首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 46 毫秒
1.
In the present study a headspace solid-phase dynamic extraction method coupled to gas chromatography–mass spectrometry (HS-SPDE-GC/MS) for the trace determination of volatile halogenated hydrocarbons and benzene from groundwater samples was developed and evaluated. As target compounds, benzene as well as 11 chlorinated and brominated hydrocarbons (vinyl chloride, dichloromethane, cis-1,2-dichloroethylene, trans-1,2-dichloroethylene, carbon tetrachloride, chloroform, trichloroethylene, tetrachloroethylene, bromoform) of environmental and toxicological concern were included in this study. The analytes were extracted using a SPDE needle device, coated with a poly(dimethylsiloxane) with 10% embedded activated carbon phase (50-μm film thickness and 56-mm film length) and were analyzed by GC/MS in full-scan mode. Parameters that affect the extraction yield such as extraction and desorption temperature, salting-out, extraction and desorption flow rate, extraction volume and desorption volume, the number of extraction cycles, and the pre-desorption time have been evaluated and optimized. The linearity of the HS-SPDE-GC/MS method was established over several orders of magnitude. Method detection limits (MDLs) for the compounds investigated ranged between 12 ng/L for cis-dichloroethylene and trans-dichloroethylene and 870 ng/L for vinyl chloride. The method was thoroughly validated, and the precision at two concentration levels (0.1 mg/L and a concentration 5 times above the MDL) was between 3.1 and 16% for the analytes investigated. SPDE provides high sensitivity, short sample preparation and extraction times and a high sample throughput because of full automation. Finally, the applicability to real environmental samples is shown exemplarily for various groundwater samples from a former waste-oil recycling facility. Groundwater from the site showed a complex contamination with chlorinated volatile organic compounds and aromatic hydrocarbons. Figure SPDE Principle  相似文献   

2.
Figure Schematic diagram of a typical arrangement used for hyphenating chemical microseparations (e.g. capillary HPLC, CE, or CEC) with microcoil NMR detection  相似文献   

3.
A plunger-based extraction device for HPTLC/MS coupling, which was originally designed for extraction on TLC aluminum foils, was enhanced. The threefold modifications enabled extraction of analytes from glass-backed HPTLC/TLC plates after separation. A buffering of the plunger reduced the occurrence of leakage. The involvement of a torque screwdriver for the fixation resulted in a reproducible contact pressure and avoided breaking the glass plates. The employment of this device was also extended to plates with a layer thickness of 100 μm by reducing the height of the plunger’s cutting edge. Repeatability of the extraction from glass-backed plates, linearity of the signal obtained, and detection capability were shown to be comparable to the original device, which was only usable with aluminum foils. The influence of the elution solvent on the intensity of the MS signal was demonstrated to be a compromise between high elution power of the solvent and good solubility of the analyte in the elution solvent. The extraction device was employed for plates from different lots and for plates with different stationary phases thereby proving its general applicability in planar chromatography.   相似文献   

4.
A high-current pulsed hollow cathode discharge was used to study the role of atomic and ionic metastables involved in ionization plasma processes. We observed the enhancement of the spectral emission lines of noble gas ions in the afterglow. A study of the processes that involve atomic and ionic metastables is of great interest since it should lead to a better understanding of and enhanced control over the ionization mechanisms crucial to analytical glow discharge mass spectrometry (GDMS) analysis. Figure Time profile of Ti, Ti+, and Ne+ spectral lines  相似文献   

