首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
Molecular imprinting is a useful technique for the preparation of functional materials with molecular recognition properties. In this work, a biomimetic potentiometric sensor, based on a non-covalent imprinted polymer, was fabricated for the recognition and determination of hydroxyzine in tablets and biological fluids. The molecularly imprinted polymer (MIP) was synthesized by precipitation polymerization, using hydroxyzine dihydrochloride as a template molecule, methacrylic acid (MAA) as a functional monomer and ethylene glycol dimethacrylat (EGDMA) as a cross-linking agent. The sensor showed a high selectivity and a sensitive response to the template in aqueous system. The MIP-modified electrode exhibited a Nernstian response (29.4 ± 1.0 mV decade−1) in a wide concentration range of 1.0 × 10−6 to 1.0 × 10−1 M with a lower detection limit of 7.0 × 10−7 M. The electrode demonstrated a response time of ∼15 s, a high performance and a satisfactory long-term stability (more than 5 months). The method has the requisite accuracy, sensitivity and precision to assay hydroxyzine in tablets and biological fluids.  相似文献   

2.
分子印迹电位型传感器快速检测猪尿液中的克伦特罗   总被引:2,自引:0,他引:2  
梁荣宁  高奇  秦伟 《分析化学》2012,(3):354-358
以盐酸克伦特罗为模板分子,采用沉淀聚合法合成了克伦特罗的分子印迹聚合物,并以其为离子载体,制得分子印迹聚合物膜克伦特罗离子选择性电极。在最优实验条件下,电极对克伦特罗阳离子的检出限可达7.0×10-8mol/L,线性范围为1.0×10-7~1.0×10-4mol/L,能斯特斜率为55.7 mV/decade。此电极具有优越的选择性、快速的响应时间以及良好的稳定性;已成功应用于实际猪尿样品中克伦特罗的测定,加标回收率为98%~107%,检测时间小于3 min。  相似文献   

3.
A flow-injection biosensor-like system based on a nonenzymatic approach has been developed to determine the carbamate pesticide carbaryl in complex biological samples without lengthy and expensive extraction steps. Molecularly imprinted polymeric beads were used to immobilize carbaryl from biological samples. pH variation permitted the elution of carbaryl from the binding cavity to the flow cell. A pH electrode was used to detect changes in the charge of carbaryl in the sample solution resulting from the protonation and deprotonation of the molecule over different pH ranges. At pH 2.0, the secondary amine group is protonated, giving a (+1) charge to the carbaryl molecule. At pH 8.0, the ionized carbaryl loses a proton to become neutral, changing the local pH of the flow cell. The pH change at the flow cell generated by the deprotonation of carbaryl ion in alkaline medium was used to determine the carbaryl concentration. Parameters influencing the performance of the system were optimized for use in the detection procedure. The validated biosensor-like system had a carbaryl detection limit of 10.0 μg/mL and a response that was linear (r 2 > 0.98) over the concentration range of 10.0–00 μg/mL.  相似文献   

4.
In this work, a mefenamic acid (MFA) nanosensor was synthesized by the aid of molecularly imprinted polymer (MIP) technique. MIP layer was coated on magnetite nanoparticles as magnetic nano-carriers. Synthesized nanoparticles were characterized using various measurements techniques. Light scattering properties of the synthesized nanoparticles in the presence or absence of MFA have been selected as the detection signal. In this regard, resonance light scattering has been used as the detection method. Various factors that can potentially affect light scattering efficiency (i.e., pH, ultrasonication time and nanoparticle dosage) were optimized using “one-at-a-time” method. A linear dynamic range was established from 100.0 to 2000.0 ng L−1 of MFA and the limit of detection was found to be 50.0 ng L−1 using the proposed method.  相似文献   

