首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
A sensitive and precise stir bar sorptive extraction (SBSE) combined with LC (SBSE/LC) analysis is described for simultaneous determination of methyl, ethyl, propyl, and butyl parabens in commercial cosmetic products in agreement with the European Union Cosmetics Directive 76/768/EEC. Important factors in the optimization of SBSE efficiency are discussed, such as time and temperature of extraction, pH, and ionic strength of the sample, matrix effects, and liquid desorption conditions by different modes (magnetic stirring, ultrasonic). The LOQs of the SBSE/LC method ranged from 30 to 200 ng/mg, with linear response over a dynamic range, from the LOQ to 2.5 μg/mg, with a coefficient of determination higher than 0.993. The interday precision of the SBSE/LC method presented a coefficient of variation lower than 5%. The effectiveness of the proposed method was proven for analysis of commercial cosmetic products such as body creams, antiperspirant creams, and sunscreens.  相似文献   

2.
A method for mercury analysis and speciation in drinking water was developed, which involved stir bar sorptive extraction (SBSE) with in situ propyl derivatization and thermal desorption (TD)-GC-MS. Ten millilitre of tap water or bottled water was used. After a stir bar, pH adjustment agent and derivatization reagent were added, SBSE was performed. Then, the stir bar was subjected to TD-GC-MS. The detection limits were 0.01 ng mL(-1) (ethylmercury; EtHg), 0.02 ng mL(-1) (methylmercury; MeHg), and 0.2 ng mL(-1) (Hg(II) and diethylmercury (DiEtHg)). The method showed good linearity and correlation coefficients. The average recoveries of mercury species (n=5) in water samples spiked with 0.5, 2.0, and 6.0 ng mL(-1) mercury species were 93.1-131.1% (RSD<11.5%), 90.1-106.4% (RSD<7.8%), and 94.2-109.6% (RSD<8.8%), respectively. The method enables the precise determination of standards and can be applied to the determination of mercury species in water samples.  相似文献   

3.
冯利  张胜军  朱国华  李沐霏  刘劲松 《色谱》2017,35(4):466-471
基于搅拌棒吸附萃取(SBSE)技术建立了气相色谱-质谱测定地表水中16种多环芳烃(PAHs)的分析方法。该法采用多搅拌吸附棒同时富集,依次热脱附冷聚焦后进样的方式有效解决了搅拌棒吸附时间长、富集水样体积小等问题。优化后的结果表明,在0.2~10 ng/L范围内(萘为0.5~10 ng/L范围),16种PAHs的线性关系良好,相关系数(r)均0.99,方法检出限(MDL)为0.03~0.20 ng/L(萘为0.50 ng/L)。用该方法对钱塘江流域地表水进行测定,共检测出11种PAHs,含量为0.13~1.57 ng/L,不同添加水平下的加标回收率为75.6%~108.9%。该法可应用于地表水样品中该类物质的超痕量检测。  相似文献   

4.
A method for the determination of ultra-trace amounts of organochlorine pesticides (OCPs) in river water was developed by using stir bar sorptive extraction (SBSE) followed by thermal desorption and comprehensive two-dimensional gas chromatography coupled to high-resolution time-of-flight mass spectrometry (SBSE-TD-GC×GC-HRTOF-MS). SBSE conditions such as extraction time profiles, phase ratio (β: sample volume/polydimethylsiloxane (PDMS) volume), and modifier addition, were examined. Fifty milli-liter sample including 10% acetone was extracted for 3 h using stir bars with a length of 20 mm and coated with a 0.5 mm layer of PDMS (PDMS volume, 47 μL). The stir bar was thermally desorbed and subsequently analyzed by GC×GC-HRTOF-MS. The method showed good linearity over the concentration range from 50 to 1000 pg L(-1) or 2000 pg L(-1) for all analytes, and the correlation coefficients (r(2)) were greater than 0.9903 (except for β-HCH, r(2)=0.9870). The limit of detection (LOD) ranged from 10 to 44 pg L(-1). The method was successfully applied to the determination of 16 OCPs at pg L(-1) to ng L(-1) in river water. The results agree fairly well with the values obtained by a conventional liquid-liquid extraction (LLE)-GC-HRMS (selected ion monitoring: SIM) method using large sample volume (20 L). The method also allows screening of non-target compounds, e.g. pesticides and their degradation products, polyaromatic hydrocarbons (PAHs), polychlorinated biphenyls (PCBs), and pharmaceuticals and personal care products (PPCPs) and metabolites in the same river water sample, by using full spectrum acquisition with accurate mass in GC×GC.  相似文献   

