1.
In order to fulfill a need to measure water in crude oils containing materials that interfere with the measurement of water by the Karl Fischer method, by reacting with iodine or iodide, a coulometric method has been developed and validated using 0.1 mol L(-1) Sodium thiosulfate as a calibrant. These interfering substances were measured in water-mass-equivalents, which were expressed as the mass of water that reacts with an equal mass of iodine in the Karl Fischer method. The SO(2)-free reagent that has been modified reacts quantitatively with sodium thiosulfate, cysteine and ascorbic acid but does not react with vinyl acetate. The level of interfering substances was measured in five transformer oils (including Reference Materials RM 8506 and RM 8507), a high and a low sulfur crude oil (Standard Reference Materials SRM 2721 and SRM 2722 respectively), a white oil, a high-vacuum oil and a high-viscosity base-stock oil. One oil contained less than 10 mg kg(-1) (water-mass-equivalents of interfering substances in oil) and two oils (RM 8507 and Drakeol 35) contained no measurable amount of interfering material (<0.2 mg kg(-1)). SRM 2271, a sour crude oil contained 834 mg kg(-1) (standard deviation (SD)=25 mg kg(-1)) (water-mass-equivalents of interfering substances in oil). Approximately 20% of this material was volatile and an additional 20% appeared to undergo some degradation (possibly oxidation) once the oil was exposed to air. These results indicate that this is a general method for measuring substances in oils that react with iodine and that it is capable of measuring in a variety of oils, using commercial instrumentation, interfering substances that inflate water measurements.  相似文献   

2.
A method has been developed for analysis of the highly potent polycyclic aromatic hydrocarbon (PAH) carcinogens dibenzo(a,l)pyrene, dibenzo(a,h)pyrene, and dibenzo(a,i)pyrene (molecular weight 302) present in small amounts in diesel and air particulate material. The method can also be used for analysis of the PAH benzo(a)pyrene, coronene, and perylene, for which reference and certified values are available for the standard reference materials used for validation of the method—SRM 1649a (urban dust) and SRM 2975 (diesel particulate matter). The only NIST values that have been published for these dibenzopyrene isomers in the analyzed SRM are reference values for dibenzo(a,i)pyrene and dibenzo(a,h)pyrene in SRM 1649a. The concentrations determined in the SRM were in good agreement with reported NIST-certified and reference values and other concentrations reported in the literature. Standard reference material 1650 (diesel particulate matter) was also analyzed. The method could not, however, be validated using this material because certification of SRM 1650 had expired. The method is based on ultrasonically assisted extraction of the particulate material, then silica SPE pre-separation and isolation, and, separation and detection by hyphenated LC–GC–MS. The method is relatively rapid and requires only approximately 1–5 mg SRM particulate material to identify and quantify the analytes. Low extraction recoveries for the analytes, in particular the dibenzopyrenes, when extracting diesel SRM 2975 and 1650 resulted, however, in the dibenzopyrenes being present in amounts near their limits of quantifications in these samples. The method’s limit of quantification (LOQ), based on analyses of SRM 1649a, is in the range 10–77 pg. By use of this method more than 25 potential PAH isomers with a molecular weight of 302 could be separated.  相似文献   

3.
Low lead levels in the femurs of mice fed with a lead-depleted diet have been determined by use of electrothermal atomic absorption spectrometry with Zeeman-effect background correction. The method is based on the use of Mg(NO3)2/Pd as matrix modifier which enables significant reduction of the spectral interferences prevalent if chemical modifiers based on NH4H2PO4 with either Ca or Mg are used for samples rich in Ca3(PO4)2 matrix. The method was developed and validated by use of the NIST standard reference material 1486 bone. Bones were decomposed in a pressurized microwave-heated system using 70% nitric acid. Forty-three mice femurs, with a mass of 74.62 +/- 12.54 mg, were dissolved in concentrated nitric acid. The lead results found in SRM 1486 (1.25 +/- 0.15 microg g(-1), n = 9) were in good agreement with the certificate (1.335 +/- 0.014 microg g(-1)). Recoveries of 200 ng lead added to the SRM before or after digestion were 99.0 +/- 1.4% and 98.5 +/- 1.6%, respectively. The lead detection limit in bone samples is 0.06 microg g(-1) dry mass. This method is, therefore, suitable for the determination of very low lead levels (0.06-0.20 microg Pb kg(-1) bone) in the femurs of mice fed a diet with lead level of < 20 microg kg(-1).  相似文献   

