首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
A second generation ionic liquid matrix (ILM), N,N‐diisopropylethylammonium α‐cyano‐4‐hydroxycinnamate (DEA‐CHCA), was developed for the characterization of polar biodegradable polymers. It is compared with five solid matrices typically used for the characterization of these polymers and one other new ILM. It is shown that use of the ILM, DEA‐CHCA, allows maximum signal with minimum laser intensity which minimizes polymer degradation. In these conditions, the DEA‐CHCA ILM is able to assist in the ionization of analytes in an efficient but soft manner. These qualities produce spectra that allow an accurate and sensitive determination of the number average molecular weights, weight average m.w., and polydispersity index of labile polar polymers. With such polymers, many solid matrices produce spectra showing extensive polymer degradation leading to the underestimation of molecular weights. The distribution of intact analyte peaks obtained with the ILM DEA‐CHCA allows for identification of the fine structure of complex copolymers. ILMs were much less susceptible to effects of extraction delay times on molecular weight determination than were solid matrices. The liquid nature of the matrix is an important reason for the outstanding results obtained for labile analyte polymers. No comparable results could be obtained with any known solid matrices or other ILMs. In many cases, the manufacturers' listed molecular weights and polydispersity measurements for biodegradable polymers are determined by size‐exclusion chromatography and the data obtained by that method may differ considerably from the high‐precision matrix‐assisted laser desorption/ionization time‐of‐flight mass spectrometry (MALDI‐TOF‐MS) results presented here. Copyright © 2009 John Wiley & Sons, Ltd.  相似文献   

2.
In-source decay (ISD) and post-source decay (PSD) of a peptide ion ([Y6 + H]+) and a preformed ion (benzyltriphenylphosphonium, BTPP) generated by matrix-assisted laser desorption ionization (MALDI) were investigated with time-of-flight mass spectrometry. α-Cyano-4-hydroxycinammic acid (CHCA) and 2,5-dihydroxybenzoic acid (DHB) were used as matrices. For both ions, ISD yield was unaffected by delay time, indicating rapid termination of ISD. This was taken as evidence for rapid expansion cooling of hot “early” plume formed in MALDI. CHCA was hotter than DHB for [Y6 + H]+ while the matrix effect was insignificant for BTPP. The “early” plume temperature estimated utilizing previous kinetic results was 800–900 K, versus 400–500 K for “late” plume. The results support our previous finding that the temperature of peptide ions interrogated by tandem mass spectrometry was lower than most rough estimates of MALDI temperature.  相似文献   

3.
We present experimental matrix-assisted laser desorption/ionization time-of-flight (MALDI-TOF) results comparing a liquid (glycerol/K(4)[Fe(CN)(6)]) and a solid matrix (2,5-dihydroxybenzoic acid, DHB) with respect to analyte signal stability and initial ion velocity. For applications requiring stable production of analyte ions over a long period of time, the liquid matrix is superior to the solid matrix. The stable analyte ion signal obtained from a liquid matrix allowed the measurement of collision cross sections of small poly(ethylene glycol) (PEG(n)) adduct ions in the flight tube with good resolution. The initial velocity of these adduct ions was measured. It was found that analyte molecules from the liquid matrix have initial ion velocities significantly smaller than those from the solid matrix. MALDI-TOF measurements for large molecules using a liquid matrix are therefore likely to result in smaller systematic errors in mass calibrations due to initial ion velocity.  相似文献   

4.
Three different types of fullerene derivatives, namely methano[60]fullerene dicarboxylate esters, [60]fulleropyrrolidines, and imino[60]fullerenes, were analyzed by matrix‐assisted laser desorption/ionization time‐of‐flight mass spectrometry using trans‐4‐tert‐butyl‐4′‐nitrostilbene (TBNS), 1,8,9‐anthracenetriol (dithranol), 6‐aza‐2‐thiothymine (ATT), 2,5‐dihydroxybenzoic acid (DHB) and carbazole as matrices. Unit mass resolution (sufficient to clearly resolve isotopic peaks), high signal‐to‐noise ratio, and clean mass spectra for all analytes were acquired by the optimization of experimental parameters and choice of optimal solvent for the matrix and molar matrix‐to‐analyte ratio. The new matrix, TBNS, gave the best results in the positive‐ion mode, as it can provide higher yields of analyte molecular ions at a lower laser threshold than the other four matrices, together with a very low degree of unwanted fragmentations. In the negative‐ion mode dithranol was better than TBNS, and the other three matrices gave relatively poor mass spectra for these fullerene derivatives. Copyright © 2005 John Wiley & Sons, Ltd.  相似文献   

