首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 32 毫秒
1.
《Electroanalysis》2005,17(17):1529-1533
The direct electrochemical oxidation of ascorbic acid at an edge plane pyrolytic graphite electrode (EPPG) is investigated and compared with other common carbon‐based electrodes, specifically glassy carbon, boron doped diamond and basal plane pyrolytic graphite. It is found that the EPPG electrode shows a significantly higher degree of electrochemical reversibility than the other electrode substrates giving rise to an analytically optimized limit of detection and sensitivity of 7.1×10?5 M and 0.065 A M?1 respectively.  相似文献   

2.
Antimony is an element of significant environmental concern, yet has been neglected relative to other heavy metals in electroanalysis. As such very little research has been reported on the electroanalytical determination of antimony at unmodified carbon electrodes. In this paper we report the electrochemical determination of Sb(III) in HCl solutions using unmodified carbon substrates, with focus on non-classical carbon materials namely edge plane pyrolytic graphite (EPPG), boron doped diamond (BDD) and screen-printed electrodes (SPE). Using differential pulse anodic stripping voltammetry, EPPG was found to give a considerably greater response towards antimony than other unmodified carbon electrodes, allowing highly linear ranges in nanomolar concentrations and a detection limit of 3.9?nM in 0.25?M HCl. Furthermore, the sensitivity of the response from EPPG was 100 times greater than for glassy carbon (GC). Unmodified GC gave a comparable response to previous results using the bare substrate, and BDD gave an improved, yet still very high limit of detection of 320?nM compared to previous analysis using an iridium oxide modified BDD electrode. SPEs gave a very poor response to antimony, even at high concentrations, observing no linearity from standard additions, as well as a major interference from the ink intrinsic to the working electrode carbon material. Owing to its superior performance relative to other carbon electrodes, the EPPG electrode was subjected to further analytical testing with antimony. The response of the electrode for a 40?nM concentration of Sb(III) was reproducible with a mean peak current of 1.07?µA and variation of 8.4% (n?=?8). The effect of metals copper, bismuth and arsenic were investigated at the electrode, as they are common interferences for stripping analysis of antimony.  相似文献   

3.
In this work, the electrochemical behavior of ferrocene (Fc) was investigated by cyclic voltammetry (CV) in room temperature ionic liquids (RTILs) of 1‐ethyl‐3‐methylimidazolium tetrafluoroborate (EMIBF4) on glass carbon (GC), edge plane pyrolytic graphite (EPPG) and multi‐walled carbon nanotube (MWCNTs)‐modified EPPG electrodes, respectively. The results demonstrated that on GC electrode, pairs of well‐defined reversible peaks were observed, while for the electrode of EPPG, the peak potential separation (ΔEp) is obviously larger than the theoretical value of 59 mV, hinting that the electrode of EPPG is distinguished from the commonly used electrode, consistent with the previous proposition that EPPG has many “defects”. To obtain an improved electrochemical response, multi‐walled carbon nanotubes (MWCNTs) were modified on the electrode of EPPG; the increased peak current and promoted peak potential separation not only proved the existence of “defects” in MWCNTs, but also supported that “creating active points” on an electrode is the main contribution of MWCNTs. Initiating the electrochemical research of Fc on the MWCNTs‐modified EPPG electrode in RTILs and verifying the presence of “defects” on both EPPG and MWCNTs using cyclic voltammograms (CVs) of Fc obtained in RTILs of EMIBF4, is the main contribution of this preliminary work.  相似文献   

4.
We investigate the electrochemical properties of CVD grown graphene towards the detection of various biologically prevalent analytes including l-ascorbic acid (AA), dopamine hydrochloride (DA), β-nicotinamide adenine dinucleotide (NADH), uric acid (UA) and epinephrine (EP). We find that the observed electrochemical response of the CVD-graphene towards these select analytes does not originate from the graphene, however, from various other contributions including the presence of 'graphitic islands' on the surface of the CVD-graphene which dominate its electrochemistry. In the systems studied within, it appears at best, CVD-graphene acts akin to that of an edge plane pyrolytic graphite (EPPG) electrode constructed from highly ordered pyrolytic graphite. However, in other cases, the response of the CVD-graphene is worse than that of an EPPG electrode, which is likely due to the low O/C ratio.  相似文献   