4.
Gas chromatography/mass spectrometry (GC/MS) with negative ion chemical ionization (NICI) detection was utilized for quantitative determination of nitrated polycyclic aromatic hydrocarbons (nitro-PAHs) in diesel particulate-related standard reference materials (SRMs). Prior to GC/MS analysis, isolation of the nitro-PAHs from the complex diesel particulate extract was accomplished using solid phase extraction (SPE) and normal-phase liquid chromatographic (LC) fractionation using an amino/cyano stationary phase. Concentrations of eight to ten mononitro-PAHs and three dinitropyrenes were determined in three diesel particulate-related SRMs: SRM 1650a Diesel Particulate Matter, SRM 1975 Diesel Particulate Extract, and SRM 2975 Diesel Particulate Matter (Industrial Forklift). The results from GC/MS NICI using two different columns (5% phenyl methylpolysiloxane and 50% phenyl methylpolysiloxane) were compared to each other and to results from two other laboratories for selected nitro-PAHs. 1-Nitropyrene was the most abundant nitro-PAHs in each of the diesel particulate SRMs (19.8+/-1.1 micro g g(-1) particle in SRM 1650a and 33.1+/-0.6 micro g g(-1) particle in SRM 2975). Three dinitropyrene isomers were measured in SRM 1975 at 0.5-1.4 micro g g(-1) extract and in SRM 2975 at 1-3 micro g g(-1) particle.  相似文献   

5.
The measurement of the amount of water in oils is of significant economic importance to the industrial community, particularly to the electric power and crude oil industries. The amount of water in transformer oils is critical to their normal function and the amount of water in crude oils affects the cost of the crude oil at the well head, the pipeline, and the refinery. Water in oil Certified Reference Materials (CRM) are essential for the accurate calibration of instruments that are used by these industries. Three NIST Standard Reference Materials (SRMs) have been prepared for this purpose. The water in these oils has been measured by both coulometric and volumetric Karl Fischer methods. The compounds (such as sulfur compounds) that interfere with the Karl Fischer reaction (interfering substances) and inflate the values for water by also reacting with iodine have been measured coulometrically. The measured water content of Reference Material (RM) 8506a Transformer Oil is 12.1+/-1.9 mg kg(-1) (plus an additional 6.2+/-0.9 mg kg(-1) of interfering substances). The measured water content of SRM 2722 Sweet Crude Oil, is 99+/-6 mg kg(-1) (plus an additional 5+/-2 mg kg(-1) of interfering substances). The measured water content of SRM 2721 Sour Crude Oil, is 134+/-18 mg kg(-1) plus an additional 807+/-43 mg kg(-1) of interfering substances. Interlaboratory studies conducted with these oil samples (using SRM 2890, water saturated 1-octanol, as a calibrant) are reported. Some of the possible sources of bias in these measurements were identified, These include: improperly calibrated instruments, inability to measure the calibrant accurately, Karl Fischer reagent selection, and volatilization of the interfering substances in SRM 2721.  相似文献   

6.
Laser ablation-inductively coupled plasma-mass spectrometry (LA-ICP-MS) was used to determine the Pb/Ca ratios in the enamel of deciduous incisors, a biomarker of in utero Pb exposure, using pelletized bone certified reference materials (CRMs) as calibrants. The detection limit for Pb by LA-ICP-MS was 11 microg kg(-1) demonstrating an adequate sensitivity for Pb in the teeth of unexposed individuals (0.1-10 mg kg(-1)). The precision for the Pb/Ca ratios in NIST SRM 1486 Bone Meal was 3.4%. The correlation between Pb/Ca ratios obtained by LA-ICP-MS and those obtained by a digestion method was highly significant. We found one point calibration by a CRM was applicable for the quantification of Pb in tooth enamel. This method will be valuable for the assessment of in utero Pb exposure levels.  相似文献   

