1.
The ESRF synchrotron beamline ID22, dedicated to hard X‐ray microanalysis and consisting of the combination of X‐ray fluorescence, X‐ray absorption spectroscopy, diffraction and 2D/3D X‐ray imaging techniques, is one of the most versatile instruments in hard X‐ray microscopy science. This paper describes the present beamline characteristics, recent technical developments, as well as a few scientific examples from recent years of the beamline operation. The upgrade plans to adapt the beamline to the growing needs of the user community are briefly discussed.  相似文献   

2.
Owing to its extreme sensitivity, quantitative mapping of elemental distributions via X‐ray fluorescence microscopy (XFM) has become a key microanalytical technique. The recent realisation of scanning X‐ray diffraction microscopy (SXDM) meanwhile provides an avenue for quantitative super‐resolved ultra‐structural visualization. The similarity of their experimental geometries indicates excellent prospects for simultaneous acquisition. Here, in both step‐ and fly‐scanning modes, robust, simultaneous XFM‐SXDM is demonstrated.  相似文献   

3.
In GaAs nanowires grown along the cubic [111]c direction, zinc blende and wurtzite arrangements have been observed in their stacking sequence, since the energetic barriers for nucleation are typically of similar order of magnitude. It is known that the interplanar spacing of the (111)c Ga (or As) planes in the zinc blende polytype varies slightly from the wurtzite polytype. However, different values have been reported in the literature. Here, the ratio of the interplanar spacing of these polytypes is extracted based on X‐ray diffraction measurements for thin GaAs nanowires with a mean diameter of 18–25 nm. The measurements are performed with a nano‐focused beam which facilitates the separation of the scattering of nanowires and of parasitic growth. The interplanar spacing of the (111)c Ga (or As) planes in the wurtzite arrangement in GaAs nanowires is observed to be 0.66% ± 0.02% larger than in the zinc blende arrangement.  相似文献   

4.
A microfocus X‐ray fluorescence spectroscopy beamline (BL‐16) at the Indian synchrotron radiation facility Indus‐2 has been constructed with an experimental emphasis on environmental, archaeological, biomedical and material science applications involving heavy metal speciation and their localization. The beamline offers a combination of different analytical probes, e.g. X‐ray fluorescence mapping, X‐ray microspectroscopy and total‐external‐reflection fluorescence characterization. The beamline is installed on a bending‐magnet source with a working X‐ray energy range of 4–20 keV, enabling it to excite K‐edges of all elements from S to Nb and L‐edges from Ag to U. The optics of the beamline comprises of a double‐crystal monochromator with Si(111) symmetric and asymmetric crystals and a pair of Kirkpatrick–Baez focusing mirrors. This paper describes the performance of the beamline and its capabilities with examples of measured results.  相似文献   

5.
A confocal full‐field X‐ray microscope has been developed for use as a novel three‐dimensional X‐ray imaging method. The system consists of an X‐ray illuminating `sheet‐beam' whose beam shape is micrified only in one dimension, and an X‐ray full‐field microscope whose optical axis is normal to the illuminating sheet beam. An arbitral cross‐sectional region of the object is irradiated by the sheet‐beam, and secondary X‐ray emission such as fluorescent X‐rays from this region is imaged simultaneously using the full‐field microscope. This system enables a virtual sliced image of a specimen to be obtained as a two‐dimensional magnified image, and three‐dimensional observation is available only by a linear translation of the object along the optical axis of the full‐field microscope. A feasibility test has been carried out at beamline 37XU of SPring‐8. Observation of the three‐dimensional distribution of metallic inclusions in an artificial diamond was performed.  相似文献   

6.
Here, soft X‐ray synchrotron radiation transmitted through microchannel plates is studied experimentally. Fine structures of reflection and XANES Si L‐edge spectra detected on the exit of silicon glass microcapillary structures under conditions of total X‐ray reflection are presented and analyzed. The phenomenon of the interaction of channeling radiation with unoccupied electronic states and propagation of X‐ray fluorescence excited in the microchannels is revealed. Investigations of the interaction of monochromatic radiation with the inner‐shell capillary surface and propagation of fluorescence radiation through hollow glass capillary waveguides contribute to the development of novel X‐ray focusing devices in the future.  相似文献   

