首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
Ochratoxin A (OTA) is a mycotoxin produced by Aspergillus ochraceus and Penicillium verrucosum. It has been found and analysed in several foods and feeds. Owing to its toxicity and occurrence in food and feed, the European Community has issued directives and some countries have their own regulations for OTA contents in food, feed and beverages. This work describes a method for the determination of OTA in mulled and red wine. It is based on combined anion exchange/reversed-phase clean-up and was analysed by liquid chromatography coupled with tandem mass spectrometry (multiple reaction monitoring). The method was validated with natural contaminated and spiked wine samples with OTA contents from 1.34 to 3.48 g kg–1. Owing to its accuracy, good reproducibility and repeatability, this easy method is a good alternative to liquid chromatography–fluorescence detection methods.  相似文献   

2.
In this work, a reliable and selective procedure for the determination of thirteen fungicides in red and white wine samples is proposed. Solid-phase extraction (SPE) and liquid chromatography (LC) tandem mass spectrometry (MS/MS), based on a hybrid quadrupole time-of-flight (QTOF) system, were used as sample preparation and determination techniques, respectively. Extraction and purification of target analytes was carried out simultaneously by using a reversed-phase Oasis HLB (200mg) SPE cartridge combined with acetonitrile as elution solvent. Fungicides were determined operating the electrospray source in the positive ionization mode, with MS/MS conditions adjusted to obtain at least two intense product ions per compound, or registering two transitions per species when a single product was noticed. High selective MS/MS chromatograms were extracted using a mass window of 20 ppms for each product ion. Considering external calibration as quantification technique, the overall recoveries (accuracy) of the procedure ranged between 81% and 114% for red and white wine samples (10-20 mL), spiked at different concentrations between 5 and 100 ng mL(-1). Relative standard deviations of the above data stayed below 12% and the limits of quantification (LOQs) of the method, calculated for 10 mL of wine, varied between 0.1 ng mL(-1) for cyprodinil (CYP) and 0.7 ng mL(-1) for myclobutanil (MYC). The optimized method was applied to seventeen commercial wines produced in Spain and obtained from local supermarkets. Nine fungicides were determined, at levels above the LOQs of the method, in the above samples. The maximum concentrations and the highest occurrence frequencies corresponded to metalaxyl (MET) and iprovalicarb (IPR).  相似文献   

3.
A novel procedure for the determination of nine selected fungicides (metalaxyl-M, azoxystrobin, myclobutanil, flusilazole, penconazole, tebuconazole, propiconazole, diniconazole and difenoconazole) in wine samples is presented. Sample enrichment and purification is simultaneously performed using mixed-mode, anion exchange and reversed-phase, OASIS MAX solid-phase extraction (SPE) cartridges. Analytes were determined by liquid chromatography coupled to tandem mass spectrometry using atmospheric pressure electrospray ionization (LC-ESI-MS/MS). Parameters affecting the chromatographic determination and the extraction-purification processes were thoroughly investigated. Under optimized conditions, 10 mL of wine were firstly diluted 1:1 with ultrapure water and then passed through the mixed-mode SPE cartridge at a flow of ca. 5 mLmin(-1). After a washing step with 5 mL of an aqueous NH(4)OH solution (5%, w:v), analytes were recovered with just 1 mL of methanol and injected in the LC-MS/MS system without any additional purification. The selective extraction process avoided significant changes in the ionization efficiency for red and white wine extracts in comparison with pure standards in methanol. Performance of the method was good in terms of precision (RSDs<11%) and accuracy (absolute recoveries>72%, determined against pure standards in methanol) reporting method LOQs in the range of 0.01-0.79 ngmL(-1) for target compounds, which are far below the EU maxima residue levels (MRLs) for fungicides in vinification grapes and wine. Several commercial wines from different geographic areas in Spain were analyzed. In most samples, metalaxyl-M and azoxystrobin were found at concentrations up to several ngmL(-1).  相似文献   

4.
Desorption electrospray ionization (DESI) mass spectrometry appears to be a useful technique applicable in different areas (e.g. analysis of pharmaceuticals, identification of biologically active compounds in tissues, imaging mass spectrometry). Its modification termed desorption nano-electrospray (nano-DESI) was tested for analysis of anthocyanins. Acidifying of samples and acidic spray liquid (methanol:water = 75:25 with 0.2% HCOOH) were essential for obtaining good quality spectra. Profiles of main anthocyanins in wine samples, two vintages (2005 and 2007) of three cultivars (Alibernet, Neronet and Rubinet), were successfully acquired. They were in agreement with results of LC/MS experiments (anthocyanins isolated by solid phase extraction were separated by μ-HPLC with gradient elution and detected by ESI-MS). Nano-DESI-MS data also allowed to determine ratio of two cultivars (Neronet and Rubinet) in their mixture and to detect coloring of wine by tenturier or elderberry extract. Detection of main anthocyanins in slices of wine grape, chokeberries and elderberries or in a wine stain on cotton fabric is also presented.  相似文献   

