首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 156 毫秒
1.
Abolhassani,M.D.一:Hejazi,M.;Ah- madian,A.;and Amjadi,A.:Comparison of optieal deteetion system,PVDF deteetion system,and PVDF needle hydroPhone for oPtoacoustie tomograPh扒593 Ahmadian,人.see Abolhassani,M,D.,593 All劝 adi,A.see Abolhassani,M.D.,593 Bai,Ming see Zhang,Douguo,107 Bao,Huanmin see丫V么ng,Yanyong,4; W么ng,Yanyong,6;Jia,Doxlgfang,311 Bao,N.K.see Chen,Zhongyu,319 Bi,Jinzi see Yu,Ting,92 Bian,Jing see Xie,Hongyun,156 Bu,Ydng see …  相似文献   

2.
An,Geng see Liang,Gongying,59 B乙,Peng一;and Liu,Junhua:Mixture gas component eoneentration analysis based on supPort veetor maehine and infrared spee- trum,243 Bai,XiangZhong see Chen,Mingyang,63 Bi,Guojiong see Zhang,Shenjin,658 Bi,Jin活1 s  相似文献   

3.
ICP-AES法同时测定茶叶中的锌、铁、锰、铜、镍、镁   总被引:6,自引:0,他引:6  
研究了用硝酸+硫酸+高氯酸消解样品,用ICP-AES法同时测定茶叶中锌,铁,锰,铜,镍,镁的新方法,在选定的最佳条件下,测锌,铁,锰,铜,镍,镁的检出限分别为4.2,7.8,0.4,7.3,7.6,4.8ng.mL^-1,回收率为94.7%-104.2%,RSD为0.3%-4.7%,该法准确,快速,简便,适用于茶叶样品的测定,结果令人满意。  相似文献   

4.
ICP—AES法测定锌及其化合物中的杂质元素   总被引:3,自引:0,他引:3  
采用样品溶解后直接测定及氢氧化钇共沉淀将锌与被测杂质元素分离后测定相结合,研究了锌及其化合物中Ag,Co,Al,Ni,Fe,Cu,Cd,Cr,Mn,In,As,Pb,Sn,Sb,Bi等15个杂质元素的ICP-AES测定方法,相对标准偏差1.6-8.1%。  相似文献   

5.
半导体激光牙科治疗仪   总被引:2,自引:0,他引:2  
采用GaAlAs激光二极管作为激光源,电子定时,功率实时监测,LED红光指示,硬光纤偶合输出,工作波长830nm,输出功率130mW,属于低功率激光,主要产生刺激调理作用,消炎止痛,抗感染,改善血液循环,增强机体免疫功能  相似文献   

6.
元素在探针表面上的原子化机理研究   总被引:3,自引:0,他引:3  
探针原子人经法是一种新技术,本文系统地总结了用探针原子化法研究Au(1B),Sr(ⅡA),Cd(ⅡB),Al(ⅢA),La,Sm,Fu(ⅢB),Ge,Sn,Pb(ⅣA),Sb,Bi(ⅤA),V(ⅤB),Cr,Mo(ⅥB),Mn(ⅦB),Fe,Co,Ni,Pt(Ⅷ)等20个元素的原子化机理了起源于卤化物分解的元素有Au与Pt,起源于氧化物分解的元素有Cd,Al,La,Sm,Eu,Ge,Mn与Fe。  相似文献   

7.
中药方剂煎煮液中ICP—AES法同时测定16个元素   总被引:5,自引:0,他引:5  
本文提出了用硝酸-过氧化氢对中药方剂煎煮液进行处理,ICP-AES法对煎煮液中Li,Na,Be,Ca,Sr,Ba,Mg,Cu,Co,Ni,Zn,Mn,Cd,Fe,Cr,V16个元素进行同时测定的方法,该方法简单,快速,准确度高,所测元素的加标回收率均在85~103%之间,样品分析结果满意。  相似文献   

8.
X射线荧光光谱法测定硅酸盐中硫等20个主、次、痕量元素   总被引:39,自引:1,他引:39  
本文使用新研制的偏硼酸锂和四硼酸锂混合熔剂,在1000℃熔融制样,以X射线荧光光谱法测定硅酸盐等样品中的S,Na,Mg,Al,Si,P,K,Ca,Ti,Mn,Fe,Ba,Cr,V,Sr,Zr,Rb,Cu,Ni和Nb等20种元素,采用理论α系数和康普顿散射线作内标校正元素间的吸收-增强效应。其分析结果的精密度和准确度可与化学法相比  相似文献   

9.
探索一种简洁,直观,生动,易被工科学生所接受的混沌教学方法,特点在于利用多种媒体包括电子教案,光盘,VCD,网络,C语言程序,演示实验等,由浅入深,由表及里,向学生展示混沌世界。  相似文献   