7.
Toxaphene is a complex technical mixture that has been found ubiquitously in the environment but has caused issues for analysis, especially of individual congeners. This paper reports the elution order of 26 major toxaphene congeners on three gas chromatographic columns. The three different stationary phases generally had similar elution orders for the toxaphene congeners, but fewer co-elutions occurred on a low-bleed, low-polarity column. These congeners (except for two that co-eluted and were not added to the calibration mixture) were examined in air particulate matter standard reference materials (SRMs), 1648a, 1649a, and 1649b as well as SRM 3067 toxaphene in methanol for assignment of reference values. SRM 3067 had mass fractions an order of magnitude greater than the air particulate SRMs, which ranged from 0.568 ± 0.018 ng g−1 dry mass (B9-2006 in SRM 1648a) to 12.9 ± 0.20 ng g−1 dry mass (B9-715 (P 58) in SRM 1649a). The three air particulate SRMs all had different mass fractions and proportions of congeners relative to the sum of the toxaphene congeners. SRM 3067 may be useful as a technical mixture toxaphene congener calibrant. SRMs 1648a and 1649b will serve as reference materials for the analysis of 21 (three congeners were not included due to values below the detection limit or a potential polychlorinated biphenyl co-elution) toxaphene congeners in atmospheric particulate samples.  相似文献   

8.
1-Nitropyrene (1-NP) is enriched in diesel exhaust particulate matter (DPM) relative to other sources of particulate matter (PM), and has been proposed as a marker for DPM. However, in ambient air, 1-NP concentrations are typically in the low pg/m(3) range. Therefore, collection of large volume air samples coupled with extensive sample clean-up procedures has been required to achieve adequate detection limits to measure 1-NP in ambient samples. We report here an improved LC-MS/MS method suitable for the detection and quantification of 1-NP in low volume ambient PM samples. The method involves ultrasonic extraction of ambient PM in organic solvent, concentration of the sample under reduced pressure, and two-dimensional HPLC analysis of the extract. 1-NP is isolated on the first HPLC column, then converted to 1-aminopyrene (1-AP) via online reduction in a column packed with a Pt/Rh catalyst. The 1-AP containing fraction from the first column is refocused on a trapping column, then eluted through a second HPLC column prior to MS/MS detection. Deuterated (d(9)) 1-NP (1-dNP) is added to each sample prior to extraction as an internal standard for quantification of 1-NP. The accuracy and precision of the assay, as applied to ambient particulate standard reference materials are 110+/-5.7% for SRM 1650b, 116+/-7.1% for SRM 2975, 108+/-5.8% for SRM 1649a, and 53+/-9.2% for SRM 1648. The analytical limit of detection was 152 fg on column, and analytical limit of quantitation 221 fg on column. To our knowledge, the sensitivity of this method is comparable with GC-NICI-MS methods while having the advantage of considerably less extensive sample preparation. This method is an approximately 10-fold improvement in sensitivity over HPLC methods utilizing fluorescence and/or chemiluminescence detection.  相似文献   

9.
A capillary electrophoresis (CE) method has been developed and validated for the determination of the distribution of metals in particulate matter after three-stage sequential extraction. Fe(II), Zn(II), Cu(II), Mn(II), and Cd(II) ions were separated using a background electrolyte consisting of 200 mmol L(-1) ammonium acetate (pH 5.5), 0.5 mmol L(-1) 1,10-phenanthroline, 10 mmol L(-1) hydroxylamine hydrochloride, and 20% acetone. The method was validated with respect to specificity, linearity, detection limits, precision, and accuracy. Detection limits are at sub-microg L(-1) levels (tens of microg g(-1) of particulate matter) using pressure injection. The analytical procedure was checked by analyzing a standard reference material, NIST SRM 1648 Urban Particulate Matter.  相似文献   

