首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 0 毫秒
1.
The lack of reliable, certified calibrant solutions for the Fusarium mycotoxins deoxynivalenol (DON), 3-acetyl-DON (3-Ac-DON), 15-acetyl-DON (15-Ac-DON) and nivalenol (NIV) is a serious drawback in the already problematic area of trichothecene analysis. For this reason, purified DON, 3-Ac-DON, 15-Ac-DON and NIV standards were processed, the conditions required for their isolation and purification were optimised, and the crystalline toxins were thoroughly characterised. Several complimentary analytical methods were used to evaluate the identities of the mycotoxins and the types and amounts of impurities; results obtained from 1 H and 13 C NMR spectra, as well as from IR-spectra, were in agreement with the literature. Elemental analysis revealed that the isolated NIV occurs as monohydrate. If this is not known it results in a weighing error of approximately 5%. Differential scanning calorimetry (DSC) was only successful for 15-Ac-DON, as the other trichothecenes decomposed during measurements. No traces of chloride, nitrate and sulphate were found by means of ion chromatography (IC). As expected UV absorption spectra for DON, NIV, 3-Ac-DON and 15-Ac-DON yielded max values of 216, 217, 217 and 219 nm, respectively. Minor peaks due to impurities were observed by high performance liquid chromatography (HPLC) with UV detection. The main impurity peak in the DON sample was identified by LC-tandem mass spectroscopy (LC-MS/MS) as 4,7-dideoxy-NIV (7-deoxy-DON), which occurs at levels of approximately 1.4%. Gas chromatography (GC) was performed, coupled with either an electron capture detector (ECD), a flame ionisation detector (FID), or a mass spectrometric detector (MS); however, derivatisation prior to GC analysis makes the estimation of impurities difficult. LC-MS/MS was found to be unsuitable for quantifying levels of impurities. It can be concluded that high-purity (>97%) B-trichothecene standards were successfully processed and fully characterised for the first time.Dedicated to the memory of Wilhelm Fresenius  相似文献   

2.
《Analytical letters》2012,45(14):1249-1260
Abstract

Kinetic analysis using complex formation reactions is applied to “mixtures” containing (variously), Fe3+, Fe2+, iron complexed to a fulvic acid, hydrous oxide colloids, and non-settleable particulate iron. Such mixtures can be directly resolved if the kinetics of complex formation reactions are pseudo first order and differences among rate constants are large enough. At pH = 4, it is found that fulvic acid causes substantial reduction of Fe3+ to Fe2+ and that it causes complete dissolution and depolymerization of colloidal and particulate iron at 1:1 ratio. Addition of one equivalent of phosphate causes precipitation of ferric phosphate even in the presence of fulvic acid. This system is very useful for modeling natural water because the kinetic technique allows convenient analysis of components of varying particle size. The present results are strongly indicative of the role of fulvic acid in mediating metal ion chemistry in natural water.  相似文献   

3.
The comparative studies of Pb and Cd adsorption to the surface coatings (Fe, Mn, AI oxides, organic materials, and associated minerals), which were developed on glass slides in five natural and two technical waters (plant effluents), were carried out under controlled |aboratory conditions(mineral salts solution with defined speciation, ionic strength 0.05 mol/L, 25 ℃ and pH 6. 0). The classical Langmuir adsorption isotherm was applied to estimating the equilibrium coefficients of Pb and Cd adsorption to the surface coat-ings. The results show that the maximum adsorption of Pb and Cd to the surface coatings mentioned above varied widely. There was a systemic increase in the maximum adsorption of Pb and Cd to the surface coatings with increasing the contents of Mn and Fe oxides in the surface coatings in significant correlation, respective-ly, not only highlighting the relative importance of the metal oxide fraction for Pb and Cd adsorption to the surface coatings developed in natural and technical water samples, but also implying the same adsorption mechanisms of Pb and Cd to the surface coatings developed both in natural and technical water samples.  相似文献   

4.
The current situation in the pharmaceutical industry is discussed, when the traceability of measurement (analytical) results to certified values of pharmacopoeial reference standards is required, without evaluating their uncertainties. It is shown that the evaluation of measurement uncertainty is necessary for understanding the level of confidence of the analytical results and their comparability, particularly during preparation and characterisation of the reference standards.Papers published in this section do not necessarily reflect the opinion of the Editors, the Editorial Board and the Publisher. Apart from exceptional circumstances, they are not submitted to the usual referee procedure and go essentially unaltered.  相似文献   

5.
 Working group 5 of EuraChem Nederland has developed a framework for the implementation of reference materials in analytical chemistry. In this discussed paper, the framework is proposed as a tool for the development of standard operation procedures (SOPs) in laboratories. The implementation of (certified) reference materials in these SOPs is of major importance in establishing comparability and traceability in measurement results, which in turn play a crucial role in measurement in support of trade, environmental issues, and characterisation of materials. Recent developments in the field of uncertainty analysis require the application of reference materials. It is recognised that the calculation of the combined measurement uncertainty becomes almost impossible without the use of certified reference materials with a stated uncertainty. Received: 1 December 1995 Accepted: 20 December 1995  相似文献   

