首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 93 毫秒
1.
The wave nature of light has been known for more than 100 years. However, it is still very difficult to directly sample an optical field transient on a time scale below the oscillation period. It has been naturally believed that the field oscillation can be detected only by using a reference pulse that has a shorter duration than the period of the oscillation. In this Letter, an experimental demonstration of a self‐referenced light wave measurement is shown. Frequency‐resolved optical gating capable of carrier‐envelope phase determination was used to measure the complete electric field evolution of a 21‐fs few‐cycle pulse without any reference pulses. A second harmonic generation frequency‐resolved optical gating spectrogram and an interferogram between second harmonic and self‐diffraction signals were simultaneously recorded. The phase‐controlled light waves of few‐cycle pulses were clearly observed by using this method.  相似文献   

2.
We review the state of the art of ultrashort-light-pulse measurement using frequency-resolved-optical-gating (FROG). Recent developments have extended the state of the art considerably. FROG devices for measuring the intensity and phase of ultrashort laser pulses have become so simple that almost no alignment is required. In addition, such devices not only operate single shot, but they also yield the two most important spatio-temporal distortions, spatial chirp and pulse-front tilt. With other FROG variations, it is now possible to measure more general ultrashort light pulses (i.e., pulses much more complex than common laser pulses), with time-bandwidth products as large as several thousand and as weak as a few hundred photons, and despite other difficulties such as random absolute phase and poor spatial coherence.  相似文献   

3.
Ultra‐short laser pulses with only a few optical cycles duration have gained increasing importance during the recent decade and are currently employed in many laboratories worldwide. In addition, modern laser technology nowadays can provide few‐cycle pulses at very high average power which advances established studies and opens exciting novel research opportunities. In this paper, the two complementary approaches for providing few‐cycle pulses at high average power, namely optical parametric amplification and nonlinear pulse compression, are reviewed and compared. In addition, their limitations and future scaling potential are discussed. Furthermore, selected applications particularly taking advantage of the high average power and high repetition rate are presented.  相似文献   

4.
One of the most advanced frontiers of ultrafast optics is the control of carrier‐envelope phase (CEP) ϕ of light pulses, which enables the generation of optical waveforms with reproducible electric field profile. Such control is important for pulses with few‐optical‐cycle duration, for which a CEP variation produces a strong change in the waveform, so that strongly nonlinear optical phenomena, such as multiphoton absorption, above‐threshold ionization and high‐harmonic generation become CEP‐dependent. In particular, CEP control is the prerequisite for the production of isolated attosecond pulses. Standard laser systems generate pulses that are CEP unstable; the CEP can be stabilized using either active or passive methods. Passive, all‐optical schemes rely on difference‐frequency generation (DFG) between two pulses sharing the same CEP: in this process the phases of the two pulses add up with opposite signs, leading to cancellation of the shot‐to‐shot CEP fluctuations. This paper presents an overview of passive CEP stabilization schemes, starting from the basic concepts and progressing to the details of the practical implementations of the idea. The passive approach allows the generation of CEP‐controlled few‐optical‐cycle pulses covering a very broad range of parameters in terms of carrier frequency (from visible to mid‐IR), energy (up to several mJs) and repetition rate (up to hundreds of kHz)  相似文献   

5.
The technical implementation of a multi‐MHz data acquisition scheme for laser–X‐ray pump–probe experiments with pulse limited temporal resolution (100 ps) is presented. Such techniques are very attractive to benefit from the high‐repetition rates of X‐ray pulses delivered from advanced synchrotron radiation sources. Exploiting a synchronized 3.9 MHz laser excitation source, experiments in 60‐bunch mode (7.8 MHz) at beamline P01 of the PETRA III storage ring are performed. Hereby molecular systems in liquid solutions are excited by the pulsed laser source and the total X‐ray fluorescence yield (TFY) from the sample is recorded using silicon avalanche photodiode detectors (APDs). The subsequent digitizer card samples the APD signal traces in 0.5 ns steps with 12‐bit resolution. These traces are then processed to deliver an integrated value for each recorded single X‐ray pulse intensity and sorted into bins according to whether the laser excited the sample or not. For each subgroup the recorded single‐shot values are averaged over ~107 pulses to deliver a mean TFY value with its standard error for each data point, e.g. at a given X‐ray probe energy. The sensitivity reaches down to the shot‐noise limit, and signal‐to‐noise ratios approaching 1000 are achievable in only a few seconds collection time per data point. The dynamic range covers 100 photons pulse?1 and is only technically limited by the utilized APD.  相似文献   

