首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 281 毫秒
1.
A simple, selective, sensitive, accurate, and precise method was developed for determination of metformin hydrochloride (MF) in human urine using RP-HPLC. The method depends upon using an octylsilyl (C8) 5 microm particle size column at ambient temperature with mobile phase consisting of 33 mM sodium dihydrogen phosphate containing 6.38 mM hexanesulfonic acid sodium salt and adjusted to apparent pH 3.0 with phosphoric acid-acetonitrile (93 + 7, v/v) at a flow rate of 1.5 mL/min. Quantitation was achieved with UV detection at 231 nm based on peak area with a linear calibration curve over the concentration range of 0.01-50 microg/mL. The proposed method was applied to the determination of the urinary excretion pattern of MF (the cumulative amounts excreted were calculated without pretreatment of the urine sample) and for determination of the dissolution pattern of MF tablets. The proposed method was completely validated according to the U.S. Food and Drug Administration guidelines.  相似文献   

2.
A high-performance liquid chromatographic method was optimized and validated for the determination of desacetyl nitazoxanide (tizoxanide), the main active metabolite of nitazoxanide in human plasma, urine and breast milk. The proposed method used a CN column with mobile phase consisting of acetonitrile-12mM ammonium acetate-diethylamine in the ratio of 30:70:0.1 (v/v/v) and buffered at pH 4.0 with acetic acid, with a flow rate of 1.5 mL/min. Quantitation was achieved with UV detection at 260 nm using nifuroxazide as internal standard. A simplified direct injection of urine samples without extraction in addition to the urinary excretion pattern were calculated using the proposed method. Also, the effectiveness of protein precipitation and a clean-up procedure were investigated for biological plasma and human breast milk samples. The validation study of the proposed method was successfully carried out in an assay range between 0.2 and 20 μg/mL.  相似文献   

3.
An HPLC method was developed and validated for the determination of ethacridine lactate in human urine. Solid-phase extraction cartridges were used to extract urine samples. Separation was carried out on a C(18) column maintained at 30 degrees C with methanol-0.05% sodium dodecylsulfonate (70:30, v/v, pH 3) as mobile phase at a flow rate of 1.0 mL/min. Detection was at UV 272 nm. The calibration curve was linear in the concentration range of 4-4000 ng/mL, with linear correlation coefficient r equal to 0.9998. The limit of detection for the assay was 1.1 ng/mL. The within-day accuracy ranged from 94.8 to 101.6% and precision from 2.3 to 5.4%. The between-day accuracy ranged from 96.8 to 102.6% and precision from 4.0 to 5.3%. The absolute recovery was 95.4-101.2%. Urine samples were stable for at least 15 days if stored in the dark at -20 degrees C. This simple and accurate method allows the sensitive determination of ethacridine lactate in human urine. It was successfully applied to assess the urine level of ethacridine lactate in women received intra-amniotic injection.  相似文献   

4.
Levofloxacin, pefloxacin, ciprofloxacin and moxifloxacin are four fluoroquinolones used in the treatment of serious bacterial infections. The antibacterial activity of fluoroquinolones is concentration dependent. Therefore, therapeutic drug monitoring in daily clinical practice is warranted to ensure the therapy's efficacy and prevent bacterial resistance. The purpose of the present study was to develop a method using high‐pressure liquid chromatography with an ultraviolet detector for simultaneous quantification of these four fluoroquinolones in human plasma. A 50 μL aliquot of plasma was precipitated by 200 μL of methanol using gatifloxacin as internal standard. The chromatographic separation was performed on a Kinetex XB‐C18 column using a mobile phase composed of a mixture of orthophosphoric acid 0.4% (v/v), acetonitrile and methanol at a flow rate of 1.2 mL/min. Dual UV wavelength mode was used, with levofloxacin and moxifloxacin monitored at 293 nm, and pefloxacin and ciprofloxacin monitored at 280 nm. The calibration was linear over the ranges of 0.125–25 mg/L for levofloxacin, 0.1–20mg/L for moxifloxacin and 0.05‐10 mg/L for both pefloxacin and ciprofloxacin. Inter‐ and intra‐day trueness and precision were <13% for all the compounds under study. The proposed method was simple, reliable, cost‐effective and suitable for therapeutic drug monitoring or pharmacokinetics studies.  相似文献   