10.
A comparison between open microwave digestion and digestion by conventional heating was carried out for the determination of Cd, Cr, Cu, and Pb in two algae matrices using transverse heated electrothermal atomic absorption spectrometry (ETAAS). A SRM GBW 08504 cabbage was also analysed. These matrices were digested with HNO3, using a quartz vessel for microwave digestion and PFA vessel for digestion by conventional heating. Cd, Cu and Cr were determined without any modifier, while magnesium nitrate and ammonium phosphate mixed modifier was used for Pb. Results obtained by both the procedures were in good agreement with each other at 95% confidence level, and for SRM GBW 08504 cabbage the values agree well with the certified values. The limits of detection obtained were 0.0004, 0.060, 0.065 and 0.054 mg/kg for Cd, Cr, Cu, and Pb, respectively, using the microwave digestion process. The RSD for Cd was 10-15% and for the other elements 5-10%.  相似文献   

11.
Both (206)Pb-labeled trimethyllead (TML) and triethyllead (TEL) were synthesized from (206)Pb-enriched metallic Pb certified reference material (NIST SRM 983) and iodomethane or iodoethane through a one-process reaction in a closed system using centrifuge tubes, respectively. Organolead compounds in an urban dust reference material (BCR CRM 605) were extracted with an acetic acid/methanol (1:1) solution, which was mechanically shaken for 24 h. After adjusting the pH of the extracted solution to pH 5, the extracted organolead compounds were derivatized by tetrabutylammonium tetrabutylborate (TATB) and measured with GC-ICPMS. The analytical results of TML and TEL for BCR CRM 605 were 8.22 +/- 0.04 microg kg(-1) (mean +/- standard deviation, n = 3) and 1.12 +/- 0.06 microg kg(-1), respectively. The analytical results of TML agreed well with the certified value (7.9 +/- 1.2 microg kg(-1)).  相似文献   

12.
Sampling behavior of multielements for NIST SRM 2703, a marine sediment, was studied with sample sizes from 1 mg down to ng level by a combination of INAA, PIXE and SRXRF. On 1 mg sample size level, sampling behavior for multielements in NIST SRM 2703 and its parent SRM 2702 were comparatively characterized by using INAA combining with Ingamells model. Results showed that sampling uncertainties for 12 elements of both materials were found to be better than 1%, and those of four other elements in SRM 2703 better than in SRM 2702. At sample sizes not able to be accurately weighed (<1 mg), PIXE and SRXRF were used and the effective sample sizes estimated. Sampling uncertainties for nine elements were found to be better than 1% at sample sizes of tenth mg level, and those for six elements better than 10% on ng levels.  相似文献   

13.
A reliable and sensitive method for determination simultaneously of monomethylmercury (MeHg) and monoethylmercury (EtHg) in various types of foods by gas chromatography inductively coupled plasma mass spectrometry (GC-ICP/MS) was developed and validated. Samples were digested with pancreatin and then hydrochloric acid. MeHg and EtHg in the extract were derivatized in an aqueous buffer with sodium tetraphenylborate. After phase separation, the extract was directly transferred to analysis. The analyses were conducted by GC-ICP/MS with monopropylmercury chloride (PrHgCl) as surrogate standard. Concentrations of 254±5.1, 13.7±0.69 and 162±6.2 μg Hg kg(-1) (one standard deviation, n=3) were obtained for MeHg in NIST SRM 1947 (Superior Lake fish), SRM 1566b (oyster tissue) and NRC Tort-2 (lobster Hepatopancreas), respectively. These are in good agreement with the certified values of 233±10, 13.2±0.7 and 152±13 μg Hg kg(-1) (as 95% confidence interval), respectively. The method detection limits (3σ) for MeHg and EtHg are 0.3 μg Hg kg(-1). The method detection limit was estimated by using a 0.5 g of subsample, sufficiently low for the risk assessment of MeHg and EtHg in foods. The spiked recoveries of MeHg and EtHg in different food matrices were between 87 and 117% and the RSDs were less than 15%. When isotopic dilution mass spectrometry (IDMS) analysis was performed with a commercial available (201)Hg-enriched monomethylmercury (Me(201)Hg) solution as internal standard, concentrations of 244±13.4, 13.9±0.25 and 161±1.3 μg Hg kg(-1) were obtained for MeHg in NIST SRM 1947, SRM 1566b and NRC Tort-2, respectively. It shown clearly that IDMS analysis got improvement in precision and accuracy, however, EtHg cannot be analyze simultaneously and the cost of analysis is higher.  相似文献   

