首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 922 毫秒
1.
An efficient, simple, validated, analytical and semi‐preparative HPLC method has been developed for direct enantioresolution of (RS)‐Ketorolac (Ket) using monochloro‐methylated derivatives of cellulose and amylose, i.e. cellulose (tris‐3‐chloro‐4‐methylphenylcarbamate) and amylose (tris‐5‐chloro‐2‐methylphenylcarbamate) as chiral stationary phases (CSPs) with photo diode array detection at 320 nm. Enantioresolution was carried out in samples of human plasma spiked with (RS)‐Ket under normal and reversed‐phase elution modes with suitable mobile phase compositions. The effect of nature of alcohols (MeOH, EtOH, PrOH and n‐BuOH) and other solvents (MeCN and MeOH) as organic modifiers in the mobile phase was investigated on the separation performance of two CSPs in terms of retention and separation of enantiomers. The best resolution was observed on cellulose‐based CSP using EtOH, while using 2‐PrOH (15%) and amylose‐based CSP obtained the highest retention. Under reversed‐phase elution mode the best enantioseparation was observed using 30% MeCN with ammonium formate buffer. The elution order of enantiomers was ascertained by determining specific rotations. The limit of detection and quantitation values were 5 and 15.5 ng/mL for each enantiomer of (RS)‐Ket, respectively. Copyright © 2016 John Wiley & Sons, Ltd.  相似文献   

2.
The separation of the enantiomers of 17 chiral sulfoxides was studied on polysaccharide‐based chiral columns in polar organic mobile phases. Enantiomer elution order (EEO) was the primary objective in this study. Two of the six chiral columns, especially those based on amylose tris(3,5‐dimethylphenylcarbamate) and cellulose tris(4‐chloro‐3‐methylphenylcarbamate) (Lux Cellulose‐4) proved to be most successful in the separation of the enantiomers of the studied sulfoxides. Interesting examples of EEO reversal were observed depending on the chiral selector or the composition of the mobile phase. For instance, the R‐(+) enantiomer of lansoprazole eluted before the S‐(?) enantiomer on Lux Cellulose‐1 in both methanol or ethanol as the mobile phase, while the elution order was opposite in the same eluents on amylose tris(3,5‐dimethylphenylcarbamate) with the S‐(?) enantiomer eluting before the R‐(+) enantiomer. The R‐(+) enantiomer of omeprazole eluted first on Lux Amylose‐2 in methanol but it was second when acetonitrile was used as the mobile phase with the same chiral selector. Several other examples of reversal in EEO were observed in this study. An interesting example of the separation of four stereoisomers of phenaminophos sulfoxide containing chiral sulfur and phosphor atoms is also reported here.  相似文献   

3.
The resolving power of a new commercial polysaccharide‐based chiral stationary phase, Sepapak‐4, with cellulose tris(4‐chloro‐3‐methylphenylcarbamate) coated on silica microparticles as chiral selector, was evaluated toward the enantioseparation of ten basic drugs with widely different structures and hydrophobic properties, using ACN as the main component of the mobile phase. A multivariate approach (experimental design) was used to screen the factors (temperature, n‐hexane content, acidic and basic additives) likely to influence enantioresolution. Then, the optimization was performed using a face‐centered central composite design. Complete enantioseparation could be obtained for almost all tested chiral compounds, demonstrating the high chiral discrimination ability of this chiral stationary phase using polar organic mobile phases made up of ACN and containing an acidic additive (TFA or formic acid), 0.1% diethylamine and n‐hexane. These results clearly illustrate the key role of the nature of the acidic additive in the mobile phase.  相似文献   

4.
An enantioselective method was developed for the simultaneous detection of five chiral fungicides in soil, including fenbuconazole ( 1 ), tetraconazole ( 2 ), nuarimol ( 3 ), triticonazole ( 4 ), and simeconazole ( 5 ) by LC–MS/MS on a chiral stationary phase of cellulose tris‐(3‐chloro‐4‐methylphenylcarbamate) with a gradient elution. A new multifunctional filter was designed to simplify the QuEChERS (where QuEChERS is quick, easy, cheap, effective, rugged, and safe) method by simultaneous cleanup and filtration when the sample extracts were directly passed through it. Good linearities (R2 > 0.9980) were obtained in the range 0.005–2.5 mg/L, and the recovery rates were 77.4–103.6% with RSDs of 0.7–12.2% for intraday precision and 1.2–11.0% for interday precision. The LODs and LOQs for all enantiomers were in the range 0.1–0.2 and 0.25–0.5 μg/kg, respectively. The analysis of the incubated soil suggests that this method is reliable and practical for the stereoselective detection of chiral fungicides.  相似文献   

