首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 62 毫秒
1.
A procedure based on solid-phase extraction (SPE) has been developed for the simultaneous preconcentration of three widely used herbicides and seven of their most common degradation products. The compounds studied were atrazine and its metabolites, desethylatrazine, desethyldesisopropylatrazine (DEDIA), 2-hydroxyatrazine, desethyl-2-hydroxyatrazine and desisopropyl-2-hydroxyatrazine (DIHA), terbutryne and its metabolite 2-hydroxyterbutylazine, and chlorotoluron and its metabolite 3-chloro-4-methylphenylurea. A HPLC system with diode array detection was used for the separation, identification and quantification of all these analytes. In the SPE preconcentration step, different types of sorbent were studied: C18 on silica and polymeric sorbents (Oasis and LiChrolut EN), the best results being obtained with the styrene–divinylbenzene cartridge and when the elution was performed with methanol and ethyl acetate. The detection limits obtained were between 0.1 μg l−1 for DIHA and DEDIA and 0.02 μg l−1 for the other analytes. The method used permitted the determination of these herbicides in drinking water at the concentration levels demanded by current legislation. The proposed method was used to evaluate the presence and evolution with time of these herbicides and their degradation products in samples of surface and ground waters from agricultural zones of the provinces of Salamanca and Zamora (basins of the Rivers Guareña and Almar), Spain.  相似文献   

2.
A comprehensive comparison of four different polymeric solid-phase extraction (SPE) materials for the extraction of 22 different aromatic sulfonates of environmental concern was performed. The investigated adsorbents were the polystyrene–divinylbenzene materials LiChrolut EN from Merck, Isolute ENV+ from International Sorbent Technology, HR-P from Macherey–Nagel and the new Oasis HLB poly(divinylbenzene-co-N-vinylpyrrolidone) copolymer from Waters. Different SPE parameters like the elution solvent and the drying step of the cartridges were optimized. Analyses were performed by capillary zone electrophoresis–UV absorbance detection (CZE–UV) and ion-pair liquid chromatography–diode array UV detection coupled in series with electrospray mass spectrometry (IP-LC–DAD-ESI-MS) in the negative ionization mode. LC–MS offers a higher separation efficiency than CZE. The best adsorbents were LiChrolut EN and HR-P followed by Isolute ENV+ and Oasis HLB. The recoveries for most of the onefold negatively charged aromatic sulfonates were >50% for the extraction from spiked ground water at 50 μg/l. Recoveries for LiChrolut EN and HR-P were approximately 20% higher than for Isolute ENV+. Very hydrophilic sulfonates containing more than one negative sulfonate group could not be extracted by any of the tested adsorbents.  相似文献   

3.
The determination of polar and nonpolar organophosphorus compounds, triazines and their metabolites, molinate and chlorothalonil in 1 l water samples was investigated using off-line solid-phase extraction followed by gas chromatography with nitrogen-phosphorus and flame photometric detection. The ethylvinylbenzene-divinylbenzene copolymer (LiChrolut EN) and the commercial graphitized carbon black (GCB) of Envi-Carb were tested as solid-phase sorbents. The matrix effect was studied by extracting the compounds spiked in water samples of different types (Milli-Q, tap, salted tap water, river and sea water). The polymeric sorbent LiChrolut EN allowed the determination at low ng/l of all 40 compounds tested, except the very polar atrazine-desethyl-deisopropyl (DDA). Recoveries of compounds from the Envi-Carb sorbent are comparable to those obtained for LiChrolut EN with the exception of chlorothalonil and the more hydrophobic organophosphorus compounds (coumaphos, leptophos), which were strongly sorbed in the Envi-Carb cartridges. Envi-Carb, however, enabled the determination of DDA with a limit of detection of 14 ng/l.  相似文献   

