首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
In the present work, acidic and basic drugs were simultaneously extracted by a novel method of high efficiency herein referred to as two-step voltage dual electromembrane extraction (TSV-DEME). Optimizing effective parameters such as composition of organic liquid membrane, pH values of donor and acceptor solutions, voltage and duration of each step, the method had its figures of merit investigated in pure water, human plasma, wastewater, and breast milk samples. Simultaneous extraction of acidic and basic drugs was done by applying potentials of 150 V and 400 V for 6 min and 19 min as the first and second steps, respectively. The model compounds were extracted from 4 mL of sample solution (pH = 6) into 20 μL of each acceptor solution (32 mM NaOH for acidic drugs and 32 mM HCL for basic drugs). 1-Octanol was immobilized within the pores of a porous hollow fiber of polypropylene, as the supported liquid membrane (SLM) for acidic drugs, and 2-ethyle hexanol, as the SLM for basic drugs. The proposed TSV-DEME technique provided good linearity with the resulting correlation coefficients ranging from 0.993 to 0.998 over a concentration range of 1–1000 ng mL−1. The limit of detections of the drugs were found to range within 0.3–1.5 ng mL−1, while the corresponding repeatability ranged from 7.7 to 15.5% (n = 4). The proposed method was further compared to simple dual electromembrane extraction (DEME), indicating significantly higher recoveries for TSV-DEME procedure (38.1–68%), as compared to those of simple DEME procedure (17.7–46%). Finally, the optimized TSV-DEME was applied to extract and quantify model compounds in breast milk, wastewater, and plasma samples.  相似文献   

2.
Recent advances in electromembrane extraction (EME) methodology calls for effective and accessible detection methods. Using imipramine and clomipramine as model therapeutics, this proof-of-principle work combines EME with gas chromatography analysis employing a flame ionization detector (FID). The drugs were extracted from acidic aqueous sample solutions, through a supported liquid membrane (SLM) consisting of 2-nitrophenyl octyl ether (NPOE) impregnated on the walls of the hollow fiber. EME parameters, such as SLM composition, type of ion carrier, pH and the composition of donor and acceptor solutions, agitation speed, extraction voltage, and extraction time were studied in detail. Under optimized conditions, the therapeutics were effectively extracted from different matrices with recoveries ranging from 90 to 95%. The samples were preconcentrated 270–280 times prior to GC analysis. Reliable linearity was also achieved for calibration curves with a regression coefficient of at least 0.995. Detection limits and intra-day precision (n = 3) were less than 0.7 ng mL−1 and 8.5%, respectively. Finally, method was applied to determination and quantification of drugs in human plasma and urine samples and satisfactory results were achieved.  相似文献   

3.
A totally new concept based on electrokinetic migration was evaluated for the extraction of three biologically active peptides from human plasma. Angiotensin 2, leu-enkephalin, and endomorphin 1 migrated from a diluted human plasma sample (2 mL, positive electrode), through a supported liquid membrane (SLM) of 1-octanol, di-isobutylketon, and di-(2-ethylhexyl) phosphate (DEHP) (55:35:10, w/w/w), and into an acidified acceptor solution (25 μL 50 mM HCl, negative electrode) by the application of an electrical potential (20 V) across the SLM. After only five min of extraction, the acceptor solution was injected and analyzed directly by liquid chromatography. The three peptides were quantified by tandem mass spectrometry, with acceptable linearity ranging from 100.0 to 1000.0 pg mL−1 (r2 in the range 0.9736–0.9988), and repeatability (RSD) ranging between 15% and 24% (n = 5), using plasma spiked with the three peptides in 100 pg mL−1 concentration. The estimated detection limits (S/N ratio of 3:1) for angiotensin 2, leu-enkephalin, and endomorphin 1, were 60, 24, and 24 pg mL−1, respectively. With this novel approach based on electromembrane extraction (EME) coupled to LC–MS/MS, endogenous concentrations of the peptides were detected in non-spiked human plasma samples, with a total analysis time less than 50 min. These experimental findings were highly interesting, and showed the opportunities for EME with regard to future peptide extractions.  相似文献   

