首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
Summary A commercially available graphite furnace was modified in order to use it as an electrothermal vaporization device for solid sample analysis with an inductively coupled plasma atomic emission spectrometer. An evaluation of two different ETV systems has been made. This paper mainly describes the different aspects which must be taken into account when coupling an ETV system to an ICP. Cu was chosen as an element easy to determine and Cd and Pb as elements with more difficulties. From the optimization it was found that the transport efficiency for Cd in solution and solid is different, whereas for Cu and Pb the efficiencies are in good agreement for both sample types. Calibration with solids and liquids was attempted for Cu. The paper gives preliminary results on the determination of Cu in solid reference materials. In some cases (e.g. Pb) a background correction based on a linear interpolation seemed not satisfactory. Detection limits and limits of determination for Cu, Cd and Pb in different solid samples are given.Presented at the 5th International Colloquium on Solid Sampling with Atomic Spectroscopy, May 18–20, 1992; Geel, Belgium. Papers edited by R. F. M. Herber, Amsterdam  相似文献   

2.
A method has been described for the direct determination of Ti, Cu, Mn, Cr and Cd in solid biological samples without any chemical pretreatment by fluorination assisted electrothermal vaporization inductively coupled plasma atomic emission spectrometry (ETV-ICP-AES) with slurry sampling. A polytetrafluorethylene (PTFE) emulsion was used as a fluorinating reagent to promote the vaporization of the analytes from the graphite furnace. The interface between furnace device and ICP torch and the main factors affecting the analytical signal were investigated systematically. The detection limits for the determination of Ti, Cu, Mn, Cr and Cd are 6.3, 4.7, 10, 13 and 278 ng/mL, respectively; the relative standard deviations are in the range of 1.5 (Mn) ∼4.0% (Cd) after optimization of the operating conditions. The recommended approach has been applied to directly determine the trace elements of interest in the Chinese traditional medicine Loulu and in the solid biological standard reference material (peach leaves, GBW 08501) with satisfactory results. Received: 28 December 1998 / Revised: 9 February 1999 / Accepted: 12 February 1999  相似文献   

3.
A method has been described for the direct determination of Ti, Cu, Mn, Cr and Cd in solid biological samples without any chemical pretreatment by fluorination assisted electrothermal vaporization inductively coupled plasma atomic emission spectrometry (ETV-ICP-AES) with slurry sampling. A polytetrafluorethylene (PTFE) emulsion was used as a fluorinating reagent to promote the vaporization of the analytes from the graphite furnace. The interface between furnace device and ICP torch and the main factors affecting the analytical signal were investigated systematically. The detection limits for the determination of Ti, Cu, Mn, Cr and Cd are 6.3, 4.7, 10, 13 and 278 ng/mL, respectively; the relative standard deviations are in the range of 1.5 (Mn) ∼4.0% (Cd) after optimization of the operating conditions. The recommended approach has been applied to directly determine the trace elements of interest in the Chinese traditional medicine Loulu and in the solid biological standard reference material (peach leaves, GBW 08501) with satisfactory results. Received: 28 December 1998 / Revised: 9 February 1999 / Accepted: 12 February 1999  相似文献   

4.
A new approach to sample digestion, subsequent vaporization and introduction into an inductively coupled plasma atomic emission spectrometer was developed for the direct determination of lead. To each small sample cuvette made of tungsten, a mixture of a ground solid sample and powdered diammonium hydrogenphosphate was precisely weighed. The cuvette was positioned onto the tungsten boat furnace (TBF) incorporating a vaporizer. Tetramethylammonium hydroxide solution was added. Then the cuvette was heated and maintained at a wet-digestion temperature to decompose the solid sample. After digestion, the temperature was elevated to generate the analyte vapor for introduction into a plasma. Since the solid samples were wet-digested in the sample cuvettes before vaporization, they could be analyzed by using a calibration curve prepared from aqueous standard solutions. This method was applied to the determination of lead in several biological materials with satisfactory results.  相似文献   

5.
A new approach to sample digestion, subsequent vaporization and introduction into an inductively coupled plasma atomic emission spectrometer was developed for the direct determination of lead. To each small sample cuvette made of tungsten, a mixture of a ground solid sample and powdered diammonium hydrogenphosphate was precisely weighed. The cuvette was positioned onto the tungsten boat furnace (TBF) incorporating a vaporizer. Tetramethylammonium hydroxide solution was added. Then the cuvette was heated and maintained at a wet-digestion temperature to decompose the solid sample. After digestion, the temperature was elevated to generate the analyte vapor for introduction into a plasma. Since the solid samples were wet-digested in the sample cuvettes before vaporization, they could be analyzed by using a calibration curve prepared from aqueous standard solutions. This method was applied to the determination of lead in several biological materials with satisfactory results.  相似文献   

