1.
The development of a microfluidic biosensor module with fluorescence detection for the identification of pathogenic organisms and viruses is presented in this article. The microfluidic biosensor consists of a network of microchannels fabricated in polydimethylsiloxane (PDMS) substrate. The microchannels are sealed with a glass substrate and packed in a Plexiglas housing to provide connection to the macro-world and ensure leakage-free flow operation. Reversible sealing permits easy disassembly for cleaning and replacing the microfluidic channels. The fluidic flow is generated by an applied positive pressure gradient, and the module can be operated under continuous solution flow of up to 80 microL min(-1). The biosensor recognition principle is based on DNA/RNA hybridization and liposome signal amplification. Superparamagnetic beads are incorporated into the system as a mobile solid support and are an essential part of the analysis scheme. In this study, the design, fabrication and the optimization of concentrations and amounts of the different biosensor components are carried out. The total time required for an assay is only 15 min including sample incubation time. The biosensor module is designed so that it can be easily integrated with a micro total analysis system, which will combine sample preparation and detection steps onto a single chip.  相似文献   

2.
Yu X  Lv R  Ma Z  Liu Z  Hao Y  Li Q  Xu D 《The Analyst》2006,131(6):745-750
Electrochemical impedance spectroscopy (EIS) combined with a gold electrode array was developed to detect multiple antibody-antigen interactions. Hepatitis B surface antigen (HBsAg), as a model sample, was employed to evaluate the characteristics of the biosensor. The array was fabricated by immobilizing antibodies on the self-assembled molecules surface of the electrodes. The surface characteristics of the array during the binding process including the antibody-antigen conjugation and the sandwich complex with HRP-labeled antibody, as well as the precipitation layer, were characterized by atomic force microscopy (AFM) and electrochemical impedance spectroscopy, respectively. A linear relationship between electron-transfer resistance and the concentrations of HBsAg ranged from 10 pg ml(-1) to 1 ng ml(-1) and the detection limit of 10 pg ml(-1) was obtained. 100 pg ml(-1) antigen samples, such as rat IgG, HBsAg and HBeAg, as well as the antigen mixture, were incubated with the relative antibody-modified electrodes on the array. No obvious cross-talk reaction was observed. All these results confirm the feasibility of applying electrochemical impedance spectroscopy to the electrode array.  相似文献   

3.
An amperometric biosensor for phosphate ion is described that is based on a cobalt phthalocyanine modified screen-printed carbon electrode (CoPC-SPCE). The biosensor operation is based on the enzyme pyruvate oxidase (PyOd) which catalyses the oxidative decarboxylation of pyruvate, in the presence of inorganic phosphate and O2, to acetyl phosphate, hydrogen peroxide (H2O2) and CO2. The transducer allows the electrocatalytic oxidation of H2O2 in order to generate the analytical signal. The enzyme was immobilised onto the CoPC-SPCE using a sandwich format. The inner membrane was formed in situ by depositing an acetone solution containing cellulose acetate first onto the transducer surface. The enzyme and cofactors were then deposited onto this layer and allowed to dry; finally a second aliquot of the cellulose acetate solution was deposited onto the enzyme layer and allowed to dry. The biosensor was characterised by amperometry in stirred solution to produce current-voltage curves and for calibration studies. From these it was deduced that a reliable electrocatalytic response was obtained for phosphate ion; an operating potential of +0.4 V was selected for the analysis of urine samples. The precision of the response for urine analysis and recovery data for potable water suggests that the biosensor could have applications in clinical and environmental monitoring.  相似文献   

4.
Park S  Wijethunga PA  Moon H  Han B 《Lab on a chip》2011,11(13):2212-2221
For tissue engineering and regenerative medicine, cryopreservation, a technique for preserving biomaterials in the frozen state with cryoprotective agents (CPAs), is critically important for preserving engineered tissues (ETs) as well as cells necessary to create ETs. As more diverse ETs are produced using various cell types, CPAs and corresponding freeze/thaw (F/T) protocols need to be developed cell/tissue-type specifically. This is because CPAs and F/T protocols that have been successful for one cell/tissue type have proven to be difficult to adapt to other cell/tissue types. The most critical barrier to address this challenge is the inability to screen and identify CPA or CPA mixtures efficiently. In this paper, we developed an "electro-wetting-on-dielectic" (EWOD) based digital microfluidic platform to characterize and screen CPA mixtures cell-type specifically. The feasibility of the EWOD platform was demonstrated by characterizing and optimizing a mixture of dimethlysulfoxide (DMSO) and PBS for human breast cancer cell line as model CPA mixture and cell line. The developed platform multiplexed droplets of DMSO and PBS to create an array of DMSO-PBS mixtures, and mapped the phase change diagram of the mixture. After loading cell suspensions on the platform, the mixture was further screened on-chip for toxicity and cryoprotection. The results were discussed to illustrate the capabilities and limitations of the EWOD platform for cell and tissue-type specific optimization of CPA mixtures and F/T protocols.  相似文献   

