantly increased operating pressure, requiring dedicated LC equipment. A 3-4-fold overall improvement of the signal-to-noise ratio for CAP was obtained compared to more classical 5 microm particulate HPLC columns. The proposed analytical methodology includes an enzymatic digestion, which liberates glucuronide-bound CAP from kidney tissue. The extracts obtained after an Extrelut clean-up are sufficiently pure to permit routine injection of biological samples into the sub-2 microm particulate HPLC column, without observing rapid deterioration of peak shape or column clogging problems. The time for one chromatographic run was 4.2 min. The described method was validated for two particularly difficult matrices (kidney and honey). Decision limits (CC alpha) were 0.007 microg/kg (honey) und 0.011 microg/kg (kidney), which are significantly below the current MRPL.  相似文献   

14.
We report a selective, sensitive and fast liquid chromatography/tandem mass spectrometry (LC/MS/MS) method for the determination of diallyldimethylammonium chloride (DADMAC) in water. Hydrophilic interaction liquid chromatography (HILIC) was used to avoid ion-pairing reagents, which are generally employed to retain cationic compounds. The complementary information obtained in a triple quadrupole mass spectrometer and in an ion trap Orbitrap has been used to study the fragmentation of the DADMAC cation [M](+) and for the correct assignment of the products ions. The HILIC/MS/MS method developed, using electrospray ionization in positive ion mode and selected reaction monitoring (SRM) acquisition mode, led to a reliable determination and confirmation of the DADMAC cation in water samples down to 50 ng L(-1). The low detection limit achieved, in combination with the absence of matrix effects, allowed the direct analysis of samples without any pretreatment, preconcentration or clean-up step. DADMAC was determined in samples collected in a drinking water treatment plant (DWTP) in Barcelona (Spain) and it was found in the influent at the μg L(-1) level.  相似文献   

15.
This paper describes a new method for sensitive, specific and direct determination of domoic acid (DA), the causative toxin of amnesic shellfish poisoning (ASP) syndrome, in shellfish. It is based on combination of hydrophilic interaction liquid chromatography with mass spectrometry (HILIC/MS). The high percentage of organic modifier in the mobile phase and the omission of ion-pairing reagents, both favoured in HILIC, result in enhanced detection limits with MS detection. The new method was set up either on an ionspray ion trap MS instrument operating in MS and MS/MS scanning acquisition modes, or on a turboionspray triple-quadrupole MS system operating in selected ion monitoring (SIM) and multiple reaction monitoring (MRM) acquisition modes. Positive and negative ion experiments were performed. MRM experiments are recommended for screening contaminated shellfish tissue and for quantitative analyses due to highest sensitivity and selectivity. The minimum detection levels for the toxin in tissue were found to be 63 and 190 ng/g in positive and negative MRM experiments, respectively, which are well below the regulatory limit for DA in tissue (20 microg/g). Application to shellfish samples collected in the Adriatic Sea (Italy) in the period 2000-2004 demonstrated for the first time in Italy the presence of DA as a new toxin that has entered the Adriatic Mytilus galloprovincialis toxin profile.  相似文献   

16.
杨蕾  王保兴  侯英  杨燕 《色谱》2007,25(5):747-752
应用搅拌棒吸附萃取(SBSE)-热脱附(TDS)-气相色谱/质谱联用(GC/MS)方法测定了滇池水系(滇池和盘龙江上、中、下游)中16种多环芳烃(PAHs)的含量。方法快速简便,无有机溶剂污染,PAHs的最低检出限为1.0~468.8 pg,理论回收率在90%以上,加标回收率为83.1%~109.4%,相对标准偏差小于10%。测定结果表明,这16种多环芳烃在滇池水样中的含量为89.16 ng/L,在盘龙江上游水样中的含量为65.41 ng/L,在盘龙江中游水样中的含量为339.22 ng/L,而在盘龙江下游水样中的含量为62.25 ng/L,说明滇池水系已经受到一定的PAHs污染,加强对滇池、盘龙江中PAHs有机污染的控制势在必行。  相似文献   

17.
A reversed-phase high-performance liquid chromatography (RP-HPLC) method was developed and compared with a gas chromatography/mass spectrometry (GC/MS) method for determining butylated hydroxytoluene (BHT) in foodstuffs as a result of migration from plastic packaging. Similar extraction procedures were used in both methods. BHT was quantitated using an external standard in the HPLC method and an internal standard in the GC/MS method. Both methods presented good linearity (r(2) > or = 0.9917) and low detection limits. Recoveries obtained with the HPLC method (chicken meat, 95.8%, and Gouda cheese, 83.9%) were better than with the GC/MS method (chicken meat, 85.6%, and Gouda cheese, 71.3%).  相似文献   

