首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
磁共振成像(Magntic Resonance Imaging,MRI)技术是一种先进的医疗影像技术.在MRI系统中,通过梯度线圈电流快速切换方向,对待测区域施加梯度磁场,产生的梯度磁场会在其周围的金属体内激发出变化的涡旋电场,进而导致金属体内闭合的回路中产生对原来的梯度电流起抑制作用的感生电流,也就是我们所说的涡流.本文介绍了一种测量磁体涡流场的方法,结合电磁感应定律,设计了一种磁体涡流场测量装置,通过硬件采集以及软件处理的方法,将理想梯度场与实际磁场进行相减并将波形实时呈现,实验结果表明该方法可实现对磁体涡流场的测量.  相似文献   

2.
Compensation of gradient-induced magnetic field perturbations   总被引:3,自引:0,他引:3  
Pulsed magnetic field gradients are essential for MR imaging and localized spectroscopy applications. However, besides the desired linear field gradients, pulsed currents in a strong external magnetic field also generate unwanted effects like eddy currents, gradient coil vibrations and acoustic noise. While the temporal magnetic field perturbations associated with eddy currents lead to spectral line shape distortions and signal loss, the vibration-related modulations lead to anti-symmetrical sidebands of any large signal (i.e. water), thereby obliterating the signals from low-concentration metabolites. Here the measurement, characterization and compensation of vibration-related magnetic field perturbations is presented. Following a quantitative evaluation of the various temporal components of the main magnetic field, a digital B0 magnetic field waveform is generated which reduces all temporal variations of the main magnetic field to within the spectral noise level.  相似文献   

3.
Almost all NMR imaging and localized spectroscopic methods fundamentally rely on the use of magnetic field gradients. It follows that precise information on gradient waveform shape and rise-times is often most useful in experimental MRI. We present a very simple and robust method for measuring the time evolution of a magnetic field gradient. The method is based on the analysis of the NMR signal in the time domain, and requires no specialized field measurement probes for its implementation. The technique makes use of the principal that for small flip angles the excitation profile is a good approximation to the Fourier transform of the radio frequency pulse shape. Creation of the NMR signal can be considered as an inverse Fourier transform and thus variation of the gradient strength during the excitation pulse influences the shape of the NMR signal. Although originally designed for measurement of the rise time only, we have now extended the technique to measure the exact time course of the gradient. The theory is confirmed by experimental results for gradient waveform field measurements in a high-field vertical bore system.  相似文献   

4.
Tissues with very short transverse relaxation time (T2) cannot be detected using conventional magnetic resonance (MR) sequences due to the rapid decay of excited MR signals. In this work, a multiecho sequence employing half-pulse excitation and spiral sampling was developed for ultrashort echo time (UTE) imaging of tissues with short T2. Spiral readout gradients were measured and precompensated to reduce gradient distortions due to eddy currents and gradient anisotropy. The effects of spatial blurring due to fast signal decay were investigated experimentally through spiral UTE (SUTE) imaging of rubber bands with different spiral sampling duration. The unwanted long T2 signals were suppressed through the use of an inversion pulse and nulling, and/or subtraction of a later echo image from the initial one. This technique has been applied to imaging of the short T2 components in brain white matter, knee cartilage, bone and carotid vessel wall of normal volunteers at 1.5 T. Preliminary results show high spatial resolution and excellent image contrast for a variety of short T2 tissues in the human body under a relatively short scan time. A quantitative comparison was also made between radial UTE and SUTE in terms of signal-to-noise ratio efficiency.  相似文献   

5.
Interest in nuclear magnetic resonance measurements at ultra-low magnetic fields (ULF, approximately microT fields) has been motivated by various benefits and novel applications including narrow NMR peak-width, negligible susceptibility artifacts, imaging of samples inside metal containers, and possibility of directly imaging neuronal currents. ULF NMR/MRI is also compatible with simultaneous measurements of biomagnetic signals. However the most widely used technique in ULF NMR-prepolarization at high field and measurement at lower field-results in large transient signals which distort the free induction decay signal. This is especially severe for the measurement of signals from samples and materials with short T1 time. We have devised an approach that largely cancels the transient signals. The technique was successfully used to measure NMR signals from liquids and gases with T1 in the range 1-4 ms.  相似文献   

