首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 24 毫秒
1.
An on-line solid-phase extraction (SPE) protocol using the cigarette filter as sorbent coupled with high-performance liquid chromatography (HPLC) was developed for simultaneous determination of trace naphthalene (NAPH), phenanthrene (PHEN), anthracene (ANT), fluoranthene (FLU), benzo(b)fluoranthene (BbF), benzo(k)fluoranthene (BkF), benzo(a)pyrene (BaP), and benzo(ghi)perylene (BghiP) in water samples. To on-line interface solid-phase extraction to HPLC, a preconcentration column packed with the cigarette filter was used to replace a conventional sample loop on the injector valve of the HPLC for on-line solid-phase extraction. The sample solution was loaded and the analytes were then preconcentrated onto the preconcentration column. The collected analytes were subsequently eluted with a mobile phase of methanol-water (95:5). HPLC with a photodiode array detector was used for their separation and detection. The detection limits (S/N = 3) for preconcentrating 42 mL of sample solution ranged from 0.9 to 58.6 ng L(-1) at a sample throughput of 2 samples h(-1). The enhancement factors were in the range of 409-1710. The developed method was applied to the determination of trace NAPH, PHEN, ANT, FLU, BbF, BkF, BaP and BghiP in local river water samples. The recoveries of PAHs spiked in real water samples ranged from 87 to 115%. The precisions for nine replicate measurements of a standard mixture (NAPH: 4.0 microg L(-1), PHEN: 0.40 microg L(-1), ANT: 0.40 microg L(-1), FLU: 2.0 microg L(-1), BbF: 1.6 microg L(-1), BkF: 2.0 microg L(-1), BaP: 2.0 microg L(-1), BghiP: 1.7 microg L(-1)) were in the range of 1.2-5.1%.  相似文献   

2.
A multi-residue method for the simultaneous extraction from drinking water using solid-phase extraction on LiChrolut EN [poly(styrene-divinylbenzene), PSDVB] and determination of nine N-methylcarbamate pesticides (NMCs) (aldicarb, its metabolites i.e. aldicarb sulfone and aldicarb sulfoxide and carbaryl, carbofuran, dioxacarb, ethiofencarb, methomyl and propoxur) using reversed-phase liquid chromatography was studied. A 1000-fold pre-concentration was achieved and the method was used for determination of the nine pesticides in water, with limits of detection in the range 3-15 ng L(-1). For all compounds the recoveries determined at the 0.1 and 1 microg L(-1) level generally ranged from 85 to 104% with relative standard deviations (RSD) of 1.4-8.8%.  相似文献   

3.
A new method for the determination of polycyclic aromatic hydrocarbons (PAHs) in waste water using solvent-free solid-phase microextraction (SPME) is described. The PAHs are extracted with a 100 microm polydimethylsiloxane (PDMS) fiber, desorbed in 40 microl acetonitrile and measured with LC and fluorescence detection. The detection limits of this very simple method under the given conditions (extraction from 5 ml sample, extraction time 1 h) are in the range of 1-6 ng l(-1). The standard deviations (n = 6) at a concentration level of 0.8 microg l(-1) are between 1.8 and 14.4%. The procedure was used for the determination of PAHs in contaminated water samples.  相似文献   

4.
Multiwalled carbon nanotubes (MWCNTs) were used as a novel kind of solid-phase extraction adsorbents in this work as well as an analytical method based on MWCNTs solid-phase extraction (SPE) combined with high-performance liquid chromatography (HPLC) was established for the determination of polycyclic aromatic hydrocarbons (PAHs), some of which belong to typical persistent organic pollutants (POPs) owing to their carcinogenicity and endocrine disrupting activity. Several conditions that probably affected the extraction efficiency including the eluent volume, sample flow rate, sample pH and the sample volume were optimized in detail. The characteristic data of analytical performance were determined to investigate the sensitivity and precision of the method, and the method was applied to the determination of PAHs in environmental water samples such as river water sample, tap water sample and wastewater sample from the constructed wetland effluent. The experimental results indicated that there were excellent linear relationship between peak area and the concentration of PAHs over the range of 0.04-100 microg L(-1), and the precisions (RSD) were 1.7-4.8% under the optimal conditions. The detection limits of proposed method for the studied PAHs were 0.005-0.058 microg L(-1) (S/N=3). The recoveries of PAHs spiked in environmental water samples ranged from 78.7 to 118.1%. It was concluded that MWCNTs packed cartridge coupled with HPLC was an excellent alternative for the routine analysis of PAHs at trace level.  相似文献   

