首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 500 毫秒
1.
A one-fourth scale model of the large (425 m3) National Bureau of Standards reverberation room is described. This facility was constructed to carry out acoustical research at relatively low cost in a frequency range two octaves higher than that used in the larger facility. Initial experimental measurements carried out in this facility concern sound power emitted by small sources. The pure tone qualification procedure specified in American National Standard S1.21-1972 ‘Metods for the Determination of Sound Power Levels of Small Sources in Reverberation Rooms’ was carried out using computer control of the experiment. This standard is of particular interest to the international acoustical community since it is technically equivalent to ISO Documents DIS 3741 and DIS 3742. The effect of increased low frequency absorption upon room qualification was tested in the model room. Future research plans to make use of the small-scale reverberation rooms are described.  相似文献   

2.
C. Hopkins  P. Turner 《Applied Acoustics》2005,66(12):1339-1382
Procedures for the field measurement of airborne sound insulation between rooms with diffuse fields are described in International Standard ISO 140-4. However, many dwellings contain rooms with volumes less than 50 m3, where low frequency measurements are less reliable; hence there is a need for a measurement procedure to improve the reliability of field measurements in rooms with non-diffuse fields. Procedures are proposed for sound pressure level and reverberation time measurements for the 50, 63 and 80 Hz third octave bands. The sound pressure level measurement combines corner microphone positions with positions in the central region of each room. This provides a good estimate of the room average sound pressure level with significantly improved repeatability.  相似文献   

3.
A set of experiments was carried out to validate an optimization procedure based on finite element method (FEM). The idea of the procedure, fully presented in previous edition of this journal [Zhu X, Zhu Z, Cheng J. Using optimized surface modifications to improve low frequency response in a room. Appl Acoust 2004;65:841-60], is to produce an optimal geometry modification on the wall for improving low frequency sound uniformity in small rooms. Four experimental models were set up with a scale of 1:5. One was modified according to the optimized result and the others were treated with no optimization consideration. Measured frequency responses of four rooms were compared with numerical results calculated by FEM models. The transient responses in these rooms were also measured and analyzed. The agreements between calculation and measurement are satisfactory though the discrepancies due to the uncertainty of acoustic behavior of the room boundaries remain. The optimization procedure has been supported by the results that the optimized room produces the flattest frequency response and also the most smooth energy decay within the frequency range studied. The reductions of response fluctuation have reached 4.3 dB for prediction and 2.6 dB for measurement, respectively.  相似文献   

4.
Acoustic analysis of a liquefied petroleum gas-fired pulse combustor   总被引:1,自引:0,他引:1  
Experimental investigation of acoustic characteristics of a Helmholtz type liquefied petroleum gas-fired pulse combustor is presented. In the experiments, the length of the tail pipe was changed from 1.9 m to 1.3 m by 10 cm intervals. Sound level measurements were taken from the exhaust side (outlet) and air flapper side (inlet) at a distance of 1 m from both sides. With decreasing lengths of the tail pipe, the sound pressure level increased. At the measurements related to the exhaust side, the maximum value of equivalent continuous sound pressure level, LEQ was 96.6 dB when the length of the tailpipe and fundamental frequency were 1.3 m and 63 Hz, respectively. Same kinds of measurements were performed at the air flapper side, but the LEQ value was stronger at the exhaust side than the one at the air flapper side. It was also observed that the effect of the type of gaseous fuel on the acoustic efficiency of the pulse combustor can be neglected when the results of the acoustic efficiencies were compared to those in the literature. In order to compare the accuracy of frequencies measured by the sound level meter, a suitable dynamic pressure transducer and a spectrum analyzer were used to perform amplitude and frequency measurements. The average deviation between the measurements performed by the sound level meter and dynamic pressure transducer was 2.4 Hz (3.8% errors) while the average deviation was 3.8 Hz (6% errors) between the sound level meter and spectrum analyzer.  相似文献   