14.
A stopped-flow injection liquid-liquid extraction (SF-EX-FIA) spectrophotometric method is reported for the determination of palladium(II), using the 2,2'-dipyridyl-2-pyridylhydrazone (DPPH) as a color forming reagent. The colored complex Pd(II)-DPPH was extracted in CHCl(3) and the absorbance was monitored at 560 nm. An injection valve was used as a commutator in order to combine the stopped-flow technique with liquid-liquid extraction FI system. The calibration graph was linear up to 12 mg l(-1) (s(r)=0.27%; r=0.9999) with a detection limit of c(L)=0.007 mg l(-1). The sampling rate was 20 injections per hour. The proposed method has been successfully applied to the determination of palladium in airborne particulate matter (APM) and in automobile exhaust gas converter catalysts.  相似文献   

15.
A sensitive multi-residue analytical method, utilizing ethyl acetate extraction and liquid chromatography-electrospray ionization tandem mass spectrometry (LC-ESI-MS-MS), has been developed and validated for simultaneous determination of 28 pesticides of different chemical classes (polar organophosphates, carbamates, strobilurines, neonicotinoids, amides, pyrimidines, benzimidazoles, imidazoles and triazoles), and their transformation products, in processed fruit and vegetables. Two precursor-product ion transitions were monitored for each pesticide in selected reaction monitoring (SRM) mode. Linearity (r (2) > or = 0.99) was good over the concentration range 0.5 to 100 microg L(-1) for all the pesticides, and instrumental detection limits ranged from 0.1 to 1 microg L(-1). Mean recovery for fruit and vegetables spiked at 0.010 mg kg(-1) ranged from 65 to 94.4%, and relative standard deviations ranged from 9.0 to 20.0%. When the amount spiked was 0.050 mg kg(-1) recoveries ranged from 72.5 to 90% and relative standard deviations were from 6.1 to 19.0%. Method detection limits were from 0.002 to 0.007 mg kg(-1) for the different food matrices studied. The method was used to monitor pesticide residues in a wide variety of fruits and vegetables.  相似文献   

16.
An analytical method using liquid chromatography coupled to mass spectrometry with atmospheric pressure chemical ionization for the determination of polycyclic aromatic hydrocarbons in asphalt fractions has been developed. The 14 compounds determined, characterized by having two or more condensed aromatic rings, are expected to be present in asphalt and are considered carcinogenic and mutagenic. The parameters of the atmospheric pressure chemical ionization interface were optimized to obtain the highest possible sensitivity for all of the compounds. The limits of detection ranged from 0.5 to 346.5 μg/L and the limits of quantification ranged from 1.7 to 1550 μg/L. The method was validated against a diesel particulate extract standard reference material (NIST SRM 1975), and the obtained concentrations agreed with the certified values. The method was applied to asphalt samples after its fractionation according to ASTM D4124 and the method of Green. The concentrations of the seven polycyclic aromatic hydrocarbons quantified in the sample ranged from 0.86 mg/kg for benzo[ghi]perylene to 98.32 mg/kg for fluorene.  相似文献   

17.
We describe the use of hair roots as a matrix for detection of methamphetamine (MP) and 3,4-methylenedioxymethamphetamine (MDMA) abuse. The concentration of drugs was determined in rat hair roots, hair shafts, and plasma after a single administration of MP or MDMA, by use of an HPLC-peroxyoxalate chemiluminescence (PO-CL) method involving column switching. Plasma and hair roots and shafts were collected from male Wistar rats before and after administration of MP (10 mg kg(-1), i.p.). In addition, the roots and shafts of pigmented and non-pigmented hair of male Lister hooded rats were collected after administration of MDMA (10 mg kg(-1), i.p.). The concentrations of MP and MDMA in plasma and hair were determined by use of the HPLC-PO-CL method, with satisfactory sensitivity and reproducibility. The concentration of MP in hair roots 1-14 days after administration ranged from 0.038 to 0.115 ng mg(-1) (n = 3). By use of the HPLC-PO-CL method, MP could be detected in hair roots for longer (up to 14 days) than it could be detected in conventional biological specimens, for example plasma (~1 day), and MDMA was detected in hair roots from 1 to 10 days after administration. The AUC(1-10) (ng day mg(-1)) for MDMA in roots of non-pigmented and pigmented hair was comparable (4.93 ± 2.09 vs. 6.67 ± 1.28, n = 3), whereas AUC(1-14) for hair shafts differed significantly (1.86 ± 0.93 vs. 4.58 ± 0.63, P < 0.05, n = 3). The window for detecting MP (or MDMA) in hair roots under our conditions was 1-14 (or 1-10) days.  相似文献   