5.
L Guo  Y Yin  R Huang  B Qiu  Z Lin  HH Yang  J Li  G Chen 《Lab on a chip》2012,12(20):3901-3906
The impact of chiral compounds on pharmacological and biological processes is well known. With the increasing need for enantiomerically pure compounds, effective strategies for enantioseparation and chiral discrimination are in great demand. Herein we report a simple but efficient approach for the enantioselective determination of chiral compounds based on a localized surface plasmon resonance (LSPR) biosensor integrated with a microfluidic chip. A glass microfluidic chip with an effective volume of ~0.75 μL was fabricated for this application. Gold nanorods (AuNRs) with an aspect ratio of ~2.6 were self-assembled onto the surface of the inner wall of the chip to serve as LSPR transducers, which would translate the analyte binding events into quantitative concentration information. Human α-thrombin was immobilized onto the AuNR surface for enantioselective sensing of the enantiomers of melagatran. The proposed sensor was found to be highly selective for RS-melagatran, while the binding of its enantiomer, SR-melagatran, to the sensor was inactive. Under optimal conditions, the limit of detection of this sensor for RS-melagatran was found to be 0.9 nM, whereas the presence of 10?000-fold amounts of SR-melagatran did not interfere with the detection. To the best of our knowledge, this is the first demonstration of an LSPR-based enantioselective biosensor.  相似文献   

6.
《中国化学快报》2023,34(8):108110
Residual antibiotics in food pose a serious long-term threat to human health. Therefore, an on-site visualization method for antibiotic detection is required. However, the requirements of traditional antibiotic testing methods in terms of operator proficiency and equipment cost hinder the rapid point-of-care-testing detection of suspected samples. Herein, we reported an integrated microfluidic device combining a microfluidic chip containing cruciform valves with immunochromatographic strips for the rapid detection of multiple antibiotics in milk. The rapid qualitative and quantitative analysis of four types of antibiotics (sulfonamides, β-lactams, streptomycin, and tetracyclines) was performed using mobile phone photography and mobile phone application analysis. The detection time was maintained at 10 min. The limits of detection (LODs) for the four antibiotics were 0.15, 0.12, 0.25, and 0.29 ng/mL, respectively, and the selectivity for the different antibiotics was observed even in a highly complex matrix. This device successfully integrated separation and real-time detection onto a chip and might provide a promising perspective for the detection of multiple antibiotics in milk.  相似文献   

7.
The ability to accurately control fluid transport in microfluidic devices is key for developing high‐throughput methods for single cell analysis. Making small, reproducible changes to flow rates, however, to optimize lysis and injection using pumps external to the microfluidic device are challenging and time‐consuming. To improve the throughput and increase the number of cells analyzed, we have integrated previously reported micropumps into a microfluidic device that can increase the cell analysis rate to ∼1000 cells/h and operate for over an hour continuously. In order to increase the flow rates sufficiently to handle cells at a higher throughput, three sets of pumps were multiplexed. These pumps are simple, low‐cost, durable, easy to fabricate, and biocompatible. They provide precise control of the flow rate up to 9.2 nL/s. These devices were used to automatically transport, lyse, and electrophoretically separate T‐Lymphocyte cells loaded with Oregon green and 6‐carboxyfluorescein. Peak overlap statistics predicted the number of fully resolved single‐cell electropherograms seen. In addition, there was no change in the average fluorescent dye peak areas indicating that the cells remained intact and the dyes did not leak out of the cells over the 1 h analysis time. The cell lysate peak area distribution followed that expected of an asynchronous steady‐state population of immortalized cells.  相似文献   