5.
We introduce a two-component matrix for ultraviolet matrix-assisted laser desorption/ionization mass spectrometry (UV-MALDI-MS) that consists of 2,5-dihydroxybenzoic acid (DHB) and glycerol. Upon slow evaporation of residual water/methanol solvents in a pre-vacuum chamber sample preparations are obtained that exhibit a homogeneous morphology with analyte-matrix crystals evenly distributed over the whole sample spot. At a molar DHB/glycerol ratio of approximately 1:5, the crystals range in length from approximately 100 to 300 microm and are about 15-30 microm wide. Mass spectra of peptides, proteins, and an oligosaccharide are presented and compared with those recorded from standard dried-droplet DHB matrix. The ion signals show a reproducibility of the order of 10-15% when scanning the surface of an individual sample or even different samples that contain the same amount of peptide, A close to linear relationship between peptide concentration and the corresponding peptide ion signal is found over three orders of magnitude of sample prepared. However, when a fixed position is irradiated with a large number of laser pulses, a monotonous decay of peptide ion signal with time is observed. Potentially, the binary matrix will be especially useful for the analysis of samples that are stabilized in buffered aqueous glycerol solution and preliminary results addressing this aspect are shown.  相似文献   

6.
This study demonstrates the application of 2,5-dihydrohybenzoic acid/aniline (DHB/An) and 2,5-dihydroxybenzoic acid/N,N-dimethylaniline (DHB/DMA) matrices for automated identification and quantitative analysis of native oligosaccharides by matrix-assisted laser desorption/ionization mass spectrometry (MALDI-MS). Both matrices are shown to be superior to pure DHB for native glycans in terms of signal intensities of analytes and homogeneity of sample distribution throughout the crystal layer. On-target formation of stable aniline Schiff base derivatives of glycans in DHB/An and the complete absence of such products in the mass spectra acquired in DHB/DMA matrix provide a platform for automated identification of reducing oligosaccharides in the MALDI mass spectra of complex samples. The study also shows how enhanced sensitivity is achieved with the use of these matrices and how the homogeneity of deposited sample material may be exploited for quick and accurate quantitative analysis of native glycan mixtures containing neutral and sialylated oligosaccharides in the low-nanogram to mid-picogram range.  相似文献   

7.
Application of matrix‐assisted laser‐desorption/ionization mass spectrometry (MALDI MS) to analysis and characterization of phosphopeptides in peptide mixtures may have a limitation, because of the lower ionizing efficiency of phosphopeptides than nonphosphorylated peptides in MALDI MS. In this work, a binary matrix that consists of two conventional matrices of 3‐hydroxypicolinic acid (3‐HPA) and α‐cyano‐4‐hydroxycinnamic acid (CCA) was tested for phosphopeptide analysis. 3‐HPA and CCA were found to be hot matrices, and 3‐HPA not as good as CCA and 2,5‐dihydroxybenzoic acid (DHB) for peptide analysis. However, the presence of 3‐HPA in the CCA solution with a volume ratio of 1:1 could significantly enhance ion signals for phosphopeptides in both positive‐ion and negative‐ion detection modes compared with the use of pure CCA or DHB, the most common phosphopeptide matrices. Higher signal intensities of phosphopeptides could be obtained with lower laser power using the binary matrix. Neutral loss of the phosphate group (?80 Da) and phosphoric acid (?98 Da) from the phosphorylated‐residue‐containing peptide ions with the binary matrix was decreased compared with CCA alone. In addition, since the crystal shape prepared with the binary matrix was more homogeneous than that prepared with DHB, searching for ‘sweet’ spots can be avoided. The sensitivity to detect singly or doubly phosphorylated peptides in peptide mixtures was higher than that obtained with pure CCA and as good as that obtained using DHB. We also used the binary matrix to detect the in‐solution tryptic digest of the crude casein extracted from commercially available low fat milk sample, and found six phosphopeptides to match the digestion products of casein, based on mass‐to‐charge values and LIFT TOF‐TOF spectra. Copyright © 2009 John Wiley & Sons, Ltd.  相似文献   