5.
A method has been developed for the identification and quantitative determination of sulphated disaccharides derived from chondroitin sulphate (CS) and dermatan sulphate (DS) chains attached to proteoglycans (PGs). After digestion with Chondroitinase ABC, the pool of disaccharides can be directly separated by liquid chromatography on a porous graphitized carbon (PGC) column and identified by on-line electrospray mass spectrometry under negative ionization conditions. The relative intensities of the fragment ions obtained by MS/MS allow to distinguish the sulphate position. Calibration with standard disaccharides allows the quantification of the different isomers. The method showed good repeatability in terms of relative standard deviation (RSD < 2%) and linearity between 0.5 and 50 ng (total injected amount) for both 4- and 6-sulphated disaccharides. The limit of detection achieved in full scan mode was 0.1 ng. The methodology was applied to different types of biological samples obtained from patients suffering from chronic lung inflammation such as: lung tissue, bronchoalveolar lavage fluid (BALF), induced sputum and urine.  相似文献   

6.
This paper employs one chemometric technique to modify the noise spectrum of liquid chromatography–tandem mass spectrometry (LC–MS/MS) chromatogram between two consecutive wavelet-based low-pass filter procedures to improve the peak signal-to-noise (S/N) ratio enhancement. Although similar techniques of using other sets of low-pass procedures such as matched filters have been published, the procedures developed in this work are able to avoid peak broadening disadvantages inherent in matched filters. In addition, unlike Fourier transform-based low-pass filters, wavelet-based filters efficiently reject noises in the chromatograms directly in the time domain without distorting the original signals. In this work, the low-pass filtering procedures sequentially convolve the original chromatograms against each set of low pass filters to result in approximation coefficients, representing the low-frequency wavelets, of the first five resolution levels. The tedious trials of setting threshold values to properly shrink each wavelet are therefore no longer required. This noise modification technique is to multiply one wavelet-based low-pass filtered LC–MS/MS chromatogram with another artificial chromatogram added with thermal noises prior to the other wavelet-based low-pass filter. Because low-pass filter cannot eliminate frequency components below its cut-off frequency, more efficient peak S/N ratio improvement cannot be accomplished using consecutive low-pass filter procedures to process LC–MS/MS chromatograms. In contrast, when the low-pass filtered LC–MS/MS chromatogram is conditioned with the multiplication alteration prior to the other low-pass filter, much better ratio improvement is achieved. The noise frequency spectrum of low-pass filtered chromatogram, which originally contains frequency components below the filter cut-off frequency, is altered to span a broader range with multiplication operation. When the frequency range of this modified noise spectrum shifts toward the high frequency regimes, the other low-pass filter is able to provide better filtering efficiency to obtain higher peak S/N ratios. Real LC–MS/MS chromatograms, of which typically less than 6-fold peak S/N ratio improvement achieved with two consecutive wavelet-based low-pass filters remains the same S/N ratio improvement using one-step wavelet-based low-pass filter, are improved to accomplish much better ratio enhancement 25-folds to 40-folds typically when the noise frequency spectrum is modified between two low-pass filters. The linear standard curves using the filtered LC–MS/MS signals are validated. The filtered LC–MS/MS signals are also reproducible. The more accurate determinations of very low concentration samples (S/N ratio about 7–9) are obtained using the filtered signals than the determinations using the original signals.  相似文献   

7.
以强阳离子交换柱(SCX)为一维色谱柱,反相柱(RP)为二维色谱柱,采用在线捕集接口形式,通过10通阀连接一、二维色谱柱,构建了二维液相色谱分离系统。将该系统用于酶解猪血蛋白中对血管紧缩素Ⅰ转移酶(ACE)具有活性抑制作用的肽进行分离、鉴定,共检测出104个组分。收集一维馏分,离线注入LC—MS,鉴定出其中含有SAL、DKF、ESF、STVL及FESF5个小肽。  相似文献   

