首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 9 毫秒
1.
2.
An improved high-performance liquid chromatographic method for the simultaneous determination of caffeine and its three primary metabolites (theophylline, theobromine and paraxanthine) in human plasma is described. The four substances were separated on a reversed-phase column (5 microns TSK gel ODS-80TM, 150 mm x 4.6 mm I.D.) by use of the mobile phase methanol-0.1 M NaH2PO4 (30:70, v/v) with a flow-rate of 0.8 ml/min. Absorbance was monitored at 274 nm. The detection limit was 5 ng/ml for theobromine and caffeine and 10 ng/ml for paraxanthine and theophylline. The linearity and reproducibility were sufficient for drug monitoring of caffeine and its primary methylxanthines.  相似文献   

3.
气相色谱-质谱法同时快速测定血清中5种剧毒灭鼠剂   总被引:1,自引:0,他引:1  
黄会秋  黄逊  余惊笋 《色谱》2015,33(3):323-328
建立了同时快速测定血清样品中毒鼠强、氟乙酰胺、氟乙酸钠、甘氟Ⅰ与甘氟Ⅱ 5种灭鼠剂的气相色谱-质谱联用法。在pH 2.0条件下,以N,N-二乙基对苯二胺为衍生剂,N,N'-二环己基碳二亚胺为催化剂,氟乙酸钠在室温下振荡衍生5 min,衍生物与毒鼠强、氟乙酰胺、甘氟Ⅰ、甘氟Ⅱ一并被乙酸乙酯萃取,经50 ℃下氮吹浓缩后用气相色谱-质谱同时测定,采用选择离子监测(SIM)模式,基质标准外标法定量。方法选用SLB-IL59离子液体毛细管柱(30 m×0.25 mm×0.20 μm,最高温度:300 ℃),流速1.0 mL/min,经程序升温在15 min内成功地分离了5种灭鼠剂。结果显示,血清中氟乙酰胺的线性范围为0.02~2.0 mg/L,毒鼠强的线性范围为0.02~10 mg/L,其他目标物的线性范围为0.01~1.0 mg/L;检出限为0.001~0.002 mg/L (S/N=3),相关系数R2>0.995。在3个加标水平下,方法加标回收率介于84.0%和110.0%之间,相对标准偏差(n=6)介于2.9%和7.5%之间。方法操作简便、准确,灵敏度高,适于中毒病人的快速诊断检测。  相似文献   

4.
An efficient and sensitive method for simultaneous determination of 118 pesticide residues in teas has been established and validated. A multi-residue analysis of pesticides in tea involved extraction with ethyl acetate-hexane, clean-up using gel permeation chromatography (GPC) and solidphase extraction (SPE), and subsequent identification and quantification of the selected pesticides by gas chromatography-mass spectrometry (GC-MS). For most of the target analytes, optimized pretreatment processes led to no significant interference with analysis of sample matrix, and the determination of 118 compounds was achieved in about 60 min. In the linear range of each pesticide, the correlation coefficient was R 2 ≥ 0.99. At the low, medium and high three fortification levels of 0.05–2.5 mg kg−1, 118 pesticides average recoveries range from 61 % to 121 % and relative standard deviations (RSD) were in the range of 0.6–9.2 % for all analytes. The limits of detection for the method were 0.00030-0.36 mg kg−1, depending on each pesticide.  相似文献   

5.
The gas chromatography/mass spectrometric assay method was developed for the determination of 13 non‐steroidal anti‐inflammatory drugs (NSAIDs) in river water. Extraction was achieved by a liquid‐phase extraction procedure using methylene chloride. The extract was reacted for 30 min at 80°C based on the formation of methyl ester with 1.0 M HCl in methanol and extraction of the derivative with ethyl acetate, which was then measured by gas chromatography‐mass spectrometry. The limit of quantification of NSAIDs was 1.0–60 ng/L and the calibration curve showed linearity being greater than r=0.997. The method was used to analyze ten river water samples from various regions in Korea. Diclofenac, indoprofen, ketoprofen and loxoprofen were detected at concentration of up to 1.29 μg/L in river water. The developed method may prove valuable for use in the national monitoring project of NSAIDs in surface water.  相似文献   