5.
Antimony(V) determination at an unmodified edge plane pyrolytic graphite (EPPG) electrode using anodic stripping voltammetry (ASV) by depositing beyond the hydrogen wave is shown in this paper. By depositing beyond the hydrogen wave, we report a sensitive method to determine pentavalent antimony at a carbon electrode in 0.25 M HCl. Using differential pulse anodic stripping voltammetry (DPASV), a bare EPPG electrode gave a detection limit of 5.8±0.02 nM without the need for surface modification. This level is greatly within the EU limit for drinking water of 40 nM.  相似文献   

6.
Pyrolytic carbon films (PCFs) were prepared by chemical vapor deposition (CVD) at different deposition temperatures. As an example of using PCF electrode in electroanalysis, the direct electrooxidation of ascorbic acid (AA) at the PCF electrode was investigated and compared with common carbon‐based electrodes such as glassy carbon (GC), edge plane pyrolytic graphite (EPPG), and basal plane pyrolytic graphite (BPPG) electrodes. It was found that the PCF electrodes prepared under deposition temperatures higher than 1050 °C showed a higher sensitivity and lower overpotential compared to the other carbon electrodes. The electrode was successfully applied for determination of AA in real samples.  相似文献   

7.
The performance of microchip electrophoresis/electrochemistry system with carbon nanotube (CNT) film electrodes was studied. Electrocatalytic activities of different carbon materials (single-wall CNT (SWCNT), multiwall CNT (MWCNT), carbon powder) cast on different electrode substrates (glassy carbon (GC), gold, and platinum) were compared in a microfluidic setup and their performance as microchip electrochemical detectors was assessed. An MWCNT film on a GC electrode shows electrocatalytic effect toward oxidation of dopamine (E(1/2) shift of 0.09 V) and catechol (E(1/2) shift of 0.19 V) when compared to a bare GC electrode, while other CNT/carbon powder films on the GC electrode display negligible effects. Modification of a gold electrode by graphite powder results in a strong electrocatalytic effect toward oxidation of dopamine and catechol (E(1/2) shift of 0.14 and 0.11 V, respectively). A significant shift of the half-wave potentials to lower values also provide the MWCNT film (E(1/2) shift of 0.08 and 0.08 V for dopamine and catechol, respectively) and the SWCNT film (E(1/2) shift of 0.10 V for catechol) when compared to a bare gold electrode. A microfluidic device with a CNT film-modified detection electrode displays greatly improved separation resolution (R(s)) by a factor of two compared to a bare electrode, reflecting the electrocatalytic activity of CNT.  相似文献   

8.
Saleh FS  Mao L  Ohsaka T 《The Analyst》2012,137(9):2233-2238
A new type of dehydrogenase-based amperometric glucose biosensor was constructed using glucose dehydrogenase (GDH) which was immobilized on the edge-plane pyrolytic graphite (EPPG) electrode modified with poly(phenosafranin)-functionalized single-walled carbon nanotubes (PPS-SWCNTs). The PPS-SWCNT-modified EPPG electrode was prepared by electropolymerization of phenosafranin on the EPPG electrode which had been previously coated with SWCNTs. The performance of the GDH/PPS-SWCNT/EPPG bioanode was evaluated using cyclic voltammetry and amperometry in the presence of glucose. The GDH/PPS-SWCNT/EPPG electrode possesses promising characteristics as a glucose sensor: a wide linear dynamic range of 50 to 700 μM, low detection limit of 0.3 μM, fast response time (1-2 s), high sensitivity (96.5 μA cm(-2) mM(-1)), and anti-interference and anti-fouling abilities. Moreover, the performance of the GDH/PPS-SWCNT/EPPG bioanode was tested in a glucose/O(2) biofuel cell. The maximum power density delivered by the assembled glucose/O(2) biofuel cell could reach 64.0 μW cm(-2) at a cell voltage of 0.3 V with 40 mM glucose.  相似文献   

