Manual solid-phase microextraction (SPME) coupled with gas chromatography-mass spectrometry (GC-MS) is applied for the determination of polycyclic aromatic hydrocarbons (PAHs) from natural matrix through a distilled water medium. Seven of the 16 PAH standards (naphthalene, acenaphthene, fluorene, anthracene, fluoranthene, pyrene, benzo[a]anthracene) are spiked on a marine muddy sediment. The samples, containing PAHs in the range of 10-20 ppm, are then aged at room temperature more than 10 days before analysis. The influence of the matrix, SPME adsorption time, pH, salt content, and SPME adsorption temperature are investigated. The reproducibility of the technique is less than 13% (RDS) for the first 6 considered PAHs and 28% (RDS) for benzo(a)anthracene with a fiber containing a 100-micron poly dimethylsiloxane coating. Linearity extended in the range of 5-50 picograms for PAHs direct injection, 5-70 picograms for PAHs in water, and 1-170 picograms for PAHs in sediment. The detection limit is estimated less than 1 microgram/kg of dry sample for the first 6 considered PAHs in sediment and 1.5 micrograms/kg of dry sample for benzo(a)anthracene using the selected ion monitoring mode in GC-MS. The recoveries of the considered PAHs are evaluated.  相似文献   

2.
A solid-phase microextraction (SPME)-gas chromatography (GC)-mass spectrometry (MS) analytical method for the simultaneous separation and determination of 16 polycyclic aromatic hydrocarbons (PAHs) from aqueous samples has been developed, based on the sorption of target analytes on a selectively sorptive fibre and subsequent desorption of analytes directly into GC-MS. The influence of various parameters on PAH extraction efficiency by SPME was thoroughly studied. Results show that the fibre exposure time and the use of agitation during exposure are critical in enhancing SPME performance. The presence of colloidal organic matter (as simulated by humic acid) in water samples is shown to significantly reduce the extraction efficiency, suggesting that SPME primarily extracts the truly dissolved compounds. This offers the significant advantage of allowing the differentiation between freely available dissolved compounds and those associated with humic material and potentially biologically unavailable. The method showed good linearity up to 10 μg/l. The reproducibility of the measurements expressed as relative standard deviation (R.S.D.) was generally <20%. The method developed was then applied to extract PAHs from sediment porewater samples collected from the Mersey Estuary, UK. Total PAH concentrations in porewater were found to vary between 95 and 742 ng/l with two to four ring PAHs predominating. Results suggest that SPME has the potential to accurately determine the dissolved concentrations of PAHs in sediment porewater.  相似文献   

3.
A method for the determination of 16 polycyclic aromatic hydrocarbons (PAHs) in milk and related products based on direct immersion-solid phase microextraction (DI-SPME) followed by gas chromatography-mass spectrometry detection (GC-MS) has been developed. The influence of various parameters on PAH extraction efficiency was carefully monitored. Good performance (recovery, precision and quantitation limits) was attained when a PDMS/DVB fiber was immersed in the sample for 60 min at 55 °C. Detection limits ranged from 0.003 to 1.5 μg L−1 at a signal-to-noise ratio of 3, depending on the compound and the sample. The proposed method was successfully applied to infant formulas, milk and related products and the presence of both fluoranthene and pyrene in two samples was confirmed.  相似文献   

4.
The possibility of quantitative analysis of aromatic hydrocarbons in oil-based asphalt release agents was investigated using headspace solid-phase microextraction (HS-SPME) followed by gas chromatography-mass spectrometry (GC-MS). The target analytes studied were benzene, toluene, ethylbenzene, p-, m-, and o-xylene (BTEX) and 1,3,5-trimethylbenzene and 1,2,4-trimethylbenzene. Experimental parameters influencing HS-SPME efficiency were studied (equilibration time between sample and headspace and between headspace and SPME fiber, sample amount and sample matrice effects). A HS-SPME method using hexadecane as a surrogate matrice was developed. The detection limit was estimated as 0.03-0.08 ppm (w/w) for the target analytes investigated. Good linearity was observed (R2 > 0.999) for all calibration curves at high, medium and low concentration level. The repeatability of the method (RSD, relative standard deviation) was found to be less than 10% (generally less than 5%) in triplicate samples and approximately 2% at eight consecutive tests on one and the same sample. The accuracy of the method given by recovery of spiked samples was between 85 and 106% (generally between 95 and 105%). The HS-SPME method developed was applied to four commercially available asphalt release agents. External calibration and standard addition approaches were investigated regarding accuracy. The results showed that standard addition generates higher accuracy than external calibration. The contents of target aromatic hydrocarbons in the asphalt release agents studied varied greatly from approximately 0.1-700 ppm. The method described looks promising, and could be a valuable tool for determination of aromatic hydrocarbons in different types of organic matrices.  相似文献   