5.
A method for the determination of seven alkylphenols and bisphenol A by stir bar sorptive extraction (SBSE) with in situ derivatization-thermal desorption (TD)-gas chromatography (GC)-mass spectrometry (MS) is described. SBSE was performed with in situ acetylation and without derivatization for comparison. For 4-tert-butylphenol and bisphenol A, in situ acetylation improved the responses in SBSE-TD-GC-MS. The method detection limits ranged from 0.1 to 3.2 ng/l. The recoveries of the analytes from a river water sample spiked with standards at 10 and 100 ng/l were 85.3-105.9% (R.S.D., 3.0-11.0%) and 88.3-105.8% (R.S.D., 1.6-8.3%), respectively.  相似文献   

6.
Analysis of wine primary aroma compounds by stir bar sorptive extraction   总被引:2,自引:0,他引:2  
A. Zalacain  G.L. Alonso 《Talanta》2007,71(4):1610-1615
Due to the great importance of some primary aroma compounds on wine quality, these compounds which includes terpenes, C13-norisoprenoids and C6 compounds, have been analyzed by stir bar sorptive extraction (SBSE) followed by a thermal desorption-gas chromatography-mass spectrometry analysis. The stir bar sorptive extraction method was optimized in terms of temperature, time, pH and NaCl addition. The best SBSE sorption kinetics for the target analytes were obtained after submitting the solutions to 60 °C during 90 min. The addition of sodium chloride did not enhance the volatile extraction. The method proposed showed good linearity over the concentration range tested, with correlation coefficients higher than 0.98 for all the analytes. The reproducibility and repeatability of the method was estimated between 0.22 and 9.11%. The detection and quantification limits of all analytes were lower than their respective olfactory threshold values. The application of this SBSE method revealed that monovarietal white wines were clearly separated by two canonic discriminating functions when grape varieties were used as differentiating variable, the first of which explained 98.4% of the variance. The compounds which contributed most to the differentiation were limonene, linalool, nerolidol and 1-hexanol.  相似文献   

7.
Lan L  Hu B  Yu C 《Journal of chromatography. A》2010,1217(45):7003-7009
An organic-inorganic hybrid titania-hydroxy-terminated silicone oil (titania-OH-TSO) stir bar coating was prepared by sol-gel method. The extraction performance of titania-OH-TSO coated stir bar was evaluated and compared with poly(dimethysiloxane) (PDMS), poly(dimethysiloxane)-divinylbenzene (PDMS-DVB), poly(dimethysiloxane)-β-cyclodextrin (PDMS-β-CD) and C(18) coated stir bar with five polar drugs of abuse including amphetamine (PA), methamphetamine (MA), 3,4-methylenedioxyamphetamine (MDA), 3,4-methylenedioxymethamphetamine (MDMA) and ketamine (Ke) as the model analytes. The experimental results revealed that the titania-OH-TSO coated stir bar exhibited highly pH-resistant ability, good preparation reproducibility, superior selectivity and high extraction efficiency for the target compounds. Based on this fact, a new method of titania-OH-TSO coated stir bar sorptive extraction (SBSE) combined with high performance liquid chromatography (HPLC)-ultraviolet visible (UV) detection was developed for the analysis of five drugs of abuse in urine samples. The factors affecting the extraction efficiency of SBSE such as sample pH, desorption solvent, sample volume, extraction time, desorption time, stirring rate and ionic strength were investigated and the optimal extraction conditions were established. Under the optimized conditions, the limits of detection (LODs) for titania-OH-TSO coated SBSE-HPLC-UV determination of five polar drugs of abuse were in the range of 2.3-9.1 μg/L with relative standard deviations (RSDs) ranging from 7.3 to 8.9% (c=300 μg/L, n=6), and all of the target compounds exhibited good linearity over a concentration range of 30-3000 μg/L. The developed method was applied to the determination of amphetamines and Ke in urine samples of drug abusers with satisfactory results.  相似文献   