4.
A simple and sensitive single step electro membrane extraction (EME) procedure was demonstrated for biological organic anions with determination by ion chromatography (IC). Nitrite, adipate, oxalate, iodide, fumarate, thiocyanate and perchlorate were extracted from aqueous donor solutions, across a supported liquid membrane (SLM) consisting of methanol impregnated in the walls of a porous polypropylene membrane bag and into an alkaline aqueous acceptor solution in the lumen of the propylene envelope by the application of potential of 12 V applied across the SLM. The acceptor solution was analyzed by IC. Parameters affecting the extraction performance such as type of SLM, extraction time, pH of the donor and acceptor solution, and extraction voltage were studied. The most favorable EME conditions were methanol as the SLM, extraction time of 5 min, pH of acceptor and sample solutions of 12 and 4, respectively, and a voltage of 12 V. Portable 12 V batteries were used in the study. Under these optimized conditions, all anions had enrichment factors ranging from 3.6 to 36.2 with relative standard deviations (n = 3) of between 6.6 and 17.5%. Good linearity ranging from 0.1 to 10 μg mL−1 with coefficients of correlation (r) of between 0.9981 and 0.9996 were obtained. The limits of detection of the EME-IC method were from 0.01 to 0.14 μg mL−1. The developed methodology was applied to amniotic fluid samples to evaluate the feasibility of the method for real applications.  相似文献   

5.
Three-phase solvent bar microextraction (TPSBME) technique is described for the quantitative determination of trace amounts of clenbuterol (CB) in urine samples using liquid chromatography (LC) and electrospray tandem mass spectrometry (ES-TMS). CB was extracted from a basified urine sample (donor phase) into the organic solvent residing in the pores of a freely moving hollow fiber and then back extracted into an acidic solution (acceptor phase) inside the lumen of the hollow fiber. The ends of the fiber were pressure-sealed. Here, forward and back extraction took place spontaneously. We studied various parameters affecting the extraction efficiency viz. type of organic solvent (octanol, nonanol and dihexyl ether) used for immobilization in the pores of the hollow fiber, i.e. extraction time (10-40 min), stirring speed (0-1000 rpm), effect of sodium chloride (0-25%, w/v) and concentration of the donor (0.25-3 M NaOH) and the acceptor (0.5-5 M formic acid) phases. After extraction, CB was analyzed by injecting the analyte enriched acceptor phase into LC combined with ES-TMS. Enrichment factor (79), repeatability (R.S.D. = 5.1%), correlation coefficient (0.9972, for the range of 0.1-4 ng mL−1), detection limit (7 pg mL−1) were also investigated. The present technique is compared with the reported solid phase microextraction techniques in terms of selectivity, analysis time per extraction, cost of analysis per extraction, and precision. Among all microextraction techniques reported, this technique is the most economical sample preparation/preconcentration technique to our knowledge. The method was applied for the analysis of CB in human urine.  相似文献   

6.
A novel method for the selective electromembrane extraction (EME) of U6+ prior to fluorometric determination has been proposed. The effect of extraction conditions including supported liquid membrane (SLM) composition, extraction time and extraction voltage were investigated. An SLM composition of 1% di-2-ethyl hexyl phosphonic acid in nitrophenyl octyl ether (NPOE) showed good selectivity, recovery and enrichment factor. The best performance was achieved at an extraction potential of 80 volts and an extraction time of 14 minutes Under the optimized conditions, a linear range from 1 to 1000 ng mL−1 and LOD of 0.1 ng mL−1 were obtained for the determination of U6+. The EME method showed good performance in sample cleanup and the reduction of the interfering effects of Mn2+, Zn2+, Cd2+, Ni2+, Fe3+, Co2+, Cu2+, Cl and PO43− ions during fluorometric determination of uranium in real water samples. The recoveries above 54% and enrichment factors above 64.7 were obtained by the proposed method for real sample analysis.  相似文献   