4.
Haloacetic acids (HAAs) were determined in different water samples by a new, fast and simple analysis method based on enrichment of 50-ml water samples at pH 1.8 by solid-phase extraction (SPE) followed by liquid chromatography (LC) separation and electrospray ionization mass spectrometric detection in the negative ionization mode. Deprotonated (M-H)-haloacetates and decarboxylated (M-COOH)- ions were detected. Different polymeric SPE sorbents were tested, and LiChrolut EN was found to be the best material for the extraction. Complete LC separation of all compounds could only be achieved by ion-pair chromatography using triethylamine as volatile ion-pairing reagent. The detection limits were in the low microg/l range. High microg/l concentration levels for the chlorinated and brominated haloacetates were found in drinking water from a drinking water treatment plant in Barcelona, and the corresponding tap water. In swimming pool water samples from Catalonia mg/l levels and in surface river water from Portugal microg/l values were detected. These results confirm other recent reports on the ubiquitous occurrence of HAAs in aqueous environments.  相似文献   

5.
Summary The potential of a non-aqueous, capillary electrophoresis (NACE) system for separating oxytetracycline from three of its impurities—tetracycline, 4-epioxytetracycline and 4-epitetracycline—using UV detection has been studied. The running buffer was: 25 mM sodium acetate, 1 mM EDTA, methanesulfonic acid, pH 4, dissolved in MeOH-ACN (50∶50,v/v). The method was also used to determine these compounds in pig plasma. A solid-phase extraction (SPE) procedure as a clean-up step has also developed. For this we tested Sep Pak C18, LiChrolut EN and OASIS cartridges. OASIS cartridges were best. Recoveries were 90–100% for all compounds except EOTC which had a recovery of 74%.  相似文献   

6.
《Analytica chimica acta》2004,503(2):271-278
In this work, a capillary electrophoresis (CE) method for the determination of a group of eleven triazine compounds by micellar electrokinetic capillary chromatography (MEKC) with diode array detection was developed. The eleven herbicides studied were: desethylatrazin-2-hydroxy (DEA), simazine, prometon, atrazine, simetryn, ametryn, propazine, prometryn, trietazine, terbutylazine, and terbutryn The separation of these compounds was optimised as a function of buffer concentration and pH, concentration of sodium dodecyl sulphate (SDS) and voltage applied. To increase the selectivity of the separation and the resolution of the solutes, different organic solvents were tested as buffer additives, obtaining the best results when 1-propanol was used. The optimised buffer (24 mM of sodium borate, 18 mM of disodium hydrogen phosphate, 25 mM of SDS, pH 9.5, and 5% of 1-propanol) provides the best separation in terms of resolution and migration time. This method allowed the determination of these compounds at concentrations of 0.05 μg l−1 in ground water samples pretreated using solid-phase extraction (SPE).  相似文献   

7.
A method of capillary electrophoresis (CE) for the determination of triazine herbicides and some of their main metabolites in water samples has been developed. The proposed CE method includes an off-line solid-phase extraction (SPE) procedure with LiChrolut EN sorbent coupled to a non-aqueous capillary electrophoresis (NACE) separation with UV detection. The target compounds were the chloro-s-triazines simazine, atrazine, propazine; the methyltio-s-triazines ametryn and prometryn and three main derivatives from the atrazine degradation products; namely, deethylatrazine, deethylhydroxyatrazine and deisopropylhydroxyatrazine. The analytical characteristics of the CE method are reported. The repeatability of the method was studied considering the different steps of the method separately in order to determine the contributions of each step to the total variability of the method. The NACE-UV results are compared with those obtained with a high performance liquid chromatography with UV detection (HPLC-UV) method. The same off-line SPE procedure was applied to both techniques. The results obtained show that both methods afford the same results in the analysis of surface and drinking water samples, with a level of significance regarding the F- and t-tests greater than 0.05 in all the cases. The detection limits in surface water samples were in the 0.04-0.32 microg l(-1) and 0.11-1.2 microg l(-1) ranges for the NACE-UV and HPLC-UV methods, respectively. The recoveries (spiked/found) were significantly 100% in all cases.  相似文献   