8.
The analysis of the signal transduction inhibitor imatinib in patient tumour tissue using LC and MS/MS is described. The anticancer agent is eluted over RP-C18 within 2 mm together with its internal standard STI571-d8. Calibration curves were prepared in red blood cells (RBC). For quantitative isolation of the RBC, measurement of sediment was applied. There were no indications of signal suppression by substances originating in the biological matrix. The limit of determination in tumour tissue was in the range of those recorded for RBC and plasma. The assay is selective and sensitive, with its robustness favouring the experimental application in clinical oncology and its routine use in animal experiments. The LOD was 4.5 ng per gram in tumour tissue.  相似文献   

9.
The polycondensation of guanidine hydrochloride and 2,2′-(ethylenedioxy)bis(ethylamine) leads to various types of oligomeric guanidines exhibiting a broad spectrum of biocidal activities. In the present work a reversed-phase high-performance liquid chromatographic method with a gradient consisting of aqueous 0.1% trifluoroacetic acid and acetonitrile as mobile phase has been developed to separate these oligoguanidines according to type and chain length. The combination with electrospray mass spectrometry allowed the identification of the various compounds. By this technique, some structures already suggested in the literature could be confirmed, and several additional oligoguanidines not yet reported could be identified. As a complementary technique, capillary zone electrophoresis was investigated. Best results were obtained with carrier electrolytes consisting of phosphoric acid in water/acetonitrile mixtures. Although the number of peaks that could be separated by the electrophoretic method was considerably lower than in case of the chromatographic method, capillary electrophoresis in combination with UV detection at 195 nm may still be a fast method suitable for quantitation of some of the major compounds and for monitoring the reaction rate during the polycondensation reaction.  相似文献   

10.
建立了亲水作用色谱-串联质谱同时测定液态奶中三聚氰酸和三聚氰胺的方法。液态奶样品经体积分数2.5%甲酸溶液提取、离心后乙腈稀释,亲水作用色谱柱分离,电喷雾串联四极杆质谱检测器检测,分别在负、正离子模式下测定三聚氰酸和三聚氰胺。三聚氰酸和三聚氰胺分别在0.5~100μg/L、0.1~50μg/L范围内线性关系良好。在0.25~15mg/kg、0.1~7.5mg/kg添加水平范围内,三聚氰酸平均回收率为84.5%~98.0%(RSD为2.1%~6.1%),三聚氰胺平均回收率为85.5%~88.9%(RSD为3.2~5.8%)。三聚氰酸、三聚氰胺定量限分别为0.25mg/kg、0.1mg/kg。  相似文献   

11.
The direct determination of double bond positions in unsaturated lipids using in-line ozonolysis-mass spectrometry (O3-MS) is described. In this experiment, ozone penetrates through the semi-permeable Teflon AF-2400 tubing containing a flow of a solution of fatty acid methyl esters (FAME). Unsaturated FAME are thus oxidized by the ozone and cleaved at the double bond positions. The ozonolysis products then flow directly into the atmospheric pressure photoionization (APPI) source of a mass spectrometer for analysis. Aldehyde products retaining the methyl ester group are indicative of the double bond positions in unsaturated FAME. For the first time, O3-MS is able to couple directly to high performance liquid chromatography (HPLC), making the double bond localization in lipid mixtures possible. The application of LC/O3-MS has been demonstrated for a fat sample from bovine adipose tissue. A total of 9 unsaturated FAME including 6 positional isomers were identified unambiguously, without comparison to standards. The in-line ozonolysis reaction apparatus is applicable to most mass spectrometers without instrumental modification; it is also directly compatible with various LC columns. The LC/O3-MS method described here is thus a practical, versatile and easy to use new approach to the direct determination of double bond positions in lipids, even in complex mixtures.  相似文献   

12.
In this work, the use of liquid chromatography coupled to electrospray time-of-flight mass spectrometry (LC-TOFMS) has been evaluated for the profiling of relatively low-molecular weight protein species in both genetically modified (GM) and non-GM maize. The proposed approach consisted of a straightforward sample fractionation with different water and ethanol-based buffer solutions followed by separation and detection of the protein species using liquid chromatography with a small particle size (1.8 μm) C(18) column and electrospray-time-of-flight mass spectrometry detection in the positive ionization mode. The fractionation of maize reference material containing different content of transgenic material (from 0 to 5% GM) led to five different fractions (albumins, globulins, zeins, zein-like glutelins, and glutelins), all of them containing different protein species (from 2 to 52 different species in each fraction). Some relevant differences in the quantity and types of protein species were observed in the different fractions of the reference material (with different GM contents) tested, thus revealing the potential use of the proposed approach for fast protein profiling and to detect tentative GMO markers in maize.  相似文献   