5.
Fiber-packed SPE tips based on electrospun fibers   总被引:1,自引:0,他引:1  
A novel fiber-packed solid-phase extraction (SPE) tip was designed based on electrospun nanofibers. The tip was used to investigate the extraction of hydrocortisone (HC), cortisone acetate (CA), ethinylestradiol (EE), and estradiol (E2). The effects of diameters, porous figurations, and functional groups of the electrospun fibers on the selectivity and efficiency were studied. The experimental results indicated that the detection limit of cortisol in water sample could be as low as 0.75 ng/mL. When the tip is used for detection of cortisol in human hair the efficiency of biological sample pretreatment is better than the traditional SPE method. Our method could significantly simplify the traditional SPE process and lower the cost. Industrial application of the tip is anticipated. Figure Analyte molecules (e.g., cortisol) are attracted onto the electrospun nanofibers of the packed SPE tip. Careful selection of the fiber diameter, morphology, and functional groups affords high selectivity, sensitivity, and extraction recoveries Electronic supplementary material  The online version of this article (doi:) contains supplementary material, which is available to authorized users.  相似文献   

6.
A new synthetic polymeric chiral stationary phase for liquid chromatography was prepared via free-radical-initiated polymerization of trans-9,10-dihydro-9,10-ethanoanthracene-(11S,12S)-11,12-dicarboxylic acid bis-4-vinylphenylamide. The new polymeric chiral stationary phase (CSP) showed enantioselectivity for many chiral compounds in multiple mobile phases. High stability and sample capacities were observed on this polymeric chiral stationary phase. Mobile phase components and additives affected chiral separation greatly. This new synthetic chiral stationary phase is complementary to two other related commercially available CSPs: the P-CAP and P-CAP-DP columns. Interactions between the chiral stationary phase and analytes that lead to retention and chiral recognition include hydrogen bonding, dipolar, and π–π interactions. Repulsive (steric) interactions also contribute to chiral recognition. Figure LC chromatograms showing the analytical (blue) and preparative (red) separations of N-(3,5-dinitrobenzoylleucine) enantiomers on a new synthetic polymeric chiral stationary phase  相似文献   

7.
Stir bar sorptive extraction in combination with thermal desorption coupled online to capillary gas chromatography–mass spectrometry was applied to investigate volatile and semivolatile fractions in two waste leachate samples: old and fresh ones. The present study helps to improve our knowledge of waste leachate organic composition. The aim is to then make use of this knowledge afterwards in order to generate more reliable and specific treatment processes for waste leachates and thus to respect the environmental statute law regarding their rejection. The volatile and semivolatile compounds appeared to be mainly anthropogenic in origin. Moreover, lactic acid and cyclic octaatomic sulfur could potentially be used as microbiological activity indicators, since they occur during organic matter degradation processes within waste leachates. Figure TDU-CGC-MS analytical equipment  相似文献   

8.
An increasing number of studies use blood obtained noninvasively to monitor organohalogen contaminants; however, blood can be difficult to analyze because of its aqueous nature and high protein content. We compared five methods for extracting polychlorinated biphenyls (PCBs), polybrominated diphenyl ethers (PBDEs), organochlorine pesticides, and lipids from serum using National Institute of Standards and Technology Standard Reference Material 1589a PCBs, Pesticides, PBDEs, and Dioxins/Furans in Human Serum. Liquid:liquid (LLE), cavity-dispersed microwave-assisted (MAE), focused microwave-assisted (FME), solid-phase (SPE), and pressurized fluid (PFE) extraction techniques were compared. FME extraction yielded the optimal recovery of internal standards (IS). All methods resulted in similar contaminant concentrations that also agreed with the certified values for SRM 1589a, except for only a few compounds measured by methods other than FME. Based on these findings, the FME method was determined to be the best overall extraction method. One procedural factor was found to affect contaminant concentrations; use of IS carrier solvents that were immiscible with serum (or when the serum was not directly physically mixed with IS) resulted in a 30% underestimation of organohalogen concentrations. This study offers valid, novel extraction alternatives beyond traditional methods (e.g., LLE) for blood contaminant measurements. Figure    相似文献   