6.
Probes capable of generating short high intensity pulsed magnetic field gradients are commonly used in diffusion studies of systems with very short T(2). Traditional methods of calibrating magnetic field gradients present unique challenges at ultrahigh field strengths and are often inapplicable. Currently the most accurate method of determining magnetic gradient strength is to use the known diffusion coefficient of a standard sample and determine gradient strength from the echo attenuation plot of a diffusion experiment, however, there are problems with finding suitable standards for high intensity gradients. Here, we show that molecules containing at least two receptive nuclei (i.e. one with high and one with low gyromagnetic ratios) are excellent systems for calibrating high intensity gradients.  相似文献   

7.
Eddy currents are inevitably induced when time-varying magnetic field gradients interact with the metallic structures of a magnetic resonance imaging (MRI) scanner. The secondary magnetic field produced by this induced current degrades the spatial and temporal performance of the primary field generated by the gradient coils. Although this undesired effect can be minimized by using actively and/or passively shielded gradient coils and current pre-emphasis techniques, a residual eddy current still remains in the MRI scanner structure. Accurate simulation of these eddy currents is important in the successful design of gradient coils and magnet cryostat vessels. Efficient methods for simulating eddy currents are currently restricted to cylindrical-symmetry. The approach presented in this paper divides thick conducting cylinders into thin layers (thinner than the skin depth) and expresses the current density on each as a Fourier series. The coupling between each mode of the Fourier series with every other is modeled with an inductive network method. In this way, the eddy currents induced in realistic cryostat surfaces by coils of arbitrary geometry can be simulated. The new method was validated by simulating a canonical problem and comparing the results against a commercially available software package. An accurate skin depth of 2.76 mm was calculated in 6 min with the new method. The currents induced by an actively shielded x-gradient coil were simulated assuming a finite length cylindrical cryostat consisting of three different conducting materials. Details of the temporal-spatial induced current diffusion process were simulated through all cryostat layers, which could not be efficiently simulated with any other method. With this data, all quantities that depend on the current density, such as the secondary magnetic field, are simply evaluated.  相似文献   

8.
In permanent magnetic resonance imaging (MRI) systems, pulsed gradient fields induce strong eddy currents in the conducting structures of the magnet body. The gradient field for image encoding is perturbed by these eddy currents leading to MR image distortions. This paper presents a comprehensive finite element (FE) analysis of the eddy current generation in the magnet conductors. In the proposed FE model, the hysteretic characteristics of ferromagnetic materials are considered and a scalar Preisach hysteresis model is employed. The developed FE model was applied to study gradient z-coil induced eddy currents in a 0.5 T permanent MRI device. The simulation results demonstrate that the approach could be effectively used to investigate eddy current problems involving ferromagnetic materials. With the knowledge gained from this eddy current model, our next step is to design a passive magnet structure and active gradient coils to reduce the eddy current effects.  相似文献   

9.
高场强核磁共振下测量水的自旋晶格弛豫时间   总被引:1,自引:0,他引:1  
在反转恢复脉冲序列中增加双极性梯度场脉冲以压制辐射阻尼效应,从而使之能够在高场强核磁共振波谱仪(Bruker AV600)中较为准确测量水的自旋-晶格时间.这一方法应用于商品化成像对比剂Gd-DTPA的弛豫率测试,得到的结果和文献相似,证实了该方法的可靠性.进一步应用于新合成成像对比剂TEMDP-EMFs性能的评价.  相似文献   

10.
Gradient eddy currents, induced in the surrounding conductive structures in a magnetic resonance (MR) magnet, are a major problem in MR imaging, in localized MR spectroscopy and in many other MR experiments. We present a comparison of three methods of measuring the gradient time characteristics and the time changes of basic magnetic fieldB 0 after the gradient is switched off. The methods are based on the selective excitation of a thin layer of the sample and on acquiring the MR signal obtained after the end of the gradient pulse and on the computation of the instantaneous frequency of the signal. At this point, the time gradient characteristic is proportional to the instantaneous frequency of the MR signal, which has a small signal-to-noise ratio. We use the characteristics measured to set the pre-emphasis parameters in a 200 MHz/200 mm MR scanner. From the results obtained by measurement it follows that all methods are convenient for simple and quick characterization of magnetic field gradient in MR tomographic magnets.  相似文献   