10.
姜科植物化学成分的色谱/质谱研究   总被引:2,自引:0,他引:2  
本文研究了姜科植物11个样品,提取了挥发油,用色谱/质谱技术从挥发油中鉴定出100多种成分。其中α-蒎烯,β-蒎烯,莰烯1,8-桉油素,β-水芹烯,柠檬酸,柠檬醛,香叶醇,丁子香酚,芳樟醇,α-姜烯,β-姜烯,α-姜黄烯,β-姜黄烯,石竹烯,姜酮,β-荜澄茄烯,香芹酮,乙酸香叶酯,乙酸芳樟酯等20种化合物是多数姜科植物挥发油的共同成分。  相似文献   

11.
提出基于Te(Ⅳ)催化S2-还原亚甲基蓝褪色反应,建立了新的测定微量碲的动力学分析方法。研究了催化反应条件,并测定了催化反应的表观活化能为68.94 kJ·mol-1,反应速率常数为1.63×10-2 s-1。Te(Ⅳ)浓度在20~220 ng·mL-1范围内服从比尔定律,回归曲线的线性方程为y=0.003 8x+0.219 1,相关系数r=0.999 5,方法的检出限为3.04 ng·mL-1。应用于粗硒粉中微量碲的测定,相对标准偏差为3.1%(n=7),加标回收率为98.4%~100.4%。  相似文献   

12.
阿奇霉素含量的荷移光谱法测定   总被引:11,自引:0,他引:11  
用分光光度法分别研究了阿奇霉素与7,7,8,8-四氰基对二次甲基苯醌(TCNQ)和氯冉酸(CL)之间的荷移反应。实验表明:阿奇霉素与TCNQ间的反应在丙酮介质中进行,形成的络合物在743和842 nm有两个吸收峰,表观摩尔吸光系数分别是2.7×104 L·mol-1·cm-1和5.0×104 L·mol-1·cm-1;阿奇霉素与氯冉酸的反应在丙酮介质中进行,形成的络合物在530 nm处有吸收峰,表观摩尔吸光系数2.4×103 L·mol-1·cm-1。用摩尔比法和等摩尔连续变化法测得荷移络合物中阿奇霉素与配体的摩尔比均为1∶2。用以上两种方法测定了阿奇霉素片剂中阿奇霉素的含量,相对标准偏差为1.0%~1.4%(n=6),回收率为97%以上,与标准方法比较结果准确。  相似文献   

13.
通过研究在不同酸度下Sb5+对Se,Bi的干扰情况,发现在高酸度下,Sb对Se,Bi的干扰明显减弱,并结合锑在不同价态发生氢化反应的差异性,建立了不需通过任何化学分离而直接测定锑及其相关产品中的微量硒和铋的方法,并用于实际样品的分析.方法对实际样品加标回收率在95%~105%之间,检测下限(含量)硒和铋分别为0.00004×10-2mg@L-1和0.0001×10-1mg@L-1,对实际样品分析精度分别为RSD(Se)=2.4%(含量为0.00169×10-2mg@L-1时),5.4%(含量为0.00056×10-mg@L-1时)和RSD(Bi)=5.0%(含量为0.00024×10-2mg@L-1时),1.3%(含量为0.00229×10-2mg@L-1时),完全满足实际样品分析的要求.  相似文献   

14.
建立了血浆氨的靛酚蓝直接显色测定新方法,研究了介质酸度、显色时间、共存物质及抗凝剂等的影响。结果表明,以柠檬酸钠作抗凝剂,在pH 10.5~11.2的磷酸盐缓冲体系中显色强度高,干扰小。有色化合物最大吸收波长位于630 nm,表观摩尔吸光系数为2.48×104 L·mol-1·cm-1。血浆氨浓度在0~1 500 μmol·L-1范围线性关系良好(r=0.999 9),检测下限为1.7 μmol·L-1,相对标准偏差RSD为1.13%(n=11),回收率为93.6%~101.6%,平均回收率97.0%。用本法测定43例正常人和97例各型肝病患者血浆氨含量均获得满意结果。  相似文献   

15.
We report results of a study of the B(s)(0) oscillation frequency using a large sample of B(s)(0) semileptonic decays corresponding to approximately 1 fb(-1) of integrated luminosity collected by the D0 experiment at the Fermilab Tevatron Collider in 2002-2006. The amplitude method gives a lower limit on the B(s)(0) oscillation frequency at 14.8 ps(-1) at the 95% C.L. At delta m(s) = 19 ps(-1), the amplitude deviates from the hypothesis A= 0(1) by 2.5 (1.6) standard deviations, corresponding to a two-sided C.L. of 1% (10%). A likelihood scan over the oscillation frequency, delta m(s), gives a most probable value of 19 ps(-1) and a range of 17 < delta m(s) < 21 ps(-1)at the 90% C.L., assuming Gaussian uncertainties. This is the first direct two-sided bound measured by a single experiment. If delta m(s) lies above 22 ps(-1), then the probability that it would produce a likelihood minimum similar to the one observed in the interval 16-22 ps(-1) is (5.0 +/- 0.3)%.  相似文献   