5.
In this work, a novel polysaccharide‐based chiral stationary phase, cellulose tris(4‐chloro‐3‐methylphenylcarbamate), also called Sepapak 4 has been evaluated for the chiral separation of amlodipine (AML) and its two impurities. AML is a powerful vasodilatator drug used for the treatment of hypertension. Capillary columns of 100 μm id packed with the chiral stationary phase were used for both nano‐LC and CEC experiments. The optimization of the mobile phase composed of ACN/water, (90:10, v/v) containing 15 mM ammonium borate pH 10.0 in nano‐LC allowed the chiral separation of AML and the two impurities, but not in a single run. With the purpose to obtain the separation of the three pairs of enantiomers simultaneously, CEC analyses were performed in the same conditions achieving better enantioresolution and higher separation efficiencies for each compound. To fully resolve the mixture of six enantiomers, parameters such as buffer pH and concentration sample injection have been then investigated. A mixture of ACN/water (90:10, v/v) containing 5 mM ammonium borate buffer pH 9.0 enabled the complete separation of the three couples of enantiomers in less than 30 min. The optimized CEC method was therefore validated and applied to the analysis of pharmaceutical formulation declared to contain only AML racemate.  相似文献   

6.
The discrimination ability of three cellulose-based chiral stationary phases (CSPs) was evaluated towards the enantiomers of basic drugs, using ACN as the main solvent in polar organic mobile phases. The study was focused on CSPs containing cellulose tris(3-chloro-4-methylphenylcarbamate) (3-Cl-4-MePC), cellulose tris(4-chloro-3-methylphenylcarbamate) (4-Cl-3-MePC) or cellulose tris(3,5-dichlorophenylcarbamate) (3,5-diClPC) as the chiral selector. The behaviour of these CSPs was studied systematically in order to investigate the influence of the presence and position of the chlorine substituents on the phenylcarbamate moieties on the retention and resolution of the enantiomers. The evaluation was made with three different generic mobile phases, namely ACN/0.1%DEA/0.1% TFA (DEA, diethylamine), ACN/0.1%DEA/0.2% FA and ACN/0.1%DEA/0.2%AcA, deduced from the previous study. The nature of the acidic additive and of the chiral selector was found to be particularly important for the retention and enantioresolution of these basic compounds. High-resolution values could be obtained for most studied enantiomers with these CSPs, clearly demonstrating the interest of using them in combination with polar organic mobile phases. However, significant differences in enantioresolution between the CSPs have been observed for many compounds, indicating that these phases seem to be quite complementary.  相似文献   

7.
In the present study, an in silico methodology able to define the binding modes adopted by carnosine enantiomers in the setting of the chiral recognition process is described. The inter‐ and intramolecular forces involved in the enantioseparation process with the Teicoplanin A2‐2 chiral selector and carnosine as model compound are successfully identified. This approach fully rationalizes, at a molecular level, the (S) < (R) enantiomeric elution order obtained under reversed‐phase conditions. Consistent explanations were achieved by managing molecular dynamics results with advanced techniques of data analysis. As a result, the time‐dependent identification of all the interactions simultaneously occurring in the chiral selector‐enantiomeric analyte binding process was obtained. Accordingly, it was found that only (R)‐carnosine is able to engage a stabilizing charge–charge interaction through its ionized imidazole ring with the carboxylate counter‐part on the chiral selector. Instead, (S)‐carnosine establishes intramolecular contacts between its ionized functional groups, that limit its conformational freedom and impair the association with the chiral selector unit.  相似文献   

