首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 93 毫秒
1.
Metal-organic frameworks (MOFs) have received great attention as novel sorbents due to their fascinating structures and intriguing potential applications in various fields. In this work, a MIL-101(Cr)-coated solid-phase microextraction (SPME) fiber was fabricated by a simple direct coating method and applied to the determination of volatile compounds (BTEX, benzene, toluene, ethylbenzene, m-xylene and o-xylene) and semi-volatile compounds (PAHs, polycyclic aromatic hydrocarbons) from water samples. The extraction and desorption conditions of headspace SPME (HS-SPME) were optimized. Under the optimized conditions, the established methods exhibited excellent extraction performance. Good precision (<7.7%) and low detection limits (0.32–1.7 ng L−1 and 0.12–2.1 ng L−1 for BTEX and PAHs, respectively) were achieved. In addition, the MIL-101(Cr)-coated fiber possessed good thermal stability, and the fiber can be reused over 150 times. The fiber was successfully applied to the analysis of BTEX and PAHs in river water by coupling with gas chromatography–mass spectrometry (GC–MS). The analytes at low concentrations (1.7 and 10 ng L−1) were detected, and the recoveries obtained with the spiked river water samples were in the range of 80.0–113% and 84.8–106% for BTEX and PAHs, respectively, which demonstrated the applicability of the self-made fiber.  相似文献   

2.
Encapsulation and controlled release of volatile molecules such as fragrances in a designed manner is important but challenging for the flavor and fragrance industry. Here, we report the tuning release of volatile molecules by postsynthetic modification of an amine-terminated metal-organic framework(MOF) MIL-101-NH_2. By amidation, we obtained three MIL-101 MOFs, the trimethylacetamideterminated TC-MIL-101, the benzamide-terminated BC-MIL-101, and the oxalic acid monoamideterminated OC-MIL-101. All the MOFs can efficiently encapsulate volatile molecules. Moreover, we demonstrate that the release profile of volatiles can be widely tuned to sustain the release in several days to months and even over a year using different modified MIL-101 MOFs. We show that the release profiles are correlated with the binding energies between the guest volatiles and pores in MOFs. The pore diffusion and the synergistic transport are the rate-limiting step of the guest molecules from the modified MOFs.  相似文献   

3.
Long Y  Chen Y  Yang F  Chen C  Pan D  Cai Q  Yao S 《The Analyst》2012,137(11):2716-2722
Triphenylamine (TPA)-functionalized magnetic microspheres (Fe(3)O(4)/SiO(2)/TPA) were prepared and applied as solid phase extraction (SPE) adsorbents for the analysis of polycyclic aromatic hydrocarbons (PAHs) in environmental samples in combination with high-performance liquid chromatography (HPLC). The magnetic solid-phase extraction (MSPE) conditions affecting the extraction efficiency were optimized, including elution solvent, standing time, amount of sorbent, and salt concentration. Due to the strong π-π conjugate effect between the benzene rings of TPA and PAHs, high extraction efficiency was achieved with spiked recoveries of 80.21-108.33% and relative standard deviations (RSD) of less than 10%. Good linearities (R(2) > 0.997) for all calibration curves were obtained with low limits of detection (LOD) of 0.25, 0.5, 0.5, 3.75, 0.2 and 0.04 ng L(-1) for anthracene, fluoranthene, pyrene, chrysene, benzo[b]fluoranthene and benzo[k]fluoranthene, respectively. The achieved results indicate the applicability of Fe(3)O(4)/SiO(2)/TPA as MSPE adsorbents.  相似文献   

4.
Jin J  Zhang Z  Li Y  Lu X  Wu L  Chen J 《Analytica chimica acta》2011,693(1-2):54-61
A new solid-phase extraction sorbent, octadecyl modified magnesium oxide (C18-MgO) microspheres, was successfully prepared in the present work. Its composition, morphology and structure were studied by Fourier transform infrared spectroscopy (FTIR), scanning electron microscopy (SEM), N(2) adsorption-desorption technique, and solid-state nuclear magnetic resonance (NMR). The as-synthesized C18-MgO was employed as a solid-phase extraction sorbent for the enrichment of polycyclic aromatic hydrocarbons (PAHs) in aqueous solutions. Several factors affecting the extraction efficiency of PAHs, including the type and concentration of organic modifiers, flow rate, sample volume, and the types of rinsing solvents and eluting solvents, were investigated systematically. The results demonstrated that C18-MgO was superior to MgO in terms of large volume in loading samples. In comparison with MgO and Sep-Pak C18, C18-MgO exhibited excellent extraction efficiency (>91% except for naphthalene) in respect of high recoveries under the optimized conditions. The limits of detection varied from 0.001 to 0.603 ng mL(-1) for 15 PAHs using high-performance liquid chromatography coupled with a fluorescence detector, indicating that the analytical method was highly sensitive. The proposed method was applied to enrich PAHs in tap water and acceptable recoveries (18-96%) were obtained.  相似文献   