6.
A novel method has been developed to simultaneously determine and quantify seven organic UV filters employing liquid (solid)-liquid extraction, derivatization with N-methyl-N-(trimethylsilyl) trifluoroacetamide (MSTFA) and gas chromatography with mass spectrometric detection in various environmental matrices. The UV filters determined were: benzophenone (BP), benzhydrol (BH), 4-hydroxybenzophenone (HBP), 2-hydroxy-4-methoxybenzophenone (HMB), 2,4-dihydroxybenzophenone (DHB), 2,2'-dihydroxy-4-methoxybenzophenone (DHMB) and 2,3,4-trihydroxylbenzophenone (THB). Under optimal conditions, the analysis required 23 min and good linearity over the range of 10-2,500 ng/L in water and 100-25,000 ng/kg in soil for each UV filter obtained. The high recovery (62-114% and 60-125% for water and soil samples, respectively) and the low RSD values (less than 13.9 and 17.2% for water and soil samples, respectively) indicated the high performance of this method. The method detection limits (MDLs) were relatively low, ranging from 5 to 100 ng/L or kg and quantification limits ranged between 25 and 500 ng/L or kg for all test compounds. This validated method was applied in the analysis of seven BP-type UV filters collecting water and soil samples in Korea, between April and May 2003. The overall concentration of UV filters in the soil sample (500-18,380 ng/kg) was highly distributed in water sample (27-204 ng/L). The established method was successfully applied to monitor the residue measurement of the BP-type UV filters in environmental water and soil samples.  相似文献   

7.
A simple and effective method has been developed to simultaneously determine endocrine-disrupting phenolic xenoestrogens and steroid estrogens in sediment by using ultra-sonicated extraction in combination with silica gel fractionation, derivatization with pentafluropropionic anhydride, and gas chromatography-mass spectrometry (GC-MS) in selected ion monitoring mode (SIM). Satisfactory recoveries have been obtained for phenolic xenoestrogens and steroid estrogens. The method enables the determination of targets at concentrations of lower nanogram-per-gram in sediments. The method has been successfully applied to the sediments collected from Pearl River Estuary (PRE), South China Sea, China. Nonylphenol and bisphenol-A (BPA) were detected in the range from 204.2 to 664.5 ng/g and 0.6 to 4.0 ng/g, respectively. None of the estrogens were found in the sediment samples.  相似文献   

8.
建立了采用气相色谱-质谱(GC-MS)同时测定水果中9种保鲜剂残留量的分析方法。水果样品用正己烷/乙酸乙酯(1/1,v/v)混合提取剂超声提取,经Florisil层析柱净化后用正己烷/乙酸乙酯(1/3,v/v)混合洗脱剂洗脱,以磷酸三苯脂(TPP)为内标物,采用GC-MS的全扫描方式(SCAN)和选择离子监测方式(SIM)对9种保鲜剂进行定性与定量分析。实验结果表明,9种保鲜剂的检出限(LOD)为0.10~2.16μg/kg,在50、100、200μg/kg添加水平下的回收率为75.3%~128%,相对标准偏差为1.57%~11.6%。本分析方法样品前处理简便,净化效果明显,在SIM谱图中分析目标物响应值大、灵敏度高,定量准确可靠,能够满足保鲜剂痕量残留的检测要求。  相似文献   

9.
D-Serine is a co-agonist of the N-methyl-D-aspartate receptor in glutamate neurotransmission and has been proposed as a potential therapeutic agent for schizophrenia. However, D-serine also acts as a nephrotoxic substance in rats at high doses. To investigate the pharmacokinetics and toxicokinetics of D-serine, a method for the stereoselective determination of serine enantiomers in rat plasma was developed using GC-MS with selected ion monitoring (GC-MS-SIM). DL-[(2)H(3)]Serine was used as an internal standard to account for losses associated with the extraction, derivatization and chromatography. Serine enantiomers were purified by cation-exchange chromatography using BondElut SCX cartridge and derivatized with HCl in methanol to form methyl ester followed by subsequent N,O-diacylation with optically active (+)-α-methoxy-α-trifluoromethylphenylacetyl chloride to form epimeric amide. Quantitation was performed by SIM of the molecular-related ions of the epimers in the chemical ionization mode. The intra- and inter-day reproducibility of the assay was less than 5% for D-serine and 3% for L-serine. The method was successively applied to study the pharmacokinetics of D-serine in rats.  相似文献   