16.
研究了在表面活性剂存在下,锗与2,4二氯苯基荧光酮(2,4DClPF)的显色条件,在18~25mol·L-1硫酸介质中,锗与2,4DClPF、阳离子表面活性剂十六烷基三甲基溴化铵(CTMAB)形成有色三元胶束络合物,其最大吸收波长为516nm,表观摩尔吸光系数ε为138×105L·mol-1·cm-1。方法的线性范围为0~125μg·25mL-1,回收率为103%~106%,相对标准偏差为11%~17%。所拟方法用于煤样中微量锗的测定,结果较满意。  相似文献   

17.
该文建立了新的流动注射-化学发光快速测定莱克多巴胺的分析方法。基于碱性介质中莱克多巴胺对鲁米诺-铁氰化钾体系化学发光的增敏作用,研究了各因素对化学发光的影响。结果表明,在最佳发光条件下,相对发光强度与莱克多巴胺浓度在4.0×10-9~8.0×10-7 g.mL-1范围内呈良好的线性关系,检出限为2.5×10-9 g.mL-1,相对标准偏差为5.6%。应用该方法成功分析了猪肉和尿样中莱克多巴胺的含量,回收率为69.3%~101.3%,结果令人满意。  相似文献   

18.
应用双波长比值光谱法测定了复方乙酰水杨酸片中三组分的含量。依据复方乙酰水杨酸片中三组分的比值光谱特征, 选择213,227,245和265 nm作为测定三个组分的波长。结果显示乙酰水杨酸在5~20 μg·mL-1, 非那西丁在2~10 μg·mL-1, 咖啡因在2~20 μg·mL-1浓度范围内线性关系良好,平均回收率分别为100.03%,100.23%和99.96%。样品测定结果与部颁标准方法一致(P>0.05)。本法具有测定波长少、计算简单、光谱“分离”能力强以及能在低档分光光度计上实现, 易于推广等特点。  相似文献   

19.
核酸-桑色素-铝(Ⅲ)三元荧光体系的研究   总被引:5,自引:2,他引:3  
基于核酸对桑色素 铝 (Ⅲ )配合物的荧光增强作用 ,以桑色素 铝 (Ⅲ )为荧光探针 ,考察该探针与核酸的结合反应 ,建立了新的准确测定核酸的方法 ,并研究了该三元荧光体系的作用机理。在 pH 8 5时 ,fsDNA ,ctDNA ,smDNA和 yRNA的浓度与桑色素 铝 (Ⅲ )的荧光强度成线性关系 ,响应范围分别为 0 2 5~1 5 0 ,0 2 5~ 2 0 0 ,0 10~ 1 6 0和 0 2 5~ 2 0 0 μg·mL-1,检测限 (3σ/K)分别为 3,2 ,2和 3ng·mL-1。测定了合成样品 ,回收率 93 3%~ 10 7 9% ,相对标准偏差小于 3 6 %  相似文献   

20.
良性前列腺增生组织对钛宝石激光的吸收和散射特性   总被引:1,自引:1,他引:0  
研究了经尿道等离子体双极电切除术(PKRP)切除和经尿道前列腺电切术(TURP)切除的前列腺增生(BPH)组织对640, 660, 680, 700, 720, 740, 760, 780, 800, 820, 840, 860和880 nm波长的钛宝石激光的光学特性及其差异,实验采用双积分球测量系统以及反向倍增法获取BPH组织的吸收和散射特性参数。结果表明:PKRP和TURP切除的BPH组织对这13个不同波长的激光的吸收系数和约化散射系数都是随着激光波长增大而明显减小的,PKRP切除的BPH组织对这同一波长的激光的吸收系数和约化散射系数都明显较TURP切除的BPH组织对相应的波长的激光的吸收系数和约化散射系数要小,PKRP和TURP切除的BPH组织的吸收系数以及约化散射系数的最大值都在640 nm,其值分别为(0.885±0.022)和(0.955±0.024)mm-1以及(1.564±0.039)和(1.658±0.042)mm-1,其差异分别为7.91%以及6.01%,其最小值都在880 nm,其值分别为(0.443±0.011)和(0.455±0.011)mm-1以及(1.117±0.028)和(1.197±0.030)mm-1,其差异分别为2.71%以及7.16%。PKRP和TURP切除的BPH组织对660 nm的吸收系数的差异最大,其值为8.95%,其差异最小在860 nm,其值为1.75%,PKRP和TURP切除的BPH组织对800 nm的约化散射系数的差异最大,其值为9.13%,其差异最小在640 nm,其值为6.01%。  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号