8.
The use of collision-induced dissociation, postsource decay (CID-PSD) matrix-assisted laser desorption/ionization (MALDI) mass spectrometry for the analysis of small organic molecules is demonstrated. Three pesticides: paraquat, diquat, and difenzoquat were chosen for this study. The matrices 2,5-dihydroxybenzoic acid (DHB), alpha-cyano-4-hydroxycinnamic acid (alpha-CHCA), and sinapinic acid (SA) were selected to investigate the effect of the matrix on the CID-PSD MALDI spectra of these molecules. Alpha-CHCA and DHB were found to be appropriate matrices for the pesticides studied. Spectra for a given pesticide obtained from different matrices were compared with each other, and the differences between them are discussed. A comparison of CID-PSD MALDI with fast-atom bombardment MS/MS spectra is presented; the agreement of pesticide fragmentation patterns between the two methods indicates that CID-PSD MALDI MS is a reliable and efficient technique for structural elucidation of small molecules.  相似文献   

9.
A variety of surfactants have been tested as matrix-ion suppressors for the analysis of small molecules by matrix-assisted laser desorption/ionization time-of flight mass spectrometry. Their addition to the common matrix alpha-cyano-4-hydroxycinnamic acid (CHCA) greatly reduces the presence of matrix-related ions when added at the appropriate mole ratio of CHCA/surfactant, while still allowing the analyte signal to be observed. A range of cationic quaternary ammonium surfactants, as well as a neutral and anionic surfactant, was tested for the analysis of phenolics, phenolic acids, peptides and caffeine. It was found that the cationic surfactants, particularly cetyltrimethylammonium bromide (CTAB), were suitable for the analysis of acidic analytes. The anionic surfactant, sodium dodecyl sulfate, showed promise for peptide analysis. For trialanine, the detection limit was observed to be in the 100 femtomole range. The final matrix/surfactant mole ratio was a critical parameter for matrix ion suppression and resulting intensity of analyte signal. It was also found that the mass resolution of analytes was improved by 25-75%. Depth profiling of sample spots, by varying the number of laser shots, revealed that the surfactants tend to migrate toward the top of the droplet during crystallization, and that it is likely that the analyte is also enriched in this surface region. Here, higher analyte/surfactant concentration would reduce matrix-matrix interactions (known to be a source of matrix-derived ions).  相似文献   

10.
The performance of a matrix‐assisted laser desorption/ionization (MALDI) ionic liquid matrix (ILM) consisting of α‐cyano‐4‐hydroxycinnamic acid (CHCA) and aniline (ANI) was evaluated to assess whether it could offer possible advantages over conventional matrices. Ultraviolet (UV), Fourier transform infrared (FTIR), nuclear magnetic resonance (NMR) and laser desorption/ionization mass spectrometry (LDI‐MS) experiments were carried out with the aim of confirming the structure of the ANI‐CHCA ILM. Different model analytes such as amino acids, peptides, proteins, lipids, phospholipids, synthetic polymers, and sugars were tested. Mass spectra with similar or improved signal‐to‐noise (S/N) ratio (compared to CHCA) were invariably obtained demonstrating the potential of this ILM as a general purpose matrix. Furthermore, protein identification by peptide mass fingerprinting (PMF) and database search was facilitated compared to CHCA since higher scores and increased sequence coverage were observed. Finally, a complex lipid mixture (i.e. a raw extract of a milk sample) analysed by MALDI‐MS showed improved S/N ratio, a reduced chemical noise and a limited formation of matrix‐clusters. Copyright © 2009 John Wiley & Sons, Ltd.  相似文献   

11.
High-sensitivity, high-throughput analysis of proteins for proteomics studies is usually performed by polyacrylamide gel electrophoresis in combination with mass spectrometry. However, the quality of the data obtained depends on the in-gel digestion procedure employed. This work describes an improvement in the in-gel digestion efficiency for matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOFMS) analysis. A dramatic improvement in the coverage of tryptic peptides was observed when n-octyl glucoside was added to the buffer. Whole cell extracted proteins from S. cerevisiae were separated by two-dimensional gel electrophoresis and stained with silver. Protein spots were identified using our improved in-gel digestion method and MALDI-TOFMS. In addition, the mass spectra obtained by using the matrix alpha-cyano-4-hydroxycinnamic acid (CHCA) were compared with those obtained using 2,5-dihydroxybenzoic acid (DHB). The DHB matrix usually gave more peaks, which led to higher sequence coverage and, consequently, to higher confidence in protein identification. This improved in-gel digestion protocol is simple and useful for protein identification by MALDI-TOFMS.  相似文献   