5.
张文敏  李青青  方敏  张兰 《色谱》2022,40(11):1022-1030
环境样品中多环芳烃(PAHs)含量较低且样品基质复杂,直接利用仪器进行含量测定比较困难,因此在仪器分析之前需要对环境样品进行必要的前处理。大多数前处理技术的萃取效率取决于萃取材料的特性。目前,金属有机骨架材料(MOFs)作为一种由金属离子与有机配体自组装而成的多孔材料,已经被用作固相微萃取(SPME)的涂层材料应用于PAHs的萃取,但是这些MOFs涂层材料由于目标物较难达到其深层的吸附位点,使得萃取过程往往需要较长的平衡时间;此外,大多数MOFs由单金属离子配位构成,能够提供的开放金属活性位点种类比较单一,较难获得最佳的萃取性能。这些问题在一定程度上限制了MOFs材料在SPME领域的应用。该研究制备了一种中空结构的双金属有机骨架材料(H-BiMOF),并将其作为SPME的涂层材料,用于萃取环境样品中痕量的PAHs。由于中空的结构和双金属的组成,H-BiMOF涂层材料拥有比表面积利用率高、传质距离短等优点,可以使萃取过程快速地达到平衡。同时,双金属的引入提供了种类丰富的金属活性位点,提高了对PAHs这类富电子云目标物的萃取效率。与气相色谱-串联质谱(GC-MS/MS)相结合,建立了一种用于环境水样中PAHs分析的新方法。所建立的分析方法具有检出限低(0.01~0.08 ng/L)、线性范围宽(0.03~500.0 ng/L)、重复性良好(相对标准偏差≤9.8%, n=5)等优点,并成功地用于实际湖水样品中7种PAHs的检测。实验结果表明,所建立的分析方法适用于环境样品中PAHs的分析与监测。  相似文献   

6.
Research on Chemical Intermediates - Herein, a novel method entitled magnetic solid-phase extraction based on MIL-101(Cr)/Fe3O4@SiO2@propylthiouracil composite was developed using the magnetite...  相似文献   

7.
Metal-organic frameworks (MOFs) with open metal sites have great potential for enhancing adsorption separation of the molecules with different polarities. However, the elution and separation of polar compounds on such MOFs packed columns using nonpolar solvents is difficult due to too strong interaction between polar compounds and the open metal sites. Here, we report the control of the coordination status of the open metal sites in MOFs by adjusting the content of methanol (MeOH) in the mobile phase for fast and high-resolution separation of polar compounds. To this end, high-performance liquid chromatographic separation of nitroaniline, aminophenol and naphthol isomers, sulfadimidine, and sulfanilamide on the column packed with MIL-101(Cr) possessing open metal sites was performed. The interaction between the open metal sites of MIL-101(Cr) and the polar analytes was adjusted by adding an appropriate amount of MeOH to the mobile phase to achieve the effective separation of the polar analytes due to the competition of MeOH with the analytes for the open metal sites. Fourier transform infrared spectra and X-ray photoelectron spectra confirmed the interaction between MeOH and the open metal sites of MIL-101(Cr). Thermodynamic parameters were measured to evaluate the effect of the content of MeOH in the mobile phase on the separation of polar analytes on MIL-101(Cr) packed column. This approach provides reproducible and high performance separation of polar compounds on the open metal sites-containing MOFs.  相似文献   