5.
以分子印迹作为识别体,制成高灵敏度和高选择性的化学发光传感器在线检测牛肉与鸡肉组织中残留的磺胺嘧啶。磺胺嘧啶作为靶分子,通过悬浮聚合制备了1~10μm的分子印迹聚合物。将分子印迹聚合物装入聚四氟乙烯管中,作为固相萃取柱,并联在八通阀上,用于在线选择吸附磺胺嘧啶。在最佳条件下,测得磺胺嘧啶线性范围7.0×10–9~9.0×10–7g/mL,方法的检出限为(3σ)2×10–10g/mL,11次平行测定3.0×10–8g/mL的磺胺嘧啶溶液的化学发光强度相对标准偏差为3.4%。方法能够用于检测肉类产品中残留的磺胺嘧啶。  相似文献   

6.
Fenfluramine-imprinted polymer was prepared by self assembly with acrylic amide as functional monomer and ethylene glycol dimethacrylate as crosslinker. The binding characteristics of the imprinted polymer to fenfluramine were evaluated by equilibrium binding experiments and the morphology was studied by SEM. Taking the imprinted polymer as recognition material, using the new 3-p-nitrylphenyl-5-(4′-methyl-2′-sulfonophenylazo)rhodanine (M4NRASP) synthesized by the authors as chemiluminescence reagent, a new highly selective flow injection chemiluminescence sensor for trace fenfluramine with good sensitivity was established which utilized the chemiluminescence reaction between fenfluramine, M4NRASP, and potassium permanganate in hydrochloric acid. The traditional flow-through cell was replaced with a polymethyl methacrylate module, with Y-shaped flow path, through which the above three reactants were injected simultaneously. Under optimum conditions the relative chemiluminescence intensity shows a linear relationship with the concentration of fenfluramine over the range of 5×10–7 to 8×10–6 g/mL with a lower detection limit of 3.4×10–8 g/mL. The relative standard deviation for the determination of 1.0×10–6 g/mL fenfluramine solution was 2.4% (n = 11). This proposed sensor could be satisfactorily applied to the determination of fenfluramine in weight-reducing capsules.  相似文献   

7.
制备了白藜芦醇的分子印迹聚合物,用聚四氟乙烯管作为微固相萃取柱,连接在流动注射系统的八通阀上,对白藜芦醇进行富集和分离;经甲醇和乙酸混合洗脱液(9:1,V/V)在线洗脱后与酸性KMnO4发生化学发光反应.测定白藜芦醇的线性范围2.5×10-7~6.1×10-5g/mL,方法的检出限为(3σ)8×10-8g/mL,11次...  相似文献   

8.
An on-line supported liquid membrane-piezoelectric detection system, based on a molecularly imprinted polymer (SLM-QCM-MIP) manifold, has been developed and applied to the quantitative determination of vanillin in food samples. The analyte is extracted from a donor phase into the hydrophobic membrane, and then back extracted into a second aqueous phase used as the acceptor solution. The quantification of vanillin was performed using a quartz crystal microbalance modified with a molecularly imprinted polymer (MIP). The method shows a linear range between 5 and 65 μM, with a relative standard deviation of ±4.8% (at 5 μM). The method was validated by analysing food samples and comparing the results with an SLM based on spectrophotometric quantification.  相似文献   

9.
Despite the increasing number of applications of molecularly imprinted polymers (MIPs) in analytical chemistry, the construction of a biomimetic potentiometric sensor remains still challenging. In this work, a biomimetic potentiometric sensor, based on a non‐covalent imprinted polymer was fabricated for the recognition and determination of cetirizine. The MIP was synthesized by precipitation polymerization, using cetirizine dihydrochloride as a template molecule, methacrylic acid (MAA) as a functional monomer and ethylene glycol dimethacrylate (EGDMA) as a cross linking agent. The sensor showed high selectivity and a sensitive response to the template in aqueous system. The MIP‐modified electrode exhibited Nernstian response (28.0±0.9 mV/decade) in a wide concentration range of 1.0×10?6 to 1.0×10?2 M with a lower detection limit of 7.0×10?7 M. The electrode has response time of ca. 20 s, high performance, high sensitivity, and good long term stability (more than 5 months). The method was satisfactory and used to the cetirizine assay in tablets and biological fluids.  相似文献   

