以氩电弧等离子体法制备的碳包铁纳米粒子为固相萃取材料,采用等离子体原子发射光谱法(ICP-AES)系统研究了该材料对Cr、Ni、Cd、Pb离子的吸附性能,并确定了最佳吸附和洗脱条件。实验结果表明:当pH值为8.0~9.0时,分析物均可被碳包铁纳米粒子定量吸附;采用酸性溶液(pH=1.0~2.0)可将吸附在碳包铁纳米粒子上的金属离子完全脱附。该法对Cr、Ni、Cd、Pb的检出限分别为3.6、4.1、1.1、9.8μg/L,Cr、Ni、Cd的线性范围为1~500μg.L-1,Pb的线性范围为10~1 000μg.L-1,线性相关系数均大于0.999。方法用于自来水中Cr、Ni、Cd、Pb离子的测定,回收率可达到93%~105%;碳包铁纳米粒子对Cr、Ni、Cd、Pb离子的吸附量分别为3.6、4.8、6.3、2.1 mg/g。  相似文献   

2.
基于磁性纳米Fe3O4对砷的选择性富集作用,建立了电感耦合等离子体原子发射光谱(ICP-OES)测定水溶液中砷的方法.考察了溶液酸度、吸附时间、吸附剂用量、试液体积和共存离子等因素对不同形态砷分离富集效率的影响.结果表明,在pH 2~10范围内,选用6.0 mg纳米Fe3O4定量富集,振荡2 min后,三价砷、五价砷、一甲基砷以及二甲基砷等均可被磁性纳米Fe3O4定量富集.线性范围为0.063~20 mg/L; 检出限(3σ)为0.0189 mg/L; 对砷标准溶液测定的相对标准偏差为1.27%(n=6).用本方法对自来水中加入的砷标准溶液进行了测定,回收率为100.3%~104.8%.本方法简便快速,可用于复杂基体中低含量砷的富集分离和测定.  相似文献   

3.
经清洗的不锈钢食具容器中加入乙酸(4+96)溶液至规定体积,煮沸30min,冷却,补充乙酸溶液至原体积,在室温浸泡24h,所得溶液用于原子发射光谱法测定其中的12种元素的含量。选择强度相对较高且干扰较少的谱线作为所测定元素的分析线,对3项仪器工作参数进行了优化,结果表明:发生器射频功率1 250W;载气流量0.6L·min-1;观测高度16mm。12种元素的质量浓度均在0.05~1.0mg·L-1范围内与其谱线强度之间呈线性关系,其检出限(3s)在0.001~0.013mg·L-1之间。对方法的回收率进行了试验,测得回收率在98.2%~104%之间,对浸出液平行测定10次,测定值的相对标准偏差均小于3.0%。  相似文献   

4.
采用电感耦合等离子体原子发射光谱(ICP-AES)法同时测定工业废水中铅、镉、铬和砷。对仪器的工作参数和被测元素的分析谱线进行了优化和选择。方法的检出限依次为0.008,0.002,0.007,0.015 mg.L-1。在质量浓度为0.489 mg.L-1(Pb),0.086 6 mg.L-1(Cd),0.231 mg.L-1(Cr)及0.395 mg.L-1(As)的水平上按试验方法测定8次,作了精密度试验,测得相对标准偏差值依次为1.71%,1.22%,0.95%及1.40%。在两个废水样品的基础上作了加标回收试验,所得结果在95.4%~104.6%之间。  相似文献   

5.
干净的不锈钢厨具样品(5.0 cm×5.0 cm)用乙酸浸泡24 h后,采用电感耦合等离子体原子发射光谱法(ICP-AES)测定不锈钢厨具中铬、镍、镉、铅,采用氢化物发生-ICP-AES测定其中砷的迁移量。研究了介质的酸度、硼氢化钾浓度对砷信号强度的影响,并考察了其他元素对砷测定的化学干扰。选择波长为267.716,231.604,214.438,220.353,193.695 nm 5条谱线依次作为测定铬、镍、镉、铅和砷的分析线。铬、镍、镉、铅和砷的检出限(3s)分别为0.032,0.026,0.006,0.033,0.007 5 mg.L-1,相对标准偏差(n=10)依次为0.7%,0.8%,3.1%,1.2%,3.6%。应用此法测定样品中5种元素测定值与国标法GB/T 5009.81-2003的测定值相比,两种方法所得结果相一致。  相似文献   

6.
仿真饰品样品用模拟人体环境的酸性汗液萃取60min后,采用电感耦合等离子体原子发射光谱法测定其中砷、钡、镉、钴、铬、汞、镍、铅、锑和硒的迁移量。试验选择波长为193.759,233.527,214.438,228.616,267.716,194.227,232.003,220.353,206.833,196.090nm的10条谱线依次作为测定砷、钡、镉、钴、铬、汞、镍、铅、锑和硒的分析线。方法的检出限(3sb/k)在0.002~0.06mg.L-1之间,测定下限(15sb/k)在0.01~0.3mg.L-1之间。方法用于仿真饰品的分析,回收率在88.0%~100%之间,测定值的相对标准偏差(n=7)在3.1%~9.8%之间。  相似文献   

