首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
Extraction and determination of estrogens in water samples were performed using alcoholic-assisted dispersive liquid–liquid microextraction (AA-DLLME) and high-performance liquid chromatography (UV/Vis detection). A Plackett–Burman design and a central composite design were applied to evaluate the AA-DLLME procedure. The effect of six parameters on extraction efficiency was investigated. The factors studied were volume of extraction and dispersive solvents, extraction time, pH, amount of salt and agitation rate. According to Plackett–Burman design results, the effective parameters were volume of extraction solvent and pH. Next, a central composite design was applied to obtain optimal condition. The optimized conditions were obtained at 220 μL 1-octanol as extraction solvent, 700 μL ethanol as dispersive solvent, pH 6 and 200 μL sample volume. Linearity was observed in the range of 1–500 μg L?1 for E2 and 0.1–100 μg L?1 for E1. Limits of detection were 0.1 μg L?1 for E2 and 0.01 μg L?1 for E1. The enrichment factors and extraction recoveries were 42.2, 46.4 and 80.4, 86.7, respectively. The relative standard deviations for determination of estrogens in water were in the range of 3.9–7.2 % (n = 3). The developed method was successfully applied for the determination of estrogens in environmental water samples.  相似文献   

2.
3.
A simple ultrasound-assisted dispersive liquid–liquid microextraction method combined with liquid chromatography was developed for the preconcentration and determination of six pyrethroids in river water samples. The procedure was based on a ternary solvent system to formatting tiny droplets of extractant in sample solution by dissolving appropriate amounts of water-immiscible extractant (tetrachloromethane) in watermiscible dispersive solvent (acetone). Various parameters that affected the extraction efficiency (such as type and volume of extraction and dispersive solvent, extraction time, ultrasonic time, and centrifuging time) were evaluated. Under the optimum condition, good linearity was obtained in a range of 0.00059–1.52 mg L−1 for all analytes with the correlation coefficient (r2) > 0.999. Intra-assay and inter-assay precision evaluated as the relative standard deviation (RSD) were less than 3.4 and 8.9%. The recoveries of six pyrethroids at three spiked levels were in the range of 86.2–109.3% with RSD of less than 8.7%. The enrichment factors for the six pyrethroids were ranged from 767 to 1033 folds.  相似文献   

4.
An analytical method, solid-phase extraction combined with dispersive liquid–liquid microextration (SPE–DLLME), was established to determine polybrominated diphenyl ethers (PBDEs) in water and plant samples. After concentration and purification of the samples in LC-C18 column, 1.0-mL elution sample containing 22.0 μL 1,1,2,2-tetrachloroethane was injected rapidly into the 5.0-mL pure water. After extraction and centrifuging, the sedimented phase was injected rapidly into gas chromatography with electron-capture detection (GC–ECD). For water samples, enrichment factors (EFs) are in the range of 6838–9405 under the optimum conditions. The calibration curves are linear in the range of 0.1–100 ng L−1 (BDEs 28, 47) and 0.5–500 ng L−1 (BDEs 100, 99, 85, 154, 153). The relative standard deviations (RSDs) and the limits of detection (LODs) are in the range of 4.2–7.9% (n = 5) and 0.03–0.15 ng L−1, respectively. For plant samples, RSDs and LODs are in the range of 5.9–11.3% and 0.04–0.16 μg kg−1, respectively. The relative recoveries of well, river, sea, leachate, and clover samples, spiked with different levels of PBDEs, are 66.8–94.1%, 72.2–100.5%, 74.5–110.4%, 62.1–105.1%, 66.1–91.7%, 62.4–88.9%, and 64.5–83.2%, respectively. The results show that SPE–DLLME is a suitable method for the determination of PBDEs in water and plant samples.  相似文献   

5.
For the first time, the use of a magnetic stirrer within the syringe of an automated syringe pump and the resulting possible analytical applications are described. A simple instrumentation following roughly the one from sequential injection analyzer systems is used in combination with an adaptor, which is placed onto the barrel of a glass syringe. Swirling around the longitudinal axis of the syringe and holding two strong neodymium magnets, it causes a rotating magnetic field and serves as driver for a magnetic stirring bar placed inside of the syringe.  相似文献   