13.
A liquid chromatography (LC)/mass spectrometry method was developed for the determination of selected biogenic amines in various fish and other food samples. It is based on a precolumn derivatization of the amines with succinimidylferrocenyl propionate under formation of the respective amides and their reversed-phase liquid-chromatographic separation with subsequent electrospray ionization mass-spectrometric detection. Deuterated putescine, cadaverine, and histamine are added prior to the derivatization as internal standards that are coeluted, thus allowing excellent reproducibility of the analysis to be achieved. Depending on the analyte, the limits of detection were between 1.2 and 19.0 mg/kg, covering between 2 and 3 decades of linearity. The limit of detection and the linear range for histamine are suitable for the surveillance of the only defined European threshold for biogenic amines in fish samples. Compared with the established ortho-phthalaldehyde (OPA)/LC/fluorescence method, the newly developed method allows an unambiguous identification of the biogenic amines by their mass spectra in addition to only retention times, a fivefold acceleration of the separation, and independency from the sample matrix owing to the isotope-labeled internal standards. Various fish, calamari, and salami samples were successfully analyzed with the new method and validated with an independent OPA/LC/fluorescence method.  相似文献   

14.
Byproducts of arachidonic (AA) and docosahexaenoic acid (DHA) oxidation are highly relevant for the study of free radical associated conditions in the perinatal period. Plasma metabolites can provide the clinician with a snapshot of the oxidant status of patients before and after specific clinical interventions (e.g.: supplementation with oxygen). We describe a new andreliable ultra-performance liquid mass spectrometry method to determine F2-isoprostanes and other byproducts (isoprostanes, isofurans, neuroprostanes, neurofurans) in newborn serum samples. Cord blood samples were obtained from severely depressed newborn infants (Apgar score 1 min < 3; arterial cord pH < 7.00), and aliquoted for serum determination and stored at −80 °C. A UHPLC-MS/MS method was employed. It has a series of technical advantages: simple sample treatment; reduced sample volume (100 μL) which is essential for preterm neonates with low circulating blood volume, high throughput of sample analysis (96 samples in less than 24 h) and high selectivity for different isoprostanes isomers. Excellent sensitivity was achieved within limits of detection between 0.06 and 4.2 nmol L−1, which renders this method suitable to monitoranalyte concentration in newborn samples. The method's precision was satisfactory; with coefficients of variation around 5–12% (intra-day) and 7–17% (inter-day). The reliability of the described method was assessed by analysis of spiked serum samples obtaining recoveries between 70% and 120%. The proposed method has rendered suitable for serum determination for newborn babies at risk of oxygen free radical associated conditions.  相似文献   

15.
This work presents an advantageous analytical procedure for the accurate determination of free trans-resveratrol in red and white wines. The proposed method involves solid-phase extraction (SPE), acetylation of the analyte in aqueous media and further determination by gas chromatography (GC) with mass spectrometry detection (MS). The use of a mixed-mode SPE sorbent provides an improvement in the selectivity of the extraction step; moreover, the presence of several intense ions in the electron impact mass spectra of its acetyl derivative guarantees the unambiguous identification of trans-resveratrol. Considering a sample intake of 10 mL, the method provides a limit of quantification (LOQ) of 0.8 ng mL−1 and linear responses for concentrations up to 2.5 μg mL−1, referred to wine samples. The average recovery, estimated with samples fortified at different concentrations in the above range, was 99.6% and the inter-day precision stayed below 8%. Trans-resveratrol levels in the analyzed wines varied from 3.4 to 1810 ng mL−1. Cis-resveratrol was also found in all samples. In most cases, equal or higher responses were measured for this latter form than for the trans-isomer. The reduced form of resveratrol, dihydro-resveratrol, was systematically identified in red wines.  相似文献   