9.
The electrochemical response of sodium levo‐thyroxin (T4) at the surface of an edge plane pyrolytic graphite (EPPG) electrode is investigated using cyclic voltammetric technique in the presence of 0.1 M HCl as supporting electrolyte. T4 underwent totally irreversible oxidation at this system and a well‐defined peak at 821 mV was obtained. Compared to the signals obtained in the optimized conditions at bare glassy carbon and carbon paste electrodes, the oxidation current of T4 at an EPPG electrode was greatly enhanced. The electrochemical process of T4 was explored and the experimental conditions were optimized. The oxidation peak current represented a linear dependence on T4 concentration from 0.01 to 10 µM. The detection limit of 3 nM (S/N=3) was obtained for 250 s accumulation at 0.3 V. Determination of T4 in a synthetic serum sample demonstrated that this sensor has good selectivity and high sensitivity.  相似文献   

10.
何正文  江奇  杨荣  亓鹏  赵斐  袁华  赵勇 《物理化学学报》2010,26(5):1214-1218
利用直流电电化学沉积法将生长碳纳米管(CNT)的催化剂镍均匀地附着在石墨电极(GE)表面,再通过化学气相沉积法制备得到原位生长碳纳米管化学修饰电极(GSCNT-CME).电化学沉积的金属镍和所制备的修饰电极分别用光学显微镜、扫描电子显微镜(SEM)和电子能谱(EDX)进行表征,所得修饰电极的电化学性能用[Fe(CN)6]3-/[Fe(CN)6]4-溶液进行表征.结果表明:经直流电电化学沉积,可以在石墨电极表面沉积一层致密的金属镍,能生长出管径均匀的碳纳米管,所制得的修饰电极具有良好的电化学响应灵敏性和准确性,可在电化学检测领域发挥重要的应用.  相似文献   

11.
应用电化学法聚合酚藏花红(PPS)功能化的单壁碳纳米管,以其作为烟酰胺辅酶(NADH)氧化的电化学催化剂(电极),构建基于乙醇脱氢酶的安培型乙醇生物电化学传感器.该电极于0.0 V时,对NADH具有很好的催化性能.而单体酚藏花红则由于其电位过低(-0.48 V),不能显示催化性能.循环伏安和计时安培法测试表明:该传感器...  相似文献   

12.
The derivatisation of carbon powder by physical adsorption of N,N'-diphenyl-p-phenylenediamine (DPPD) onto the surface of graphite particles (1-2 microm diameter) results in usefully functionalised carbon. The derivatised carbon powders have been studied using cyclic voltammetry by (i) abrasive immobilisation of the powder onto a basal plane pyrolytic graphite electrode (bppg) and (ii) by the manufacture of carbon-epoxy electrodes containing the derivatised carbon. The electrochemical response of the DPPD modified carbon has been examined in the presence of sulfide and possible reactions identified for the behaviour of each electrode substrate. The analytical application of the carbon-epoxy electrode for the sensing of sulfide is reported.  相似文献   

13.
A square wave voltammetric procedure for the determination of trace amounts of Fe(III) was developed at an unmodified edge plane pyrolytic graphite (EPPG) electrode and a screen printed electrode (SPE). This simple procedure was applied to real samples of commercially bottled mineral water. Sensitive results in the micromolar region could be achieved without modification of the electrode. Using the WHO guideline limits for the Fe(III) concentration in drinking water, recovery percentages at an EPPG gave 103 % and 107 %, and 98.6 % and 95.0 % at a SPE for the 5.36 µM (0.3 mg L?1) and 53.6 µM (3.0 mg L?1) additions of Fe(III), respectively.  相似文献   