7.
A simple, selective, sensitive and inexpensive method of hollow fiber-based liquid–liquid–liquid microextraction (HF-LLLME) combined with high performance liquid chromatography (HPLC)-ultraviolet (UV) detection was developed for the determination of four acidic phytohormones (salicylic acid (SA), indole-3-acetic acid (IAA), (±) abscisic acid (ABA) and (±) jasmonic acid (JA)) in natural coconut juice. To the best of our knowledge, this is the first report on the use of liquid phase microextraction (LPME) as a sample pretreatment technique for the simultaneous analysis of several phytohormones. Using phenetole to fill the pores of hollow fiber as the organic phase, 0.1 mol L−1 NaOH solution in the lumen of hollow fiber as the acceptor phase and 1 mol L−1 HCl as the donor phase, a simultaneous preconcentration of four target phytohormones was realized. The acceptor phase was finally withdrawn into the microsyringe and directly injected into HPLC for the separation and quantification of the target phytohormones. The factors affecting the extraction efficiency of four phytohormones by HF-LLLME were optimized with orthogonal design experiment, and the data was analyzed by Statistical Product and Service Solutions (SPSS) software. Under the optimized conditions, the enrichment factors for SA, IAA, ABA and JA were 243, 215, 52 and 48, with the detection limits (S/N = 3) of 4.6, 1.3, 0.9 ng mL−1 and 8.8 μg mL−1, respectively. The relative standard deviations (RSDs, n = 7) were 7.9, 4.9, 6.8% at 50 ng mL−1 level for SA, IAA, ABA and 8.4% at 500 μg mL−1 for JA, respectively. To evaluate the accuracy of the method, the developed method was applied for the simultaneous analysis of several phytohormones in five natural coconut juice samples, and the recoveries for the spiked samples were in the range of 88.3–119.1%.  相似文献   

8.
In this paper a novel solid phase extraction method to determine Co(II) and Ni(II) using silica gel-polyethylene glycol (Silica-PEG) as a new adsorbent is described. The method is based on the adsorption of cobalt and nickel ions in alkaline media on polyethylene glycol-silica gel in a mini-column, elution with nitric acid and determination by flame atomic absorption spectrometry. The adsorption conditions such as NaOH concentration, sample volume and amount of adsorbent were optimized in order to achieve highest sensitivity. The calibration graph was linear in the range of 0.5-200.0 ng mL−1 for Co(II) and 2.0-100.0 ng mL−1 for Ni(II) in the initial solution. The limit of detection based on 3Sb was 0.37 ng mL−1 for Co(II) and 0.71 ng mL−1 for Ni(II). The relative standard deviations (R.S.D.) for ten replicate measurements of 40 ng mL−1 of Co(II), and Ni(II) were 3.24 and 3.13%, respectively. The method was applied to determine Co(II) and Ni(II) in black tea, rice flour, sesame seeds, tap water and river water samples.  相似文献   

9.
A rapid and sensitive method for the determination of carbendazim (methyl benzimidazole-2-ylcarbamate, MBC) and thiabendazole (TBZ) in water and soil samples was developed by using dispersive liquid-liquid microextraction (DLLME) coupled with high performance liquid chromatography with fluorescence detection. The water samples were directly used for the DLLME extraction. For soil samples, the target analytes were first extracted by 0.1 mol L−1 HCl. Then, the pH of the extract was adjusted to 7.0 with 2 mol L−1 NaOH before the DLLME extraction. In the DLLME extraction method, chloroform (CHCl3) was used as extraction solvent and tetrahydrofuran (THF) as dispersive solvent. Under the optimum conditions, the enrichment factors for MBC and TBZ were ranged between 149 and 210, and the extraction recoveries were between 50.8 and 70.9%, respectively. The linearity of the method was obtained in the range of 5-800 ng mL−1 for water sample analysis, and 10-1000 ng g−1 for soil samples, respectively. The correlation coefficients (r) ranged from 0.9987 to 0.9997. The limits of detection were 0.5-1.0 ng mL−1 for water samples, and 1.0-1.6 ng g−1 for soil samples. The relative standard deviations (RSDs) varied from 3.5 to 6.8% (n = 5). The recoveries of the method for MBC and TBZ from water samples at spiking levels of 5 and 20 ng mL−1 were 84.0-94.0% and 86.0-92.5%, respectively. The recoveries for soil samples at spiking levels of 10 and 100 ng g−1 varied between 82.0 and 93.4%.  相似文献   