5.
Zheng L  Chen H  Chen J  Feng Z  Gao S  Zhou J 《色谱》2011,29(12):1173-1178
建立了一种简单、准确的测定热塑性弹性体中16种多环芳烃(PAHs)的气相色谱-质谱(GC-MS)方法。考察了样品制备、萃取溶剂、萃取方法、时间以及温度对厂家制备的阳性热塑性弹性体样品中PAHs提取效率的影响,确定了萃取条件和方法。样品经甲苯超声萃取、浓缩后用环己烷溶解、二甲亚砜液液萃取净化后采用GC-MS进行分析,内标法定量。通过对不同材质阳性热塑性弹性体样品的加标回收、精密度试验等对建立的方法进行评价,16种PAHs的平均回收率为70%~117%,精密度为0.2%~10.8%。该方法适合于热塑性弹性体中PAHs的测定。  相似文献   

6.
气相色谱质谱法测定化妆品中9种多环芳烃   总被引:1,自引:0,他引:1  
建立了气相色谱质谱法测定化妆品中9种多环芳烃的分析方法。化妆品中的萘、苯并[a]蒽、、苯并[b]荧蒽、苯并[j]荧蒽、苯并[k]荧蒽、苯并[e]芘、苯并[a]芘、二苯并[a,h]蒽等9种多环芳烃用甲醇超声提取后,用环己烷液-液萃取后浓缩,经硅胶-中性氧化铝柱净化后,采用气相色谱-质谱测定。多环芳烃浓度在0.05~2 mg/L范围内,质量浓度与其峰面积呈良好的线性关系。在低、中、高3个添加水平下,9种多环芳烃化合物的平均回收率为81.6%~100.2%,相对标准偏差为1.3%~5.8%。方法可用于化妆品中多环芳烃的检测。  相似文献   

7.
An ultrasound-assisted emulsification-microextraction (USAEME) procedure was developed for the extraction of US EPA 16 polycyclic aromatic hydrocarbons (PAHs) in 10 mL of water samples, with subsequent determination by gas chromatography-mass spectrometry (GC-MS). After determination of the most suitable solvent and solvent volume, several other parameters (i.e., extraction time, centrifugation time and ionic strength of the sample) were optimized using a 23 factorial experimental design. Limits of detection ranged from 0.001 to 0.036 μg L−1. The developed procedure was applied to fortified distilled water with different fortification levels (0.5, 2 and 5 μg L−1). Recoveries were over 92% and relative standard deviations of the recoveries were below 8%. The efficiency of the USAEME was compared with traditional liquid-liquid extraction (LLE) and solid-phase extraction on real water samples (i.e., tap water, well water and surface (lake) water as well as domestic and industrial wastewaters). The USAEME showed comparable efficiencies especially with LLE. The developed USAEME was demonstrated to be robust, viable, simple, rapid and easy to use for the determination of PAHs in water samples by GC-MS.  相似文献   

8.
A new and completely automated method for the determination of ten relevant polycyclic aromatic hydrocarbons (PAHs) in olive oil is proposed using an extraction by the headspace (HS) technique. Quantification and confirmation steps are carried out by gas chromatography-mass spectrometry (GC-MS) combining simultaneously selected-ion monitoring (SIM) and tandem mass spectrometry (MS/MS). This combination offers on one hand an increased sensitivity and on the other hand, selective and reliable qualitative information. Sample pretreatment or clean-up are not necessary because the olive oil sample is put directly into an HS vial, automatically processed by HS and introduced into the GC-MS instrument for analysis. Because of its high selectivity and sensitivity, a triple-quadrupole (QqQ) detector coupled with the gas chromatograph allows us to limit handling. Each sample is completely processed in approximately 63 min (45 min for HS isolation and 18 min for GC-MS determination), a reduced time compared with previously published methods. The chemical and instrumental variables were preliminarily optimized using uncontaminated olive oil samples spiked with 25 microg kg(-1) of each target compound. The final method was validated to ensure the quality of the results. The precision was satisfactory, with relative standard deviation (RSD) values in the range 3-9%. Recovery rates ranged from 96 to 99%. Limits of detection (LOD) were calculated as 0.02-0.06 microg kg(-1) and the limits of quantification (LOQ) were obtained as 0.07-0.26 microg kg(-1). It must be mentioned that the LOD and LOQ are much lower than the maximum levels established by the European Union (EU) in oils and fats intended for direct human consumption or for use as an ingredient in foods, which are set at 2 microg kg(-1). All the figures of merit are completely in accordance with the latest EU legislation. This fact makes it possible to consider the proposed method as a useful tool for the control of PAHs in olive oils.  相似文献   