6.
 Economic and technological change, regional and international trade and the globalisation of industry have led to intense pressures for improvements to analytical quality, reliability and comparability. Of central importance are national traceability structures connecting chemical measurements in the field with internationally accepted measurement units and their practical realisations. Australia has a developed physical and engineering measurement system, a legislative framework for analytical traceability and, in the National Association of Testing Authorities, a recognised laboratory accreditation system. The need has been identified to develop the technical capability to perform matrix-independent reference measurements for the certification of traceable reference materials, useable as practical analytical etalons to establish metrological control systems in field measurements for amounts of substance. Recently, a unique collaborative consortium has proposed a National Analytical Reference Laboratory (NARL). The NARL is designed to be a metrological mass spectrometry facility for the transference of measurement units to more widely useable chemical measurement standards and reference materials. Received: 10 October 1995 Accepted: 26 October 1995  相似文献   

7.
Foodstuffs shall not contain pathogenic micro-organisms in concentrations which may cause a risk for consumer health. The relevant legislation therefore normally contains the requirement that these organisms are absent in a certain product quantity (e.g. 25 g). It is not at all easy to prove the absence. Reference materials are important tools for checking the performance of qualitative methods. These materials should contain the target organism in low numbers (close to 1 cell/capsule). Furthermore, the most important interfering micro-organisms should be taken into consideration, when testing the performance of detection methods using reference materials. When developing reference materials with the described characteristics, detection methods are needed which give a positive result with one or a few cell(s) of the target organism. While these requirements appear to be fairly obvious, precise statements on method performance are rarely available. Strategies to obtain this information are discussed. Further important aspects are practical considerations when using such reference materials for method evaluation. Statistical procedures can help to obtain the relevant information with a minimum of effort.Presented at BERM-9—Ninth International Symposium on Biological and Environmental Reference Materials, June 15–19, 2003, Berlin, Germany. Views expressed in this paper represent the personal opinion of the author.  相似文献   

8.
In 2007/2008 the Institute for Reference Materials and Measurements (IRMM) organised an interlaboratory comparison (ILC) on the determination of 226Ra, 228Ra, 234U and 238U activity concentrations in mineral water. This paper describes the determination of the reference values for the activity concentrations of 234U and 238U by radiochemical separation and α-particle spectrometry performed at two independent laboratories. The experimental uncertainty of the reference values is discussed in detail.  相似文献   

9.
10.
Voltammetric methods are very suitable and versatile techniques for the simultaneous metal determination in complex matrices after thorough mineralization. In the presented work, voltammetric methods were used as reference methods in the preparation process of control plant material. Determination of As, Pt, Tl and other elements (Cd, Cu, Pb, Zn) in plant material prepared in our laboratory is described. For quantitative determination of the elements two independent analytical methods were applied. To obtain plant material containing As, Pt and Tl white mustard (Sinapis alba L.) was hydroponically cultivated under controlled conditions in a nutrient solution with addition of As, Pt and Tl salts.  相似文献   

11.
12.
The effect of matrix contents on the detection limit of total reflection X-ray fluorescence analysis was experimentally investigated using a set of multielement standard solutions (500 ng/mL of each element) in variable concentrations of NH4NO3. It was found that high matrix concentration, i.e. 0.1–10% NH4NO3, had a strong effect on the detection limits for all investigated elements, whereas no effect was observed at lower matrix concentration, i.e. 0–0.1% NH4NO3.  相似文献   

13.
胶原及明胶基天然高分子复合材料研究进展   总被引:4,自引:0,他引:4  
胶原及其降解物—明胶是自然界中存在的一类丰富的绿色资源,来源广泛,具有可再生、可降解的"绿色"特性。将它们与其它物质复合形成新的复合材料,有着良好的性能和新的特性从而使其具有广阔的应用前景。日益严峻的环境问题,石油资源濒临匮乏,废旧材料的回收等问题使得人们更加寻求新的绿色的环境友好材料。本文根据天然资源各自的结构和性质,从复合方法和机理出发,综述了胶原及明胶与其它天然高分子(壳聚糖、淀粉、丝素蛋白、海藻酸钠)进行共混和复合以制备新的生物复合材料方面的研究进展。  相似文献   

