首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
利用自制的以聚(乙烯基咪唑-二乙烯基苯)(VIDB)整体材料为涂层的固相萃取搅拌棒(VIDB-SBSE)萃取3种硝基呋喃类药物,然后与高效液相色谱-二极管阵列检测器联用建立了测定饲料和水样品中硝基呋喃类药物残留的方法。详细考察了萃取过程中萃取和解吸时间、样品基质的pH值以及离子强度等实验条件对萃取效率的影响。在最佳条件下,呋喃唑酮的线性范围为0.5~200μg/L,呋喃妥因和呋喃西林的线性范围为0.25~200μg/L,3种目标物的检出限(LO D)(S/N=3)在0.068~0.11μg/L之间,所建方法具有理想的日内和日间重现性(R SD值均小于6%)。在对饲料和实际水样的测定中,不同加标浓度呋喃唑酮、呋喃妥因和呋喃西林的回收率在80.6%~108%之间。研究表明,所建立的方法具有简便、灵敏、环境友好等特点。  相似文献   

2.
An optimized method using stir bar sorptive extraction (SBSE) for the determination of 25 polychlorinated biphenyls (PCBs) from water samples among them three of the most toxic coplanar PCBs (PCB 77, PCB 126 and PCB 169) was developed. Since the investigated PCBs comprise all steps of chlorination (from PCB 1 as monochlorobiphenyl to PCB 209 as decachlorobiphenyl) the results should be representative for the total class of the 209 PCB congeners. For 8 ml spiked water samples with 2 ml methanol addition and 2 h exposure time of stir bars recoveries between 28% (PCB 209) and 93% (PCB 1, PCB 52, PCB 77) were found. Detection limits between 0.05 ng/l and 0.15 ng/l were calculated for the combination of SBSE and thermodesorption-GC/MS. The procedure was applied to the investigation of groundwater and river water samples from the industrial region of Bitterfeld northern Leipzig, Germany.  相似文献   

3.
Benzotriazole UV stabilizers are emerging compounds used in personal care products and can enter surface water after passing through wastewater treatment plants without being removed. Because these analytes are strongly hydrophobic, there is an environmental risk of accumulation in solid matrices and magnification through the trophic chain. In this work, a method based on stir bar sorption extraction with liquid desorption is presented for the extraction of benzotriazole UV stabilizers from water samples. Stir bar sorptive extraction was combined with ultra‐high performance LC with MS/MS detection. All important factors affecting the stir bar sorptive extraction procedure are discussed, and the optimized method was applied to seawater and wastewater samples from Gran Canaria Island, providing good selectivity and sensitivity with LODs and limits of quantification in the range of 18.4–55.1 and 61.5–184 ng/L, respectively. Recoveries between 68.4–92.2% were achieved for the more polar compounds, whereas the recoveries were lower for the two less polar compounds, most likely due to their strong absorption into the polydimethylsiloxane stir bar phase that does not allows the complete desorption. The repeatability studies gave RSDs of between 6.45 and 12.6% for all compounds in the real samples.  相似文献   

4.
Two new commercially available polar coatings for stir bar sorptive extraction (SBSE), consisting of polyacrylate (PA) with a proportion of polyethyleneglycol (PEG) (Acrylate Twister®) and PEG modified silicone (EG Silicone Twister®), were evaluated and compared with the classic coating based on polydimethylsiloxane (PDMS Twister®) for the extraction of a group of pharmaceuticals and personal care products (PPCPs) from wastewater samples.  相似文献   

5.
The objective of this study was the optimization and comparison of two extraction methods for the determination of polycyclic aromatic hydrocarbons (PAHs) in wastewater (WW). A distribution study of the target compounds between the aqueous phase and the suspended particulate matter (SPM) has been performed in order to establish whether the analysis of both phases is necessary. In this sense, the feasibility of stir bar sorptive extraction (SBSE) and solid-phase extraction (SPE) for the determination of 24 PAHs in WW samples has been evaluated. The results demonstrated the suitability of SBSE to perform a comprehensive analysis of liquid samples containing high amounts of SPM, such as in the determination of PAHs in WWs. A gas chromatography triple quadrupole mass spectrometry (GC-QqQ-MS/MS) method has been also optimized for the separation and detection of the target compounds, avoiding the co-elution of some groups of isomers, such as benzo[b], [j] and [k] fluoranthenes and indene[1,2,3-cd]pyrene/dibenz[a,h]anthracene. For that purpose, a specific capillary column developed for PAH determination was used. The SBSE procedure was validated and adequate parameters (such as recovery, linearity, precision, limits of detection and quantification) were obtained. Finally, the validated method was applied to the analysis of real samples collected from an experimental WW treatment plant, detecting some PAHs at concentrations in the range 0.007-0.022 μg L(-1).  相似文献   