10.
An original electrochemical sensor based on molecularly imprinted conducting polymer (MICP) is developed, which enables the recognition of a small pesticide target molecule, atrazine. The conjugated MICP, poly(3,4-ethylenedioxythiophene-co-thiophene-acetic acid), has been electrochemically synthesized onto a platinum electrode following two steps: (i) polymerization of comonomers in the presence of atrazine, already associated to the acetic acid substituent through hydrogen bonding, and (ii) removal of atrazine from the resulting polymer, which leaves the acetic acid substituents open for association with atrazine. The obtained sensing MICP is highly specific towards newly added atrazine and the recognition can be quantitatively analyzed by the variation of the cyclic voltammogram of MICP. The developed sensor shows remarkable properties: selectivity towards triazinic family, large range of detection (10−9 mol L−1 to 1.5 × 10−2 mol L−1 in atrazine) and low detection threshold (10−7 mol L−1).  相似文献   

11.
以丙烯酰胺为功能单体,葛根素为模板分子,马来松香丙烯酸乙二醇酯为交联剂,采用循环伏安法合成了葛根素分子印迹膜,并以此为识别元件制备了葛根素电化学传感器。该传感器对葛根素具有高度的选择性和良好的敏感度,葛根素氧化峰电流与其浓度在6.0×10-8~1.6×10-3mol/L范围内呈良好的线性关系,检出限为2.0×10-8mol/L。将此传感器用于葛根素注射液和木瓜葛根片中葛根素的含量测定,回收率为97.7%~106.4%。  相似文献   

12.
A piezoelectric quartz sensor coated with molecularly imprinted polymer (MIP) for caffeine was developed. The MIP was prepared by co-polymerizing methacrylic acid (MAA) and ethylene glycol dimethacrylate (EDMA) in the presence of azobis(isobutyronitrile) as initiator, caffeine as template molecule, and chloroform as solvent. The MIP suspension in polyvinyl chloride/tetrahydrofuran (6:2:1 w/w/v) solution was spin coated onto the surface of the electrode of a 10 MHz AT-cut quartz crystal. The sensor exhibited a linear relationship between the frequency shift and caffeine concentration in the range of 1×10–7 mg mL–1 up to 1x10–3 mg mL–1 [correlation coefficient (r)=0.9935] in a stopped flow measurement mode. It has a sensitivity of about 24 Hz/ln(concentration, mg mL–1). A steady-state response was achieved in less than 10 min. The performance characteristic of the sensor shows a promising and inexpensive alternative method of detecting caffeine. Surface studies were carried out for the reagent phase of the sensor using SEM, AFM, and XPS analysis in order to elucidate the imprinting of the caffeine molecule. The SEM micrograph, AFM image, and XPS spectra confirmed the removal of caffeine by Soxhlet extraction in the imprinting process and the rebinding of caffeine to the MIP sensing layer during measurement.  相似文献   

13.
Highly sensitive flow-injection chemiluminescence (CL) combined with molecularly imprinted solid-phase extraction (MISPE) has been used for determination of 2,4-dichlorophenol (2,4-DCP) in water samples. The molecularly imprinted polymer (MIP) for 2,4-DCP was prepared by non-covalent molecular imprinting methods, using 4-vinylpyridine (4-VP) and ethylene glycol dimethacrylate (EGDMA) as the monomer and cross-linker, respectively. 2,4-DCP could be selectively adsorbed by the MIP and the adsorbed 2,4-DCP was determined by its enhancing effect on the weak chemiluminescence reaction between potassium permanganate and luminol. The enhanced CL intensity was linear in the range from 1 × 10−7 to 2 × 10−5g mL−1. The LOD (S/N = 3) was 1.8 × 10−8g mL−1, and the relative standard deviation (RSD) was 3.0% (n = 11) for 1.4 × 10−6g mL−1. The proposed method had been successfully applied to the determination of 2,4-DCP in river water. Figure Effect of 4-VP content on the ultraviolet spectrum of 2,4-DCP in chloroform  相似文献   