8.
This work is the first study on the extraction efficiency of self‐doped polyaniline that is immobilized on the graphene‐modified magnetic nanoparticles. The new material was used as a sorbent for the magnetic solid‐phase extraction of methyl‐, propyl‐, and butylparabens. The use of graphene provides a high surface area and prevents aggregation of the nanoparticles. The self‐doped polyaniline also provides multifunctionality, high extraction capacity, and chemical stability even in the basic medium. The parabens were acetylated for determination by gas chromatography with flame ionization detection. The effects of monomer ratio, extraction solvent, sorbent amount, sample volume, desorption solvent volume, adsorption and desorption times, and sample ionic strength were optimized. Preconcentration factors obtained were from 190 to 310. The detection limits of the method were <2.8 μg/L. Linear ranges of the method were 5–2000 μg/L for propyl and butyl parabens, and 10–2000 μg/L for methyl paraben. The method was applied for the determination of the parabens in cosmetic products and extraction recoveries were 89–101% with RSDs ≤7.9%.  相似文献   

9.
Three environmentally friendly extraction techniques, membrane assisted solvent extraction (MASE), stir bar sorptive extraction (SBSE), and headspace solid phase microextraction (HS‐SPME), were compared for the direct analysis of the highly toxic rodenticide tetramine in food. The optimized MASE method was applied to seven foods fortified with tetramine and compared to previously reported SBSE and HS‐SPME results. Parameters such as the standard addition linearity (MASE (0.964–0.999), SBSE (0.966–0.999), HS‐SPME (0.955–0.999)), recovery (MASE (12–86%), SBSE (36–130%), HS‐SPME (50–200%)), reproducibility (MASE (3.0–30%), SBSE (4.4–9.6%), HS‐SPME (1–12%)), and LOD (MASE (1.6–6.4 ng/g), SBSE (0.2–2.1 ng/g), HS‐SPME (0.9–4.3 ng/g)) were compared.  相似文献   

10.
A simple and sensitive method for the determination of polar aromatic amines (PAAs) was developed using stir bar sorptive extraction (SBSE) coupling to high-performance liquid chromatography. A hydrophilic poly(vinylimidazole-divinylbenzene) (VIDB) monolithic material was prepared and acted as SBSE coating. The influences of polymerization conditions for VIDB on the extraction efficiency were investigated using aniline and 2,4-dinitroaniline as detected solutes. To achieve optimum extraction performance for PAAs, several parameters including extraction and desorption time, desorption solvent, ionic strength and pH value of sample matrix were investigated. The results showed that under the optimized experimental conditions, the method showed good sensitivity and excellent recoveries, as well as advantages such as linearity, simplicity, low cost and high feasibility. The extraction performance of present method to the target compounds also compared with commercial SBSE which using polydimethylsiloxane as coating and other SBSE which based on monolithic materials. Finally, the proposed method was successfully applied to the determination of PAAs in lake and sea waters, and excellent recoveries of spiked target compounds in real samples were obtained.  相似文献   

11.
利用自制的以聚(乙烯基咪唑-二乙烯基苯)(VIDB)整体材料为涂层的固相萃取搅拌棒(VIDB-SBSE)萃取3种硝基呋喃类药物,然后与高效液相色谱-二极管阵列检测器联用建立了测定饲料和水样品中硝基呋喃类药物残留的方法。详细考察了萃取过程中萃取和解吸时间、样品基质的pH值以及离子强度等实验条件对萃取效率的影响。在最佳条件下,呋喃唑酮的线性范围为0.5~200μg/L,呋喃妥因和呋喃西林的线性范围为0.25~200μg/L,3种目标物的检出限(LO D)(S/N=3)在0.068~0.11μg/L之间,所建方法具有理想的日内和日间重现性(R SD值均小于6%)。在对饲料和实际水样的测定中,不同加标浓度呋喃唑酮、呋喃妥因和呋喃西林的回收率在80.6%~108%之间。研究表明,所建立的方法具有简便、灵敏、环境友好等特点。  相似文献   