7.
电感耦合等离子体发射光谱法测定仿真首饰中镍释放量   总被引:1,自引:0,他引:1  
建立了电感耦合等离子体发射光谱测定仿真饰品中镍释放量的方法.等离子体流量为15.0 L/min,观察高度为10mm,镍的分析线为231.604 nm.镍含量在0~5 mg/L范围内与仪器响应值呈良好的线性关系,线性相关系数r=0.9999.2.0 mg/L镍标准溶液测定结果的相对标准偏差为1.9%(n=6),方法的检出限为8μg/L.用该方法对参考样品进行测定,测定结果在参考值范围内.  相似文献   

8.
在我国局部都存在不同程度的铅、镉、砷和铬的土壤和水资源污染,土壤和水域中的有毒有害元素经食物链累积在人体,对人们的身体造成极大的危害,因此对食品中这些限量元素进行准确高效定量非常必要。本文建立了微波消解-电感耦合等离子体质谱(ICP-MS)法对小麦粉中的Pb、Cd、As和Cr进行测量,测量方法采用内标法,内标元素选择Rh、In和Bi。另外对微波消解前处理方法和ICP-MS使用参数进行了优化,测量方法简单高效。工作标准曲线呈良好的线性关系,相关系数均大于0.9999。该方法采用GBW(E)100493小麦粉标准物质和NIST 1567b Wheat Flour对本实验所采用的方法进行验证,结果显示测量值和标准值一致,表明本实验中小麦粉中Pb、Cd、As和Cr的测定方法是准确可靠的。  相似文献   

9.
建立了真空蒸馏预富集-电感耦合等离子体发射光谱法测定铅试样中微量铂的方法.在真空条件下,利用Pb和Pt在较高温度下蒸汽压的差别进行分离,富集后的铂溶解制成溶液后进行电感耦合等离子体发射光谱检测,实现了真空密闭回收铅.针对试样的特点,对真空蒸馏方法理论上的可行性进行研究.结果表明:在蒸馏温度为1250 K,真空度为30 Pa,蒸馏时间为3 h条件下,铂的富集分离效果最好,可富集至99.01%以上.线性范围为0.023~20 mg/L,检出限(3σ)为0.0069 mg/L,对样品测定的相对标准偏差为1.7%(n=6).用本方法对样品中加入的铂标准溶液进行了测定,回收率为99.8%~103.0%.本方法简便快速、无污染,已应用于废电路板贵金属冶余物料中铂的测定.  相似文献   

10.
用常规酸消解法或微波消解法消解样品,电感耦合等离子体原子发射光谱法(ICP-AES)测定了玩具包装物中的铬、镉、汞、铅的含量.对六价铬、镉、汞、铅的总含量超过100 mg·kg-1的样品,用共沉淀分离消解液中三价铬后,再用ICP-AES测定六价铬的含量,建立了玩具包装物中六价铬、镉、汞、铅的快速分析方法.方法的回收率为91.2%~103.5%,相对标准偏差(n=11)均小于3%.  相似文献   

11.
《Analytical letters》2012,45(15):2257-2268
An analytical procedure was developed for determination of Hg, As, Pb, and Cd in soil samples using sequential injection vapor generation atomic fluorescence spectrometry (SI-VG-AFS) with sample preparation by microwave digestion system. The effects of analytical conditions on the fluorescence intensity were investigated and optimized. Under the optimized condition, the detection limits of the method were 5, 68, 40, and 3 ng L?1 for Hg, As, Pb, and Cd, respectively. The accuracy of method was verified by the determination of the certified reference soil, and the recoveries for Hg, As, Pb, and Cd were in the range of 98.7–106.1%. The proposed method has been successfully applied to determine the heavy metals in navel orange orchard soils in Ganzhou, and the environmental quality of the orchard soils was assessed based on the content of the heavy metals. According to the second criterion of environmental quality standard for soils, Pb content in all soil samples collected from the orchards of 18 districts were within safe limits, but a few orchards were slightly contaminated with Hg, As, and Cd. Comparison of heavy metal mean concentrations with the safe limits of environmental quality standard for soils, the quality of Ganzhou navel orange orchard soils were in line with the request of the green food production base.  相似文献   

12.
冰铜的成分比较复杂,若酸溶后直接利用电感耦合等离子体原子发射光谱法测定贵金属的含量,杂质元素含量过高,干扰较为严重,导致结果偏差较大。为了准确地测定冰铜样品中的金、银、钯的含量,本试验首先用铅试金法在高温熔融状态下去除冰铜样品中的大部分杂质元素将贵金属富集到铅扣中,将铅扣灰吹除铅后得贵金属合粒,利用二次试金补正试验结果,用醋酸洗涤两次试金得到合粒后称量质量,合粒经硝酸溶解将金与其他元素分离,称量金粒质量,分金液中加入适量的盐酸溶液继续加热处理,然后采用电感耦合等离子体原子发射光谱仪在选定的最佳仪器工作条件下测定分金液中的金、铅、铋、铜、钯的浓度,通过给定的公式计算得出冰铜样品中金、银、钯的含量。试验讨论了氧化铅用量、灰吹温度以及基体干扰对测定结果的影响,当氧化铅加入量为200g,灰吹温度为890℃时,试验效果最好,干扰试验表明,样品中银的含量高低均不会对Au、Pb、Bi、Cu和Pd的测定产生影响。试验结果表明,银加标回收率在97.7 %~100.4 %之间,金的加标回收率在98.6 %~102.2 %之间,钯的加标回收率在98.0%~101.6%之间。该方法操作简单,在测定冰铜样品中金、银、钯的含量均有很好的准确度和精密度,RSD值均在1.067 % ~ 3.290 %之间,可以满足实际检测的需求。  相似文献   