5.
An experimental implementation of a global sound equalization method in a rectangular room using active control is described in this paper. The main purpose of the work has been to provide experimental evidence that sound can be equalized in a continuous three-dimensional region, the listening zone, which occupies a considerable part of the complete volume of the room. The equalization method, based on the simulation of a progressive plane wave, was implemented in a room with inner dimensions of 2.70 m × 2.74 m × 2.40 m. With this method, the sound was reproduced by a matrix of 4 × 5 loudspeakers in one of the walls. After traveling through the room, the sound wave was absorbed on the opposite wall, which had a similar arrangement of loudspeakers, by means of active control. A set of 40 digital FIR filters was used to modify the original input signal before it was fed to the loudspeakers, one filter for each transducer. The optimal arrangement of the loudspeakers and the maximum frequency that can be equalized is analyzed theoretically in this paper. The presented experimental results show that sound equalization was possible from 10 Hz to approximately 425 Hz in the listening zone. A flat frequency response with deviations within ±5 decibels from the desired value was achieved. A higher demanding performance with deviations within ±1.5 decibels from a flat frequency response was attained in the interval between 20 Hz and 280 Hz. At the same time, the impulse response was quite well approximated to a delayed delta function in the listening zone. Examples of the spatial distribution of the sound field are also shown.  相似文献   

6.
The increasing presence of low frequency sources and the lack of acoustic standard measurement procedures make the extension of reverberation time measurements to frequencies below 100 Hz necessary. In typical ordinary rooms with volumes between 30 m3 and 200 m3 the sound field is non-diffuse at such low frequencies, entailing inhomogeneities in space and frequency domains. Presence of standing waves is also the main cause of bad quality of listening in terms of clarity and rumble effects. Since standard measurements according to ISO 3382 fail to achieve accurate and precise values in third octave bands due to non-linear decays caused by room modes, a new approach based on reverberation time measurements of single resonant frequencies (the modal reverberation time) has been introduced. From background theory, due to the intrinsic relation between modal decays and half bandwidth of resonant frequencies, two measurement methods have been proposed together with proper measurement procedures: a direct method based on interrupted source signal method, and an indirect method based on half bandwidth measurements. With microphones placed at corners of rectangular rooms in order to detect all modes and maximize SNRs, different source signals were tested. Anti-resonant sine waves and sweep signal turned out to be the most suitable for direct and indirect measurement methods respectively. From spatial measurements in an empty rectangular test room, comparison between direct and indirect methods showed good and significant agreements. This is the first experimental validation of the relation between resonant half bandwidth and modal reverberation time. Furthermore, comparisons between means and standard deviations of modal reverberation times and standard reverberation times in third octave bands confirm the inadequacy of standard procedure to get accurate and precise values at low frequencies with respect to the modal approach. Modal reverberation time measurements applied to furnished ordinary rooms confirm previous results in the limit of modal sound field: for highly damped modes due to furniture or acoustic treatment, the indirect method is not applicable due to strong suppression of modes and the consequent deviation of the acoustic field from a non-diffuse condition to a damped modal condition, while standard reverberation times align with direct method values. In the future, further investigations will be necessary in different rooms to improve uncertainty evaluation.  相似文献   

7.
This work presents sound insulation and sound reflection measurements conducted over sonic crystal noise barriers according to the European standards EN 1793-2, EN 1793-5 and EN 1793-6. In most of the reference literature, sound insulation and reflection properties of sonic crystals are measured or a diffuse sound field or in a direct sound field including the top and side edge diffraction effects together with the transmitted (or reflected) components. The aim of this work is to perform free-field measurements over a real-sized sample in order to window out all diffraction components and to verify the points of strength and weakness of the application of standardised measurements to sonic crystals. Diffuse field measurements in laboratory are also done for comparison purposes. Since the target frequency range for traffic noise spectrum is centred at around 1000 Hz, a finite element based parametric investigation is performed to design unit cells capable of generating band gaps in the one-third octave bands ranging from 800 Hz to 1250 Hz. Then, 3 × 3 m sonic crystal noise barriers are installed in the Laboratory of the University of Bologna and sound insulation and sound reflection measurements are performed according to the mentioned active standards for normal incidence. Sound insulation is measured for diffuse incidence too. The two methods give different results. The method more directly comparable to calculations is the free-field one. However, if on the one hand the application of a time window allows to compute the transmitted or reflected component only, on the other hand the time window itself limits the maximum width of the sample for which all reflections of the n-th order having a significant spectral content are included, and thus results critical in the analysis of this kind of noise barriers. Nevertheless, the standardised measurements allow a direct comparison between the performance of sonic crystals and common noise barriers.  相似文献   

