首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
An unmodified silica gel (Develosil 30-5) column (150×4.6 mm I.D.) has been applied to the ion chromatographic separation of alkali, alkaline earth and transition metal cations. The retention behavior of the above cations on the bare substrate was investigated using a number of weak inorganic and organic acid eluents. During this investigation, several separations were achieved and the most suitable eluent conditions were identified. It was concluded that: (a) 1.5 mM HNO3-0.5mM pyridine-2,6-dicar☐ylic acid eluent was the most effective for the simultaneous separation of common alkali and alkaline earth metal cations, (b) 1.5 mM oxalic acid eluent resulted in the best separation of alkali, alkaline earth, and transition metal cations, (c) 0.5 mM CuSO4 eluent could be used for the separation of alkali metal cations alone and (d) 0.5 mM ethylenediamine-oxalic acid eluent at pH 5.5 resulted in themost efficient separation of both alkaline earth and transition metal cations.  相似文献   

2.
The application of zirconium-modified silica gels (Zr-Silica) as stationary phases for ion-exclusion chromatography with conductimetric detection (IEC–CD) for C1–C8 aliphatic carboxylic acids (formic, acetic, propionic, butyric, valeric, caproic, heptanoic and caprylic acids) was carried out using pyromellitic acid as the eluent. Zr-Silicas were prepared by the reaction of the silanol group on the surface of silica gel with zirconium tetrabutoxide [Zr(OCH2CH2CH2CH3)4] in ethanol solution. An ASRS-Ultra anion self-regenerating suppressor in the K+ form was used for the enhancement of conductimetric detector response of these aliphatic carboxylic acids. A Zr-Silica adsorbed on 10 mg zirconium g−1 silica gel was the most suitable stationary phase in IEC–CD for the separation of these aliphatic carboxylic acids. Excellently simultaneous separation and highly sensitive detection for these aliphatic carboxylic acids were achieved in 25 min by IEC–CD with the Zr-Silica column (250×4.6 mm I.D.) and a 0.2 mM pyromellitic acid containing 0.15% heptanol as the eluent.  相似文献   

3.
We describe ion chromatography (IC) on open tubular cation exchange columns with a controllable capacity multilayered stationary phase architecture. The columns of relatively large bore (75 microm id) are fabricated by coating fused-silica capillaries with multiple layers of poly(butadiene-maleic acid) (PBMA) copolymer and crosslinking the deposited layers by thermally initiated radical polymerisation. Column capacity increases in a predictable manner with increase in the number of successively coated layers. Gravity flow with a modest head (< 2 m) can provide the desired separations within a reasonable period. We provide a minimalist configuration where no suppression is used, the sample is injected hydrodynamically as in CE, and detection is accomplished by an inexpensive homebuilt contactless conductivity detector or a capacitance to voltage digital converter. A 1 m long 75 microm bore column coated with two layers of PBMA allows gravity-flow open tubular IC to separate four alkali cations in < 10 min with a 1 mM tartaric acid (TA) eluent. Simultaneous separation of alkali and alkaline earth metal cations can be accomplished in less than 25 min using 1.75 mM pyridinedicarboxylic acid as an eluent. Contactless conductometric detection (C(4)D) allows LODs down to 150 nmol/L, corresponding to 30 fmol injections. Analysis of real water samples is demonstrated.  相似文献   

4.
The simultaneous separation of alkali and alkaline-earth cations on polybutadiene-maleic acid-coated silica columns can be achieved with mineral acid eluents. Simple ion-exchange retention mechanisms and the high selectivity of eluent hydronium ions towards the carboxylate group are the basis for the separation. Use of mineral acid eluents allows using this column in both single column and suppressor-based IC systems. Both types of ion chromatography systems provide detection limits in the low-ng/ml range with excellent linearity.  相似文献   

5.
A 10 cm silica monolith has been modified with iminodiacetic acid (IDA) groups and characterised for its selectivity toward alkali, alkaline earth, and selected transition metal cations. Physical characterisation of the modified monolith found non-homogeneous modification along the length of the monolith, although sufficient capacity was achieved to facilitate significant retention of alkaline earth and transition/heavy metal ions over a range of eluent pH and ionic strength conditions. For alkaline earth and transition/heavy metal ions, selectivity of the 10 cm IDA monolith closely matched that seen with a 25 cm IDA modified silica gel particle packed column, although the separation of alkali metal ions was noticeably poorer on the monolithic column. Peak efficiencies for most metal ions were of a similar order for both column types, except for Zn(II), which showed significant peak broadening on the IDA monolithic column.  相似文献   