8.
We calculated the characteristics of a phosphoric cation exchanger and studied an accurately computable method for ion exchange capacity for a type of potentiometric titration curve. The ion exchanger was prepared by phosphorylation of a styrene‐divinylbenzene copolymer. The ion exchange capacity was 5.7 meq/g. The experimental pK values versus χ in a phosphoric cation exchanger can explain a linear equation. The ΔpK values were obtained from the slope of a linear equation. The ΔpK values were the differences of pK values between the apparent equilibrium constant at complete and zeroth neutralization of the ion exchanger. The experimental pK values at χ = 0.5 (χ:degree of neutralization of ion exchanger) showed good agreement with the theoretical data. When it was titrated with NaOH and Ba(OH)2 solutions, a good agreement between experimental and theoretical pK values for various χ was found in all potentiometric titration curves. The potentiometric titration curve near the inflection point in the case of divalent ions was changed more sharply than that for monovalent ions. The plot of ∂pH/g versus g (number of moles of alkali to 1 g of ion exchanger) was fitted to the Lorenzian distribution, from which ion exchange capacity was accurately evaluated. © 2000 John Wiley & Sons, Inc. J Polym Sci B: Polym Phys 38: 3181–3188, 2000  相似文献   

9.
Si G  Yang W  Bi S  Luo C  Ouyang Q 《Lab on a chip》2012,12(7):1389-1394
We developed a multiple-channel microfluidic device for bacterial chemotaxis detection. Some characteristics such as easy operation, parallel sample adding design and fast result readout make this device convenient for most biology labs. The characteristic feature of the design is the agarose gel channels, which serve as a semi-permeable membrane. They can stop the fluid flow and prevent bacteria getting across, but permit the diffusion of small molecules. In the device fabrication process a novel thermal-based method was used to control the shape of agarose gel in the microfluidic channel. The chemical gradient is established by diffusion which can be precisely controlled and measured. Combined with an 8-channel pipette, different attractants, repellent chemicals or different bacteria were analyzed by a two step operation with a readout time of one hour. This device may be useful in the high throughput detection of chemotaxis related molecules and genes.  相似文献   

10.
The potentiometric properties of all-solid-state nitrate-selective electrodes based on plasticized PVC and containing different types of nanosized carbon black were investigated. The use of a carbon black interlayer is shown to significantly improve the potentiometric response. The electrodes display a close-to-Nernstian slope in the range from 10?1 to 10?6 M, highly stable potentials and low membrane resistance. However, different analytical features were found depending on the type of carbon black used. The best long-term potential stability was observed for the electrode with Printex XE2-B carbon black that has a relatively high BET surface area (1000 m2?·?g?1) and an average particle size of 30 nm. Nevertheless, the electrodes with the Vulcan XC-72 (BET surface: 240 m2?·?g?1; average size: 55 nm) showed the most repeatable and reproducible standard potential. The lowest detection limit for nitrate (2.5·10?7 M) is observed for an electrode containing Vulcan XC-72.
Figure
The comparison of the potentiometric behavior of all-solid state ion-selective electrodes with the different types of the furnace carbon black is presented by employing the nitrate-selective membrane. The electrodes display a close-to-Nernstian slope, highly stable potentials and low membrane resistance  相似文献   

11.
This paper describes a microfluidic platform for the on-demand generation of multiple aqueous droplets, with varying chemical contents or chemical concentrations, for use in droplet based experiments. This generation technique was developed as a complement to existing techniques of continuous-flow (streaming) and discrete-droplet generation by enabling the formation of multiple discrete droplets simultaneously. Here sets of droplets with varying chemical contents can be generated without running the risk of cross-contamination due to the isolated nature of each supply inlet. The use of pressure pulses to generate droplets in parallel is described, and the effect of droplet size is examined in the context of flow rates and surfactant concentrations. To illustrate this technique, an array of different dye-containing droplets was generated, as well as a set of droplets that displayed a concentration gradient of a fluorescent dye.  相似文献   

12.
Dimov IK  Kijanka G  Park Y  Ducrée J  Kang T  Lee LP 《Lab on a chip》2011,11(16):2701-2710
Just as the Petri dish has been invaluable to the evolution of biomedical science in the last 100 years, microfluidic cell assay platforms have the potential to change significantly the way modern biology and clinical science are performed. However, an evolutionary process of creating an efficient microfluidic array for many different bioassays is necessary. Specifically for a complete view of a cell response it is essential to incorporate cytotoxic, protein and gene analysis on a single system. Here we present a novel cellular and molecular analysis platform, which allows access to gene expression, protein immunoassay, and cytotoxicity information in parallel. It is realized by an integrated microfluidic array plate (iMAP). The iMAP enables sample processing of cells, perfusion based cell culture, effective perturbation of biologic molecules or drugs, and simultaneous, real-time optical analysis for different bioassays. The key features of the iMAP design are the interface of on-board gravity driven flow, the open access input fluid exchange and the highly efficient sedimentation based cell capture mechanism (~100% capture rates). The operation of the device is straightforward (tube and pump free) and capable of handling dilute samples (5-cells per experiment), low reagent volumes (50 nL per reaction), and performing single cell protein and gene expression measurements. We believe that the unique low cell number and triple analysis capabilities of the iMAP platform can enable novel dynamic studies of scarce cells.  相似文献   