11.
为获得更优的成像质量和更快的成像速度,磁共振成像(MRI)系统的梯度预加重模块需要具有更多的补偿通道和调节参数,常规预加重模块的设计方案使现场可编程门阵列(FPGA)面临巨大的资源消耗.为解决高性能梯度预加重模块的资源消耗大的问题,本文提出了一种基于分时复用技术的梯度预加重实现方案,以常规方案1/44的资源实现了11通道×4组参数的梯度预加重模块.将该模块用于0.35 T MRI系统,测试了补偿前后的涡流曲线和磁共振图像,结果表明该模块有效降低了系统的涡流,减小了磁共振图像中的涡流伪影.  相似文献   

12.
In ultra-low-field magnetic resonance imaging (ULF MRI), superconductive sensors are used to detect MRI signals typically in fields on the order of 10-100 μT. Despite the highly sensitive detectors, it is necessary to prepolarize the sample in a stronger magnetic field on the order of 10-100 mT, which has to be switched off rapidly in a few milliseconds before signal acquisition. In addition, external magnetic interference is commonly reduced by situating the ULF-MRI system inside a magnetically shielded room (MSR). With typical dipolar polarizing coil designs, the stray field induces strong eddy currents in the conductive layers of the MSR. These eddy currents cause significant secondary magnetic fields that may distort the spin dynamics of the sample, exceed the dynamic range of the sensors, and prevent simultaneous magnetoencephalography and MRI acquisitions. In this paper, we describe a method to design self-shielded polarizing coils for ULF MRI. The experimental results show that with a simple self-shielded polarizing coil, the magnetic fields caused by the eddy currents are largely reduced. With the presented shielding technique, ULF-MRI devices can utilize stronger and spatially broader polarizing fields than achievable with unshielded polarizing coils.  相似文献   

13.
The FID-Acquired-Echo sequence (FAcE) is a magnetic resonance imaging technique using fractional-echo acquisitions, with sequential separate sampling of the right and left k-space half planes. It reduces the minimal echo times by about a factor of two, compared to conventional full-(gradient)-echo sampling schemes. With this sequence, implemented on a commercial 1.5 Tesla whole body system, high resolution images are acquired with typical echo times between 3 and 4.5 msec. Using short echo times the signal dephasing caused by velocity and higher order spin motion is reduced. Further, due to the modified sampling scheme, the sequence exhibits, for triggered studies, partially a compensation of motion-induced phase shifts in the frequency-encoding direction. Thus, the sequence offers an alternative means for the reduction of motion-induced image artefacts to the use of flow compensating gradients, which usually makes a sequence more sensitive to higher order motion and introduces further eddy currents. Besides potential application for imaging of nuclei and tissues with short T2 relaxation times, and non-ECG-triggered in-flow angiography, the main application seems to be triggered-phase contrast imaging with focus on quantitation of blood flow. Its usefulness is largest in cases with irregular flow patterns, where considerable in-plane flow occurs.  相似文献   

14.
Due to the large eddy currents at the ends of the quadrupole magnets for CSNS/RCS, the magnetic field properties and the heat generation are of great concern. In this paper, we take transient electromagnetic simulation and make use of the eddy current loss from the transient electromagnetic results to perform thermal analysis. Through analysis of the simulated results, the magnetic field dynamic properties of these magnets and a temperature rise are achieved. Finally, the accuracy of the thermal analysis is confirmed by a test of the prototype quadrupole magnet of the RCS.  相似文献   

15.
We investigate the use of intermolecular multiple-quantum coherence to probe structural anisotropy in trabecular bone. Despite the low volume fraction of bone, the bone-water interface produces internal magnetic field gradients which modulate the dipolar field, depending on sample orientation, choice of dipolar correlation length, correlation gradient direction, and evolution time. For this system, the probing of internal magnetic field gradients in the liquid phase permits indirect measurements of the solid phase dipolar field. Our results suggest that measurements of volume-averaged signal intensity as a function of gradient strength and three orthogonal directions could be used to non-invasively measure the orientation of structures inside a sample or their degree of anisotropy. The system is modeled as having two phases, solid and liquid (bone and water), which differ in their magnetization density and magnetic susceptibility. A simple calculation using a priori knowledge of the material geometry and distribution of internal magnetic fields verifies the experimental measurements as a function of gradient strength, direction, and sample orientation.  相似文献   