10.
曾凯  刘峙嵘  宁雅君  李金林  唐俊  张敏 《色谱》2013,31(5):477-480
建立了同时测定乳制品中三聚氰胺及肌酐的气相色谱-质谱联用方法。样品经1%三氯乙酸溶液萃取,混合型阳离子交换固相萃取净化,提取液用氮气吹干后加入N,O-双(三甲基硅基)三氟乙酰胺-三甲基氯硅烷(BSTFA-TMCS)硅烷化试剂,于75 ℃下衍生60 min,最后采用选择离子模式下的气相色谱-质谱测定。三聚氰胺和肌酐的定量限分别为0.10 mg/kg和0.20 mg/kg;在0.1~50 mg/L范围内的线性相关系数均大于0.99。实际样品中,肌酐在10~100 mg/kg和三聚氰胺在0.1~5.0 mg/kg添加范围内的回收率分别为80.7%~116.8%和77.6%~107.5%,相对标准偏差分别小于9.4%和8.5%。该方法能有效除去干扰,灵敏度高,回收率较好,可用于乳制品中三聚氰胺和肌酐的同时测定。  相似文献   

11.
汤娟  费晓庆  周佳  钱凯  董绍伟  曹丽华  丁友超 《色谱》2021,39(3):324-330
建立了同时测定化妆品中18种氯代烃类有机溶剂的气相色谱-质谱(GC-MS)检测方法.样品在饱和氯化钠溶液中由正十四烷振荡提取后,以Agilent J&W DB-624超高惰性毛细管柱(30m×0.25 mm×1.4μm)为分离色谱柱进行分析,以电子轰击(EI)源、SIM模式进行质谱监测,外标法定量.结果 表明,18种化...  相似文献   

12.
A sensitive and selective method, using liquid chromatography-ionspray mass spectrometry, was developed and validated for the simultaneous determination of Estracyt (estramustine phosphate) and its four metabolites, estramustine, estromustine, estrone and estradiol, in human plasma. Deuterated internal standards were available for all analytes. The five compounds were extracted from plasma by protein precipitation with acetonitrile. The chromatographic separation was performed using a Zorbax SB C18, (150 x 4.6 mm i.d., 5 microm) reversed-phase column under gradient conditions with a mobile phase containing 2 mm ammonium acetate buffer (pH 6.8) and acetonitrile. MS detection was by electrospray ionization with multiple reaction monitoring in the positive ion mode for estramustine phosphate, estromustine and estramustine, and in the negative ion mode for estrone and estradiol. The limit of quantitation was 10 ng/mL for estramustine phosphate, 3 ng/mL for estromustine, estramustine and estrone and 30 ng/mL for estradiol. Linearity was verified from these LLOQs up to about 4000 ng/mL for the parent drug and 2000 ng/mL for the metabolites. Inter-day precision and accuracy values were all less than 15%. This assay was applied successfully to the routine analysis of human plasma samples collected in cancer patients administered estramustine phosphate intravenously.  相似文献   

13.
14.
气相色谱-质谱法同时测定化妆品中19种邻苯二甲酸酯   总被引:3,自引:0,他引:3  
Liang J  Zhuang W  Wei D  Ou Y  Gong Z 《色谱》2012,30(3):273-279
建立了同时测定化妆品中19种邻苯二甲酸酯的气相色谱-质谱(GC-MS)方法。样品经二氯甲烷超声提取后,用硅胶-中性氧化铝(2:3, m/m)混合填料固相小柱保留、乙酸乙酯-正己烷(8:2, v/v)洗脱等步骤净化后,采用GC-MS对19种目标物进行定性、定量分析。采用保留时间与特征离子丰度比共同进行定性分析,减少了复杂样品基质中的干扰。在优化的实验条件及0.1、0.5、2.0 μg/g的添加水平下,平均加标回收率为72.2%~110.9%,其中加标水平为0.1 μg/g的相对标准偏差(RSD, n=6)小于10.3%;方法检出限(以3倍标准偏差计)为0.0065 μg/g(邻苯二甲酸二异戊酯)~0.062 μg/g(邻苯二甲酸二异丁酯)之间。应用该方法检测了6种化妆品中19种PAEs的含量。该方法可推广用于多种类型化妆品中PAEs的测定。  相似文献   