7.
The coupling and propagation of electromagnetic waves through planar X‐ray waveguides (WG) with vacuum gap and Si claddings are analyzed in detail, starting from the source and ending at the detector. The general case of linearly tapered WGs (i.e. with the entrance aperture different from the exit one) is considered. Different kinds of sources, i.e. synchrotron radiation and laboratory desk‐top sources, have been considered, with the former providing a fully coherent incoming beam and the latter partially coherent beams. It is demonstrated that useful information about the parameters of the WG can be derived, comparing experimental results with computer simulation based on analytical solutions of the Helmholtz equation which take into account the amplitude and phase matching between the standing waves created in front of the WG, and the resonance modes propagating into the WG.  相似文献   

8.
An X‐ray dynamical diffraction Fraunhofer holographic scheme is proposed. Theoretically it is shown that the reconstruction of the object image by visible light is possible. The spatial and temporal coherence requirements of the incident X‐ray beam are considered. As an example, the hologram recording as well as the reconstruction by visible light of an absolutely absorbing wire are discussed.  相似文献   

9.
Transmission X‐ray mirrors have been fabricated from 300–400 nm‐thick low‐stress silicon nitride windows of size 0.6 mm × 85 mm. The windows act as a high‐pass energy filter at grazing incidence in an X‐ray beam for the beam transmitted through the window. The energy cut‐off can be selected by adjusting the incidence angle of the transmission mirror, because the energy cut‐off is a function of the angle of the window with respect to the beam. With the transmission mirror at the target angle of 0.22°, a 0.3 mm × 0.3 mm X‐ray beam was allowed to pass through the mirror with a cut‐off energy of 10 keV at the Cornell High Energy Synchrotron Source. The energy cut‐off can be adjusted from 8 to 12 keV at an angle of 0.26° to 0.18°, respectively. The observed mirror transmittance was above 80% for a 300 nm‐thick film.  相似文献   

10.
Combined X‐ray photon correlation spectroscopy (XPCS) and diffracted X‐ray tracking (DXT) measurements of carbon‐black nanocrystals embedded in styrene–butadiene rubber were performed. From the intensity fluctuation of speckle patterns in a small‐angle scattering region (XPCS), dynamical information relating to the translational motion can be obtained, and the rotational motion is observed through the changes in the positions of DXT diffraction spots. Graphitized carbon‐black nanocrystals in unvulcanized styrene–butadiene rubber showed an apparent discrepancy between their translational and rotational motions; this result seems to support a stress‐relaxation model for the origin of super‐diffusive particle motion that is widely observed in nanocolloidal systems. Combined measurements using these two techniques will give new insights into nanoscopic dynamics, and will be useful as a microrheology technique.  相似文献   

11.
The morphological change of silver nano‐particles (AgNPs) exposed to an intense synchrotron X‐ray beam was investigated for the purpose of direct nano‐scale patterning of metal thin films. AgNPs irradiated by hard X‐rays in oxygen ambient were oxidized and migrated out of the illuminated region. The observed X‐ray induced oxidation was utilized to fabricate nano‐scale metal line patterns using sectioned WSi2/Si multilayers as masks. Lines with a width as small as 21 nm were successfully fabricated on Ag films on silicon nitride. Au/Ag nano‐lines were also fabricated using the proposed method.  相似文献   

12.
The possibility of splitting a thin (e.g. undulator) X‐ray beam based on diffraction–refraction effects is discussed. The beam is diffracted from a crystal whose diffracting surface has the shape of a roof with the ridge lying in the plane of diffraction. The crystal is cut asymmetrically. One half of the beam impinges on the left‐hand part of the roof and the other half impinges on the right‐hand side of the roof. Owing to refraction the left part of the beam is deviated to the left whereas the right part is deviated to the right. The device proposed consists of two channel‐cut crystals with roof‐like diffraction surfaces; the crystals are set in a dispersive position. The separation of the beams after splitting is calculated at a distance of 10 m from the crystals for various asymmetry and inclination angles. It is shown that such a splitting may be utilized for long beamlines. Advantages and disadvantages of this method are discussed.  相似文献   

13.
Discovery of new materials drives the deployment of new technologies. Complex technological requirements demand precisely tailored material functionalities, and materials scientists are driven to search for these new materials in compositionally complex and often non‐equilibrium spaces containing three, four or more elements. The phase behavior of these high‐order composition spaces is mostly unknown and unexplored. High‐throughput methods can offer strategies for efficiently searching complex and multi‐dimensional material genomes for these much needed new materials and can also suggest a processing pathway for synthesizing them. However, high‐throughput structural characterization is still relatively under‐developed for rapid material discovery. Here, a synchrotron X‐ray diffraction and fluorescence experiment for rapid measurement of both X‐ray powder patterns and compositions for an array of samples in a material library is presented. The experiment is capable of measuring more than 5000 samples per day, as demonstrated by the acquisition of high‐quality powder patterns in a bismuth–vanadium–iron oxide composition library. A detailed discussion of the scattering geometry and its ability to be tailored for different material systems is provided, with specific attention given to the characterization of fiber textured thin films. The described prototype facility is capable of meeting the structural characterization needs for the first generation of high‐throughput material genomic searches.  相似文献   