8.
Two new generation polymeric resins, Bond Elut ENV (styrene-divinylbenzene) from Varian and LiChrolut EN (ethylvinylbenzene-divinylbenzene) from Merck, commonly used in liquid--solid-phase extraction (SPE) were evaluated as sorbents for gas-phase sampling followed by thermal desorption and compared to Tenax TA, a reference sorbent in this kind of applications. The three resins were tested against seven volatile organic compounds (VOCs): 1-octene, ethylbenzene, (p-, m-, o-)xylenes, styrene and 1,4-dichlorobenzene. Elution curves for all compounds were determined at temperatures from 120 to 180 degrees C, and from such curves, different parameters, such as retention factor (k), distribution coefficient (K), height equivalent to a theoretical plate (H), asymmetry factor (Fa) and breakthrough volume (VB) were calculated and extrapolated at room (25 degrees C) and desorption (220 degrees C) temperatures in order to estimate breakthrough and elution volumes. In average, retention in LiChrolut EN is 10 and 200 times stronger than in Bond Elut ENV and Tenax TA, respectively, but its chromatographic behavior is rather poor giving quite asymmetric elution profiles (Fa >1.8 at 120 degrees C). Bond Elut ENV exhibited the best chromatographic behavior, with H values two or five times lower than those of LiChrolut EN or Tenax TA. An additional advantage of the new sorbents is that retention decreases with T much faster than it does in Tenax (8 or 20 times for Bond Elut ENV or LiChrolut EN). Modeling has finally shown that beds with 60-80 (for Bond Elut ENV) or 300-400 (for LiChrolut EN) times less of sorbent have the same retention properties than standard Tenax TA tubes and similar (LiChrolut EN) or five to six times smaller (Bond Elut ENV) elution volumes. These predictions have been experimentally confirmed.  相似文献   

9.
A portable and time-integrating field sampler based on the supported liquid membrane (SLM) extraction technique was constructed. Using two programmable syringe pumps and one programmable valve, the sampler could carry out automatic unattended extraction for up to seven extracts, combining the steps of sampling, trace enrichment and clean-up. The sampler was applied to the extraction of four s-triazine herbicides (atrazine, cyanazine, prometryn and terbutryn) and six major degradation products of s-triazines, including three dealkylated products (deethyl deisopropyl atrazine (DDA), deisopropyl atrazine DIA and deethyl atrazine (DEA)) and three hydroxylated products (hydroxy atrazine (ATOH), hydroxy propazine (PROH) and hydroxy terbutylazine (TZOH)). The donor solution was obtained by mixing sample and buffer, consisting of 1?M phosphate buffer at pH 7.0 and 1.7?M NaCl, in the ratio of 19?:?1 (v/v). Extraction was performed by continuously pumping 10?mL portions of donor along the SLM until 3?L of sample had been extracted. The SLM consisted of di-n-hexylether and the acceptor was 1?M HCl. After extract collection, extracts were neutralised with NaOH and buffered with phosphate. Extracts were analysed with HPLC, using a gradient elution consisting of 3.5?mM phosphate and acetonitrile and UV-detection at 220?nm. Enrichment factors in reagent water ranged from 1.3 (for DIA) to 2739 (for terbutryn). The developed field sampler was tested by carrying out 24-h time-weighted on-site extraction of the ten s-triazine target compounds in Hawassa Lake and its tributary river, located in the agricultural region of the Southern Rift Valley of Ethiopia. Atrazine, cyanazine and terbutryn were generally below the method detection limit, while prometryn was frequently found. Overall, s-triazines were not persistent in the studied environment and degradation products of s-triazines were found in higher concentrations than the parent herbicides in both the river and the lake.  相似文献   

10.
任晋  蒋可  徐晓白 《色谱》2004,22(2):147-150
建立了高效液相色谱-质谱联用(HPLC-MS)选择离子检测(SIM)分析环境土样中的痕量莠去津及其降解产物脱乙基莠去津(deethylatrazine,DEA)、脱异丙基莠去津(deisopropylatrazine,DIA)、羟基化莠去津(HA)的方法。土样用双蒸水超声提取,然后用Waters Oasis MCX固相萃取小柱富集纯化土样提取液,测得莠去津及其降解物在不同加标浓度(4.5~120 ng/g)下的回收率为:莠去津40.4%~82.0%,DEA 60.6%~86.5%,DIA 69.2%~86  相似文献   