5.
A high-performance liquid chromatography method with fluorescence detection (HPLC-FLD) for the determination of levofloxacin in human plasma is described. Neutralized with phosphate buffer (pH 7.0), the sample (0.1 mL) was extracted with dichlormethane (1 mL). After voltex-mixing and centrifuged at 3000g for 6 min at 4 degrees C, the upper aqueous layer was aspirated using a micro vacuum pump and the organic layer was directly transferred to a clean test tube without pipetting. The organic solvent was evaporated and the residues were reconstituted with the mobile phase. Levofloxacin and terazosin (internal standard, IS) were chromatographically separated on a C(18) column with a mobile phase containing phosphate buffer (pH 3.0, 10 mm), acetonitrile and triethylamine (76:24:0.076, v/v/v) at a flow rate of 1 mL/min. The analytes were detected using fluorescence detection at an excitation and emission wavelength of 295 and 440 nm, respectively. The linear range of the calibration curves was 0.0521-5.213 microg/mL for levofloxacin with a lower limit of quantitation (0.0521 microg/mL). The retention times of levofloxacin and terazosin were 2.5 and 3.1 min, respectively. Within- and between-run precision was less than 12 and 11%, respectively. Accuracy ranged from -6.3 to 4.5%. The recovery ranged from 86 to 89% at the concentrations of 0.0521, 0.5213 and 5.213 microg/mL. The present HPLC-FLD method is sensitive, efficient and reliable. The method described herein has been successfully used for the pharmacokinetic and bioequivalence studies of a levofloxacin formulation product after oral administration to healthy Chinese volunteers.  相似文献   

6.
A liquid chromatography (LC) method and an ultraviolet (UV) spectrophotometric method were developed and validated for quantitative determination of amlodipine in tablets and compounded capsules. The isocratic LC analyses were performed on an RP18 column using a mobile phase composed of 0.1% (v/v) ortho-phosphoric acid (pH 3.0) -acetonitrile (60 + 40, v/v) at a flow rate of 1.0 mL/min. The UV spectrophotometric method was performed at 238 nm. The analytical methods were validated according to International Conference on Harmonization Guidelines. The calibration graphs were linear [correlation coefficient (r) > 0.999] in the studied concentration range of 10-30 microg/mL for LC and 10-35 microg/mL for UV spectrophotometry. The relative standard deviation values for intraday and interday precision studies were less than 2%, and the accuracy was greater than 98% for both methods. The specificity of the LC method was proved using forced degradation. Statistical analyses showed no significant difference between the results obtained by the 2 methods. The proposed methods are precise and accurate and can be applied directly and easily to the oral pharmaceutical preparations of amlodipine.  相似文献   

7.
建立了超高效液相色谱-三重四极杆质谱高灵敏测定尿液和血浆中α-鹅膏毒肽、β-鹅膏毒肽和γ-鹅膏毒肽的方法。经过免疫亲和柱净化,尿液样品浓缩20倍、血浆样品浓缩10倍,以Kinetex Biphenyl色谱柱(100 mm×2.1 mm, 1.7 μm)作为分析柱,甲醇-0.005%(v/v)甲酸水溶液作为流动相进行梯度洗脱分离,电喷雾电离、负离子、多反应监测模式下检测,外标法定量。3种鹅膏毒肽的线性范围为0.1~200 ng/mL,相关系数(r)>0.999。尿液和血浆中3种鹅膏毒肽的基质效应和提取回收率分别为92%~108%和90%~103%,变异系数均小于13%。尿液中3种鹅膏毒肽的准确度为-9.4%~8.0%,重复性和中间精度分别为3.0%~14%和3.5%~18%,当取样量为2.00 mL时,方法的检出限均为0.002 ng/mL;血浆中3种鹅膏毒肽的准确度为-13%~8.0%,重复性和中间精度分别为3.9%~9.7%和5.5%~12%,当取样量为1.00 mL时,方法的检出限均为0.004 ng/mL。该法操作简单、灵敏、准确,已在中毒患者摄入野生蘑菇后138 h的尿液中检出0.0067 ng/mL α-鹅膏毒肽和0.0059 ng/mL β-鹅膏毒肽。该法已成功解决中毒患者尿液和血浆中超痕量鹅膏毒肽的检测难题,对于疑似中毒病人的早诊断、早治疗、降低死亡率都具有非常重要意义,也为今后开展此类毒素毒理作用及机体代谢规律的研究提供了可靠的技术支撑。  相似文献   