6.
Stir bar sorptive extraction (SBSE) in combination with thermal desorption-gas chromatography-mass spectrometry (TD-GC-MS) was applied for the determination of 9 UV filters in water samples. The stir bar coated with polydimethylsiloxane (PDMS) was added to 20 mL of water sample at pH 2 (10% MeOH) and stirred at 1000 rpm for 180 min. Then, the stir bar was subjected to TD-GC-MS. The desorption conditions (desorption temperature and desorption time) and SBSE parameters (ionic strength, pH, presence of organic solvent and time) were optimised using a full factorial design and a Box-Behnken design, respectively. The method shows good linearity (correlation coefficients >0.994) and reproducibility (RSD<16%). The extraction efficiencies were above 63% for all the compounds. Detection limits were between 0.2 and 63 ng/L. The developed method offers the ability to detect several UV filters at ultra-low concentration levels with only 20 mL of sample volume. The effectiveness of the method was tested by analysing real samples such as lake water, river water and treated wastewater. The application of the method allowed reporting the levels of UV filters in environmental water samples.  相似文献   

7.
Nguyen KT  Scapolla C  Di Carro M  Magi E 《Talanta》2011,85(5):2375-2384
Fast liquid chromatography coupled to triple-quadrupole tandem mass spectrometry was employed for the determination of six UV filters in seawater. The separation of the analytes was achieved in less than 5 min; polarity switching was used as four of the analytes were ionized in positive mode and the remaining two in negative mode. Two ionization sources were employed and compared: atmospheric pressure chemical ionization (APCI) gave better results than electrospray ionization (ESI) for all analytes, with higher reproducibility and lower detection limits. Therefore APCI was chosen for the determination of the analytes in seawater samples using stir bar sorptive extraction-liquid desorption (SBSE-LD).Quantitative analysis was performed in multiple reaction monitoring (MRM) mode; fragmentation pathways of the analytes with regard to the formation of the MRM ions were also proposed.For the analysis of seawater samples, calibration curves were drawn using SBSE in spiked seawater. All figures of merit of the method were satisfactory; limits of detection were particularly low for the four analytes ionized in positive mode, being in the range 8-31 ng/L. The method was applied to the determination of the six UV filters in seawater samples from Liguria, Italy. Only benzophenone-3 (BP-3) and ethylhexyl methoxycinnamate (EHMC) were measured in the analyzed samples; some of the remaining analytes were also detected but always below the limit of quantitation.  相似文献   

8.
This study presents the development of an analytical method for determining 9 synthetic musks in water matrices. The developed method is based on stir bar sorptive extraction (SBSE), coated with polydimethylsiloxane, and coupled with a thermal desorption–gas chromatography–mass spectrometry system (TD–GC–MS). SBSE can efficiently trap and desorb the analytes providing low limits of detection (between 0.02 ng L−1 and 0.3 ng L−1). Method validation showed good linearity, repeatability and reproducibility for all compounds. Furthermore, the limited manipulation of the sample required in this method implies a significant decrease of the risk of external contamination of the samples. The performance of the method in real samples was evaluated by analysing biological wastewater treatment plant (WWTP) influent and effluent samples, reverse osmosis treatment plant effluents and river waters. The most abundant musk was galaxolide with values up to 2069 ng L−1 and 1432 ng L−1 in the influent and effluent of urban WWTP samples, respectively. Cashmeran, Pantolide and Tonalide were also detected in all the matrices with values up to 94 ng L−1, 26 ng L−1 and 88 ng L−1, respectively. Although in Europe the use of nitromusks in cosmetics is prohibited, musk xylene and musk ketone were detected both in the WWTP and in the river samples. As far as we know, this is the first time than a SBSE method coupled with TD is applied for the determination of synthetic musks in water samples.  相似文献   

