首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 369 毫秒
1.
研究了盐酸阿比朵尔在鲁米诺-K3Fe(CN)6化学发光反应体系中的后化学发光反应. 据此建立了测定盐酸阿比朵尔的流动注射后化学发光分析法. 方法的线性范围为6.0×10-9~1.0×10-7 g/mL, 检出限(3σ)为2×10-9 g/mL. 对4.0×10-8 g/mL的盐酸阿比朵尔溶液连续11次平行测定, RSD=1.3%. 方法已用于盐酸阿比朵尔胶囊及尿样中盐酸阿比朵尔含量的测定. 在对这一后化学发光反应的动力学性质、化学发光光谱、紫外可见吸收光谱以及一些相关问题研究的基础上, 提出了可能的反应机理.  相似文献   

2.
研究了双嘧达莫在铁氰化钾-鲁米诺化学发光反应体系中的后化学发光反应, 并在研究其反应的动力学性质、化学发光光谱、荧光光谱以及一些相关问题的基础上, 探讨了反应机理; 合成了双嘧达莫的分子印迹聚合物, 以此聚合物为分子识别物质, 利用铁氰化钾-鲁米诺-双嘧达莫后化学发光体系, 建立了测定双嘧达莫的高选择性分子印迹-后化学发光分析方法. 所建方法的线性范围为1.0×10-8-1.0×10-6 g/mL(r=0.999 2), 检出限为3×10-9 g/mL, 相对标准偏差为2.7%(1.0×10-7 g/mL双嘧达莫, n=11).  相似文献   

3.
A novel, rapid and sensitive analytical method is described for determination of ofloxacin and levofloxacin by enhanced chemiluminescence (CL) with flow-injection sampling. The method is based on the CL reaction of the Ce(IV)-Na2S2O4-ofloxacin/levofloxacin-H2SO2 system. The enhanced CL mechanism was developed and the optimum conditions for CL emission were investigated. The CL intensity was correlated linearly (r = 0.9988) with the concentration of ofloxacin (or levofloxacin) in the range of 1.0 x 10(-8) - 1.0 x 10(-7) g ml(-1) and 1.0 x 10(-7) - 6.0 x 10(-6) g ml(-1). The detection limit (S/N = 3) is 7 x 10(-9) g ml(-1). The relative standard derivation (RSD, n = 11) is 2.0% for ofloxacin at 4 x 10(-7) g ml(-1) and for levofloxacin at 6 x 10(-7) g ml(-1). This method has been successfully applied for the determination of ofloxacin and levofloxacin in pharmaceutical preparations and biological fluids with satisfactory results.  相似文献   

4.
A rapid and sensitive chemiluminescence (CL) method using flow injection analysis was described for the determination of three catecholamines: dopamine, adrenaline and dobutamine, based on their greatly enhancing effects on the CL reaction of luminol-potassium periodate in basic solutions. Under the optimized conditions, the calibration graphs relating the increase of CL intensity to the concentration of the analytes were linear. The present method allows for the determination of dopamine, adrenaline, and dobutamine over the range of 1.0 x 10(-10) - 1.0 x 10(-7) g/ml. The relative standard deviations for measurements (n=11) of dopamine, adrenaline and dobutamine were 2.9, 2.3 and 1.8% when the concentrations of three catecholamines were at 1.0 x 10(-9) g/ml, respectively. The detection limits of the method were 2.0 x 10(-11) g/ml dopamine, 1.0 x 10(-11) g/ml adrenaline and 4.0 x 10(-11) g/ml dobutamine. The method was successfully applied to the determination of three catecholamines in pharmaceutical samples and blood plasma.  相似文献   

5.
A new post-chemiluminescence (PCL) phenomenon was observed when phenothiazine medications were injected into the reaction mixture after the chemiluminescence (CL) reaction of luminol and potassium ferricyanide had finished. A possible reaction mechanism was proposed based on studies of the kinetic characteristics of the CL, CL spectra, fluorescence spectra, and on other experiments. The feasibility of determining various phenothiazine medications by utilizing these PCL reactions was examined. A molecular imprinting–post-chemiluminescence (MI-PCL) method was established for the determination of chlorpromazine hydrochloride using a chlorpromazine hydrochloride-imprinted polymer (MIP) as the recognition material. The method displayed high selectivity and high sensitivity. The linear range of the method was 1.0×10−8∼1.0×10−6, with a linear correlation coefficient of 0.9985. The detection limit was 3×10−9 g/ml chlorpromazine hydrochloride, and the relative standard deviation for a 1.0×10−7 g/ml chlorpromazine hydrochloride solution was 4.0% (n=11). The method has been applied to the determination of chlorpromazine hydrochloride in urine and animal drinking water with satisfactory results.   相似文献   