8.
In the current paper, which deals with the noise pollution excited by distribution transformers in the living area, a comprehensive treatment scheme is put forward for the purpose of reducing the sound pressure level emitting into the environment. In accordance with the associated test standard, the sound pressure levels of distribution transformer and surrounding environment are not only tested but analyzed as well. The measurements were carried out with the frequency analysis of the 1/3 octave resolution, with the center frequencies at 125 Hz, 250 Hz, 400 Hz, and 500 Hz. As illustrated, on the basis of the measurement results, the frequency of noise at 500 Hz of distribution transformer causes the major noise pollution in the surrounding environment. This measurement result is in line with the noise frequency characteristics of distribution transformer. There are two transmission routes of noise: i) the noise excited by distribution transformer transmits by means of the wall of distribution room, and ii) part of noise spreads through the ground of distribution room. Accordingly, acoustic shield and vibration isolation device are applied for the reduction of the low frequency noise emitted through the above two paths. Aimed at applying the appropriate acoustic material and vibration mounting, the evaluation of the noise reduction and vibration absorption is carried out in accordance with the sound and vibration insulation theory. Following the noise treatment, the transformer and environment noise are measured again. The corresponding findings shed light on the fact that the sound level satisfied the requirement of limits of the ordinance. The proposed noise treatment scheme can be applied to the existing power distribution facilities for controlling the sound levels that reach a point where it is comparatively more unobjectionable.  相似文献   

9.
Structure-borne noise originating from a heat pump unit was selected to study the influence on subjective annoyance of low frequency noise (LFN) combined with additional sound. Paired comparison test was used for evaluating the subjective annoyance of LFN combined with different sound pressure levels (SPL) of pink noise, frequency-modulated pure tones (FM pure tones) and natural sounds. The results showed that, with pink noise of 250-1000 Hz combined with the original LFN, the subjective annoyance value (SAV) first dropped then rose with increasing SPL. When SPL of the pink noise was 15-25 dB, SAV was lower than that of the original LFN. With pink noise of frequency 250-20,000 Hz added to LFN, SAV increased linearly with increasing SPL. SAV and the psychoacoustic annoyance value (PAV) obtained by semi-theoretical formulas were well correlated. The determination coefficient (R2) was 0.966 and 0.881, respectively, when the frequency range of the pink noise was 250-1000 and 250-20,000 Hz. When FM pure tones with central frequencies of 500, 2000 and 8000 Hz, or natural sounds (including the sound of singing birds, flowing water, wind or ticking clock) were, respectively, added to the original sound, the SAV increased as the SPL of the added sound increased. However, when a FM pure tone of 15 dB with a central frequency of 2000 Hz and a modulation frequency of 10 Hz was added, the SAV was lower than that of the original LFN. With SPL and central frequency held invariable, the SAV declined primarily when modulation frequency increased. With SPL and modulation frequency held invariable, the SAV became lowest when the central frequency was 2000 Hz. This showed a preferable correlation between SAV and fluctuation extent of FM pure tones.  相似文献   

10.
Two experiments explored how frequency content impacts sound localization for sounds containing reverberant energy. Virtual sound sources from thirteen lateral angles and four distances were simulated in the frontal horizontal plane using binaural room impulse responses measured in an everyday office. Experiment 1 compared localization judgments for one-octave-wide noise centered at either 750 Hz (low) or 6000 Hz (high). For both band-limited noises, perceived lateral angle varied monotonically with source angle. For frontal sources, perceived locations were similar for low- and high-frequency noise; however, for lateral sources, localization was less accurate for low-frequency noise than for high-frequency noise. With increasing source distance, judgments of both noises became more biased toward the median plane, an effect that was greater for low-frequency noise than for high-frequency noise. In Experiment 2, simultaneous presentation of low- and high-frequency noises yielded performance that was less accurate than that for high-frequency noise, but equal to or better than for low-frequency noise. Results suggest that listeners perceptually weight low-frequency information heavily, even in reverberant conditions where high-frequency stimuli are localized more accurately. These findings show that listeners do not always optimally adjust how localization cues are integrated over frequency in reverberant settings.  相似文献   