9.
The objective of our study was to compare three vastly different analytical methods for measuring urinary metabolites of pyrethroid and pyrethrum insecticides to determine whether they could produce comparable data and to determine if similar analytical characteristics of the methods could be obtained by a secondary laboratory. This study was conducted as a part of a series of validation studies undertaken by the German Research Foundation’s Committee on the Standardization of Analytical Methods for Occupational and Environmental Medicine. We compared methods using different sample preparation methods (liquid–liquid extraction and solid-phase extraction with and without chemical derivatization) and different analytical detection methods (gas chromatography–mass spectrometry (single quadrupole), gas chromatography–high resolution mass spectrometry (magnetic sector) in both electron impact ionization and negative chemical ionization modes, and high-performance liquid chromatography–tandem mass spectrometry (triple quadrupole) with electrospray ionization). Our cross validation proved that similar analytical characteristics could be obtained with any combination of sample preparation/analytical detection method and that all methods produced comparable analytical results on unknown urine samples. Cross-method comparison using unknown urine samples revealed reasonably good agreement for any combination of the methods tested  相似文献   

10.
We screened a series of RNA and DNA aptamers for their ability to serve in the dye displacement assays in which analytes compete with TO dye. We conclude that, while the performance of the TO dye displacement approach is not always predictable, it is still a simple and sensitive assay to detect binding between RNA aptamers and small molecules. In particular, we describe efficient assays for tobramycin and theophylline, with up to 90% displacement of TO observed, and we describe the first aptameric assay for cAMP. Figure An RNA or DNA aptamer against a molecule (circle) binds TO dye, resulting in a fluorescent complex. Presence of free molecule in solution results in the displacement of TO from the complex and a reduction in fluorescence Electronic supplementary material The online version of this article (doi:) contains supplementary material, which is available to authorized users.  相似文献   

11.
A novel method of determining organochlorine pesticides (OCPs) is described. It is based on solid-phase microextraction (SPME) and gas chromatography–electron capture detection. During the development of the method, soil samples were prepared, spiked with standard solution, and then aged for some time. Extraction conditions such as the extraction time, the NaCl content, the volume of water, the extraction temperature and the desorption time were investigated and optimized. The limits of detection obtained using the method ranged from 0.10 to 0.51 ng g−1, and relative standard deviations were lower than 10% for most organochlorine pesticides. Real soil samples were successfully analyzed using the proposed method. The results from the method developed here were in good agreement with those obtained using ultrasonic extraction. The result demonstrates that aging soils spiked with standard solution is an important method development step, because the soil samples obtained using this approach are more like real soils than those obtained when aging is not used.   相似文献   

12.
We are reporting a method for measuring 43 polycyclic aromatic hydrocarbons (PAH) and their methylated derivatives (Me-PAHs) in air particulate matter (PM) samples using isotope dilution gas chromatography/high-resolution mass spectrometry (GC/HRMS). In this method, PM samples were spiked with internal standards, loaded into solid phase extraction cartridges, and eluted by dichloromethane. The extracts were concentrated, spiked with a recovery standard, and analyzed by GC/HRMS at 10,000 resolution. Sixteen 13C-labeled PAHs and two deuterated Me-PAHs were used as internal standards to account for instrument variability and losses during sample preparation. Recovery of labeled internal standards was in the range of 86–115%. The proposed method is less time-consuming than commonly used extraction methods, such as sonication and accelerated solvent extraction (ASE), and it eliminates the need for a filtration step required after the sonication extraction method. Limits of detection ranged from 41 to 332 pg/sample for the 43 analytes. This method was used to analyze reference materials from the National Institute of Standards and Technology. The results were consistent with those from ASE and sonication extraction, and these results were also in good agreement with the certified or reference concentrations. The proposed method was then used to measure PAHs on PM2.5 samples collected at three sites (urban, suburban, and rural) in Atlanta, GA. The results showed distinct seasonal and spatial variation and were consistent with an earlier study measuring PM2.5 samples using an ASE method, further demonstrating the compatibility of this method and the commonly used ASE method.   相似文献   