10.
Liquid-phase microextraction (LPME) based on polypropylene hollow fibers was evaluated for the extraction of the post-harvest fungicides thiabendazole (TBZ), carbendazim (CBZ) and imazalil (IMZ) from orange juices. Direct LPME was performed without any sample pretreatment prior to the extraction, using a simple home-built equipment. A volume of 500 μL of 840 mM NaOH was added to 3 mL of orange juice in order to compensate the acidity of the samples and to adjust pH into the alkaline region. Analytes were extracted in their neutral state through a supported liquid membrane (SLM) of 2-octanone into 20 μL of a stagnant aqueous solution of 10 mM HCl inside the lumen of the hollow fiber. Subsequently, the acceptor solution was directly subjected to analysis. Capillary electrophoresis (CE) was used during the optimization of the extraction procedure. Working under the optimized extraction conditions, LPME effectively extracted the analytes from different orange juices, regardless of different pH or solid material (pulp) present in the sample, with recoveries that ranged between 17.0 and 33.7%. The analytical performance of the method was evaluated by liquid chromatography coupled with mass spectrometry (LC/MS). This technique provided better sensitivity than CE and permitted the detection below the μg L−1 level. The relative standard deviations of the recoveries (RSDs) ranged between 3.4 and 10.6%, which are acceptable values for a manual microextraction technique without any previous sample treatment, using a home-built equipment and working under non-equilibrium conditions (30 min extraction). Linearity was obtained in the range 0.1–10.0 μg L−1, with r = 0.999 and 0.998 for TBZ and IMZ, respectively. Limits of detection were below 0.1 μg L−1 and are consistent with the maximum residue levels permitted for pesticides in drinking water, which is the most restrictive regulation applicable for these kinds of samples. It has been demonstrated the suitability of three-phase LPME for the extraction of pesticides from citrus juices, suppressing any pretreatment step such as filtration or removal of the solid material from the sample, that may potentially involve a loss of analyte.  相似文献   

11.
A three-phase liquid-phase microextraction (LPME) method using porous polypropylene hollow fibre membrane with a sealed end was developed for the extraction of mirtazapine (MRT) and its two major metabolites, 8-hydroxymirtazapine (8-OHM) and demethylmirtazapine (DMR), from human plasma. The analytes were extracted from 1.0 mL of plasma, previously diluted and alkalinized with 3.0 mL 0.5 mol L−1 pH 8 phosphate buffer solution and supplemented with 15% sodium chloride (NaCl), using n-hexyl ether as organic solvent and 0.01 moL L−1 acetic acid solution as the acceptor phase. Haloperidol was used as internal standard. The chromatographic analyses were carried out on a chiral column, using acetonitrile-methanol-ethanol (98:1:1, v/v/v) plus 0.2% diethylamine as mobile phase, at a flow rate of 1.0 mL min−1. Multi-reaction monitoring (MRM) detection was performed by mass spectrometry (MS-MS) using a triple-stage quadrupole and electrospray ionization interface operating in the positive ion mode. The mean recoveries were in 18.3-45.5% range with linear responses over the 1.25-125 ng mL−1 concentration range for all enantiomers evaluated. The quantification limit (LOQ) was 1.25 ng mL−1. Within-day and between-day assay precision and accuracy (2.5, 50 and 100 ng mL−1) showed relative standard deviation and the relative error lower than 11.9% for all enantiomers evaluated. Finally, the method was successfully used for the determination of mirtazapine and its metabolite enantiomers in plasma samples obtained after single drug administration of mirtazapine to a healthy volunteer.  相似文献   

