共查询到20条相似文献,搜索用时 574 毫秒
1.
2.
3.
采用两只经过标定的ST401闪烁探测器,测量了脉冲中子管的中子产额,在其中一只探测器前端增加铅板屏蔽,1 cm的铅屏蔽使探测器输出减少了18.20%,在加速器中子源上进行的类似实验表明,0.5 cm的铅使探测器的输出减少了2.90%。对两个中子源上测量的情况进行了蒙特卡罗模拟,加速器实验与模拟符合较好,脉冲中子管实验差别较大。对实验和模拟的情况进行了分析,结果表明:中子管除产生中子外,还会产生数量较多的轫致辐射X射线,这些X射线对准确测量中子管中子产额将造成不良影响。 相似文献
4.
5.
研制了一种新中子探测器,它以235UO2裂变靶作为转换靶,4He气体作为闪烁体.该探测器充分结合了235U和4He两种核素的特点,从而具有中子能量响应平坦、中子灵敏度较高、n/γ分辨本领高等优点,能很好地在混合脉冲裂变辐射场中测量中子.本文对探测器的原理和结构设计进行了介绍,计算了不同能量中子、γ射线在探测器中的能量沉积,并从理论和实验上对探测器的中子灵敏度、γ射线灵敏度、n/γ分辨本领和时间响应进行了研究.结果表明探测器的中子灵敏度约10-15C·cm2,γ灵敏度约10-17C·cm2,时间响应约33.1 ns. 相似文献
6.
7.
8.
9.
依据实验参数,建立了14MeV快中子照相的物理模型,并利用Monte Carlo方法对照相过程进行了模拟. 分析了经聚乙烯样品散射的中子对快中子图像的影响随样品与探测器间距及样品参数的变化. 计算结果表明,样品与探测器的距离d<5cm时,样品中的散射中子对图像的影响强烈依赖于d,而当d>20cm时,样品散射中子对图像的影响可忽略;当样品密度为3—5g/cm3时散射中子对图像的影响相对最大;样品宽度越大,图像中的散射成分越多,当宽度在3cm以上时散射成分的强度趋于饱和.
关键词:
14MeV中子
快中子照相
散射中子
Monte Carlo模拟 相似文献
10.
11.
Xiangpan Ji Ye Xu Junsong Lin Yulong Feng Haolin Li 《Journal of Experimental and Theoretical Physics》2013,117(5):792-799
A direct WIMP (weakly interacting massive particle) detector with a neutron veto system is designed to better reject neutrons. The experimental configuration is studied in this paper involves 984 Ge modules placed inside a reactor-neutrino detector. The neutrino detector is used as a neutron veto device. The neutron background for the experimental design is estimated using the Geant4 simulation. The results show that the neutron background can decrease to O(0.01) events per year per tonne of high-purity germanium and it can be ignored in comparison with electron recoils. 相似文献
12.
为满足中国散裂中子源(CSNS)多功能反射谱仪(MR)主探测器高气压3He多丝正比室探测器(MWPC)的需求,研制了专用的读出电子学系统。该系统主要由核心前放板和触发扇出板构成,其中以前放板为核心,采用了6块前放板实现探测器142路模拟信号的数字化,并通过判选机制甄别中子信息,将有效中子事例打包发送给后端,触发扇出板提供同一时刻到达的T0信号和触发信号,以确保数据的对齐。读出电子学系统分别在实验室和束流条件下,进行了相关指标测试,测试结果表明性能优于设计要求。目前MWPC探测器已经成功安装到MR谱仪现场,并且已经开始稳定运行。 相似文献
13.
14.
A. V. Belushkin A. A. Bogdzel’ A. P. Buzdavin S. I. Veleshki A. I. Zhuravlev V. V. Zhuravlev S. E. Kichanov D. P. Kozlenko S. A. Kulikov F. V. Levchanovskii E. V. Lukin V. M. Milkov S. M. Murashkevich Ts. Ts. Panteleev V. I. Prikhod’ko B. N. Savenko L. T. Tsankov 《Physics of Particles and Nuclei Letters》2013,10(5):436-441
A new gaseous annular sectional thermal-neutron detector for the new neutron diffractometer at the IBR-2 reactor has been designed and manufactured at the Frank Laboratory of Neutron Physics of the Joint Institute for Nuclear Research (JINR). The detector is designed to study small-volume samples at high pressure and consists of 16 sections, each one of which is divided into six independent detector elements. We present the main design features of the detector, detecting electronics, data-acquisition and visualization software, and software system for experiment management. The results of the first neutronographic experiments that were carried out with the use of the detector are also presented. 相似文献
15.
