首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
A simple and rapid reversed-phase liquid chromatographic method was developed for the related substances determination and quantitative evaluation of ziprasidone hydrochloride, which is used as an antipsychotic agent. Forced degradation studies were performed on bulk sample of ziprasidone hydrochloride using acid, base, oxidative hydrolysis, thermal stress and photolytic degradation. Mild degradation of the drug substance was observed during thermal stress and considerable degradation observed during base hydrolysis. The chromatographic method was fine tuned using the samples generated from forced degradation studies. Good resolution between the peaks corresponds to synthetic impurities and degradation products from the analyte were achieved on YMC Pack Pro C18 column using the mobile phase consists of a mixture of 0.05% v/v of phosphoric acid in water and acetonitrile. The stressed test solutions were assayed against the qualified working standard of ziprasidone hydrochloride and the mass balance in each case was close to 99.7% indicating that the developed method was stability-indicating. Validation of the developed method was carried out as per ICH requirements.  相似文献   

2.
A validated, specific, stability-indicating reversed-phase liquid chromatographic method has been developed for quantitative analysis of moxifloxacin and its related substances in bulk samples and pharmaceutical dosage forms in the presence of degradation products and process-related impurities. Forced degradation studies were performed on bulk samples of moxifloxacin, in accordance with ICH guidelines, using acidic, basic, and oxidizing conditions, and thermal and photolytic stress, to show the stability-indicating power of the method. Significant degradation was caused by oxidative stress and by basic conditions; no degradation was observed under the other stress conditions. The method was optimized by analysis of the samples generated during the forced degradation studies and sample solutions spiked with the impurities. Good resolution between the analyte peak and peaks corresponding to process-related impurities and degradation products was achieved on a C18 column with a simple linear mobile phase gradient prepared from aqueous sodium dihydrogen orthophosphate dihydrate containing triethylamine, pH adjusted to 3.0 with orthophosphoric acid, and methanol. Detection was performed at 240 nm. Limits of detection and quantification were established for moxifloxacin and its process related impurities. When the stressed test solutions were assayed against moxifloxacin working standard solution the mass balance was always between 99.3 and 100.1%, indicating the method was stability-indicating. The method was validated in accordance with ICH guidelines, and found to be suitable for checking the quality of bulk samples of moxifloxacin at the time of release of a batch and during storage (long term and accelerated stability testing was conducted).  相似文献   

3.
A validated, specific, stability-indicating reversed-phase liquid chromatographic method has been developed for quantitative analysis of gatifloxacin, its degradation products, and its process-related impurities in bulk samples and in pharmaceutical dosage forms. Forced degradation of gatifloxacin bulk sample was conducted in accordance with ICH guidelines. Acidic, basic, neutral, and oxidative hydrolysis, thermal stress, and photolytic degradation were used to assess the stability-indicating power of the method. Substantial degradation was observed during oxidative hydrolysis. No degradation was observed under the other stress conditions. The method was optimized using samples generated by forced degradation and sample solution spiked with impurities. Good resolution of the analyte peak from peaks corresponding to process-related impurities and degradation products was achieved on a C18 column by use of a simple linear mobile-phase gradient prepared from mixtures of acetonitrile and an aqueous solution of sodium dihydrogen orthophosphate dihydrate and triethylamine adjusted to pH 6.5 with orthophosphoric acid. Detection was performed at 240 nm. Limits of detection and quantification were established for gatifloxacin and its process-related impurities. When the stressed test solutions were assayed by comparison with gatifloxacin working standard the mass balance was always close to 99.3%, indicating the method was stability-indicating. Validation of the method was performed in accordance with ICH requirements. The method was found to be suitable for checking the quality of bulk samples of gatifloxacin at the time of batch release and also during storage.  相似文献   