16.
17.
Yonkenafil is a promising drug for treatment of male erectile dysfunction. Previous studies showed that the piperazine‐N,N’‐deethylation metabolite, piperazine‐N‐deethylation metabolite, and piperazine‐N‐deethylation‐N,N’‐deethylation metabolite were the major metabolites of yonkenafil after extensive metabolism. We developed a sensitive and selective method for the simultaneous quantification of yonkenafil and its major metabolites using high‐throughput liquid chromatography with tandem mass spectrometry. Analytes and internal standard were extracted from a small quantity of plasma (50 μL) using liquid–liquid extraction with diethyl ether/dichloromethane (60:40, v/v), and the baseline separation was achieved on Zorbax SB‐C18 column using ammonia/water/methanol (0.2:20:80, v/v/v) as the mobile phase. The assay was performed with an electrospray positive ionization mass spectrometry through the multiple‐reaction monitoring mode within 2 min. Calibration curve of the method was linear within the range of 1.00–1000 ng/mL for all the analytes with the intra‐ and interday precisions of 4.0–5.2 and 4.0–5.3% for yonkenafil, 3.1–4.9 and 3.1–5.2% for the piperazine‐N,N’‐deethylation metabolite, 4.8–6.8 and 4.8–7.3% for the piperazine‐N‐deethylation metabolite, and 2.9–6.1 and 5.4–6.3% for the piperazine‐N‐deethylation‐N,N’‐deethylation metabolite, respectively. The recoveries were above 90% with low matrix effects. The validated assay was successfully applied to support a preclinical pharmacokinetic study in six rats using a single oral dose of yonkenafil (8 mg/kg).  相似文献   

18.
Gu Q  Shi X  Yin P  Gao P  Lu X  Xu G 《Analytica chimica acta》2008,609(2):192-200
Two simple, rapid and specific analytical methods for 13 catecholamines and their metabolites have been developed based on liquid chromatography tandem mass spectrometry in a multiple reaction monitoring mode. Tyrosine, dopamine, dihydroxyphenylalanine, epinephrine, norepinephrine, 3-methoxytyramine, normetanephrine, metanephrine and isoproterenol (internal standard) were separated on a Kromasil™ Cyano analytical column by a mobile phase consisting of 60% (v/v) acetonitrile and 40% (v/v) water adjusted with formic acid to pH 3.0, and detected by positive ionization electrospray tandem mass spectrometry. While vanillymandelic acid, 3,4-dihydroxymandelic acid, homovanillic acid, 3,4-dihydroxyphenylacetic acid, 4-hydroxy-3-methoxyphenylglycol and 5-hydroxy-2-indolecarboxylic acid (internal standard) were separated on a reversed-phase Shim-Pak VP-ODS column with the mobile phase of 60% (v/v) acetonitrile, and 40% (v/v) water adjusted with formic acid to pH 4.5 and detected in the negative ionization electrospray tandem mass spectrometry. The influence of various parameters such as column type and mobile phase composition on separation and sensitivity were investigated. The limits of detection were in the range of 0.5-20 ng mL−1. The mean recoveries determined from three different concentrations of each analyte were above 85.4%. The precision of the method calculated as relative standard deviation was lower than 5.3%. Deduced from the results of real sample analysis, adrenal gland synthesizes and stores the catecholamine hormones norepinephrine and epinephrine.  相似文献   

19.
Zhao C  Wu Z  Xue G  Wang J  Zhao Y  Xu Z  Lin D  Herbert G  Chang Y  Cai K  Xu G 《Journal of chromatography. A》2011,1218(23):3669-3674
Nanoflow liquid chromatography/mass spectrometry (nano-LC/MS) has attracted increasing interest in virtue of high sensitivity, low sample consumption, and minimal matrix effect. In this work a HPLC-Chip/quadrupole time-of-flight (Q-TOF) MS device with a new ultra-high capacity small molecule chip (UHC-Chip) which features a 500 nL enrichment column and a 150 mm × 75 μm analytical column, was evaluated with a drug mixture covering a wide range of polarities. Excellent chromatographic precision with 0.1-0.5% RSD for retention time and 1.7-9.0% RSD for peak area, low limit of detection, good chip-to-chip reproducibility and linearity were obtained by using this UHC-Chip. Compared with the standard HPLC-Chip with 40 nL trapping column, the UHC-Chip showed higher enrichment capability and hence gave a higher response in signal detection. Additionally, 4-30 times increase in sensitivity was obtained compared with conventional LC/MS, which indicated that UHC-Chip/MS was a valuable tool for the quantitative analysis of low level impurities and degradation products in pharmaceuticals. Moreover, satisfactory results obtained from trace drug analysis of serum samples further proved its practicality and potential for use in drug testing and development.  相似文献   

20.
Keto-enol tautomers of curcumin were confirmed by reversed-phase liquid chromatography(RPLC)/ hybrid quadrupole ion trap/time-of-flight mass spectrometry(QIT/TOFMS).Tautomers gave different MS/MS spectra in negative mode.Different mass spectra were also obtained by hydrogen/deuterium exchange LC/MS/MS in positive mode.Our results suggest that enol form is the major form in the solution(water/acetonitrile).  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号