18.
《Electroanalysis》2017,29(8):1887-1893
A sensitive anthracene (AN) sensor was developed with a gold electrode modified with a dendritic star‐copolymer film by in situ electrochemical co‐polymerization of generation 3 propylenethiophenoimine and 3‐hexylthiophene. The sensor's {Au/G3PPT‐co‐P3HT: i. e. gold‐generation 3 poly(propylenethiophenoimine)‐co‐poly(3‐hexylthiophene)} analytical response for anthracene was obtained by phase selective alternating current voltammetric (PSACV) signal transduction. An in‐phase angle of 0° yielded the most sensitive stripping signal and produced the best discrimination between the Faradaic and capacitive currents. The PSACV sensor exhibited a linear range (LR) of 3.48–56.4 nmol/L AN and a limit of detection (LOD) of 2.62 nmol/L AN. The LOD is comparable to the value of 4.4 nmol/L AN reported for glassy carbon electrode modified with graphenated polyaniline sensor. The low LOD value suggests that the AN sensor has promise for monitoring compliance to World Health Organisation (WHO) approved limit for polyaromatic hydrocarbons (PAHs) in wastewater (3.93 nmol/L). The Au/G3PPT‐co‐P3HT sensor is not as sensitive as gas chromatography coupled to tandem mass spectrometry (GC‐MS/MS) and reversed‐phase high performance liquid chromatography (RP‐HPLC) methods. However, the advantage of the PSACV signalling protocol is that real sample test results indicate that the sensor can be used for the determination of AN in oil‐polluted wastewater.  相似文献   

19.
Counter‐current chromatography (CCC) was investigated as a new sample pretreatment method for the determination of trace polycyclic aromatic hydrocarbons (PAHs) in water environmental samples. The experiment was performed with a non‐aqueous binary two‐phase solvent system composed of n‐heptane and acetonitrile. The CCC column was first filled with the upper stationary phase, and then a large volume of water sample was pumped into the column while the CCC column was rotated at 1600 rpm. Finally, the trace amounts of PAHs extracted and enriched in the stationary phase were eluted out by the lower mobile phase and determined by gas chromatography–flame ionization detector (GC‐FID) or gas chromatography–mass spectrometry (GC‐MS). The enrichment and cleanup of PAHs can be fulfilled online by this method with high recoveries (84.1–103.2%) and good reproducibility (RSDs: 4.9–12.2%) for 16 EPA PAHs under the optimized CCC pretreatment conditions. This method has been successfully applied to determine PAHs in lake water where 8 PAHs were detected in the concentration of 40.9–89.9 ng/L. The present method is extremely suitable for the preparation of large volume of environmental water sample for the determination of trace amounts of organic pollutants including PAHs as studied in this paper.  相似文献   

20.
A comparative study was carried out for the simultaneous determination of 11 pyrethroid insecticides in soil by gas chromatography (GC) - ion trap (IT)- mass spectrometry (MS), by means of two different ionization modes; electron impact and negative chemical ionization and three data acquisition procedures; full scan, selected ion monitoring and MS/MS. Pyrethroids investigated were tetramethrin, bifenthrin, phenothrin, λ-cyhalothrin, permethrin, cyfluthrin, cypermethrin, flucythrinate, esfenvalerate, fluvalinate and deltamethrin. Soil samples were treated with toluene/water by microwave-assisted extraction for 9 min at 700 W and a cleaning up with florisil was performed. Clean soil samples were spiked with pyrethroids at a spiking level of 10, 25 and 50 ng/g. The method employed provides a concentration factor of 10. The ionization gas employed in the negative chemical ionization mode was methane. The use of MS/MS acquisition, in electron impact ionization, provided the best results, due to its high selectivity and sensitivity, giving very low limits of detection from 0.08 to 0.54 ng/g. In negative chemical ionization full scan and selected ion monitoring methods detection limits from 0.12 to 1.40 ng/g were found. The proposed methods were applied to several levels from 10 to 50 ng/g of spiked soils, being electron impact MS/MS method which minimizes matrix spectrum interferences and provided recovery average values from 84% to 120% with relative standard deviations which varied from 3.2 to 7.2%.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号