12.
We developed a CE and ultrasound‐assisted temperature‐controlled ionic liquid emulsification microextraction method for the determination of four parabens (methyl paraben, ethyl paraben, propyl paraben, and butyl paraben) in personal care products including mouthwash and toning lotion. In the proposed extraction procedure, ionic liquid (IL, 1‐octyl‐3‐methylimidazolium hexafluorophosphate) was used as extraction solvent, moreover, no disperser solvent was needed. Parameters affecting the extraction efficiency including volume of IL, heating temperature, ultrasonic time, extraction time, sample pH, ionic strength, and centrifugation time were optimized. Under the optimized conditions, the method was found to be linear over the range of 3–500 ng/mL with coefficient of determination (R2) in the range of 0.9990–0.9998. The LODs and LOQs for the four parabens were 0.45–0.72 ng/mL and 1.50–2.40 ng/mL, respectively. Intraday and interday precisions (RSDs, n = 5) were in the range of 5.4–6.8% and 7.0–8.7%, respectively. The recoveries of parabens at different spiked levels ranged from 71.9 to 119.2% with RSDs less than 9.5%.  相似文献   

13.
Cui H  Hua L  Hou K  Wu J  Chen P  Xie Y  Wang W  Li J  Li H 《The Analyst》2012,137(2):513-518
A home-made stir bar sorptive extraction (SBSE) apparatus was combined to a single photon ionization time-of-flight mass spectrometer (SPI-TOFMS) for rapid and sensitive determination of trace volatile organic compounds (VOCs) in water. The home-made SBSE bar, low-cost and disposable, was used for VOCs extraction. A thermal desorption (TD) device was designed to desorb the analytes from the SBSE bar, and a high throughput interface was developed to transfer the analytes into the ionization chamber of the SPI-TOFMS. The combination of large extraction volume of SBSE bar, and the direct measurement power of SPI-TOFMS enable a short analysis time for VOCs in water with high sensitivity, for example the limits of detection (LODs) were in the range of 7.4-11.1 ng L(-1) for benzene, toluene, and p-xylene (BTX) within 15 min. BTX aqueous solutions were chosen to demonstrate the quantitative capability, the linear range was from 0.05 to 100 μg L(-1) and the correlation coefficients were better than 0.996. The proposed method was successfully applied for the analysis of VOCs in urban river water.  相似文献   

14.
Kole PL  Millership J  McElnay JC 《Talanta》2011,85(4):1948-1958
A novel stir bar sorptive extraction (SBSE) method coupled with high performance liquid chromatography (HPLC) and UV detection for the extraction of diclofenac (DIC) from paediatric urine samples has been developed and validated. Selectivity and sensitivity being the prime objectives of the bioanalytical method for clinical samples, an optimised SBSE protocol was developed that selectively extracted DIC from various concurrently administered drugs. The validated assay was found to be linear (r = 0.9999) over a concentration range of 100-2000 ng mL−1. SBSE showed consistent recoveries (∼70%) of DIC across the validated linearity range. Overall, the method exhibited excellent accuracy and precision across all QC concentrations, tested over three days. Calculated LOD and LOQ were found to be 12.03 ng mL−1 and 36.37 ng mL−1, respectively, however, for the experimental purposes, 100 ng mL−1 was considered as the validated LOQ (accuracy and precision at this LQC was <20%). Further, studies on various attributes of the stir bar/SBSE, showed no significant inter- and intra-stir bar variability for DIC extraction. There was no carryover effect with re-use of conditioned stir bars and for the first time, a systematic investigation on the effect of ageing of stir bars on their extraction efficiency was carried out. Results showed that, for the present study, stir bars which were used 150 times were still functional based on in-house acceptance criteria and extraction efficiency. The validated method was successfully applied to the analysis of DIC in paediatric clinical trial samples.  相似文献   