14.
采用修饰单壁碳纳米管(SWNT、SWNT-COOH或SWNT-OH)及多壁碳纳米管(MWNT、MWNT-COOH或MWNT-OH)的石墨电极研究配位阴离子[Fe(CN)6]3-和配位阳离子[Co(phen)3]3+的电化学行为与吸附性能,借助[Co(phen)3]3+在碳纳米管(CNT)的强吸附特性制备[Co(phen)3]3+/CNT/C修饰电极,以其应用于6-MP的分析检测.结果表明:1)在CNT修饰电极上[Fe(CN)6]3-/4-呈现很好的氧化还原可逆性,而[Co(phen)3]3+则显示明显的吸附控制特征.2)[Co(phen)3]3+在多壁碳纳米管修饰电极上的吸附量较单壁碳纳米管大,但经羧基化或羟基化后,吸附量减小,而且在羧基化表面的吸附量较羟基化的大.3)[Co(phen)3]3+与6-MP间存在明显的相互作用,其配位产物的还原峰电流与6-MP浓度呈线性关系.  相似文献   

15.
The electrocatalytic oxidation of oxalate at several carbon based electrodes including basal plane (BPPG) and edge plane (EPPG) pyrolytic graphite and glassy carbon (GC) electrode, was studied. The electrodes were examined for the sensing of oxalate ions in aqueous solutions and all three electrodes showed a response to oxalate additions. The peak of oxalate oxidation at BPPG electrode appeared at lower potential, +1.13 V vs. SCE, than at EPPG (+1.20 V vs. SCE) and GC electrode (+1.44 V vs. SCE). Oxalate oxidation at BPPG electrode was studied in more details for response characteristics (potential and current), effects of pH, temporal characteristics of response potential and current. The results indicated that oxalate oxidation proceeds as two‐electron process at the BPPG electrode with a transfer coefficient β and a diffusion coefficient D evaluated to be 0.45 and 1.03 (±0.04)×10?5 cm2 s?1 respectively. The BPPG electrode was found to be suitable for oxalate determination in aqueous media showing linear response to oxalate concentration with a sensitivity of 0.039 AM?1 and a limit of detection of 0.7 μM.  相似文献   

16.
Guo K  Qian K  Zhang S  Kong J  Yu C  Liu B 《Talanta》2011,85(2):1174-1179
Characterization and application of graphene sheets modified glassy carbon electrodes (graphene/GC) have been presented for the electrochemical bio-sensing. A probe molecule, potassium ferricyanide is employed to study the electrochemical response at the graphene/GC electrode, which shows better electron transfer than graphite modified (graphite/GC) and bare glassy carbon (GC) electrodes. Based on the highly enhanced electrochemical activity of NADH, alcohol dehydrogenase (ADH) is immobilized on the graphene modified electrode and displays a more desirable analytical performance in the detection of ethanol, compared with graphite/GC or GC based bio-electrodes. It also exhibits good performance of ethanol detection in the real samples. From the results of electrochemical investigation, graphene sheets with a favorable electrochemical activity could be an advanced carbon electrode materials for the design of electrochemical sensors and biosensors.  相似文献   

