首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
A capillary electrophoretic method with laser-induced fluorescence detection for baclofen (4-amino-3-p-chlorophenylbutyric acid) has been developed. 6-Carboxyfluorescein succinimidyl ester was used for precolumn derivatization of the non-fluorescent drug. Optimal separation and detection were obtained with an electrophoretic buffer of 50 mM sodium borate (pH 9.5) and an air-cooled argon-ion laser (excitation at 488 nm, emission at 520 nm). Linearity (r > or = 0.99) over three orders of magnitude was generally obtained and the lowest derivatizable concentration limit for baclofen in aqueous solution was 10 nM (2 ng baclofen/ml). Coupled with a simple clean up procedure, the method can be applied to the analysis of baclofen in human plasma at micromolar level. Recovery of spiked baclofen in plasma was 95%. The relative standard deviation values on peak size (0.5 microM level) and migration time were 8.2 and 1.0% (n=7), respectively. The limit of detection of baclofen in plasma was 0.1 microM (21 ng/ml).  相似文献   

2.
An enantioselective method for baclofen (4-amino-3-p-chlorophenylbutyric acid) based on capillary electrophoresis (CE) separation and laser-induced fluorescence (LIF) detection has been developed. Naphthalene-2,3-dicarboxaldehyde (NDA) was used for precolumn derivatization of the nonfluorescent drug. alpha-Cyclodextrin (alpha-CD) was included in the buffer as a chiral selector for the separation of NDA-labeled S-(+)- and R-(-)-baclofen. Optimal resolution and detection were obtained with an electrophoretic buffer of 50 mM sodium borate (pH 9.5) containing 7 mM alpha-CD and a He-Cd laser (lambda ex = 442 nm, lambda em = 500 nm). Combined with a simple cleanup procedure, this method can be applied to the analysis of baclofen enantiomers in human plasma. The relative standard deviation (RSD) values on peak areas of a plasma sample containing 1.0 microM racemic baclofen were 6.4 and 4.9% (n = 8) for the S-(+)- and R-(-)-enantiomer, respectively. The RSD value on migration times of both enantiomers was 0.5% (n = 8). Calibration graphs for S-(+)- and R-(-)-baclofen in plasma showed a good linearity (r > or = 0.999) in the concentration range of 0.1-2.0 microM. The limit of detection of baclofen in plasma was about 10 ng/mL.  相似文献   

3.
A new analytical method for baclofen (4-amino-3-p-chlorophenylbutyric acid) based on capillary electrophoretic separation and laser-induced fluorescence detection has been developed. Naphthalene-2,3-dicarboxaldehyde was used for precolumn derivatization of the non-fluorescent drug. Optimal separation and detection were obtained with an electrophoretic buffer of 50 mM sodium borate (pH 9.5) and a He-Cd laser (excitation at 442 nm, emission at 500 nm). Linearity (r > or = 0.99) over three orders of magnitude was generally obtained and the concentration limit of detection was in the nanomolar level. Coupled with a simple cleanup procedure, the method was successfully applied to the analysis of baclofen in human plasma. Recovery of spiked baclofen in plasma was 98%. The relative standard deviation values on peak size and migration time were 7.9% and 0.4%, respectively. The limit of detection of baclofen in plasma was 10 ng/ml.  相似文献   

4.
Nine racemic arylglycine amides were synthesized and successfully enantioseparated by capillary electrophoresis (CE) using highly sulfated beta-cyclodextrin (HS-beta-CD) as a chiral selector. Baseline enantioseparation of the analytes was obtained around neutral pH but not in the acidic conditions that are commonly used. HS-beta-CD content, buffer pH, type and concentration, and organic modifier concentration were studied and optimized for fast and efficient separation. A chiral CE separation system composed of 1.5% (w/v) HS-beta-CD, 0 to 10% (v/v) methanol and 20 mM 3-(N-morpholino)propanesulfonic acid at pH 6.5 was shown suitable for baseline enantioseparation of the mentioned amides within 6 min, including simultaneous enantioseparation of three positional isomer series (methyl-, methoxyl or chloro-substituted). By using this system, D-enantiomers migrated ahead of the L-enantiomers and the enantiomeric resolution order of arylglycine amides was more or less parallel to the pK(a), order of the analytes.  相似文献   