8.
Impregnation of ionic nanostructured units in the pores of metal-organic frameworks (MOFs) is one approach to modify their host–guest interactions. Although, the effect of this approach is well investigated in catalysis, drug delivery, and bio imaging, still little is known about its impact on the selective adsorption properties of MOFs. Here we report the impregnation of two different polyoxometalate (POM) nanoclusters (PW11 and SiW11) into chromium terephthalate-based MOF, MIL-101(Cr), to investigate the post-impregnation changes in selective adsorption behavior, which are observed in terms of an important paraffin–olefin separation, using ethane and ethylene, at high pressure. The PW11 and SiW11 POMs bring π-accepting tendency and highly electronegative oxygen atoms on their surface to MIL-101 structure that selectively increases the affinity of material for ethylene, which is confirmed from isosteric heats of adsorption and selectivity calculation. Impregnated samples retain about 74–81 % of working adsorption capacity, after regeneration by decreasing the pressure. This study shows that anionic metal-oxide nanoclusters (POMs) may be used to change the selectivity of MOFs for olefin molecules.  相似文献   

9.
The copper(II) isonicotinate (Cu(4-C5H4N-COO)2(H2O)4) coordination polymer was prepared, characterized and explored as sorbent for flow injection solid-phase extraction on-line coupled with high-performance liquid chromatography (HPLC) for determination of trace polycyclic aromatic hydrocarbons (PAHs) in environmental matrices. Naphthalene, phenanthrene, anthracene, fluoranthene, benzo(b)fluoranthene, benzo(k)fluoranthene, benzo(a)pyrene and benzo(ghi)perylene with various shape, size and hydrophobicity were used as model analytes. The porosity of the coordination polymer allows these guest PAHs molecules to diffuse into the buck structure, and the shape and size of the pores lead to shape- and size-selectivity over the guests. The precolumn packed with the coordination polymer was shown to be promising for solid-phase extraction of PAHs in environmental samples with subsequent HPLC separation and UV detection. With extraction of 50 ml of sample solution, the enhancement factors for the PAHs studied ranged from 200 to 2337, depending on the shape, size and hydrophobic property of the PAHs. The detection limits (S/N = 3) of 2-14 ng l(-1) and the sample throughput of 3 samples h(-1) were obtained. The developed method was applied to the determination of trace PAHs in a certified reference material (coal fly ash) and local water samples.  相似文献   

10.
Porous nanosized metal–organic frameworks (MOFs) are becoming possible candidates as drug-delivery nanocarriers for their versatile porous structures and large loadings of drugs. However, controlling synthesis of MOFs with uniform morphology, good biocompatibility and targeting drug delivery is still a challenge, which greatly limits their clinical applications. Herein, a multifunctional nano-sized drug-delivery material MIL-101(Fe)@FU@FA with a uniform particle size about 500 nm was successfully synthesized for targeting therapeutic purposes. The targeting reagent folic acid (FA) molecules are connected on the surface of 5-FU-loaded nanoparticle MIL-101(Fe)-NH2 by a covalent conjugation. Cytotoxicity tests showed that the synthesized nanoparticles are biocompatible and can significantly inhibit cell proliferation on SMMC-7721 cells compared with MIL-101(Fe)@FU and free 5-FU. The cell metastasis and invasion experiments proved that the nanoparticles had a good anti-metastasis ability to tumor cells. Mechanistically, MIL-101(Fe)@FU@FA induces apoptosis of SMMC-7721 cells and block cell cycle progression in the G2/M phase. Taken together, the drug-loaded nanoparticles MIL-101(Fe)@FU@FA have the effect of targeting and sustained release to achieve the therapeutic effect.  相似文献   

11.
A method for the determination of 27 polycyclic aromatic hydrocarbons (PAHs) in sludge from wastewater treatment plants (WWTPs) located in urban, industrial or rural zones is presented. PAHs were extracted by matrix solid-phase dispersion (MSPD) assisted by sonication. Purification of extracts was carried out by solid-phase extraction with C(18) and PAHs were eluted with acetonitrile. PAHs were determined by isotope dilution gas chromatography with electron impact mass spectrometric detection in the selected ion-monitoring mode (GC-MS-SIM), using deuterated PAHs as internal standards. The limits of detection ranged from 0.03 ng/g for acenaphthylene to 0.45 ng/g for benzo[b]naphtho[2,1-d]thyophene. After optimization, the method was validated with a certified reference sludge. The proposed analytical method was applied to determine PAH levels in sewage sludge samples collected from 19 water treatment plants located in the province of Madrid (Spain). In most of the examined samples, phenanthrene was the main compound with a mean concentration of 1062 ng/g. PAHs were detected in all of the samples, with total concentrations between 390 and 6390 ng/g dry weight for the 27 PAHs analyzed and from 310 to 5120 ng/g dry weight for the sum of the 10 PAHs considered in the draft European Union directive.  相似文献   