9.
This study presents the optimization and application of an analytical method based on the use of stir bar sorptive extraction (SBSE) gas chromatography coupled to mass spectrometry (GC–MS) for the ultra-trace analysis of POPs (Persistent Organic Pollutants) in Arctic ice. In a first step, the mass-spectrometry conditions were optimized to quantify 48 compounds (polycyclic aromatic hydrocarbons, brominated diphenyl ethers, chlorinated biphenyls, and organochlorinated pesticides) at the low pg/L level. In a second step, the performance of this analytical method was evaluated to determine POPs in Arctic cores collected during an oceanographic campaign. Using a calibration range from 1 to 1800 pg/L and by adjusting acquisition parameters, limits of detection at the 0.1–99 and 102–891 pg/L for organohalogenated compounds and polycyclic aromatic hydrocarbons, respectively, were obtained by extracting 200 mL of unfiltered ice water. α-hexachlorocyclohexane, DDTs, chlorinated biphenyl congeners 28, 101 and 118 and brominated diphenyl ethers congeners 47 and 99 were detected in ice cores at levels between 0.5 to 258 pg/L. We emphasise the advantages and disadvantages of in situ SBSE in comparison with traditional extraction techniques used to analyze POPs in ice.  相似文献   

10.
Stir bar sorptive extraction (SBSE) and thermal desorption followed by capillary gas chromatography coupled to mass spectrometry (SBSE-TD-GC-MS) was applied to the simultaneous determination of ultra-traces of 16 polycyclic aromatic hydrocarbons (PAHs), 12 polychlorinated biphenyls (PCBs), 6 phthalate esters (PEs) and 3 nonylphenols (NPs) in water samples. The parameters that could affect the sorption-desorption efficiency were studied. A Plackett-Burman design was used for the screening of the main effects of the experimental parameters related to the desorption step (desorption time, desorption temperature, desorption flow, cryo-focusing temperature and vent pressure). Afterwards, two central composite designs were used to find the optimal process settings for the extraction and desorption steps. The best analytical compromise conditions for the simultaneous determination of analytes from spiked water samples were found to be: sample volume (20 mL), sodium chloride addition (30%), methanol addition (20%), desorption time (10 min), desorption temperature (300 degrees C), desorption flow (23 mL min(-1)), cryo-focusing temperature (-50 degrees C) and vent pressure (7 psi). Remarkable recovery, repeatability and reproducibility were attained. Furthermore, excellent linearities (r(2) = 0.959-0.999) and low detection limits (0.1-10 ng L(-1)) were also achieved for the congeners studied. The proposed methodology was applied for the simultaneous determination of PAHs, PCBs, PEs and NPs in sea and estuarine waters. The influence of humic acids on the recovery was also studied.  相似文献   

11.
A simple, efficient, and sensitive method for simultaneous determination of sorbic acid (SA), benzoic acid (BA), and cinnamic acid (CA) in juices and soft drinks was developed by stir cake sorptive extraction (SCSE) coupling to high-performance liquid chromatography with diode array detection. The SCSE based on polymeric ionic liquid-based monolith (PILM) as extractive medium was used to concentrate these three organic acid preservatives. Because hydrophobic and ion-exchange interactions co-contributed to the extraction, the PILM-SCSE exhibited a high extractive capability towards analytes. To obtain optimum extraction performance, several SCSE parameters were investigated and discussed, including desorption solvent, pH value, ionic strength in the sample matrix, and the extraction and desorption time. Under the optimized extraction conditions, limits of detection of 0.16, 1.08, and 0.18 μg/L (S/N?=?3) and quantification limits of 0.52, 3.42, and 0.61 (S/N?=?10) were obtained for SA, BA, and CA, respectively. The method also showed good linearity and reproducibility, as well as advantages such as simplicity, low cost, and high feasibility. Finally, the proposed method was successfully applied to the determination of SA, BA, and CA in real juices and soft drinks, and the recoveries ranged from 63.0 to 107 %.  相似文献   

12.
An analytical method was developed to detect the three sulfonamides para-toluenesulfonamide (p-TSA), ortho-toluenesulfonamide (o-TSA) and benzenesulfonamide (BSA) in environmental water samples at concentrations down to 0.02 microg/L using liquid chromatography coupled to tandem mass spectrometry (HPLC-MS/MS). Wastewater, surface water, groundwater and drinking water samples from Berlin (Germany) were analysed for all three compounds which appear to be ubiquitously present in the aquatic environment. p-TSA was found in high concentrations in the wastewater (<0.02-50.8 microg/L) and in groundwater below a former sewage farm (<0.02-41 microg/L), and in lower concentrations in the surface water (<0.02 to 1.15 microg/L) and drinking water (<0.02-0.27 microg/L). o-TSA and BSA were detected in considerably lower concentrations. The study makes clear that p-TSA should be monitored because of its comparatively high concentration in Berlin's drinking water.  相似文献   