6.
7.
Slurry sampling followed by electrothermal vaporization was used as sample introduction technique for digestion-free analysis of aluminium nitride and aluminium oxide by inductively coupled plasma atomic emission spectrometry. The vaporizer consisted of a tungsten coil in a quartz chamber. Spectral interferences and background emission caused by tungsten ablation from the coil were reduced by coating it with tungsten carbide. Different approaches for background correction techniques were considered. The analytes Ca, Cd, Co, Cr, Cu, Fe, Mg, Ni and Zn were determined simultaneously, whereas Mn and Na were determined in the sequential mode. Calibration was performed using the standard additions method. The accuracy was checked by comparison of the results with those of independent methods. Detection limits between 0.01 (Mg) and 8.5 μg/g (Co) were achieved.  相似文献   

8.
An electrothermal vaporization (ETV) system useful for the analysis of solutions and slurries has been coupled with a sector-field inductively coupled plasma mass spectrometer (ICP–MS) equipped with an array detector. The ability of this instrument to record the transient signals produced for a number of analytes in ETV–ICP–MS is demonstrated. Detection limits for Mn, Fe, Co, Ni, Cu, Zn and Ga are in the range of 4–60 pg μL 1 for aqueous solutions and in the low μg g 1 range for the analysis of 10 mg mL 1 slurries of Al2O3 powders. The dynamic ranges measured for Fe, Cu and Ga spanned 3–5 orders of magnitude when the detector was operated in the low-gain mode and appear to be limited by the ETV system. Trace amounts of Fe, Cu and Ga could be directly determined in Al2O3 powders at the 2–270 μg g 1 level without the use of thermochemical reagents. The results well agree with literature values for Fe and Cu, whereas deviations of 50% at the 90 μg g 1 level for Ga were found.  相似文献   

9.
Slurry sampling followed by electrothermal vaporization was used as sample introduction technique for digestion-free analysis of aluminium nitride and aluminium oxide by inductively coupled plasma atomic emission spectrometry. The vaporizer consisted of a tungsten coil in a quartz chamber. Spectral interferences and background emission caused by tungsten ablation from the coil were reduced by coating it with tungsten carbide. Different approaches for background correction techniques were considered. The analytes Ca, Cd, Co, Cr, Cu, Fe, Mg, Ni and Zn were determined simultaneously, whereas Mn and Na were determined in the sequential mode. Calibration was performed using the standard additions method. The accuracy was checked by comparison of the results with those of independent methods. Detection limits between 0.01 (Mg) and 8.5 μg/g (Co) were achieved. Received: 21 September 1998 / Revised: 30 October 1998 / Accepted: 3 November 1998  相似文献   

10.
A direct inductively coupled plasma atomic emission method for the determination of Ag, Al, As, Ca, Cd, Co, Cu, Fe, Ga, K, Li, Mg, Na and Pb in high-purity tantalum powders has been developed. The electrothermal vaporization technique using a modified longitudinally-heated Grün-ETAAS furnace with sample introduction on a platform and an automated sampling workstation provided the possibility of in situ analyte-matrix separation, freedom of blank, and applicability to routine analysis. Hard- and software were modified to allow signal recording and data processing independent of the spectrometer software. The extent of spectral interferences by Ta-emission at the analyte wavelengths used was determined and the analyte signals of each sample run were automatically corrected. Limits of detection ranging from 5 ng/g (Ag, Cu) to 250 ng/g (K, Pb) were obtained using optimized furnace and spectrometer conditions. The method was applied to the analysis of two tantalum samples and the results for Cu, Fe, K, Mg and Na were compared with those obtained by liquid and solid-samping ETAAS, showing satisfactory agreement.  相似文献   

11.
A novel method for the determination of trace elements in microliter samples using the tantalum filament electrothermal vaporization/low-pressure inductively coupled plasma (ETV/LP-ICP) atomic emission spectrometry has been developed. An improved tantalum filament ETV was directly coupled with LP-ICP system for efficient vaporization of microliter samples and further quantitative analysis. The experimental parameters including ETV current, rf power and mass flow rate of argon carrier gas were optimized using the copper emission signal produced by 5 μl of standard solution (5 μg/ml). Under the optimized condition, the analytical performances including linearity, precision and detection limit for the developed system were investigated. Absolute detection limits in the range of 22–391 pg for selected eight elements (Fe, Cu, Cr, Mn, Pb, K, Zn and Mg) were obtained with satisfactory precision (<8.9% RSD). The feasibility of the developed system has been demonstrated by analyzing wheat gluten NIST standard sample.  相似文献   