4.
The present paper describes the development of a stability indicating reversed phase column liquid chromatographic method for aripiprazole in the presence of its impurities and degradation products generated from forced decomposition studies. The drug substance was subjected to stress conditions of aqueous hydrolysis, oxidative, photolytic and thermal stress degradation. The degradation of aripiprazole was observed under acid hydrolysis and peroxide. The drug was found to be stable to other stress conditions attempted. Successful separation of the drug from the synthetic impurities and degradation products formed under stress conditions was achieved on an Inertsil phenyl column using a mixture of 0.2% trifluoroacetic acid and acetonitrile (55:45, v/v). The developed LC method was validated with respect to linearity, accuracy, precision, specificity and robustness. The assay method was found linear in the range of 25–200 μg mL?1 with a correlation coefficient of 0.9999 and the linearity of the impurities were established from LOQ to 0.3%. Recoveries of the assay and impurities were found between 97.2 and 104.6%. The developed LC method for the related substances and assay determination of aripiprazole can be used to evaluate the quality of regular production samples. It can also be used to test the stability samples of aripiprazole. To the best of our knowledge, the validated stability indicating LC method which separates all the impurities disclosed in this investigation was not published elsewhere.  相似文献   

5.
6.
A gradient reversed-phase liquid chromatographic assay was developed for the quantitative determination of the non-steroidal anti-inflammatory drug valdecoxib. The developed method was also applicable to the determination of related substances in the bulk drug. Forced degradation studies were performed on bulk valdecoxib using acid (2.0 N hydrochloric acid), base (2.0 N sodium hydroxide), oxidation (6.0% v/v hydrogen peroxide), water hydrolysis, heat (60 °C) and photolysis. Mild degradation was observed using alkaline conditions and considerable degradation observed during oxidative stress. Chromatographic separation of process-related impurities and degradation products was achieved using a 5 micron Zorbax SB-CN LC column. The mobile phase consisted of aqueous potassium dihydrogen phosphate (pH 3.0) and acetonitrile. Stressed samples were assayed using the developed LC method and determination of the mass balance accounted for 99.5%, thus indicating the suitability of this stability-indicating method. Linearity, accuracy, precision and robustness have also been evaluated.  相似文献   

7.
A simple reverse phase liquid chromatographic method was developed for the quantitative determination of desipramine hydrochloride and its related impurities in bulk drugs which is also stability-indicating. During the forced degradation at hydrolysis, oxidative, photolytic and thermal stressed conditions, the degradation results were only observed in the oxidative stress condition. The blend of the degradation product and potential impurities were used to optimize the method by an YMC Pack Pro C18 stationary phase. The LC method employs a linear gradient elution with the water–acetonitrile–trifluoroacetic acid as mobile phase. The flow rate was 1.0 mL min?1 and the detection wavelength 215 nm. The stressed samples were quantified against a qualified reference standard and the mass balance was found close to 99.0% (w/w) when the response of the degradant was considered to be equal to the analyte (i.e. desipramine). The developed RP-LC method was validated in agreement with ICH requirements.  相似文献   

8.

A simple reverse phase liquid chromatographic method was developed for the quantitative determination of desipramine hydrochloride and its related impurities in bulk drugs which is also stability-indicating. During the forced degradation at hydrolysis, oxidative, photolytic and thermal stressed conditions, the degradation results were only observed in the oxidative stress condition. The blend of the degradation product and potential impurities were used to optimize the method by an YMC Pack Pro C18 stationary phase. The LC method employs a linear gradient elution with the water–acetonitrile–trifluoroacetic acid as mobile phase. The flow rate was 1.0 mL min−1 and the detection wavelength 215 nm. The stressed samples were quantified against a qualified reference standard and the mass balance was found close to 99.0% (w/w) when the response of the degradant was considered to be equal to the analyte (i.e. desipramine). The developed RP-LC method was validated in agreement with ICH requirements.

  相似文献   

9.
A forced degradation study was successfully applied for the development of a stability-indicating assay method for the determination of atazanavir in presence of its degradation products. The method was developed and optimized by analyzing the forcefully degraded samples. Degradation of the drug was done under acidic, alkaline, oxidative, photolytic and thermal stress conditions. The proposed method was able to resolve all of the possible degradation products formed during the stress studies. The major impurities are generated in acidic and alkaline conditions. The product was found stable under thermal, photolytic and oxidative conditions. The developed method was validated for determination of atazanavir, and the method was found to be equality applicable to study the impurities formed during routine and forced degradation of atazanavir.  相似文献   