8.
A rapid and simple high-performance liquid chromatographic method with photodiode array detection was developed for the separation and the simultaneous determination of phenytoin and dextromethorphan in human urine. Analysis was performed in less than 4.5 min in isocratic mode on a reversed-phase C18 column (5 microm; 150 x 4.6 mm) using a mobile phase composed of acetonitrile-buffer phosphate 0.01 M (60:40, v/v) adjusted to pH 6.0, at 1 mL/min flow rate and UV absorbance at 210 nm. The elution order of analytes was dextromethorphan (DXM), Internal Standard (IS), and phenytoin (PHT). Calibration curves were linear in the 7.5-25 microg/mL range for PHT and in the 10-30 microg/mL range for DXM. Spike recoveries for urine samples prepared at three spiking levels ranged from 97.8 to 102.3% for PHT and from 94.8 to 100.4% for DXM. The detection limit (LOD) values ranged from 0.08 microg/mL for PHT to 0.5 microg/mL for DXM. The quantitation limit (LOQ) values ranged from 0.3 microg/mL for PHT to 1.6 microg/mL for DXM. The sample preparation method involves a rapid and simple procedure based on solid-phase extraction using a C18 reversed-phase column. Validation of the optimised method was carried out according to the ICH guidelines. The method developed in this study allows the reliable simultaneous analysis of PHT and DXM, drugs that were never quantified together in previously reported analytical methods. The described method has the advantage of being rapid and easy and it could be applied in therapeutic monitoring of these drugs in human urine of epileptic patients.  相似文献   

9.
A new, simple, precise and rapid high performance liquid chromatographic method was developed for the determination of meropenem in human serum, urine and pharmaceutical dosage forms. Chromatography was carried out on an LC(18) column using a mixture of 15 mM KH(2)PO(4):acetonitrile:methanol (84:12:4; v/v/v), adjusted to pH 2.8 with H(3)PO(4). The proposed method was conducted using a reversed-phase technique, UV monitoring at 307.6 nm and cefepime as an internal standard. The retention times were 5.98 and 7.47 min for cefepime and meropenem, respectively. The detector response was linear over the concentration range of 50-10,000 ng/mL. The detection limit of the procedure was found to be 22 ng/mL. The detection limit for meropenem in human plasma was 108.4 ng/mL and the corresponding value in human urine was 179.3 ng/mL. No interference from endogenous substances in human serum, urine and pharmaceutical preparation was observed. The proposed method is sufficiently sensitive for determination of the concentrations of meropenem and may have clinical application for its monitoring in patients receiving the drug.  相似文献   

10.
Quantitation of Zn‐DTPA (zinc diethylenetriamene pentaacetate, a metal chelate) in complex biological matrix is extremely challenging on account of its special physiochemical properties. This study aimed to develop a robust and specific liquid chromatography–tandem mass spectrometry (LC–MS/MS) method for determination of Zn‐DTPA in human plasma and urine. The purified samples were separated on Proteonavi (250 × 4.6 mm, 5 μm; Shiseido, Ginza, Tokyo, Japan) and a C18 guard column. The mobile phase consisted of methanol–2 mm ammonium formate (pH 6.3)–ammonia solution (50:50:0.015, v/v/v), flow rate 0.45 mL/min. The linear concentration ranges of the calibration curves for Zn‐DTPA were 1–100 μg/mL in plasma and 10–2000 μg/mL in urine. The intra‐ and inter‐day precisions for quality control (QC) samples were from 1.8 to 14.6% for Zn‐DTPA and the accuracies for QC samples were from −4.8 to 8.2%. This method was fully validated and successfully applied to the quantitation of Zn‐DTPA in plasma and urine samples of a healthy male volunteer after intravenous infusion administration of Zn‐DTPA. The result showed that the concentration of Zn‐DTPA in urine was about 20 times that in plasma, and Zn‐DTPA was completely (94.7%) excreted through urine in human.  相似文献   

11.
A reliable and sensitive HPLC method was developed for the quantitation of tadalafil transdermal permeation through human skin. An RP column with UV detection at 290 nm was used for chromatographic separation at ambient temperature. The mobile phase was acetonitrile-water containing 20 mM pH 7 phosphate buffer (35/65, v/v) with a flow rate of 1.0 mL/min. The LOQ achieved was 1 ng/mL, and the calibration curve showed good linearity over the concentration range of 5-2000 ng/mL for tadalafil, with a determination coefficient (R2) of 0.998. The RSD values of intraday and interday analyses were all within 7%. Parameters of validation proved the precision of the method; this validated method was applied for the determination of tadalafil in transdermal permeation and drug deposition in human skin studies.  相似文献   

12.
A specific method for the determination of 10 alpha-methoxy-9,10-dihydrolysergol, a nicergoline metabolite (metabolite 2), in urine is described. Metabolite 2 was well separated from the urine components on a reversed phase column, Hypersil ODS 5 microns, using an acetonitrile:pH 3.5 phosphate buffer (40:60, v/v) as the mobile phase at a flow rate of 1 mL/min. UV detection was set up at 220 nm. After addition of a known amount of lysergamide as the internal standard, the compounds were extracted from alkalysed urine on a pre-packed glass column (Extrelut 1) with dichloromethane. With 0.5 mL urine, concentrations down to 0.56 mumol/L could be determined.  相似文献   