6.
The application of laboratory-made aluminium-adsorbing silica gel (Al-Silica) as a cation-exchange stationary phase to ion chromatography-indirect photometric detection (IC-IPD) for common mono- and divalent cations (Li+, Na+, NH+, K+, Mg2+ and Ca2+) was carried out by using protonated tyramine (4-aminoethylphenol) as eluent ion. When using 1.2 mM tyramine-0.2 mM oxalic acid at pH 4.5 as eluent, incomplete separation of the monovalent cations and complete separation of the divalent cations were achieved in 17 min. Then, the addition of crown ethers in the eluent was carried out for the complete separation of the mono- and divalent cations. As a result, when using 1.2 mM tyramine--0.2 mM oxalic acid at pH 4.5 containing either 5 mM 15-crown-5 (1,4,7,10,13-pentaoxacyclopentadecane) or 0.5 mM and 18-crown-6 (1,4,7,10,13,16-hexaoxacyclooctadecane) as eluent, excellently simultaneous separation of these cations was achieved in 21 min. The proposed IC-IPD was successfully applied to the determination of major cations in natural water samples.  相似文献   

7.
The application of unmodified silica gel (Super Micro Bead Silica Gel B-5, SMBSG B-5) as a cation-exchange stationary phase in ion chromatography with indirect photometric detection (IC-IPD) for the separation of common mono- and divalent cations (Li+, Na+, NH4+, K+, Mg2+ and Ca2+) was carried out using various aromatic monoamines [tyramine [4-(2-aminoethyl)phenol], benzylamine, phenylethylamine, 2-methylpyridine and 2,6-dimethylpyridine] as eluents. When using these amines as eluents, the peak resolution between these mono- and divalent cations was not quite satisfactory and the peak shapes of NH4+ and K+ were largely destroyed on the SMBSG B-5 silica gel column. Hence, the application of SMBSG B-5 silica gel calcinated at 200, 400, 600, 800 and 1000 degrees C for 5 h in the IC-IPD was carried out. The peak shapes of the monovalent cations were greatly improved with increasing calcination temperature and, as a result, symmetrical peaks of these mono- and divalent cations were obtained on the SMBSG B-5 silica gel calcinated at 1000 degrees C as the stationary phase. In contrast, the peak resolution between these mono- and divalent cations was not improved. Therefore, crown ethers [18-crown-6 (1,4,7,10,13,15-hexaoxacyclooctadecane), 15-crown-5 (1,4,7,10,13-pentaoxacyclopentadecane)] were added to the eluent for the complete separation of these mono- and divalent cations. Excellent simultaneous separation and highly sensitive detection at 275 nm were achieved in 25 min on a column (150x4.6 mm I.D.) packed with SMBSG B-5 silica gel calcinated at 1000 degrees C by elution with 0.75 mM tyramine-0.25 mM oxalic acid at pH 5.0 containing either 1.0 mM 18-crown-6 or 10 mM 15-crown-5.  相似文献   

8.
The application of laboratory-made zirconium-modified silica gels (Zr-silicas) as cation-exchange stationary phases to ion chromatography with conductimetric detection (IC–CD) for common mono- and divalent cations (Li+, Na+, NH4+, K+, Mg2+ and Ca2+) was carried out. Zr-silicas were prepared by the reaction of the silanol group on the surface of silica gel with zirconium tetrabutoxide (Zr(OCH2CH2CH2CH3)4) in ethanol. Zr-silica adsorbed on 10 mg zirconium g−1 silica gel was a suitable cation-exchange stationary phase in IC–CD for the separation of these mono- and divalent cations. Excellent simultaneous separation and highly sensitive detection for these cations were achieved in 10 min by IC–CD using a Zr-silica column (150×4.6 mm I.D.) and 10 mM tartaric acid containing 10 mM 15-crown-5 (1,4,7,10,13-pentaoxacyclopentadecane) as the eluent. The proposed IC–CD method was successfully applied to the determination of major mono- and divalent cations in natural water samples.  相似文献   

