首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 955 毫秒
1.
A major problem in the determination of polycyclic aromatic compounds (PACs) in environmental samples is the extreme complexity of the extracts, even after extensive fractionation. The combination of high-performance liquid chromatography (HPLC) with simultaneous mass spectrometry (MS) and ultraviolet diode array detection (DAD) is a powerful tool for the identification and quantitation of such species with a high degree of confidence. HPLC allows the selective separation of a wide variety of PACs, including thermally labile and high molecular weight compounds. Electron ionization MS with the moving belt interface provides high sensitivity and selectivity, as well as structural information such as molecular weight, functional groups, and elemental composition. The diode array detector helps to differentiate isomeric structures and confirm compound identity.  相似文献   

2.
The aim of this work was to optimise and validate the experimental conditions for the analysis of 20 polycyclic aromatic compounds (PACs) [19 polycyclic aromatic hydrocarbons (PAHs) and dibenzothiophene as polycyclic aromatic sulphur heterocycle (PASH)] in marine sediments by reversed-phase high-performance liquid chromatography (LC) coupled to photodiode array detection (DAD) and to mass spectrometry (MS). The LC-MS interface used was atmospheric pressure chemical ionization (APCI) in the positive ion mode. The operational parameters of the APCI interface and MS detection, such as organic modifier, fragmentation voltage, gain, vaporizer temperature, corona current, capillary voltage, drying gas (N2) and nebulizer pressure, were studied. The sediments were subjected to microwave-assisted solvent extraction (MAE) and clean-up by solid-phase extraction (SPE). The relevance of the selected PACs lies in the fact that 16 PACs are classified by the US Environmental Protection Agency as priority pollutants; 17 PACs are detected in the Prestige oil spill; and 8 PACs are included in the priority substance list of the EU water policy. Recoveries from 47% to 102% were obtained for SRM 1944 certified reference sediment. The limits of quantitation were lower than 100 ngg(-1) dry weight for most PACs, and good precision was achieved.  相似文献   

3.
Reconstructed ion chromatograms have been used to identify relevant high performance liquid chromatography (HPLC) peaks in a directly coupled high performance liquid chromatography/nuclear magnetic resonance spectroscopy/mass spectrometry (HPLC/NMR/MS) experiment. This has been applied to a study of the metabolism of a model compound, 5-nitropyridone (2-hydroxy-5-nitropyridine), in maize plants grown hydroponically. By monitoring the on-flow reconstructed ion chromatogram corresponding to the 5-nitropyridone fragment at m/z 143, and additional molecular ions corresponding to metabolites identified as products from similar compounds, relevant peaks were identified rapidly for subsequent stopped-flow 1H NMR spectroscopic analysis. The combination of coupled HPLC/NMR/MS enabled the direct identification of three metabolites, namely the N-glucoside, N-malonylglucoside, and O-malonylglucoside. This work demonstrates the power of HPLC/NMR/MS for the structural elucidation of xenobiotic metabolites in complex biological matrices (such as plant material) with minimal sample preparation. In particular, using mass spectrometry for the initial identification of relevant HPLC peaks allows the analysis of complex samples without the necessity for other spectroscopic markers, such as 19F NMR signal for fluorinated compounds or UV spectroscopy for molecules with strong UV chromophores.  相似文献   

4.
This work reports on some methodological aspects of an off‐line combination of preparative ITP and HPLC with mass spectrometric detection (pITP‐HPLC‐MS) and its potential applications to the analysis of high molecular mass compounds present in complex biological matrices from the analytical chemistry perspective. Lysozyme served as the model analyte and human saliva as the complex biological matrix in this study. A mixture of five low‐molecular mass compounds was found and successfully used in the pITP experiments as discrete spacers to isolate the analyte from the interferents present in the complex biological matrix and to minimize their disturbance effect on the final MS analysis. The experiments at the pITP stage were performed in the cationic mode. On‐column conductivity detectors were used for the detection of ITP zones. Lysozyme was found in the human saliva samples using just deconvolution of the MS data after background correction. The MS data obtained from HPLC‐MS analysis of pITP fractions exhibited the great analytical potential of the combination of pITP‐HPLC‐MS resulting from the ITP clean‐up effect as well as the ITP preconcentration of the analyte present at low concentration levels in complex biological matrices.  相似文献   