6.
A weak chemiluminescent (CL) emission was observed in the decomposition of peroxomonosulfate (HSO5-), which would be accelerated in the presence of trace amounts of cobalt (II). The mechanism was due to the production of singlet oxygen (1O2). Interestedly, riboflavin can enhance the CL and the CL intensity was strongly dependent on riboflavin concentration. Based on this phenomenon, a flow injection analysis (FIA) CL method was established for the determination of riboflavin. Additionally, the possible CL mechanism is proposed based on the kinetic curve of the CL reaction, CL spectra, UV-vis spectra and fluorescent spectra. The CL intensity was correlated linearly with concentration of riboflavin over the range of 1.0x10(-4) to 1.0x10(-8) g mL-1; the detection limit was 9.0x10(-9) g mL-1(S/N=3); the relative standard deviation was 1.4% for 9x10(-7) g mL-1 riboflavin (n=11). Furthermore, this method was applied to the determination of riboflavin in real tablets and injections successfully.  相似文献   

7.
A luminol-potassium ferricyanide-perphenazine CL reaction with high sensitivity for the determination of perphenazine was found. A perphenazine molecular imprinted polymer (MIP) was synthesized. Using the perphenazine MIP as a recognition material, a novel molecular imprinting-chemiluminescence (MI-CL) sensor for the determination of perphenazine was made based on the luminol-potassium ferricyanide-perphenazine CL reaction. The sensor displayed good selectivity and high sensitivity. The linear-response range of the sensor was 5.0 x 10(-8) - 1.0 x 10(-5) g/ml with a linear correlation coefficient of 0.9961. The detection limit was 2 x 10(-8) g/ml perphenazine and the relative standard deviation for 1.0 x 10(-6) g/ml perphenazine solution was 3.7% (n = 11). The sensor was applied to the determination of perphenazine in urine samples with satisfactory results.  相似文献   

8.
何云华  陈志红 《应用化学》2009,26(7):869-871
本文发现了异烟肼在铁氰化钾-钙黄绿素化学发光反应体系中的后化学发光反应。优化了反应条件,建立了一种利用后化学发光反应测定异烟肼的流动注射化学发光分析法。方法的检出限为6×10-8g/mL, 相对标准偏差为1.8% (2.0×10-6 g/mL 异烟肼,n=11),线性范围为2.0×10-7~1.0×10-5 g/mL。此法已用于异烟肼片剂中异烟肼含量的测定,结果与药典方法测定值一致。  相似文献   

9.
Huang Y  Chen Z 《Talanta》2002,57(5):953-959
A new chemiluminescence (CL) method is proposed for the determination of chlorpromazine hydrochloride, a drug often used to treat the psychiatric patients suffering from clinical depression. The method is based on the reaction between studied drug and Ce(IV) in a nitric acid medium and measurement of the CL intensity produced by rhodamine 6G used as a sensitizer. In the optimum conditions, CL intensities are proportional to concentrations of the studied drug over the range 0-1x10(-5) g ml(-1) with a detection limit of 6.5x10(-9) g ml(-1). The relative standard deviation (R.S.D.) is 4.1% for 1.5x10(-6) g ml(-1) chlorpromazine hydrochloride (n=11). The method has been applied to the determination of studied drug in tablets and biological fluids with satisfactory results.  相似文献   

10.
He Y  Lu J  Liu M  Du J 《The Analyst》2005,130(7):1032-1037
A new molecular imprinting-chemiluminescence method for the determination of trimethoprim was developed, in which trimethoprim-imprinted polymer was used as the molecular recognition material and the CL reaction of trimethoprim with potassium permanganate in acidic medium was used as the detection system. The CL intensity responds linearly to the concentration of trimethoprim within the 5.0 x 10(-8)-5.0 x 10(-6) g mL(-1) range (r= 0.9983) with a detection limit of 2 x 10(-8) g mL(-1). The relative standard deviation for the determination of 1.0 x 10(-7) g mL(-1) trimethoprim solutions is 4.8% (n= 9). The method has been applied to the determination of trimethoprim in pharmaceutical preparations and body fluids, and satisfactory results were obtained.  相似文献   