15.
Yuling Hu 《Talanta》2010,82(2):464-4294
A novel stir bar coated with molecularly imprinted polymer (MIP) as selective extraction phase for sorptive extraction of triazine herbicides was developed. The stir bar was prepared by chemically bonding the MIP to the glass bar to improve its stability. A homogeneous and porous structure was observed on the stir bar surface. Extraction performance shows that the MIP-coated stir bar has stronger affinity to the template molecule terbuthylazine as compared with that of the reference stir bar without addition of template. Owning to the shape and structural compatibility, the obtained stir bar also demonstrated specific selectivity to the structural related-compounds of nine triazines, and thus can be applied to simultaneous determination of these compounds from complex samples coupled with high performance liquid chromatography. Four complex samples with different matrix, including rice, apple, lettuce and soil were used to evaluate this proposed method. The limits of detection obtained are in the range of 0.04-0.12 μg L−1, and the recoveries for the spiked rice, apple, lettuce and soil samples were 80.8-107.7%, 80.6-107.8%, 72.0-109.8% and 89.0-114.8% with RSD from 1.2 to 7.9%, respectively. Moreover, this MIP-coated stir bar was firm, durable and can be prepared simply and reproducibly. The developed coating method would be useful to prepare a range of selective stir bars in order to extend the applicability of stir bar sorptive extraction (SBSE) in complex sample analysis.  相似文献   

16.
A novel method based on ultrasonic solvent extraction and stir bar sorptive extraction (SBSE) for the analysis of 51 persistent organic pollutants including organochlorine pesticides (OCPs), polychlorinated biphenyls (PCBs), polycyclic aromatic hydrocarbons (PAHs), and polybrominated diphenylethers (PBDEs) in soil samples was developed. The different parameters that affect both the extraction of analytes from the soil samples, such as solvent selection, solvent volume, mass of soil, and extraction time, and the partitioning from the solvent/water mixture to the PDMS were studied. The final selected conditions consisted of the extraction of 1 g of soil with 15 mL methanol by sonication for 30 min. The methanol extract was mixed with 85 mL of Milli-Q water and extracted by means of SBSE for 14 h at 900 rpm. The stir bars were analyzed by thermal desorption-GC-mass spectometry (TD-GC-MS). The effects of the matrix on the recovery of the various pollutants under the developed method were studied using two soils with very different physicochemical properties. Method sensitivity, linearity, repeatability, and reproducibility were also studied. Validation and accuracy of the method were conducted by analyzing two commercial certified reference materials (CRMs). The main advantage of this method resides in the fact that a small amount of a nontoxic solvent (methanol) is needed for the extraction of only 1 g of solid sample allowing LODs ranging from 0.01 to 2.0 microg/kg. Repeatability and reproducibility variations were lower than 20% for all investigated compounds. Results of the CRMs verify the high accuracy of this method.  相似文献   

17.
利用相转换法制备了聚酰亚胺吸附萃取搅拌棒,用5种有机酚作为评价标样,并与现有商品化吸附萃取搅拌棒进行比较。优化了萃取搅拌速度、溶液离子强度、萃取温度、萃取时间以及热解析温度和时间。在最佳实验条件下,100 mL 样品,30% NaCl,在25℃下,经活化5 min 后的聚酰亚胺吸附搅拌棒萃取30 min (800 r/ min),然后300℃热解析4 min,使目标物脱附,再进行色谱分析。目标物在大于两个数量级浓度范围内具有良好的线性(R≥0.9995),定量限(LOQ,S/ N=10)为0.028~0.123μg/ L,重复性为1.6%~9.7%。将SBSE 与气相色谱-质谱联用,对海水、自来水和污水中的酚类进行定性与定量分析,结果表明,聚酰亚胺吸附萃取搅拌棒具有良好的选择性,最高热解析温度350℃,在分析水中痕量极性化合物领域具有广阔应用前景。  相似文献   