12.
A low molecular mass polyester was analyzed by desorption/ionization on porous silicon (DIOS) mass spectrometry. The results were compared with those of matrix-assisted laser desorption ionization (MALDI) mass spectrometry using matrixes of alpha-cyano-4-hydroxycinnamic acid (CHCA) and 10,15,20-tetrakis(pentafluorophenyl)porphyrin (F20TPP). The CHCA matrix was not suitable for characterization of low molecular mass components of the polyester because the matrix-related ions interfered with the component ions. On the other hand, the F20TPP matrix showed no interference because no matrix-related ions appeared below m/z 822. However, the solvent selection for determining optimal conditions of sample preparation was limited, because F20TPP does not dissolve readily in any of the available organic solvents. In the DIOS spectra, the polymer ions were observed at high sensitivity without a contaminating ion. No matrix is needed for DIOS spectra of low molecular mass polyesters, facilitating sample preparation and selectivity of a precursor ion in post-source decay measurements.  相似文献   

13.
Matrix-assisted laser desorption/ionization mass spectrometry (MALDI-MS) is a powerful tool for the analysis and characterization of protein phosphorylation on the peptide level. In this study, the applicability of ionic liquid matrices (ILM) formed by combination of the crystalline MALDI matrix 2,5-dihydroxybenzoic acid (DHB) with pyridine or n-butylamine was tested for the analysis of phosphopeptides. Low ionization efficiency in both positive and negative ion mode was observed in acid-free sample preparations. Upon addition of 0.1% trifluoroacetic acid (TFA), ion formation was increased, but analogously to the situation described earlier for pure DHB, best results were obtained upon use of 1% phosphoric acid as matrix additive. The samples prepared in this way were significantly more homogeneous than preparations with pure DHB, thus avoiding the need for time-consuming search for hot spots. Other characteristics like metastable fragmentation of phosphopeptides did not differ from that observed in classical preparations. The limits of detection for synthetic phosphopeptides and singly or multiply phosphorylated peptides from tryptic digests of alpha- and beta-casein were comparable with those obtained when using pure DHB; in some cases even higher signal intensities could be observed in the ILM. The use of ILM in combination with 1% phosphoric acid as matrix additive significantly facilitates analysis of phosphopeptides by MALDI-MS.  相似文献   

14.
Matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOFMS) was applied to the analysis of Ru(OCOCF(3))(2)(CO)(PPh(3))(2), Ru(OCOC(3)F(7))(2)(CO)(PPh(3))(2), Ir(tBuppy)(3) and Ir(ppy)(2)(acac) complexes. A troublesome problem in the MALDI-TOFMS characterization of these metal complexes is the possible replacement of complex ligands by matrix. In this contribution, 10 matrices, ranging from acidic to basic, were investigated: alpha-cyano-4-hydroxycinnamic acid (CHCA), 2,5-dihydroxybenzoic acid (DHB), sinapinic acid (SA), dithranol, 2,4,6-trihydroxyactophenone (THAP), 6-azo-2-thiothymine (ATT), norharman, 2-[(2E)-3-(4-tert-butylphenyl)-2-methylprop-2-enylidene]malononitrile (DCTB), 4-nitroaniline (NA) and 2-amino-5-nitrophyridine (ANP). With most of the matrices, including the neutral and basic ones, matrix substitution of ligand could clearly be detected. Based on the experimental results, possible mechanisms of matrix substitution were discussed. It was demonstrated that the ligand exchange process might also occur through the gas-phase reactions initiated by laser shots. Among the matrices tested, DCTB was found to be the best one for the complexes that are prone to ligand exchange by matrix.  相似文献   