11.
Li S  Li X  Xu J  Wei X 《Talanta》2008,75(1):32-37
It was found that gold nanoparticles with different sizes could enhance the chemiluminescence (CL) of the luminol-NaIO4 system in alkaline solution. The most intensive CL signals were obtained with gold nanoparticles in diameter of 4 nm and the CL intensity increased linearly with the concentration of gold nanoparticles. The studies of UV-vis spectra, CL spectra, effects of concentrations of luminol and periodate solution were carried out to explore the CL enhancement mechanism. Catechol, hydroquinone and resorcinol were found to inhibit the CL signals of the luminol-NaIO4 reaction catalyzed by gold nanoparticles, which made it applicable for the determination of these polyphenols. Under the selected experimental conditions, the detection limits (3sigma) were in the range of 2.1 x 10(-9) to 1.0 x 10(-10) g ml(-1), the relative standard deviation (R.S.D., n=11) were in the range of 1.7-2.9%. The method has been successfully applied to the determination of catechol in tap water and synthesized samples with satisfactory results.  相似文献   

12.
Aly FA  Al-Tamimi SA  Alwarthan AA 《Talanta》2001,53(4):885-893
A new chemiluminescence (CL) method using flow injection has been described for the rapid and sensitive determination of three fluoroquinolone derivatives, namely ofloxacin, norfloxacin and ciprofloxacin hydrochloride. The method is based on the CL reaction of the studied fluoroquinolones with tris(2,2'-bipyridyl)ruthenium(II) [Ru(bipy)(3)(2+)] and Ce(IV) in sulfuric acid medium. Under the optimum conditions, the CL intensity is proportional to the concentration of the drugs in solution over the range 0.05-7.0 mug ml(-1) for norfloxacin, 0.05-6.0 mug ml(-1) for ciprofloxacin hydrochloride and 0.003-0.7 mug ml(-1) for ofloxacin. The limits of detection (s/n=3) were 3.1x10(-8) M norfloxacin, 2.6x10(-8) M ciprofloxacin hydrochloride and 5.5x10(-9) M ofloxacin. The method was applied successfully to the determination of these compounds in dosage forms and biological fluids.  相似文献   

13.
A simple, sensitive and selective chemiluminescence (CL) method was developed for the direct determination of aluminum (Al). This method is based on that the weak CL of cerium (IV)-calcein can be greatly enhanced by Al(III). The calibration curve was linear over the range 2.0 x 10(-10) to 4.0 x 10(-8)g mL(-1) with a detection limit of 8 x 10(-11)g mL(-1) (3sigma). The R.S.D. was 2.5% by 11 replicated determinations of 1.0 x 10(-9)g mL(-1) Al(III). The proposed method has been used to determine the concentration of Al(III) in real water samples with satisfactory results. The mechanism of the CL reaction was also discussed.  相似文献   

14.
《Analytical letters》2012,45(12):2475-2481
Abstract

A new chemiluminescence (CL) reaction was observed when cloperastine hydrochloride was injected into the reaction mixture after the CL reaction of Ce(IV) and sodium sulfite finished. A new flow injection CL method for the determination of cloperastine hydrochloride was established based on the CL reaction. The relative standard deviation (RSD) for the determination of cloperastine hydrochloride was 1.3% (n=11, c=1.0×10?6 g/mL). The CL intensity responded linearly to the concentration of cloperastine hydrochloride in the range 2.0×10?7~2.0×10?5 g/mL (r=0.9962). The detection limit was 5×10?8 g/mL cloperastine hydrochloride. The method had been applied to the determination of cloperastine hydrochloride in tablets with satisfactory results.  相似文献   

15.
A chemiluminescence (CL) method using flow injection (FI) has been investigated for the rapid and sensitive determination of enalapril maleate. The method is based on the CL reaction of the drug with tris(2,2'-bipyridyl)ruthenium(II), Ru(bipy)3(2+) and acidic potassium permanganate. After selecting the best operating parameters, calibration graphs were obtained over concentration ranges of 0.005-0.2 microg/ml and 0.7-100 microg/ml with a detection limit (S/N=2) of 1.0 ng/ml. The average % found was 99.9 +/- 0.7 and 100.2 +/- 0.3 for the two concentration ranges respectively. %RSD (n=10) for 5.0 microg/ml was 0.44. The method was successfully applied to the determination of enalapril maleate in dosage forms and biological fluids without interferences.  相似文献   