5.
A method based on solid-phase microextraction (SPME) and gas chromatography with flame ionization detection (GC-FID) has been optimized for the determination of benzene, toluene, ethylbenzene and xylenes (BTEX) in water released from a waste treatment plant. The extraction step was optimized using fractional factorial and central composite designs including the following experimental factors: saline concentration; extraction time; desorption time; agitation velocity; headspace volume. A multiple function was used to describe the experimental conditions for simultaneous extraction of the compounds. The procedure, based on direct SPME at 50 degrees C, using a polydimethylsiloxane fiber, showed good linearity (r>0.997 over a concentration range 2-200 microg L(-1)) and repeatability (relative standard deviation (RSD)<4.23%) for all compounds, with limits of detection ranging from 0.05 to 0.28 microg L(-1), and limits of quantification ranging from 0.14 to 0.84 microg L(-1). Concentrations of the target compounds in these samples were between 145.8 and 1891 microg L(-1).  相似文献   

6.
A multiresidue method was developed and validated to screen bovine urine samples for 10 beta-2-adrenergic agonistic drugs--brombuterol, cimaterol, clenbuterol, clenpenterol, isoxsuprine, mabuterol, ractopamine, ritodrine, salbutamol, and tulobuterol--at the 2 microg/L level. The method is also quantitative in the range of 1 to 4 microg/L for all analytes except salbutamol. The procedure uses enzymatic digestion, liquid-liquid extraction, and cleanup on solid-phase extraction columns, followed by detection using a liquid chromatograph-tandem quadrupole mass spectrometer operated in the positive-ion atmospheric pressure chemical ionization multiple-reaction monitoring mode. Method validation included assessment of recoveries, repeatabilities, linearity of responses, decision limits, and detection capabilities. Overall average recoveries ranged from 70-91%; recoveries were generally lower for salbutamol. The decision limits ranged from 0.4-1.0 microg/L, and detection capabilities from 0.6-1.7 microg/L.  相似文献   

7.
The use of solid-phase extraction for the analysis of liquid media containing low microg/L levels of hexahydro-1,3,5-trinitro-1,3,5-triazine (RDX), mononitroso-RDX (MNX), dinitroso-RDX (DNX), and trinitroso-RDX (TNX) is examined. Aqueous samples (100 mL) consisting of water and a microbiological basal medium are spiked with known concentrations of RDX, MNX, DNX, and TNX. The compounds are extracted from the liquid media using a Porapak RDX cartridge and then eluted from the cartridge with 5 mL of acetonitrile. The eluent is concentrated to 1 mL before analysis by high-pressure liquid chromatography (HPLC). The method detection limits for RDX are 0.1 microg/L in water and 0.5 microg/L in the basal medium after a 100-fold concentration. For MNX, DNX, and TNX, the method detection limits are approximately 0.5 microg/L in water and approximately 1 microg/L in the basal medium after a 100-fold concentration. Interferences in the basal medium and a contaminant in the standard made quantitation for MNX and TNX, respectively, is less accurate below the 1 microg/L level. Solid-phase extraction of the liquid media gave good recoveries of nitramines and nitroso intermediates from a microbiological basal medium, allowing HPLC detection of RDX and the nitroso intermediates in the low microg/L (ppb) range.  相似文献   