5.
Two standard solutions of deuterated polycyclic aromatic compounds (PACs) have been prepared for use as surrogate internal standards. Solution DPAC-1 contains 21 deuterated PACs, and is intended for use with mass spectrometric (MS) detection. Most of the difficulties in certifying concentrations in DPAC-1 arose from the fact that none of the individual compounds was 100% deuterated, so that effects of mass spectrometric fragmentation are convoluted with those of isotopic distributions. The best methods are discussed for using such internal standards so as to minimize these problems, together with those arising from kinetic isotope effects. Solution DPAC-2 contains 6 deuterated PACs, and is primarily intended for use with reversed-phase high-performance liquid chromatography (HPLC) with fluorescence detection (FLD, dual programmed wavelength mode), in which the signals for analyte and internal standard are separated chromatographically rather than via the detector. Full details of the preparation of these solutions are described. In addition, examples of their use in the analysis of a certified coal-tar extract (NIST SRM 1597) are described briefly. In one example a novel HPLC-MS technique was employed, and in the other the HPLC-FLD technique was used.NRCC No. 38030  相似文献   

6.
Studying the permeability of compounds across a Caco-2 cell monolayer is an established in vitro model to screen for oral absorption and to evaluate the mechanism of transport. This assay can also be used to evaluate compounds as potential P-glycoprotein substrates and/or inhibitors. The traditional methods of sample analysis (high-performance liquid chromatography (HPLC) with a UV or fluorescence detector) limit the throughput and sensitivity of this assay. Data are presented here describing the use of liquid chromatography/tandem mass spectrometry (LC/MS/MS) for the analysis of samples derived from the Caco-2 cell studies. During the analysis an automatic switching valve was used to divert the flow from the HPLC column to waste for the first minute, preventing the early eluting salts from entering and contaminating the LC/MS interface. This approach allows the rapid and accurate determination of drug transport across the Caco-2 cell monolayer. The high sensitivity and specificity of LC/MS/MS make this technique an ideal candidate for the low concentration and high throughput routine analysis of Caco-2 cell solutions, especially if multiple compounds are administered and analyzed simultaneously. Thus, the use of LC/MS/MS will increase the value of the Caco-2 cell assay as an in vitro screening tool.  相似文献   

7.
天麻中对羟基苯类化合物的(EsI(-))一级质谱图中除分子离子峰[M-1]外,还可见明显的[M-1 20] m[2m-1]峰,由此规律可方便确证未知同类样品的分子离子峰。由二级质谱(ESI/MS/MS)的特征碎片离子93、105和107等,结合紫外光谱及核磁结果确定了3个不纯样品中主要成分的结构,同时初步确定了两个同类杂质的结构。  相似文献   

8.
Fresh grapes and grape products, such as grape wine and grape juice, were analyzed for proanthocyanidins (PACs) using liquid chromatography with electrospray ionization mass spectrometric (MS) detection. PACs were successfully separated and analyzed on the basis of their protonated molecules, allowing the identification of PACs in different degrees of polymerization from monomers to oligomers (up to 7 units), and in various isomeric forms. Using reversed-phase high-performance liquid chromatography (HPLC) combined with MS detection, the PAC monomers, (+)-catechin (C), (-)-epicatechin (EC), (-)-catechin gallate (CG), and (-)-epicatechin gallate (ECG), were successfully quantified using selected ion monitoring (SIM) mode. Standard curves were fitted for each PAC ranging from 43.8 to 5600 ng/mL for C, from 42.2 to 5400 ng/mL for EC, from 36.7 to 4700 ng/mL for CG, and from 39.8 to 5100 ng/mL for ECG. Good linearity (r2>0.999) was achieved for each analyte. The accuracy and precision (RSD) were within 10% (n=8) at the limit of detection. This method allows direct quantification of monomeric PACs in fresh grapes and grape-derived products. Additionally, flow injection analysis (FIA) was applied to estimate the concentration levels of PAC oligomers by comparing their FIA-MS peak areas, which were well correlated (r2=0.936) to the total concentrations of PAC monomers.  相似文献   