16.
A flow-injection (FI) methodology using tris(2,2'-dipyridyl)ruthenium(II), [Ru(dipy)3(2+)], chemiluminescence (CL) was developed for the rapid and sensitive determination of three thioxanthene derivatives, namely zuclopenthixol hydrochloride, flupentixol hydrochloride and thiothixene. The method is based on the CL reaction of the studied thioxanthenes with [Ru(dipy)3(2+)] and Ce(IV) in a sulfuric acid medium. Under the optimum conditions, calibration graphs were obtained over the concentration ranges 0.002-6 migrograms/ml for zuclopenthixol hydrochloride, 0.5-15 micrograms/ml for flupentixol hydrochloride and 0.05-7.5 micrograms/ml for thiothixene. The limits of detection (s/n = 3) were 4.2 x 10(-9) mol/l zuclopenthixol hydrochloride, 2 x 10(-8) mol/l flupentixol hydrochloride and 4.5 x 10(-8) mol/l thiothixene. The method was successfully applied to the determination of these compounds in dosage forms and biological fluids.  相似文献   

17.
Zhou Y  Nagaoka T  Li F  Zhu G 《Talanta》1999,48(2):461-467
A novel chemiluminescence (CL) system was evaluated for the determination of hydrogen peroxide, glucose and ascorbic acid based on hydrogen peroxide, which has a catalytic-cooxidative effect on the oxidation of luminol by KIO(4). Hydrogen peroxide can be directly determined by luminol-KIO(4)-H(2)O(2) CL system. The detection limit was 3.0x10(-8) mol l(-1) and the calibration graph was linear over the range of 2.0x10(-7)-6.0x10(-4) mol l(-1). The relative standard deviation of H(2)O(2) was 1.1% for 2.0x10(-6) mol l(-1) (N=11). Glucose was indirectly determined through measuring the H(2)O(2) generated by the oxidation of glucose in the presence of glucose oxidase at pH 7.6. The present method provides a source for H(2)O(2), which, in turn, coupled with the luminol-KIO(4)-H(2)O(2) CL reaction system. The CL was linearly correlated with glucose concentration of 0.6-110 mug ml(-1). The relative standard deviation was 2.1% for 10 mug ml(-1) (N=11). Detection limit of glucose was 0.08 mug ml(-1). Ascorbic acid was also indirectly determined by the suppression of luminol-KIO(4)-H(2)O(2) CL system. The calibration curve was linear over the range of 1.0x10(-7)-1.0x10(-5) mol l(-1) of ascorbic acid. The relative standard deviation was 1.0% for 8.0x10(-7) mol l(-1) (N=11). Detection limit of ascorbic acid was 6.0x10(-8) mol l(-1). These proposed methods have been applied to determine glucose, ascorbic acid in tablets and injection.  相似文献   

18.
基于纳米银能够增强鲁米诺-H2O2-呋喃硫胺体系化学发光的现象,建立了测定呋喃硫胺的流动注射化学发光新方法.对体系的化学发光机理进行了初步探讨,发现该体系的化学发光光谱的最大发射波长为425nm,该体系的发光体为激发态的3-氨基邻苯二甲酸根离子.该方法测定呋喃硫胺的线性范围为1.0×10-8~1.0×10-5g/mL,检出限4×10-9g/mL,对1.0×10-6g/mL呋喃硫胺连续9次测定的相对标准偏差(RSD)为1.9%.方法已用于药物呋喃硫胺片中呋喃硫胺的测定.  相似文献   

19.
高碘酸钾-鲁米诺体系中一些后化学发光反应的研究   总被引:1,自引:0,他引:1  
研究了葡醛内酯、盐酸美司坦和重酒石酸去甲肾上腺素等10种物质在高碘酸钾-鲁米诺体系中的后化学发光现象、后化学发光反应的动力学、化学发光光谱、荧光光谱以及其它相关性质, 提出了其可能的发光机理; 在优化的分析条件下建立了这10种物质的后化学发光分析方法, 初步构建了高碘酸钾-鲁米诺后化学发光分析体系.  相似文献   

20.
A novel and highly sensitive method for the determination of phenformin over the range of 6 x 10(-9) - 1 x 10(-5) g ml(-1) in pharmaceutical formulations with flow-injection chemiluminescence (CL) detection is proposed. The method is based on the CL produced during the oxidation of N-bromosuccinimide (NBS) in an alkaline medium in the presence of fluorescein as an effective energy transfer agent. The use of cetyltrimethylammonium bromide (CTAB) as a sensitizer enhances the signal magnitude by about 100 times. The detection limit is 2 x 10(-9) g ml(-1) (3sigma) with a relative standard deviation of 2.3% (n = 11) at 1 x 10(-7) g ml(-1) phenformin. Ninety samples can be determined per hour. The method was evaluated by carrying out a recovery study and by the analysis of commercial formulations. The obtained results compared well with those by an official method, and demonstrated good accuracy and precision. The possible CL mechanism of the proposed system was also briefly analyzed.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号