13.
A method is described for the determination of 16 sulfonamides in honey. Samples are dissolved in phosphoric acid solution (pH2), cleaned up with 2 solid-phase extraction (SPE) cartridges, an aromatic sulfonic cation-exchange cartridge and an Oasis HLB SPE cartridge, and analyzed both qualitatively and quantitatively by liquid chromatography/tandem mass spectrometry (LC/MS/MS) under the selected conditions. Without exception, calibration curves were linear (r = > 0.995), when sulfamethizole was between 1.0 and 25.0 microg/kg; sulfacetamide, sulfapyridine, sulfadiazine, sulfachloropyridazine, sulfamethoxazole, sulfamerazine, sulfisoxazole, sulfamonomethoxine, and sulfadoxine were between 2.0 and 50.0 microg/kg; sulfamethoxypyridazine, sulfadimethoxine, and sulfathiazole were between 4.0 and 100.0 microg/kg; sulfamethazine and sulfameter were between 8.0 and 200.0 microg/kg; and sulfaphenazole was between 12.0 and 300.0 microg/kg. Average recoveries at 4 fortification levels in the range of 1.0-300 microg/kg in honey were 70.9-102.5%, and relative standard deviations were 2.02-11.52%. The limits of quantitation for the 16 sulfonamides were between 1.0 and 12.0 microg/kg, with the LC/MS/MS method.  相似文献   

14.
Ye S  Yao Z  Na G  Wang J  Ma D 《Journal of separation science》2007,30(15):2360-2369
This paper describes a rapid method for the determination of 14 kinds of sulfonamides (SAs) in wastewater using SPE, and LC-MS/MS with positive ESI (ESI(+)) and selected reaction monitoring (SRM) mode. The SPE was performed on an Oasis hydrophilic-lipophilic-balanced (HLB) cartridge. Chromatographic separation on a C18 column was achieved using a binary eluent containing methanol and water with 0.2% formic acid. Typical recoveries of the analytes ranged from 22.3 to 87.0% at a fortification level of 100 ng/L. The LODs in wastewater except sulfathiazole (3 ng/L) could be detected and quantified at levels as low as 1 ng/L. Finally, the method was applied to water from the municipal outlet and the aquaculture wastewater effluent. Sulfamethazine (SM(2)), sulfamethoxypyridazine (SMP), and sulfamethoxazole (SMZ) were most frequently found in wastewater in a concentration range between 1.2 and 31.7 ng/L.  相似文献   

15.
A method for the simultaneous determination of 46 semi-volatile organic contaminants and pollutants in saffron has been developed for the first time using a stir bar sorptive extraction technique and thermal desorption in combination with gas chromatography-ion trap tandem mass spectrometry. The analytical method proposed was easy, rapid and sensitive and showed good linearity, accuracy, repeatability and reproducibility over the concentration range tested. Moreover, the correlation coefficients were higher than 0.98 for all target compounds and detection limits were lower than 1 microg/kg except for simazine. The present method was also applied for the analysis of trace contaminants in saffron samples.  相似文献   

16.
A stir bar sorptive extraction method for the determination of volatile compounds in orange juices was developed. The extraction variables were optimized using a reduced two‐level factorial screening design (25‐1), and the most suitable analytical conditions for the extraction of the studied compounds were: sample volume 10 mL, extraction time 60 min, stirring speed 1800 rpm, NaCl amount 30% (weight/volume), and twister length 10 mm. The optimized method was further validated, obtaining good linearity and detection and quantification limits low enough to correctly determine the studied compounds. As well, for most of the studied compounds precision and recovery values were good. Several orange juice samples (squeezed and commercial) were extracted following the optimized extraction method and analyzed by gas chromatography coupled to mass spectrometry detection. The method has proven to be suitable for the determination of the aroma of orange juice, of which limonene was the major volatile compound in all the studied samples.  相似文献   