12.
A procedure based on electrothermal evaporation (ETV) and inductively coupled plasma atomic emission spectrometry (ICP-OES) for the determination of trace impurities in Al2O3 powders without any sample pretreatment is presented. With the aid of matrix modifier the transport and the evaporation efficiency for refractory compounds could be increased by forming halides with a lower boiling point. As calibration is still a problem in direct solid sample analysis, different calibration approaches including the use of certified reference materials from NIST and standard addition of aqueous solutions of analytes were discussed. The accuracy obtained with calibration and with the standard addition method was shown up for the elements Ca, Fe, Ga, Mg, Mn, Na, Ni and V for the case of Al2O3 NIST standard reference material (SRM 699). The ETV–ICP-OES method was used for the analysis of Al2O3 powders with impurities in the low μg/g range and the results for the elements Ca, Fe, Ga, Mg, Mn, Na, Ni and V obtained with evaporation of discrete powder amounts with ETV–ICP-OES and slurry evaporation under the use of ultrasonic homogenization during the sampling and ETV–ICP-MS were shown to be in a good agreement.  相似文献   

13.
Possibilities of electrothermal sample vaporization in inductively coupled plasma atomic emission spectrometry (ETV-ICP-AES) in the analysis of high-purity reagents were studied on an example high-purity waters, acid solutions, and trace impurity concentrates. The analytical and background signals in the injection of solutions into inductively coupled plasma (ICP) by pneumatic nebulization and electrothermal vaporization were compared and the of limits of detection in the analysis of high-purity reagents with impurity preconcentration by evaporation were estimated and compared.  相似文献   

14.
Ultrasonic slurry sampling electrothermal vaporization inductively coupled plasma mass spectrometry (USS-ETV-ICP-MS) is a very powerful technique for the direct analysis of solid materials prepared as slurries. The use of isotope dilution USS-ETV-ICP-MS (USS-ETV-ID-ICP-MS) for micro-homogeneity characterization studies of powdered reference materials based on elemental analyses, was investigated. Slurry analysis conditions were optimized taking into consideration density, particle size, analyte extraction, slurry mixing, analyte transport and sampling depth. Slurries were prepared using 1–20 mg of material and adding 1.0 ml of 5% nitric acid diluent containing 0.005% Triton X-100®. Three reference materials were analyzed (RM 8431a Mixed Diet, SRM 1548a Typical Diet and SRM 2709 San Joaquin Soil). Cu and Ni were determined in each material and Fe was also determined in RM 8431a Mixed Diet. ETV conditions were optimized and the benefit of using Pd as a carrier to enhance transport, combined with oxygen ashing was demonstrated. The accuracy of the method was verified by comparing analytical results with certified values. The precision of the method was demonstrated by comparing R.S.D.'s for slurry samples and aqueous standards and elemental ‘homogeneity’ was quantified based on the slurry sampling variability. The representative sample mass analyzed was calculated taking into consideration extraction of analyte into the liquid phase of the slurry. Representative sample masses of approximately 4 mg of RM 8431a provided slurry sampling variabilities of 10% or less for Cu, Fe and Ni. Representative sample masses of approximately 10 mg of SRM 1548a provided slurry sampling variabilities of approximately 10% for Cu and Ni. Representative sample masses of approximately 0.3 mg of SRM 2709 resulted in total analytical variabilities of less than 7%, highlighting the fact that the San Joaquin Soil is clearly the most homogeneous of the materials characterized.  相似文献   

15.
A method has been developed for the determination of trace impurities in silicon nitride (Si3N4) powders by fluorination assisted electrothermal vaporization (ETV) /ICP-AES using the slurry sampling technique. Polytetrafluoroethylene (PTFE) emulsion as a fluorinating reagent not only effectively destroys the skeleton of Si3N4, but also carries out selective volatilization between the impurity elements (Cu, Cr) and the matrix (Si). The experimental parameters influencing fluorination reactions were optimized. The detection limits for Cu and Cr are 1.05 ng/mL ( Cu) and 1.58 ng/mL (Cr), the RSDs are in the range of 1.9–4.2%. The proposed method has been applied to the determination of Cu and Cr in Si3N4 ceramic powders. The analytical results were compared with those obtained by independent methods.  相似文献   

16.
A method has been developed for the determination of trace impurities in silicon nitride (Si3N4) powders by fluorination assisted electrothermal vaporization (ETV) /ICP-AES using the slurry sampling technique. Polytetrafluoroethylene (PTFE) emulsion as a fluorinating reagent not only effectively destroys the skeleton of Si3N4, but also carries out selective volatilization between the impurity elements (Cu, Cr) and the matrix (Si). The experimental parameters influencing fluorination reactions were optimized. The detection limits for Cu and Cr are 1.05 ng/mL ( Cu) and 1.58 ng/mL (Cr), the RSDs are in the range of 1.9–4.2%. The proposed method has been applied to the determination of Cu and Cr in Si3N4 ceramic powders. The analytical results were compared with those obtained by independent methods. Received: 8 December 1998 / Revised: 1 February 1999 / Accepted: 3 February 1999  相似文献   