13.
用HNO_3-HClO_4(4∶1)溶解硒片,电感耦合等离子体原子发射光谱(ICP-AES)法测定其中的硒、铁、钙和锌,实验表明硒片中硒、铁、钙和锌的含量较为丰富,与外包装承诺的含量一致。方法灵敏可靠,测量相对标准偏差3%,加标回收率在96.5%~101%,实验结果为探讨硒片对人体的保健作用提供了参考数据。  相似文献   

14.
ICP-MS测定化肥中有害元素Cr、Cd、As、Pb、Hg的新方法   总被引:6,自引:1,他引:6  
采用电感耦合等离子体质谱法测定化肥中微量Cr、Cd、As、Pb、Hg元素.样品经微波消解和敞开酸溶,滴加5 ~8滴2%高锰酸钾氧化,低温水浴加热蒸至近干,加甲醇2 mL溶剂化,用水定容至100 mL,进行测定.方法标准加入回收率为67% ~115%,RSD小于15%,误差完全符合GB18877-2002的规定要求,方法简便快速.  相似文献   

15.
建立了电感耦合等离子体原子发射光谱(ICP-AES)法测定铁矿石中钒含量的分析方法。采用盐酸、硝酸、氢氟酸、高氯酸分解试样,不溶物残渣碱熔融回收,稀盐酸溶解盐类的方式对样品进行分解。对仪器的主要工作参数和分析谱线进行了选择,讨论了基体和共存元素的干扰,以及溶解酸和熔剂等条件实验,确立了最佳分析条件。按实验方法对铁矿石标准样品和试样中钒量进行测定,测定值与标准值或其它方法的认定值基本一致,相对标准偏差RSD<6.5%。  相似文献   

16.
建立电感耦合等离子体发射光谱法检测面制食品中铝含量的方法。以硝酸-过氧化氢作为消解体系,样品经微波消解后以5%硝酸定容,测定。对仪器条件进行了优化,铝的分析谱线为396.153 nm,射频功率为1 150 W,雾化气流量为0.5 L/min。铝的质量浓度(X)在0.5~10 mg/L范围内与谱线强度(Y)线性良好,工作曲线方程为Y=1 743.2X+58.0,线性相关系数r=0.999 9;测定结果的相对标准偏差小于5%(n=6),加标回收率为92.8%~107.0%。用该方法与标准方法对面食样品进行测定,两种方法测定结果相一致。该方法简便、灵敏、准确,适用于面制食品中铝含量的测定。  相似文献   

17.
通过样品处理、谱线选择、准确度和精密度测定、加标回收实验及与其他测定方法的比对实验,建立了电感耦合等离子体原子发射光谱法(ICP-AES)测定粗锑中As、Bi、Cd 、Cu、Fe、Pb、Se 7种元素的定量分析方法。实验结果表明,该方法准确度高,稳定可靠,相对标准偏差(RSD,n=6)均小于3%,方法的加标回收率在95~105%之间,分析结果与分光光度法、原子吸收光谱法(AAS)及原子荧光光谱法(AFS)分析结果相吻合,能够满足日常对粗锑中杂质元素含量测定的要求。  相似文献   

18.
石墨炉原子吸收光谱法测定转基因棉籽中的铅镉铜铬   总被引:1,自引:0,他引:1  
本文探讨了干法灰化与湿法消解-石墨炉原子吸收光谱法测定转基因与非转基因棉籽中重金属元素铅、镉、铜和铬的方法,比较了两种预处理方法对测定结果的影响.结果表明:两种方法均能满足分析测定的需要.将分析方法应用于转基因与非转基因棉籽中四种重金属含量的测定,结果显示,转基因棉籽中铅和铜的含量明显低于非转基因棉籽,镉和铬的含量与非转基因棉籽相当.  相似文献   

19.
研究了电感耦合等离子体原子发射光谱法(ICP-AES)快速测定铁镍软磁合金中的镍含量,确定了最佳测定条件,以波长221.647nm作为镍的分析线,对溶解酸和酸浓度的影响进行探讨,选择钇作为内标元素。分析试样得到结果的相对标准偏差RSD小于0.91%(n=6),方法回收率为99.8%~100.1%(n=6),分析结果与丁二酮肟分光光度法相一致。电感耦合等离子体原子发射光谱法比传统的化学法准确、快速,已成功用于生产中。  相似文献   