6.
A series of experiments were conducted in order to assess the robustness and accuracy of a recently developed digital image analysis technique (PDIA). This paper investigates the application of the PDIA technique to the sizing of relatively small fuel droplets of diameters in the range 5 to 30 μm produced by a pressure‐swirl atomizer. The measurement performance of the PDIA system has been assessed in terms of individual object diameters and also number and volume probability density functions of diameter in comparison to phase Doppler anemometry (PDA) data obtained under identical conditions. PDIA measurements revealed good agreement with spray data obtained by PDA at a measurement location 36 diameters downstream from the nozzle orifice with differences in the arithmetic mean diameter, D10 and volume mean diameter, D30 of approximately 5 and 3% respectively. The PDIA technique was shown to detect the presence of very large, predominantly non‐spherical droplets whose diameters were in excess of 100 μm. These droplets, although few in number constitute a significant proportion of the total spray volume and would have otherwise been either erroneously measured or have passed through the probe volume undetected using PDA due to non‐sphericity. Smaller objects may also be measured correctly by both methods although sensitivity to signal‐to‐noise ratio, for both methods can generate spurious and contradictory errors.  相似文献   

7.
Sperm whale clicks are characterized by a multi-pulsed structure. The time lag between consecutive pulses, i.e., the inter-pulse interval (IPI), is related to the size of the sound production organ such that its measurement provides a means to acoustically estimate the size of individual whales. Due to off-axis effects the identification of pulses is, however, not always straightforward, and automatic measurement methods provide not only more objective estimation, but may also facilitate IPI estimation in cases where single click measurements are ambiguous. In particular, averaging measurements over a time series of clicks from the same whale could enhance the discrimination of time invariant pulses. The authors developed two automatic methods of automatic IPI measurement based on waveform and autocorrelation averaging and compared their accuracy and consistency with other previously used methods. Manual measurement by an experienced operator provided the most self-consistent estimates. The autocorrelation averaging technique had the best overall performance of the automated methods achieving a very similar performance to manual measurement. On some recordings cepstrum averaging methods converged when autocorrelation did not. Therefore, applying both of these automated methods and choosing the best of the two are recommended.  相似文献   

8.
We present a double-pass non-collinear optical parametric amplifier (NOPA) that delivers 4-fs visible–near-infrared pulses. The paper discusses geometrical and temporal properties of the NOPA configuration, which allow us to broaden the gain band of simultaneous parametric amplification in excess of 250 THz. The key elements of the bandwidth enhancement include (i) the use of a broadband second-harmonic pump, (ii) optimization of the incidence angle of all monochromatic spectral components of the pump in order to produce a favorable offset of the corresponding phase-matching curves, and (iii) selection of the chirp rate and time delay between the stretched pump and seed pulses. We next devise a two-stage compressor that incorporates a flexible mirror for adaptive pulse shaping and develop a simple and trustworthy feedback loop based on a one-dimensional spectral measurement. Our rapid numerical algorithm for adaptive control of the flexible membrane is found superior to more complex search routines that are less resistant to the fluctuations of the laser intensity. The automated optimization procedure results in the generation of two-cycle pulses with a carrier wavelength at ∼600 nm. The absence of deep modulation on the parametrically amplified spectrum in combination with the adaptive phase correction lead to a high quality of the temporal profile and allow concentrating 90% of the pulse energy within only a 7.5-fs time window. Received: 8 April 2002 / Revised version: 26 June 2002 / Published online: 25 September 2002 RID="*" ID="*"Present address: Institut für Photonik, Technische Universit?t Wien, Gusshausstrasse 27, 1040 Vienna, Austria RID="**" ID="**"Corresponding author. Fax: +81-3/5841-4165, E-mail: kobayashi@phys.s.u-tokyo.ac.jp  相似文献   

9.
This article describes a methodology for the analysis of minor and trace elements in petroleum cokes by wavelength‐dispersive X‐ray fluorescence (WD‐XRF) spectrometry. The methodology was developed in order to have a rapid and reliable control method of these elements, because they determine coke end uses. There are a number of standard methods of chemical analysis by WD‐XRF or inductively coupled plasma atomic emission spectrometry (ICP‐OES) techniques. However, the standards that use WD‐XRF measurement give detection limits (LD) above 10 mg·kg?1 and only analyse a few elements of interest, whereas the ICP‐OES method requires extensive sample handling and long sample preparation times, with the ensuing errors. In order to improve the method described in the standard ASTM D6376 and reach the LD and quantification limits (LQ) required, the different stages of the process, ranging from sample preparation to measurement conditions: analytical line, detector, crystal, tube power, use of primary beam filters, and measurement time, were optimised. The samples were prepared in the form of pressed pellets, under conditions of high cleanliness of the mills, crushers, presses, and dies, and of the laboratory itself. The following reference materials were used in measurement calibration and validation: SRM 1632c, SRM 2718, SRM 2719, SRM 2685b, AR 2771, AR 2772, SARM 18, SARM 19, and CLB‐1. In addition, a series of materials were analysed by WD‐XRF and ICP‐OES, and the results were compared. The developed methodology, which uses WD‐XRF, is rapid and accurate, and very low LD and measurement uncertainties were obtained for the following elements: Al, Ba, Ca, Cr, Cu, Fe, Ge, K, Mg, Mn, Mo, Na, Ni, P, Pb, S, Sb, Se, Si, Sn, Sr, Ti, V, and Zn. Copyright © 2010 John Wiley & Sons, Ltd.  相似文献   