5.
A sensitive and enantiospecific gas chromatographic method for the determination of the S(+)- and R(-)-enantiomers of baclofen (I and II) in plasma and urine has been developed and validated. The method is based on the complete resolution of the derivatized enantiomers on a chiral fused-silica capillary column. The hydrochloride salt of a (-)-fluoro analogue of baclofen (III.HCl) was used as the internal standard in plasma, the hydrochloride salt of a (+)-fluoro analogue of baclofen (IV.HCl) as the internal standard in urine. Rapid and convenient isolation of the compounds was achieved using reversed-phase Bond-Elut C18 columns. After elution, the compounds were converted into isobutyl esters and purified by base-specific solvent extraction. The isobutyl esters were then N-acylated with heptafluorobutyric anhydride. The derivatives were quantitated after separation on the chiral column using electron-capture detection. The analysis of spiked plasma and urine samples demonstrated the good accuracy and precision of the method, with limits of quantitation of 25 nmol/l for I and II in plasma and of 2 mumol/l for I and II in urine. The method appears to be suitable for use in pharmacokinetic studies of the enantiomers in plasma and urine from animals and man after administration of the racemic baclofen.  相似文献   

6.
芳基甘氨酰胺的手性毛细管电泳拆分   总被引:1,自引:0,他引:1  
郭磊  林双君  杨义芳  齐莉  王梅祥  陈义 《色谱》2002,20(5):407-410
 研究了 9种自行合成的芳基甘氨酰胺的手性拆分。以高硫酸化 β 环糊精为手性选择剂 ,在中性而不是常用的强酸性条件下 ,于 6min内基线拆分了全部芳基甘氨酰胺。考察了高硫酸化 β 环糊精浓度、缓冲液类型及浓度、有机添加剂及其含量等对拆分的影响 ,得到优选拆分体系组成为 :1 5g/L高硫酸化 β 环糊精 ,0或 1 0 % (体积分数 )甲醇 ,2 0mmol/L 3 (N 吗啡啉 )丙磺酸 ,pH 6 5。 9种芳基甘氨酰胺的 D 构型均先于 L 构型出峰 ,初步讨论了芳基甘氨酰胺结构与出峰顺序的关系。  相似文献   

7.
Zhou Q  Yau WP  Chan E 《Electrophoresis》2003,24(15):2617-2626
A capillary zone electrophoresis (CZE) method with direct ultraviolet (UV)-absorbance detection is presented for the simultaneous enantiomeric separation of warfarin and its main metabolites, including warfarin alcohols, 4'-, 6-, and 7-hydroxywarfarin, using highly sulfated beta-cyclodextrin (HS-beta-CD) as the chiral selector. This chiral separation method was optimized in terms of the electrophoretic parameters, which included the concentration of HS-beta-CD used, the type and composition of organic modifier added to the background electrolyte (BGE) buffer, and the BGE buffer pH. Chiral separation of warfarin and its major metabolites was achieved with high resolution, selectivity, efficiency, repeatability, and reproducibility. This optimized chiral analysis of warfarin along with its metabolites was completed within a satisfactory electrophoresis time of 20 min.  相似文献   

8.
Baclofen is used to manage alcohol dependence. This study describes a simple method using liquid chromatography coupled to high‐resolution mass spectrometry (LC‐HR‐MS) developed in plasma samples. This method was optimized to allow quantification of baclofen and determination of metabolic ratio of its metabolites, an oxidative deaminated metabolite of baclofen (M1) and its glucuronide form (M2). The LC‐HR‐MS method on Exactive® apparatus is a newly developed method with all the advantages of high resolution in full‐scan mode for the quantification of baclofen and detection of its metabolites in plasma. The present assay provides a protein precipitation method starting with 100 μL plasma giving a wide polynomial dynamic range (R 2 > 0.999) between 10 and 2000 ng/mL and a lower limit of quantitation of 3 ng/mL for baclofen. Intra‐ and inter‐day precisions were <8.1% and accuracies were between 91.2 and 103.3% for baclofen. No matrix effect was observed. The assay was successfully applied to 36 patients following baclofen administration. Plasma concentrations of baclofen were determined between 12.2 and 1399.9 ng/mL and metabolic ratios were estimated between 0.4 and 81.8% for M1 metabolite and on the order of 0.3% for M2 in two samples.  相似文献   