12.
建立了磁性聚亚苯基共轭微孔聚合物富集/表面增强拉曼光谱法测定水样和土壤中4种多环芳烃的分析方法。待测物经磁性聚亚苯基共轭微孔聚合物吸附萃取,甲醇洗脱后进行SERS检测。结果表明,蒽、芘、荧蒽和苯[α]芘在0.1~10μg/L范围内与其SERS特征峰峰强呈良好的线性关系,检出限为0.03μg/L,回收率为71.6%~115.8%,相对标准偏差不大于13.7%。该分析方法灵敏度高,能够满足实际水样和土壤中4种多环芳烃同时检测的要求。  相似文献   

13.
C18-functionalized magnetic microspheres synthesized in a three-stage system and characterized by Fourier transform infrared (FTIR) spectroscopy and SEM were applied for clean-up and enrichment of polycyclic aromatic hydrocarbons (PAHs) in soil samples combined with ultrasonication extraction. Magnetic solid-phase extraction (MSPE) parameters, such as elution solvents, amounts of sorbents, enrichment time and organic modifier, were optimized together with ultrasonication time and extraction solvents. Under the optimal conditions, the developed method provided spiked recoveries of 63.2-92.8% with RSDs of less than 6.4% and limits of detection were 0.5-1.0 ng/g. This new method provides several advantages, such as high extraction efficiency, convenient extraction procedure and short analysis times. Finally, the method was successfully applied to the determination of polycyclic aromatic hydrocarbons in soil samples.  相似文献   

14.
Multiwalled carbon nanotubes (MWCNTs) were used as a novel kind of solid-phase extraction adsorbents in this work as well as an analytical method based on MWCNTs solid-phase extraction (SPE) combined with high-performance liquid chromatography (HPLC) was established for the determination of polycyclic aromatic hydrocarbons (PAHs), some of which belong to typical persistent organic pollutants (POPs) owing to their carcinogenicity and endocrine disrupting activity. Several conditions that probably affected the extraction efficiency including the eluent volume, sample flow rate, sample pH and the sample volume were optimized in detail. The characteristic data of analytical performance were determined to investigate the sensitivity and precision of the method, and the method was applied to the determination of PAHs in environmental water samples such as river water sample, tap water sample and wastewater sample from the constructed wetland effluent. The experimental results indicated that there were excellent linear relationship between peak area and the concentration of PAHs over the range of 0.04-100 microg L(-1), and the precisions (RSD) were 1.7-4.8% under the optimal conditions. The detection limits of proposed method for the studied PAHs were 0.005-0.058 microg L(-1) (S/N=3). The recoveries of PAHs spiked in environmental water samples ranged from 78.7 to 118.1%. It was concluded that MWCNTs packed cartridge coupled with HPLC was an excellent alternative for the routine analysis of PAHs at trace level.  相似文献   

15.
In this work, magnetic multiwalled carbon nanotubes were synthesized through a facile hydrothermal process, and then successfully used as magnetic solid-phase extraction sorbents for the determination of p-hydroxybenzoates in beverage. The prepared magnetic multiwalled carbon nanotubes presented both satisfactory superparamagnetism and strong capacity of absorption, with magnetic Fe(3)O(4) beads of 200 nm average diameters decorated at either ends of the tubes. The hybrid nanocomposites showed a high efficiency in the extraction and enrichment of p-hydroxybenzoates via π-π stacking of targeted molecules onto the polyaromatic composed surface of multiwalled carbon nanotubes, which entitled them promising magnetic solid-phase extraction sorbents for p-hydroxybenzoates at trace level from complex drink samples. By using an external magnetic field, p-hydroxybenzoates adsorbed on magnetic multiwalled carbon nanotubes could be rapidly isolated in only 30 s, and subsequently analyzed by liquid chromatography-diode array detector after elution with organic solvents. Extraction conditions such as eluting solvent, the amounts of magnetic sorbents added, pH values, adsorption and desorption time were investigated and optimized to achieve the best effect. Method validations including linearity, detection limit, and precision were also studied. The linearities were in the wide range of 0.05-500 μg/mL with correlation coefficients higher than 0.9983 for all p-hydroxybenzoates. The limits of detection were less than 20 ng/mL. Acceptable RSDs were achieved within 5-8% for all analytes. The results indicated that the proposed method based on magnetic multiwalled carbon nanotubes as magnetic solid-phase extraction absorbents was rapid, efficient, and convenient for the analysis of the targeted compounds of p-hydroxybenzoates in beverage sample.  相似文献   