11.
If variations and uncertainty in building acoustic measurements can be controlled, construction costs can potentially be reduced since the building will not have to be acoustically over-designed. Field measurements of impact and airborne sound insulation were carried out for an industrially prefabricated cross-laminated timber (CLT) system of plate elements. The results from 18 rooms, forming three groups with respect to size, were compared to a similar study dealing with a prefabricated Volume Based Building (VBB) system. Large variations were found at frequencies below 100 Hz which is crucial for the low frequency adaptation terms connected to the weighted sound insulation indices. The measurement uncertainty was investigated by analysing the repeatability, measurement direction and the time dependence of the sound source. The variations due to the measurement procedure were found to be small compared to the total variations. It was also indicated that the variations in sound insulation are smaller with a prefabricated system compared to on-site production, since less work is required at the building site.  相似文献   

12.
In the papers by Larsen [1] and Brüel [2], two interesting problems connected with reverberation room measurements are pointed out and discussed. The first problem is that the ensemble averaged decay curve reveals a monotonic curvature at low frequencies. The second phenomenon is that often systematically larger sound power output values are reported at low frequencies according to the free field method than according to the reverberation room method. In searching for an explanation of these anomalies some measurements and a classical normal mode theory analysis have been made. It is shown that it is not possible to explain fully the curvature of the low frequency decay curves by means of the normal mode theory. The measured curves are more bent than the respective theoretical ones. Most probably, it should be possible to explain this lack of agreement by the fact that the absorption characteristics of normal reverberation chambers significantly deviate from the situation of uniform wall admittance which has been assumed in the theoretical deductions. The theoretical analysis and the comparison between theory and practice indicate that the damping characteristics of the individual waves vary much more than is predicted for a uniform wall admittance. This reasoning is supported by the observation that the monotonic curvature increases when a plane concentrated absorbent is added to one of the walls. One way to decrease the curvature has also been identified. When the room surfaces are provided with randomly placed small samples of low frequency absorbents the resulting decay curves turn out to be almost perfectly linear. Furthermore, it is found that the normal mode theory does not imply significantly different sound power output values than the ISO 3741 model. This fact has been verified with a comparative test. According to the normal mode theory the average sound power output as measured in the reverberant room should equal the free field output. Therefore, one is forced to conclude that the analysis of the classical normal mode theory fails in explaining the anomalies observed.  相似文献   

13.
Recent progress in the development of European standards has allowed the in situ testing of roadside noise barriers. CEN/TS 1793-5 describes a test method using maximum length sequences (MLS) for the characterisation of airborne sound insulation. However, many barriers are tested according to a laboratory standard, EN 1793-2, based on measurements carried out in reverberant chambers and in the case of timber barriers with a relatively low airborne sound insulation it is not clear to what extent the results of the two tests compare. The paper describes the results of tests carried out using both methods. Six samples of timber barrier were compared including single-leaf and double-leaf constructions and single-leaf constructions with an absorptive core. Very good agreement was found especially when account was taken of the valid frequency range in each test method. The results open up the possibility of routinely evaluating the performance of timber barriers at the roadside where build quality can be variable and there are concerns that the acoustic performance may not match that obtained under laboratory test conditions where typically the barrier is more carefully constructed.  相似文献   

14.
一种现场测量材料吸声特性的新方法   总被引:8,自引:0,他引:8  
匡正  叶超  吴鸣  杨军 《声学学报》2010,35(2):162-168
现有的材料吸声系数测量方法主要有混响室法和驻波管法,都属于实验室测量方法,不适合现场测量。使用普通扬声器的反射法可以对材料的吸声特性进行现场测量,但是对材料尺寸和测试环境有较高的要求。本文利用参量阵非线性自解调可听声的高指向性和在阵长距离内的平面波特性,结合传递函数法,测量材料的吸声系数,并与传统驻波管测量结果进行了对比。结果表明在普通房间条件下,不需要驻波管,混响室等实验环境,即可对小尺寸的材料进行吸声系数的现场快速测量,具有较大的实用性。   相似文献   