13.
A method is described for the simultaneous determination of paracetamol, tizanidine, and diclofenac in mixtures. The method was based on HPLC separation of the three drugs followed by UV detection at 254 nm. The separation was carried out on a Hypersil ODS, C18 (250 x 4.6 mm id, 10 microm particle size) column using the mobile phase aqueous 0.2% ammonium carbonate-methanol (60 + 40, v/v) at a flow rate of 1 mL/min. The linear regression analysis data were used for the regression curve in the range of 170-10 000 ng/mL for paracetamol, 120-10 000 ng/mL for tizanidine, and 20-10 000 ng/mL for diclofenac. No chromatographic interference from tablet excipients was found. In order to check the selectivity of the proposed method, degradation studies were carried out using hydrolysis (acid, basic, and neutral), thermolysis, and oxidation. The developed method, after being validated in terms of precision, robustness, recovery, LOD, and LOQ, was successively applied to the analysis of pharmaceutical formulations and human serum.  相似文献   

14.
A high-performance liquid chromatography method with solid-phase extraction is introduced for the determination of geniposide in rat urine after oral administration of yin-zhi-ku decoction. Geniposide and an internal standard (paeoniflorin) are extracted from urine using Strata cartridges. Analysis of the extract is then performed on a reversed-phase C18 column using acetonitrile-water (14:86, v/v) as eluting solvent system. UV detection is set at 238 nm. The calibration curve for geniposide is linear (r = 0.9996) in the concentration range of 2.0-240 microg/mL. Both intra- and interday precision of the geniposide are determined, and their relative standard deviation does not exceed 10%. The validated method is successfully applied to determine geniposide from rat urine after oral administration of yin-zhi-ku decoction.  相似文献   

15.
A novel chemiluminescence method for the determination of levofloxacin is presented, which is based on the inhibitory effect of levofloxacin on the chemiluminescence reaction between luminol and myoglobin in a flow-injection system. The decrement of chemiluminescence intensity is linear with the logarithm of levofloxacin concentration over the range from 0.07 to 100.0 ng/mL (r 2 = 0.9994), with the detection limit of 0.02 ng/mL (3σ). At a flow rate of 2.0 mL/min, a complete analytical process could be performed within 0.5 min, including sampling and washing, with a relative standard deviation of less than 3.0% (n = 5). The proposed procedure was applied successfully to the determination of levofloxacin in pharmaceutical preparations, human urine and serum without any pretreatment procedure.  相似文献   

16.
A simple, sensitive and specific reversed-phase high-performance liquid chromatographic method with UV detection at 251 nm was developed for quantitation of buparvaquone (BPQ) in human and rabbit plasma. The method utilizes 250 microL of plasma and sample preparation involves protein precipitation followed by solid-phase extraction. The method was validated on a C18 column with mobile phase consisting of ammonium acetate buffer (0.02 m, pH 3.0) and acetonitrile in the ratio of 18:82 (v/v) at a flow rate of 1.1 mL/min. The calibration curves were linear (correlation coefficient>or=0.998) in the selected range. The method is specific and sensitive with limit of quantitation of 50 ng/mL for BPQ. The validated method was found to be accurate and precise in the working calibration range. Stability studies were carried out at different storage conditions and BPQ was found to be stable. Partial validation studies were carried out using rabbit plasma and intra- and inter-day precision and accuracy were within 7%. This method is simple, reliable and can be routinely used for preclinical pharmacokinetic studies for BPQ.  相似文献   

17.
A new, rapid, and sensitive liquid chromatography with tandem mass spectrometry method was developed for the determination of vitisin B and validated in rat plasma and urine using carbamazepine as an internal standard. The plasma (0.05 mL) or urine (0.2 mL) samples were extracted by liquid–liquid extraction with ethyl acetate and separated on an Eclipse Plus C18 column (100 × 4.6 mm, 3.5 μm) with a mobile phase consisting of acetonitrile and 0.1% formic acid water (60:40, v/v) at a flow rate of 0.7 mL/min. Detection and quantification were performed by mass spectrometry in selected reaction‐monitoring mode with positive electrospray ionization. The calibration curves were recovered over the concentration ranges of 10?5000 ng/mL (correlation coefficients, r≥0.9833) in plasma and 5?2500 ng/mL (r≥0.9977) in urine, respectively. All validation data, including the specificity, precision, accuracy, recovery, and stability, conformed to the acceptance requirements. No matrix effects were observed. The developed method was successfully applied to pharmacokinetic studies of vitisin B following intravenous administration of 0.5 and 1 mg/kg and intraperitoneal injection of 5, 10, and 25 mg/kg to rats. This is the first report on the pharmacokinetic properties of vitisin B. The results provide a meaningful basis to evaluate preclinical or clinical applications of vitisin B.  相似文献   