15.
For matrix‐assisted laser desorption/ionization (MALDI) mass spectra, undesirable ion contamination can occur due to the direct laser excitation of substrate materials (i.e., laser desorption/ionization (LDI)) if the samples do not completely cover the substrate surfaces. In this study, comparison is made of LDI processes on substrates of indium and silver, which easily emit their own ions upon laser irradiation, and conventional materials, stainless steel and gold. A simultaneous decrease of ion intensities with the number of laser pulses is observed as a common feature. By the application of an indium substrate to the MALDI mass spectrometry of alkali salts and alkylammonium salts mixed with matrices, 2,5‐dihydroxybenzoic acid (DHB) or N‐(4‐methoxybenzylidene)‐4‐butylaniline (MBBA), the mixing of LDI processes can be detected by the presence of indium ions in the mass spectra. This method has also been found to be useful for investigating the intrinsic properties of the MALDI matrices: DHB samples show an increase in the abundance of fragment ions of matrix molecules and cesium ions with the number of laser pulses irradiating the same sample spot; MBBA samples reveal a decrease in the level of background noise with an increase in the thickness of the sample layer. Copyright © 2009 John Wiley & Sons, Ltd.  相似文献   

16.
D-Glucose and 19 glucose derivatives were investigated by positive and negative ion matrix assisted laser desorption/ionization time-of-flight mass spectrometry using 2,5-dihydroxybenzoic acid (DHB) as the matrix. The set of substrates includes oligomers of amylose and cellulose, native alpha-, beta-, and gamma-cyclodextrin, and chemically modified beta- and gamma-cyclodextrins. These analytes were chosen to modulate molecular weight, polarity, and capability of establishing noncovalent interactions with guest molecules. In the negative-ion mode, the DHB matrix gave rise to charged multicomponent adducts of type [M + DHB - H]- (M = oligosaccharide) selectively for those analytes matching the following conditions: (i) underivatized chemical structure and (ii) number of glucose units > or = 4. In the positive-ion polarity, only some amylose and cellulose derivatives and methylated beta-cyclodextrins provided small amount of cationized adducts with the matrix of type [M + DHB + X]+ (X = Na or K), along with ubiquitous [M + X]+ ions. The results are discussed by taking into account analyte-matrix association phenomena, such as hydrogen bond and inclusion phenomena, as a function of the molecular structure of the analyte. The conclusions derived by mass spectrometric data are compared with the X-ray diffraction data obtained on a single crystal of the 1:1 alpha-cyclodextrin - DHB noncovalent adduct.  相似文献   

17.
Direct mass spectrometric analysis of complex biological samples is becoming an increasingly useful technique in the field of proteomics. Matrix-assisted laser desorption/ionization mass spectroscopy (MALDI-MS) is a rapid and sensitive analytical tool well suited for obtaining molecular weights of peptides and proteins from complex samples. Here, a fast and simple approach to cellular protein profiling is described in which mammalian cells are lysed directly in the MALDI matrix 2,5-dihydroxybenzoic acid (DHB) and mass analyzed using MALDI-time of flight (TOF). Using the unique MALDI mass spectral "fingerprint" generated in these analyses, it is possible to differentiate among several different mammalian cell lines. A number of techniques, including MALDI-post source decay (PSD), MALDI tandem time-of-flight (TOF-TOF), MALDI-Fourier transform ion cyclotron resonance (FTICR), and nanoflow liquid chromatography followed by electrospray ionization and tandem mass spectrometry (LC-ESI-MS/MS) were employed to attempt to identify the proteins represented in the MALDI spectra. Performing a tryptic digestion of the supernatant of the cells lysed in DHB with subsequent LC-ESI-MS/MS analysis was by far the most successful method to identify proteins.  相似文献   

18.
Due to the characteristic absorption peaks in the IR region, various molecules can be used as a matrix for infrared matrix‐assisted laser desorption/ionization (IR‐MALDI). Especially in the 6–7 µm‐band IR region, solvents used as the mobile phase for liquid chromatography have absorption peaks that correspond to their functional groups, such as O–H, CO, and CH3. Additionally, atmospheric pressure (AP) IR‐MALDI, which is applicable to liquid‐state samples, is a promising technique to directly analyze untreated samples. Herein we perform AP‐IR‐MALDI mass spectrometry of a peptide, angiotensin II, using a mid‐IR tunable laser with a tunable wavelength range of 5.50–10.00 µm and several different matrices. The wavelength dependences of the ion signal intensity of [M + H]+ of the peptide are measured using a conventional solid matrix, α‐cyano‐4‐hydroxycinnamic acid (CHCA) and a liquid matrix composed of CHCA and 3‐aminoquinoline. Other than the O–H stretching and bending vibration modes, the characteristic absorption peaks are useful for AP‐IR‐MALDI. Peptide ions are also observed from an aqueous solution of the peptide without an additional matrix, and the highest peak intensity of [M + H]+ is at 6.00 µm, which is somewhat shorter than the absorption peak wavelength of liquid water corresponding to the O–H bending vibration mode. Moreover, long‐lasting and stable ion signals are obtained from the aqueous solution. AP‐IR‐MALDI using a 6–7 µm‐band IR tunable laser and solvents as the matrix may provide a novel on‐line interface between liquid chromatography and mass spectrometry. Copyright © 2015 John Wiley & Sons, Ltd.  相似文献   