9.
A single-column ion chromatography (SCIC) for the simultaneous determination of alkali, alkaline earth and transition metal elements in UO2, ThO2 powders and sintered (Th, U) O2 pellet is described in this paper. Metrosep cation 1-2 analytical column containing poly butadiene-maleic acid (PBDMA) coated silica has been applied to the ion chromatographic separation of 12 cations (copper, lithium, sodium, ammonium, nickel, potassium, zinc, cobalt, manganese, magnesium, calcium and strontium) using an isocratic elution with tartaric acid and oxalic acid as mobile phase with non-suppressed conductivity detection. Mobile phase composition was optimized to 1 mM tartaric acid and 0.75 mM oxalic acid for the baseline separation of 12 cations. The calibration plots were linear in the range of 0.05–40 mg L−1 with regression coefficients better than 0.998. The relative standard deviations (RSDs) of the retention time, peak area and peak height were less than 1, 2.8 and 3.0%, respectively. The recoveries of the spiked samples for the cations were 94–110%. The method developed was validated by comparison with certified standards of UO2 and ThO2 powders.  相似文献   

10.
The possibility of applying sulfonated cation exchangers on the basis of hypercrosslinked polystyrene (HCPS) of different ion-exchange capacity for the ion-chromatographic separation of alkali metal and ammonium cations was demonstrated. The effect of the nature and concentration of the eluent, the temperature of the chromatographic column, additions of an organic solvent to the eluent, and the ion-exchange capacity of the sorbent on the retention of cations was examined. An unusual selectivity of the sorbent for lithium and ammonium cations was found; the elution order can change for the Li+/Na+ and Rb+/NH+ 4 pairs depending on the nature of the eluent, the temperature, additions of an organic solvent, and the structural characteristics of the sorbent. When dilute solutions of nitric acid are used as the eluent, the following elution order of cations was obtained: Na+ < Li+ < K+ < NH+ 4 < Rb+ < Cs+ Mg2+ < Sr2+ < Ca2+ < Ba2+. Under the optimum conditions of separation (1 mM solution of sulfuric acid, 20°C) on sulfonated HCPS with an ion-exchange capacity of 0.07 mequiv/g, the separation of ammonium and alkali metal cations was achieved within 17 min.  相似文献   

11.
Arai K  Mori M  Hironaga T  Itabashi H  Tanaka K 《色谱》2012,30(4):404-408
A combination of hydrophilic interaction chromatographic(HILIC) column and a weakly acidic cation-exchange resin(WCX) column was used for simultaneous separation of inorganic anions and cations by ion chromatography(IC).Firstly,the capability of HILIC column for the separation of analyte ions was evaluated under acidic eluent conditions.The columns used were SeQuant ZIC-HILIC(ZIC-HILIC) with a sulfobetaine-zwitterion stationary phase(ZIC-HILIC) and Acclaim HILIC-10 with a diol stationary phase(HILIC-10).When using tartaric acid as the eluent,the HILIC columns indicated strong retentions for anions,based on ion-pair interaction.Especially,HILIC-10 could strongly retain anions compared with ZIC-HILIC.The selectivity for analyte anions of HILIC-10 with 5 mmol/L tartaric acid eluent was in the order of I-> NO-3 > Br-> Cl-> H2PO-4.However,since HILIC-10 could not separate analyte cations,a WCX column(TSKgel Super IC-A/C) was connected after the HILIC column in series.The combination column system of HILIC and WCX columns could successfully separate ten ions(Na+,NH+4,K+,Mg2+,Ca2+,H2PO-4,Cl-,Br-,NO-3 and I-) with elution of 4 mmol/L tartaric acid plus 8 mmol/L 18-crown-6.The relative standard deviations(RSDs) of analyte ions by the system were in the ranges of 0.02%-0.05% in retention times and 0.18%-5.3% in peak areas through three-time successive injections.The limits of detection at signal-to-noise ratio of 3 were 0.24-0.30 μmol/L for the cations and 0.31-1.2 μmol/L for the anions.This system was applied for the simultaneous determination of the cations and the anions in a vegetable juice sample with satisfactory results.  相似文献   