15.
蔡立鹏  吕晓飞  张蓓  李小英  赵晓甫 《色谱》2019,37(1):111-115
建立了气相色谱-质谱同时检测果蔬清洗剂中12种防腐剂和抗氧化剂的方法。果蔬清洗剂样品先加入乙醇,经旋转蒸发除去样品中的水分,然后用正己烷饱和的乙腈溶液提取,饱和氯化钠溶液洗涤净化,净化后的样品溶液浓缩后用乙腈定容。被测组分经HP-5MS UI石英毛细管色谱柱(30 m×0.25 mm×0.25 μm)分离后在选择离子监测模式下测定。12种防腐剂和抗氧化剂在0.1~10 mg/L范围内线性关系良好,相关系数(r2)>0.999;检出限和定量限分别为0.010~0.030 mg/kg和0.030~0.090 mg/kg。按照建立的方法进行0.2、2.0和10 mg/kg 3个添加水平的加标回收试验,回收率为68.3%~115.3%,相对标准偏差为3.1%~11.3%。该法灵敏度高,定性准确,前处理净化效果好,适用于果蔬清洗剂中防腐剂和抗氧化剂的检测。  相似文献   

16.
17.
The metabolism of 19-nortestosterone was investigated in a miniature non-castrated male pig (boar), in a castrated pig (barrow) and in a female pig (sow). Urine samples were taken before and at regular intervals after the injection of 100 mg of Laurabolin (nortestosterone laurate). The sample clean-up consists in preliminary solid-phase extraction, followed by high-performance liquid chromatographic purification and fractionation. Finally, gas chromatography-mass spectrometry is used to identify the 19-nortestosterone metabolites.  相似文献   

18.
Conditions of the simultaneous isolation of various types of zolpidem metabolites from samples of real urine by solid-phase extraction have been optimized. Various derivatives of zolpidem hydroxy- and carboxy-metabolites were obtained; their mass-spectral and gas-chromatographic characteristics have been studied. The results ensure the reliable identification of zolpidem metabolites by gas chromatography-mass spectrometry for chemical toxicological and forensic investigations.  相似文献   

19.
A method for simultaneous determination of prostaglandin E2 (PGE2), prostaglandin F2 alpha (PGF2 alpha), 6-keto-prostaglandin F1 alpha (6-keto-PGF1 alpha), and thromboxane B2 (TxB2) in plasma was developed. After acidification and addition of 2H- and 3H-labelled internal standards, plasma prostanoids were extracted by reversed-phase cartridges and purified by normal-phase high-performance liquid chromatography. The pentafluorobenzyl, methoxime, trimethylsilyl derivatives were formed. Negative-ion chemical-ionization mass spectra with methane as reagent gas show one intense peak at m/z (M - pentafluorobenzyl). This ion was used for selective-ion monitoring. Prostanoid plasma concentrations (pg/ml) in five healthy volunteers were: PGE2 2.0-10.4, PGF2 alpha 2.2-9.8, 6-keto-PGF1 alpha 0.6-1.8, and TxB2 3.0-45.3. However, there is evidence that the TxB2 values may frequently be falsely high because of ex vivo production during the sampling procedure.  相似文献   

20.
刘永明  葛娜  王飞  李金  吴艳萍  黄学者  曹彦忠 《色谱》2012,30(8):782-791
建立了顶空气相色谱-质谱(HS-GC/MS)同时测定蜂蜜中57种挥发性有机溶剂(包括烷烃类、芳香烃类、醇类、酮类、酯类、醚类)残留量的分析方法。蜂蜜样品在密封的顶空瓶中用水溶解后,在顶空仪中于80 ℃下平衡30 min,使气-液两相达到动态平衡。采用DB-624毛细管色谱柱(60 m×0.25 mm×1.40 μm)对57种有机溶剂进行分离,GC/MS测定,外标法定量。该方法对于烷烃类、芳香烃类和醚类挥发性有机溶剂在0.005~0.2 μg、酯类0.05~2.0 μg、酮类0.5~20 μg、醇类2.5~100 μg范围内线性关系良好,相关系数均大于0.996。对于烷烃类、芳香烃类和醚类挥发性有机溶剂在1.0~20 μg/kg、酯类10~200 μg/kg、酮类100~2000 μg/kg、醇类500~10000 μg/kg添加范围内的平均添加回收率为61.0%~113.1%,相对标准偏差为1.9%~9.8%。对于烷烃类、芳香烃类和醚类挥发性有机溶剂的检出限为1.0 μg/kg、酯类10 μg/kg、酮类100 μg/kg、醇类500 μg/kg。该方法操作简单、快速,灵敏度和准确度高,适用于蜂蜜样品中多种挥发性有机溶剂残留量的同时检测。  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号