6.
Dispersive liquid–liquid microextraction (DLLME) has become a very popular environmentally benign sample-preparation technique, because it is fast, inexpensive, easy to operate with a high enrichment factor and consumes low volume of organic solvent. DLLME is a modified solvent extraction method in which acceptor-to-donor phase ratio is greatly reduced compared with other methods. In this review, in order to encourage further development of DLLME, its combination with different analytical techniques such as gas chromatography (GC), high-performance liquid chromatography (HPLC), inductively coupled plasma-optical emission spectrometry (ICP-OES) and electrothermal atomic absorption spectrometry (ET AAS) will be discussed. Also, its applications in conjunction with different extraction techniques such as solid-phase extraction (SPE), solidification of floating organic drop (SFO) and supercritical fluid extraction (SFE) are summarized. This review focuses on the extra steps in sample preparation for application of DLLME in different matrixes such as food, biological fluids and solid samples. Further, the recent developments in DLLME are presented. DLLME does have some limitations, which will also be discussed in detail. Finally, an outlook on the future of the technique will be given.  相似文献   

7.
Alkyl esters of p-hydroxybenzoic acid (parabens) are a family of compounds that have been in use since the 1920s as preservatives in cosmetic formulations, with one of the lowest rates of skin problems reported in dermatological patients. However, in the last few years, many scientific publications have demonstrated that parabens are weak endocrine disruptors, meaning that they can interfere with the function of endogenous hormones, increasing the risk of breast cancer. In the present work, a new sample treatment method is introduced based on dispersive liquid–liquid microextraction for the extraction of the most commonly used parabens (methyl-, ethyl-, propyl-, and butylparaben) from human serum samples followed by separation and quantification using ultrahigh performance liquid chromatography–tandem mass spectrometry. The method involves an enzymatic treatment to quantify the total content of parabens. The extraction parameters (solvent and disperser solvent, extractant and dispersant volume, pH of the sample, salt addition, and extraction time) were accurately optimized using multivariate optimization strategies. Ethylparaben ring 13C6-labeled was used as surrogate. Limits of quantification ranging from 0.2 to 0.7 ng mL?1 and an interday variability (evaluated as relative standard deviations) from 3.8 to 11.9 % were obtained. The method was validated using matrix-matched calibration standard and a spike recovery assay. Recovery rates for spiked samples ranged from 96 to 106 %, and a good linearity up to concentrations of 100 ng mL?1 was obtained. The method was satisfactorily applied for the determination of target compounds in human serum samples.  相似文献   

8.
A simple, rapid and efficient method, ionic liquid based dispersive liquid–liquid microextraction (IL-DLLME), has been developed for the first time for the determination of 18 polycyclic aromatic hydrocarbons (PAHs) in water samples. The chemical affinity between the ionic liquid (1-octyl-3-methylimidazolium hexafluorophosphate) and the analytes permits the extraction of the PAHs from the sample matrix also allowing their preconcentration. Thus, this technique combines extraction and concentration of the analytes into one step and avoids using toxic chlorinated solvents. The factors affecting the extraction efficiency, such as the type and volume of ionic liquid, type and volume of disperser solvent, extraction time, dispersion stage, centrifuging time and ionic strength, were optimised. Analysis of extracts was performed by high performance liquid chromatography (HPLC) coupled with fluorescence detection (Flu). The optimised method exhibited a good precision level with relative standard deviation values between 1.2% and 5.7%. Quantification limits obtained for all of these considered compounds (between 0.1 and 7 ng L−1) were well below the limits recommended in the EU. The extraction yields for the different compounds obtained by IL-DLLME, ranged from 90.3% to 103.8%. Furthermore, high enrichment factors (301–346) were also achieved. The extraction efficiency of the optimised method is compared with that achieved by liquid–liquid extraction. Finally, the proposed method was successfully applied to the analysis of PAHs in real water samples (tap, bottled, fountain, well, river, rainwater, treated and raw wastewater).  相似文献   