13.
A new approach for headspace sorptive extraction is presented and demonstrated for the determination of 12 chlorobenzenes in water samples. It consists of a silicone tube (15-mm length) arranged around a stainless steel rod. This device is fixed on a septum cap and exposed to the headspace of 50 mL of a salt-saturated water sample. After extraction (60-min optimized extraction time), thermodesorption is carried out by direct insertion of the silicone tube into the thermodesorption-gas chromatography-mass spectrometry system. Desorption of the analytes is performed at 250 °C for 5 min with a gas flow of 50 mL/min. Repeatability (relative standard deviation 5–10%), extraction yields (9–46%), enrichment factors (129–657), and detection limits (0.002–0.012 μg/L) were determined and four real water samples were analyzed with the headspace tube extraction. The results were verified by standard addition. A comparison of headspace tube extraction with other headspace enrichment techniques underlined the high extraction capacity of the proposed method. A big advantage of tube extraction is the low cost of the silicone material. The tubes can be discarded after single use, avoiding carryover problems and cross-contamination. Figure Scheme of the HS-tube extraction and thermodesorption system  相似文献   

14.
The forms and quantities of iron species in corrosion product samples from natural gas pipelines were examined, using a continuous-flow sequential extraction system. Sequential extraction consists of four steps that dissolve water soluble iron (FeSO4), acid soluble iron (FeCO3), reducible iron (Fe-(oxyhydr)oxides) and oxidisable iron (FeS2) fractions, respectively. Selectivity of extracting reagents for particular iron species was evaluated by determination of co-extracted anions, using ion chromatography, and evolved CO2, using indirect flame atomic absorption spectrometer (FAAS). Iron was found predominantly in the reducible fraction (61–99%), indicating that Fe-(oxyhydr)oxides are the major constituents of the corrosion products.   相似文献   

15.
Electrokinetic sample extraction and enrichment is introduced as a newly developed concept for the analysis of substances in sludge-type or paste-like matrices. It is based on electrokinetic transport phenomena as electromigration and electroosmosis occurring when an electrical field is applied to the fresh, wet samples. Problems usually associated to sample drying can be avoided, e.g., losses of volatile analytes or contamination. We have designed and built a suitable apparatus for electrokinetic sample extraction and enrichment. Appropriate operating conditions (field strength, buffer composition, concentration, and volume) were identified in experiments with an artificial sludge model and real-world lake sediments. A proof of principle of the method was provided by the electromigrative extraction and online enrichment on a solid-phase sorbent disk of an azo dye from a diatomaceous earth slurry. Electroosmotic extraction and enrichment of a cyanobacterial hepatotoxin at trace levels was finally investigated as an application example using lake sediments. Rather clean extracts were obtained even with high organic content sediment samples, as shown by high-performance liquid chromatography with diode array detection.   相似文献   

16.
A method based on solid-phase microextraction (SPME) and gas chromatography-mass spectrometry (GC-MS) has been optimized for the determination of fragrance allergens in water samples. This is the first study devoted to this family of cosmetic ingredients performed by SPME. The influence of parameters such as fibre coating, extraction and desorption temperatures, salting-out effect and sampling mode on the extraction efficiency has been studied by means of a mixed-level factorial design, which allowed the study of the main effects as well as two-factor interactions. Excluding desorption temperature, the other parameters were, in general, very important for the achievement of high response. The final procedure was based on headspace sampling at 100 °C, using polydimethylsiloxane/divinylbenzene fibres. The method showed good linearity and precision for all compounds, with detection limits ranging from 0.001 to 0.3 ng mL−1. Reliability was demonstrated through the evaluation of the recoveries in different real water samples, including baby bathwater and swimming pool water. The absence of matrix effects allowed the use of external standard calibration to quantify the target compounds in the samples. The proposed procedure was applied to the determination of allergens in several real samples. All the target compounds were found in the samples, and, in some cases, at quite high concentrations. The presence and the levels of these chemicals in baby bathwater should be a matter of concern. Baby exposure to fragrance allergens and other cosmetic ingredients through the daily bath  相似文献   