9.
An automated packed-column semi-preparative supercritical fluid chromatography/mass spectrometry (SFC/MS) system incorporating mass-directed fraction collection has been designed and implemented as an alternative to preparative HPLC and preparative HPLC/MS (PrepLC/MS) for the purification of pharmaceutical compounds. The system incorporates a single quadrupole mass spectrometer and a supercritical fluid chromatograph. Separations were achieved using a binary solvent system consisting of carbon dioxide and methanol. Purification of SFC-separated compounds was achieved incorporating mass-directed fraction collection, enabling selective isolation of the target molecular weight compound and eliminating the collection of undesired compounds (e.g., by-products, excess starting materials, etc.). Cross contamination between fractions and recoveries of the system were investigated. Mass spectrometer ionization with basic mobile additives is discussed, and examples of preparative SFC/MS chiral separations are presented. Early experiences suggest SFC will be a powerful and complementary technique to HPLC for the purification of pharmaceutical compounds.  相似文献   

10.
11.
Medemia argun is an ancient palm rich in proanthocyanidins (PACs). These polyphenolic compounds are widely distributed in plants and are an integral part of the human diet. A sensitive high‐performance liquid chromatography and electrospray ionization mass spectrometry (HPLC–ESI–MS) method in the negative ion mode for sequencing these ubiquitous and highly beneficial antioxidants is described in order to profile different PACs in M. argun nuts. The analytical protocol based on tandem mass spectrometry was used to sequence dimers, trimers, tetramers and pentamers with different A‐type, B‐type and A/B‐type linkages. Diagnostic ions resulting from heterocyclic ring fission and retro‐Diels–Alder reaction of flavan‐3‐ol provided information on the hydroxylation pattern and the type of interflavan bond. The sequences were discovered through ions derived from quinone methide cleavage of the interflavan bond. The identification of PACs linkages through LC–MSn eliminates a number of tedious separation steps. The method was successfully applied to give a view of PAC profile in M. argun nuts. M. argun nuts contained 636.88 mg/g PACs (as equivalent of (þ)‐catechin). The data obtained in our research show that M. argun is a rich source of hydrolyzable PACs. Copyright © 2014 John Wiley & Sons, Ltd.  相似文献   

12.
The continuous development in analytical instrumentation has brought the newly developed Orbitrap‐based gas chromatography / mass spectrometry (GC/MS) instrument into the forefront for the analysis of complex mixtures such as crude oil. Traditional instrumentation usually requires a choice to be made between mass resolving power or an efficient chromatographic separation, which ideally enables the distinction of structural isomers that is not possible by mass spectrometry alone. Now, these features can be combined, thus enabling a deeper understanding of the constituents of volatile samples on a molecular level. Although electron ionization is the most popular ionization method employed in GC/MS analysis, the need for softer ionization methods has led to the utilization of atmospheric pressure ionization sources. The last arrival to this family is the atmospheric pressure photoionization (APPI), which was originally developed for liquid chromatography / mass spectrometry (LC/MS). With a newly developed commercial GC‐APPI interface, it is possible to extend the characterization of unknown compounds. Here, first results about the capabilities of the GC/MS instrument under high or low energy EI or APPI are reported on a volatile gas condensate. The use of different ionization energies helps matching the low abundant molecular ions to the structurally important fragment ions. A broad range of compounds from polar to medium polar were successfully detected and complementary information regarding the analyte was obtained.  相似文献   