10.
A forced degradation study was successfully applied for the development of a stability-indicating assay method for determination of rosuvastatin Ca in the presence of its degradation products. The method was developed and optimized by analyzing the forcefully degraded samples. Degradation of the drug was done at various pH values. Moreover, the drug was degraded under oxidative, photolytic, and thermal stress conditions. Mass balance between assay values of degraded samples and generated impurities was found to be satisfactory. The proposed method was able to resolve all of the possible degradation products formed during the stress study. The developed method was successfully applied for an accelerated stability study of the tablet formulation. The major impurities generated during the accelerated stability study of the tablet formulation were matches with those of the forced degradation study. The developed method was validated for determination of rosuvastatin Ca, and the method was found to be equally applicable to study the impurities formed during routine and forced degradation of rosuvastatin Ca.  相似文献   

11.
Macitentan (MAC) is a pulmonary arterial hypertension (PAH) drug marketed as a tablet and often has stability issues in the final dosage form. Quantitative determination of MAC and its associated impurities in tablet dosage form has not been previously reported. This study quantified impurities present in Macitentan tablets using a binary solvent-based gradient elution method using reversed phase-high performance liquid chromatography. The developed method was validated per International Conference on Harmonization (ICH) guidelines and the drug product was subjected to forced degradation studies to evaluate stability. The developed method efficiently separated the drug and impurities (48 min) without interference from solvents, excipients, or other impurities. The developed method met all guidelines in all characteristics with recoveries ranging from 85%-115%, linearity with r2 ≥ 0.9966, and substantial robustness. The stability-indicating nature of the method was evaluated using stressed conditions (hydrolysis:1 N HCl at 80℃/15 min; 1 N NaOH at 25℃/45 min; humidity stress (90% relative humidity) at 25℃ for 24 h, oxidation:at 6% (v/v) H2O2, 80℃/15 min, thermolysis:at 105℃/16 h and photolysis:UV light at 200 Wh/m2; Fluorescent light at 1.2 million luxh). Forced degradation experiments showed that the developed method was effective for impurity profiling. All stressed samples were assayed and mass balance was>96%. Forced degradation results indicated that MAC tablets were sensitive to hydrolysis (acid and alkali) and thermal conditions. The developed method is suitable for both assay and impurity determination, which is applicable to the pharmaceutical industry.  相似文献   

12.
A novel stability-indicating high-performance liquid chromatographic (HPLC) method was developed and validated for assay and determination of impurities of emtricitabine in drug substance. Emtricitabine was found to be degraded under acidic, alkaline, and oxidative stress conditions and to be more labile under oxidative conditions. The drug proved to be stable to dry heat and photolytic degradation. Resolution of major and minor degradation impurities was achieved on an Intersil ODS-3V column utilizing 10 mM sodium phosphate buffer and methanol (85:15) as mobile phase. Detection was at 280 nm. Validation studies were performed as per ICH recommended conditions. The developed method was found to be linear, accurate, specific, selective, precise, and robust.  相似文献   

13.
A stability indicating RP-HPLC method for cephalexin has been developed and validated to identify and characterize potential degradation products. Drug was subjected to hydrolytic (acidic, basic, and neutral), oxidative, thermal, and photolytic stresses as per ICH guidelines Q1A (R2) and Q1B. Chromatographic separation was achieved on C8 column with mixture of ammonium acetate buffer pH 4.5 and acetonitrile in gradient mode as a mobile phase with PDA detection. Specificity of the method was established by peak purity studies. Method was validated as per ICH guideline Q2 (R1) for accuracy, precision, linearity, sensitivity, and robustness. Kinetics for each degradation condition was studied with respect to order of reaction and rate constant. Method was found to comply with acceptance criteria of validation parameters with respect to specificity (peak purity greater than 0.999) linearity (r 2 greater than 0.99), accuracy (% recovery in the range of 98–102%), and precision (% RSD not more than 2). A total of six degradation products were generated in different stress conditions; these were identified and structures were proposed using LC–MS/MS. Cephalexin undergoes degradation in almost all the conditions. The developed stability indicating method is suitable for analysis of stability samples as it adequately separates all degradation products. Degradation products generated in photolytic and oxidative conditions are reported for the first time.  相似文献   