9.
This paper describes a rapid and solvent-free method, microwave-assisted headspace solid-phase microextraction (MA-HS-SPME), for the extraction of six commonly used synthetic polycyclic musks: galaxolide (HHCB), tonalide (AHTN), celestolide (ADBI), traseolide (ATII), cashmeran (DPMI) and phantolide (AHMI) from water samples prior to their determination using gas chromatography-mass spectrometry (GC-MS). The effects of various extraction parameters for the quantitative extraction of these analytes by MA-HS-SPME were systematically investigated and optimized. The analytes in a 20-mL water sample (in a 40-mL sample-vial containing 4 g of NaCl) were efficiently extracted by a polydimethylsiloxane-divinylbenzene (PDMS-DVB) fiber placed in the headspace when the system was microwave irradiated at 180 W for less than 4 min. The limits of detection (LODs) ranged from 0.05 to 0.1 ng/L, and the limits of quantification (LOQs) were less than 0.2 ng/L. A preliminary analysis of wastewater samples revealed that HHCB and AHTN were the two most commonly detected synthetic polycyclic musks; using a standard addition method, their concentration were determined to range from 1.2 to 37.3 ng/L with relative standard deviation (RSD) ranging from 2 to 6%. The results obtained using this approach are better than those from the conventional oil-bath HS-SPME.  相似文献   

10.
A method for the determination of trace amounts of the insecticide fipronil was developed using solid-phase microextraction-gas chromatography-mass spectrometry and selected ion monitoring. Fipronil was extracted with a fused-silica fiber coated with 85 microm polyacrylate. The effects of pH, ionic strength, sample volume, extraction and desorption times as well as the extraction temperature were studied. Lindane was used as an internal standard. The linear concentration range of application was 0.3-100 ng ml(-1) of fipronil, with a relative standard deviation of 9.5% (for a level of 50 ng ml(-1)) and a detection limit of 0.08 ng ml(-1). The method was applied to check the eventual existence of fipronil above this limit in water and soil samples from Granada (Spain) as well as in human urine samples. The method validation was completed with spiked matrix samples. The method can be applied as a monitoring tool for water, soil and urine, in the investigation of environmental and occupational exposure to fipronil.  相似文献   

11.
12.
An accurate and reliable method for determining polycyclic aromatic hydrocarbons (PAHs) in atmospheric aerosols is described. This optimised gas chromatography-mass spectrometry (GC-MS) method permits a wide range of concentrations to be analysed without the influence of interferences.Pre-treatment comparison of four kinds of aerosol collector filters determined that quartz and glass fibre filters were the most suitable. Solvents like cyclohexane, toluene, acetonitrile and dichloromethane were evaluated for their PAH-extraction capacity. Ultrasonic extraction using CH2Cl2 was selected because it is rapid and easy; moreover, this solvent increases the sample-throughput capacity.PAH compounds were quantitatively collected and ultrasonically extracted twice using 15 mL of CH2Cl2 for 15 min for each replicate. Rotavapor concentration, fractionation and dissolution were also optimised.A certified standard mixture (16 EPA PAHs), a deuterated compound and precision recovery assays were used for validating the proposed methodology. Adequate analytical parameters were obtained. Detection limits were (1.6-26.3) × 10−5 ng and quantification limits were (5.2-87.6) × 10−5 ng.Analysis of the environmental samples detected 4-10 EPA list PAH compounds. In addition, 2-11 tentative compounds were found, and their molecular structures were described for the first time.Our study of both Youden method and the standard addition method has shown that the proposed determination of PAHs in environmental samples is free of systematic errors.In conclusion, this unbiased methodology improves the identification and quantification of PAH compounds. High sensitivity as well as acceptable detection and quantification limits were obtained for the environmental applications.  相似文献   