12.
Rong L  Liu Z  Ma M  Liu J  Xu Z  Lim LW  Takeuchi T 《Analytical sciences》2012,28(4):367-371
A non-suppressed capillary ion chromatographic method with a laboratory-made packed cation-exchange column (100 mm × 0.32 mm i.d.) was developed for the separation and simultaneous determination of five common inorganic cations (sodium, ammonium, potassium, magnesium and calcium). Cation exchangers were prepared by the reaction of the hydroxyl group on the surface of diol-group bonded silica gel with 1,3-propanesultone in methanol. Simultaneous separation of these five common inorganic cations were achieved within 17 min using 1 mM methanesulfonic acid and 0.1 mM 15-crown-5 ether in methanol-water (8:2, v/v) as the eluent. The effects of organic solvents and crown ethers in the eluent on the retention of analytes were investigated. The limits of detection (S/N = 3) of the cations were in the range of 18-124 μg/l, the linear correlation coefficients were 0.9991-0.9998, and the RSD values of retention time and peak height were all smaller than 2.1%. The present analytical method was successfully applied to the rapid and direct determination of inorganic cations in samples of river water and commercial drinks, with satisfactory results.  相似文献   

13.
A single-column chelation ion chromatographic system for the preconcentration and separation of trace transition metals is described. The system includes standard chromatographic equipment with a post-column reagent system based on the reaction with 4-(2-pyridylazo)resorcinol followed by photometric detection at 495 nm. Iminodiacetic acid bonded to 5 μm silica (Diasorb IDA) was used as a chelating stationary phase. The strong complexing ability in combination with good kinetics of complexation and ion-exchange selectivity of iminodiacetic functional groups allow both preconcentration of Mn, Co, Cd, Zn, Ni and Cu from waters of high salinity and efficient separation with the same column. The retention characteristics of alkaline-earth and transition metal ions on Diasorb IDA silica (250×4 mm I.D.) column was investigated for a variety of eluents including nitric acid, maleic, malonic, citric, dipicolinic, picolinic, tartaric and oxalic acids. The influence of ionic strength on retention of metal ions involving high nitrate and chloride concentrations was also evaluated. The baseline separation of preconcentrated metals was achieved using a three-step gradient elution scheme which involved first, flushing of the column loaded with the sample with 0.5 M KCl−0.5mMHNO3 for 10 min, followed by 80 mM tartaric acid for 20 min and finally 10 mM picolinic acid for 20 min.  相似文献   

14.
Yang R  Jiang S  Chen L 《Talanta》2001,55(6):355-1096
The use of poly(maleic acid–styrene)-encapsulated silica for the determination of monovalent and divalent cations is well accepted in ion chromatography. The separation of Mn2+, alkali and alkaline earth metal cations is obtained under the same chromatographic conditions. The influences of pH and the concentration of eluent on the retention of cations have been studied. The preparation conditions of packings were studied. The metal ions in the boiler water samples from a thermal power plant were quantitatively determined using this column. The results are in agreement with those determined by ICP and Volumetric analysis methods.  相似文献   

15.
聚马来酸包夹硅胶基质单柱弱阳离子色谱柱填料   总被引:6,自引:2,他引:6  
杨瑞琴  蒋生祥 《分析化学》1998,26(2):151-153
用马来酸包夹硅胶基质制备出一种新型弱阳离子色谱柱填料,该填料具有良好的色谱性能,可以较好地分离碱金属离子、碱土金属离子及一价胺离子。另外该填料可同时分离一价、二价金属阳离子。本文还考察了流动相的pH值和浓度对溶质保留的影响。  相似文献   

16.
The application of zirconium-modified silica gels (Zr–Silicas) as stationary phases for ion-exclusion chromatography with UV-photometric detection (IEC–PD) for mono-, di-, tri- and tetrabenzenecarboxylic acids (pyromellitic, trimellitic, hemimellitic, o-phthalic, salicylic and benzoic acids) and phenol was carried out using tartaric acid as the eluent. Zr–Silicas were prepared by the reaction of the silanol group on the surface of silica gel with zirconium tetrabutoxide [Zr(OCH2CH2CH2CH3)4] in ethanol solution. The effect of the amount of zirconium adsorbed on silica gel on chromatographic behavior of these benzenecarboxylic acids and phenol was investigated. As a result, Zr–Silica adsorbed on 20 mg zirconium g−1 silica gel was the most suitable stationary phase in the IEC–PD for the simultaneous separation of these benzenecarboxylic acids and phenol. Excellent simultaneous separation and highly sensitive UV detection at 254 nm for these benzenecarboxylic acids and phenol were achieved in 20 min by the IEC–PD using the Zr–Silica column (250×4.6 mm I.D.) and a 10 mM tartaric acid at pH 2.5 as eluent.  相似文献   