8.
A direct solid-phase microextraction (SPME) procedure has been developed and applied for the simultaneous determination of nonylphenol, nonylphenol mono- and diethoxylates and their brominated derivatives in raw and treated water at low microg l(-1) concentrations. Several parameters affecting the SPME procedure, such as extraction mode (headspace or direct-SPME), selection of the SPME coating, extraction time, addition of organic modifiers such as methanol and temperature were optimized. The divinylbenzene-carboxen-polydimethylsiloxane fiber was the most appropriate one for the determination of nonylphenol ethoxylates (NPEOs) and bromononylphenol ethoxylates (BrNPEOs) by SPME-GC-MS. The optimized method was linear over the range studied (0.11-2.5 microg l(-1)) and showed good precision, with RSD values between 4 and 15% and detection limits ranging from 30 to 150 ng l(-1) depending on the compound. The SPME procedure was compared with a solid-phase extraction-GC-MS method (C18 cartridge) for the analysis of NPEO and BrNPEOs in water samples. There was good agreement between the results from both methods but the SPME procedure showed some advantages such as lower detection limits, a shorter analysis time and the avoidance of organic solvents. The optimized SPME method was applied to determine nonylphenol and brominated metabolites in raw and treated water of Barcelona (NE Spain).  相似文献   

9.
A sensitive method for the extraction and determination of polycyclic aromatic hydrocarbons (PAHs) using alcoholic-assisted dispersive liquid-liquid microextraction (AA-DLLME) and HPLC was developed. The extraction procedure was based on alcoholic solvents for both extraction and dispersive solvents. The effective parameters (type and volume of extraction and dispersive solvents, amount of salt and stirring time) on the extraction recovery were studied and optimized utilizing factorial design (FD) and central composite design (CCD). The best recovery was achieved by FD using 2-ethyl-1-hexanol as the extraction solvent and methanol as the dispersive solvent. The results showed that volume of dispersive solvent and stirring time had no effect on the recovery of PAHs. The optimized conditions were 145 μL of 2-ethyl-1-hexanol as the extraction solvent and 4.2% w/v of salt (NaCl) in sample solution. The enrichment factors of PAHs were in the range of 310-325 with limits of detection of 0.002-0.8 ng/mL. The linearity was 0.01-800 ng/mL for different PAHs. The relative standard deviation (RSD) for intra- and inter-day of extraction of PAHs were in the range of 1.7-7.0 and 5.6-7.3, respectively, for five measurements. The method was also successfully applied for the determination of PAHs in environmental water samples.  相似文献   

10.
Zhou Y  Xu D  Chen D  Zhang Z  Zheng X  Fang E 《色谱》2011,29(7):656-661
基于固相微萃取-气相色谱(SPME-GC)建立了检测茶叶中氟虫腈及其代谢物(脱亚硫酰基氟虫腈、硫化氟虫腈、氟虫腈砜、酰胺氟虫腈)残留的分析方法。实验中采用85 μm聚丙烯酸酯(PA)萃取头,萃取温度为60 ℃,萃取缓冲体系的pH值为9。当添加水平为2~10 μg/kg时,回收率在71.2%~109.3%之间,相对标准偏差(RSD)在1.2%~7.1%之间。方法的检出限(LOD)和定量限(LOQ)分别在0.3~1.2 μg/kg和1.0~4.0 μg/kg之间。对所建立的方法采用气相色谱-质谱(GC-MS)进行确证,结果令人满意。本方法灵敏度、精密度和LOD均符合残留分析要求,具有快速、灵敏度高的特点,适合于茶叶中氟虫腈及其代谢物残留的痕量分析。  相似文献   