13.
Electronic tongue based on an array of metallic potentiometric sensors   总被引:1,自引:0,他引:1  
An electronic tongue system based on the array of six metallic potentiometric sensors (metallic wires) was developed and utilized for discrimination of foodstuffs: several types of vinegar and fruit juices. Copper, tin, iron, aluminum, brass and stainless steel wires were included in the array and supplemented by pH glass electrode. The response of potentiometric metallic sensors towards various organic acids has been studied and possible sensitivity mechanisms were discussed. Overall potential changes of metallic sensors were exanimate as complex mixed signals influenced by several components presenting in analyte employing chemometric approach. The multisensor array of such a type can be useful for several applications since of simplicity in handling, low cost of sensors and easy measure procedure.  相似文献   

14.
Equations are proposed to process the results of potentiometric analysis by the methods of two and multiple standard additions in the case when the slope of the electrode response is known. In the analysis of 1 × 10?3 to 1 × 10?5 M bromide ion model solutions, RSD is within 7–8% when the method of two additions is used and within 3–7% when the method of multiple additions is used. The error of determinations is at most 5%.  相似文献   

15.
Palytoxin (PLTX), a polyether marine toxin originally isolated from the zoanthid Palythoa toxica, is one of the most toxic non-protein substances known. Fatal poisonings have been linked to ingestion of PLTX-contaminated seafood, and effects in humans have been associated with dermal and inhalational exposure to PLTX containing organisms and waters. Additionally, PLTX co-occurrence with other well-characterized seafood toxins (e.g., ciguatoxins, saxitoxins, tetrodotoxin) has hindered direct associations of PLTX to seafood-borne illnesses. There are currently no validated methods for the quantitative detection of PLTX(s). As such, a well-characterized, robust, specific analytical technique is needed for the detection of PLTX(s) in source organisms, surrounding waters, and clinical samples. Surface plasmon resonance (SPR) biosensors are ideally suited for antibody characterization and quantitative immunoassay detection. Herein, we describe a newly developed SPR assay for PLTX. An anti-mouse substrate was used to characterize the kinetic values for a previously developed monoclonal anti-PLTX. The characterized antibody was then incorporated into a sensitive, rapid, and selective PLTX assay. Buffer type, flow rate, analyte-binding time, and regeneration conditions were optimized for the antibody–PLTX system. Cross-reactivity to potentially co-occurring seafood toxins was also evaluated. We show that this optimized assay is capable of measuring low- to sub-ng/mL PLTX levels in buffer and two seafood matrices (grouper and clam). Preliminary results indicate that this SPR biosensor assay allows for (1) rapid characterization of antibodies and (2) rapid, sensitive PLTX concentration determination in seafood matrices. Method development information contained herein may be broadly applied to future PLTX detection and/or antibody characterization efforts.  相似文献   

16.
A disk-shaped microfluidic device (lab-on-a-Disk) was developed to allow the evaluation of mental stress. As a standard sample, secretory immunoglobulin A (sIgA), which is a candidate marker of mental stress, was measured by a heterogeneous enzyme immunoassay (EIA) on the lab-on-a-Disk. Centrifugal force provided a microfluidic control on the lab-on-a-Disk. We examined the relationship between the rotational speed, the channel profile, and the position of the microfluidic chambers from the center of rotation to manipulate sample solutions into each reaction reservoir through microchannels sequentially, i.e., retain in a reservoir or flow into a subsequent reservoir. A single glass bead with immobilized sIgA on its surface was injected into a reservoir for a competitive antigen-antibody reaction, and applied to a specific surface in a heterogeneous assay. It is expected that the lab-on-a-Disk would be suitable for miniaturization and automation of the processes in EIA compared with a conventional EIA using a titer plate.  相似文献   