13.
Comprehensive two-dimensional gas chromatography coupled to time-of-flight mass spectrometry (GC×GC/ToF-MS) was used for the analysis of thia-arenes and aza-arenes in standard mixtures containing 45 polycyclic aromatic compounds (PACs), and in the aromatic fraction of snowpack samples collected from the Athabasca oil sands area of Alberta, Canada. The GC columns used included a shape-selective liquid-crystalline stationary phase (LC-50) and a high-polarity ionic-liquid stationary phase (SLB-IL60), both in the first dimension. A fast diffusion and low-polarity nano-stationary phase (NSP-35) and a mid-polarity stationary phase (Rxi-17), were used in the second dimension, respectively. Both configurations showed good repeatability for retention times in the first and second dimensions, peak areas and peak heights. Instrument detection limits ranged from 0.5 to 10 pg µL?1 for both configurations. In general, the LC-50×NSP-35 configuration favoured the separation of isomeric compounds by using more of the 2D chromatographic space available (>80%), particularly for compounds with molecular mass >160 u. Therefore, LC-50×NSP-35 was recommended for the analysis of thia-arenes and alkylated PAHs in environmental samples collected from the oil sands area. Alternatively, the SLB-IL60×Rxi-17 configuration favoured molecular similarity grouping over isomer separation. This was observed for a group of aza-arenes (i.e. carbazoles, benzo[a]carbazoles and alkylated-derivatives), which were resolved from other PACs and from the sample matrix. The risk of false positives and overestimations in the analysis of thia-arenes, aza-arenes and alkylated PACs in one-dimension GC/MS was explored and further reduced by using GC×GC/ToF-MS with LC-50×NSP-35 and SLB-IL60×Rxi-17.  相似文献   

14.
The development of a method for selective detection of nitrated polycyclic aromatic hydrocarbons (nitro-PAHs) among other polycyclic aromatic compounds (PACs) is described. The method is based on electrospray ionization mass spectrometry (ESI-MS), performed with a triple quadrupole analyzer and constant neutral loss (CNL) scanning. When subjected to ESI conditions, nitro-PAHs give rise to M(-), [M - H](-) and [M - H + 16](-) ions, which in turn produce fragments by losing 30 u, most probably NO. Other PACs do not undergo such fragmentations, and these differences can be exploited for selective detection of nitro-PAHs among other PACs. Nitro-PAHs can therefore be monitored through the loss of 30 u occurring under negative ion mode ESI conditions. Toward the full development of a screening method for nitro-PAHs, this article first discusses some general aspects of the negative ion mode full-scan ESI mass spectra obtained for these compounds and other PAH derivatives. Because the extent of observation of the loss of 30 u is sensitive to the ESI conditions used, the effects of ionization parameters such as solvent used, declustering voltage, and solvent flow rate are evaluated and discussed. Setting these parameters is very important, especially when interfacing a high performance liquid chromatography (HPLC) system with the ESI source of a triple quadrupole mass spectrometer. Preliminary results of on-line microbore HPLC/ESI-MS separations of PAC standards are presented, and elution/ionization conditions discussed.  相似文献   

15.
The high-molecular-weight polynuclear aromatic hydrocarbon (PAC) fraction of a carbon black extract was isolated with a backflush technique, and applied to an amino-bonded stationary phase for HPLC. This fraction was further separated into 44 sub-fractions by means of reversed-phase HPLC, on an ODS column. Low-temperature fluorescence, utilizing the Shpol'skii effect, was then applied to each fraction. By this method, quasilinear spectra were recorded from mostly peri- condensed PACs with molecular weights up to 400 daltons. Nine compounds with molecular weights exceeding 300 daltons were identified.  相似文献   