14.
Combined measurements of X‐ray absorption and fluorescence have been performed in jets of pure and diluted argon gas to demonstrate the feasibility of using X‐ray fluorescence to study turbulent mixing. Measurements show a strong correspondence between the absorption and fluorescence measurements for high argon concentration. For lower argon concentration, fluorescence provides a much more robust measurement than absorption. The measurements agree well with the accepted behavior of turbulent jets.  相似文献   

15.
A distributed fast‐acquisition system for synchronized multi‐technique experiments is presented, in which the collection of metadata and the asynchronous merging of large data volumes from multiple detectors are managed as part of the data collection process. This fast continuous scanning scheme, named FLYSCAN, enables measurement of microscopy data on a timescale of milliseconds per pixel. Proof‐of‐principle multi‐technique experiments, namely scanning X‐ray fluorescence spectrometry combined with absorption, differential phase contrast and dark‐field imaging, have been performed on biological and geological samples.  相似文献   

16.
Third‐generation synchrotron radiation sources pose difficult challenges for energy‐dispersive detectors for XAFS because of their count rate limitations. One solution to this problem is the bent crystal Laue analyzer (BCLA), which removes most of the undesired scatter and fluorescence before it reaches the detector, effectively eliminating detector saturation due to background. In this paper experimental measurements of BCLA performance in conjunction with a 13‐element germanium detector, and a quantitative analysis of the signal‐to‐noise improvement of BCLAs are presented. The performance of BCLAs are compared with filters and slits.  相似文献   

17.
Using the scanning transmission X‐ray microscope at BESSY II, colloidal structures from a Chernozem soil have been studied with a spatial resolution around 60 nm and a spectral resolution of 1700 at the K‐absorption edge of carbon. Elemental mapping has been used to determine the distribution of organic matter within the colloidal structures. Spectra have been extracted from image stacks to obtain information about the chemical state. For the analysis of the latter, principal component analysis and cluster analysis have been applied. It was possible, for example, to discriminate clay particles against organic components.  相似文献   

18.
The properties of X‐ray vacuum‐gap waveguides (WGs) with additional periodic structure on one of the reflecting walls are studied. Theoretical considerations, numerical simulations and experimental results confirm that the periodic structure imposes additional conditions on efficient propagation of the electromagnetic field along the WGs. The transmission is maximum for guided modes that possess sufficient phase synchronism with the periodic structure (here called `super‐resonances'). The field inside the WGs is essentially given at low incidence angle by the fundamental mode strongly coupled with the corresponding phased‐matched mode. Both the simulated and the experimental diffraction patterns show in the far field that propagation takes place essentially only for low incidence angles, confirming the mode filtering properties of the structured X‐ray waveguides.  相似文献   

19.
X‐ray fluorescence nanotomography provides unprecedented sensitivity for studies of trace metal distributions in whole biological cells. Dose fractionation, in which one acquires very low dose individual projections and then obtains high statistics reconstructions as signal from a voxel is brought together (Hegerl & Hoppe, 1976), requires accurate alignment of these individual projections so as to correct for rotation stage runout. It is shown here that differential phase contrast at 10.2 keV beam energy offers the potential for accurate cross‐correlation alignment of successive projections, by demonstrating that successive low dose, 3 ms per pixel, images acquired at the same specimen position and rotation angle have a narrower and smoother cross‐correlation function (1.5 pixels FWHM at 300 nm pixel size) than that obtained from zinc fluorescence images (25 pixels FWHM). The differential phase contrast alignment resolution is thus well below the 700 nm × 500 nm beam spot size used in this demonstration, so that dose fractionation should be possible for reduced‐dose, more rapidly acquired, fluorescence nanotomography experiments.  相似文献   

20.
A bent‐crystal spectrometer based on the Rowland circle geometry has been installed and tested on the BM30b/FAME beamline at the European Synchrotron Radiation Facility to improve its performances. The energy resolution of the spectrometer allows different kinds of measurements to be performed, including X‐ray absorption spectroscopy, resonant inelastic X‐ray scattering and X‐ray Raman scattering experiments. The simplicity of the experimental device makes it easily implemented on a classical X‐ray absorption beamline. This improvement in the fluorescence detection is of particular importance when the probed element is embedded in a complex and/or heavy matrix, for example in environmental sciences.  相似文献   