17.
In this paper we propose the construction and application of a portable multi-purpose biosensor array for the simultaneous detection of a wide range of endocrine disruptor chemicals (EDCs), based on the recognition operated by various enzymes and microorganisms. The developed biosensor combines both electrochemical and optical transduction systems, in order to increase the number of chemical species which can be monitored. Considering to the maximum residue level (MRL) of contaminants established by the European Commission, the biosensor system was able to detect most of the chemicals analysed with very high sensitivity. In particular, atrazine and diuron were detected with a limit of detection of 0.5 nM, with an RSD% less than 5%; paraoxon and chlorpyrifos were revealed with a detection of 5 μM and 4.5 μM, respectively, with an RSD% less than 6%; catechol and bisphenol A were identified with a limit of detection of 1 μM and 35 μM respectively, with an RSD% less than 5%.  相似文献   

18.
This work describes the development of flow analysis microsystems with integrated fluorimetric detection cells. Channels (width of 300–540 μm and depth of 200–590 μm) were manufactured by deep-UV lithography in urethane–acrylate (UA) resin. Plastic optical fibers (diameter of 250 μm) were coupled to a 2.0-mm-long detection channel in order to guide the excitation radiation from an LED (470 nm) and collect the emitted radiation at a right angle towards a photomultiplier. A single-line miniaturized system, with a total internal volume of 10.4 μL, was evaluated by means of standard fluorescein solutions (0.53–2.66 μmol L−1, pH 8.5). The analytical signals presented a linear relationship in the concentration range studied, with a relative standard deviation of 1.9% (n = 5), providing a detection limit of 0.37 μmol L−1 and an analytical frequency of 60 samples/h, using a flow rate of 60 μL min−1. Optical microscopy images and videos acquired in real time for the hydrodynamic injection of 130 and 320 nL of sample solutions indicated the good performance of the proposed sampling strategy. Another microsystem with a total internal volume of 38 μL was developed, incorporating a confluence point for two solutions. This device was applied to the determination of the total concentration of Ca2+ and Mg2+ in commercial mineral waters using the calcein method. Microscopy images and videos demonstrated the mixing efficiency of the solutions in the microchannels. A linear relationship was observed for the analytical signal in the Ca2+ concentration range from 25 to 125 μmol L−1, with relative standard deviations of 3.5%. The analysis of mineral waters with the proposed system provided results that did not differ significantly from those obtained by the EDTA titration method at a confidence level of 95%. These results demonstrate the viability of developing micro flow injection systems with an integrated fluorimetric detection cell.   相似文献   

19.
Room-temperature (RT) protein crystallography provides significant information to elucidate protein function under physiological conditions. In particular, contrary to typical binding assays, X-ray crystal structure analysis of a protein–ligand complex can determine the three-dimensional (3D) configuration of its binding site. This allows the development of effective drugs by structure-based and fragment-based (FBDD) drug design. However, RT crystallography and RT crystallography-based protein–ligand complex analyses require the preparation and measurement of numerous crystals to avoid the X-ray radiation damage. Thus, for the application of RT crystallography to protein–ligand complex analysis, the simultaneous preparation of protein–ligand complex crystals and sequential X-ray diffraction measurement remain challenging. Here, we report an RT crystallography technique using a microfluidic protein crystal array device for protein–ligand complex structure analysis. We demonstrate the microfluidic sorting of protein crystals into microwells without any complicated procedures and apparatus, whereby the sorted protein crystals are fixed into microwells and sequentially measured to collect X-ray diffraction data. This is followed by automatic data processing to calculate the 3D protein structure. The microfluidic device allows the high-throughput preparation of the protein–ligand complex solely by the replacement of the microchannel content with the required ligand solution. We determined eight trypsin–ligand complex structures for the proof of concept experiment and found differences in the ligand coordination of the corresponding RT and conventional cryogenic structures. This methodology can be applied to easily obtain more natural structures. Moreover, drug development by FBDD could be more effective using the proposed methodology.

Room temperature protein crystallography and its application to protein–ligand complex structure analysis was demonstrated using a microfluidic protein crystal array device.  相似文献   

20.
A microfluidic based experimental methodology has been developed that offers a biomimetic microenvironment in which pseudo in vivo tissue studies can be carried out under in vitro conditions. Using this innovative technique, which utilizes the inherent advantages of microfluidic technology, liver tissue has been kept in a viable and functional state for over 70 h during which time on-chip cell lysis has been repeatedly performed. Tissue samples were also disaggregated in situ on-chip into individual primary cells, using a collagenase digestion procedure, enabling further cell analysis to be carried out off-line. It is anticipated that this methodology will have a wide impact on biological and clinical research in fields such as cancer prognosis and treatment, drug development and toxicity, as well as enabling better fundamental research into tissue/cell processes.  相似文献   