18.
包月  翟怡鑫  宁涛  陈品  朱书奎 《色谱》2022,40(11):1005-1013
建立了一种基于共价有机框架材料的磁固相萃取-高效液相色谱方法,用于环境水样中对羟基苯甲酸酯的快速灵敏分析。首先以Fe3O4纳米粒子为磁核,通过1,3,5-苯三甲醛(Tb)和联苯胺(Bd)在室温下的席夫碱反应合成了磁性共价有机框架材料——Fe3O4@TbBd,通过扫描电镜、热重分析、X射线衍射和振动样品磁强计等表征手段证明了该磁性共价有机框架材料具有良好的热稳定性和化学稳定性,且磁响应强度较大,是用于磁固相萃取的理想材料。随后系统研究了影响萃取效率的因素,包括吸附剂用量、萃取时间、pH、解吸溶剂、解吸时间和解吸次数,建立了基于Fe3O4@TbBd的磁固相萃取-高效液相色谱测定环境水样中4种对羟基苯甲酸酯的方法。方法的线性范围良好,4种目标物的检出限和定量限范围分别为0.2~0.4 μg/L和0.7~1.4 μg/L,加标回收率为86.1%~110.8%,日内和日间精密度的相对标准偏差(RSD)分别低于5.5%和4.9%。最后将该方法应用于东湖水、长江水和生活废水中对羟基苯甲酸酯的测定,不同加标水平下对羟基苯甲酸酯的回收率在80.7%~117.5%之间,RSD在0.2%~8.8%之间。该方法操作简单,萃取时间短,灵敏度较高且对环境友好,在环境水样中对羟基苯甲酸酯的检测方面有良好的应用潜力。  相似文献   

19.
A novel analytical method has been developed for the determination of 4-tert.-octylphenol (OP) and 4-nonylphenol (NP) in laboratory animal feed samples, which involves stir bar sorptive extraction (SBSE) followed by liquid desorption (LD) and column-switching liquid chromatography-mass spectrometry (CS-LC-MS) with solid-phase extraction (SPE). The method required correction by stable isotopically labeled surrogate standards, deuterium 4-tert.-octylphenol (OP-d) and [2H5] 4-(1-methyl)octylphenol (m-OP-d5). A feed sample was homogenized with methanol by ultrasonication. After centrifugation, the supernatant was subjected to extraction for 120 min at room temperature (25 degrees C) using a stir bar coated with polydimethylsiloxane. After the extraction, the analyte was desorbed from the stir bar by LD using acetonitrile. Then, the liquid sample was analyzed by CS-LC-MS with SPE. The average recoveries from laboratory feed samples spiked with OP and NP at 20 ng g(-1) were 99.5 and 103.8%, respectively, with correction using the added surrogate standards. The limits of quantification were 1 ng g(-1) for OP and 5 ng g(-1) for NP in feed sample. The measurement of OP and NP in commercial laboratory animal feed samples resulted in the detection of sub ng g(-1) NP  相似文献   

20.
A novel method called thermal desorption (TD) with in tube silylation followed by gas chromatography-mass spectrometry (GC-MS), which is used for the determination of trace amounts of alkylphenols (APs) in river water samples, is described. APs are extracted from river water samples and concentrated by the stir bar sorptive extraction (SBSE) technique. The stir bar coated with polydimethylsiloxane (PDMS) is added to 2.0 ml water sample and stirring is carried out for 60 min at room temperature (25 degrees C) in the vial. Then, the PDMS stir bar is subjected to TD with in tube silylation followed by GC-MS. The detection limit is of the sub pg ml(-1) (ppt) level. The method shows good linearity and the correlation coefficients are higher than 0.99 for all analytes. The average recoveries of APs are higher than 90% (R.S.D.: 3.6-14.8%, n=6). This simple and sensitive analytical method may be used in the determination of trace amounts of APs in river water samples.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号