12.
A novel microextraction technique, air-assisted liquid–liquid microextraction (AALLME), which is a new version of dispersive liquid–liquid microextraction (DLLME) method has been developed for extraction and preconcentration of phthalate esters, dimethyl phthalate (DMP), diethyl phthalate (DEP), di-iso-butyl phthalate (DIBP), di-n-butyl phthalate (DNBP), and di-2-ethylhexyl phthalate (DEHP), from aqueous samples prior to gas chromatography–flame ionization detection (GC–FID) analysis. In this method, much less volume of an organic solvent is used as extraction solvent in the absence of a disperser solvent. Fine organic droplets were formed by sucking and injecting of the mixture of aqueous sample solution and extraction solvent with a syringe for several times in a conical test tube. After extraction, phase separation was performed by centrifugation and the enriched analytes in the sedimented phase were determined by GC–FID. Under the optimum extraction conditions, the method showed low limits of detection and quantification between 0.12–1.15 and 0.85–4 ng mL−1, respectively. Enrichment factors (EFs) and extraction recoveries (ERs) were in the ranges of 889–1022 and 89–102%, respectively. The relative standard deviations (RSDs) for the extraction of 100 ng mL−1 and 500 ng mL−1 of each phthalate ester were less than 4% for intra-day (n = 6) and inter-days (n = 4) precision. Finally some aqueous samples were successfully analyzed using the proposed method and three analytes, DIBP, DNBP and DEHP, were determined in them at ng mL−1 level.  相似文献   

13.
In this paper, an electromembrane extraction (EME) combined with a HPLC procedure using diode array (DAD) and fluorescence detection (FLD) has been developed for the determination of six widely used non-steroidal anti-inflammatory drugs (NSAIDs): salicylic acid (SAC), ketorolac (KTR), ketoprofen (KTP), naproxen (NAX), diclofenac (DIC) and ibuprofen (IBU). The drugs were extracted from basic aqueous sample solutions, through a supported liquid membrane (SLM) consisting of 1-octanol impregnated in the walls of a S6/2 Accurel® polypropylene hollow fiber, and into a basic aqueous acceptor solution resent inside the lumen of the hollow fiber with a potential difference of 10 V applied over the SLM. Extractions that were carried out in 10 min using a potential of 10 V from pH 12 NaOH aqueous solutions shown concentration enrichments factors of 28-49 in a pH 12 NaOH aqueous acceptor solution. The proposed method was successfully applied to urban wastewaters. Excellent selectivity was demonstrated as no interfering peaks were detected. The procedure allows very low detection and quantitation limits of 0.0009-9.0 and 0.003-11.1 μg L−1, respectively.  相似文献   

14.
Determination of estrogens in water by HPLC-UV using cloud point extraction   总被引:1,自引:0,他引:1  
Wang L  Cai YQ  He B  Yuan CG  Shen DZ  Shao J  Jiang GB 《Talanta》2006,70(1):47-51
A method based on cloud point extraction was developed to determine four kinds of estrogens: estriol (E3), estradiol (E2), estrone (E1), and progesterone (P) in water by high performance liquid chromatography separation and ultraviolet detection (HPLC-UV). The non-ionic surfactant Triton X-114 was chosen as extractant solvent. The parameters affecting extraction efficiency, such as concentrations of Triton X-114 and Na2SO4, equilibration temperature, equilibration time and centrifugation time were evaluated and optimized. Under the optimum conditions, preconcentration factors of 99 for E3, 73 for E2, 152 for E1 and 86 for P were obtained for 10 mL water sample. The detection of limitation was 0.23 ng mL−1 for E3, 0.32 ng mL−1 for E2, 0.25 ng mL−1 for E1 and 5.0 ng mL−1 for P. The proposed method was successfully applied to the determination of trace amount of estrogens in wastewater treatment plant (WWTP) effluent water and exposure water with 10 ng mL−1 E2 for toxicological study in our lab. For the case of WWTP effluent water samples, no estrogen was found. The accuracy of the proposed method was tested by recovery measurements of spiked samples and good recoveries of 81.2-99.5% were obtained.  相似文献   