14.
A novel stability indicating LC method was developed and validated for the quantitative determination of riluzole in bulk drugs and in pharmaceutical dosage forms in the presence of its isomers, related substances and degradation products. The drug was subjected to stress conditions of hydrolysis (acid, base and neutral), oxidation, photolysis and thermal degradation. Considerable degradation was observed under base hydrolysis and oxidation. The stress samples were assayed against a qualified reference standard and the mass balance was found close to 99.5%. The developed method was validated with respect to linearity, accuracy, precision, specificity, ruggedness and robustness.  相似文献   

15.
The present paper describes stability indicating reverse phase high-performance liquid chromatography (RP-HPLC) assay method for nitazoxanide in bulk drugs. The developed method is also applicable for the related substances determination in bulk drug. The drug substance was subjected to stress conditions of hydrolysis, photolysis and thermal degradation. The considerable degradation of nitazoxanide was observed under base and peroxide hydrolysis. The drug was found to be stable in other stress conditions attempted. The chromatographic separation of the drug was achieved on reversed-phase C-18 column. Eluents were monitored on photo-diode array detector at a wavelength of 240 nm. The mobile phase was aqueous 0.005 M tetra butyl ammonium hydrogen sulphate and acetonitrile (45:55, v/v). In the developed HPLC method, resolution between nitazoxanide and its potential impurities, namely Imp-A (5-nitro-1,3-thiazol-2-amine), Imp-B (N-(5-nitro-1,3-thiazol-2-yl) acetamide) and Imp-C (2-{[(5-nitro-1,3-thiazol-2-yl) amino] carbonyl} phenyl 2-(acetyloxy) benzoate) was found greater than three. The developed RP-HPLC method was validated with respect to response function, accuracy, precision, specificity, stability of analytical solutions and robustness. Also to determine related substances and assay determination of nitazoxanide that can be used to evaluate the quality of regular production samples. The developed method can also be conveniently used for the assay determination of nitazoxanide in pharmaceutical formulations.  相似文献   

16.
A simple, inexpensive and rapid isocratic LC method has been developed for the quantative determination of Rimonabant, an anti-obesity drug. The method can also be employed for the determination of Rimonabant and its impurities in the bulk drug. Degradation studies were performed on the bulk drug by heating to 60 °C, exposure to UV light at 254 nm, acid (0.5 N hydrochloric acid), base (0.5 N sodium hydroxide) and aqueous hydrolysis and oxidation with 3.0% v/v hydrogen peroxide. Considerable degradation was observed under oxidation conditions. Good resolution between the peaks corresponding to impurities produced during synthesis, degradation products and the analyte was achieved on a Phenomenex Gemini C18 LC column using a mobile phase consisting of a mixture of aqueous potassium dihydrogen phosphate (pH 3.0) and acetonitrile. The degradation samples were assayed against the reference standard of Rimonabant and the mass balance in each case was close to 99.5%. Validation of the method was carried out as per ICH requirements.  相似文献   

17.
An isocratic reverse phase liquid chromatographic (RP-LC) assay method has been developed for the quantitative determination of nateglinide and its related components namely imp-1 and imp-2 in bulk drug and in pharmaceutical dosage form, used for the treatment of type II diabetes mellitus. The developed method is stability indicating and also can be used for stability testing. The chromatographic separation was achieved on C-8, 150 × 4.6 mm, 3.5 μm stationary phase. The LC method employs solution A as mobile phase. Solution A contains a mixture of phosphate buffer pH 3.0: acetonitrile (50:50 v/v). The flow rate was 1.0 mL min−1 and the detection wavelength was 210 nm. In the developed LC method the resolution between nateglinide and its potential impurities namely imp-1 and imp-2 was found to be greater than 5.0. The drug was subjected to stress conditions of hydrolysis, oxidation, photolysis and thermal degradation. Considerable degradation was found to occur in acid medium, alkaline medium and oxidative stress conditions. The stress samples were assayed against a qualified reference standard and the mass balance was found close to 99.2%. The developed RP-LC method was validated with respect to linearity, accuracy, precision and robustness.  相似文献   