18.
A comparison between open microwave digestion and digestion by conventional heating was carried out for the determination of Cd, Cr, Cu, and Pb in two algae matrices using transverse heated electrothermal atomic absorption spectrometry (ETAAS). A SRM GBW 08504 cabbage was also analysed. These matrices were digested with HNO3, using a quartz vessel for microwave digestion and PFA vessel for digestion by conventional heating. Cd, Cu and Cr were determined without any modifier, while magnesium nitrate and ammonium phosphate mixed modifier was used for Pb. Results obtained by both the procedures were in good agreement with each other at 95% confidence level, and for SRM GBW 08504 cabbage the values agree well with the certified values. The limits of detection obtained were 0.0004, 0.060, 0.065 and 0.054 mg/kg for Cd, Cr, Cu, and Pb, respectively, using the microwave digestion process. The RSD for Cd was 10–15% and for the other elements 5–10%.  相似文献   

19.
When mercury is quantified by ICP-MS under routine conditions (external calibration) in reference materials, which require mineralization with nitric acid, the experimental concentrations are almost always unacceptably low in comparison to certified values. Sorption of mercury on the Teflon surfaces of the digestion vessels, changes in the viscosity of the aspirated solutions, in the efficiency of the nebulization, in the aerosol transport, and memory effects cannot be responsible for the low results. The intensity of a mercury signal is strongly dependent on the concentration of nitric acid (and other mineral acids) in the measured solutions. Correct results for mercury in the SRM GBW-90101 (Chinese human hair; 2.16+/-0.21 mg Hg/kg certified) can only be obtained, when the solutions, with which the external calibration curves were established, have exactly the same nitric acid concentration as the aspirated digests (2.03+/-0.01 mg Hg/kg; n = 5), when mercury is determined by the standard addition method (2.10+/-0.01 mg Hg/kg; n = 5), or when the experimental mercury concentration obtained at a nitric acid concentration in the digest, different from the concentration in the external calibration solutions, is corrected mathematically based on a pre-established function [Hg2+] = f [HNO3]. The concentrations found by this mathematically based correction 2.04+/-0.01 mg Hg/kg (n = 5) is in good agreement with the values obtained by acid matched calibration or by the standard addition method. For practical work with large numbers of samples the mathematical correction appears to be the method of choice. For occasional mercury determinations, the standard addition method seems to be the most practicable.  相似文献   

20.
Pressurized Fluid Extraction (PFE) was evaluated for the extraction of polycyclic aromatic hydrocarbons (PAHs) and nitro-derivatives from diesel particulate matter. Extraction conditions were set up by performing several tests in which temperature, solvent strength, pressure, and static time were gradually increased. The results obtained on a laboratory test material made of a "lean" (low content of soluble fraction) Diesel particulate matter indicate that very severe conditions were needed in order to obtain better recoveries of the higher molecular weight molecules. Moreover, extraction efficiency seems to be influenced by the amount of soluble matter in the particulate, so that a "lean" particulate appears more difficult to extract. Recoveries of the deuterated standards of certain PAHs (i.e. indeno[1,2,3- cd]pyrene) were incomplete even with the toughest conditions tested. Experiments carried out on a certified material (SRM 1650 from NIST) also indicate that PFE can perform a better extraction of some of the PAHs than the method used for certification, but still incomplete. Comparison of results obtained on the SRM with different extraction techniques suggests that the composition of the extract varies considerably with the extraction technique and conditions. It is relevant to notice that recent Diesel engines produce leaner particulate: for future materials more drastic extraction conditions will be required.  相似文献   