14.
A new selenized yeast reference material (SELM-1) produced by the Institute for National Measurement Standards, National Research Council of Canada (INMS, NRC) certified for total selenium (2,059±64 mg kg−1), methionine (Met, 5,758±277 mg kg−1) and selenomethionine (SeMet, 3,431±157 mg kg−1) content is described. The ±value represents an expanded uncertainty with a coverage factor of 2. SeMet and Met amount contents were established following a methanesulfonic acid digestion of the yeast using GC-MS and LC-MS quantitation. Isotope dilution (ID) calibration was used for both compounds, using 13C-labelled SeMet and Met. Total Se was determined after complete microwave acid digestion based on ID ICP-MS using a 82Se spike or ICP-OES spectrometry using external calibration. An international intercomparison exercise was piloted by NRC to assess the state-of-the-art of measurement of selenomethione in SELM-1. Determination of total Se and methionine was also attempted. Seven laboratories submitted results (2 National Metrology Institutes (NMIs) and 5 university/government laboratories). For SeMet, ten independent mean values were generated. Various acid digestion and enzymatic procedures followed by LC ICP-MS, LC AFS or GC-MS quantitation were used. Four values were based on species-specific ID calibration, one on non-species-specific ID with the remainder using standard addition (SA) or external calibration (EC). For total selenium, laboratories employed various acid digestion procedures followed by ICP-MS, AFS or GC-MS quantitation. Four laboratories employed ID calibration, the remaining used SA or EC. A total of seven independent results were submitted. Results for methionine were reported by only three laboratories, all of which used various acid digestion protocols combined with determination by GC-MS and LC UV. The majority of participants submitted values within the certified range for SeMet and total Se, whereas the intercomparison was judged unsuccessful for Met because only two external laboratories provided values, both of which were outside the certified range.  相似文献   

15.
分析了居民饮用水及其天然水源中微量铀,钍的含量,并与尿液中铀,钍含量进行了比较。结果表明,上海地区天然水源在国家规定的允许范围内,接近于尿液中铀,钍的日排出量。  相似文献   

16.
Herein, we discuss the analyses and quantification of the different components in porphyrin mixtures, prepared from p-anisaldehyde, p-tolualdehyde, and 5-(4-bromophenyl)-dipyrromethane with acid catalysis, using NMR and HPLC. The advantages and disadvantages of these analytical methods are emphasized. Due to the similar size of a bromine atom and a methyl group it was possible to grow crystals suitable for X-ray crystallographic studies from a mixture of porphyrins, where the 4-position of the meso-phenyl rings was either substituted with methyl groups or bromine atoms. We also show that X-ray studies are inferior to NMR analysis for determining the components in a porphyrin mixture.  相似文献   

17.
New reference materials consisting of cobalt thin films on gold were prepared by sputter deposition. The thickness and homogeneity of the films were characterized using synchrotron radiation micro-XRF. The samples can be used as reference materials to quantify cobalt phthalocyanine and cobalt porphyrin modified gold electrodes which have been analyzed with synchrotron radiation micro-XRF.  相似文献   

18.
 Many certified reference materials are needed to calibrate and control analytical measurement processes in integrated steel works. It is beyond the scope and capacity of most national laboratories to supply all of these needs. Yet, the demand for these materials is steadily increasing as more steel producers update their quality systems in preparation for ISO 9000 registration and/or ISO Guide 25 laboratory accreditation assessments. This paper describes how the Bethlehem Steel Corporation updated its reference materials program to meet its internal needs and offers a model for use by others in improving their programs. Received: 22 April 1998 · Accepted: 12 May 1998  相似文献   

19.
A simple, fast, robust and reliable multicomponent analytical method applicable in control laboratories with a high throughput level has been developed to analyze commercial brands of perfumes. Contents of 52 cosmetic ingredients belonging to different chemical families can be determined in a single run. Instrumental linearity, precision of the method and recovery studies in real samples showed excellent results, so that quantification by external calibration can be effectively applied. Relevant limits of detection and quantification were obtained for all the targets considered, far below the legal requirements and amply adequate for its accurate analytical control.A survey of 70 commercial perfumes and colognes has been performed, in order to verify whether these products complied with the recent changes in European legislation: regarding the maxima allowed concentrations of the ingredients and/or ingredient labelling. All samples contained some of the target ingredients. Several samples do not comply with the regulations concerning the presence of phthalates. Musks data confirmed the trend about the replacement of nitromusks by polycyclic musks; as well as the noticeable introduction of macrocyclic musks in the perfumes composition. The prohibited musk moskene has been detected in one sample in an appreciable concentration. The average number of fragrance allergens is twelve per sample; their presence must be indicated in the list of ingredients when its concentration exceeds the 0.001%, but values higher than 1% have been found in some samples. Preservatives data show that parabens, although ubiquitous in other cosmetic products, are not widely used in perfumery. In contrast, the presence of BHT is indeed widespread. The degree of compliance with the European Regulation on the labelling has been evaluated in a subset of samples, and only about the 38% of the perfumes were properly labelled for the allergens tested.  相似文献   

20.
The Me.Tos. Project, started in 1983 and still running, is an external quality assessment (EQA) scheme for laboratories performing specialized analyses in occupational and environmental laboratory medicine. Besides the organization of EQA exercises, initiatives for further education of the participants and the harmonization of EQA procedures at a European level are carried out. Participation in EQA schemes allows laboratories to comply with the international standards for the quality and competence of testing and clinical laboratories. The organization of the scheme includes the preparation of control materials, their distribution to the participants, according to strategies aimed to avoid identification of the samples, the statistical analysis of the results and the evaluation of laboratories' performance according to international guidelines and criteria set by the organizers. An overview of the scheme operation and the current performances of participants will be given.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号