惯性约束中子测温的误差研究 总被引:1,自引:0,他引:1
综合分析了ICF(惯性约束)中子测温系统的误差与其参数的关系,这些参数包括靶核温度,探测的中子数、靶到探测器的距离、探测器的响应函数以及闪烁体厚度等,考虑到中子与探测器的相互作用,探测器的响应与靶的烧蚀过程,在此基础上提出了新的统计误差计算方法,该方法对于改善中子测温的相对误差并应用于闪烁体的设计具有重要意义。 相似文献
16.
TIAN Li-Chao TANG Bin WANG Xiao-Hu LIU Rong-Guang ZHANG Jian CHEN Yuan-Bo SUN Zhi-Jia XU Hong YANG Gui-An ZHANG Qiang 《中国物理C(英文版)》2012,36(6):525-530
China Spallation Neutron Source (CSNS), one project of the 12th Five-Year-Plan scheme of China, is under construction in Guangdong province. Three neutron spectrometers will be installed during the first phase of the project, and two-dimensional position sensitive thermal neutron detectors are required. Before the construction of the neutron detectors, a prototype of a two-dimensional 200 mm×200 mm Multi-wire Proportional Chamber (MWPC) with Ar/CO2 (90/10) flowing gas has been constructed. In 2009, the prototype was tested with the 55Fe X-ray using part of the electronics, and performed well.
Following the test in 2009, the neutron detector was constructed with the complete electronics and filled with the 6 atm. 3He+2.5 atm. C3H8 gas mixture in 2010. The neutron detector has been primarily tested with an Am-Be source. In this paper, new developments of the neutron detector including the design of the high pressure chamber, the optimization of the gas purifying system and the gas filling process will be reported. The results and discussion are also presented in this paper. 相似文献
Following the test in 2009, the neutron detector was constructed with the complete electronics and filled with the 6 atm. 3He+2.5 atm. C3H8 gas mixture in 2010. The neutron detector has been primarily tested with an Am-Be source. In this paper, new developments of the neutron detector including the design of the high pressure chamber, the optimization of the gas purifying system and the gas filling process will be reported. The results and discussion are also presented in this paper. 相似文献
17.
给出了氦冷却固体增殖剂中子学和产氚包层模块(NT-TBM-HCSB)聚变中子诊断的初步设计,提出了用固定或可移动位置微型裂变室探测器和可移动封装薄箔活化分析系统测量中子倍增器之后、固体氚增殖剂中及其后的中子通量;用可移动天然金刚石探测器的紧凑型能谱仪测量中子能谱。此诊断系统可用于中子倍增器的倍增效率,氚增殖层的增殖率与热核实验聚变堆的运行参数、加热和加料方式、磁流体不稳定性、能量约束以及大破裂等离子体参数和状态之间的工程和物理相关关系的实验研究,测量倍增层、氚增殖包层及其后进入屏蔽层的中子通量和能谱,并与MCNP计算相比较,优化和改进中子倍增器、氚增殖包层以及屏蔽层设计,提高氚增殖率。 相似文献
18.
介质型快中子探测器的中子直照响应对其设计和实际应用具有重要影响。利用Geant4编制Monte-Carlo模拟程序对此型探测器的中子直照响应进行了计算。模拟了探测器芯子常用材料在中子入射时带电重粒子的发射情况,发现电荷收集极、卡阈吸收片和后高压绝缘层材料的选择对中子直照响应特性有直接影响。在现有的以聚四氟乙烯为卡阈吸收片和后高压绝缘层材料的探测芯子中,直照响应给总的中子灵敏度带来约6%的贡献。提出了一种使用高电阻率石墨作为卡阈吸收片和后高压绝缘层材料的探测芯子的优化结构,可有效降低中子直照响应。 相似文献
19.
为了在弱中子场和有限小空间内测量绝对裂变率, 制作了俘获探测器, 研究了俘获探测器的性能。 介绍了用于中子测量的俘获探测器和铅屏蔽室, 以及该探测器系统在特定条件下测量裂变反应率的结果, 并与裂变室测量结果进行了比较。 探讨了铅屏蔽室大小对测量结果的影响。 To detect the absolute neutron flux in a weak neutron field and restricted space, the fission fragment trapping detector was fabricated and the properties of the detector were studied. In this paper, the detector and shielding chamber used in neutron detection were described and the experimental measurements of the fission rate in specific condition were performed with the detection system and the result has been compared with that obtained by fission chamber. The influence of the shielding chamber on the measured results was analyzed. 相似文献
20.
V. A. Andreev A. V. Vasiljev E. A. Ivanov D. S. Ilyin A. G. Krivshich A. P. Serebrov 《Technical Physics》2016,61(4):609-617
The gas-discharge detector is designed for the neutron lifetime spectrometer. The detector is intended for ultracold neutron flux monitoring in measurement cycles at the specrtometer (ILL, Grenoble, France). The detector has been successively tested with a Pu–Be neutron source under laboratory conditions and as a part of the spectrometer. 相似文献