13.
Summary A method for determination of trace amounts of the pesticides tebufenpyrad and oxadiazon, previous solid-phase microextraction (SPME), was developed using gas chromatographymass spectrometry and selected ion monitoring (GC-MS; SIM). Both pesticides were extracted with a fused silica fiber coated with 100 μm polydimethylsiloxane. The effects of pH ionic strength, sample volume, extraction and desorption times as well as extraction temperature were studied. The linear concentration range of application was 0.5–250 ng mL−1 for both compounds, with a detection limit of 0.06 ng mL−1 for tebufenpyrad and 0.02 ng mL−1 for oxadiazon. SPME-GC-MS analysis yielded good reproducibility (RSD between 7.5–10.1%). It was used to check the eventual existence of tebufenpyrad and oxadiazon above this limit in water and soil samples from Granada (Spain) as well as in human urine samples. The method validation was completed with spiked matrix samples. It can be applied as a monitoring tool for water, soil and urine in the investigation of environmental and occupational exposure to tebufenpyrad and oxadiazon.  相似文献   

14.
A method for the determination of trace amounts of the herbicide oxadiazon was developed using headspace solid-phase microextraction (HS-SPME), gas chromatography-mass spectrometry (GC-MS) and selected ion monitoring. It was applied to determine oxadiazon in ground water, agricultural soil, must, wine and human urine samples. To determine oxadiazon in liquid samples, a response surface methodology generated with a Doehlert design was applied to optimize the HS-SPME conditions using a 100 microm polydimethylsiloxane fibre. For the analysis of soil samples, they were mixed with water and the SPME fibre suspended in the headspace above the slurry. Ground water, human urine and must show linear concentration range of application of 0.5-50 ng ml(-1)' with detection limits < or =0.02 ng ml(-1). HS-SPME-GC-MS analysis yielded good reproducibility (RSD values between 6.5 and 13.5%). The method validation was completed with spiked matrix samples. The developed analytical procedure is solvent free, cost effective and fast.  相似文献   

15.
This study describes the determination of polycyclic aromatic hydrocarbons (PAHs) in water using high-performance liquid chromatography (HPLC) coupled with fluorescence detection (FLD). Because individual PAHs are generally present in water only at trace levels, a sensitive and accurate determination technique is essential. The separation and detection of five PAHs were run completely within 25 min by the HPLC/FLD system with an analytical C18 column, a fluorescence detection, and acetonitrile-water gradient elution. Calibration graphs were linear with very good correlation coefficients (r > 0.9998), and the detection limits were in the range of 2-6 ng/l for five PAHs. Solid phase microextraction (SPME) was performed for sample pretreatment prior to HPLC-FLD determination, and the governing parameters were investigated. Compared to conventional methods, SPME has high recovery, saves considerable time, and reduces solvents waste. The extraction efficiencies of five PAHs were above 88% and the extraction times were 35 min in one pretreatment procedure. One particular discovery is that 1.5 M sodium monochloroactate (ClCH2COONa) can improve the extraction yield of PAH compounds more than other inorganic salts. The SPME-HPLC-FLD technique provides a relatively simple, convenient, practical procedure, which was here successfully applied to determine five PAHs in water from authentic water samples.  相似文献   

16.
A solid-phase microextraction (SPME) and gas chromatography-mass spectrometry method for determining polycyclic aromatic hydrocarbons (PAHs) in environmental solid matrices is developed. Investigated matrices include seaweed (Undaria pinnatifida and Himanthalia elongata), humic substances (isolated from a wetland out-flow and purchased from Aldrich), and soil. Optimal conditions for a good SPME efficiency of 16 hydrocarbon compounds are obtained using a 100- micro m polydimethylsiloxane fiber directly immersed in aqueous carrier medium. The method is remarkable for presenting short extraction times and considerably high sensitivities. The SPME results obtained by using internal calibration give the total analyte concentration based on the identical partitioning behavior of native and spiked pollutants. The detection limits range from 0.001 to 0.1 mg of PAH per kilogram of dry matrix. SPME external calibration provides information regarding freely dissolved analytes. The detection limits range from 0.001 to 0.05 micro g of PAH per liter of carrier medium. The SPME with external calibration procedure can be applied to measure free concentrations of a target compound spiked into a carrier medium and onto a matrix. Based on a comparison of results obtained for the two samples, the partitioning of the target analyte between the matrix and the carrier medium is calculated.  相似文献   