15.
In the acoustic consulting, testing, design and engineering work of the Fraunhofer-Institute of Building Physics (IBP) the low-frequency end of the noise spectra and the room acoustic conditioning has gained tremendous importance over the years. For solving the long-ranging noise pollution from e.g. exhaust stacks and chimneys, a series of low-frequency sound attenuators with minimum flow resistance were developed. Its first representative was a novel membrane absorber [10] [Ackermann U, et al., Sound absorbers of a novel membrane construction. Applied Acoustics 1998;25:197-215]. Thanks to its slenderness and ruggedness it could also be employed for noise control and reverberation adjustment purposes in relatively narrow enclosures and harsh environments [11] and [12] [Vér IL. Enclosures and wrappings. In: Harris CM, editor. Handbook of acoustical measurements and noise control. New York: McGraw-Hill, 1991; Fuchs HV, Hunecke J. The room plays its part at low frequencies. Das Musikinstrument 1993;42:40-6 (in German). Meanwhile a new type of panel absorber has been optimized for both kinds of application. Its absorption efficiency at frequencies far below 100 Hz could be demonstrated and quantified by a special measuring procedure based on the reverberation of a small rectangular room at its eigenfrequencies [3] (Zha X, et al. Measurements of an effective absorption coefficient below 100 Hz. Acoustics Bulletin 1999;24:5-10). With the aid of this novel tool it is now possible to qualify reverberation rooms and anechoic chambers for frequencies down to 63 and 31 Hz, respectively [9] (Fuchs HV, et al. Qualifying freefield and reverberation rooms for frequencies below 100 Hz. Applied Acoustics 2000;59:303-22). In a companion paper in this same journal [4] [Fuchs HV, et al.: Creating low-noise environments in communication rooms. Applied Acoustics (in print)] appropriate experience is reported in creating low-noise environments in multi-purpose rooms like offices, restaurants, foyers and seminars. A number of representative case studies [5] (Drotleff H, et al. : Attractive acoustic design of multi-purpose halls. 1. Chinese-German Platform Innovative Acoustics 2000, (October, 21-25. 2000)) show ample evidence that the low-frequency performance of the rooms has a strong influence on both the amplification of intruding external noise and the development of internally generated noise emanating from communication processes provoked by the users themselves. At work places where producing sound (by voices or/and instruments) is the main or only purpose for their existence, the acoustic qualification of the room at low frequencies turns out to be of the utmost importance, especially when musicians are forced to work in extremely narrow spaces like orchestra pits and rehearsal halls for many hours a day and often under extreme physical and mental pressure. The measures taken and described herein have proven to mitigate if not remove some of the acoustic burden put on musicians employed in states theatres.  相似文献   

16.
The aeroacoustic wind tunnel at Brandenburg University of Technology at Cottbus is a newly commissioned research facility for the experimental study of sound generation from bodies immersed in a fluid flow. The paper discusses the design criteria for the open jet wind tunnel that provides a maximum wind speed of 72 m/s at continuous operation and may be operated with nozzles of different dimension between 35 cm diameter (circular nozzle) and 12 cm by 14.7 cm (rectangular nozzle). Experiments may be performed either in a reverberant or in an anechoic environment. Both the aerodynamic and the acoustic design of the wind tunnel components are discussed in detail. Background noise measurements in the completed facility revealed very low levels comparable to other wind tunnels. The results of aerodynamic wind tunnel calibration confirmed a uniform flow quality in the jet and a very low axial turbulence intensity which is less than 0.2% for the 35 cm nozzle and less than 0.1% for the other nozzles. A final benchmark is provided by results of successful trailing edge noise measurements on an SD7003 airfoil that are presented and compared to results from the literature.  相似文献   