9.
This paper describes a dispersive liquid–liquid microextraction (DLLME) procedure using room temperature ionic liquids (RTILs) coupled to high-performance liquid chromatography with diode array detection capable of quantifying trace amounts of eight pesticides (i.e. thiophanate-methyl, carbofuran, carbaryl, tebuconazole, iprodione, oxyfluorfen, hexythiazox and fenazaquin) in bananas. Fruit samples were first homogenized and extracted (1 g) with acetonitrile and after suitable evaporation and reconstitution of the extract in 10 mL of water, a DLLME procedure using 1-hexyl-3-methylimidazolium hexafluorophosphate ([C6MIM][PF6]) as extraction solvent was used. Experimental conditions affecting the DLLME procedure (sample pH, sodium chloride percentage, ionic liquid amount and volume of disperser solvent) were optimized by means of an experimental design. In order to determine the presence of a matrix effect, calibration curves for standards and fortified banana extracts (matrix matched calibration) were studied. Mean recovery values of the extraction of the pesticides from banana samples were in the range of 69–97% (except for thiophanate-methyl and carbofuran, which were 53–63%) with a relative standard deviation lower than 8.7% in all cases. Limits of detection achieved (0.320–4.66 μg/kg) were below the harmonized maximum residue limits established by the European Union (EU). The proposed method, was also applied to the analysis of this group of pesticides in nine banana samples taken from the local markets of the Canary Islands (Spain). To the best of our knowledge, this is the first application of RTILs as extraction solvents for DLLME of pesticides from samples different than water.  相似文献   

10.
11.
A new chiral separation system effective for the enantioselective extraction of racemic trans-cyclohexane-1,2-diamine is presented. Enantioselective dispersive liquid–liquid microextraction has been used for the chiral microseparation of trans-cyclohexane-1,2-diamine, with a chiral azophenolic crown ether being identified as a versatile chiral selector. The influence of various process conditions on the extraction performance was studied experimentally. It was found that the operational selectivity in one extraction step is mainly related to the type and volume of the solvents, chiral selector concentration, extraction time, temperature of sample solution, and pH. At optimum conditions (300 μL of diethyl ether as the extraction solvent 1 mL of methanol as the disperser solvent, with 5 mmol L?1 chiral selector concentration, pH of the sample equal to 4.5, 30 min extraction time and a temperature of 10 °C), the distribution ratio of (R,R)- and (S,S)-trans-cyclohexane-1,2-diamine was 18.3 and 1.8, respectively, while the enantioselectivity value of 10.2 was found at the optimum condition.  相似文献   

12.
A novel approach for the determination of seven fungicides (metalaxyl-M, penconazole, folpet, diniconazole, propiconazole, difenoconazole and azoxystrobin) in wine samples is presented. Analytes were extracted from the matrix and transferred to a small volume of a high density, water insoluble solvent using solid-phase extraction (SPE) followed by dispersive liquid–liquid microextraction (DLLME). Variables affecting the performance of both steps were thoroughly investigated (metalaxyl-M was not included in some optimisation studies) and their effects on the selectivity and efficiency of the whole sample preparation process are discussed. Under optimised conditions, 20 mL of wine were first concentrated using a reversed-phase sorbent and then target compounds were eluted with 1 mL of acetone. This extract was mixed with 0.1 mL of 1,1,1-trichloroethane (CH3CCl3) and the blend added to 10 mL of ultrapure water. After centrifugation, an aliquot (1–2 μL) of the settled organic phase was analyzed by gas chromatography (GC) with electron capture (ECD) and mass spectrometry (MS) detection. The method provided enrichment factors (EFs) around 200 times and an improved selectivity in comparison to use of SPE as single sample preparation technique. Moreover, the yield of the global process was similar for red and white wine samples and the achieved limits of quantification (LOQs) (from 30 to 120 ng L−1 and from 40 to 250 ng L−1, for GC–ECD and GC–MS, respectively) were low enough for the determination of target species in commercial wines. Among compounds considered in this work, metalaxyl-M and azoxystrobin were found in several wines at concentrations from 0.8 to 32 ng mL−1.  相似文献   

13.
Dispersive liquid–liquid microextraction (DLLME) high-performance liquid chromatography (HPLC) was developed for extraction and determination of triazines from honey. A room temperature ionic liquid, 1-hexyl-3-methylimidazolium hexafluorophosphate [C6MIM][PF6.], was used as extraction solvent and Triton X 114 was used as dispersant. A mixture of 175 μL [C6MIM][PF6] and 50 μL 10% Triton X 114 was rapidly injected into the 20 mL honey sample by syringe. After extraction, phase separation was performed by centrifugation and the sedimented phase was analyzed by HPLC. Some experimental parameters, such as type and volume of extraction solvent, concentration of dispersant, pH value of sample solution, salt concentration and extraction time were investigated and optimized. The detection limits for chlortoluron, prometon, propazine, linuron and prebane are 6.92, 5.84, 8.55, 8.59 and 5.31 μg kg−1, respectively. The main advantages of the proposed method are simplicity of operation, low cost, high enrichment factor and extraction solvent volume at microliter level. Honey samples were analyzed by the proposed method and obtained results indicated that the proposed method provides acceptable recoveries and precisions.  相似文献   