11.
Huo SH  Yan XP 《The Analyst》2012,137(15):3445-3451
The unusual properties such as high surface area, good thermal stability, uniform structured nanoscale cavities and the availability of in-pore functionality and outer-surface modification make metal-organic frameworks (MOFs) attractive for diverse analytical applications. However, integration of MOFs with magnets for magnetic solid-phase extraction for analytical application has not been attempted so far. Here we show a facile magnetization of MOF MIL-101(Cr) for rapid magnetic solid-phase extraction of polycyclic aromatic hydrocarbons (PAHs) from environmental water samples. MIL-101 is attractive as a sorbent for solid-phase extraction of pollutants in aqueous solution due to its high surface area, large pores, accessible coordinative unsaturated sites, and excellent chemical and solvent stability. In situ magnetization of MIL-101 microcrystals as well as magnetic solid-phase extraction of PAHs was achieved simultaneously by simply mixing MIL-101 and silica-coated Fe(3)O(4) microparticles in a sample solution under sonication. Such MOF-based magnetic solid-phase extraction in combination with high-performance liquid chromatography gave the detection limits of 2.8-27.2 ng L(-1) and quantitation limits of 6.3-87.7 ng L(-1) for the PAHs. The relative standard deviations for intra- and inter-day analyses were in the range of 3.1-8.7% and 6.1-8.5%, respectively. The results showed that hydrophobic and π-π interactions between the PAHs and the framework terephthalic acid molecules, and the π-complexation between PAHs and the Lewis acid sites in the pores of MIL-101 play a significant role in the adsorption of PAHs.  相似文献   

12.
建立了同时测定牛奶中残留的9种磺胺类药物的固相萃取-高效液相色谱分析方法。牛奶样品经磷酸盐缓冲液稀释后高速离心去除脂肪,过C18小柱,用水淋洗,甲醇洗脱,洗脱液经氮气吹干后用乙酸乙酯溶解,并过氨基固相萃取小柱净化,用正己烷及水淋洗,以甲醇-乙腈-水(含1%乙酸)(体积比为1∶1∶8)洗脱,洗脱液用于高效液相色谱分析。采用Inertsil ODS-3 C18柱分离,以水-乙酸和甲醇-乙腈为流动相进行梯度洗脱,二极管阵列检测器检测,外标法定量。9种磺胺类药物标准曲线的线性回归系数均在 0.9999 以上,线性范围为25~5000 μg/L,检出限为1.7~2.8 μg/L,定量限为5.7~9.2 μg/L。在10,20,40 μg/L 添加水平下的添加回收率为72.1%~88.3%,相对标准偏差为2.3%~5.0%。该方法具有快速、灵敏的特点,符合现行兽药残留分析的要求。  相似文献   

13.
Xie SM  Zhang M  Wang ZY  Yuan LM 《The Analyst》2011,136(19):3988-3996
Solid-phase extraction (SPE) is one of the most important techniques for sample preparation, purification, concentration and cleanup. Membranes made from synthetic organic polymers, cellulose, or glass fibers are used for sample pretreatment. In this work, we report that a porous metal membrane, the metal filter in HPLC, was used as a novel kind of solid-phase extraction adsorbent material. To evaluate the performance of the porous metal membrane for the SPE, naphthalene, fluorene, anthracene, phenanthrene, fluoranthene, pyrene, chrysene, perylene and benzo(a)pyrene were selected as analytes. Several parameters that affected the extraction efficiency such as the extraction time, the concentration of NaCl, the extraction temperature and the agitation speed were optimized. The experimental result indicates that the porous metal membrane possesses high adsorption ability to the tested polycyclic aromatic hydrocarbons (PAHs). Under the optimum conditions, the detection limits of the developed method were in the range of 0.03-0.082 μg L(-1) (S/N = 5), and excellent linear correlations between peak area and concentration of PAHs were found over the range of 0.1-60 μg L(-1). The precisions (RSD) for five replicate extractions of the PAHs from sample solutions were in the range of 2.6-5.0%. The recoveries of the PAHs from tap water and river water samples spiked with 9 PAHs (20 μg L(-1) of each individual PAH) ranged from 83.0% to 112.5%. The porous metal membrane is durable, simple, inexpensive, reproducible and has a high adsorption ability for use in SPE of PAHs.  相似文献   