16.
Mesoporous MOFs MIL-100 and MIL-101 adsorb huge amounts of CO2 and CH4. Characterization was performed using both manometry and gravimetry in different laboratories for isotherms coupled with microcalorimetry and FTIR to specify the gas-solid interactions. In particular, the uptake of carbon dioxide in MIL-101 has been shown to occur with a record capacity of 40 mmol g(-1) or 390 cm3STP cm(-3) at 5 MPa and 303 K.  相似文献   

17.
β-Blockers and β2-agonists are commonly prescribed for therapeutic treatments and are also administered to livestock, leading to their presence in both environmental and biological samples. Hence, the development of sensitive, rapid, and reliable analytical methods for the determination of β-blockers and β2-agonists in environmental and biological samples is important. In this study, MIL-101(Cr)-NH2&GO-coated SiO2/Fe3O4 magnetic particles were prepared as sorbents for magnetic solid-phase extraction and then combined with high-performance liquid chromatography-tandem mass spectrometry for the analysis of 20 β-blockers and eight β2-agonists. The experimental parameters of magnetic solid-phase extraction were studied in detail, and the optimal conditions were established. Under optimal conditions, the limits of detection were in the range of 0.002–0.007 μg/L with enrichment factors of 20.2–24.9. The developed method was successfully applied for the determination of 20 β-blockers and eight β2-agonists in river water, human urine, and freeze-dried pork liver powder. Bisoprolol and salbutamol were detected at concentrations of 2.78 mg/L in human urine and 11.5 μg/kg in freeze-dried pork liver powder.  相似文献   

18.
A multiresidue method was developed for the de termination of 16 polycyclic aromatic hydrocarbons (PAHs) in unifloral and multifloral honeys. The analytical procedure is based on the matrix solid-phase dispersion of honey on a mixture of Florisil and anhydrous sodium sulfate in small glass columns and extraction with hexane-ethyl acetate (90 + 10, v/v) with assisted sonication. The PAH residues are determined by gas chromatography with mass spectrometric detection using selected-ion monitoring. Average recoveries for all the PAHs studied were in the range of almost 80 to 101%, with relative standard deviations of 6 to 15%. The limits of detection ranged from 0.04 to 2.9 microg/kg. The simultaneous extraction and cleanup of samples makes this method simple and rapid, with low consumption of organic solvents  相似文献   

19.
A new method for the determination of polycyclic aromatic hydrocarbons (PAHs) in waste water using solvent-free solid-phase microextraction (SPME) is described. The PAHs are extracted with a 100 microm polydimethylsiloxane (PDMS) fiber, desorbed in 40 microl acetonitrile and measured with LC and fluorescence detection. The detection limits of this very simple method under the given conditions (extraction from 5 ml sample, extraction time 1 h) are in the range of 1-6 ng l(-1). The standard deviations (n = 6) at a concentration level of 0.8 microg l(-1) are between 1.8 and 14.4%. The procedure was used for the determination of PAHs in contaminated water samples.  相似文献   

20.
Using cotton as a solid-phase extraction sorbent of the precolumn, an on-line coupled precolumn preconcentration-liquid chromatography system with fluorescence detection was developed for the determination of PAHs in aqueous samples. Four PAHs including fluorene, phenanthrene, fluoranthene and benzo[k]fluoranthene were preconcentrated by a precolumn packed with 30 mg of absorbent cotton and then separated by C18 analytical column. When 100 ml of sample was enriched, the proposed procedure provided detection limits in the range of 0.5-57 ng l−1. Several water samples spiked with PAHs were analyzed with recoveries in the range of 92-119% at spiking level of 100 ng l−1 for fluorene, phenanthrene and fluoranthene, and 10 ng l−1 for benzo[k]fluoranthene, respectively.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号