11.
固相萃取-高效液相色谱法测定环境水样中的三嗪类化合物   总被引:17,自引:0,他引:17  
李竺  陈玲  郜洪文  董丽娴  赵建夫 《色谱》2006,24(3):267-270
建立了固相萃取-高效液相色谱法(SPE-HPLC)测定地表水中三嗪类化合物的方法。考察了4种不同固相萃取柱对三嗪类化合物的吸附效果,最终选择ENVI-18固相萃取柱用于萃取地表水中的三嗪类化合物;系统研究了环境水样中三嗪类化合物的最佳固相萃取条件,选择洗脱溶剂为甲醇,洗脱溶剂用量5 mL,水样在萃取前不需要添加甲醇,不调节pH值。测定了方法的检测限,结果表明,扑草净、莠去津、西玛津、脱乙基莠去津、羟基化莠去津和脱异丙基莠去津的最低检测限依次为0.14 μg/L,0.12 μg/L,0.08 μg/L,0.08 μg/L,0.10 μg/L和0.18 μg/L。将该法应用于实际环境水样的分析测定,结果表明某湖水中扑草净的含量为(9.33±0.27) μg/L,某江水中莠去津和扑草净的含量分别为(5.28±0.43) μg/L和(7.12±0.54) μg/L。  相似文献   

12.
Adsorption properties of the clay mineral montmorillonite in the potassium homoionic form (KMT) was investigated to achieve the extraction and concentration of the herbicides atrazine (AT) and propazine (PROP), as well as the main degradation products of atrazine, namely deethylatrazine (DEA), deisopropylatrazine (DIA) and hydroxyatrazine (ATOH). A batch approach was proposed, with recovery percentages for AT, PROP and DIA higher than 90% at concentrations of 0.50 and 2.50 μg L−1. For DEA and ATOH, however, low recoveries were obtained. For DEA, this fact can be explained by its low Kd with KMT, contrary to ATOH, which interacts strongly with the mineral surface, hindering the complete desorption and hence, generating low recovery percentages. The influence of pH, ionic strength and humic acid was studied, and a comparison with the C18 phase as SPE cartridges was carried out. Montmorillonite showed a similar performance to commercial cartridge for concentrations of AT, DEA and PROP, but better recoveries for DIA was obtained using the clay mineral. For ATOH the recovery was also higher on the clay mineral, although for this compound the most suitable SPE cartridge is constituted by cation exchange resin. After the concentration and elution steps, the 0.50 and 2.50 μg L−1 gave chromatographic peak areas that could be easily quantified with an analytical curve obtained in the concentration range between 7.5 and 100 μg L−1. The obtained concentration factors are suitable to allow the application of the method to the monitoring of triazine residues in drinking water.  相似文献   

13.
An automatic method for determining diuron, irgarol 1051, folpet and dichlofluanid in seawater samples have been developed. This method is based on the on-line coupling of solid-phase extraction (SPE) with a highly crosslinked polymeric sorbent, LiChrolut EN, to liquid chromatography followed by atmospheric pressure chemical ionization (APCI) and mass spectrometry. The operational parameters affecting the APCI interface have been studied in both positive and negative ionization modes. The use of LiChrolut EN in the SPE produced recoveries of over 85% for all the compounds when 100 ml of seawater sample was preconcentrated. Calibration was carried out in both ionization modes and in full-scan and selected-ion monitoring (SIM). The method allowed all the analytes to be detected at 5 ng l(-1) in SIM acquisition mode except folpet, which, because of its low response, could only be detected at 250 ng l(-1). The method was used to analyse water samples taken from five different marina and fishing ports along the coast of Tarragona, Catalonia (Spain), over a 5-month period. Diuron and irgarol 1051 were detected and quantified in most samples at concentration levels ranging from 27 to 420 ng l(-1) for diuron and from 15 to 511 ng l(-1) for irgarol 1051.  相似文献   