14.
Zhu B  Chen H  Li S 《色谱》2012,30(2):201-206
以密度小于水的轻质溶剂为萃取剂,建立了无需离心步骤的溶剂去乳化分散液-液微萃取-气相色谱(SD-DLLME-GC)测定水样中多环芳烃的新方法。传统分散液-液微萃取技术一般采用密度大于水的有机溶剂为萃取剂,并需要通过离心步骤促进分相。而本方法以密度比水小的轻质溶剂甲苯为萃取剂,将其与丙酮(分散剂)混合并快速注入水样,获得雾化体系;然后注入乙腈作为去乳化剂,破坏该雾化体系,无需离心,溶液立即澄清、分相;取上层有机相(甲苯)进行GC分析。考察了萃取剂、分散剂、去乳化剂的种类及其体积等因素对萃取率的影响。以40 μL甲苯为萃取剂,500 μL丙酮为分散剂,800 μL乙腈为去乳化剂,方法在20~500 μg/L范围内呈现出良好的线性(r2=0.9942~0.9999),多环芳烃的检出限(S/N=3)为0.52~5.11 μg/L。用所建立的方法平行测定5份质量浓度为40 μg/L的多环芳烃标准水样,其含量的相对标准偏差为2.2%~13.6%。本法已成功用于实际水样中多环芳烃的分析,并测得其加标回收率为80.2%~115.1%。  相似文献   

15.
The solid-phase microextraction (SPME) technique using a 75 mm film of carboxen/polydimethylsiloxane was applied to the analysis of chloroacetanilide herbicides (acetochlor, alachlor, butachlor, metolachlor, and propachlor) residues. The feasibility of SPME with gas chromatography electron capture detection analysis has been evaluated. The effects of experimental parameters such as magnetic stirring, salt addition, humic acid addition, pH value, and extraction time, as well as desorption temperature and time, were investigated. Analytical parameters such as linearity, repeatability and limit of detection were also evaluated. The inhibition of humic acid to the extraction of chloroacetanilide herbicides was observed. A standard addition method for calibration was recommended to reduce deviations caused by matrix interferences. The proposed method provided a simple and rapid analytical procedure for chloroacetanilide herbicides in water with limits of detection 0.002-0.065 microg/L for deionized water, and 0.005-0.22 microg/L for farm water. The relative standard deviations (n = 5) for analyses of farm water were 7-20% for 5 [corrected] microg/L chloroacetanilide herbicides. This application was illustrated by the analysis of sample collected from farm water in the Chung-hwa area, Taiwan.  相似文献   

16.
A solid-phase extraction (SPE) method using triacontyl bonded silica (C30) as sorbent was developed for the determination of 16 US Environmental Protection Agency polycyclic aromatic hydrocarbons (PAHs) in airborne particulate matters quantitatively by gas chromatography-mass spectrometry (GC-MS). Optimization experiments were conducted using spiked standard aqueous solution of PAHs and real airborne particulates samples aiming to obtain highest SPE recoveries and extraction efficiency. Factors were studied in SPE procedures including the concentration of organic modifier, flow rate of sample loading and elution solvents. The ultrasonication time and solvents were also investigated. Recoveries were in the range of 68-107% for standard PAHs aqueous solution and 61-116% for real spiked sample. Limits of detection (LODs) and limits of quantification (LOQs) with standard solution were in the range of 0.0070-0.21 microgL(-1) and 0.022-0.67 microgL(-1), respectively. The optimized method was successfully applied to the determination of 16 PAHs in real airborne particulate matters.  相似文献   