8.
A simple, sensitive, and stability indicating isocratic reverse phase high performance liquid chromatography method has been developed, optimized and validated for the separation and quantification of S‐enantiomer in linagliptin (R‐enantiomer) drug substance. Enantiomeric separation was achieved on a Cellulose tris(4‐chloro‐3‐methylphenylcarbamate) stationary phase. Mobile phase consists of aqueous diammonium hydrogen phosphate buffer and acetonitrile in the ratio of 35:65 v/v. Isocratic elution was performed at a flow rate of 1.0 mL/min, the column oven temperature was set at 40°C and detection was at 226 nm. The resolution between R and S enantiomers is found to be more than 4.0. The impact of mobile phase composition, pH of buffer and temperature on the resolution has been studied. The detector response is found to be linear over the concentration range of 0.17–1.7 μg/mL. LOD and LOQ levels of S‐enantiomer are found to be 0.057 and 0.172 μg/mL respectively. The recovery of S‐enantiomer is 99.8% w/w. The proposed method is validated for specificity, precision, linearity, accuracy and robustness.  相似文献   

9.
Highly N‐deacetylated chitosan was chosen as a natural chiral origin for the synthesis of the selectors of chiral stationary phases. Therefore, chitosan was firstly acylated by various alkyl chloroformates yielding chitosan alkoxyformamides, and then these resulting products were further derivatized with 4‐methylphenyl isocyanate to afford chitosan bis(4‐methylphenylcarbamate)‐(alkoxyformamide). A series of chiral stationary phases was prepared by coating these derivatives on 3‐aminopropyl silica gel. The content of the derivatives on the chiral stationary phases was nearly 20% by weight. The chiral stationary phases prepared from chitosan bis(4‐methylphenylcarbamate)‐(ethoxyformamide) and chitosan bis(4‐methylphenylcarbamate)‐(isopropoxyformamide) comparatively showed better enantioseparation capability than those prepared from chitosan bis(4‐methylphenylcarbamate)‐(n‐pentoxyformamide) and chitosan bis(4‐methylphenylcarbamate)‐(benzoxyformamide). The tolerance against organic solvents of the chiral stationary phase of chitosan bis(4‐methylphenylcarbamate)‐(ethoxyformamide) was investigated, and the results revealed that this phase can work in 100% ethyl acetate and 100% chloroform mobile phases. Because as‐synthesized chiral selectors did not dissolve in many common organic solvents, the corresponding chiral stationary phases can be utilized in a wider range of mobile phases in comparison with conventional coating type chiral stationary phases of cellulose and amylose derivatives.  相似文献   

10.
Recycling high‐speed counter‐current chromatography was successfully applied to the preparative separation of oxybutynin enantiomers. The two‐phase solvent system consisted of n‐hexane, methyl tert‐butyl ether, and 0.1 mol/L phosphate buffer solution (pH = 5.0) with the volume ratio of 6:4:10. Hydroxypropyl‐β‐cyclodextrin was employed as the chiral selector. The influence of factors on the chiral separation process, including the concentration of chiral selector, the equilibrium temperature, the pH value of the aqueous phase were investigated. Under optimum separation conditions, 15 mg of oxybutynin racemate was separated with the purities of both the enantiomers over 96.5% determined by high‐performance liquid chromatography. Recovery for the target compounds reached 80–82% yielding 6.00 mg of (R)‐oxybutynin and 6.15 mg of (S)‐oxybutynin. Technical details for recycling elution mode were discussed.  相似文献   

11.
The enantiomeric resolution of a series of 20 asymmetric sulfoxides was systematically investigated by HPLC using multimodal elution with amylose trisR(S)-1-phenylethylcarbamate], amylose tris(3,5-dimethoxyphenylcarbamate) and amylose and cellulose tris(3,5-dimethylphenylcarbamate) phases. The sulfoxide series was composed of aromatic, olefinic and ketosulfoxides, sulfinyl acids and esters. This work has shown that enantioselectivity and enantioresolution of the polysaccharide-based columns can be achieved by changing the type and composition of the mobile phase, widening the applicability of these chiral phases.  相似文献   