17.
Electrothermal vaporization (ETV) inductively coupled plasma optical emission spectrometry (ICP-OES) and inductively coupled plasma mass spectrometry (ICP-MS) with polyvinylidene fluoride (PVDF) as chemical modifier are critically compared for the determination of refractory elements in coal fly ash and airborne particulates. The atmospheric particulates that collected on a PVDF filter were introduced into the graphite furnace in the form of a slurry by dissolving the filter in dimethylformamide, and the dissolved filter PVDF, along with additional added PVDF powder, was used as a chemical modifier for subsequent ETV-ICP-OES and ETV-ICP-MS determination. The vaporization behaviors of analytes (Ti, Zr, V, Mo, Cr, La) in ETV-ICP-OES/MS were studied in detail, and the optimal ETV operating parameters were obtained. Under the optimized operating conditions, the detection limits of target elements were 0.08-2.7 ng m(-3) for ETV-ICP-OES and 0.5-50 pg m(-3) for ETV-ICP-MS, respectively, with analytical precisions of 3.5-7.3% for ETV-ICP-OES and 3.9-9.6% for ETV-ICP-MS, respectively. The tolerable amounts of matrix elements for ETV-ICP-OES are higher than for ETV-ICP-MS. Both ETV-ICP-OES and ETV-ICP-MS were used to directly determine the trace refractory elements in coal fly ash and airborne particulates and the analytical results are comparable.  相似文献   

18.
A method for the direct determination of trace rare earth elements in ancient porcelain samples by slurry sampling fluorinating electrothermal vaporization inductively coupled plasma mass spectrometry was developed with the use of polytetrafluoroethylene as fluorinating reagent. It was found that Si, as a main matrix element in ancient porcelain sample, could be mostly removed at the ashing temperature of 1200 °C without considerable losses of the analytes. However, the chemical composition of ancient porcelain sample is very complicated, which makes the influences resulting from other matrix elements not be ignored. Therefore, the matrix effect of ancient porcelain sample was also investigated, and it was found that the matrix effect is obvious when the matrix concentration was larger than 0.8 g l 1. The study results of particle size effect indicated that when the sample particle size was less than 0.057 mm, the particle size effect is negligible. Under the optimized operation conditions, the detection limits for rare earth elements by fluorinating electrothermal vaporization inductively coupled plasma mass spectrometry were 0.7 ng g 1 (Eu)–33.3 ng g 1(Nd) with the precisions of 4.1% (Yb)–10% (La) (c = 1 μg l 1, n = 9). The proposed method was used to directly determine the trace rare earth elements in ancient porcelain samples produced in different dynasty (Sui, Ming and Qing), and the analytical results are satisfactory.  相似文献   

19.
Electrothermal vaporization (ETV) sample introduction in inductively coupled plasma atomic emission spectrometry suffers from severe matrix effects. In the present study, the differences between wet and dry plasma conditions are studied. In addition, the influence of the sample composition was investigated. An inductively coupled plasma optical emission spectrometer, with detection based on charge transfer, allowed the simultaneous measurement of ionic and atomic emission line intensities during the transient signal. Mg and Cr were the test elements. The ion-to-atom line ratio increases at higher power settings, but the changes were larger when a nebulizer was used for sample introduction than with ETV sample introduction. The decrease of ion-to-atom line ratios at increasing observation height was more pronounced when ETV was used, due to the absence of water vapor. The gas flow rate showed a stronger influence for nebulization than for ETV. In the presence of a calcium matrix, lower ion-to-atom line ratios were observed, but the ratio did not change significantly within the transient emission signal. Similar line ratios were observed for different amounts of calcium matrix. The values of ion-to-atom line ratios for Mg and Cr indicate that the plasma ionization and thermal characteristics are not modified due to the presence of the calcium matrix.  相似文献   

20.
An annular helium inductively coupled plasma (He ICP) was generated at atmospheric pressure. No external cooling was used to stabilize the plasma. Aqueous solution was injected into the plasma without any difficulty. Preliminary results revealed that the annular He ICP was capable of exciting elements such as Cl and Br which possess high excitation energies. Atomic emission detection limits for Cl and Br were improved by factors of 63 and 34, respectively, as compared to the results obtained from the argon inductively coupled plasma. The excitation temperature of the annular He ICP (4180 K) was less than that of an Ar ICP (5570 K).  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号