17.
Influence of acidic eluent on retention behaviors of common anions and cations by ion-exclusion/cation-exchange chromatography (ion-exclusion/CEC) were investigated on a weakly acidic cation-exchange resin in the H(+)-form with conductivity. Sensitivities of analyte ions, especially weak acid anions (F(-) and HCOO(-)), were affected with degree of background conductivity level with pK(a1) (first dissociation constant) of acid in eluent. The retention behaviors of anions and cations were related to that of elution dip induced after eluting acid to separation column and injecting analyte sample. These results were largely dependent on the natures of acid as eluent. Through this study, succinic acid as the eluent was suitable for simultaneous separation of strong acid anions (SO(4)(2-), Cl(-), NO(3)(-) and I(-)), weak acid anions (F(-), HCOO(-) and CH(3)COO(-)), and cations (Na(+), K(+), NH(4)(+), Mg(2+) and Ca(2+)). The separation was achieved in 20 min under the optimum eluent condition, 20 mM succinic acid/2 mM 18-crown-6. Detection limits at S/N=3 ranged from 0.10 to 0.51 microM for strong acid anions, 0.20 to 5.04 microM for weak acid anions and 0.75 to 1.72 microM for cations. The relative standard deviations of peak areas in the repeated chromatographic runs (n=10) were in the range of 1.1-2.9% for anions and 1.8-4.5% for cations. This method was successfully applied to hot spring water containing strong acid anions, weak acid anions and cations, with satisfactory results.  相似文献   

18.
An ion chromatography method is described for the simultaneous determination of anions (Cl, NO3, and SO42–) and cations (Na+, NH4+, K+, Mg2+, and Ca2+) using a single pump, a single eluent and a single detector. An anion-exchange column modified with chondroitin sulfate C facilitated the elution of the above three anions using 5 mM tartaric acid as the eluent in isocratic mode, whereas the same eluent facilitated the separation of the above five cations on a commercially-available cation-exchange column. The separation columns were connected in series via two six-port switching valves, so the required cation-exchange or anion-exchange separation could be carried out by selecting the appropriate positions for the switching valves. The separations were completed in 30 min.  相似文献   

19.
单一阴离子交换柱同时分离有机酸和无机阴阳离子   总被引:8,自引:0,他引:8  
丁明玉  陈培榕 《分析化学》1997,25(2):161-164
研究了用乙二胺四乙酸(EDTA)作淋洗液时,性质迥异的有机酸、无机阴离子和碱土金属离子(Ca^2+、Mg^2+)在同一阴离子交换柱上的同时分离以及保留机理,结果表明,在离子交换机理之外,非离子交换机理对有机酸及钙镁的EDTA络阴郭的保留行为起一定的辅助作用,9种有机酸和无机阴阳离子在10min内得到了较好的分离。各离子的电导检测灵敏度在10^-9至10^-11mol,能满足环境和食吕分析的要求。  相似文献   

20.
Summary The simultaneous ion-chromatography of mono-and divalent metal ions on the weak cation-exchange column Nucleosil-PBDMA (polymer coated silica with polybutandiene-maleic acid) with conductivity and indirect UV-detection is presented. The influences of eluents containing organic complexing acids (-hydroxy-isobutyric, tartaric, citric, oxalic, pyridine-2,6-dicarbonic acid and EDTA etc.) as well as UV-absorbing, displacing counterions [Cu(II), Ce(III) etc.] on the retention times of metal ions was investigated in detail. With the combination of citric acid-PDCA as eluent all alkali and alkaline earth ions could be completely separated within 12 min. Alkali, alkaline earth and heavy metal ions [Cu/Zn/Co/Fe(II)] were separated by the combination of tartaric and oxalic acid as eluent in a single run. Trace amounts of Na, K and Ca were successfully separated from the Mg-matrix by an EDTA-PDCA eluent. For the IC with indirect UV-detection the eluent consisting of CuSO4 or CuCl2 was used to separate Na, K, Mg and Ca with baseline resolution within 10 min.The detection limits of metal ions with conductivity detection were found beween 0.5 g/l for Li and 8 g/l for Cs. They were 10 times more sensitive than those with indirect UV-detection.This IC-method was applied to determine alkali, alkaline earth and Mn ions in the water, food, ore-cinder and sole-brine samples with satisfactory results.Dedicated to Prof. Dr. G. Schulze on the occasion of his 60th birthday  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号