10.
Melamine, a nitrogen‐rich chemical, has recently caused enormous economic losses to the food industry due to the cases of milk products adulterated by melamine. This has led to an urgent need of rapid and reliable methods for detection of melamine in food. In this study, surface‐enhanced Raman scattering (SERS) spectroscopy was used to detect melamine in liquid milk. The sample preparation with liquid milk is very easy; it has to be only diluted with double‐distilled water followed by centrifugation. By using a silver colloid, at least a 105‐fold enhancement of the Raman signal was achieved for the measurement of melamine. The limit of detection by this method was 0.01 µg ml−1 for melamine standard samples. Based on the intensity of the Raman vibrational bands normalised to that of the band at 928 cm−1 (CH2), an external standard method was employed for quantitative analysis. The linear regression square (R2) of the curve was 0.9998; the limit of quantitation using this approach was 0.5 µg ml−1 of melamine in liquid milk; the relative standard deviation was ≤10%; and recoveries were from 93 to 109%. The test results for SERS were very precise and as good as those obtained by liquid chromatography/tandem mass spectrometry. The method was simple, fast(only needs about 3 min), cost effective, and sensitive for the detection of melamine in liquid milk samples. Therefore, it is more suitable for the field detection of melamine in liquid milk. Copyright © 2010 John Wiley & Sons, Ltd.  相似文献   

11.
A protocol is proposed to realize one‐step implementation of the N‐qubit nonadiabatic holonomic quantum gates with superconducting qubits. The inverse Hamiltonian engineering is applied in designing microwave pulses to drive superconducting qubits. By combining curve fitting, the wave shapes of the designed pulses can be described by simple functions, which are not hard to realize in experiments. To demonstrate the effectiveness of the protocol, a three‐qubit holonomic controlled π‐phase gate is taken as an example in numerical simulations. The results show that the protocol holds robustness against noise and decoherence. Therefore, the protocol may provide an alternative approach for implementing N‐qubit nonadiabatic holonomic quantum gates.  相似文献   

12.
Developments in continuous and pulsed laser‐heating techniques, and finite‐element calculations for diamond anvil cell experiments are reported. The methods involve the use of time‐resolved (5 ns gated) incandescent light temperature measurements to determine the time dependence of heat fluxes, while near‐IR incandescent light temperature measurements allow temperature measurements to as low as 500 K. Further optimization of timing in pulsed laser heating together with sample engineering will provide additional improvements in data collection in very high PT experiments.  相似文献   

13.
We consider the realization of a quantum computer in a chain of nuclear spins coupled by an Ising interaction. Quantum algorithms can be performed with the help of appropriate radio-frequency pulses. In addition to the standard nearest-neighbor Ising coupling, we also allow for a second neighbor coupling. It is shown, how to apply the 2π k method in this more general setting, where the additional coupling eventually allows to save a few pulses. We illustrate our results with two numerical simulations: the Shor prime factorization of the number 4 and the teleportation of a qubit along a chain of 3 qubits. In both cases, the optimal Rabi frequency (to suppress non-resonant effects) depends primarily on the strength of the second neighbor interaction.  相似文献   

14.
We address the problem of characterization of light pulses that propagate in long-haul high-bit-rate optical communication systems, under strongly perturbed conditions. We show that the conventional technique for characterization of the phase and intensity profile of such pulses becomes qualitatively inconsistent when the pulse’s profile is asymmetrically distorted with respect to its center-of-mass. We resolve these inconsistencies by partially reformulating the conventional technique by means of appropriate pulse parameters, which we call upgraded parameters, which allow a fair characterization of the intensity and phase of all types of light pulses, including those which are asymmetrically distorted. We illustrate the effectiveness of the upgraded parameters by applying them to a meticulous characterization of light pulses in a dispersion-managed optical fiber system in which third-order dispersion is acting as a strong perturbation.  相似文献   

15.
A new setup and commissioning of transient X‐ray absorption spectroscopy are described, based on the high‐repetition‐rate laser pump/X‐ray probe method, at the 1W2B wiggler beamline at the Beijing Synchrotron Radiation Facility. A high‐repetition‐rate and high‐power laser is incorporated into the setup with in‐house‐built avalanche photodiodes as detectors. A simple acquisition scheme was applied to obtain laser‐on and laser‐off signals simultaneously. The capability of picosecond transient X‐ray absorption spectroscopy measurement was demonstrated for a photo‐induced spin‐crossover iron complex in 6 mM solution with 155 kHz repetition rate.  相似文献   