9.
L Ersoy 《The Analyst》1990,115(12):1559-1560
A fluorodensitometric method was developed for the determination of baclofen. The method is based on the reaction of baclofen with 4-chloro-7-nitrobenzofurazan and measurement of the fluorescence intensity at 540 nm after chromatographic separation on a silica-gel plate. A linear relationship was found between relative fluorescence intensity and concentration over the range 4-100 ng of baclofen per spot. The detection and determination limits are 0.4 and 4.0 ng of baclofen per spot, respectively. The method was applied to human plasma. The recovery of baclofen from plasma was 96.67%.  相似文献   

10.
A simple and robust analytical method for rapid separation and sensitive quantification of baclofen in human plasma by capillary electrophoresis technique was developed. Electrophoretic separation was optimized and successfully performed using simple sodium tetraborate aqueous solution. Observed detection limit in biological material was 10 ng. Using UV detection at 200 nm excellent linearity (r = 0.999) was observed over the concentration range from 0.025 to 1.0 microg mL(-1). The described method has been validated and applied to the quantitative determination of baclofen in human plasma. The bioavailability of Baclofen (Polpharma) and Lioresal (Novartis) in 18 healthy volunteers was investigated. The results indicate bioequivalence of the reference and Baclofen preparations.  相似文献   

11.
Matrix-assisted laser-desorption ionization time-of-flight (MALDI-TOF) mass spectrometry (MS) and nuclear magnetic resonance (NMR) spectroscopy were employed to characterize two different sulfated beta-cyclodextrins (HS-beta-CD). It was found that the HS-beta-CDs have broad heterogeneity in terms of sulfation degree. The average sulfate contents were in the range of 6 to 8 per CD molecule. Furthermore the sugar moieties of both HS-beta-CDs were sulfated either at position 6 or at positions 2 and 6, but not at position 3. Enantiomeric separation by capillary zone electrophoresis (CZE) using the HS-beta-CDs as chiral selectors showed that these CDs exhibited similar chiral selectivity and resolution of the ephedrine enantiomers. One of the CDs was employed for the enantiomeric purity evaluation of (1R,2S)-ephedrine (or (-)-ephedrine) by capillary zone electrophoresis. Quantification was done by comparison between the corrected peak areas of the minor enantiomer and (-)-ephedrine.  相似文献   

12.
The separation of dipeptide and tripeptide enantiomers using a neutral single isomer cyclodextrin (CD) derivative, heptakis-(2,3-di-O-acetyl)-beta-CD (DIAC-beta-CD), was investigated with respect to the amino acid sequence applying standard separation conditions. With only one exception the DD-enantiomers migrated faster than the LL-stereoisomers. Separations obtained for the same set of peptides using beta-CD and the sulfated single isomer derivatives heptakis-(2,3-di-O-acetyl-6-sulfo)-beta-CD (HDAS-beta-CD) and heptakis-6-sulfo-beta-CD (HS-beta-CD) revealed identical enantiomer migration order in the presence of the 2,3-disubstituted derivatives DIAC-beta-CD and HDAS-beta-CD. In contrast, reversed migration sequence was found for beta-CD and HS-beta-CD compared to DIAC-beta CD and HDAS-beta-CD indicating the importance of the substitution pattern on the wider rim of the CD cavity on the chiral recognition of the peptide enantiomers by the CDs. Nuclear magnetic resonance (NMR) experiments indicated different complexation modes between the enantiomers and the CDs depending on the presence of acetyl substituents on the wider rim of the CD torus. Thus, the CD-induced chemical shifts observed in samples containing Ala-Phe or Ala-Tyr and beta-CD or HS-beta-CD were consistent with an inclusion of the aromatic moiety into the CD cavity. Although the CD-induced chemical shifts in the presence of DIAC-beta-CD and HDAS-beta-CD did not allow direct conclusions on the complexation mode they substantially differed from those observed in the presence of 2,3-unsubstituted CDs indicating different structures of the peptide-CD complexes.  相似文献   

13.
The formation of inclusion complexes between methoxypoly(ethylene glycol)s (MPEG)s bearing one hydrophobic group (phenyladamantyl) per chain and beta-cyclodextrin (beta-CD) was studied by capillary electrophoresis (CE). The effect of highly sulphated beta-CD (HS-beta-CD) on the migration behaviour of the phenyladamantyl-modified MPEG (MPEG-PhAd) analyte was investigated. It was established that the interaction between the modified PEG and beta-CD involved a 1:1 stoichiometry. Non-linear regression and three usual linearization methods (y-reciprocal, x-reciprocal and double reciprocal) were employed to estimate the binding constants. It was demonstrated that the binding constants were similar (around 400 M(-1)) for two MPEG-PhAd having different chain lengths (2000 and 5000 g/mol).  相似文献   