17.
Manual solid-phase microextraction (SPME) coupled with gas chromatography-mass spectrometry is investigated as a possible alternative for the determination of petroleum hydrocarbons in soils. Spiked onto an agricultural soil is a commercial diesel fuel (DF) with the following composition by weight: 12% linear alkanes, 52% saturated hydrocarbons (branched and cyclic), 21% alkylated aromatic hydrocarbons, 6% polycyclic aromatic hydrocarbons, and 9% unidentified compounds. The spiked soil samples are aged three days at room temperature before analysis. The optimal conditions for the SPME of DF from soils are examined and maximum sensitivity is obtained using a 100-microm polydimethylsiloxane fiber at a sampling temperature of 47 degrees C by sonication both in the headspace and directly through a water medium. The reproducibility of the whole technique showed a relative standard deviation of 10%. The parameters that can influence the recovery of DF (such as the time of SPME extraction, the presence of organic solvent and water, and the matrix) are investigated. The linearity is verified in the range of 40 to 1200 mg/L for the direct injection of DF, 0.1 to 1 mg/L for the SPME of DF from water, and 1 to 50 mg/Kg of dry soil for the SPME of DF from soils. The detection limits are respectively 0.5 mg/L, 0.02 mg/L, and 0.1 mg/Kg of dry soil. The method is corroborated by comparing the results with those obtained by the traditional way.  相似文献   

18.
Zhou Y  Xu D  Chen D  Zhang Z  Zheng X  Fang E 《色谱》2011,29(7):656-661
基于固相微萃取-气相色谱(SPME-GC)建立了检测茶叶中氟虫腈及其代谢物(脱亚硫酰基氟虫腈、硫化氟虫腈、氟虫腈砜、酰胺氟虫腈)残留的分析方法。实验中采用85 μm聚丙烯酸酯(PA)萃取头,萃取温度为60 ℃,萃取缓冲体系的pH值为9。当添加水平为2~10 μg/kg时,回收率在71.2%~109.3%之间,相对标准偏差(RSD)在1.2%~7.1%之间。方法的检出限(LOD)和定量限(LOQ)分别在0.3~1.2 μg/kg和1.0~4.0 μg/kg之间。对所建立的方法采用气相色谱-质谱(GC-MS)进行确证,结果令人满意。本方法灵敏度、精密度和LOD均符合残留分析要求,具有快速、灵敏度高的特点,适合于茶叶中氟虫腈及其代谢物残留的痕量分析。  相似文献   

19.
A fiber coating from polyaniline (PANI) was electrochemically prepared and employed for solid phase microextraction (SPME) of some polycyclic aromatic hydrocarbons (PAHs) from water samples. The PANI film was directly electrodeposited on the platinum wire surface in sulfuric acid solution using cyclic voltammetry (CV) technique. The applicability of this coating was assessed employing a laboratory-made SPME device and gas chromatography with mass spectrometry (GC-MS) for the extraction of some PAHs from the headspace of aqueous samples. Application of wider potential range in CV led to a PANI with more stability against the temperature. The homogeneity and the porous surface structure of the film were examined by the scanning electron microscopy (SEM). The study revealed that this polymer is a suitable SPME fiber coating for extracting the selected PAHs. Important parameters influencing the extraction process were optimized and an extraction time of 40 min at 40 degrees C gave maximum peak area, when the aqueous sample was added with NaCl (20%, w/v). The synthesis of the PANI can be carried out conveniently and in a reproducible manner while it is rather inexpensive and stable against most of organic solvents. The film thickness of PANI can be precisely controlled by the number of CV cycles. The resulting thickness was roughly 20 microm after 20 cycles. At the optimum conditions, the relative standard deviation (RSD) for a double distilled water spiked with selected PAHs at ppb level were 8.80-16.8% (n = 3) and detection limits for the studied compounds were between 0.1-6 pg mL(-1). The performance of PANI was, also, compared with a commercial solid coated-based SPME fiber, carbowax/divinylbenzene (CW/DVB), under similar experimental conditions.  相似文献   