14.
In this study, in‐line solid‐phase extraction (SPE) was used as an enrichment technique in combination with CE for the preconcentration and separation of 2‐ethylidene‐1,5‐dimethyl‐3,3‐diphenylpyrrolidine (EDDP), cocaine (COC), codeine (COD) and 6‐acetylmorphine (6AM). The separation buffer (BGE) used was 80 mM disodium phosphate anhydrous and 6 mM of HCl (final BGE pH of 3). The SPE extractor consists of a small segment of capillary filled with Oasis HLB sorbent and inserted into the inlet section of the electrophoretic capillary. Different parameters affecting preconcentration were evaluated, such as sample pH, the volume of the elution plug and sample injection time. The detection limits (LODs) reached for standard samples by in‐line SPE‐CE‐UV ranged between 50 and 200 ng/L, with sensitivity enhancement factors ranging from 2300 to 5300. Reproducibility values (expressed in terms of relative standard deviation) were below 7.6% for standard samples. This is a simple and an effective method for the determination of the studied drugs of abuse and their metabolites. The applicability of the developed method was demonstrated in tap and river water samples which were directly analyzed without any off‐line pretreatment. Analytical parameters were evaluated and LODs were between 70 and 270 ng/L with relative recoveries between 85 and 97%.  相似文献   

15.
Cloud point extraction (CPE) and solid phase extraction (SPE) methods were developed for the determination of ??g l?1 of vanadium ions in surface, tap and bottled mineral water samples, based on the rapid reaction of vanadium(V) with 8- hydroxyquinoline (8-quinolinol) at pH 3?C5. Both the sensitive extraction methods were successfully employed for the preconcentration of V in real samples. For CPE, V complexed with 8-quinolinol and then was entrapped in non-ionic surfactant Triton X-114, while for SPE, V was adsorbed on XAD -2 impregnated with 8-quinolinol. The experimental conditions for SPE (pH, eluent, and contact time between the liquid sample and the resin) and CPE (pH of sample solution, concentration of 8- quinolinol and Triton X-114, equilibration temperature and time period for shaking) were investigated in detail. The validity of SPE/CPE of V was checked by certified reference material of water (SRM-1643e). The extracted surfactant-rich phase (200 ??l) was mixed with 200 ??l of HNO3 in ethanol and this final volume was injected into electrothermal atomic absorption spectrometry with different modifiers. Under these conditions, the preconcentration of 25 ml sample solution allowed the raising of an enrichment factor of 100 and 10 folds for CPE and SPE, respectively. The concentration of V in surface water (river and lake), tap water and bottled mineral water samples was found to be in the range of 1.30?C19.9, 1.05?C5.25 and 0.67?C1.21 ??g l?1, respectively.  相似文献   

16.
建立了高效液相色谱-串联质谱法(HPLC-MS/MS)同时检测土壤中阿特拉津及其降解产物残留的分析方法。样品以甲醇-水(4∶1,V/V)作为提取溶剂,使用涡旋振荡提取,采用HPLC-MS/MS法进行测定,外标法定量。在0.01、0.2和5.0mg/kg三个添加浓度水平下,阿特拉津及其降解产物的平均回收率在73.7%~104.7%之间,相对标准偏差为0.4%~5.1%;阿特拉津,羟基阿特拉津在土壤样品中的方法检出限均0.045μg/kg,而脱乙基阿特拉津、脱乙基脱异丙基阿特拉津及脱异丙基阿特拉津在土壤样品中的方法检出限则分别为0.090、0.45和0.90μg/kg。本方法的灵敏度较高,且简便、快速,能较好的解决目标物极性差别大及样品基质对检测结果的干扰等问题,可以满足土壤中阿特拉津及其降解产物残留检测的需要。  相似文献   