17.
A sensitive and precise stir bar sorptive extraction (SBSE) combined with LC (SBSE/LC) analysis is described for simultaneous determination of methyl, ethyl, propyl, and butyl parabens in commercial cosmetic products in agreement with the European Union Cosmetics Directive 76/768/EEC. Important factors in the optimization of SBSE efficiency are discussed, such as time and temperature of extraction, pH, and ionic strength of the sample, matrix effects, and liquid desorption conditions by different modes (magnetic stirring, ultrasonic). The LOQs of the SBSE/LC method ranged from 30 to 200 ng/mg, with linear response over a dynamic range, from the LOQ to 2.5 μg/mg, with a coefficient of determination higher than 0.993. The interday precision of the SBSE/LC method presented a coefficient of variation lower than 5%. The effectiveness of the proposed method was proven for analysis of commercial cosmetic products such as body creams, antiperspirant creams, and sunscreens.  相似文献   

18.
A combined stir bar coated with poly (dimethysiloxane)-beta-cyclodextrin (PDMS-beta-CD) on single side has been prepared for the first time by sol-gel method and was coupled with ultrasonic assisted extraction (UAE) for the determination of some brominated flame-retardant compounds (BFRs) in soil and dust samples by high performance liquid chromatography (HPLC). Four different kinds of coatings including PDMS-beta-CD, PDMS, carbowax (CW)-PDMS-poly (vinyl alcohol) (PVA) and PDMS-PVA were evaluated for stir bar sorptive extraction of BFRs by orthogonal experiment design. The experimental results reveal that the PDMS-beta-CD combined stir bar exhibited the best extraction efficiency for the target analytes. The reproducibility for the preparation of PDMS-beta-CD combined stir bar ranged from 1.3% to 15.7% in one batch, and 7.2% to 15.1% among batches. Extraction time, desorption solvent, concentration of methanol and NaCl in the matrix, pH, temperature and stirring speed were optimized. The combined stir bar can avoid direct friction of the coating with the bottom of the vessel, and could be used for more than 100 times. Linearity (>0.993), repeatability (<10.5%), reproducibility (<16.5%), recovery (56-118%) and detection limits (2.9-4.2 microg L(-1)) were proper to determine the seven BFRs. The developed method was applied to the determination of BFRs in soil and dust with satisfactory results.  相似文献   

19.
A rapid and sensitive LC‐MS/MS method for the quantification of fenofibric acid in rat plasma was developed and validated. Plasma samples were prepared by liquid–liquid extraction with a mixture of N‐hexane–dichloromethane–isopropanol (100:50:5, v/v/v). Isocratic chromatographic separation was performed on a reversed‐phase Discovery C18 column (2.1 × 50 mm, 5 µm). The mobile phase was methanol–water–formic (75:25:0.25, v/v/v). Detection of fenofibric acid and the internal standard (IS) diclofenac acid was achieved by ESI MS/MS in the negative ion mode using m/z 317 → m/z 213 and m/z 294 → m/z 250 transitions, respectively. The method was linear from 0.005 to 1.250 µg/mL when 100 μL plasma was analyzed. The lower limit of quantification was 0.005 µg/mL. The intra‐ and inter‐day precision values were below 8.2%, and accuracy ranged from ?0.9 to 2.1% in all quality control samples. The recovery was 90.3–94.7% and 83.3% for fenofibric acid and IS, respectively. Total run time for each sample analysis was 2.5 min. The validated method was successfully applied to a pharmacokinetic study in six rats after oral administration of fenofibrate, the ester prodrug of fenofibric acid (equivalent to fenofibric acid 5 mg/kg). The method permits laboratory scientists with access to the appropriate instrumentation to perform rapid fenofibric acid determination. Copyright © 2011 John Wiley & Sons, Ltd.  相似文献   

20.
A novel, rapid and sensitive isocratic liquid chromatography/tandem mass spectrometry (LC/MS/MS) method was developed for quantification of docetaxel in human plasma with paclitaxel as internal standard. The high sensitivity and specificity of MS/MS detection enabled the use of a small volume of plasma (0.05 mL) and a simple liquid-liquid extraction procedure. Furthermore, a very short run-time (3 min) fulfilled the need for monitoring plasma levels of docetaxel from large-scale clinical studies. The calibration curve for docetaxel was linear over the range 5-1000 ng/mL with coefficients of correlation >0.999 using only 0.05 mL plasma. The intra- and inter-day precisions (CV) of analysis were <7%, and accuracy ranged from 96 to 110%. The applicability of the method was demonstrated in a pharmacokinetic study of a 1-h infusion of docetaxel with dosages of 75 mg/m(2). Possible conjugated metabolites of docetaxel were not detected in patients' samples.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号