12.
The stereoisomers of 1,2,3,4‐tetrahydroisoquinoline amino alcohol analogues and derivatives thereof were separated in normal‐phase mode on chiral stationary phases based on preprepared silica coated with cellulose tris‐(3,5‐dimethylphenyl carbamate), cellulose tris‐(3‐chloro‐4‐methylphenyl carbamate), cellulose tris‐(4‐methylbenzoate) or cellulose tris‐(4‐chloro‐3‐methylphenyl carbamate). On all the investigated chiral columns, the retention and the enantioseparation were influenced by the nature and the concentrations of the mobile phase components and additives, and also the temperature. Experiments were performed in the temperature range 10–50°C. Thermodynamic parameters were calculated from plots of lnα vs 1/T. On these polysaccharide‐based chiral columns, both enthalpy‐driven separations and entropy‐controlled enantioseparations were observed. The latter was advantageous with regard to the shorter retention and greater selectivity at high temperature. The sequence of elution of the stereoisomers was determined in all cases. Copyright © 2014 John Wiley & Sons, Ltd.  相似文献   

13.
Chiral high‐performance liquid chromatography separation of two recently synthesized liquid crystalline materials C1 and C2 was studied in the reversed‐phase mode. Both materials have an azo‐moiety and one chiral center in their molecular structures. They were available in racemic and pure S forms. For the enantiomeric separations, a Chiralpak AY‐RH stationary phase based on amylose tris(5‐chloro‐2‐methylphenylcarbamate) coated on 5 μm silica was used. The compounds were analyzed in both of their possible forms, the more thermodynamically stable E form and the labile Z form. The conditions and time scale of the UV‐induced E to Z transition were briefly evaluated. Under the optimized conditions, we were able to baseline separate S and R enantiomers of both of the studied materials not only in their E forms, but also in their Z forms. In comparison to the separation in the normal‐phase mode, which we have reported recently, the resolution in the reversed‐phase mode is significantly better. Interestingly, peak reversal was noticed for the S and R enantiomers when the separation was carried out with E versus Z forms of both compounds.  相似文献   

14.
The separation of the stereoisomers of 23 chiral basic agrochemicals was studied on six different polysaccharide‐based chiral columns in high‐performance liquid chromatography with various polar organic mobile phases. Along with the successful separation of analyte stereoisomers, emphasis was placed on the effect of the chiral selector and mobile phase composition on the elution order of stereoisomers. The interesting phenomenon of reversal of enantiomer/stereoisomer elution order function of the polysaccharide backbone (cellulose or amylose), type of derivative (carbamate or benzoate), nature, and position of the substituent(s) in the phenylcarbamate moiety (methyl or chloro) and the nature of the mobile phase was observed. For several of the analytes containing two chiral centers all four stereoisomers were resolved with at least one chiral selector/mobile phase combination.  相似文献   

15.
The enantiomeric pairs of cis and trans stereoisomers of cyclic β‐aminohydroxamic acids and their related cis and trans cyclic β‐amino acids containing two chiral centers were directly separated on four structurally related chiral stationary phases derived from quinine and quinidine modified with (R,R)‐ and (S,S)‐aminocyclohexanesulfonic acids. Applying these zwitterionic ion‐exchangers as chiral selectors, the effects of the composition of the bulk solvent, the acid and base additives, the structures of the analytes, and temperature on the enantioresolution were investigated. To study the effects of temperature and obtain thermodynamic parameters, experiments were carried out at constant mobile phase compositions in the temperature range 5–50°C. The differences in the changes in standard enthalpy Δ(ΔH°), entropy Δ(ΔS°), and free energy Δ(ΔG°) were calculated from the linear van't Hoff plots derived from the ln α versus 1/T curves in the studied temperature range. Results thus obtained indicated enthalpy‐driven separations in all cases. The sequence of elution of the enantiomers was determined and found to be reversed when ZWIX(–)™ was changed to ZWIX(+)™ or ZWIX(–A) to ZWIX(+A).  相似文献   

16.
The methods for the enantioseparation of m‐nisoldipine, a new 1,4‐dihydropyridine calcium ion antagonist, were developed. The elaborated methods of m‐nisoldipine enantiomers separation were successfully performed using an anionic CD–sulfobutyl ether‐β‐CD (SBE‐β‐CD) or carboxymethyl‐β‐CD as chiral selector. However, the results indicated that SBE‐β‐CD was a better chiral selector for enantioseparation of the neutral m‐nisoldipine. Furthermore, comparing the two SBE‐β‐CDs, the derivative with a higher degree of substitution (DS) of 7.0 induced better enantioresolution than the one with low DS (4.0). In addition, possible chiral recognition mechanisms of dihydropyridines were discussed.  相似文献   