19.
Fine metal or metal oxide powder as an alternative to conventional organic matrices in matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOFMS) has been utilized successfully for lower molecular mass analytes, poly(ethylene glycol) 200 (PEG 200) and methyl stearate. Eleven kinds of particle, Al, Mn, Mo, Si, Sn, SnO2, TiO2, W, WO3, Zn and ZnO, were evaluated. The analyte was mixed with a metal or metal oxide powder (inorganic matrix) with particle diameter of tens of micrometers and liquid dispersant, followed by application to the sample target. Using a commercial MALDI-TOFMS instrument equipped with an internal 337 nm pulsed nitrogen laser, the analytes, PEG 200 and methyl stearate, were ionized as the alkali metal ion adducted molecules [M+Na]+ or [M+K]+ when the inorganic matrices Mn, Mo, Si, Sn, TiO2, W, WO3, Zn or ZnO were used. In the case of an Al matrix, PEG 200 was ionized as [M+K]+, whereas methyl stearate was ionized as [M+H]+ and [M+Al]+. These particles have potential as the matrix for MALDI. During our examination, however, only SnO2 particles did not ionize either PEG 200 or methyl stearate. Based on our protocol, when TiO2 powder was suspended with liquid paraffin, PEG 200 and methyl stearate gave their MALDI-TOF mass spectra with the lowest background noise and highest intensity. TiO2 powder seemed to be a broad potential matrix for low molecular mass polar or non-polar analytes. The results suggested that bulk particles caused rapid heating/vaporization processes and ionized analyte molecules under irradiation with a pulsed UV laser. The present method can be readily applied to obtain the low background noise MALDI-TOF mass spectra of small-sized compounds.  相似文献   

20.
The applicability of matrix-assisted laser desorption/ionization time of flight mass spectrometry (MALDI-TOF MS) to the analysis of wax esters (WEs) was investigated. A series of metal salts of 2,5-dihydroxybenzoic acid (DHB) was synthesized and tested as possible matrices. Alkali metal (Li, Na, K, Rb, Cs) and transition metal (Cu, Ag) salts were studied. The matrix properties were evaluated, including solubility in organic solvents, threshold laser power that should be applied for successful desorption/ionization of WEs, the nature of the matrix ions and the mass range occupied by them, and the complexity of the isotope clusters for individual metals. Lithium salt of dihydroxybenzoic acid (LiDHB) performed the best and matrices with purified lithium isotopes ((6)LiDHB or (7)LiDHB) were recommended for WEs. Three sample preparation procedures were compared: (1) mixing the sample and matrix in a glass vial and deposition of the mixture on a MALDI plate (Mix), (2) deposition of sample followed by deposition of matrix (Sa/Ma), and (3) deposition of matrix followed by deposition of sample (Ma/Sa). Morphology of the samples was studied by scanning electron microscopy. The best sample preparation technique was Ma/Sa with the optimum sample to matrix molar ratio 1 : 100. Detection limit was in the low picomolar range. The relative response of WEs decreased with their molecular weight, and minor differences between signals of saturated and monounsaturated WEs were observed. MALDI spectra of WEs showed molecular adducts with lithium [M + Li](+). Fragments observed in postsource decay (PSD) spectra were related to the acidic part of WEs [RCOOH + Li](+) and they were used for structure assignment. MALDI with LiDHB was used for several samples of natural origin, including insect and plant WEs. A good agreement with GC/MS data was achieved. Moreover, MALDI allowed higher WEs to be analyzed, up to 64 carbon atoms in Ginkgo biloba leaves extract.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号