17.
Gas chromatography with electron capture detection (GC-ECD) is a highly explosive-sensitive analytical technique. However, its application to the analysis of sediment extracts is hampered by the presence of numerous endogenous interferences. In the present study, solid-phase microextraction (SPME) was used both as a purification technique for sediment extracts and as an extraction technique for water samples prior to analysis by GC-ECD. SPME/GC-ECD coupling was optimized and applied to the trace analysis of nine explosives including nitroaromatics and RDX in real seawater and marine sediment samples. Addition of a high concentration of salt (30%, w/v) in the aqueous medium and use of a carbowax/divinylbenzene (CW/DVB) coating led to optimal extraction efficiencies. Method detection limits (MDLs) ranged from 0.05 to 0.81 microg/L in water and from 1 to 9 microg/kg in dry sediment. Except for RDX, spike recoveries in seawater were satisfactory (89-147%) when samples were fortified at 2 microg/L of each analyte. Spike recoveries from dry sediment fortified at 10 microg/kg of each analyte gave lower recoveries but these could also be due to degradation in the matrix. With a smaller volume of aqueous sample required compared to solid-phase extraction (SPE), SPME is an attractive method for the analysis of limited volumes of sediment pore-water. Moreover, the use of SPME eliminated interferences present in sediment extracts thus allowing the detection of the target analytes that were otherwise difficult to detect by direct injection.  相似文献   

18.
Linear alkylbenzene sulfonates (LAS) have been determined in samples of the influent and the effluent, and in the sludge, from sewage-treatment plants (STP). LAS and sulfophenyl carboxylate compounds (SPC) were isolated by solid-phase extraction (SPE) with the polymeric phase Isolute ENV, then determined by liquid chromatography-electrospray mass spectrometry (LC-ESI-MS). The method enabled unequivocal identification of C10-C13 LAS by monitoring the ion at m/z 183 and the base peak corresponding to the [M-H]- ion. Average recoveries varied from 77-93% and the linear range of the method varied from 0.2 to 10 microg L(-1), with a limit of detection ranging from 10 ng L(-1) to 1.5 microg L(-1) when 200 mL waste water were preconcentrated. For sewage sludge, recoveries varied from 58 to 90% and the linear range was between 0.2 and 100 microg L(-1), with a detection limit ranging from 0.4 to 120 microg kg(-1) when 2.5 g sewage sludge was extracted. Unequivocal identification and determination of some metabolites of the LAS, the sulfophenyl carboxylate compounds (SPC), was achieved by monitoring [M-H]- ions.  相似文献   

19.
The aim of this study was to develop a methodology for the analysis of the insecticide fenitrothion and its two main environmental metabolites, fenitrooxon and 3-methyl-4-nitrophenol. For this purpose, a solid-phase microextraction (SPME) method coupled to high performance liquid chromatography (LC) was optimized. Two on-line detectors, diode array (DAD) and direct current amperometrical (DCAD) were used in order to determine sensitivity and selectivity. The effects of the extraction parameters, including exposure and desorption time, pH, temperature, salt concentration and desorption mode on the extraction efficiency were studied. A satisfactory reproducibility for extractions from samples at 20 ppb-level with RSD < 12.5% (n = 10) was obtained. The calibration graphs were linear in the range of 10-1000 microg l(-1) and detection limits for the target compounds were between 1.2 and 11.8 microg l(-1) depending on which detector was used. The method was applied for determining fenitrothion and both its metabolites in river waters which run through forest areas near to aerial application of the pesticide.  相似文献   

20.
高效液相色谱-串联质谱法测定蜂蜜中9种农药残留   总被引:2,自引:0,他引:2  
建立了同时测定蜂蜜中9种苯并咪唑类和新烟碱类农药的全自动固相萃取-高效液相色谱-串联质谱检测方法。蜂蜜样品用磷酸盐缓冲液(pH=7.8)溶解,超声提取,经亲水亲脂平衡(hydrophilic-lipophilic balance,HLB)固相萃取小柱净化,氮吹浓缩,定容,过滤膜后进行高效液相色谱-串联质谱分析,采用多反应监测(MRM)模式测定,以内标法定量。结果表明,在0.002~0.05 mg/L范围内9种农药呈现出较好的线性关系(相关系数r2 ≥ 0.99),检出限和定量限分别为0.1~1.0 μg/kg和0.3~2.0 μg/kg。对阴性蜂蜜,在5.0、10.0、20.0 μg/kg 3个水平下分别进行加标回收试验,测出9种农药的平均回收率在78.2%~101.2%之间,相对标准偏差为1.3%~14.3%(n=6)。该方法可适用于大批量蜂蜜样品的快速准确测定。  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号