14.
A sensitive electrochemical molecularly imprinted sensor was developed for the detection of glyphosate (Gly), by electropolymerisation of p-aminothiophenol-functionalised gold nanoparticles in the presence of Gly as template molecule. The extraction of the template leads to the formation of cavities that are able to specifically recognise and bind Gly through hydrogen bonds between Gly molecules and aniline moieties. The performance of the developed sensor for the detection of Gly was investigated by linear sweep voltammetry using a hexacyanoferrate/hexacyanoferrite solution as redox probe, the electron transfer rate increasing when concentration of Gly increases, due to a p-doping effect. The molecularly imprinted sensor exhibits a broad linear range, between 1 pg/L and 1 µg/L and a quantification limit of 0.8 pg/L. The selectivity of the proposed sensor was investigated towards the binding of Gly metabolite, aminomethylphosphonic acid, revealing excellent selectivity towards Gly. The developed sensor was successfully applied to detect Gly in tap water samples.  相似文献   

15.
Yang Y  Long Y  Cao Q  Li K  Liu F 《Analytica chimica acta》2008,606(1):92-97
Bilirubin (BR) imprinted polymer was successfully prepared using supramolecular host compound β-cyclodextrin (β-CD) as functional monomer. The adsorption equilibrium was attained in about 4 h, which indicated that the adsorption kinetics was comparatively fast. The results of adsorption and selectivity experiments indicated that BR-imprinted β-CD polymer was able to bind BR specifically and reversibly. The specific recognition of BR-imprinted β-CD polymer for BR may be due to the cooperative effects of inclusion interaction and hydrogen bonding. This BR-imprinted β-CD polymer was further applied to eliminate BR in human serum sample. It was verified that the binding specificity of the BR-imprinted polymer for BR was essentially sufficient in the presence of other compounds coexisting in serum sample. Therefore, as a reusable material possessing high affinity and selectivity, BR-imprinted β-CD polymer has a potential application perspective as a clinical hemoperfusion material.  相似文献   

16.
A new molecularly imprinted polymer (MIP)–chemiluminescence (CL) imaging detection approach towards chiral recognition of dansyl-phenylalanine (Phe) is presented. The polymer microspheres were synthesized using precipitation polymerization with dansyl-l-Phe as template. Polymer microspheres were immobilized in microtiter plates (96 wells) using poly(vinyl alcohol) (PVA) as glue. The analyte was selectively adsorbed on the MIP microspheres. After washing, the bound fraction was quantified based on peroxyoxalate chemiluminescence (PO-CL) analysis. In the presence of dansyl-Phe, bis(2,4,6-trichlorophenyl)oxalate (TCPO) reacted with hydrogen peroxide (H2O2) to emit chemiluminescence. The signal was detected and quantified with a highly sensitive cooled charge-coupled device (CCD). Influencing factors were investigated and optimized in detail. Control experiments using capillary electrophoresis showed that there was no significant difference between the proposed method and the control method at a confidence level of 95%. The method can perform 96 independent measurements simultaneously in 30 min and the limits of detection (LODs) for dansyl-l-Phe and dansyl-d-Phe were 0.025 μmol L−1 and 0.075 μmol L−1 (3σ), respectively. The relative standard deviation (RSD) for 11 parallel measurements of dansyl-l-Phe (0.78 μmol L−1) was 8%. The results show that MIP-based CL imaging can become a useful analytical technology for quick chiral recognition.  相似文献   