16.
The need for convection compensating methods in NMR has been manifested through an increasing number of publications related to the subject over the past few years (J. Magn. Reson. 125, 372 (1997); 132, 13 (1998); 131, 126 (1998); 118, 50 (1996); 133, 379 (1998)). When performing measurements at elevated temperature, small convection currents may give rise to erroneous values of the diffusion coefficient. In work with high resolution NMR spectroscopy, the application of magnetic field gradients also introduces an eddy-current magnetic field which may result in errors in phase and baseline in the FFT-spectra. The eddy current field has been greatly suppressed by the application of bipolar magnetic field gradients. However, when introducing bipolar magnetic field gradients, the pulse sequence is lengthened significantly. This has recently been pointed out as a major drawback because of the loss of coherence and of NMR-signal due to transverse relaxation processes. Here we present modified convection compensating pulsed field gradient double spin echo and double stimulated echo sequences which suppress the eddy-current magnetic field without increasing the duration of the pulse sequences.  相似文献   

17.
针对交流二极磁铁的磁场特性和涡流问题,利用电磁场分析软件对磁铁进行了优化设计和温度场计算,确定了交流二极磁铁关键技术的方案。对交流二极磁铁极头端面采用了罗高斯基曲线和谐波削斜的方法来提高磁铁磁场质量;对铁芯端部和端板进行开槽优化设计,有效切断磁铁端部主要的涡流回路,降低了磁铁温升;磁铁线圈采用铝绞线导线进行绕制,以减少磁铁线圈内的涡流损耗。最后,通过对样机磁铁的测试,磁场均满足物理要求,磁铁温度也控制在安全范围内。  相似文献   

18.
Diffusion-weighted echo-planar magnetic resonance imaging is potentially of great importance as a diagnostic imaging tool; however, the technique currently suffers a number of limitations, including the image distortion caused by the eddy current induced fields when the diffusion-weighting magnetic field gradient pulses are applied. The distortions cause mis-registration between images with different diffusion-weighting, that then results in artifacts in quantitative diffusion images. A method is presented to measure the magnetic fields generated from the eddy currents for each of three orthogonal gradient pulse vectors, and then to use these to ascertain the image distortion that occurs in subsequent diffusion-weighted images with arbitrary gradient pulse vector amplitude and direction, and image plane orientation. The image distortion can then be reversed. Both temporal and spatial dependence of the residual eddy current induced fields are included in the analysis. Image distortion was substantially reduced by the correction scheme, for arbitrary slice position and angulation. This method of correction is unaffected by the changes in image contrast that occur due to diffusion weighting, and does not need any additional scanning time during the patient scan. It is particularly suitable for use with single-shot echo planar imaging.  相似文献   

19.
一种具有数字预加重的磁共振成像梯度波形发生器   总被引:1,自引:1,他引:0  
提出一种用于磁共振成像的高性能,高集成度基于PCI总线的数字预加重梯度波形发生器,它具有独立的X,Y,Z三通道预加重梯度波形输出,其主要特点在于此设计采用了现场可编程门阵列技术实现. 本文所述的预加重梯度发生器,其数字梯度预加重和数字逻辑模块全部集成在单片可编程芯片中,这样不但可以产生高性能的预加重梯度波形,而且可以简化磁共振成像仪的设计. 本文详细讨论了此梯度波形发生器的设计,最后给出了此设计的测试指标和实验结果.   相似文献   

20.
This paper evaluates a new, low-frequency finite-difference time-domain method applied to the problem of induced E-fields/eddy currents in the human body resulting from the pulsed magnetic field gradients in MRI. In this algorithm, a distributed equivalent magnetic current is proposed as the electromagnetic source and is obtained by quasistatic calculation of the empty coil's vector potential or measurements therein. This technique circumvents the discretization of complicated gradient coil geometries into a mesh of Yee cells, and thereby enables any type of gradient coil modelling or other complex low frequency sources. The proposed method has been verified against an example with an analytical solution. Results are presented showing the spatial distribution of gradient-induced electric fields in a multi-layered spherical phantom model and a complete body model.  相似文献   