17.
A solid-phase microextraction method (SPME) followed by gas chromatography with micro electron capture detection for determining trace levels of nitro musk fragrances in residual waters was optimized. Four nitro musks, musk xylene, musk moskene, musk tibetene and musk ketone, were selected for the optimization of the method. Factors affecting the extraction process were studied using a multivariate approach. Two extraction modes (direct SPME and headspace SPME) were tried at different extraction temperatures using two fiber coatings [Carboxen–polydimethylsiloxane (CAR/PDMS) and polydimethylsiloxane–divinylbenzene (PDMS/DVB)] selected among five commercial tested fibers. Sample agitation and the salting-out effect were also factors studied. The main effects and interactions between the factors were studied for all the target compounds. An extraction temperature of 100 °C and sampling the headspace over the sample, using either CAR/PDMS or PDMS/DVB as fiber coatings, were found to be the experimental conditions that led to a more effective extraction. High sensitivity, with detection limits in the low nanogram per liter range, and good linearity and repeatability were achieved for all nitro musks. Since the method proposed performed well for real samples, it was applied to different water samples, including wastewater and sewage, in which some of the target compounds (musk xylene and musk ketone) were detected and quantified. Figure Stardardized Pareto charts for the main effects and interactions  相似文献   

18.
The efficiencies of two traditional extraction methods used in Chinese medicine (the decoction method and the maceration method) were evaluated for the extraction of antioxidants from medicinal plants. A group of medicinal plants possessing nutritious and tonic functions were chosen as model plants. A commonly used extraction method was used as a reference method. The antioxidant capacities and total phenolic contents of the extracts were measured by ferric-reducing antioxidant power and Trolox equivalent antioxidant capacity assays as well as the Folin–Ciocalteu method, respectively. The results obtained indicated that the two traditional extraction methods could effectively extract antioxidants from medicinal plants. These extraction methods can be applied to the analysis and purification of antioxidants in plants, respectively. At home, people can use these methods to extract antioxidants from plants for consumption. In the food industry, these methods could be utilized to prepare crude extracts from plants containing antioxidants for use as food additives. Figure Relation and comparison of extraction efficiencies of two traditional extraction methods with the reference method Electronic supplementary material The online version of this article (doi:) contains supplementary material, which is available to authorized users.  相似文献   

19.
Bead injection in a lab-on-valve (LOV) system was adopted for DNA purification via micro solid-phase extraction (SPE) with a renewable silica microcolumn packed in a channel of the LOV unit. The complex matrix components in human whole blood, including proteins, were well eliminated by choosing properly the sample loading and elution media. The DNA purification process was monitored on-line by using laser-induced fluorescence in a demountable side part of the LOV unit incorporating optical fibers. The practical applicability of the entire system was demonstrated by separation/purification of λ-DNA in a simulated matrix and human blood genetic DNA by performing SPE, in situ monitoring of the purified products, and postcolumn PCR amplification. When DNAs in a simulated matrix (10.0 ng μl−1 λ-DNA, 50 ng μl−1 bovine serum albumin, 1.0% Triton X-100) were processed in the present system and laser-induced fluorescence was monitored at 610 nm, an overall extraction/collection efficiency of 70% was achieved by employing identical sample loading and an elution flow rate of 0.5 μl s−1, along with a precision of 3.8% relative standard deviation. DNA separation and purification from human whole-blood samples were performed under similar conditions. Figure Lab-on-valve mesofluidic system employed for DNA separation and purification integrating a demountable fluorescence flow cell for in-situ laser induced fluorescence detection  相似文献   

20.
We used Fourier transform infrared spectromicroscopy in the attenuated total reflection configuration to study biochemical events associated with the response to light of an intact retina. We show that the technique is suitable for the detection in real time of molecular processes occurring in rod outer segments induced by light absorption. Two-dimensional correlation analysis was applied to the identification and interpretation of specific spectral changes associated to the evolution of the system. The technique allows us to observe an extensive protein translocation, which we interpret as arising from the release of transducin from the disk membrane and its redistribution from the outer segment towards the inner segment of rod cells. These results are in full agreement with our current understanding of retinal physiology and validate the technique as a useful tool for the study of complex molecular processes in intact tissue. Figure Spectral changes in the mid infrared region following exposure of an intact retina to light  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号