14.
Wang Y  Yang J  Cai Y  Lin X  Li H 《色谱》2011,29(12):1230-1235
以4-氯-7-硝基苯并-2-氧杂-1,3-二唑(NBD-Cl)为柱前衍生试剂,建立了胶束电动色谱-激光诱导荧光检测法测定肌松弛药巴氯芬(BAL)的新方法。经过实验条件的优化,采用15 mmol/L硼砂、20 mmol/L十二烷基硫酸钠、10%(v/v)乙腈、pH 9.75的缓冲体系,在分离电压为17.5 kV、柱温为25 ℃的条件下,压力进样3.45 kPa(0.5 psi)×3 s,巴氯芬及其内标物的衍生产物在7 min内实现较好的基线分离,线性范围为0.025~25 mg/L,相关系数为0.9999,检出限(S/N=3)和定量限(S/N=10)分别为0.90 μg/L和6.25 μg/L。该方法被应用于巴氯芬制剂及加入巴氯芬对照品的尿液样品分析,回收率范围分别为101.6%~107.9%和107.0%~109.6%。该方法有望应用于巴氯芬药物制剂的质量监控以及为巴氯芬药物代谢的研究提供辅助手段。  相似文献   

15.
Hefnawy MM  Aboul-Enein HY 《Talanta》2003,61(5):667-673
A new analytical method for the separation and determination of R-(−)- and S-(+)- baclofen enantiomers in human plasma by high-performance liquid chromatography (HPLC) with UV detection was developed. Enantioselective resolution of the baclofen enantiomers was achieved by using teicoplanin macrocyclic antibiotic chiral stationary phase (CSP) known as Chirobiotic T with a polar ionic mobile phase (PIM) consisting of methanol: glacial acetic acid: triethylamine, 100:0.1:0.1, (v/v/v) at a flow rate of 0.5 ml min−1 and UV detection set at 220 nm. The analytes of interest with S-(+)-sulpiride as the internal standard were extracted from human plasma using liquid-liquid extraction procedure with ethyl ether under alkaline condition prior to HPLC analysis. Recoveries for R-(−)- and S-(+)-baclofen enantiomers were in the ranges of 96-103% at 60-2500 ng ml−1 level. Intra-day and inter-day precision calculated as %RSD was in the ranges of 1.2-5.2 and 1.3-4.3% for both enantiomers, respectively. Intra-day and inter-day accuracy calculated as percentage error were in the ranges of 1.2-3.9 and 1.1-3.9% for both enantiomers, respectively. Linear calibration curves in the concentration ranges of 20-3000 ng ml−1 for each enantiomer showed correlation coefficient (r) of 0.9997. The limit of quantitation (LOQ) and limit of detection (LOD) for each enantiomer in human plasma were 20 and 10 ng ml−1 (S/N=3) respectively.  相似文献   

16.
A high-performance liquid chromatographic (HPLC) method was developed for chiral assay of baclofen enantiomers in pharmaceutical formulations using an indirect approach. Baclofen enantiomers were derivatized with Marfey's reagent (FDNP-L-Ala-NH2) and its structural variants FDNP-L-Phe-NH2, FDNP-L-Val-NH2, FDNP-L-Leu-NH2 and FDNP-L-Pro-NH2. The resultant diastereomers were separated on RP-TLC [triethylammonium phosphate buffer (pH 4.0, 50 mm)-acetonitrile, 50:50] and on a C18 column using a linear gradient (45 min) of acetonitrile and 0.01% aqueous trifluoroacetic acid (TFA) with UV detection at 340 nm. The differences in the retention times (Delta t R) of diastereomers due to the five chiral reagents were compared. The maximum and minimum difference in retention times between separated diastereomers was for FDNP-L-Leu-NH2 and FDNP-L-Pro-NH2, respectively. The effect of flow rate, acetonitrile content and TFA concentration on resolution was studied. The method was validated for linearity, repeatability, limit of detection and limit of quantification.  相似文献   