14.
Favipiravir is a potential antiviral medication that has been recently licensed for Covid-19 treatment. In this work, a gadolinium-based magnetic ionic liquid was prepared and used as an extractant in dispersive liquid–liquid microextraction (DLLME) of favipiravir in human plasma. The high enriching ability of DLLME allowed the determination of favipiravir in real samples using HPLC/UV with sufficient sensitivity. The effects of several variables on extraction efficiency were investigated, including type of extractant, amount of extractant, type of disperser and disperser volume. The maximum enrichment was attained using 50 mg of the Gd-magnetic ionic liquid (MIL) and 150 μl of tetrahydrofuran. The Gd-based MIL could form a supramolecular assembly in the presence of tetrahydrofuran, which enhanced the extraction efficiency of favipiravir. The developed method was validated according to US Food and Drug Administration bioanalytical method validation guidelines. The coefficient of determination was 0.9999, for a linear concentration range of 25 to 1.0 × 105 ng/ml. The percentage recovery (accuracy) varied from 99.83 to 104.2%, with RSD values (precision) ranging from 4.07 to 11.84%. The total extraction time was about 12 min and the HPLC analysis time was 5 min. The method was simple, selective and sensitive for the determination of favipiravir in real human plasma.  相似文献   

15.
Recently, increasing interest on the use of dispersive liquid–liquid microextraction (DLLME) developed in 2006 by Rezaee has been found in the field of separation science. DLLME is miniaturized format of liquid–liquid extraction in which acceptor-to-donor phase ratio is greatly reduced compared with other methods. In the present review, the combination of DLLME with different analytical techniques such as atomic absorption spectrometry (AAS), inductively coupled plasma-optical emission spectrometry (ICP-OES), gas chromatography (GC), and high-performance liquid chromatography (HPLC) for preconcentration and determination of inorganic analytes in different types of samples will be discussed. Recent developments in DLLME, e.g., displacement-DLLME, the use of an auxiliary solvent for adjustment of density of extraction mixture, and the application of ionic liquid-based DLLME in determination of inorganic species even in the presence of high content of salts are presented in the present review. Finally, comparison of DLLME with the other liquid-phase microextraction approaches and limitations of this technique are provided.  相似文献   

16.
A dispersive liquid–liquid microextraction (DLLME) method followed by high-performance liquid chromatography–triple quadrupole mass spectrometry has been developed for the simultaneous determination of linear alkylbenzene sulfonates (LAS C10, C11, C12, and C13), nonylphenol (NP), nonylphenol mono- and diethoxylates (NP1EO and NP2EO), and di-(2-ethylhexyl)phthalate (DEHP). The applicability of the method has been tested by the determination of the above mentioned organic pollutants in tap water and wastewater. Several parameters affecting DLLME, such as, the type and volume of the extraction and disperser solvents, sample pH, ionic strength and number of extractions, have been evaluated. Methanol (1.5 mL) was selected among the six disperser solvent tested. Dichlorobenzene (50 μL) was selected among the four extraction solvent tested. Enrichment factor achieved was 80. Linear ranges in samples were 0.01–3.42 μg L−1 for LAS C1013 and NP2EO, 0.09–5.17 μg L−1 for NP1EO, 0.17–9.19 μg L−1 for NP and 0.40–17.9 μg L−1 for DEHP. Coefficients of correlation were higher than 0.997. Limits of quantitation in tap water and wastewater were in the ranges 0.009–0.019 μg L−1 for LAS, 0.009–0.091 μg L−1 for NP, NP1EO and NP2EO and 0.201–0.224 μg L−1 for DEHP. Extraction recoveries were in the range from 57 to 80%, except for LAS C10 (30–36%). The method was successfully applied to the determination of these pollutants in tap water and effluent wastewater from Seville (South of Spain). The DLLME method developed is fast, easy to perform, requires low solvent volumes and allows the determination of the priority hazardous substances NP and DEHP (Directive 2008/105/EC).  相似文献   