17.
A capillary zone electrophoresis (CZE) method with UV-vis detection has been developed for the simultaneous monitoring of the major degradation products of metribuzin, i.e. deaminometribuzin (DA), deaminodiketometribuzin (DADK) and diketometribuzin (DK). The dissociation acid constants have also been estimated by CE and no significant differences have been observed with the values obtained by applying other techniques. Optimum separation has been achieved in less than 9 min in 40 mM sodium tetraborate buffer, pH 9.5 by applying a voltage of 15kV at 25 degrees C and using p-aminobenzoic acid as internal standard. In order to increase sensitivity, large volume sample stacking (LVSS) with polarity switching has been applied as on-line pre-concentration methodology. Detection limits of 10, 10 and 20 ng/mL for DA, DADK and DK, respectively were obtained. The method has been applied to soil samples, after pressurized liquid extraction (PLE). Samples were extracted at high temperature (103 degrees C and 1500 psi) using methanol as extraction solvent and sodium sulphate as drying agent. This PLE procedure was followed by an off-line pre-concentration and sample clean-up procedure by solid-phase extraction (SPE) using a LiChrolut EN sorbent column. These last two procedures were also suitable for the direct treatment of groundwater samples before CE analysis. The combination of both off-line and on-line pre-concentration procedures provided a significant improvement in sensitivity. LVSS provided pre-concentration factors of 4, 36 and 28 for DK, DA and DADK, respectively and with SPE a pre-concentration of 500-fold for the case of water samples and of 2.5-fold in the case of soil samples was obtained. The method is suitable for the monitoring of these residues in environmental samples with high sensitivity, precision and satisfactory recoveries.  相似文献   

18.
A simple, semi-automated, microcolumn solid-phase extraction (SPE) system is optimized for the extraction, preconcentration and HPLC analysis of seven different explosives and explosive derivatives contaminating seawater, river water and well water samples. The microcolumns were constructed from 1/16 in. O.D. PTFE tubing (1 in.=2.54 cm) packed with 0.5-1.5 mg of SPE material. LiChrolut EN or Porapak R. The extraction system consisted of two syringe pumps and several solenoid valves. Optimal detection limits were realized when the sample water flow-rate was maximally increased within the limits of the pump, 5-10 ml/min (despite exceeding the breakthrough threshold of the SPE microcolumn), and when the eluate volume collected from the column was minimized, <5 microl (despite very low recovery percentages).  相似文献   

19.
A new synthesized copolymer based on N-vinylimidazole-divinylbenzene (VIm-DVB) was tested as a sorbent for the solid-phase extraction (SPE) of polar analytes. In the on-line SPE, this synthesized sorbent enabled 100 ml of sample to be preconcentrated with recoveries as high as 80% for oxamyl, phenol (Ph) and derivates, bentazone and (4-chloro-2-methylphenoxy)acetic acid (MCPA). For the off-line SPE, 1000 ml of sample was extracted and recoveries were higher than 92% for all compounds with the exception of oxamyl (83%) and methomyl (78%). The VIm-DVB sorbent gives better recoveries than the previously synthesized 4-vinylpyridine-divinylbenzene (VP-DVB) resin and similar to such highly crosslinked commercial sorbents as LiChrolut EN or Oasis HLB. Real water samples were used to validate the on-line SPE method. Linearity was good and detection limits were between 0.1 and 0.2 microg l(-1).  相似文献   

20.
A multiresidue method developed for the analysis of atrazine and its principal conversion products, deisopropylatrazine (DIA), deethylatrazine (DEA) and hydroxyatrazine (HA), in soil is presented. The method is based on the microwave-assisted extraction (MAE) of soil with aqueous methanol followed by solid-phase extraction (SPE) of the extracts and subsequent analysis by LC–UV with a diode array detector. MAE operational parameters (extraction solvent, extractant volume) were optimized with respect to extraction efficiency of the target compounds from soils with 2.5% organic matter (OM) content. Recoveries above 80% were obtained for all solutes. Soil OM content did not affect analyte recoveries. Recoveries from fresh and aged residues, the latter weathered under cold storage conditions, were not statistically different. Finally, MAE was found to be superior in terms of extraction efficiency, sample throughput, and solvent consumption to conventional flask-shaking extraction.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号