15.
A three-phase hollow fiber liquid-phase microextraction (HF-LPME) coupled either with capillary electrophoresis (CE) or high performance liquid chromatography (HPLC) with UV detection methods was successfully developed for the determination of trace levels of the anti-diabetic drug, rosiglitazone (ROSI) in biological fluids. The analyte was extracted into dihexyl ether that was immobilized in the wall pores of a porous hollow fiber from 10 mL of aqueous sample, pH 9.5 (donor phase), and was back extracted into the acceptor phase that contained 0.1 M HCl located in the lumen of the hollow fiber. Parameters affecting the extraction process such as type of extraction solvent, HCl concentration, donor phase pH, extraction time, stirring speed, and salt addition were studied and optimized. Under the optimized conditions (extraction solvent, dihexyl ether; donor phase pH, 9.5; acceptor phase, 0.1 M HCl; stirring speed, 600 rpm; extraction time, 30 min; without addition of salt), enrichment factor of 280 was obtained. Good linearity and correlation coefficients of the analyte was obtained over the concentration ranges of 1.0–500 and 5.0–500 ng mL−1 for the HPLC (r2 = 0.9988) and CE (r2 = 0.9967) methods, respectively. The limits of detection (LOD) and limits of quantitation (LOQ) for the HPLC and CE methods were (0.18, 2.83) and (0.56, 5.00) ng mL−1, respectively. The percent relative standard deviation (n = 6) for the extraction and determination of three concentration levels (10, 250, 500 ng mL−1) of ROSI using the HPLC and CE methods were less than 10.9% and 13.2%, respectively. The developed methods are simple, rapid, sensitive and are suitable for the determination of trace amounts of ROSI in biological fluids.  相似文献   

16.
A simple and rapid method based on solid-phase micro extraction (SPME) technique followed by gas chromatography-mass spectrometry with selected ion monitoring (GC-MS, SIM) was developed by the simultaneous determination of 16 pesticides of seven different chemical groups [Six organophosphorus (trichlorfon, diazinon, methyl parathion, malathion, fenthion and ethyon), three pyrethroids (bifenhin, permethrin, cypermethrin), two imidazoles (imazalil and prochloraz), two strobilurins (azoxystrobin and pyraclostrobin), one carbamate (carbofuran), one tetrazine (clofentezine), and one triazole (difenoconazole)] in water. The pesticides extraction was done with direct immersion mode (DI-SPME) of the polyacrilate fiber (PA 85 µm). The extraction temperature was adjusted to 50 °C during 30 min, while stirring at 250 rpm was applied. After extraction, the fiber was introduced in the GC injector for thermal desorption for 5 min. at 280 °C. The method was validated using ultra pure water samples fortified with pesticides at different concentration levels and shows good linearity in the concentrations between 0.05 and 250.00 ng mL− 1. The LOD and LOQ ranged, from 0.02 to 0.30 ng mL− 1 and 0.05 to 1.00 ng mL− 1, respectively. Intra-day and inter-day precisions were determined in two concentration levels (5.00 and 50.00 ng mL− 1). Intra-day relative standard deviation (%R.S.D.) ranged between 3.6 and 13.6%, and inter-day (%R.S.D.) ranged between 6.3 and 18.5%. Relative recovery tests were carried out spiking the ultra pure sample with standards in three different concentration levels 0.20, 5.00 and 50.00 ng mL− 1. The recovery at 0.20 ng mL− 1 level varied from 86.4 ± 9.4% to 108.5 ± 10.5%, at 5.00 ng mL− 1 level varied from 77.5 ± 10.8% to 104.6 ± 9.6% and at 50.00 ng mL− 1 level varied from 70.2 ± 4.6% to 98.4 ± 8.5%. The proposed SPME method was applied in twenty-six water samples collected in the “Platô de Neópolis”, State of Sergipe, Brazil. Methyl parathion was detected in five samples with an average concentration of 0.17 ng mL− 1 and bifenthrin, pyraclostrobin and azoxystrobin residues were found in three samples with average concentrations of 2.28, 3.12 and 0.15 ng mL− 1, respectively.  相似文献   

17.
Amitriptyline, citalopram, fluoxetine, and fluvoxamine were isolated by electro membrane extraction (EME) from 70 μl of untreated plasma (pH 7.4), through a supported liquid membrane (SLM) of 1-ethyl-2-nitrobenzene immobilized in the pores of a porous polypropylene hollow fiber, and into 30 μl of 10 mM HCOOH as acceptor solution inside the lumen of the hollow fiber. The driving force of the extraction was a 9 V potential sustained over the SLM with a common battery, with the positive electrode placed in the plasma sample and the negative electrode placed in the acceptor solution. Extractions were performed under totally stagnant conditions with a very simple device for 1 min (kinetic regime), and subsequently the acceptor solution was analyzed directly by liquid chromatography–mass spectrometry (LC–MS). Recoveries were 12, 13, 22, and 17% for fluoxetine, amitriptyline, citalopram, and fluvoxamine, respectively. Sample clean-up was comparable to reversed-phase solid-phase extraction (SPE), but EME required substantially less time than SPE. The time advantage of EME was further improved by parallel extraction of three samples (for 1 min) with the same 9 V battery. EME from plasma combined with LC–MS provided limits of quantification (S/N = 10) in the range 0.4–2.3 ng/ml, linearity in the range 1–1000 ng/ml with r2-values of 0.998–0.999, and repeatability in the range 3.2–8.9% RSD in the mid-therapeutic window (100 ng/ml).  相似文献   