17.
A sensitive, simple, and rapid method is developed for ion-pair-based surfactant-assisted dispersive liquid–liquid microextraction (IPSA-DLLME) and flame atomic absorption spectrometric determination of cadmium in water samples. In this procedure, trace amounts of Cd2+ were converted to CdI 4 2– , and after addition of a tetrabutylammonium bromide (TBAB) solution as cationic surfactant the analyte was transformed to the ion-pair state. This cadmium species was extracted by fast injection of a solution containing 200 μL of chloroform and 800 μL of methanol as extraction and disperser solvents, respectively. The pH of the sample solution, concentration of iodide, TBAB amount, and the extractant volume were optimized using a 27-run Box–Behnken design with a triplicate central point. Under the optimized conditions, the calibration curve was linear in the range 1–200 μg L–1 (R 2 = 0.9959); with the detection limit (signal/noise = 3) of 0.28 μg L–1. The relative standard deviations (RSD) for eight runs (Cd2+ = 10 μg L–1) and enrichment factor were found to be 3.04 % and 50, respectively.  相似文献   

18.
A simple and cost effective sample pre-treatment method, dispersive liquid–liquid microextraction (DLLME), has been developed for the extraction of six fluoroquinolones (FQs) from chicken liver samples. Clean DLLME extracts were analyzed for fluoroquinolones using liquid chromatography with diode array detection (LC-DAD). Parameters such as type and volume of disperser solvent, type and volume of extraction solvent, concentration and composition of phosphoric acid in the disperser solvent and pH were optimized. Linearity in the concentration range of 30–500 μg kg−1 was obtained with regression coefficients ranging from 0.9945 to 0.9974. Intra-day repeatability expressed as % RSD was between 4 and 7%. The recoveries determined in spiked blank chicken livers at three concentration levels (i.e. 50, 100 and 300 μg kg−1) ranged from 83 to 102%. LODs were between 5 and 19 μg kg−1 while LOQs ranged between 23 and 62 μg kg−1. All of the eight chicken liver samples obtained from the local supermarkets were found to contain at least one type of fluoroquinolone with enrofloxacin being the most commonly detected. Only one sample had four fluoroquinolone antibiotics (ciprofloxacin, difloxacin, enrofloxacin, norfloxacin). Norfloxacin which is unlicensed for use in South Africa was also detected in three of the eight chicken liver samples analyzed. The concentration levels of all FQs antibiotics in eight samples ranged from 8.8 to 35.3 μg kg−1, values which are lower than the South African stipulated maximum residue limits (MRL).  相似文献   

19.
A new micro-extraction technique named low-density magnetofluid dispersive liquid–liquid microextraction (LMF-DMMLE) has been developed, which permits a wider range of solvents and can be combined with various detection methods. Comparing with the existing low density solvents micro-extraction methods, no special devices and complicated operations were required during the whole extraction process. Dispersion of the low-density magnetofluid into the aqueous sample is achieved by using vortex mixing, so disperser solvent was unnecessary. The extraction solvent was collected conveniently with an external magnetic field placed outside the extraction container after dispersing. Then, the magnetic nanoparticles were easily removed by adding precipitation reagent under the magnetic field. In order to evaluate the validity of this method, ten organochlorine pesticides (OCPs) were chosen as the analytes. Parameters influencing the extraction efficiency such as extraction solvents, volume of extraction solvents, extraction time, and ionic strength were investigated and optimized. Under the optimized conditions, this method showed high extraction efficiency with low limits of detection of 1.8–8.4 ng L−1, good linearity in the range of 0.05–10.00 μg L−1 and the precisions were in the range of 1.3–9.6% (RSD, n = 5). Finally, this method was successfully applied in the determination of OCPs in real water samples.  相似文献   

20.
A rapid and novel method combining dispersive liquid–liquid microextraction and high-performance liquid chromatography coupled with fluorescence detection was developed for the determination of donepezil in human urine. Parameters affecting extraction efficiency and chromatographic determination, such as the type and volume of the extraction and disperser solvent, pH of sample for dispersive liquid–liquid microextraction, mobile-phase composition, pH, column oven temperature, and flow rate for chromatographic determination, were evaluated and optimized. Using a C18 core–shell column (7.5 × 4.6?mm, 2.7?μm), the determination of donepezil was accomplished within 5?min. Under optimum conditions, developed method was linear in the range of 0.5–25?ng?mL?1 with the correlation coefficient >0.99. Limit of detection was 0.15?ng?mL?1. The relative standard deviation at three concentration levels (2, 12.5, and 20?ng?mL?1) was less than 11% with accuracy in the range of 96.9–102.8%. The results of this study demonstrate that the use of dispersive liquid–liquid microextraction and core–shell column can be considered as a powerful tool for the analysis of donepezil in human urine.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号