16.
Liquid chromatography and mass spectrometry were time‐consuming and expensive as the main methods for the drug analysis at present, and the samples must be pretreated. The Raman spectroscopy measurement methods were fast and simple, so the Raman spectroscopy methods for the drug analysis were explored in this paper. An optical fiber nano‐probe coated with gold nanoparticles was fabricated and used with surface‐enhanced Raman spectroscopy (SERS) to measure levofloxacin lactate. The resulting SERS spectra of levofloxacin lactate in mouse blood that was detected by the optical fiber nano‐probe clearly showed the characteristic wave numbers of levofloxacin lactate, indicating that optical fiber nano‐probes can be used with spectral techniques to analyze drugs in vitro or potentially even in vivo. Copyright © 2015 John Wiley & Sons, Ltd.  相似文献   

17.
The possibility of using a parabolic refractive lens with initial X‐ray free‐electron laser (XFEL) pulses, i.e. without a monochromator, is analysed. It is assumed that the measurement time is longer than 0.3 fs, which is the time duration of a coherent pulse (spike). In this case one has to calculate the propagation of a monochromatic wave and then perform an integration of the intensity over the radiation spectrum. Here a general algorithm for calculating the propagation of time‐dependent radiation in free space and through various objects is presented. Analytical formulae are derived describing the properties of the monochromatic beam focused by a system of one and two lenses. Computer simulations show that the European XFEL pulses can be focused with maximal efficiency, i.e. as for a monochromatic wave. This occurs even for nanofocusing lenses.  相似文献   

18.
马晓璐  李培丽  郭海莉  张一  朱天阳  曹凤娇 《物理学报》2014,63(24):240601-240601
利用单模光纤中的光弹效应和交叉相位调制(XPM)效应,提出了一种频率分辨光学开关法测量超短脉冲的新方案.在本方案中,单模光纤的前一部分产生可变延迟,后一部分作为非线性介质产生非线性效应.该方案只需一根单模光纤,无须复杂的光路校准,结构简单,损耗低;光纤中的XPM效应易发生,无须相位匹配.对提出的方案进行了数值模拟,采用基于矩阵的主元素广义投影算法,恢复出待测脉冲的幅度和相位信息,并研究了光纤长度和待测超短脉冲的脉冲宽度对测量结果的影响.结果表明:测量准确度随着光纤长度的增加而提高,选取长度为2 km的光纤,就可以实现对超短脉冲的准确测量;本文方案适用于脉冲宽度不小于80 fs的超短光脉冲的测量.  相似文献   

19.
This paper describes the generation of small water droplets in the size range down to a few microns. Commercially available inkjet printing devices are not suitable for producing such droplets since they produce satellite droplets. Furthermore, standard drop‐on‐demand devices are normally restricted to the generation of droplets with the same size as the orifice diameter. Using a new and more sophisticated computer‐based signal generation system, smaller‐sized droplets can be generated from the same orifice. A key feature of the design is the generation of freely definable pulses. This enables the generation of acoustic modes within the fluid of the droplet generator, which leads to the generation of droplets without satellites. Only very few pulse forms enable the generation of suitable acoustic modes. Therefore, it is necessary to look for the specific pulse corresponding to the chosen droplet generator. Flexible pulse form generation appears to be more suitable than simple pulse forms for the generation of such droplets.  相似文献   

20.
The investigation of ultrafast dynamics, taking place on the few to sub‐picosecond time scale, is today a very active research area pursued in a variety of scientific domains. With the recent advent of X‐ray free‐electron lasers (XFELs), providing very intense X‐ray pulses of duration as short as a few femtoseconds, this research field has gained further momentum. As a consequence, the demand for access strongly exceeds the capacity of the very few XFEL facilities existing worldwide. This situation motivates the development of alternative sub‐picosecond pulsed X‐ray sources among which femtoslicing facilities at synchrotron radiation storage rings are standing out due to their tunability over an extended photon energy range and their high stability. Following the success of the femtoslicing installations at ALS, BESSY‐II, SLS and UVSOR, SOLEIL decided to implement a femtoslicing facility. Several challenges were faced, including operation at the highest electron beam energy ever, and achievement of slice separation exclusively with the natural dispersion function of the storage ring. SOLEIL's setup also enables, for the first time, delivering sub‐picosecond pulses simultaneously to several beamlines. This last feature enlarges the experimental capabilities of the facility, which covers the soft and hard X‐ray photon energy range. In this paper, the commissioning of this original femtoslicing facility is reported. Furthermore, it is shown that the slicing‐induced THz signal can be used to derive a quantitative estimate for the degree of energy exchange between the femtosecond infrared laser pulse and the circulating electron bunch.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号