17.
The baclofen‐MWCNTs‐Pd nanocatalyst was synthesized through covalent grafting of baclofen molecules onto surface‐modified carbon nanotubes and immobilizing Pd nanoparticles by the baclofen ligands. The chemical structure of the produced nanocatalyst was studied by Raman spectroscopy, Fourier transform‐infrared spectroscopy, energy‐dispersive spectroscopy (EDS), elemental mapping and inductively coupled plasma analysis. Also, its surface morphology was determined using the scanning and transmission electron microscopy techniques. Furthermore, the obtained baclofen‐MWCNTs‐Pd nanocatalyst is demonstrated to exhibit very high activity as a heterogeneous phosphine‐free catalyst in Sonogashira cross‐coupling of aryl halides by giving good to excellent yields of different products. In addition, the nanocatalyst can be reused four times without any significant leaching or loss of activity.  相似文献   

18.
The stability of the o-phthalaldehyde (OPA) derivatives of sisomicin obtained using beta-mercaptopropionic acid was investigated by reversed-phase high-performance liquid chromatography. One of the fluorescent derivatives of sisomicin was stable at least for 6 h in 50% methanol under the optimal conditions used (OPA concentration, pH and temperature). When plasma samples spiked with sisomicin were analysed, the response was linear in the calibration range 136-900 pg of sisomicin per injected volume (40 microliters). As little as 0.06 micrograms of sisomicin per 1 ml of plasma could be detected with signal-to-noise ratio greater than or equal to 2. For plasma samples spiked with 0.2 micrograms/ml sisomicin, the recovery was 97.1 +/- 6.6% (mean +/- S.D., n = 5) with a within-run coefficient of variation of 6.8% and a day-to-day coefficient of variation of 7.2%. The method was also applied to plasma samples from rabbit after a subcutaneous injection of 1 mg/kg sisomicin.  相似文献   

19.
Two methods are presented for the determination of 'respectively' the plasma protein unbound and total concentration of acyclovir in horse plasma and body fluids: first, a liquid-liquid extraction was performed on plasma, combined with HPLC-fluorescence detection for the total plasma concentration; second a more sensitive method using high-performance liquid chromatography combined with heated electrospray ionization tandem mass spectrometry (LC-HESI-MS/MS) was described for plasma and for body fluids analysis. To obtain the unbound concentration of acyclovir in plasma, a simple deproteinization step using a Microcon filter was performed. Ganciclovir was used as an internal standard. Analysis was carried out on an Inertsil 5 ODS-3 column for the HPLC-fluorescence method. For the LC-HESI-MS/MS method a PLRP-S column was used. The limit of quantification (LOQ) for the total concentration was set at 50 and 2 ng mL(-1) for the HPLC-fluorescence method and the LC-HESI-MS/MS method, respectively. The limit of quantification for the unbound concentration was set at 5 ng mL(-1) and at 2 ng mL(-1) for body fluids. The methods were successfully used to perform pharmacokinetic and clinical studies in horses after intravenous and oral dosage of acyclovir and its prodrug valacyclovir.  相似文献   

20.
(15R)-15-Methylprostaglandin E2 (PGE2) is a pro-drug under evaluation for the treatment of acute upper gastrointestinal hemorrhage and gastrointestinal cytoprotection. It is converted in acid (e.g., gastric fluid) to its active 15S epimer. Both epimers are found in human plasma at low pg/ml levels following oral dosing. A high-performance liquid chromatographic (HPLC) method was developed for the simultaneous analysis of (15R)- and (15S)-15-methyl-PGE2 in human plasma. The method combined off-line solid-phase extraction and reversed-phase HPLC clean-up with panacyl bromide derivatization and subsequent analysis using a heteromodal column-switching technique. Assay linearity was demonstrated over a range of 10-200 pg/ml for both 15-methyl-PGE2 epimers (r greater than or equal to 0.995). There were no significant inter-day differences in assay results for either epimer at 50 and 25 pg/ml (p greater than 0.05), with pooled estimates of precision at these levels producing relative standard deviations of less than or equal to 8% and less than or equal to 12%, respectively. The method quantitation limit (signal-to-noise ratio 5:1) for both epimers was 10 pg/ml when processing 3 ml of plasma. The analysis procedure was shown to be useful for quantifying at or below 10% of the (15R)-15-methyl-PGE2 maximum plasma concentration following a 50-micrograms oral dose in three human volunteers. For the same three subjects, however, the plasma concentration of (15S)-15-methyl-PGE2 did not exceed the quantitation limit of 10 pg/ml.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号