16.
High performance liquid chromatography/mass spectrometry (HPLC/MS) has become a widely used technique for routine analysis of pharmaceutical compounds. The constant search for new drugs requires the development of time-efficient methods that can be employed in high-throughput screening of combinatorial libraries of a variety of compounds, including amines and peptides. Conventional HPLC/MS is a powerful technique that can easily be automated and is suitable for comprehensive screening purposes. However, the unequivocal determination of the presence and location of important carbamoyl protecting groups of amines is often elusive because of their inherent instability under MS conditions. In this study, the use of on-column H/D exchange HPLC/ESI/MS for structure elucidation of t-Boc protecting groups which can often not be detected by MS because of facile McLafferty rearrangement has been examined. We demonstrate that employing a deuterated mobile phase in HPLC/MS analysis provides a convenient tool for the determination of the absence or presence of t-Boc protecting groups in amines and peptides.  相似文献   

17.
吉宏武  丁霄霖  陶冠军 《色谱》2001,19(5):403-406
 利用高效液相色谱 电喷雾电离质谱联用仪 (HPLC/ESI MS)、电子轰击质谱 (EI MS)和半制备型高效液相色谱 ,从卷丹百合中筛选出了两种甾体皂甙 ,其中一种为含有 3个糖基与提果皂甙元的甾体皂甙 ,另一种为含有 3个糖基和薯蓣皂甙元的甾体皂甙。结果表明 :在线的HPLC/ESI MS能够准确快速地提供糖甙类化合物的分子质量和糖链部分的有益信息 ,但对甙元部分提供的信息极少 ;离线的EI MS只需极少量 (1mg~ 2mg)的纯品就能准确地提供甙元部分的有益信息 ,但很难获得糖甙的分子离子峰与糖链部分的信息 ,两者有机地结合起来能快速地从植物中筛选甾体皂甙。  相似文献   

18.
Measurement of the ratio of testosterone (T) and epitestosterone (E) in urine has been used as an indication of 'natural' steroid supplementation for a decade. The direct measurement of the glucuronide and sulfate conjugates of testosterone and epitestosterone by high-performance liquid chromatography/tandem mass spectrometry (HPLC/MS/MS) should resolve a number of issues regarding unusual metabolism due to either genetic disposition or attempts to avoid detection of abuse. Determination of nanomoles per liter (0.1 ppb) concentrations of analytes in a complex biological matrix by HPLC/MS/MS is complicated by sample matrix-specific ion suppression during ESI. Deuterated internal standards of all compounds were used to overcome the effects of suppression. Comparison of the HPLC/MS/MS method with a two-part gas chromatographic/mass spectrometric method showed statistical equivalence in urine samples. Analysis of urine samples with elevated T-glucuronide to E-glucuronide ratios did not show that a significant number could be explained by an elevated excretion of epitestosterone sulfate. The HPLC/MS/MS method was also used further to characterize genetic and metabolic factors that give rise to unusual T/E ratios.  相似文献   

19.
A recently developed new and divergent approach for the solid‐phase synthesis of polyamines and polyamine derivatives was extended to the preparation of linear pentamines, and it was applied to the synthesis of three quartets of isomeric polyamine spider toxins. The twelve synthetic acylpolyamines were investigated by HPLC‐UV(DAD)‐MS and HPLC‐UV(DAD)‐MS/MS and compared with the natural products in the complex mixture of the venom of Agelenopsis aperta. The comparative investigation supported the structures and assignments of seven previously found toxins and allowed the identification of an additional five polyamine derivatives in the natural sample. The MS/MS study of the isomerically pure polyamine derivatives revealed furthermore a characteristic pattern for the fragmentation of these compounds, which can possibly be used as evidence in the trace analysis of other polyamine derivatives.  相似文献   

20.
Tandem MS techniques have been used to examine the formation of cluster ions derived from organotin compounds of environmental significance. The cluster formation was based on the addition of either water or methanol molecules (common HPLC solvents) to a cationic species derived from the organotin compound. For the compounds and conditions studied, cluster adducts were only observed from trisubstituted tin cations. The results show that, in high-pressure ionization methods used in the interface between HPLC and MS, the tin atom may be associated with a range of ions depending on the system parameters, and that care should be taken if selection ion monitoring (SIM) is to be used.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号