17.
In several auditoria, it has been observed that the reverberation time is longer than expected and that the cause is a horizontal reverberant field established in the region near the ceiling, a field which is remote from the sound absorbing audience. This has been observed in the Boston Symphony Hall, Massachusetts, and the Stadthalle Göttingen, Germany. Subjective remarks on their acoustics suggest that there are no unfavourable comments linked to the secondary sound field. Two acoustic scale models are considered here. In a generic rectangular concert hall model, the walls and ceiling contained openings in which either plane or scattering panels could be placed. With plane panels, the model reverberation time (RT) was measured as 53% higher than the Sabine prediction (frequency 500/1000 Hz), compared with 8% higher with scattering panels. The second model of a 300 seat lecture theatre with a 6 m or 8 m high ceiling had raked seating. In this case, the amount of absorption in the model was increased until the point was reached where speech had acceptable intelligibility, with the early energy fraction, D ? 0.5. For this acceptable speech condition with the 6 m ceiling, the measured mid-frequency T15 was 1.47 s, whereas the Sabine predicted RT was 1.06 s. The sound decay was basically non-linear with T30 > T15 > EDT. Exploiting a high-level horizontal reverberant field offers the possibility of acoustics that are better adapted as suitable for both speech and unamplified music, without any physical change in the auditorium. Using secondary reverberation in an auditorium for a wide variety of music might also be beneficial.  相似文献   

18.
The direction-of-arrival (DOA) tracking performance of microphone arrays having aperture sizes ranging from 0.3 to 34 m is examined for an experiment involving a vehicle traversing a moderately complex terrain. A segment of the vehicle’s path was obscured behind a small, 6.7-m high, vegetated hill. The combination of the hill and upwind propagation created an acoustic shadow during this segment. DOA tracks were estimated with a minimum-variance distortionless response (MVDR) beamformer operating in two frequency bands: 25-60 Hz and 60-105 Hz. In the lower frequency band, array sizes between 1 and 8 m gave the best results, with DOA errors between 2° and 5°. Furthermore, in this band shadowing from the hill and wind refraction had a minimal affect on DOA error. In the higher frequency band, the acoustic shadow zone produced a distinct interval of high DOA error, with the 8-m array giving the best overall performance. Modeling of the beamforming process shows that high DOA errors corresponded to MVDR wavenumber patterns that are degraded by distortions to the propagating wavefronts. Our experimental results indicate that small acoustic arrays with apertures less than 0.3 m, operating at frequencies above 100 Hz, should be considered line of sight sensors. Given the moderate complexity of the test conditions, it is anticipated that the observed effects are likely to be present in most attempts to localize outdoor sound sources.  相似文献   

19.
提出了一种吸顶式传声器阵列阵元坐标的标定方法。针对在混响声场中,时延估计算法性能严重下降从而导致在标定传声器阵元坐标时产生较大误差的问题,提出了利用脉冲声源作为标定声源,并且截取脉冲源直达声的方法来抑制混响声场的影响,提高传声器阵元坐标标定的精度。建立了阵元坐标标定的误差分析模型,并以白噪声和脉冲声源作为标定声源进行数据仿真和对比分析。仿真结果表明,使用脉冲声源作为标定声源能有效地抑制混响声场的影响,获得传声器阵列阵元的准确坐标。同时,在封闭的房间内建立起孔径为3.5 m、64阵元的螺旋状吸顶传声器阵列进行了实验研究,实验结果验证了本文提出方法的有效性。   相似文献   

20.
A case study of improving sound energy distribution at low frequency in a small orthogonal room is presented in this paper. The effects of the geometric modifications of wall surface on the sound frequency response have been investigated in depth. In order to find the optimal modifications for the wall surface, an optimization procedure, based on finite element analysis, has been developed. The uniqueness of this method is that it takes both modal redistribution and sound diffusion into account during optimization process. As a result, the promising improvements of sound frequency response have been obtained at the frequencies around 100 Hz in all rooms tested, particularly in those where the serious modal concentrations are met. The maximum reduction of sound fluctuation in such a room could reach a mount of 4.6 dB. The work opens up the possibility of improving low frequency sound quality by a means that considers both modal changing and surface scattering at same time.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号