17.
Cellulose tris(4-methylphenylcarbamate),amylose tris(3,5-dimethylphenylcarbamate) and amylose tris (phenylcarbamate) were prepared by the method reported by Okamoto and were coated onto an aminopropylated mesoporous spherical silica gel.These final products were used as chiral stationary phases of high performance liquid chromatography for the eighteen structurally related biphenyl compounds.The resolution was made using normal-phase methodology with a mobile phase consisting of n-hexane-alcohol(ethanol,1-propanol,2-propanol or 1-butanol).The effects of various aliphatic alcohols in the mobile phase were studied.The structural features of the solutes that influence their k′ were discussed.A dominant effects of trifluoroacetic acid on chiral separation of acidic solutes was noted.  相似文献   

18.
RP high‐performance liquid chromatographic methods were developed for the enantioseparation of eleven unusual β2‐homoamino acids. The underivatized analytes were separated on a chiral stationary phase containing (+)‐(18‐crown‐6)‐2,3,11,12‐tetracarboxylic acid as chiral selector. The effects of organic (alcoholic) and acidic modifiers, the mobile phase composition and temperature on the separation were investigated. The structures of the substituents in the α‐position of the analytes substantially influenced the retention and resolution. The elution sequence was determined in some cases: the S enantiomers eluted before the R enantiomers.  相似文献   

19.
The stereoisomers of five fluorinated cyclic β3‐amino acid derivatives and their nonfluorinated counterparts were separated on chiral stationary phases containing as chiral selectors cellulose tris‐(3,5‐dimethylphenyl carbamate), cellulose tris‐(3‐chloro‐4‐methylphenyl carbamate), cellulose tris‐(4‐methylbenzoate), cellulose tris‐(4‐chloro‐3‐methylphenyl carbamate), amylose tris‐(3,5‐dimethylphenyl carbamate) or amylose tris‐(5‐chloro‐2‐methylphenyl carbamate). The enantioseparations were carried out in normal‐phase mode with n‐hexane/alcohol/alkylamine mobile phases in the temperature range 5–40 °C. The effects of the mobile phase composition, the nature and concentration of the alcohol and alkylamine additives, the structures of the analytes and temperature on the separations were investigated. Thermodynamic parameters were calculated from plots of ln α vs. 1/T. The Δ(ΔH°) values ranged between ?5.0 and +1.6 kJ/mol, while Δ(ΔS°) varied between ?12.6 and +5.7 J/mol/K. The enantioseparation was enthalpically controlled, the retention factor and the separation factor decreasing with increasing temperature, but entropically controlled separation was also observed. The elution sequence was determined for all of the investigated analytes. Copyright © 2016 John Wiley & Sons, Ltd.  相似文献   

20.
The classical method for the preparation of immobilized polysaccharide‐based chiral stationary phases (CSPs) with a diisocyanate was improved. Cellulose or amylose was directly coated onto 3‐aminopropyl silica gel after it was dissolved in a mixture of N,N‐dimethylacetamide, LiCl, and pyridine, then immobilized onto silica gel with a diisocyanate, and finally allowed to react with an excess of corresponding isocyanate. Four polysaccharide derivatives, 3,5‐dimethylphenylcarbamate and 3,5‐dichlorophenylcarbamate of cellulose, and 3,5‐dimethylphenylcarbamate and 5‐chloro‐2‐methylphenylcarbamate of amylose, were immobilized onto silica gel utilizing this method. Compared with the classical diisocyanate method, the improved procedure avoided the derivatization and regeneration of 6‐hydroxyl groups of cellulose and amylose, and thus showed an advantage for simple and economical preparation. The relationships among the amount of diisocyanate used, immobilization efficiency, and enantioseparation on the cellulose‐based CSPs were investigated. Also, the solvent durability of the obtained CSPs was examined with eluents containing chloroform or THF. By utilizing these eluents, the chiral recognition abilities of the obtained CSPs for some of the tested racemates were improved.  相似文献   