17.
This work shows developing conductometric sensor based on molecularly imprinted polymer (MIP) for the screening of complex mixture of haloacetic acids (HAAs) in drinking water. The recognition of the HAAs was achieved by trichloroacetic acid (TCAA)-imprinted polymers synthesised from the copolymerization of 4-vinylpyridine (4-VPD) and ethylene glycol dimethacrylate (EDMA) in the presence of the TCAA template in acetonitrile, either by bulk polymerization (BP) method or by a multi-step swelling polymerization (MSP) method. TCAA-imprinted polymer of both methods was tested for re-binding with the template and its analogs. It was found that these polymers could bind selectively to the template molecule and HAA derivatives. HAA measurements were carried out by the application of the polyvinyl chloride membrane fabricated with TCAA-imprinted polymer on conductometric sensors. The technological parameters (operating frequency, membrane composition, ionic strength and medium pH) for the sensors were identified and optimised in respect to the response to TCAA, using sensor fabricating with BP-based MIP as a model. The selectivity of the sensors constructed with MIPs made by either that of the two imprinting methods was also investigated, which the influence of the method of imprinting on the binding strength and selectivity of the recognition element embedded in sensor was observed. The sensors showed high sensitivity and selectivity for the response toward TCAA, the sensor modified with MSP-based MIP being better. In addition, the sensors, particularly when was constructed with MSP-based MIP exhibited good cross-reactivities with a wide range of HAAs, which is useful for the screening of the group of HAA usually present in chlorinated water in complex mixtures. Thus, the sensor modified with MSP-based MIP was chosen for analytical application. The calibration of this sensor was determined, showing the good linear graphs (R2>0.970) for HAAs over the concentration range of 25-1000 μg/l and the detection limit of each HAA in the range 0.2-5.0 μg/l. Moreover, the results in real analysis of the sensor indicate the simplicity and reliability of the method. The present work demonstrated that the sensor based on TCAA-imprinted polymer is a fast and sensitive screening method of HAAs in drinking water.  相似文献   

18.
The proposed L ‐histidine sensing system composed of a molecularly imprinted solid‐phase microextraction component combined with a molecularly imprinted polymer sensor was used to determine critical levels of test analyte in a complex matrix of highly diluted human blood serum without any non‐specific sorption and false‐positive contributions. The molecularly imprinted polymer was a zwitterionic polymer brush derived from the disodium salt of EDTA and chloranil, grafted to solid‐phase microextraction material. The hyphenated approach was able to detect L ‐histidine quantitatively with a limit of detection as low as 0.0435 ng/mL (RSD = 0.2%, S/N = 3).  相似文献   

19.
A novel molecularly imprinted polymer solid-phase extraction (MISPE) with flow-injection chemiluminescence (CL) was developed for the determination of pazufloxacin mesilate (PZFX). The molecularly imprinted polymer (MIP) was synthesized by using PZFX as the imprinting molecule. A glass tube packed the particles of the MIP was employed as MISPE micro-column, which was connected into the sampling loop of the eight-way injection valve for on-line selective preconcentration and extraction of PZFX. The eluent of acetonitrile:acetic acid (9:1, v:v) was used as carrier for eluting the adsorbed PZFX to react with the mixture of cerium(IV) and sodium sulfite in the flow cell to produce strong CL. The relative intensity of CL was linear to PZFX concentration in the range from 2.5 × 10−9 to 2.5 × 10−7 g mL−1. The limit of detection was 7 × 10−10 g mL−1 (3 σ) and the relative standard deviation for 5 × 10−8 g mL−1of PZFX solution was 3.7% (n = 7). This method has been applied to the determination of PZFX in human urine.  相似文献   

20.
This paper reports the synthesis and testing of a molecularly imprinted polymer membrane for digoxin analysis. Digoxin-specific bulk polymer was obtained by the UV initiated co-polymerisation of methacrylic acid and ethylene glycol dimethacrylate in acetonitrile as porogen. After extracting the template analyte, the ground polymer particles were mixed with plasticizer polyvinyl chloride to form a MIP membrane. A reference polymer membrane was prepared from the same mixture of monomers but with no template. The resultant membrane morphologies were examined by scanning electron microscopy. The imprinted membrane was tested as the recognition element in a digoxin-sensitive fluorescence sensor; sensor response was measured using standard solutions of digoxin at concentrations of up to 4 × 10−3 mg L−1. The detection limit was 3.17 × 10−5 mg L−1. Within- and between-day relative standard deviations RSD (n = 5) were in the range 4.5-5.5% and 5.5-6.5% respectively for 0 and 1 × 10−3 mg L−1 digoxin concentrations. A selectivity study showed that compounds of similar structure to digoxin did not significantly interfere with detection for interferent concentrations at 10, 30 and 100 times higher than the digoxin concentration. This simply manufactured MIP membrane showed good recognition characteristics, a high affinity for digoxin, and provided satisfactory results in analyses of this analyte in human serum.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号