18.
The hollow fiber-based stirring extraction bar liquid–liquid microextraction was applied to the extraction of hormones, including 17-α-ethinylestradiol, 17-α-estradiol, estriol, 17-β-estradiol, estrone, 17-α-hydroxyprogesterone, medroxyprogesterone, progesterone and norethisterone acetate, in milk. The present method has the advantages of both hollow fiber-liquid phase microextraction and stirring bar sorptive extraction. The stirring extraction bar was used as both the stirring bar of microextraction, and extractor of the analytes, which can make extraction, clean-up and concentration be carried out in one step. When the extraction was completed, the stirring extraction bar was easy isolated from the extraction system with the magnet. Several experimental parameters, including the type of extraction solvent, the number of hollow stirring extraction bar, extraction time, stirring speed, ionic strength, and desorption conditions were investigated and optimized. The analytes in the extract were derived and determined by gas chromatography mass spectrometry. Under optimal experimental conditions, good linearity was observed in the range of 0.20–20.00 ng mL−1. The limits of detection and quantification were in the range of 0.02–0.06 ng mL−1 and 0.07–0.19 ng mL−1, respectively. The present method was applied to the analysis of milk samples, and the recoveries of analytes were in the range of 93.6–104.6% with the relative standard deviations ranging from 1.6% to 6.2% (n = 5). The results showed that the present method was a rapid and feasible method for the determination of hormones in milk samples.  相似文献   

19.
In this paper, a combined hollow fiber-based liquid three-phase microextraction and voltammetric method are applied for the first time as a highly selective and sensitive method of electrochemical analysis. Desipramine, used as a model compound was extracted from 8 mL aqueous solution (donor phase, 0.10 mol L−1 NaOH) through a thin phase of propyl benzoate inside the pores of a polypropylene hollow fiber and finally into a 10 μL acidic acceptor solution inside the hollow fiber. Three microelectrodes designed and constructed for the purposes of this study were placed into the two ends of the hollow fiber inside the acceptor solution, and voltammetric analysis was performed in-situ during the extraction. After 15 min, the final stable signal was used for analytical applications. Under the optimized conditions, an enrichment factor of 301 was achieved and the relative standard deviation (R.S.D.) of the method was 6.2% (n = 5). The calibration curve was obtained in the range of 5-5000 nmol L−1 with a reasonable linearity (R2 > 0.988) and the limit of detection (LOD) was found to be 0.8 nmol L−1. Finally, the applicability of the proposed method was evaluated by extraction and determination of desipramine in plasma and urine samples without any dilutions.  相似文献   

20.
Arpa Şahin C  Durukan I 《Talanta》2011,85(1):657-661
In this article, a new ligandless solidified floating organic drop microextraction (LL-SFODME) method has been developed for preconcentration of trace amount of cadmium as a prior step to its determination by flow injection-flame atomic absorption spectrometry (FI-FAAS). The methodology is based on the SFODME of cadmium with 1-dodecanol in the absence of chelating agent. Several factors affecting the microextraction efficiency, such as, pH, sodium dodecylbenzenesulfonate (SDBS) concentration, extraction time, stirring rate and temperature were investigated and optimized. Under optimized experimental conditions an enhancement factor of 205 was obtained for 100 mL of sample solution. The calibration graph was linear in the range of 1.0-25.0 ng mL−1, the limit of detection (3s) was 0.21 ng mL−1 and the limit of quantification (10s) was 0.62 ng mL−1. The relative standard deviation (RSD) for 10 replicate measurements of 10 ng mL−1 cadmium was 4.7%. The developed method was successfully applied to the extraction and determination of cadmium in standard and several water samples and satisfactory results were obtained.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号