18.
A novel, stability-indicating gradient reverse-phase ultra-performance liquid chromatographic method was developed for the simultaneous determination of ibuprofen and diphenhydramine citrate in the presence of degradation products and process related impurities in combined dosage form. The method was developed using C18 column with mobile phase containing a gradient mixture of solvent A and B. The eluted compounds were monitored at 220 nm. Ibuprofen and diphenhydramine citrate were subjected to the stress conditions of oxidative, acid, base, hydrolytic, thermal, and photolytic degradation. Major unknown impurity formed under oxidative degradation was identified using LC-MS-MS study. The developed method was validated as per ICH guidelines with respect to specificity, linearity, limit of detection, limit of quantitation, accuracy, precision and robustness. The described method was linear over the range of 0.20-6.00 μg/mL (r>0.998) for Ibuprofen and 0.084-1.14 μg/mL for diphenhydramine citrate (r>0.998). The limit of detection results were ranged from 0.200-0.320 μg/mL for ibuprofen impurities and 0.084-0.099 μg/mL for diphenhydramine citrate impurities. The limit of quantitation results were ranged from 0.440 to 0.880 μg/mL for ibuprofen impurities and 0.258 to 0.372 μg/mL for diphenhydramine citrate impurities. The recovery of ibuprofen impurities were ranged from 98.1% to 100.5% and the recovery of diphenhydramine citrate impurities were ranged from 97.5% to 102.1%. This method is also suitable for the simultaneous assay determination of ibuprofen and diphenhydramine citrate in pharmaceutical dosage forms.  相似文献   

19.
A novel liquid chromatographic method has been developed, and validated for the determination of tolterodine tartarate, for its potential three impurities in drug substances and drug products. Efficient chromatographic separation was achieved on a C8 stationary phase (150 × 4.6 mm, 3.5 μm particles) with a simple mobile phase combination delivered in an isocratic mode at a flow rate of 0.8 mL min?1 and quantitation was carried out using ultraviolet detection. Microwave assisted degradation procedure was employed for stress testing studies in addition to the conventional way of a refluxing method. The results of both studies were compared. In the developed LC method, the resolution between tolterodine and its three potential impurities was found to be greater than 2.0. Regression analysis shows an r value (correlation coefficient) greater than 0.999 for tolterodine and for its three impurities. This method was capable to detect all three impurities of tolterodine at a level below 0.0038% with respect to a test concentration of 0.5 mg mL?1 for a 10 μL injection volume. The inter- and intra-day precisions for all three impurities and for tolterodine were found to be within 1.1% RSD at its specification level. The method has shown good, consistent recoveries for tolterodine (98.9–101.6%) and for its three impurities (94.5–103.0%). The test solution was found to be stable in the diluent for 48 h. The drug was subjected to stress conditions of hydrolysis, oxidation, photolysis and thermal degradation, as prescribed by ICH. Degradation was found to occur in alkaline stress condition, while the drug was stable to water hydrolysis, acid hydrolysis, oxidative stress, photolytic and thermal stress. The assay of stressed samples was calculated against a qualified reference standard and the mass balance was found close to 99.5%. Microwave degradations were very fast and comparable to the conventional way of the refluxing method. Robustness studies were carried out and suggested that system suitability parameters were unaffected by small changes in critical factors. The validated method was successfully applied for the determination of tolterodine tartarate in drug substances and drug products.  相似文献   

20.
A simple, sensitive isocratic rapid resolution liquid chromatographic assay method has been developed for the quantitative determination of quetiapine hemifumarate in bulk active pharmaceutical ingredient, used for the treatment of schizophrenia. The developed method is also applicable for the process related impurities determination. Efficient chromatographic separation was achieved on a C18 stationary phase with simple mobile phase combination delivered in a isocratic mode and quantification was by ultraviolet detection at 225 nm at a flow rate of 1.0 mL min?1. In the developed LC method the resolution between quetiapine hemifumarate and its three potential impurities was found to be greater than 2.0. Regression analysis showed an r value (correlation coefficient) greater than 0.99 for quetiapine hemifumarate and its three impurities. This method was capable to detect all three impurities of quetiapine hemifumarate at a level of 0.003% with respect to test concentration of 1.0 mg mL?1 for a 3 μL injection volume. The bulk active pharmaceutical ingredient was subjected to stress conditions of hydrolysis, oxidation, photolysis and thermal degradation. Considerable degradation was found to occur in oxidative stress conditions. The stress samples were assayed against a qualified reference standard and the mass balance was found close to 99.5%. The developed RR-LC method was validated with respect to linearity, accuracy, precision and robustness.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号