17.
《Analytical letters》2012,45(8):783-803
Recent trends and challenges in developing carbon nanotubes (CNT) based sensors and biosensors for the detection of organophosphate (OP) pesticides and other organic pollutants in water are reviewed. CNT have superior electrical, mechanical, chemical, and structural properties over conventional materials such as graphite. At the same time CNT based sensors and biosensors are more efficient compared to the existing traditional techniques such as high-performance liquid chromatography or gas chromatography, because they can provide rapid, sensitive, simple, and low-cost on-field detection. The measurement protocols can be based on enzymatic and non-enzymatic detection. The enzyme acetylcholinesterase (AChE) is used with CNT for fabricating ultrasensitive biosensors for OP detection involving different immobilization schemes such as adsorption, crosslinking, and layer-by-layer self-assembly. This protocol relies on measuring the degree of enzyme inhibition as means of OP quantification. The other enzyme used along with CNT for OP detection is organophosphate hydrolase (OPH) which hydrolyzes the OP into detectable species that can be measured by amperometric or potentiometric methods. Different forms of CNT electrode materials can be used for fabricating such electrodes such as pure CNT and composite CNT. Due to their large surface area and hydrophobicity, CNT have also been used for the extraction and non-enzymatic electrochemical detection of OP with very high efficiency. The application of CNT and their novel properties for the adsorption and electrochemical detection of OP compounds is discussed in detail.  相似文献   

18.
《Electroanalysis》2005,17(1):65-72
The electrochemical activity of five different commercial carbon nanotubes (CNT), prepared by the ARC discharge and chemical vapor deposition (CVD) methods, has been assessed and compared. The various multi‐walled CNT were immobilized onto a glassy carbon electrode using three different dispersing agents (Nafion, concentrated nitric acid and dimethylformamide (DMF)) and their voltammetric response to ferricyanide, NADH and hydrogen peroxide examined. SEM was used to characterize the surface morphology. The corresponding cyclic voltammetry and amperometric data showed that the electrocatalytic activity, the background current and the electroanalytical performance are strongly depended on the preparation of the CNT and on the dispersing agent used. The most favorable amperometric detection of NADH and hydrogen peroxide is observed at the NanoLab CVD‐produced CNT in connection to a DMF‐surface dispersion. ARC‐produced CNT display a smaller capacitance, particularly in connection to the DMF dispersion. Such differences in the electrochemical reactivity are attributed to the different surface chemistries (primarily defect densities) of the corresponding CNT layers, associated with the different production and dispersion protocols.  相似文献   

19.
The voltammetric performance of glassy carbon (GC) and edge‐plane pyrolytic graphite (EPPG) electrodes was investigated for the oxidation of potassium ferrocyanide in aqueous solution both with and without the addition of surfactant (sodium dodecyl sulfate and Triton X‐100). The heterogeneous electron transfer kinetics were determined for all cases, and it was found that the GC electrode surface was far more sensitive to the presence of surfactant than the more hydrophilic EPPG surface. This result was then applied to the electroanalysis of copper via adsorptive stripping voltammetry in the presence of Triton X‐100 and it was observed that the EPPG electrode response was unaffected by up to 100 μM of surfactant, whilst the voltammetry on the GC electrode was significantly affected by only 10 μM.  相似文献   

20.
The highly sensitive determination of ofloxacin (OFL) in human serum and urine was achieved on a novel tryptophan‐graphene oxide‐carbon nanotube (Trp‐GO‐CNT) composite modified glassy carbon electrode (Trp‐GO‐CNT/GCE). The Trp‐GO‐CNT composite was fabricated, and its morphologies and surface functional groups were characterized by field emission scanning electron microscopy (FE‐SEM) and Fourier transform infrared (FT‐IR) spectroscopy. The electrochemical properties of Trp‐GO‐CNT/GCE were investigated by cyclic voltammetry (CV) and electrochemical impedance spectroscopy (EIS). The superior electrochemical behaviors of Trp‐GO‐CNT/GCE toward OFL can be mainly assigned to the excellent electrocatalytic activity of Trp, the great conductivity and high surface area of GO and CNT, and the synergistic effect between Trp, GO and CNT. Under optimum conditions, a wide and valuable linear range (0.01–100 μM), a low detection limit (0.001 μM, S/N=3), a good linear relationship (R2>0.999), good stability and repeatability were obtained for the quantitative determination of OFL. Furthermore, the Trp‐GO‐CNT electrochemical sensor was successfully applied to the determination of OFL in human serum and urine samples, and satisfactory accuracy and recovery could be obtained.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