18.
Benzophenone-3 (BZ3), one of the compounds most commonly used as UV filter in cosmetic products, can be absorbed through the skin into the human body, since it can be found at trace levels in urine from users of cosmetic products that contain BZ3. Moreover, different undesirable effects have been attributed to this compound. Thus, sensitive analytical methods to monitor urinary excretion of this compound should be developed. This paper presents a selective and sensitive methodology for BZ3 determination at ultratrace levels in human urine samples. The methodology is based on a novel microextraction technique, known as single-drop microextraction (SDME). An ionic liquid (IL) has been used as extractant phase instead of an organic solvent. After the microextraction process, the extractant phase was injected into a liquid chromatography system. The variables of interest in the SDME process were optimized using a multivariate optimization approach. A Plackett-Burman design for screening and a circumscribed central composite design for optimizing the significant variables were applied. Ionic strength, extraction time, stirring speed, pH, ionic liquid type, drop volume and sample volume were the variables studied. The optimum experimental conditions found were: sodium chloride concentration, 13% (w/v); extraction time, 25 min; stirring speed, 900 rpm; pH, 2; ionic liquid type, 1-hexyl-3-methylimidazolium hexafluorophosphate ([C(6)MIM][PF(6)]); drop volume, 5 microL; and sample volume, 10 mL. The proposed method requires a standard addition calibration approach, and it has been successfully employed to determine free BZ3 in urine samples coming from human volunteers who applied a sunscreen cosmetic containing this UV filter. The limit of detection was in the order of 1.3 ng mL(-1) and repeatability of the method, expressed as relative standard deviation, was 6% (n=8).  相似文献   

19.
A simple and specific HPLC method with dual wavelength UV detection for the determination of ergosta‐4,6,8(14),22‐tetraen‐3‐one (ergone) in rat plasma was developed and proved to be efficient. The method used ergosterol as internal standard (IS). Following a single‐step protein precipitation, the analyte and IS were separated on an Inertsil ODS‐3 column with a mobile phase containing methanol–water (99:1, v/v) at a flow rate of 1 mL/min. The analytes were detected by using UV detection at wavelength of 350 (ergone) and 283 (IS) nm, respectively. The calibration curve was linear over the range of 0.1–2.0 µg/mL and the lower limit of quantification was 0.1 µg/mL. The intra‐day and inter‐day precision studies showed good reproducibility with RSD less than 8.5%. The intra‐day and inter‐day accuracy ranged from 95.6 to 104%. Mean extraction recovery was above 95% at the low, medium and high concentrations. The present HPLC‐UV method was simple and reliable. The method described herein had been successfully applied for the pharmacokinetic studies in male SD rats after administration of 20 mg/kg dose of solution of ergone. Copyright © 2010 John Wiley & Sons, Ltd.  相似文献   

20.
A sensitive HPLC method was developed and validated for the determination of sildenafil concentrations in rat plasma (200 μL) using a liquid–liquid extraction procedure and paroxetine as an internal standard. In order to eliminate interferences and improve the peak shape, a back‐extraction into an acidic solution was utilized. Chromatographic separation was achieved on a cyanopropyl bonded‐phase column with a mobile phase composed of 50 m m potassium dihydrogen phosphate buffer (pH 4.5) and acetonitrile (75:25, v/v), pumped at the flow rate of 1 mL/min. A UV detector was set at 230 nm. A calibration curve was constructed within a concentration range from 10 to 1500 ng/mL. The limit of detection was 5 ng/mL. The inter‐ and intra‐day precisions of the assay were in the ranges 2.91–7.33 and 2.61–6.18%, respectively, and the accuracies for inter‐ and intra‐day runs were within 0.14–3.92 and 0.44–2.96%, respectively. The recovery of sildenafil was 85.22 ± 4.54%. Tests confirmed the stability of sildenafil in plasma during three freeze–thaw cycles and during long‐term storage at ?20 and ?80°C for up to 2 months. The proposed method was successfully applied to a pharmacokinetic study in rats. Copyright © 2015 John Wiley & Sons, Ltd.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